3/2 solenoid poppet valve (directly actuated)cdn.norgren.com/pdf/cv_en_5_2_088_cv45.pdfcv45 3/2...

2
CV45 3/2 Solenoid Poppet Valve (Directly actuated) 10/16 en CV/en 5.2.088.01 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2016 - 5311b) © 2015 Norgren Ltd. Medium: Compressed air lubricated or non-lubricated Operation: Solenoid direct operated poppet valve - Normally Closed Inlet pressure: 5 ... 10 bar (72 ... 145 psi) Outlet pressure: 0 ... 10 bar (0 ... 145 psi) Orifice: 2 or 3 mm Port size: ø 14,3 mm nominal at 8 mm from port opening Exhaust port: IP 69 rating Operating temperature: 2 mm orifice -25 ... +125°C (-13 ... +257°F) 3 mm orifice -40 ... +85°C (-40 ... +185°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F) Materials: Valve base: PA glassfilled Coil: Copper wire Internal parts: Stainless steel Seals: NBR/FPM Technical features > Port size: Ø 14,3 mm > Temperature up to +125°C > Robust over-mould design > Suitable for use with push in cartridge fittings/blacking plugs accessories > TYCO HDSCS > IP 69 > Any orientation operation > Option to stack valves with use of O-ring accessory > Vibration to ISO 16750-3 (2007) > Example applications: Differential lock, energy brake, horn signal, axle lift etc. Technical data – solenoid operators Nominal voltages 24 V d.c. Duty cycle 100% ED Protection diodes 1 x freewheeling, 1 x reverse polarity Valve electrical connection mates with T.E. connector 1-1418448-2 1 Technical data - standard options Symbol Orifice (mm) Power consumption (24 V @ 20°C coil temperature) (W) No. of inserts Flow rate @ 6 bar (20°C) P1 to P2 (l/sec) With/ Without O-ring/ O-ring guard Weight (kg) Model 3 2 1 (1) + - (3) 3 ø 2 3,5 4 3 No 0,4 90-22327 ø 3 10 2 6 Yes 0,4 90-22368 ø 3 10 4 6 Yes 0,4 90-22338 ø 3 10 2 6 No 0,4 90-22296 ø 3 10 4 6 No 0,4 90-22295 1 O-ring accessory (90-21978)

Upload: others

Post on 25-Jun-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 3/2 Solenoid Poppet Valve (Directly actuated)cdn.norgren.com/pdf/CV_en_5_2_088_CV45.pdfCV45 3/2 Solenoid Poppet Valve (Directly actuated) 10/16 en CV/en 5.2.088.01 Our policy is one

CV45 3/2 Solenoid Poppet Valve (Directly actuated)

10/16en CV/en 5.2.088.01

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2016 - 5311b) © 2015 Norgren Ltd.

Medium:Compressed air lubricated or non-lubricatedOperation:Solenoid direct operated poppet valve - Normally ClosedInlet pressure:5 ... 10 bar (72 ... 145 psi)

Outlet pressure:0 ... 10 bar (0 ... 145 psi)Orifice:2 or 3 mmPort size:ø 14,3 mm nominal at 8 mm from port openingExhaust port:IP 69 rating

Operating temperature:2 mm orifice-25 ... +125°C (-13 ... +257°F)3 mm orifice-40 ... +85°C (-40 ... +185°F)Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Materials:Valve base: PA glassfilled Coil: Copper wire Internal parts: Stainless steel Seals: NBR/FPM

Technical features

> Port size: Ø 14,3 mm

> Temperature up to +125°C

> Robust over-mould design

> Suitable for use with push in cartridge fittings/blacking plugs accessories

> TYCO HDSCS

> IP 69

> Any orientation operation

> Option to stack valves with use of O-ring accessory

> Vibration to ISO 16750-3 (2007)

> Example applications: Differential lock, energy brake, horn signal, axle lift etc.

Technical data – solenoid operatorsNominal voltages 24 V d.c.

Duty cycle 100% ED

Protection diodes 1 x freewheeling, 1 x reverse polarity

Valve electrical connection mates with

T.E. connector 1-1418448-2

1

Technical data - standard optionsSymbol Orifice

(mm)Power consumption (24 V @ 20°C coil temperature) (W)

No. of inserts Flow rate @ 6 bar (20°C) P1 to P2 (l/sec)

With/ Without O-ring/ O-ring guard

Weight(kg)

Model

3

2

1 (1) + - (3) 3

ø 2 3,5 4 3 No 0,4 90-22327

ø 3 10 2 6 Yes 0,4 90-22368

ø 3 10 4 6 Yes 0,4 90-22338

ø 3 10 2 6 No 0,4 90-22296

ø 3 10 4 6 No 0,4 90-22295

1 O-ring accessory (90-21978)

Page 2: 3/2 Solenoid Poppet Valve (Directly actuated)cdn.norgren.com/pdf/CV_en_5_2_088_CV45.pdfCV45 3/2 Solenoid Poppet Valve (Directly actuated) 10/16 en CV/en 5.2.088.01 Our policy is one

CV45 3/2 Solenoid Poppet Valve (Directly actuated)

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2016 - 5311b) © 2015 Norgren Ltd.en CV/en 5.2.088.02

10/16

Dimensions Valve

Straight adaptor A1329-06N

Adaptor/plug assembly instruction (assembly tools are available on request)For guidance only!

Straight adaptor A1221-01

Blanking plug A1221-03 Elbow adaptor A1329-06

Use as single or stackable optionsOption 1: Use single valve. need to use blank plug (push in) accessory for

one of inlet ports.Option 2: Use as stacked together, need to use O-ring accessory to allow

seal plus pushing in fitting accessories including blanking plug.

Dimensions in mm Projection/First angle

42,5

47,5 71,5

24

2516

89,5

68

22,5

4

5

3

11 2

1 Inlet port x 2 (use either inlet port + use blanking plug in other)2 Outlet port 3 Exhaust port 4 Threaded inserts M6 x9,5 deep 5 Stacked option pitch dimension

6 Pressing tool (not in scope of delivery)7 Adaptor or plug 8 Press flush 9 Valve housing

AccessoriesO-ring Straight adaptor Elbow adaptor

For ø 6 x 1 mm Tube

Blanking plug

90-21978 A1329-06N (ø 6 x 1 mm tube) A1329-06 A1221-03

A1221-01 (ø 8 x 1 mm tube)

ø8 14,5

ø21 32

14,5ø19

17

ø6 14,5

ø19 29

ø19

ø20

22

29

19,3

4,5

14,5

6

7

67

8 8

99

Press down

Press downAssembly tool for elbow adaptor

8,2 ±0,15

17

>19,

3

>ø20

14,3 ±0,15

7,6

±0,1

5

Fitting details for guidance Please refer to the fitting data sheets en 9.1.068 for details

Warning

These products are intended for use in Commercial Vehicle transport systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features/data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI Precision Engineering, Norgren Ltd.

Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products.