solutions for cisco access points oberoninc2017/06/25  · solutions for cisco access points...

240
1 Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877) 867-2312 www.oberoninc.com 6-25-2017

Upload: others

Post on 21-Sep-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

1

Solutions for Cisco Access Points oberoninc.com

Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877) 867-2312 www.oberoninc.com

6-25-2017

Page 2: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Table of Contents

4 Welcome to Oberon

5 Finding the Perfect Enclosure

Suspended Ceiling Enclosures with Doors6 1046-MR Suspended Ceiling AP Mount; Door For Meraki APs8 1046-MR-T Suspended Ceiling AP Mount; Door For Meraki APs

10 1047-CCOAP Suspended Ceiling Enclosure/Cisco APs12 1047-CCOAP3800 Suspended Ceiling Enclosure/Cisco APs14 1047-CCOAP3800-T Suspended Ceiling Enclosure/Cisco APs16 1047-CCOAP-T Suspended Ceiling Enclosure/Cisco APs18 1047-HLA Suspended Ceiling Enclosure/Cisco Hyperlocation Antenna20 1047-HLA-T Suspended Ceiling Enclosure/Cisco Hyperlocation Antenna22 1047-LPDOME Suspended Ceiling AP Enclosure; Low-Profile ABS Dome24 1047-LPDOME-T Suspended Ceiling AP Enclosure; Low-Profile ABS Dome26 1052-00 4.5" Deep Suspended Ceiling Enclosure To 7 Antennas28 1052-CCOANT 4.5" Deep Suspended Ceiling Enclosure - Cisco Antenna30 1052-CCOAP 4.5" Deep Suspended Ceiling Enclosure - Cisco APs32 1052-CCOAP3800 4.5" Deep Suspended Ceiling Enclosure - Cisco 3800 APs34 1052-XXX-CCEA 4.5" Deep Suspended Ceiling Enclosure36 1075-CCOAP Suspended Ceiling AP Enclosure-Tile Cutout/Cisco APs38 1075-CP Suspended Ceiling AP Enclosure-Tile Cutout/Clear Dome40 1075-WA Suspended Ceiling AP Enclosure-Tile Cutout/ABS Dome42 1077-CCOAP3800 Suspended Ceiling Wap Mount; Door: Cisco 3800S44 1077-CCOAP3800-T Suspended Ceiling Wap Mount; Door: Cisco 3800S46 1077-CCOAP-T 3" Deep Suspended Ceiling Zone Enclosure-Cisco AP48 1077-CCOAP 3" Deep Suspended Ceiling Zone Enclosure-Cisco AP50 1077-CP 3" Deep Suspended Ceiling Zone Enclosure-Clear Dome52 1077-CP-T 3" Deep Suspended Ceiling Zone Enclosure-Clear Dome54 1077-WA 3" Deep Suspended Ceiling Zone Enclosure-ABS Dome56 1077-WA-T 3" Deep Suspended Ceiling Zone Enclosure-ABS Dome

Suspended Ceiling Mounts58 1040-CCOAP Cloud Or Canopy Ceiling AP Installation Kit-Cisco60 1040-CCOAP3800 Cloud Or Canopy Ceiling AP Installation Kit-Cisco62 1044-CCOAP-B AP Mount Tile Bridge W/Back-Box - Cisco APs64 1045-00 Above-Ceiling AP Mount66 1064-00 Suspended Ceiling Locking Mount-Cisco APs68 1064-T Suspended Ceiling Locking Mount-Cisco APs, Tegular

Right-Angle Brackets70 1006-CCOAP Right-Angle AP Wall Bracket For Cisco APs71 1006-CCOAP3800 Right-Angle Wap Wall Bracket For Cisco 2800/3800 Series APs73 1006-HLA Right-Angle Wap Wall Bracket For Cisco AP With Hyperlocation Antenna74 1008-AP3800-COVER Right-Angle AP Joist Or Wall Bracket With Black Vanity Cover For Cisco 3800 Series76 1008-AP-COVER Right-Angle AP Joist Or Wall Bracket With Black Vanity Cover For Most Vendors’ APs78 1008-HLA-COVER Right-Angle AP Joist Or Wall Bracket With Black Vanity Cover For Cisco AP And Hla Antenna80 1008-MR-COVER Right-Angle AP Joist Or Wall Bracket With Black Vanity Cover For Meraki Mr32,34, 42, And Other APs82 1009-00 Economy Universal Right-Angle AP Wall Bracket: White84 1010-00 Right-Angle AP Mount With Universal T-Bar Bracket, No Cover86 1011-00 Right-Angle AP Mount With Universal T-Bar Bracket And Cover88 1012-00 Right-Angle AP Mount With Universal T-Bar Bracket And Locking Cover

Surface Mount Enclosures89 900-00 Surface Wall Mount Box For Wireless Access Points90 900-HC Hanging Conduit Or Pendant Mount Box For APs91 1013-00 2-Axis Articulating AP/Antenna Mount93 1013-COVER 2-Axis Articulating AP/Antenna Mount: White Cover95 1014-00 1-Axis Articulating AP/Antenna Mount: White Cover97 1015-00 11" ABS AP Lock-Box: Solid Door99 1015-C 11" ABS AP Lock-Box: T-Bar, Translucent Door

101 1016-00 18" Polycarbonate AP Lock-Box: Solid Door103 1016-ANTPLATE 18" Polycarbonate AP Lock-Box: Solid Door With Articulating Antenna Bracket105 1016-C 18" Polycarbonate AP Lock-Box: T-Bar, Translucent Door107 1017-BL Small Wall Mount Wap Protective Non-Metallic Box109 1017-WH Small Wall Mount AP Protective Non-Metallic Box111 1018-WH Wall Mount, Polycarbonate AP Enclosure113 1030-00 Steel Surface Mount AP Wall Enclosure-ABS Dome

Wall and Hard Ceiling - Recess Mount115 1042-CCOAP Recessed Ceiling AP Install Kit- Old Construction117 1042-CCOAP3800 Recessed Ceiling AP Install Kit- Old Construction

Page 3: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

119 1042-FL Recessed Hard Ceiling AP Installation Kit121 1043-CCOAP Recessed Ceiling AP Install Kit- New Construction123 1043-CCOAP3800 Recessed Ceiling AP Install Kit- New Construction125 1051-00 Recessed Ceiling/Wall AP Mount127 1051-CCOANT Recessed Ceiling/Wall AP Mount - Cisco Antenna129 1051-CCOAP Recessed Ceiling/Wall AP Mount - Cisco APs131 1051-CCOAP3800 Recessed Ceiling/Wall AP Mount - Cisco 3800 APs133 1051-DOME Recessed Ceiling/Wall AP Mount- ABS Dome135 1051-XXX-CCEA Recessed Ceiling/Wall AP Mount137 1065-CCOAP Hard Ceiling Locking Mount-Cisco APs139 1076-CCOAP 3" Deep Recessed AP Wall Mount-Cisco AP141 1076-CP 3" Deep Recessed AP Wall Mount-Clear Dome143 1076-WA 3" Deep Recessed AP Wall Mount-White ABS Dome

Indoor/Outdoor NEMA145 1020-00 Polycarbonate NEMA 4 AP Enclosure:Screw-On Cover147 1020-RAB NEMA 4 AP Enclosure:Screw-On Cover, Right-Angle149 1020-RAB-PMK NEMA 4 Wap Enclosure:Screw-On Cover, Right-Angle151 1024-00 Polycarbonate NEMA 4 AP Enclosure-Solid Door153 1024-C Polycarbonate NEMA 4 AP Enclosure-Clear Door155 1026-00 Polycarbonate NEMA4 Wifi AP Box-12X10X6 Solid Door157 1026-864 Polycarbonate NEMA4 Wifi AP Box-8X6X4 Solid Door159 1026-864-C Polycarbonate NEMA4 Wifi AP Box-8X6X4 Clear Door161 1026-1084 Polycarbonate NEMA4 Wifi AP Box-10X8X4 Solid Door163 1026-1084-C Polycarbonate NEMA4 Wifi AP Box-10X8X4 Clear Door165 1026-14126 Polycarbonate NEMA4 Wifi AP Box-14X12X6 Solid Door167 1026-14126-C Polycarbonate NEMA4 Wifi AP Box-14X12X6 Clear Door169 1026-16148 Polycarbonate NEMA4 Wifi AP Box-16X14X8 Solid Door171 1026-16148-C Polycarbonate NEMA4 Wifi AP Box-16X14X8 Clear Door173 1026-242410 Polycarbonate NEMA4 Wifi AP Box-24X24X10 Solid Door175 1026-242410-C Polycarbonate NEMA4 Wifi AP Box-24X24X10 Clear Door177 1026-C Polycarbonate NEMA4 Wifi AP Box-12X10X6 Clear Door179 1028-04-ANT5-B Aluminum NEMA4 AP Enclosure:4" Deep Recessed181 1028-04-ANT5-F Aluminum NEMA4 AP Enclosure:4" Deep Suspended Ceiling183 1028-08-ANT5-B Aluminum NEMA4 AP Enclosure:8" Deep Recessed185 1028-08-ANT5-F Aluminum NEMA4 AP Enclosure:8" Deep Suspended Ceiling187 3010 Stadium Underseat Enclosure For APs189 3015-WE Underseat Wap/Antenna Enclosure; Wide190 3020 Handrail Wap/Antenna Enclosure

Suspended Ceiling Zone Enclosures191 1074-04-ANT7 2U Suspended Ceiling Zone Enclosure-Up To 7 Antennas193 1074-04-DOME 3U Suspended Ceiling Zone Enclosure-Ventilated, Beveled195 1074-04-VENT 3U Suspended Ceiling Zone Enclosure-Ventilated, Beveled197 1074-06-ANT7 3U Suspended Ceiling Zone Enclosure-Up To 7 Antennas199 1074-06-DOME 3U Suspended Ceiling Zone Enclosure-Ventilated, Beveled201 1074-06-VENT 4U Suspended Ceiling Zone Enclosure-Ventilated, Beveled

WAP Vanity Covers203 33-ANT-COVER Paintable Antenna Vanity Cover- White ABS204 33-AP3800-COVER Indoor Wap Vanity Cover- Black ABS205 33-AP-COVER206 33-HLA-COVER Indoor Cisco Hla Antenna/AP Vanity Cover-Black ABS207 33-IW3700-COVER Wap Vanity Cover For Cisco IW3700208 33-MR-COVER Indoor Meraki AP Vanity Cover- Black ABS

209 Retrofit Doors and Trims for Oberon Enclosures

Accessories229 39-1008-SPKRMNT U-Bolt Bracket Assembly For The Model 1008/1009 Series230 39-1015-PLATE Model 1015 Metal Back Plate231 39-1016-ANTPLATE Articulating Antenna Mount For Oberon Model 1016 Series232 39-1016-SPKRMNT Mounting Bracket Assembly For The Model 1016 Series233 39-1020-PMK Pole Mount Kit For Oberon Model 1020-RAB234 39-1790-INTERLOCK Poe Interlock Switch - Disables AP On Door Open235 39-HLA-PLATE Bracket Accessory For Cisco Hyperlocation Antenna

How to Buy Oberon Products236 Custom Enclosures

Warranty237 Appendix A – Industry Compliance Assurance238 Appendix B – Oberon’s National Electric Code Paragraphs Compliance Statement239 Appendix C – Warranty

Page 4: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Welcome to Oberon ABOUT Since 1999, Oberon, Inc. has been providing WiFi infrastructure solutions to wireless consultants, integrators, installers, and end users. Oberon's wireless access point mounting solutions and enclosures are used where the wireless coverage, infrastructure security, environmental robustness, aesthetics, and serviceability are paramount in the network design and implementation. Oberon offers the widest variety of ceiling, wall, outdoor, and challenging environment mounting solutions for Wi-Fi access points from all leading wireless vendors. Oberon's installation solutions have helped thousands of wireless professionals in the global healthcare, government, transportation and logistics, education, retail, hospitality, and manufacturing achieve optimum mobile network performance. SOLUTIONS WIFI ACCESS POINT MOUNTING SOLUTIONS FOR VIRTUALLY EVERY ENVIRONMENT Conventional Carpeted Office Spaces and Classrooms

Suspended Ceiling tile replacement enclosure Recess mounts for suspended and cloud ceilings Recess mounts and surface mounts for drywall hard ceiling (old and new construction)

Other Building Construction

Recess mounts for plaster and lathe and other difficult ceiling construction Surface mount lock-boxes for APs and antennas

Indoor High Density WiFi (auditoriums and meeting areas)

Right-angle wall brackets Articulating antenna and AP mounts Under-seat thermoformed plastic enclosures

Outdoor Sports Venues and Other Outdoor Environments

Low-profile, thermoformed plastic AP and antenna enclosures Under-seat thermoformed plastic enclosures Plastic NEMA 4 enclosures WiFi bollards

OBERON’S PRODUCTS FACILITATE THE WIRELESS CONSULTANT, NETWORK DESIGNER, AND INSTALLER IN PROVIDING THE BEST PROFESSIONAL INSTALLATION

UL listed for code compliance in plenum installation OSHPD approval and drawing for seismic anchorage Ceiling enclosures simplify ICRA procedure compliance in hospitals Locking enclosures provide HIPPA compliance in hospitals and PCI compliance in retail environments Aesthetics in architecturally sensitive areas Products designed in collaboration with AP vendors to optimize wireless performance Reduced or simplified installation times

© 2017 Oberon, Inc. Copyright. All Rights Reserved. All text, images, graphics, and other materials contained in this catalog are subject to the copyright and other intellectual property rights of Oberon, Inc. These materials may not be reproduced, distributed, modified or reposted to other websites without the express written permission of Oberon, Inc. Images and documents may depict similar models in the product series. Readers are encouraged to visit oberoninc.com for the latest product spec sheets.

Since 1999, Oberon has been a leader in manufacturing solutions for conveniently installing and securing wireless network components

4

Page 5: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Finding the Perfect Enclosure for Your Wireless Access Point

The fastest, easiest way to locate enclosures for your specific wireless access point is to use the Enclosure Finder located on most pages of the website.

Simply enter the name of your AP’s vendor, and then select the model from the options in the dropdown box.

About the Results

The Enclosure Finder locates the most popular and recommended enclosures for specific access point models.

Need More Options?

If you have any questions, don’t see your AP, or want to explore more solutions, please contact:

Oberon Sales Department: [email protected] 1-877-867-2312

We’ll be happy to discuss all compatible solutions or the option of a custom design.

The Enclosure Finder is located on the Oberon homepage at oberoninc.com.

It can also be found in the sidebar on most other pages.

5

Page 6: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1046-MRSusp Ceiling AP Mount; Door for Meraki APs

Category: Suspended Ceiling Enclosures with Doors

Economical, locking 2' x 2' suspended ceiling tile enclosure mounts and securesAPs flush to the ceiling. The interchangeable door simplifies access point andantenna moves, adds, and changes without lifting ceiling tiles. Access points canbe mounted in the door or inside the enclosure with the configurations with theABS dome. “-T” version matches tegular ceiling tiles used in recessed grids.Specify –T version for professional, aesthetic installation in recessed gridceilings.Patent pending

Features & BenefitsEconomical 2’ x 2’ locking ceiling tile enclosure secures wireless access points from most vendorsAttractive, textured, powder-coat finish matches many ceilingsInterchangeable doors permit simple migration to new access points and antennasEnclosure back-box is an effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: Economical ceiling tile enclosure designed for wireless access points with integrated antennas. Access point mounts ininterchangeable door. Fits into standard 2’ x 2’ (U.S.) ceiling grid. Door designed for Meraki 32/34/42 APs.Performance: UL Listed for low-voltage applications, and designed to meet NEC300-22 and 300-23 for plenum installations.OSHPD approved, OPM-0110-13. De-rate AP operating temperature range by 10°C when mounted in enclosure.Locking, quick release interchangeable door for migration to other access pointsFirestop grommet for insertion into back-box, large enough for 2 Cat6A cables1” trade size knockouts in four wallsConstruction: 20 ga. galvanized steel back-box; 18 ga. white, powder-coated steel flange and door; solid back-box fills openingbehind access point, creating an effective fire, smoke, and dust barrier to simplify ICRA complianceEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsSize: 23.75 inches by 23.75 inches by 3 inches (603 mm by 603 mm by 76mm); back-box is 12.5 inches by 12.5 inches x 3 inches

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 3 in.• Item Weight: 13 lbs.• Shipping Weight: 17 lbs.

6

Page 7: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Dual Cable Egress Firestop Kit (1” trade size conduit connector and firestop grommet)(2) Keys for lock(4) Hanger wiresInstallation instructions

Available Accessories39-1790-INTERLOCK - PoE Interlock Switch - Disables AP on door open

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2677&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Oberon_Model_1046-MR_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Oberon_Model_1046-MR_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

7

Page 8: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1046-MR-TSusp Ceiling AP Mount; Door for Meraki APs

Category: Suspended Ceiling Enclosures with Doors

Economical, locking 2' x 2' suspended ceiling tile enclosure mounts and securesAPs flush to the ceiling. The interchangeable door simplifies access point andantenna moves, adds, and changes without lifting ceiling tiles. Access points canbe mounted in the door or inside the enclosure with the configurations with theABS dome. “-T” version matches tegular ceiling tiles used in recessed grids.Specify –T version for professional, aesthetic installation in recessed gridceilings.Patent pending

Features & BenefitsEconomical 2’ x 2’ locking ceiling tile enclosure secures wireless access points from most vendorsAttractive, textured, powder-coat finish matches many ceilingsInterchangeable doors permit simple migration to new access points and antennasEnclosure back-box is an effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: Economical ceiling tile enclosure designed for wireless access points with integrated antennas. Access point mounts ininterchangeable door. Fits into standard 2’ x 2’ (U.S.) ceiling grid. Door designed for Meraki 32/34/42 APs.Performance: UL Listed for low-voltage applications, and designed to meet NEC300-22 and 300-23 for plenum installations.OSHPD approved, OPM-0110-13. De-rate AP operating temperature range by 10°C when mounted in enclosure.Locking, quick release interchangeable door for migration to other access pointsFirestop grommet for insertion into back-box, large enough for 2 Cat6A cables1” trade size knockouts in four wallsConstruction: 20 ga. galvanized steel back-box; 18 ga. white, powder-coated steel flange and door; solid back-box fills openingbehind access point, creating an effective fire, smoke, and dust barrier to simplify ICRA complianceEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsSize: 23.75 inches by 23.75 inches by 3 inches (603 mm by 603 mm by 76mm); back-box is 12.5 inches by 12.5 inches x 3 inches

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 3 in.• Item Weight: 13 lbs.• Shipping Weight: 17 lbs.

8

Page 9: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Dual Cable Egress Firestop Kit (1” trade size conduit connector and firestop grommet)(2) Keys for lock(4) Hanger wiresInstallation instructions

Available Accessories39-1790-INTERLOCK - PoE Interlock Switch - Disables AP on door open

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2668&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Oberon_Model_1046-MR-T_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Oberon_Model_1046-MR-T_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

9

Page 10: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1047-CCOAPSusp Ceiling Enclosure/Cisco APs

Category: Suspended Ceiling Enclosures with Doors

Locking, 2' x 2' suspended ceiling tile enclosure mounts and secures wirelessaccess point and DAS remote units with non-detachable or internal antennas.This steel enclosure replaces a standard ceiling tile, and its larger back-box issuitable for larger access points and antennas. The interchangeable doorsimplifies access point and antenna changes. Access points can be mounted inthe door or inside the enclosure with the configurations with the dome.Patent pending

Features & BenefitsAttractive, textured, powder-coat finish matches many ceilingsLarger back-box designed for securing most vendors' enterprise APs and DAS remotesInterchangeable doors permit simple migration to new APs and antennasEnclosure back-box is an effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: Economical ceiling tile enclosure designed for APs with integrated antennas. Fits into standard 2' x 2' (U.S.) ceiling grid.Door designed for Cisco APs.Performance: UL listed for low-voltage applications, and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPDapproved, OPM-0110-13. De-rate AP operating temperature range by 6°C when mounted in enclosure.Locking, quick-release, interchangeable door for migration to other APs; large door permits migration to large APs and domesFirestop grommet for insertion into back-box, large enough for 2 Cat6A cables1" trade size knockouts in four wallsConstruction: 20 ga. galvanized steel back-box. 18 ga. white, powder-coated steel flange and door. Solid back-box fills openingbehind AP, creating an effective fire, smoke and dust barrier to simplify ICRA compliance.Enclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate "–T" for tegular flange unitsSize: 23.75 inches by 23.75 inches by 3 inches (603 mm by 603 mm by 76mm); back-box is 18.5" by 18.5" x 3"

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 3 in.• Item Weight: 16 lbs.• Shipping Weight: 20 lbs.

10

Page 11: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Dual Cable Egress Firestop Kit (1" trade size conduit connector and firestop grommet)(2) Keys for lock(4) Hanger wiresInstallation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2837&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1047-CCOAP_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1047-XX_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

11

Page 12: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1047-CCOAP3800Susp Ceiling Enclosure/Cisco APs

Category: Suspended Ceiling Enclosures with Doors

Locking, 2' x 2' suspended ceiling tile enclosure mounts and secures wirelessaccess point and DAS remote units with non-detachable or internal antennas.This steel enclosure replaces a standard ceiling tile, and its larger back-box issuitable for larger access points and antennas. The interchangeable doorsimplifies access point and antenna changes. Access points can be mounted inthe door or inside the enclosure with the configurations with the dome.Patent pending

Features & BenefitsAttractive, textured, powder-coat finish matches many ceilingsLarger back-box designed for securing most vendors' enterprise wireless access points and DAS remotesInterchangeable doors permit simple migration to new access points and antennasEnclosure back-box is an effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: Economical ceiling tile enclosure designed for wireless access points with integrated antennas. Fits into standard 2’ x 2’(U.S.) ceiling grid. Door designed for Cisco 2800 and 3800 APs.Performance: UL listed for low-voltage applications, and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPDapproved, OPM-0110-13. De-rate AP operating temperature range by 6°C when mounted in enclosure. Locking, quick-release, interchangeable door for migration to other access points; large door permits migration to large accesspoints and domesFirestop grommet for insertion into back-box, large enough for 2 Cat6A cables1” trade size knockouts in four wallsConstruction: 20 ga. galvanized steel back-box. 18 ga. white, powder-coated steel flange and door. Solid back-box fills openingbehind access point, creating an effective fire, smoke and dust barrier to simplify ICRA compliance.Enclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wire.Maximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsSize: 23.75 inches by 23.75 inches by 3 inches (603 mm by 603 mm by 76mm); back-box is 18.5” by 18.5” x 3”

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 3 in.• Item Weight: 16 lbs.• Shipping Weight: 20 lbs.

12

Page 13: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Dual Cable Egress Firestop Kit (1” trade size conduit connector and firestop grommet)(2) Keys for lock(4) Hanger wiresInstallation instructions

Videos - https://www.youtube.com/user/oberoninc1047-CCOAP3800 Installation Video View at https://youtu.be/6P-QvSbHvzw

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2964&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1047-CCOAP_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1047-XX_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

13

Page 14: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1047-CCOAP3800-TSusp Ceiling Enclosure/Cisco APs

Category: Suspended Ceiling Enclosures with Doors

Locking, 2' x 2' suspended ceiling tile enclosure mounts and secures wirelessaccess point and DAS remote units with non-detachable or internal antennas.This steel enclosure replaces a standard ceiling tile, and its larger back-box issuitable for larger access points and antennas. The interchangeable doorsimplifies access point and antenna changes. Access points can be mounted inthe door or inside the enclosure with the configurations with the dome.Patent pending

Features & Benefits

Attractive, textured, powder-coat finish matches many ceilingsLarger back-box designed for securing most vendors' enterprise wireless access points and DAS remotesInterchangeable doors permit simple migration to new access points and antennasEnclosure back-box is an effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: Economical ceiling tile enclosure designed for wireless access points with integrated antennas. Fits into standard 2’ x 2’(U.S.) ceiling grid. Door designed for Cisco 2800 and 3800 APs.Performance: UL listed for low-voltage applications, and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPDapproved, OPM-0110-13. De-rate AP operating temperature range by 6°C when mounted in enclosure. Locking, quick-release, interchangeable door for migration to other access points; large door permits migration to large accesspoints and domesFirestop grommet for insertion into back-box, large enough for 2 Cat6A cables1” trade size knockouts in four wallsConstruction: 20 ga. galvanized steel back-box. 18 ga. white, powder-coated steel flange and door. Solid back-box fills openingbehind access point, creating an effective fire, smoke and dust barrier to simplify ICRA compliance.Enclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wire.Maximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsSize: 23.75 inches by 23.75 inches by 3 inches (603 mm by 603 mm by 76mm); back-box is 18.5” by 18.5” x 3”

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 3 in.• Item Weight: 16 lbs.• Shipping Weight: 20 lbs.

14

Page 15: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Dual Cable Egress Firestop Kit (1” trade size conduit connector and firestop grommet)(2) Keys for lock(4) Hanger wiresInstallation instructions

Videos - https://www.youtube.com/user/oberoninc1047-CCOAP3800 Installation Video View at https://youtu.be/6P-QvSbHvzw

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2971&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1047-CCOAP3800-T_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1047-XX_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

15

Page 16: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1047-CCOAP-TSusp Ceiling Enclosure/Cisco APs

Category: Suspended Ceiling Enclosures with Doors

Locking, 2' x 2' suspended ceiling tile enclosure mounts and secures wirelessaccess point and DAS remote units with non-detachable or internal antennas.This steel enclosure replaces a standard ceiling tile, and its larger back-box issuitable for larger access points and antennas. The interchangeable doorsimplifies access point and antenna changes. Access points can be mounted inthe door or inside the enclosure with the configurations with the dome.Patent pending

Features & BenefitsAttractive, textured, powder-coat finish matches many ceilingsLarger back-box designed for securing most vendors' enterprise wireless access points and DAS remotesInterchangeable doors permit simple migration to new access points and antennasEnclosure back-box is an effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: Economical ceiling tile enclosure designed for wireless access points with integrated antennas. Fits into standard 2’ x 2’(U.S.) ceiling grid. Door designed for Cisco APs.Performance: UL listed for low-voltage applications, and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPDapproved, OPM-0110-13. De-rate AP operating temperature range by 6°C when mounted in enclosure. Locking, quick-release, interchangeable door for migration to other access points; large door permits migration to large accesspoints and domesFirestop grommet for insertion into back-box, large enough for 2 Cat6A cables1” trade size knockouts in four wallsConstruction: 20 ga. galvanized steel back-box. 18 ga. white, powder-coated steel flange and door. Solid back-box fills openingbehind access point, creating an effective fire, smoke and dust barrier to simplify ICRA compliance.Enclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsSize: 23.75 inches by 23.75 inches by 3 inches (603 mm by 603 mm by 76mm); back-box is 18.5” by 18.5” x 3”

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 3 in.• Item Weight: 16 lbs.• Shipping Weight: 20 lbs.

16

Page 17: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Dual Cable Egress Firestop Kit (1” trade size conduit connector and firestop grommet)(2) Keys for lock(4) Hanger wiresInstallation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2842&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1047-CCOAP-T_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1047-XX_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

17

Page 18: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1047-HLASusp Ceiling Enclosure/Cisco Hyperlocation Antenna

Category: Suspended Ceiling Enclosures with Doors

Locking, 2' x 2' suspended ceiling tile enclosure mounts and secures wirelessaccess point and DAS remote units with non-detachable or internal antennas.This steel enclosure replaces a standard ceiling tile, and its larger back-box issuitable for larger access points and antennas. The interchangeable doorsimplifies access point and antenna changes. Access points can be mounted inthe door or inside the enclosure with the configurations with the dome.Patent pending

Features & Benefits

Attractive, textured, powder-coat finish matches many ceilingsLarger back-box designed for securing most vendors' enterprise wireless access points and DAS remotesInterchangeable doors permit simple migration to new access points and antennasEnclosure back-box is an effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: Economical ceiling tile enclosure designed for wireless access points with integrated antennas. Access point mounts ininterchangeable door. Fits into standard 2’ x 2’ (U.S.) ceiling grid.Performance: UL Listed for low-voltage applications, and designed to meet NEC300-22 and 300-23 for plenum installations.OSHPD approved, OPM-0110-13. De-rate AP operating temperature range by 6°C when mounted in enclosure.Locking, quick release interchangeable door for migration to other access pointsFirestop grommet for insertion into back-box, large enough for 2 Cat6A cables1” trade size knockouts in four wallsConstruction: 20 ga. galvanized steel back-box; 18 ga. white, powder-coated steel flange and door; solid back-box fills openingbehind access point, creating an effective fire, smoke, and dust barrier to simplify ICRA complianceEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsAP max. operating temperature should be de-rated by 6° C inside the enclosureSize: 23.75 inches by 23.75 inches by 3 inches (603 mm by 603 mm by 76mm); back-box is 18.5” by 18.5” x 3”.

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 3 in.• Item Weight: 16 lbs.• Shipping Weight: 20 lbs.

18

Page 19: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Dual Cable Egress Firestop Kit (1” trade size conduit connector and firestop grommet)(2) Keys for lock(4) Hanger wiresInstallation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2264&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1047-HLA_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1047-XX_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

19

Page 20: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1047-HLA-TSusp Ceiling Enclosure/Cisco Hyperlocation Antenna

Category: Suspended Ceiling Enclosures with Doors

Locking, 2' x 2' suspended ceiling tile enclosure mounts and secures wirelessaccess point and DAS remote units with non-detachable or internal antennas.This steel enclosure replaces a standard ceiling tile, and its larger back-box issuitable for larger access points and antennas. The interchangeable doorsimplifies access point and antenna changes. Access points can be mounted inthe door or inside the enclosure with the configurations with the dome.Patent pending

Features & BenefitsAttractive, textured, powder-coat finish matches many ceilingsLarger back-box designed for securing most vendors' enterprise wireless access points and DAS remotesInterchangeable doors permit simple migration to new access points and antennasEnclosure back-box is an effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: Economical ceiling tile enclosure designed for wireless access points with integrated antennas. Access point mounts ininterchangeable door. Fits into standard 2’ x 2’ (U.S.) ceiling grid.Performance: UL Listed for low-voltage applications, and designed to meet NEC300-22 and 300-23 for plenum installations.OSHPD approved, OPM-0110-13. De-rate AP operating temperature range by 6°C when mounted in enclosure.Locking, quick release interchangeable door for migration to other access pointsFirestop grommet for insertion into back-box, large enough for 2 Cat6A cables1” trade size knockouts in four wallsConstruction: 20 ga. galvanized steel back-box; 18 ga. white, powder-coated steel flange and door; solid back-box fills openingbehind access point, creating an effective fire, smoke, and dust barrier to simplify ICRA complianceEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsAP max. operating temperature should be de-rated by 6° C inside the enclosureSize: 23.75 inches by 23.75 inches by 3 inches (603 mm by 603 mm by 76mm); back-box is 18.5” by 18.5” x 3”.

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 3 in.• Item Weight: 16 lbs.• Shipping Weight: 20 lbs.

20

Page 21: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Dual Cable Egress Firestop Kit (1” trade size conduit connector and firestop grommet)(2) Keys for lock(4) Hanger wiresInstallation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2399&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1047-HLA-T_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1047-XX_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

21

Page 22: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1047-LPDOMESusp Ceiling AP Enclosure; low-profile ABS dome

Category: Suspended Ceiling Enclosures with Doors

Locking, 2' x 2' suspended ceiling tile enclosure mounts and secures wirelessaccess point and DAS remote units with non-detachable or internal antennas.This steel enclosure replaces a standard ceiling tile, and its larger back-box issuitable for larger access points and antennas. The interchangeable doorsimplifies access point and antenna changes. Access points can be mounted inthe door or inside the enclosure with the configurations with the dome.Patent pending

Features & Benefits

Attractive, textured, powder-coat finish matches many ceilingsLarger back-box designed for securing most vendors' enterprise wireless access points and DAS remotesInterchangeable doors permit simple migration to new access points and antennasEnclosure back-box is an effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: Economical ceiling tile enclosure designed for wireless access points with integrated antennas. Access point mounts ininterchangeable door. Fits into standard 2’ x 2’ (U.S.) ceiling grid. Plastic dome in door, suitable for most vendors’ APs. Performance: UL Listed for low-voltage applications, and designed to meet NEC300-22 and 300-23 for plenum installations.OSHPD approved, OPM-0110-13. De-rate AP operating temperature range by 6°C when mounted in enclosure. Locking, quick release interchangeable door for migration to other access pointsFirestop grommet for insertion into back-box, large enough for 2 Cat6A cables1” trade size knockouts in four wallsConstruction: 20 ga. galvanized steel back-box; 18 ga. white, powder-coated steel flange and door. UL-94-5VA white ABS plasticdome; solid back-box fills opening behind access point, creating an effective fire, smoke, and dust barrier to simplify ICRAcomplianceEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsAP max. operating temperature should be de-rated by 6° C inside the enclosureSize: 23.75 inches by 23.75 inches by 3 inches (603 mm by 603 mm by 76mm); back-box is 18.5” by 18.5” x 3”; total depth is 5”.

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 3 in.• Item Weight: 16 lbs.• Shipping Weight: 20 lbs. 22

Page 23: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Dual Cable Egress Firestop Kit (1” trade size conduit connector and firestop grommet)(2) Keys for lock(4) Hanger wiresInstallation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2252&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1047-LPDOME_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1047-XX_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

23

Page 24: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1047-LPDOME-TSusp Ceiling AP Enclosure; low-profile ABS dome

Category: Suspended Ceiling Enclosures with Doors

Locking, 2' x 2' suspended ceiling tile enclosure mounts and secures wirelessaccess point and DAS remote units with non-detachable or internal antennas.This steel enclosure replaces a standard ceiling tile, and its larger back-box issuitable for larger access points and antennas. The interchangeable doorsimplifies access point and antenna changes. Access points can be mounted inthe door or inside the enclosure with the configurations with the dome.Patent pending

Features & Benefits

Attractive, textured, powder-coat finish matches many ceilingsLarger back-box designed for securing most vendors' enterprise wireless access points and DAS remotesInterchangeable doors permit simple migration to new access points and antennasEnclosure back-box is an effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: Economical ceiling tile enclosure designed for wireless access points with integrated antennas. Access point mounts ininterchangeable door. Fits into standard 2’ x 2’ (U.S.) ceiling grid. Plastic dome in door, suitable for most vendors’ APs. Performance: UL Listed for low-voltage applications, and designed to meet NEC300-22 and 300-23 for plenum installations.OSHPD approved, OPM-0110-13. De-rate AP operating temperature range by 6°C when mounted in enclosure. Locking, quick release interchangeable door for migration to other access pointsFirestop grommet for insertion into back-box, large enough for 2 Cat6A cables1” trade size knockouts in four wallsConstruction: 20 ga. galvanized steel back-box; 18 ga. white, powder-coated steel flange and door. UL-94-5VA white ABS plasticdome; solid back-box fills opening behind access point, creating an effective fire, smoke, and dust barrier to simplify ICRAcomplianceEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsAP max. operating temperature should be de-rated by 6° C inside the enclosureSize: 23.75 inches by 23.75 inches by 3 inches (603 mm by 603 mm by 76mm); back-box is 18.5” by 18.5” x 3”; total depth is 5”.

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 3 in.• Item Weight: 16 lbs.• Shipping Weight: 20 lbs. 24

Page 25: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Dual Cable Egress Firestop Kit (1” trade size conduit connector and firestop grommet)(2) Keys for lock(4) Hanger wiresInstallation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2405&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1047-LPDOME-T_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1047-XX_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

25

Page 26: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1052-004.5" Deep Suspended Ceiling Enclosure to 7 antennas

Category: Suspended Ceiling Enclosures with Doors

This locking 2' x 2' suspended ceiling tile enclosure is designed for APs and DASremote units with detachable antennas. This white powder-coated steelenclosure replaces a standard ceiling tile and is UL listed for installation in theplenum space. Interchangeable doors mount leading vendors APs and antennasnearly flush to the ceiling to provide for a professional, aesthetic installation.The interchangeable doors simplify AP moves, adds, and changes without liftingceiling tiles.

Features & Benefits

Locking ceiling tile enclosure designed specifically to secure wireless access points from most vendorsUL ListedMeet NEC300-22 and 300-23 for plenum installations; approved for AC line powerFully-hinged locking door, keyed alikeInterchangeable doors permit simple migration to new access points and antennasBack-box is deep enough to contain most vendors access points and connectorsEnclosure back-box is effective dust barrier to simplify ICRA compliance in hospitalsOSHPD approved

Technical SpecificationsDesign: Ceiling tile enclosure designed for access points and DAS remotes with connectors and detachable antennas. This is asteel enclosure so antennas MUST be mounted externally or on the door. Mount up to (7) external antennas on the door using thebulkhead connector kit for dipole antennas (Oberon P/N 35-BULKHD-KIT) or Oberon 34-ZDUAL or 34-DMDUAL antennas.Performance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved OPM-0110-13.De-rate AP operating temperature range by 6°C when mounted in enclosure.Locking, fully-hinged interchangeable doors for different access pointsFirestop grommet for insertion into back-box, large enough for 2 Cat6A cables1” trade size knockouts in four wallsBack-box: Effective as a dust barrier for ICRA procedure complianceConstruction: Construction: 16 ga. galvanized steel back-box; 14 ga. door, textured white powder-coated steelEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsAP max. operating temperature should be de-rated by 8° C inside the enclosureSize: 23.75 inches by 23.75 inches by 4.5 inches (603 mm by 603 mm by 76mm); back-box is 12.5 inches by 12.5 inches by 4.5inches deep (318 mm by 318 mm by 114 mm deep)

26

Page 27: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 4.5 in.• Item Weight: 16 lbs.• Shipping Weight: 17lbs.

IncludesAP mounting screws(4) Suspension wires(1) Firestop GrommetGrounding screwUniversal T-bar internal AP mounting bracketMounting instructions

Available Accessories34-DMDUAL - Dual Band WiFi Antenna: NEMA4 Enclosures34-ZDUAL - Dual Band WiFi Antennas: Oberon Enclosures, RPTNC39-BULKHD-KIT-RPTNC(F) - Pigtail Cable for Antennas on Enclosure Door - RPTNC39-BULKHD-KIT-RPSMA - Pigtail Cable for Antennas on Enclosure Door - RPSM

Videos - https://www.youtube.com/user/oberonincWatch the model 1052-00 adapter door information video View at https://www.youtube.com/watch?v=joaCdqI3YXg

Watch the Model 1052-00 product information video View at https://www.youtube.com/watch?v=joaCdqI3YXg

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1829&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1052-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1052-00_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

27

Page 28: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1052-CCOANT4.5" Deep Suspended Ceiling Enclosure - Cisco antenna

Category: Suspended Ceiling Enclosures with Doors

Features & Benefits

Locking ceiling tile enclosure designed specifically to secure wireless access points from most vendorsUL ListedMeet NEC300-22 and 300-23 for plenum installations; approved for AC line powerFully-hinged locking door, keyed alikeInterchangeable doors permit simple migration to new access points and antennasBack-box is deep enough to contain most vendors access points and connectorsEnclosure back-box is effective dust barrier to simplify ICRA compliance in hospitalsOSHPD approved

Technical SpecificationsDesign: Ceiling tile enclosure designed for access points and DAS remotes with connectors and detachable antennas. This is asteel enclosure so antennas MUST be mounted externally or on the door. Mount up to (7) external antennas on the door using thebulkhead connector kit for dipole antennas (Oberon P/N 35-BULKHD-KIT) or Oberon 34-ZDUAL or 34-DMDUAL antennas.Performance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved OPM-0110-13.De-rate AP operating temperature range by 6°C when mounted in enclosure. Locking, fully-hinged interchangeable doors for different access pointsFirestop grommet for insertion into back-box, large enough for 2 Cat6A cables1” trade size knockouts in four wallsBack-box: Effective as a dust barrier for ICRA procedure complianceConstruction: Construction: 16 ga. galvanized steel back-box; 14 ga. door, textured white powder-coated steelEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsAP max. operating temperature should be de-rated by 8° C inside the enclosureSize: 23.75 inches by 23.75 inches by 4.5 inches (603 mm by 603 mm by 76mm); back-box is 12.5 inches by 12.5 inches by 4.5inches deep (318 mm by 318 mm by 114 mm deep)

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13 28

Page 29: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 4.5 in.• Item Weight: 16 lbs.• Shipping Weight: 17 lbs.

IncludesAP mounting screws(4) Suspension wires(1) Firestop GrommetGrounding screwUniversal T-bar internal AP mounting bracketMounting instructions

Available Accessories34-DMDUAL - Dual Band WiFi Antenna: NEMA4 Enclosures34-ZDUAL - Dual Band WiFi Antennas: Oberon Enclosures, RPTNC39-BULKHD-KIT-RPTNC(F) - Pigtail Cable for Antennas on Enclosure Door - RPTNC39-BULKHD-KIT-RPSMA - Pigtail Cable for Antennas on Enclosure Door - RPSM

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=3279&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1052-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1052-00_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

29

Page 30: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1052-CCOAP4.5" Deep Suspended Ceiling Enclosure - Cisco APs

Category: Suspended Ceiling Enclosures with Doors

This locking 2' x 2' suspended ceiling tile enclosure is designed for APs and DASremote units with detachable antennas. This white powder-coated steelenclosure replaces a standard ceiling tile and is UL listed for installation in theplenum space. Interchangeable doors mount leading vendors APs and antennasnearly flush to the ceiling to provide for a professional, aesthetic installation.The interchangeable doors simplify AP moves, adds, and changes without liftingceiling tiles.

Features & BenefitsLocking ceiling tile enclosure designed specifically to secure wireless access points from most vendorsUL ListedMeet NEC300-22 and 300-23 for plenum installations; approved for AC line powerFully-hinged locking door, keyed alikeInterchangeable doors permit simple migration to new access points and antennasBack-box is deep enough to contain most vendors access points and connectorsEnclosure back-box is effective dust barrier to simplify ICRA compliance in hospitalsOSHPD approved

Technical SpecificationsDesign: Ceiling tile enclosure specifically designed for Cisco series wireless access points. Door has special mounting bracket tohold the access point in the door.Performance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved OPM-0110-13.De-rate AP operating temperature range by 6°C when mounted in enclosure. Locking, fully-hinged interchangeable doors for different access pointsFirestop grommet for insertion into back-box, large enough for 2 Cat6A cables1” trade size knockouts in four wallsBack-box: Effective as a dust barrier for ICRA procedure complianceConstruction: Construction: 16 ga. galvanized steel back-box; 14 ga. door; textured, white, powder-coated steelEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsAP max. operating temperature should be de-rated by 8° C inside the enclosureSize: 23.75 inches by 23.75 inches by 4.5 inches (603 mm by 603 mm by 76mm); back-box is 12.5 inches by 12.5 inches by 4.5inches deep (318 mm by 318 mm by 114 mm deep)

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13 30

Page 31: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 4.5 in.• Item Weight: 16 lbs.• Shipping Weight: 22 lbs.

IncludesAP mounting screws(4) Suspension wires(1) Firestop GrommetGrounding screwUniversal T-bar internal AP mounting bracketMounting instructions

Available AccessoriesAccessories

38-52-MNT-KIT

Cables for Oberon Antennas & Enclosures

34-DMDUAL - Dual Band WiFi Antenna: NEMA4 Enclosures34-ZDUAL - Dual Band WiFi Antennas: Oberon Enclosures, RPTNC39-BULKHD-KIT-RPTNC(F) - Pigtail Cable for Antennas on Enclosure Door - RPTNC39-BULKHD-KIT-RPSMA - Pigtail Cable for Antennas on Enclosure Door - RPSM

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1225&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1052-CCOAP_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1052-CCOAP_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

31

Page 32: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1052-CCOAP38004.5" Deep Suspended Ceiling Enclosure - Cisco 3800 APs

Category: Suspended Ceiling Enclosures with Doors

This locking 2' x 2' suspended ceiling tile enclosure is designed for APs and DASremote units with detachable antennas. This white powder-coated steelenclosure replaces a standard ceiling tile and is UL listed for installation in theplenum space. Interchangeable doors mount leading vendors APs and antennasnearly flush to the ceiling to provide for a professional, aesthetic installation.The interchangeable doors simplify AP moves, adds, and changes without liftingceiling tiles.

Features & BenefitsLocking ceiling tile enclosure designed specifically to secure wireless access points from most vendorsUL ListedMeet NEC300-22 and 300-23 for plenum installations; approved for AC line powerFully-hinged locking door, keyed alikeInterchangeable doors permit simple migration to new access points and antennasBack-box is deep enough to contain most vendors access points and connectorsEnclosure back-box is effective dust barrier to simplify ICRA compliance in hospitalsOSHPD approved

Technical SpecificationsDesign: Ceiling tile enclosure designed for access points and DAS remotes with connectors and detachable antennas. This is asteel enclosure so antennas MUST be mounted externally or on the door. Mount up to (7) external antennas on the door using thebulkhead connector kit for dipole antennas (Oberon P/N 35-BULKHD-KIT) or Oberon 34-ZDUAL or 34-DMDUAL antennas.Performance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved OPM-0110-13.De-rate AP operating temperature range by 6°C when mounted in enclosure.Locking, fully-hinged interchangeable doors for different access pointsFirestop grommet for insertion into back-box, large enough for 2 Cat6A cables1” trade size knockouts in four wallsBack-box: Effective as a dust barrier for ICRA procedure complianceConstruction: Construction: 16 ga. galvanized steel back-box; 14 ga. door, textured white powder-coated steelEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsAP max. operating temperature should be de-rated by 8° C inside the enclosureSize: 23.75 inches by 23.75 inches by 4.5 inches (603 mm by 603 mm by 76mm); back-box is 12.5 inches by 12.5 inches by 4.5inches deep (318 mm by 318 mm by 114 mm deep)

32

Page 33: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 4.5 in.• Item Weight: 16 lbs.• Shipping Weight: 17 lbs.

IncludesAP mounting screws(4) Suspension wires(1) Firestop GrommetGrounding screwUniversal T-bar internal AP mounting bracketMounting instructions

Available Accessories34-DMDUAL - Dual Band WiFi Antenna: NEMA4 Enclosures34-ZDUAL - Dual Band WiFi Antennas: Oberon Enclosures, RPTNC39-BULKHD-KIT-RPTNC(F) - Pigtail Cable for Antennas on Enclosure Door - RPTNC39-BULKHD-KIT-RPSMA - Pigtail Cable for Antennas on Enclosure Door - RPSM

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=3285&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1052-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1052-00_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

33

Page 34: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1052-XXX-CCEA4.5" Deep Suspended Ceiling Enclosure

Category: Suspended Ceiling Enclosures with Doors

This locking 2' x 2' suspended ceiling tile enclosure is designed for APs andsmall cell units with detachable antennas. This white powder-coated steelenclosure replaces a standard ceiling tile and is UL listed for installation in theplenum space. Interchangeable doors mount leading vendors APs and antennasnearly flush to the ceiling to provide for a professional, aesthetic installation.The interchangeable doors simplify AP moves, adds, and changes without liftingceiling tiles.

The –CCEA in the model number indicates that this enclosure has been speciallysealed to comply with City of Chicago Environmental Air (CCEA) standards, forplenum installation.

Features & Benefits

Locking ceiling tile enclosure designed specifically to secure wireless AP from most vendorsUL Listed, Meets NEC300-22 and 300-23 for plenum installations; approved for AC line powerFully-hinged locking door, keyed alike. Interchangeable doors permit simple migration to new access points and antennasBack-box is deep enough to contain most vendors access points and connectorsEnclosure back-box is effective dust barrier to simplify ICRA compliance in hospitalsOSHPD approved OPM-0110-13This enclosure has been specially sealed to comply with City of Chicago Environmental Air (CCEA) standards

Technical SpecificationsDesign: Designed for installation in hard-lid ceilings (drywall, plaster, etc.). Specifically designed for Cisco 1242, 1260 and 3500e,and Aruba Networks AP124 and AP70 access points (use of Aruba 70 access point requires Aruba Networks AP-70-MNT mountingbracket, use of Aruba Networks AP124 requires AP-120-MNT). Internal universal mounting plate accommodates access pointsfrom most manufacturers. Antennas may be mounted on the door using optional bulkhead connectors (Oberon P/N 35-BULKHD-KIT) or Oberon 34-ZDUAL antennas. Enclosure shall be supported by the building ceiling structural system, not tile grid work.Performance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved, OPM-0110-13.De-rate AP operating temperature range by 6°C when mounted in enclosure.Locking, fully-hinged interchangeable doors for different access pointsConstruction: 16 ga. back-box, 14 ga. door, textured white powder-coated steel. Fully hinged locking door, keyed alike. Doors areinterchangeable.CCEA designation indicates this product complies with City of Chicago Environmental Air requirements for installation in theplenum space. Back box has been sealed with 3M Fire Barrier Silicone Sealant 2000+Size: Flange is 17.5 inches by 17.5 inches (445 mm by 445 mm), enclosure is 12.5 inches by 12.5 inches by 4.5 inches deep (318mm by 318 mm by 114 mm), 4 inches (101 mm) useful depth with universal T-bar bracket in place.

34

Page 35: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 4.5 in.• Item Weight: 16 lbs.• Shipping Weight: 17 lbs.

IncludesAP mounting screws(4) Suspension wires(1) Firestop grommetGrounding screwUniversal T-bar internal AP mounting bracketMounting instructions

Available Accessories34-DMDUAL - Dual Band WiFi Antenna: NEMA4 Enclosures34-ZDUAL - Dual Band WiFi Antennas: Oberon Enclosures, RPTNC39-BULKHD-KIT-RPTNC(F) - Pigtail Cable for Antennas on Enclosure Door - RPTNC39-BULKHD-KIT-RPSMA - Pigtail Cable for Antennas on Enclosure Door - RPSM

Videos - https://www.youtube.com/user/oberonincWatch the model 1052-00 adapter door information video View at https://www.youtube.com/watch?v=joaCdqI3YXg

Watch the Model 1052-00 product information video View at https://www.youtube.com/watch?v=joaCdqI3YXg

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=3183&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1052-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1052-00_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

35

Page 36: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1075-CCOAPSusp Ceiling AP Enclosure-Tile cutout/Cisco APS

Category: Suspended Ceiling Enclosures with Doors

Locking multimedia ceiling enclosure mounts and secures digital mediagateways, APs and other components in the ceiling. The dome is a texturedwhite ABS plastic material, virtually transparent to wireless signals. Onceinstalled, this ceiling enclosure permits controlled access to components withoutlifting ceiling tiles. Interchangeable retrofit doors permit easy vendor andtechnology migrations. Steel enclosure fits into a cutout in the ceiling tile.

Features & Benefits

Locking ceiling tile insert telecommunications enclosure designed specifically to secure wireless access points from most vendorsUL ListedMeets NEC300-22 and 300-23 for plenum installations; approved for AC line powerFully hinged locking door, keyed alikeInterchangeable doors permit simple migration to new access points and antennasShallow back-box (3”) simplifies installation in walls and ceilingsEnclosure back-box is effective dust barrier to simplify ICRA compliance in hospitalsOSHPD approved

Technical SpecificationsDesign: Suspended ceiling insert enclosure designed for wireless access points and wireless multimedia gateways. Designed forCisco access points.Performance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved OPM-0110-13.Locking, fully-hinged interchangeable doors for different access pointsInclude firestop foam kit for cable egress1" trade size knockout on two walls. Junction box knockout in back-boxBack-box: Effective as a dust barrier for ICRA procedure complianceConstruction: 16 ga. aluminum clear coat back-box, 14 ga. door; textured, white, powder-coated steel door and 18ga. flange.Back-box is effective as a dust barrier for ICRA procedure complianceEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsAP max. operating temperature should be de-rated by 10° C inside the enclosureSize: Flange is 15 inches by 15 inches (381 mm by 381 mm); enclosure back-box is 12.75 inches by 12.75 inches by 3.0 inchesdeep (324 mm by 324 mm by 77 mm deep)

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

36

Page 37: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 15 in.• Width: 15 in.• Depth: 3 in.• Item Weight: 12 lbs.• Shipping Weight: 13 lbs.

Includes(1) Unit per Carton(2) Tile Bridges(1) Cable Egress Fire Stop Kit (1" trade size conduit connector, and fire block foam insert)(1) Universal T-bar Mount(1) Mounting Bracket and hardware(4) Hanger Wire(2) Key For LockInstallation InstructionsShipping weight: 13 lbs.

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1246&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1075-CCOAP_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1075-CCOAP_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

37

Page 38: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1075-CPSusp Ceiling AP Enclosure-Tile cutout/clear dome

Category: Suspended Ceiling Enclosures with Doors

Locking multimedia ceiling enclosure mounts and secures digital mediagateways, APs and other components in the ceiling. Once installed, this ceilingenclosure permits controlled access to components without lifting ceiling tiles.Interchangeable retrofit doors permit easy vendor and technology migrations.Steel enclosure fits into a cutout in the ceiling tile.

Features & Benefits

Locking ceiling tile insert telecommunications enclosure designed specifically to secure wireless access points from most vendorsUL Listed and designed to meet NEC300-22 and 300-23 for plenum installations; approved for AC line powerFully hinged locking door, keyed alikeInterchangeable doors permit simple migration to new access points and antennasShallow back-box (3”) simplifies installation in walls and ceilingsEnclosure back-box is effective dust barrier to simplify ICRA compliance in hospitalsOSHPD approved

Technical SpecificationsDesign: Suspended ceiling insert enclosure designed for wireless access points and wireless multimedia gateways. Clearpolycarbonate dome in door.Performance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved OPM-0110-13.Clear plastic dome is transparent to wireless signals.Locking, fully-hinged interchangeable doors for different access pointsInclude firestop foam kit for cable egress1" trade size knockout on two walls. Junction box knockout in back-boxBack-box: Effective as a dust barrier for ICRA procedure compliance; UL94-5VA clear polycarbonate dome in doorConstruction: 16 ga. aluminum clear coat back-box; 14 ga. door; textured, white, powder-coated steel door and 18ga. Flange;back-box is effective as a dust barrier for ICRA procedure compliance; UL 94-5VA clear polycarbonate dome in doorEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsAP max. operating temperature should be de-rated by 10° C inside the enclosureSize: Flange is 15 inches by 15 inches (381 mm by 381 mm), enclosure back-box is 12.75 inches by 12.75 inches by 3.0 inchesdeep (324 mm by 324 mm by 77 mm deep)

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

38

Page 39: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 15 in.• Width: 15 in.• Depth: 3 in.• Item Weight: 12 lbs.• Shipping Weight: 13 lbs.

Includes(1) Unit per carton(2) Tile Bridges(1) Cable Egress Fire Stop Kit (1" trade size conduit connector, and fire block foam insert)(1) Universal T-bar Mount(1) Mounting Bracket and hardware(4) Hanger Wire(2) Key For LockInstallation InstructionsShipping weight: 13 lbs.

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1244&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1075-CP_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1075-CP_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Application_Note_Wireless_Coverage_FAQ.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

39

Page 40: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1075-WASusp Ceiling AP Enclosure-Tile cutout/ABS dome

Category: Suspended Ceiling Enclosures with Doors

Locking multimedia ceiling enclosure mounts and secures digital mediagateways, APs and other components in the ceiling. Once installed, this ceilingenclosure permits controlled access to components without lifting ceiling tiles.Interchangeable retrofit doors permit easy vendor and technology migrations.Steel enclosure fits into a cutout in the ceiling tile.

Features & Benefits

Locking ceiling tile insert telecommunications enclosure designed specifically to secure wireless access points from most vendorsUL Listed and designed to meet NEC300-22 and 300-23 for plenum installations; approved for AC line powerFully hinged locking door, keyed alikeInterchangeable doors permit simple migration to new access points and antennasShallow back-box (3”) simplifies installation in walls and ceilingsEnclosure back-box is effective dust barrier to simplify ICRA compliance in hospitalsOSHPD approved

Technical SpecificationsDesign: Suspended ceiling insert enclosure designed for wireless access points and wireless multimedia gateways. White ABSplastic dome in door.Performance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved OPM-0110-13.ABS plastic dome is transparent to wireless signals.Locking, fully-hinged interchangeable doors for different access pointsInclude firestop foam kit for cable egress1" trade size knockout on two walls. Junction box knockout in back-boxBack-box: Effective as a dust barrier for ICRA procedure compliance; UL94-5VA white ABS plastic dome in doorConstruction: 16 ga. aluminum clear coat back-box; 14 ga. door, textured, white, powder-coated steel door and 18 ga. Flange;back-box is effective as a dust barrier for ICRA procedure compliance; UL 94-5VA white ABS plastic dome in doorEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsAP max. operating temperature should be de-rated by 10° C inside the enclosureSize: Flange is 15 inches by 15 inches (381 mm by 381 mm), enclosure back-box is 12.75 inches by 12.75 inches by 3.0 inchesdeep (324 mm by 324 mm by 77 mm deep)

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

40

Page 41: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 15 in.• Width: 15 in.• Depth: 3 in.• Item Weight: 12 lbs.• Shipping Weight: 13 lbs.

Includes(1) Unit per Carton(2) Tile Bridges(1) Cable Egress Fire Stop Kit (1" trade size conduit connector, and fire block foam insert)(1) Universal T-bar Mount(1) Mounting Bracket and hardware(4) Hanger Wire(2) Key For LockInstallation InstructionsShipping weight: 13 lbs.

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1245&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1075-WA_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1075-WA_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Application_Note_Wireless_Coverage_FAQ.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

41

Page 42: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1077-CCOAP3" deep Susp Ceiling Zone Enclosure-Cisco AP

Category: Suspended Ceiling Enclosures with Doors

Locking, 2' x 2' suspended ceiling tile enclosure mounts and secures wirelessaccess points flush to the ceiling. The interchangeable door simplifies accesspoint and antenna moves, adds, and changes without lifting ceiling tiles. Accesspoints can be mounted in the door or inside the enclosure with the configurationswith the ABS dome. “-T” version matches tegular ceiling tiles used in recessedgrids. Specify –T version for professional, aesthetic installation in recessed gridceilings.

Features & Benefits

2’ x 2’ locking ceiling tile enclosure secures wireless access points from most vendorsAttractive, textured, powder-coat finish matches many ceilingsInterchangeable doors permit simple migration to new access points and antennasShallow (3”), lightweight, aluminum back-box simplifies installation in ceilings with little space above ceiling tilesEnclosure back-box is effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: Lightweight ceiling tile enclosure designed for wireless access points with integrated antennas. Interchangeable door. Fitsinto standard 2’ x 2’ (U.S.) ceiling grid. Designed for Cisco APs.Performance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved OPM-0110-13.Locking, fully-hinged interchangeable doors for different access pointsInclude firestop foam kit for cable egress1" trade size knockout on two walls. Junction box knockout in back-boxBack-box: Effective as a dust barrier for ICRA procedure complianceConstruction: 16 ga. aluminum clear coat back-box; 14 ga. door; textured, white, powder-coated steel door and flange; back-boxis effective as a dust barrier for ICRA procedure complianceEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsAP max. operating temperature should be de-rated by 10° C inside the enclosureSize: Flange is 23.75 inches by 23.75 inches (603 mm by 603 mm), enclosure back-box is 12.75 inches by 12.75 inches by 3.0inches deep (324 mm by 324 mm by 77 mm deep)

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

42

Page 43: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 3 in.• Item Weight: 11 lbs.• Shipping Weight: 15.5 lbs.

Includes(1) Unit(1) T-bar bracket(1) Mounting bracket(1) 1" Trade size conduit connectors(1) Fire Block Foam(2) #8 – 32 wing nut(4) Lock washer(4) Support wire(2) Keys for access door lockInstallation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1249&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1077-CCOAP_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1077-CCOAP_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

43

Page 44: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1077-CCOAP3800Susp Ceiling AP Mount; Door: Cisco 3800s

Category: Suspended Ceiling Enclosures with Doors

Locking, 2' x 2' suspended ceiling tile enclosure mounts and secures wirelessaccess points flush to the ceiling. The interchangeable door simplifies accesspoint and antenna moves, adds, and changes without lifting ceiling tiles. Accesspoints can be mounted in the door or inside the enclosure with the configurationswith the ABS dome. “-T” version matches tegular ceiling tiles used in recessedgrids. Specify –T version for professional, aesthetic installation in recessed gridceilings.

Features & Benefits

2’ x 2’ locking ceiling tile enclosure secures wireless access points from most vendorsAttractive, textured, powder-coat finish matches many ceilingsInterchangeable doors permit simple migration to new access points and antennasShallow (3”), lightweight, aluminum back-box simplifies installation in ceilings with little space above ceiling tilesEnclosure back-box is effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: Economical ceiling tile enclosure designed for wireless access points with integrated antennas. Access point mounts ininterchangeable door. Fits into standard 2’ x 2’ (U.S.) ceiling grid. Door designed for Cisco 3800 series APs.Performance: UL Listed for low-voltage applications, and designed to meet NEC300-22 and 300-23 for plenum installations.OSHPD approved, OPM-0110-13. De-rate AP operating temperature range by 10°C when mounted in enclosure.Locking, quick release interchangeable door for migration to other access pointsFirestop grommet for insertion into back-box, large enough for 2 Cat6A cables1" trade size knockouts in four wallsConstruction: 20 ga. galvanized steel back-box; 18 ga. white, powder-coated steel flange and door; solid back-box fills openingbehind access point, creating an effective fire, smoke, and dust barrier to simplify ICRA complianceEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsSize: 23.75 inches by 23.75 inches by 3 inches (603 mm by 603 mm by 76mm); back-box is 12.5 inches by 12.5 inches x 3 inches

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

Measurements (Maximum values):

• Height: 12.5 in.• Width: 12.5 in.• Depth: 3 in.• Item Weight: 13 lbs.• Shipping Weight: 17 lbs. 44

Page 45: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(1) T-bar bracket(1) Mounting bracket(1) 1" Trade size conduit connectors(1) Fire Block Foam(2) #8 – 32 wing nut(4) Lock washer(4) Support wire(2) Keys for access door lockInstallation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=3115&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1077-CCOAP3800_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1077-CCOAP3800_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

45

Page 46: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1077-CCOAP3800-TSusp Ceiling AP Mount; Door: Cisco 3800s

Category: Suspended Ceiling Enclosures with Doors

Locking, 2' x 2' suspended ceiling tile enclosure mounts and secures wirelessaccess points flush to the ceiling. The interchangeable door simplifies accesspoint and antenna moves, adds, and changes without lifting ceiling tiles. Accesspoints can be mounted in the door or inside the enclosure with the configurationswith the ABS dome. “-T” version matches tegular ceiling tiles used in recessedgrids. Specify –T version for professional, aesthetic installation in recessed gridceilings.

Features & Benefits

2’ x 2’ locking ceiling tile enclosure secures wireless access points from most vendorsAttractive, textured, powder-coat finish matches many ceilingsInterchangeable doors permit simple migration to new access points and antennasShallow (3”), lightweight, aluminum back-box simplifies installation in ceilings with little space above ceiling tilesEnclosure back-box is effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: Economical ceiling tile enclosure designed for wireless access points with integrated antennas. Access point mounts ininterchangeable door. Fits into standard 2’ x 2’ (U.S.) ceiling grid. Door designed for Cisco 3800 series APs.Performance: UL Listed for low-voltage applications, and designed to meet NEC300-22 and 300-23 for plenum installations.OSHPD approved, OPM-0110-13. De-rate AP operating temperature range by 10°C when mounted in enclosure.Locking, quick release interchangeable door for migration to other access pointsFirestop grommet for insertion into back-box, large enough for 2 Cat6A cables1" trade size knockouts in four wallsConstruction: 20 ga. galvanized steel back-box; 18 ga. white, powder-coated steel flange and door; solid back-box fills openingbehind access point, creating an effective fire, smoke, and dust barrier to simplify ICRA complianceEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsSize: 23.75 inches by 23.75 inches by 3 inches (603 mm by 603 mm by 76mm); back-box is 12.5 inches by 12.5 inches x 3 inches

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

Measurements (Maximum values):

• Height: 12.5 in.• Width: 12.5 in.• Depth: 3 in.• Item Weight: 13 lbs.• Shipping Weight: 17 lbs. 46

Page 47: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(1) T-bar bracket(1) Mounting bracket(1) 1" Trade size conduit connectors(1) Fire Block Foam(2) #8 – 32 wing nut(4) Lock washer(4) Support wire(2) Keys for access door lockInstallation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=3121&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1077-CCOAP3800-T_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1077-CCOAP3800-T_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

47

Page 48: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1077-CCOAP-T3" deep Susp Ceiling Zone Enclosure-Cisco AP

Category: Suspended Ceiling Enclosures with Doors

Locking 2' x 2' suspended ceiling enclosure secures APs with integratedantennas. Replaces a standard ceiling tile and is UL listed for installation in theplenum space. Interchangeable doors mount leading vendors’ APs nearly flushto the ceiling for a professional, aesthetic installation. Interchangeable doorssimplify moves, adds, and changes without lifting ceiling tiles. The -T features aflange beveled at the edge to mimic a tegular ceiling tile used in recessed gridsuspended ceilings.

Features & Benefits

2’ x 2’ locking ceiling tile enclosure secures wireless access points from most vendorsAttractive, textured, powder-coat finish matches many ceilingsInterchangeable doors permit simple migration to new access points and antennasShallow (3”), lightweight, aluminum back-box simplifies installation in ceilings with little space above ceiling tilesEnclosure back-box is effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: Lightweight ceiling tile enclosure designed for wireless access points with integrated antennas. Interchangeable door. Fitsinto standard 2’ x 2’ (U.S.) ceiling grid. Designed for Cisco APs.Performance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved OPM-0110-13.Locking, fully-hinged interchangeable doors for different access pointsInclude firestop foam kit for cable egress1" trade size knockout on two walls. Junction box knockout in back-boxBack-box: Effective as a dust barrier for ICRA procedure complianceConstruction: 16 ga. aluminum clear coat back-box; 14 ga. door; textured, white, powder-coated steel door and flange; back-boxis effective as a dust barrier for ICRA procedure complianceEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsAP max. operating temperature should be de-rated by 10° C inside the enclosureSize: Flange is 23.75 inches by 23.75 inches (603 mm by 603 mm), enclosure back-box is 12.75 inches by 12.75 inches by 3.0inches deep (324 mm by 324 mm by 77 mm deep)

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

48

Page 49: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 3 in.• Item Weight: 11 lbs.• Shipping Weight: 15.5 lbs.

Includes(1) Unit(1) T-bar bracket(1) Mounting bracket(1) 1" Trade size conduit connectors(1) Fire Block Foam(2) #8 – 32 wing nut(4) Lock washer(4) Support wire(2) Keys for access door lockInstallation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2435&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1077-CCOAP_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1077-CCOAP_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

49

Page 50: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1077-CP3" deep Susp Ceiling Zone Enclosure-Clear dome

Category: Suspended Ceiling Enclosures with Doors

Locking, 2' x 2' suspended ceiling tile enclosure mounts and secures wirelessaccess points flush to the ceiling. The interchangeable door simplifies accesspoint and antenna moves, adds, and changes without lifting ceiling tiles. Accesspoints can be mounted in the door or inside the enclosure with the configurationswith the ABS dome. “-T” version matches tegular ceiling tiles used in recessedgrids. Specify –T version for professional, aesthetic installation in recessed gridceilings.

Features & Benefits

2’ x 2’ locking ceiling tile enclosure secures wireless access points from most vendorsAttractive, textured, powder-coat finish matches many ceilingsInterchangeable doors permit simple migration to new access points and antennasShallow (3”), lightweight, aluminum back-box simplifies installation in ceilings with little space above ceiling tilesEnclosure back-box is effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: Lightweight ceiling tile enclosure designed for wireless access points with integrated antennas. Interchangeable door. Fitsinto standard 2’ x 2’ (U.S.) ceiling grid. Clear polycarbonate dome in door.Performance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved OPM-0110-13.Clear plastic dome is transparent to wireless signals.Locking, fully-hinged interchangeable doors for different access pointsInclude firestop foam kit for cable egress1" trade size knockout on two walls; junction box knockout in back-boxBack-box: Effective as a dust barrier for ICRA procedure compliance; UL94-5VA Polycarbonate dome in doorConstruction: 16 ga. aluminum clear coat back-box; 14 ga. door; textured, white, powder-coated steel door and flange; back-boxis effective as a dust barrier for ICRA procedure compliance; UL 94-5VA clear polycarbonate dome in doorEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsAP max. operating temperature should be de-rated by 10° C inside the enclosureSize: Flange is 23.75 inches by 23.75 inches (603 mm by 603 mm); enclosure back-box is 12.75 inches by 12.75 inches by 3.0inches deep (324 mm by 324 mm by 77 mm deep)

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

50

Page 51: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 3 in.• Item Weight: 11 lbs.• Shipping Weight: 15.5 lbs.

Includes(1) Unit(1) T-bar bracket(1) Mounting bracket(1) 1" Trade size conduit connectors(1) Fire Block Foam(2) #8 – 32 wing nut(4) Lock washer(4) Support wire(2) Keys for access door lockInstallation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1247&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1077-CP_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1077-CP_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

51

Page 52: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1077-CP-T3" deep Susp Ceiling Zone Enclosure-Clear dome

Category: Suspended Ceiling Enclosures with Doors

Locking 2' x 2' suspended ceiling enclosure secures APs with integratedantennas. Replaces a standard ceiling tile and is UL listed for installation in theplenum space. Interchangeable doors mount leading vendors’ APs nearly flushto the ceiling for a professional, aesthetic installation. Interchangeable doorssimplify moves, adds, and changes without lifting ceiling tiles. The -T features aflange beveled at the edge to mimic a tegular ceiling tile used in recessed gridsuspended ceilings.

Features & Benefits

2’ x 2’ locking ceiling tile enclosure secures wireless access points from most vendorsAttractive, textured, powder-coat finish matches many ceilingsInterchangeable doors permit simple migration to new access points and antennasShallow (3”), lightweight, aluminum back-box simplifies installation in ceilings with little space above ceiling tilesEnclosure back-box is effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: Lightweight ceiling tile enclosure designed for wireless access points with integrated antennas. Interchangeable door. Fitsinto standard 2’ x 2’ (U.S.) ceiling grid. Clear polycarbonate dome in door.Performance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved OPM-0110-13.Clear plastic dome is transparent to wireless signals.Locking, fully-hinged interchangeable doors for different access pointsInclude firestop foam kit for cable egress1" trade size knockout on two walls; junction box knockout in back-boxBack-box: Effective as a dust barrier for ICRA procedure compliance; UL94-5VA Polycarbonate dome in doorConstruction: 16 ga. aluminum clear coat back-box; 14 ga. door; textured, white, powder-coated steel door and flange; back-boxis effective as a dust barrier for ICRA procedure compliance; UL 94-5VA clear polycarbonate dome in doorEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsAP max. operating temperature should be de-rated by 10° C inside the enclosureSize: Flange is 23.75 inches by 23.75 inches (603 mm by 603 mm); enclosure back-box is 12.75 inches by 12.75 inches by 3.0inches deep (324 mm by 324 mm by 77 mm deep)

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

52

Page 53: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(1) T-bar bracket(1) Mounting bracket(1) 1" Trade size conduit connectors(1) Fire Block Foam(2) #8 – 32 wing nut(4) Lock washer(4) Support wire(2) Keys for access door lockInstallation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2441&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1077-CP_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1077-CP_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Application_Note_Wireless_Coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

53

Page 54: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1077-WA3" deep Susp Ceiling Zone Enclosure-ABS dome

Category: Suspended Ceiling Enclosures with Doors

Locking, 2' x 2' suspended ceiling tile enclosure mounts and secures wirelessaccess points flush to the ceiling. The interchangeable door simplifies accesspoint and antenna moves, adds, and changes without lifting ceiling tiles. Accesspoints can be mounted in the door or inside the enclosure with the configurationswith the ABS dome. “-T” version matches tegular ceiling tiles used in recessedgrids. Specify –T version for professional, aesthetic installation in recessed gridceilings.

Features & Benefits

2’ x 2’ locking ceiling tile enclosure secures wireless access points from most vendorsAttractive, textured, powder-coat finish matches many ceilingsInterchangeable doors permit simple migration to new access points and antennasShallow (3”), lightweight, aluminum back-box simplifies installation in ceilings with little space above ceiling tilesEnclosure back-box is effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: Lightweight ceiling tile enclosure designed for wireless access points with integrated antennas. Interchangeable door. Fitsinto standard 2’ x 2’ (U.S.) ceiling grid. White ABS plastic dome in door.Performance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved OPM-0110-13.ABS plastic dome is transparent to wireless signals.Locking, fully-hinged interchangeable doors for different access pointsInclude firestop foam kit for cable egress1" trade size knockout on two walls. Junction box knockout in back-boxBack-box: Effective as a dust barrier for ICRA procedure compliance; UL94-5VA white ABS dome in doorConstruction: 16 ga. aluminum clear coat back-box; 14 ga. door; textured, white, powder-coated steel door and flange; back-boxis effective as a dust barrier for ICRA procedure compliance; UL 94-5VA white ABS plastic dome in doorEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsAP max. operating temperature should be de-rated by 10° C inside the enclosureSize: Flange is 23.75 inches by 23.75 inches (603 mm by 603 mm); enclosure back-box is 12.75 inches by 12.75 inches by 3.0inches deep (324 mm by 324 mm by 77 mm deep)

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

54

Page 55: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 3 in.• Item Weight: 11 lbs.• Shipping Weight: 15.5 lbs.

Includes(1) Unit(1) T-bar bracket(1) Mounting bracket(1) 1" Trade size conduit connectors(1) Fire Block Foam(2) #8 – 32 wing nut(4) Lock washer(4) Support wire(2) Keys for access door lockInstallation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1248&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1077-WA_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1077-WA_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Application_Note_Wireless_Coverage_FAQ.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

55

Page 56: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1077-WA-T3" deep Susp Ceiling Zone Enclosure-ABS dome

Category: Suspended Ceiling Enclosures with Doors

Locking 2' x 2' suspended ceiling enclosure secures APs with integratedantennas. Replaces a standard ceiling tile and is UL listed for installation in theplenum space. Interchangeable doors mount leading vendors’ APs nearly flushto the ceiling for a professional, aesthetic installation. Interchangeable doorssimplify moves, adds, and changes without lifting ceiling tiles. The -T features aflange beveled at the edge to mimic a tegular ceiling tile used in recessed gridsuspended ceilings.

Features & Benefits

2’ x 2’ locking ceiling tile enclosure secures wireless access points from most vendorsAttractive, textured, powder-coat finish matches many ceilingsInterchangeable doors permit simple migration to new access points and antennasShallow (3”), lightweight, aluminum back-box simplifies installation in ceilings with little space above ceiling tilesEnclosure back-box is effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: Lightweight ceiling tile enclosure designed for wireless access points with integrated antennas. Interchangeable door. Fitsinto standard 2’ x 2’ (U.S.) ceiling grid. White ABS plastic dome in door.Performance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved OPM-0110-13.ABS plastic dome is transparent to wireless signals.Locking, fully-hinged interchangeable doors for different access pointsInclude firestop foam kit for cable egress1" trade size knockout on two walls. Junction box knockout in back-boxBack-box: Effective as a dust barrier for ICRA procedure compliance; UL94-5VA white ABS dome in doorConstruction: 16 ga. aluminum clear coat back-box; 14 ga. door; textured, white, powder-coated steel door and flange; back-boxis effective as a dust barrier for ICRA procedure compliance; UL 94-5VA white ABS plastic dome in doorEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.For recessed grid ceilings, designate “–T” for tegular flange unitsAP max. operating temperature should be de-rated by 10° C inside the enclosureSize: Flange is 23.75 inches by 23.75 inches (603 mm by 603 mm); enclosure back-box is 12.75 inches by 12.75 inches by 3.0inches deep (324 mm by 324 mm by 77 mm deep)

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

56

Page 57: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 3 in.• Item Weight: 11 lbs.• Shipping Weight: 15.5 lbs.

Includes(1) Unit(1) T-bar bracket(1) Mounting bracket(1) 1" Trade size conduit connectors(1) Fire Block Foam(2) #8 – 32 wing nut(4) Lock washer(4) Support wire(2) Keys for access door lockInstallation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2411&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1077-WA_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1077-WA_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Application_Note_Wireless_Coverage_FAQ.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

57

Page 58: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1040-CCOAPCloud or Canopy Ceiling AP Installation Kit-Cisco

Category: Suspended Ceiling Mounts

Model 1040-CCOAP is an economical, easy-to-install cloud, canopy, or suspendedceiling mounting kit for APs from most vendors. A cutout is made in the ceilingpanel, the panel bridge is placed above the ceiling panel, and the AP is attachedto the white trim. The AP/trim assembly then is drawn into the panel bridge witha torsion spring, much like certain recessed lighting fixtures. The AP is recessedinto the ceiling, with only the front face exposed for optimal wireless coverage.The installation is fast, easy, professional and aesthetic. The AP trim can beeasily swapped out for alternate AP brands without tools.Patent pending

Features & Benefits

Conveniently and quickly install APs in cloud or canopy ceiling panelsAP mounts flush to the ceiling, providing an aesthetic, professionally installed appearance20 ga. galvanized steel panel bridge and adjustable hanger wire prevent ceiling panel sag or cracking

Technical SpecificationsDesign: Recessed installation kit for installing APs in cloud, canopy, or suspended ceiling panels. Comprised of steel ceiling panelbridge, adjustable hanger wire, AP bracket, and trim for Cisco APsPerformance: UL Listed for low-voltage applications and designed to meet NEC300-22 and 300-23 for plenum installationsAP trim is interchangeable for other APsConstruction: 20 ga. galvanized steel panel bridge; white, powder-coated steel trimUse hanger wire to attach to building structureSize: 16 inches by 23.75 inches by 3 inches (406 mm by 603 mm by 76mm)

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General Requirements

Measurements (Maximum values):

• Height: 18 in.• Width: 23.75 in.• Depth: 3 in.• Item Weight: 4 lbs.• Shipping Weight: 5 lbs.

Includes(1) 18" x 23.75" galvanized steel ceiling panel bridge(1) AP-specific, white powder-coated trim (see Configurations)(1) T-bar bracketAdjustable hanger wireInstallation instructions

58

Page 59: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2157&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1040-CCOAP-S_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1040_XX_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

59

Page 60: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1040-CCOAP3800Cloud or Canopy Ceiling AP Installation Kit-Cisco

Category: Suspended Ceiling Mounts

Model 1040-CCOAP3800 is an economical, easy-to-install cloud, canopy, orsuspended ceiling mounting kit for APs from most vendors. A cutout is made inthe ceiling panel, the panel bridge is placed above the ceiling panel, and the APis attached to the white trim. The AP/trim assembly then is drawn into the panelbridge with a torsion spring, much like certain recessed lighting fixtures. The APis recessed into the ceiling, with only the front face exposed for optimal wirelesscoverage. The installation is fast, easy, professional and aesthetic. The AP trimcan be easily swapped out for alternate AP brands without tools.Patent pending

Features & Benefits

Conveniently and quickly install APs in cloud or canopy ceiling panelsAP mounts flush to the ceiling, providing an aesthetic, professionally installed appearance20 ga. galvanized steel panel bridge and adjustable hanger wire prevent ceiling panel sag or cracking

Technical SpecificationsDesign: Recessed installation kit for installing APs in cloud, canopy, or suspended ceiling panels. Comprised of steel ceiling panelbridge, adjustable hanger wire, AP bracket, and trim for Cisco 3800 APsPerformance: UL Listed for low-voltage applications and designed to meet NEC300-22 and 300-23 for plenum installationsAP trim is interchangeable for other APsConstruction: 20 ga. galvanized steel panel bridge; white, powder-coated steel trimUse hanger wire to attach to building structureSize: 16 inches by 23.75 inches by 3 inches (406 mm by 603 mm by 76mm)

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General Requirements

Measurements (Maximum values):

• Height: 18 in.• Width: 23.75 in.• Depth: 3 in.• Item Weight: 4 lbs.• Shipping Weight: 5 lbs.

Includes(1) 18” x 23.75” galvanized steel ceiling panel bridge(1) AP-specific, white powder-coated trim (see Configurations)(1) T-bar bracketAdjustable hanger wireInstallation instructions

60

Page 61: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2913&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1040-CCOAP3800-S_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1040_XX_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

61

Page 62: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1044-CCOAP-BAP Mount Tile Bridge w/Back-Box - Cisco APs

Category: Suspended Ceiling Mounts

Model 1044-CCOAP is an economical, aesthetic, and easy-to-install suspendedceiling mounting kit for APs from most vendors. The AP recesses into the ceilingtile and the trim creates a professional finished appearance. The AP is recessedin the preferred ceiling orientation much like a recessed light fixture, providingideal, unobstructed wireless coverage. AP trim can be easily swapped out fornew trim if the AP brand or model is changed in the future.Patent pending

Features & BenefitsThe ceiling is an ideal location for mounting APs, however, different ceiling tile styles and finishes present a challenge to the installerto create an aesthetic, professional installation. With Oberon’s Model 1044, a cutout is made in the ceiling tile tracing the shape of theAP. A galvanized steel back-box is placed above the ceiling tile, and a white trim is placed around the AP. The AP is attached to auniversal mounting T-bar bracket which is pressed into the back-box for a flush-to-the-ceiling look.

Conveniently and quickly install APs in suspended ceiling environmentAP mounts flush to the ceiling, providing an aesthetic, professionally installed appearanceTile bridge prevents ceiling tile sag or cracking

Technical SpecificationsDesign: Recessed installation kit for installing APs in fire rated 2’ x 2’ suspended ceiling tiles. Comprised of steel ceiling tile bridge,hanger wire, AP bracket, and trim for Cisco APs.Performance: UL Listed for low-voltage applications and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPDapproved, OPM-0110-13. De-rate AP operating temperature range by 11°C when mounted in enclosure.AP trim is interchangeable for other APsFirestop grommet for insertion into back-box, large enough for 2 Cat6A cablesConstruction: 20 ga. galvanized steel tile bridge and back-box and white, powder-coated steel trim; solid back-box fills openingbehind AP, creating an effective fire, smoke, and dust barrier to simplify ICRA complianceEnclosure must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireMaximum weight inside enclosure is 25 lbs.In healthcare environment specify “-F” for front-attach trim; the front-attach trim and AP can be detached from the mount withoutlifting ceiling tilesSize: 18 inches by 23.75 inches by 3 inches (457 mm by 603 mm by 76mm; back-box is 12.5 inches by 12.5 inches x 3 inches

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

62

Page 63: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 18 in.• Width: 23.75 in.• Depth: 3 in.• Item Weight: 8 lbs.• Shipping Weight: 9 lbs.

Includes(1) Unit(1) 12.5” x 12.5” x 3” deep galvanized back-box(1) 18” x 23.75” ceiling tile bridge(1) AP-specific, white powder-coated trim (See Configurations)(1) Universal AP mounting T-bar(1) Fire stop cable grommet, large enough for 2 category 6A cablesInstallation instructions

Videos - https://www.youtube.com/user/oberoninc1044 Installation Video View at https://youtu.be/8nmbJE4cUjA

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2163&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1044-CCOAP_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1044_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

63

Page 64: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1045-00Above-Ceiling AP Mount

Category: Suspended Ceiling Mounts

Model 1045 is a sturdy, above-ceiling hanger bar designed to support APs frommost leading vendors. When the AP must be mounted above the ceiling, theModel 1045 secures the AP in the right location just above the ceiling tile. Asupport wire is included to ensure compliance with the National Electric Code(NEC®) Section 300-11, requiring an independent support. The 1045 alsoincludes a light pipe, which can be pressed through the ceiling tile to enableobservation of the APs status LED without lifting ceiling tiles.

Features & Benefits

Sturdy, UL Listed hanger bar placed above suspended ceiling, designed for most vendors' wireless access pointsT-bar attaches to hanger bar and permits most vendors' AP to be attached using ceiling T-bar clip1.5" light pipe pushed through ceiling tile enables observation of AP status LED without lifting ceiling tileSecure AP above the ceiling

Technical SpecificationsDesign: Above-ceiling installation kit for installing wireless access points above a 2’ by 2’ suspended ceiling. Mounts most vendors'access points. Performance: UL listed and designed to meet NEC300-22 and 300-23 for plenum installations.Includes hanger bar, hanger bar extensions, adjustable wire rope hanger wire, universal T-bar, and light pipeMounting hardware for most vendors' access pointsLight pipe can be pressed through ceiling tile so that status LED is visibleMount must be supported by the building structure, independent of the suspended ceiling, per NEC paragraph 300.11Includes adjustable wire rope hanger wireMaximum weight supported is 25 lbs.Size: 1 inches by 23.75 inches by 3 inches (25 mm by 603 mm by 76mm)

Measurements (Maximum values):

• Height: 23.75 in.• Width: 1 in.• Depth: 3 in.• Item Weight: 1 lb.• Shipping Weight: 1 lb.

Includes(1) T-bar mounting bracket(1) Hanger bar(2) Hanger bar extensions(1) Wire rope clip(1) Speed Link wire rope(2) No. 10-32 x 3/8 machine screws(2) No. 10-32 hex nut(1) 1.5" light pipe 64

Page 65: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1252&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1045-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1045-00_Customer_Print_1.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

65

Page 66: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1064-00Suspended Ceiling Locking Mount-Cisco APs

Category: Suspended Ceiling Mounts

This locking, suspended ceiling tile-like mount is designed to provide aconvenient way to secure Cisco wireless access points in the ceiling. Many of the106X series AP mounts feature a unique, patented locking mechanism whichdraws the AP part way into the mount, exposing only the antenna face of the AP,for the ultimate in wireless coverage, aesthetics, and physical security.Textured, white powder-coated steel and aluminum construction.

Features & Benefits

Economical 2' x 2' suspended ceiling mount designed specifically for aesthetic, secure mounting of many popular Cisco accesspointsEnclosure back-box is effective dust barrier to simplify ICRA procedure compliancePatented locking mechanismNOT designed for Cisco 2800/3800 Series APs

Technical SpecificationsDesign: Economical ceiling mount designed specifically for aesthetic, secure mounting of the Cisco series access points.Performance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved OPM-0110-13.NOT designed for Cisco 2800/3800 series APsConstruction: 18 ga. textured white powder-coated steel flange, 16 ga. aluminum back-box; patent pending locking mechanism,keyed alike, secures AP into the ceiling mount; solid back-box fills opening behind access point, creating an effective fire, smoke,and dust barrier to simplify ICRA complianceProduct must be supported by the building structure independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireAP max. operating temperature should be de-rated by 10° C inside the enclosureSize: 23.75 inches by 23.75 inches by 2.5 inches (603 mm by 603 mm by 64 mm) inches

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 2 in.• Item Weight: 10 lbs.• Shipping Weight: 13 lbs.

66

Page 67: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Cable egress fire block kit (1" trade size conduit connector, and firestop grommet)(2) Keys for lock(4) Hanger wiresInstallation instructionsShipping Weight: 13 lbs.

Available Accessories39-STANDOFF - Standoffs for 1064

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1240&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1064-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1064-00_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

67

Page 68: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1064-TSuspended Ceiling Locking Mount-Cisco APs, tegular

Category: Suspended Ceiling Mounts

This locking, suspended ceiling tile-like mount is designed to provide aconvenient way to secure Cisco wireless access points in the ceiling. Many of the106X series AP mounts feature a unique, patented locking mechanism whichdraws the AP part way into the mount, exposing only the antenna face of the AP,for the ultimate in wireless coverage, aesthetics, and physical security.Textured, white powder-coated steel and aluminum construction.

Features & Benefits

Economical 2' x 2' suspended ceiling mount designed specifically for aesthetic, secure mounting of many popular Cisco accesspointsEnclosure back-box is effective dust barrier to simplify ICRA procedure compliancePatented locking mechanismNOT designed for Cisco 2800/3800 Series APs

Technical SpecificationsDesign: Economical ceiling mount designed specifically for aesthetic, secure mounting of the Cisco series access point.Performance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved OPM-0110-13.NOT designed for Cisco 2800/3800 series APsDesignate –T units for installation in recessed grid ceilingsConstruction: 18 ga. textured white powder-coated steel flange, 16 ga. aluminum back-box; patent pending locking mechanism,keyed alike, secures AP into the ceiling mount; solid back-box fills opening behind access point, creating an effective fire, smoke,and dust barrier to simplify ICRA complianceProduct must be supported by the building structure independent of the suspended ceiling, per NEC paragraph 300.11; includeshanger wireAP max. operating temperature should be de-rated by 10° C inside the enclosureSize: 23.75 inches by 23.75 inches by 2.5 inches (603 mm by 603 mm by 64 mm) inches

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 2 in.• Item Weight: 10 lbs.• Shipping Weight: 13 lbs.

68

Page 69: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Cable egress fire block kit (1" trade size conduit connector, and firestop grommet)(2) Keys for lock(4) Hanger wiresInstallation instructionsShipping Weight: 13 lbs.

Available Accessories39-STANDOFF - Standoffs for 1064

Videos - https://www.youtube.com/user/oberonincWatch the model 1064-T installation video View at http://oberonwireless.com/includes/1064-00.swf

Watch the model 1064-T product information video View at http://www.youtube.com/watch?v=OFsQ0wqItmk

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1241&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1064-T_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1064-T_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

69

Page 70: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1006-CCOAPRight-Angle AP Wall Bracket for Cisco APs

Category: Wall and Hard Ceiling - Surface Mount - Right-Angle Brackets

Many AP manufacturers recommend APs be mounted in a horizontal orientation.Secure APs from most manufacturers in areas where wall mounting may berequired, such as residence halls, hotels, and other hard lid venues. The AP ispartially recessed into the right-angle bracket, exposing only the antenna face ofthe AP. Conduit, raceways, and cable can be terminated in the bracket. The APcan be locked in place using the manufacturer’s locking features. Specify AP andmodel when ordering.Patent pending

Features & Benefits

Conveniently install wireless APs on walls and above ceilingsEnables wireless access points to be mounted in preferred horizontal orientationAP is partially recessed into bracket, providing aesthetic appearanceCan be mounted directly over telecommunications outlet

Technical SpecificationsDesign: Right-angle mounting bracket for securing wireless access points on walls. Designed to mount the access point in thepreferred horizontal orientation. For Cisco 2700, 3600, 3700 APs.AP is partially recessed into bracket, providing aesthetic appearanceFor Cisco APs, use AIR-AP-BRACKET-2Construction: 12 ga. white powder-coated steelSize: 11 inches by 11 inches by 2.5 inches (280mm by 280mm by 64mm)

Measurements (Maximum values):

• Height: 11 in.• Width: 11 in.• Depth: 2.5 in.• Item Weight: 4 lbs.• Shipping Weight: 6 lbs.

Includes(1) Right-Angle Bracket(1) AP mounting plate(1) Installation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2494&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1006-CCOAP_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Oberon_Model_1006-CCOAP_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf70

Page 71: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1006-CCOAP3800Right-Angle AP Wall Bracket for Cisco 2800/3800 Series APs

Category: Wall and Hard Ceiling - Surface Mount - Right-Angle Brackets

Many AP manufacturers recommend APs be mounted in a horizontal orientation.Secure APs from most manufacturers in areas where wall mounting may berequired, such as residence halls, hotels, and other hard lid venues. The AP ispartially recessed into the right-angle bracket, exposing only the antenna face ofthe AP. Conduit, raceways, and cable can be terminated in the bracket. The APcan be locked in place using the manufacturer’s locking features. Specify AP andmodel when ordering.

Features & Benefits

Conveniently install wireless APs on walls and above ceilingsEnables wireless access points to be mounted in preferred horizontal orientationAP is partially recessed into bracket, providing aesthetic appearanceCan be mounted directly over telecommunications outlet

Technical SpecificationsDesign: Right-angle mounting bracket for securing wireless access points on walls. Designed to mount the access point in thepreferred horizontal orientation. For Cisco 3800 series access points.AP is partially recessed into bracket, providing aesthetic appearanceFor Cisco APs, use AIR-AP-BRACKET-2Construction: 12 ga. white powder-coated steelSize: 11 inches by 11 inches by 2.5 inches (280mm by 280mm by 64mm)

Measurements (Maximum values):

• Height: 11 in.• Width: 11 in.• Depth: 2.5 in.• Item Weight: N/A• Shipping Weight: N/A

Includes(1) Right-Angle Bracket(1) AP mounting plate(1) Installation instructions

Videos - https://www.youtube.com/user/oberoninc1006-CCOAP3800 Installation Video View at https://www.youtube.com/watch?v=A9soNZLwZHA

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2613&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1006-CCOAP3800_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1006-CCOAP3800_Customer_Print.pdf71

Page 72: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

72

Page 73: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1006-HLARight-Angle AP Wall Bracket for Cisco AP with Hyperlocation

AntennaCategory: Wall and Hard Ceiling - Surface Mount - Right-Angle Brackets

Many AP manufacturers recommend APs be mounted in a horizontal orientation.Secure APs from most manufacturers in areas where wall mounting may berequired, such as residence halls, hotels, and other hard lid venues. The AP ispartially recessed into the right-angle bracket, exposing only the antenna face ofthe AP. Conduit, raceways, and cable can be terminated in the bracket. The APcan be locked in place using the manufacturer’s locking features. Specify AP andmodel when ordering.

Features & Benefits

Conveniently install wireless APs on walls and above ceilingsEnables wireless access points to be mounted in preferred horizontal orientationAP is partially recessed into bracket, providing aesthetic appearanceCan be mounted directly over telecommunications outlet

Technical SpecificationsDesign: Right-angle mounting bracket for securing wireless access points on walls. Designed to mount the access point in thepreferred horizontal orientation. For Cisco access point with HLA antenna.AP is partially recessed into bracket, providing aesthetic appearanceFor Cisco APs, use AIR-AP-BRACKET-2Construction: 12 ga. white powder-coated steelSize: 15 inches by 15 inches by 4 inches (381mm by 381mm by 102mm)

Measurements (Maximum values):

• Height: 15 in.• Width: 15 in.• Depth: 4 in.• Item Weight: 4 lbs.• Shipping Weight: 6 lbs.

Includes(1) Right-Angle Bracket(1) AP mounting plate(1) Installation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2601&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1006-HLA_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1006-HLA_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf73

Page 74: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1008-AP3800-COVERRight-Angle AP Joist or Wall Bracket with Black Vanity Cover for

Cisco 3800 seriesCategory: Wall and Hard Ceiling - Surface Mount - Right-Angle Brackets

Mount APs in open ceilings with this convenient beam clamp. Quickly install APin preferred horizontal orientation. Includes two beam clamps and a paintable,plastic vanity cover which is virtually transparent to wireless signal. Ideal forrestaurants and retail environments with open ceilings. Conduit, raceways, andcable can be terminated in the bracket to for a clean appearance. The AP can belocked in place using the AP manufacturer’s locking features.

Features & Benefits

Conveniently install and conceal AP in open ceiling environmentEnables APs to be mounted in preferred horizontal orientationPainting the AP may void manufacturers warranty, so Oberon includes a paintable, black plastic vanity cover (please seeCONFIGURATIONS)T-bar bracket accommodates APs from most vendors; includes features for mounting Cisco AIR-BRACKET directly to the right-angle bracketBeam mount clamps allow it to be mounted directly to a beam or truss

Technical SpecificationsDesign: Right-angle mounting bracket for securing APs on walls, and on ceiling joists and beams in open ceilings. Designed tomount the AP in the preferred horizontal orientation. Includes beam clamps and black vanity cover for AP. Designed for Cisco3800 series APs.Includes adjustable T-bar bracket for attaching most vendors’ APs, black beam clamps and hardwareConstruction: 10 ga. black powder-coated steel Includes Oberon Model 33-AP3800-COVER, attachable, paintable black UL94-5VA ABS plastic vanity cover, transparent to wirelesssignalAccommodates APs up to 9” x 9”Size: 8.5 inches by 7 inches by 3 inches (215 mm by 178 mm by 76 mm)

Standards for SafetyUL-95-5VA ABS plastic vanity cover

Measurements (Maximum values):

• Height: 8.5 in.• Width: 7.00 in.• Depth: 3.00 in.• Item Weight: 2.5 lbs.• Shipping Weight: 3 lbs.

74

Page 75: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Right-angle mount(2) Beam clamps(1) T-bar bracket(1) Wire tie(1) Vanity cover (please see CONFIGURATIONS)(2) Interlocking adhesive strips(2) #6 - 32 screw (for attaching T-bar bracket)(4) #8 - 32 screw (for attaching AP mounting plate)(1) Installation instructions

Available Accessories39-HLA-PLATE - Bracket accessory for Cisco Hyperlocation Antenna39-1008-SPKRMNT - Mounting bracket assembly for the Model 1008/1009 series

Videos - https://www.youtube.com/user/oberoninc1008 Series Installation Video View at https://youtu.be/pTQ-63wLtdY

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2621&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1008-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1008-AP3800-COVER_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

75

Page 76: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1008-AP-COVERRight-Angle AP Joist or Wall Bracket with Black Vanity Cover for

most vendors’ APsCategory: Wall and Hard Ceiling - Surface Mount - Right-Angle Brackets

Mount APs in open ceilings with this convenient beam clamp. Quickly install APin preferred horizontal orientation. Includes two beam clamps and a paintable,plastic vanity cover which is virtually transparent to wireless signal. Ideal forrestaurants and retail environments with open ceilings. Conduit, raceways, andcable can be terminated in the bracket to for a clean appearance. The AP can belocked in place using the AP manufacturer’s locking features.

Features & Benefits

Conveniently install and conceal AP in open ceiling environmentEnables APs to be mounted in preferred horizontal orientationPainting the AP may void manufacturers warranty, so Oberon includes a paintable, black plastic vanity cover (please seeCONFIGURATIONS)T-bar bracket accommodates APs from most vendors; includes features for mounting Cisco AIR-BRACKET directly to the right-angle bracketBeam mount clamps allow it to be mounted directly to a beam or truss

Technical SpecificationsDesign: Right-angle mounting bracket for securing APs on walls, and on ceiling joists and beams in open ceilings. Designed tomount the AP in the preferred horizontal orientation. Includes beam clamps and black vanity cover for AP. Accommodates mostvendors’ APs.Includes adjustable T-bar bracket for attaching most vendors’ APs, black beam clamps and hardwareConstruction: 10 ga. black powder-coated steelIncludes Oberon Model 33-AP-COVER, attachable, paintable black UL94-5VA ABS plastic vanity cover, transparent to wirelesssignalAccommodates APs up to 9" x 9"Size: 8.5 inches by 7 inches by 3 inches (215 mm by 178 mm by 76 mm)

Standards for SafetyUL-95-5VA ABS plastic vanity cover

Measurements (Maximum values):

• Height: 8.5 in.• Width: 7 in.• Depth: 3 in.• Item Weight: 2.5 lbs.• Shipping Weight: 3 lbs.

76

Page 77: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Right-angle mount(2) Beam clamps(1) T-bar bracket(1) Wire tie(1) Vanity cover (please see CONFIGURATIONS)(2) Interlocking adhesive strips(2) #6 - 32 screw (for attaching T-bar bracket)(4) #8 - 32 screw (for attaching AP mounting plate)(1) Installation instructions

Available Accessories39-HLA-PLATE - Bracket accessory for Cisco Hyperlocation Antenna39-1008-SPKRMNT - Mounting bracket assembly for the Model 1008/1009 series

Videos - https://www.youtube.com/user/oberoninc1008 Series Installation Video View at https://youtu.be/pTQ-63wLtdY

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1323&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1008-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1008-AP-COVER_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

77

Page 78: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1008-HLA-COVERRight-Angle AP Joist or Wall Bracket with Black Vanity Cover for

Cisco AP and HLA antennaCategory: Wall and Hard Ceiling - Surface Mount - Right-Angle Brackets

Mount APs in open ceilings with this convenient beam clamp. Quickly install APin preferred horizontal orientation. Includes two beam clamps and a paintable,plastic vanity cover which is virtually transparent to wireless signal. Ideal forrestaurants and retail environments with open ceilings. Conduit, raceways, andcable can be terminated in the bracket to for a clean appearance. The AP can belocked in place using the AP manufacturer’s locking features.

Features & Benefits

Conveniently install and conceal AP in open ceiling environmentEnables APs to be mounted in preferred horizontal orientationPainting the AP may void manufacturers warranty, so Oberon includes a paintable, black plastic vanity cover (please seeCONFIGURATIONS)T-bar bracket accommodates APs from most vendors; includes features for mounting Cisco AIR-BRACKET directly to the right-angle bracketBeam mount clamps allow it to be mounted directly to a beam or truss

Technical SpecificationsDesign: Right-angle mounting bracket for securing APs on walls, and on ceiling joists and beams in open ceilings. Designed tomount the AP in the preferred horizontal orientation. Includes beam clamps and black vanity cover for Cisco AP and HLA antenna.Includes adjustable T-bar bracket for attaching most vendors’ APs, black beam clamps and hardware, and Oberon 39-HLA-PLATEfor HLA antennaConstruction: 10 ga. black powder-coated steel Includes Oberon Model 33-HLA-COVER, attachable, paintable black UL94-5VA ABS plastic vanity cover, transparent to wirelesssignalSize: 8.5 inches by 7 inches by 3 inches (215 mm by 178 mm by 76 mm)

Standards for SafetyUL-95-5VA ABS plastic vanity cover

Measurements (Maximum values):

• Height: 8.5 in.• Width: 7.00 in.• Depth: 3.00 in.• Item Weight: 2.5 lbs.• Shipping Weight: 3 lbs.

78

Page 79: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Right-angle mount(2) Beam clamps(1) T-bar bracket(1) Wire tie(1) Vanity cover (please see CONFIGURATIONS)(2) Interlocking adhesive strips(2) #6 - 32 screw (for attaching T-bar bracket)(4) #8 - 32 screw (for attaching AP mounting plate)(1) Installation instructions

Available Accessories39-HLA-PLATE - Bracket accessory for Cisco Hyperlocation Antenna39-1008-SPKRMNT - Mounting bracket assembly for the Model 1008/1009 series

Videos - https://www.youtube.com/user/oberoninc1008 Series Installation Video View at https://youtu.be/pTQ-63wLtdY

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2626&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1008-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1008-HLA-COVER_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

79

Page 80: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1008-MR-COVERRight-Angle AP Joist or Wall Bracket with Black Vanity Cover for

Meraki MR32,34, 42, and other APsCategory: Wall and Hard Ceiling - Surface Mount - Right-Angle Brackets

Mount APs in open ceilings with this convenient beam clamp. Quickly install APin preferred horizontal orientation. Includes two beam clamps and a paintable,plastic vanity cover which is virtually transparent to wireless signal. Ideal forrestaurants and retail environments with open ceilings. Conduit, raceways, andcable can be terminated in the bracket to for a clean appearance. The AP can belocked in place using the AP manufacturer’s locking features.

Features & Benefits

Conveniently install and conceal AP in open ceiling environmentEnables APs to be mounted in preferred horizontal orientationPainting the AP may void manufacturers warranty, so Oberon includes a paintable, black plastic vanity cover (please seeCONFIGURATIONS)T-bar bracket accommodates APs from most vendors; includes features for mounting Cisco AIR-BRACKET directly to the right-angle bracketBeam mount clamps allow it to be mounted directly to a beam or truss

Technical SpecificationsDesign: Right-angle mounting bracket for securing APs on walls, and on ceiling joists and beams in open ceilings. Designed tomount the AP in the preferred horizontal orientation. Includes beam clamps and black vanity cover for Meraki MR32,34, 42, andother APs.Includes adjustable T-bar bracket for attaching most vendors’ APs, black beam clamps and hardwareConstruction: 10 ga. black powder-coated steel Includes Oberon Model 33-MR-COVER, attachable, paintable black UL94-5VA ABS plastic vanity cover, transparent to wirelesssignalSize: 8.5 inches by 7 inches by 3 inches (215 mm by 178 mm by 76 mm)

Standards for SafetyUL-95-5VA ABS plastic vanity cover

Measurements (Maximum values):

• Height: 8.5 in.• Width: 7.00 in.• Depth: 3.00 in.• Item Weight: 2.5 lbs.• Shipping Weight: 3 lbs.

80

Page 81: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Right-angle mount(2) Beam clamps(1) T-bar bracket(1) Wire tie(1) Vanity cover (please see CONFIGURATIONS)(2) Interlocking adhesive strips(2) #6 - 32 screw (for attaching T-bar bracket)(4) #8 - 32 screw (for attaching AP mounting plate)(1) Installation instructions

Available Accessories39-HLA-PLATE - Bracket accessory for Cisco Hyperlocation Antenna39-1008-SPKRMNT - Mounting bracket assembly for the Model 1008/1009 series

Videos - https://www.youtube.com/user/oberoninc1008-MR-COVER Installation Video View at https://youtu.be/T5pmVUcncTc

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2631&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1008-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1008-MR-COVER_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

81

Page 82: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1009-00Economy Universal Right-Angle AP Wall Bracket: White

Category: Wall and Hard Ceiling - Surface Mount - Right-Angle Brackets

Many AP manufacturers recommend that access points be mounted in ahorizontal orientation, which may be difficult when mounting on walls. Model1009 mounts and secures APs from most manufacturers in areas where wallmounting may be required, such as residence halls, hotels, and other hard lidvenues. Conduit, raceways, and cable can be terminated in the bracket toprovide for a clean appearance. The AP can be locked in place using themanufacturer’s locking features.

Features & Benefits

Conveniently install APs on walls and above ceilingsDesigned to enable wireless access points to be mounted in preferred horizontal orientationT-bar bracket accommodates access points from most vendorsCan be mounted directly over telecommunications outlet

Technical SpecificationsDesign: Right-angle mounting bracket for securing wireless access points on walls. Designed to mount the access point in thepreferred horizontal orientation. Accommodates most vendors' access points.Includes adjustable T-bar bracket for attaching most vendors’ APsConstruction: 10 ga. white powder-coated steelAccommodates wireless access points up to 9” x 9”Size: 8.5 inches by 7 inches by 3 inches (215 mm by 178 mm by 76 mm)

Measurements (Maximum values):

• Height: 8.50 in.• Width: 7.00 in.• Depth: 3.00 in.• Item Weight: 2.5 lbs.• Shipping Weight: 3 lbs.

Includes(1) Right-angle wall mount(2) #6 - 32 screw (for attaching T-bar bracket)(4) #8 - 32 screw (for attaching Cisco mounting plate)(1) T-bar bracket(1) Tie wrapInstallation Instructions

Available Accessories39-HLA-PLATE - Bracket accessory for Cisco Hyperlocation Antenna39-1008-SPKRMNT - Mounting bracket assembly for the Model 1008/1009 series

82

Page 83: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1324&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1009-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1009-00_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

83

Page 84: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1010-00Right-Angle AP Mount with Universal T-bar Bracket, No Cover

Category: Wall and Hard Ceiling - Surface Mount - Right-Angle Brackets

This right-angle mounting bracket has sidewalls to help conceal cabling and canbe placed directly over data outlet. Quickly install AP in preferred horizontalorientation. Mounting features for Cisco APs, with universal T-bar for most othervendors’ APs. White powder-coated steel. Ideal for hard lid environments such asresidence halls.

Features & Benefits

Designed for mounting most vendors' enterprise wireless access points on the wallRight-angle design mounts access point in preferred orientation

Technical SpecificationsDesign: Wedge-shaped right-angle mounting bracket for securing wireless access points on walls. Designed to mount the accesspoint in the preferred horizontal orientation. Accommodates most vendors' access points.Knockouts on two sidewalls for .75” trades size conduit connectorsIncludes adjustable T-bar bracket for attaching most vendors’ APsConstruction: 18 ga. white powder-coated steelSize: 9 inches by 7 inches by 5 inches (229 mm by 178 mm by 127 mm)

Measurements (Maximum values):

• Height: 9 in.• Width: 7 in.• Depth: 5 in.• Item Weight: 2 lbs.• Shipping Weight: 3 lbs.

Includes(1) Right-angle wall mount(1) T-bar bracket(4) #6-32 screws (for attaching T-bar)(4) #8 - 32 screw (for attaching access point mounting plate)(1) Tie wrapInstallation instructions

Available Accessories39-HLA-PLATE - Bracket Accessory for Cisco Hyperlocation Antenna

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1289&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1010-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1010-00_Customer_Print.pdf

84

Page 85: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

85

Page 86: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1011-00Right-Angle AP Mount with Universal T-bar Bracket and Cover

Category: Wall and Hard Ceiling - Surface Mount - Right-Angle Brackets

This right-angle mounting bracket has a hinged, snap-down cover and sidewallsto help conceal cabling and can be placed directly over data outlet. Quicklyinstall AP in preferred horizontal orientation. Mounting features for Cisco APswith universal T-bar for most other vendors’ APs. White powder-coated steel.Ideal for hard lid environments such as hotels and retails spaces.

Features & Benefits

Designed for mounting most vendors' enterprise APs on the wallEnables AP to be mounted in the preferred horizontal orientationCan be mounted directly over telecommunications outlet

Technical SpecificationsDesign: Wedge-shaped right-angle mounting bracket with cover for securing wireless access points on walls. Designed to mountthe access point in the preferred horizontal orientation. Accommodates most vendors' access points.Knockouts on two sidewalls for .75” trades size conduit connectorsHinged cover to conceal cablingIncludes adjustable T-bar bracket for attaching most vendors’ APsConstruction: 18 ga. white powder-coated steelSize: 9 inches by 7 inches by 5 inches (229 mm by 178 mm by 127 mm)

Measurements (Maximum values):

• Height: 9 in.• Width: 7 in.• Depth: 5 in.• Item Weight: 3 lbs.• Shipping Weight: 3.5 lbs.

Includes(1) Right-angle wall mountT-bar bracket(4) #8 - 32 screw (for attaching access point mounting plate)(2) #6 - 32 screw (for attaching T-Bar bracket)(1) Tie wrapInstallation instructions

Available Accessories39-HLA-PLATE - Bracket Accessory for Cisco Hyperlocation Antenna

Videos - https://www.youtube.com/user/oberoninc1011-00 Installation Video View at https://youtu.be/xRCPbcooWe8

86

Page 87: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1290&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1011-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1011-00_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

87

Page 88: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1012-00Right-Angle AP Mount with Universal T-bar Bracket and Locking

CoverCategory: Wall and Hard Ceiling - Surface Mount - Right-Angle Brackets

This right-angle wall mounting bracket has a receiver plate which locks the APinto place. The cover and sidewalls conceal cabling and can be placed directlyover data outlet. Quickly install and lock the AP in the preferred horizontalorientation. Receiver plate is designed for Cisco and many other vendors’ APs. 3-position lock unlocks cover first, then AP receiver plate. Ideal for hard lidenvironments such as classrooms and residence halls for extra security.

Features & Benefits

Right-angle design mounts access point in preferred orientationSecure access points with patented locking mechanismCan be mounted directly over telecommunications outlet

Technical SpecificationsDesign: Locking, wedge-shaped right-angle mounting bracket with cover for securing wireless access points on walls. Designed tomount the access point in the preferred horizontal orientation. Designed for Cisco and Aruba access points.Knockouts on two sidewalls for .75” trades size conduit connectorsLocking, hinged cover to conceal cabling, keyed alikeIncludes receiver plate for different vendors’ APsConstruction: 18 ga. white powder-coated steelSize: 9 inches by 7 inches by 5 inches (229 mm by 178 mm by 127 mm)

Measurements (Maximum values):

• Height: 9 in.• Width: 7 in.• Depth: 5 in.• Item Weight: 2 lbs.• Shipping Weight: 3.5 lbs.

Includes(1) Unit(1) Receiver plate for APInstallation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1302&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1012-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1012-00_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf 88

Page 89: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 900-00Surface Wall Mount Box for Wireless Access Points

Category: Wall and Hard Ceiling - Surface Mount - Surface Mount - Enclosures

High-density WiFi installations require a large number of APs to be mountedthroughout the facility. The Model 900 mounts and secures APs from manyvendors directly on the wall, with a convenient location to terminate the cable.The 900 can be mounted directly over a wall outlet or anywhere on the wall orceiling. The 900 back plate is fastened to the wall, the AP is fastened to the 900front plate, cabling is terminated inside, and the two halves are fastenedtogether to form a box.

Features & Benefits

Surface mount wireless access points from Cisco, Aruba Networks, and other vendorsProvides for location to terminate local patch cord inside boxMount directly over wall outlet or anywhere on ceiling or wall with cable fed through conduit or raceway

Technical SpecificationsLow-profile, 2-part constructionknockout on sidewall for cable egressConstruction: 20 ga. white powder-coated steelSize: 6.26 inches by 6.20 inches by 2.02 inches (159.004mm by 157.48mm by 51.308mm)

Measurements (Maximum values):

• Height: 6.31 in.• Width: 6.20 in.• Depth: 2.05 in.• Item Weight: 1.5 lbs.• Shipping Weight: 2 lbs.

Includes(1) Steel wall mount boxAssembly hardware(1) Installation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2343&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model900-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model900-00_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

89

Page 90: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 900-HCHanging Conduit or Pendant Mount Box for APs

Category: Wall and Hard Ceiling - Surface Mount - Surface Mount - Enclosures

Hanging conduit or pendant mount box for wireless access points. Designed tomount Cisco AP directly to conduit hanging from ceiling. Facilitates standardscompliant termination of horizontal cable inside box, and connecting shortequipment cord to AP.

Technical Specifications

Design: Hanging conduit or pendant mount box for wireless access points. Designed to mount Cisco AP directly to conduit hangingfrom ceiling. Facilitates standards compliant termination of horizontal cable inside box, and connecting short equipment cord toAP.Low-profile, hinged box. Base fastens to conduit, AP fastens to cover.Knockouts on 2 sidewalls for cable egressConstruction: 20 ga. white powder-coated steelSize: 6.26 inches by 6.20 inches by 2.02 inches (159.004mm by 157.48mm by 51.308mm)

Measurements (Maximum values):

• Height: 6.26 in.• Width: 6.20 in.• Depth: 2.02 in.• Item Weight: N/A• Shipping Weight: N/A

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2982&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model900-HC_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model900-HC_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

90

Page 91: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1013-002-Axis Articulating AP/Antenna Mount

Category: Wall and Hard Ceiling - Surface Mount - Surface Mount - Enclosures

2-axis Articulating wall mount for most manufacturers’ APs and directive (orpatch) antennas on pillars and walls. AP and directional antenna attach to thismount, and the antenna can be pointed in any direction to achieve desiredwireless coverage. Wall mount bracket can be placed directly over data outlet.Designed for Cisco and Aruba Networks APS and directive antenna, and manyother vendors’ APs. Ideal for classrooms, auditoriums, and stadiums wheredirectional coverage is required.

Features & Benefits

Swivels on two axes to provide down-tilt and azimuth coverage desiredDesigned for mounting most vendors enterprise wireless access points with external antennas on the wall or ceilingDesigned for high-density WiFi installationsCan be mounted over telecommunications outlet

Technical SpecificationsDesign: 2-Axis articulating mount for securing wireless access points and directional antennas on walls. Designed to allowdirectional antenna to articulate in both azimuth and elevation. Works with most vendors' access points and antennas.Performance: +/- 45° antenna pointing, up and down, right and leftIncludes T-bar bracket for attaching most vendors’ APsIncludes universal antenna mounting plateConstruction: 14 ga. white, powder-coated steelSize: 9 inches by 11 inches by 6.25 inches (229 mm by 280 mm by 159 mm)

Measurements (Maximum values):

• Height: 9 in.• Width: 11 in.• Depth: 6.25 in.• Item Weight: 4.75 in.• Shipping Weight: 6 lbs.

Includes(4) 8-32 x 7/16" screws(4) 8-32 x 1/4" screws(2) 6-32 x 1/4" screws(1) T-bar(2) Wire tiesInstallation instructionsApproximate shipping weight: 6 lbs.

91

Page 92: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1303&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1013-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1013-00_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

92

Page 93: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1013-COVER2-Axis Articulating AP/Antenna Mount: White cover

Category: Wall and Hard Ceiling - Surface Mount - Surface Mount - Enclosures

2-axis Articulating AP and antenna mount for most manufacturers’ APs anddirective (or patch) antennas on pillars/walls. The 1013 is attached to the wall,and AP and antenna are attached to the articulating mount. Mount can beswiveled on two axes to provide the desired down-tilt and azimuth coverage ofthe directive antenna. The 1013 with the directive antenna can be used to createzones of coverage within stadiums, high-density auditoriums, and classrooms.Includes paintable vanity cover.

Features & Benefits

Excellent for stadiums, high-density auditoriums, and larger classroomsSwivels on two axes to provide down-tilt and azimuth coverage desiredDesigned for mounting most vendors enterprise wireless access points with external antennas on the wall or ceilingDesigned for high-density WiFi installationsCan be mounted over telecommunications outlet

Technical SpecificationsDesign: 2-Axis articulating mount for securing wireless access points and directional antennas on walls. Designed to allowdirectional antenna to articulate in both azimuth and elevation. Works with most vendors' access points and antennas. With vanitycover to conceal access point and antenna.Performance: Articulating antenna plate enables +/- 45° antenna pointing, up and down, right and left. Vanity cover is transparentto wireless signalIncludes T-bar bracket for attaching most vendors’ APsConstruction: 14 ga. white, powder-coated steelIncludes attachable, paintable, white UL94-5VA ABS plastic vanity coverSize: 9 inches by 11 inches by 6.25 inches (229 mm by 280 mm by 159 mm)Vanity cover size: 11.5 inches by 10.25 inches by 7.25 inches (292 mm by 260 mm by 184 mm)

Measurements (Maximum values):

• Height: 9 in.• Width: 11 in.• Depth: 6.25 in.• Item Weight: 7 lbs.• Shipping Weight: 7 lbs.

93

Page 94: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(4) 8-32 x 1/4" screws(1) Vanity Cover(2) 6-32 x 1/4" screws(1) T-bar(2) Wire tiesInstallation InstructionsShipping weight: 7 lbs.

Videos - https://www.youtube.com/user/oberoninc1013-COVER Installation Video View at https://youtu.be/CLC5WnzcFac

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1821&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1013-COVER_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1013-COVER_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

94

Page 95: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1014-001-Axis Articulating AP/Antenna Mount: White cover

Category: Wall and Hard Ceiling - Surface Mount - Surface Mount - Enclosures

Oberon’s Model 1014 is an articulating wall mount for most wireless accesspoints and directional antennas. Provides 1 axis articulating mount fordirectional antenna for up to a 45-degree tilt. The Model 1014-00 includes awireless signal transparent paintable cover, making it simple to customize thecolor of the access point compliment interior color schemes. Coloring the coverdoes not void the manufacturer’s warranty.

Features & Benefits

Swivels on one axis to provide down-tilt and azimuth coverage desiredDesigned for mounting most vendors enterprise wireless access points with external antennas on the wall or ceilingDesigned for high-density WiFi installationsCan be mounted over telecommunications outlet

Technical SpecificationsDesign: 1 Axis articulating mount for securing wireless access points and directional antennas on walls. Designed to allowdirectional antenna to articulate in elevation. Works with most vendors' access points and antennas. With vanity cover to concealaccess point and antenna.Performance: Articulating antenna plate enables +/- 45° antenna pointing, up and down. Vanity cover is transparent to wirelesssignalIncludes T-bar bracket for attaching most vendors’ APsConstruction: 16 ga. galvanized steelIncludes Oberon model 33-ANT-COVER attachable, paintable, white UL94-5VA ABS plastic vanity coverSize: 10.8 inches by 8 inches by 4.4 inches (274mm by 203mm by 114mm)Vanity Cover size: 11.3 inches by 10.1 inches by 7.6 inches (287mm by 257m by 195mm)

Measurements (Maximum values):

• Height: 10.8 in.• Width: 8 in.• Depth: 4.4 in.• Item Weight: 6 lbs.• Shipping Weight: 6 lbs.

Includes(1) Adjustable mounting bracket(1) White vanity cover(4) Screw head caps(1) T-bar bracketShipping weight: 6 lbs. per unit

95

Page 96: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1987&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1014-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1014-00_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

96

Page 97: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1015-0011" ABS AP Lock-box: Solid door

Category: Wall and Hard Ceiling - Surface Mount - Surface Mount - Enclosures

Compact, non-metallic enclosure secures and protects APs in residence halls,hotels, retail locations and other indoor venues. This rugged ABS plasticenclosure is virtually transparent to wireless signals so APs with integratedantennas or small detachable antennas may be protected. The box can bemounted directly over the telecommunication outlet, and cable raceway orconduit can be conveniently terminated.

Features & Benefits

Accommodates most vendors' APsLocking, fully-hinged doorSimplify code, industry directives, policy, and aesthetics compliance

Technical SpecificationsDesign: AP enclosure designed to be surface mounted on hard-lid ceilings or walls. Designed to accommodate APs with integratedor non-detachable antennas from most vendors.Performance: Ventilated, paintable, impact-resistant ABS plastic enclosure is virtually transparent to wireless signalsOberon Skybar-shaped, locking, fully-hinged door, keyed alikeUniversal T-bar for most vendors’ APsOpening in back allows for placement directly over outletTwistouts in sidewalls for conduit or racewayConstruction: UL 94-HB Classified ABS; textured white body and doorAP max. operating temperature should be de-rated by 9° C inside the enclosureSize: 11.1 inches by 11.1 inches by 4.4 inches (282 mm by 282 mm by 112 mm)

Measurements (Maximum values):

• Height: 11.1 in.• Width: 11.1 in.• Depth: 4.4 in.• Item Weight: 3 lbs.• Shipping Weight: 4 lbs.

Includes(1) Unit(1) Internal universal access point mounting T-bar bracket(2) Keys for lockInstallation instructions

Available Accessories39-1015-PLATE - Model 1015 Metal Back Plate

97

Page 98: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1258&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1015-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1015_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Application_Note_Wireless_Coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

98

Page 99: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1015-C11" ABS AP Lock-box: T-bar, Translucent door

Category: Wall and Hard Ceiling - Surface Mount - Surface Mount - Enclosures

Compact, non-metallic enclosure secures and protects APs in residence halls,hotels, retail locations and other indoor venues. This rugged ABS plasticenclosure is virtually transparent to wireless signals so APs with integratedantennas or small detachable antennas may be protected. The box can bemounted directly over the telecommunication outlet, and cable raceway orconduit can be conveniently terminated.

Features & Benefits

Accommodates most vendors' enterprise access pointsLocking, fully-hinged doorSimplify code, industry directives, policy, and aesthetics compliance

Technical SpecificationsDesign: Wireless access point enclosure with translucent, frosted door, designed to be surface mounted on hard-lid ceilings orwalls. Designed to accommodate wireless access points with integrated or non-detachable antennas from most vendors.Performance: Ventilated, paintable, impact-resistant ABS plastic enclosure is virtually transparent to wireless signalsOberon Skybar-shaped locking, fully-hinged door, keyed alikeUniversal T-bar for most vendors’ access pointsOpening in back allows for placement directly over outletTwistouts in sidewalls for conduit or raceway Construction: UL 94-HB Classified ABS; box is white; door is translucent, frostedAP max. operating temperature should be de-rated by 9° C inside the enclosureSize: 11.1 inches by 11.1 inches by 4.4 inches (282 mm by 282 mm by 112 mm)

Measurements (Maximum values):

• Height: 11.1 in.• Width: 11.1 in.• Depth: 4.4 in.• Item Weight: 3 lbs.• Shipping Weight: 4 lbs.

Includes(1) Unit(1) Internal universal access point mounting T-bar bracket(2) Keys for lockInstallation instructions

Available Accessories39-1015-PLATE - Model 1015 Metal Back Plate

99

Page 100: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1259&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1015-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1015_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Application_Note_Wireless_Coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

100

Page 101: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1016-0018" Polycarbonate AP Lock-box: Solid door

Category: Wall and Hard Ceiling - Surface Mount - Surface Mount - Enclosures

Non-metallic enclosure secures and protects APs, wireless routers, and multiplenetworking components in offices, hotels, retail locations and other indoorvenues. This rugged polycarbonate plastic enclosure is virtually transparent towireless signals so APs with integrated antennas or small detachable antennasmay be protected. The box can be mounted directly over the telecom outlet, andpower strip and cabling can be neatly concealed. Cable raceway or conduit canbe conveniently terminated.

Features & Benefits

Accommodates most vendors' enterprise access points with external antennasLocking, fully-hinged doorSimplify code, industry directives, policy, and aesthetics compliance

Technical SpecificationsDesign: Wireless access point enclosure designed to be surface mounted on hard-lid ceilings or walls. Designed to accommodatecable modems, wireless routers, and wireless access points with integrated or non-detachable antennas and external antennasfrom most vendors.Performance: Ventilated, paintable, impact-resistant polycarbonate plastic enclosure is virtually transparent to wireless signalsOberon Skybar-shaped locking, fully-hinged door, keyed alikeUniversal T-bar for most vendors’ access pointsOpening in back allows for placement directly over outletTwistouts in sidewalls for conduit or racewayConstruction: UL 94-V0 Classified polycarbonate; textured white body and doorSize: 12 inches by 18 inches by 5.15 inches (305mm by 457 mm by 131 mm)

Measurements (Maximum values):

• Height: 12 in.• Width: 18 in.• Depth: 5.15 in.• Item Weight: 5 lbs.• Shipping Weight: 6 lbs.

101

Page 102: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(1) Internal universal access point mounting T-bar bracket(2) Keys for lock(2) 1/2" Nylon spacer(2) #6 x 7/8" screw(2) #6 x 1/4 screwInstallation instructions

Available Accessories39-1016-SPKRMNT - Mounting bracket assembly for the Model 1016 series39-1016-ANTPLATE - Articulating Antenna Mount for Oberon Model 1016 Series

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1304&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1016-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1016_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Positioning_your_wireless_router_with_Oberon_Network_Cabinet.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

102

Page 103: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1016-ANTPLATE18" Polycarbonate AP Lock-box: Solid door with articulating

antenna bracketCategory: Wall and Hard Ceiling - Surface Mount - Surface Mount - Enclosures

Features & Benefits

Accommodates most vendors' enterprise access points with external antennasLocking, fully-hinged doorSimplify code, industry directives, policy, and aesthetics compliance

Technical SpecificationsDesign: Wireless access point enclosure designed to be surface mounted on hard-lid ceilings or walls. Designed to accommodatecable modems, wireless routers, and wireless access points with integrated or non-detachable antennas and external antennasfrom most vendors.Performance: Ventilated, paintable, impact-resistant polycarbonate plastic enclosure is virtually transparent to wireless signalsOberon Skybar-shaped locking, fully-hinged door, keyed alikeUniversal T-bar for most vendors’ access pointsDirect mounting features for Cisco Access pointsArticulating antenna mountOpening in back allows for placement directly over outletTwistouts in sidewalls for conduit or racewayConstruction: UL 94-V0 Classified polycarbonate; textured white body and doorSize: 12 inches by 18 inches by 5.15 inches (305mm by 457 mm by 131 mm)

Measurements (Maximum values):

• Height: 12 in.• Width: 18 in.• Depth: 5.15 in.• Item Weight: 5 lbs.• Shipping Weight: 6 lbs.

103

Page 104: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(1) Internal universal access point mounting T-bar bracket(1) Articulating Antenna Mount(2) Keys for lock(2) 1/2" Nylon spacer(2) #6 x 7/8" screw(2) #6 x 1/4 screwInstallation instructions

Available Accessories39-1016-SPKRMNT - Mounting bracket assembly for the Model 1016 series

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=3177&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1016-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1016-ANTPLATE_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

104

Page 105: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1016-C18" Polycarbonate AP Lock-box: T-bar, Translucent door

Category: Wall and Hard Ceiling - Surface Mount - Surface Mount - Enclosures

Non-metallic enclosure secures and protects APs, wireless routers, and multiplenetworking components in offices, hotels, retail locations and other indoorvenues. This rugged polycarbonate plastic enclosure is virtually transparent towireless signals so APs with integrated antennas or small detachable antennasmay be protected. The box can be mounted directly over the telecom outlet, andpower strip and cabling can be neatly concealed. Cable raceway or conduit canbe conveniently terminated.

Features & Benefits

Accommodates most vendors' enterprise access points with external antennasLocking, fully-hinged doorSimplify code, industry directives, policy, and aesthetics compliance

Technical SpecificationsDesign: Wireless access point enclosure designed to be surface mounted on hard-lid ceilings or walls. Designed to accommodatecable modems, wireless routers, and wireless access points with integrated or non-detachable antennas and external antennasfrom most vendors.Performance: Ventilated, paintable, impact-resistant polycarbonate plastic enclosure is virtually transparent to wireless signalsOberon Skybar-shaped locking, fully-hinged door, keyed alikeUniversal T-bar for most vendors’ access pointsOpening in back allows for placement directly over outletTwistouts in sidewalls for conduit or racewayConstruction: UL 94-V0 Classified polycarbonate. Body is white, door is translucent, frostedSize: 12 inches by 18 inches by 5.15 inches (305mm by 457 mm by 131 mm)

Measurements (Maximum values):

• Height: 12 in.• Width: 18 in.• Depth: 5.15 in.• Item Weight: 5 lbs.• Shipping Weight: 6 lbs.

105

Page 106: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(1) Internal universal access point mounting T-bar bracket(2) Keys for lock(2) 1/2" Nylon spacer(2) #6 x 7/8" screw(2) #6 x 1/4 screwInstallation instructions

Available Accessories39-1016-SPKRMNT - Mounting bracket assembly for the Model 1016 series39-1016-ANTPLATE - Articulating Antenna Mount for Oberon Model 1016 Series

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1305&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1016-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1016_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Application_Note_Wireless_Coverage_FAQ.pdf

Positioning the Wireless Router - oberoninc.com/images/WebDocs/Positioning_your_wireless_router_with_Oberon_Network_Cabinet.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

106

Page 107: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1017-BLSmall Wall Mount AP Protective Non-Metallic Box

Category: Wall and Hard Ceiling - Surface Mount - Surface Mount - Enclosures

Hotels and residence halls often require APs in each room. Many compact APsfasten to a telecommunications outlet low on the wall, vulnerable to tampering,disconnect, or accidental damage. This compact, non-metallic plastic boxprotects the AP and cables connected to it. Deep enough to surface mount APswithout a telecommunications outlet in the wall, the low-profile 1017 is moldedfrom durable ABS plastic, virtually transparent to the wireless signal. Box coverhas tamper-resistant screws.

Features & Benefits

Impact-resistant, ABS plastic protective box in black (1017-BL) or off-white (1017-WH), designed to protect smaller, wall-mountedaccess pointsIdeal for protecting wireless access points in hotel rooms and residence hallsMounts directly over access point attached to the wall, ABS plastic is virtually transparent to wireless signalsIncludes an internal AP standoff bracket, for surface mount applications without telecommunications outlet in the wallTamper-resistant hardware (torx screws) for coverLow profile (3.15”); fits behind desks or furniture

Technical SpecificationsDesign: Wireless access point enclosure designed to be surface-mounted on hard-lid ceilings or walls. Designed to accommodatesmaller wall mount wireless access points with integrated or non-detachable antennas, such as Cisco 702W access points.Performance: Ventilated, impact-resistant ABS plastic enclosure is virtually transparent to wireless signalsScrew on cover with tamper-resistant (torx) screwsInternal universal AP standoff bracket for surface mounting applications without outlet in the wallConstruction: UL94-5VA classified ABS plastic; beige body and coverExternal size: 6 inches by 10.1 inches by 3.15 inches (152mm by 256mm by 80mm). available internal dimensions 5.78 by 9.75 by2.91 inches (147mm by 248mm by 69mm)

Standards for SafetyUL-945VA ABS Material

Measurements (Maximum values):

• Height: 6 in.• Width: 10.1 in.• Depth: 3.15 in.• Item Weight: 2 lbs.• Shipping Weight: 9 lbs.

107

Page 108: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) ABS box and lid(1) Internal AP standoff bracket(4) AP standoff bracket screws(6) #4 x 1/2" Black torx lid screw(6) #4 x 1/2" Black Philips lid screw(4) #6 x 1/4" Philips AP mounting screw(4) #2 x 1/2" Philips mounting bracket screwInstallation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2607&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1017-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1017-00_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

108

Page 109: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1017-WHSmall Wall Mount AP Protective Non-Metallic Box

Category: Wall and Hard Ceiling - Surface Mount - Surface Mount - Enclosures

Hotels and residence halls often require APs in each room. Many compact APsfasten to a telecommunications outlet low on the wall, vulnerable to tampering,disconnect, or accidental damage. This compact, non-metallic plastic boxprotects the AP and cables connected to it. Deep enough to surface mount APswithout a telecommunications outlet in the wall, the low-profile 1017 is moldedfrom durable ABS plastic, virtually transparent to the wireless signal. Box coverhas tamper-resistant screws.

Features & Benefits

Impact-resistant, ABS plastic protective box in black (1017-BL) or off-white (1017-WH), designed to protect smaller, wall-mountedaccess pointsIdeal for protecting wireless access points in hotel rooms and residence hallsMounts directly over access point attached to the wall, ABS plastic is virtually transparent to wireless signalsIncludes an internal AP standoff bracket, for surface mount applications without telecommunications outlet in the wallTamper-resistant hardware (torx screws) for coverLow profile (3.15”); fits behind desks or furniture

Technical SpecificationsWireless access point enclosure designed to be surface-mounted on hard-lid ceilings or walls. Designed to accommodate smallerwall mount wireless access points with integrated or non-detachable antennas such as Cisco 702W or 1810W access points.Performance: Ventilated, paintable, impact-resistant ABS plastic enclosure is virtually transparent to wireless signalsScrew on cover with tamper-resistant (torx) screwsInternal universal AP standoff bracket for surface mounting applications without outlet in the wallConstruction: UL94-5VA classified ABS plastic; black body and coverExternal size: 6 inches by 10.1 inches by 3.15 inches (152mm by 256mm by 80mm). Available internal dimensions 5.78 by 9.75 by2.91 inches (147mm by 248mm by 69mm)

Standards for SafetyUL-945VA ABS Material

Measurements (Maximum values):

• Height: 6 in.• Width: 10.1 in.• Depth: 3.15 in.• Item Weight: 2 lbs.• Shipping Weight: 9 lbs.

109

Page 110: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) ABS box and lid(1) Internal AP standoff bracket(4) AP standoff bracket screws(6) #4 x 1/2" Black torx lid screw(6) #4 x 1/2" Black Philips lid screw(4) #6 x 1/4" Philips AP mounting screw(4) #2 x 1/2" Philips mounting bracket screwInstallation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2022&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1017-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1017-00_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

110

Page 111: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1018-WHWall Mount, Polycarbonate AP Enclosure

Category: Wall and Hard Ceiling - Surface Mount - Surface Mount - Enclosures

Aesthetic and economical, Oberon’s Model 1018 is a rugged enclosure designedto protect most vendors’ APs in many environments. The 1018 is injectionmolded with UV-stabilized polycarbonate, and includes a captured gasket in thecover to provide capability for outdoor installations. The screw-on, whitepolycarbonate cover is virtually transparent to wireless signals. Internal bracketis designed to simplify access point installation.

Features & Benefits

Impact-resistant, white, polycarbonate enclosure for most vendors' APsArchitectural design motif resembling lighting luminaireIdeal for protecting APs in indoor and outdoor locationsAP status LED is visible through coverIncludes wireless symbol label for user to attach to cover (optionally)

Technical SpecificationsDesign: Round AP enclosure designed to be surface mounted on hard-lid ceilings or walls. Resembles a common lightingluminaire. Designed to accommodate APs with integrated or non-detachable antennas. Large enough for Cisco 3500/3600 seriesAPs, NOT large enough for Cisco 2800/3800 APs.Performance: UV-stabilized, impact-resistant, polycarbonate enclosure suitable for indoor and outdoor use. Virtually transparentto wireless signal.Screw on cover with gasket and screw gasketsfour conduit drill points around exteriorAttachable “WiFi” symbol stickerInternal universal T-bar bracket and Cisco mounting plate.Construction: White polycarbonate plastic body and cover; cover is translucent, such that AP status LEDs are visibleAP maximum operating temperature should be de-rated by 7° C when mounted in enclosure.External size: 11.9 inch diameter by 4 inches deep (302mm by 100mm).

Measurements (Maximum values):

• Height: 11.9 in.• Width: 11.9 in.• Depth: 4 in.• Item Weight: 2.5 lbs.• Shipping Weight: 4 lbs.

111

Page 112: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Polycarbonate housing and cover(1) Universal AP T-bar mount and hardware(1) Cisco AP mounting plate(4) #6 x 1/4" Philips screw(4) #8 x 1/4" Philips screw(3) Cover screws(3) Nylon retaining washers(3) Cover screw grommets(1) Rear foam gasket(1) Wireless symbol label(1) Installation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2351&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1018-WH_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1018-00_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

112

Page 113: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1030-00Steel Surface Mount AP Wall Enclosure-ABS dome

Category: Wall and Hard Ceiling - Surface Mount - Surface Mount - Enclosures

This "hard lid" or wall mount enclosure provides a secure, aesthetic, convenientmounting solution for APs from most vendors. The enclosure has a low profile,impact-resistant ABS plastic dome so that APs with integrated or non-detachableantennas can be secured in otherwise unsecured spaces. White, texturedpowder-coated steel box provides greatest physical protection.

Features & Benefits

Designed for securing leading vendors enterprise wireless access points and DAS remotesLocking, fully-hinged door, with impact-resistant plastic domeSimplify code, industry directives, policy, and aesthetics compliance

Technical SpecificationsDesign: Wireless access point enclosure designed to be surface-mounted on hard-lid ceilings or walls. Designed to accommodatewireless access points with integrated or non-detachable antennas. Plastic dome in door.Performance: UL Listed and designed to meet NEC300-22 and 300-23 for air-handling space installations. Dome is transparent towireless signals.Fully-hinged locking door, keyed alikeConstruction: 16 ga. back-box, 14 ga. door frame, powder-coated steel; impact-resistant dome is UL 94-5VA classified ABS plasticMaximum weight inside enclosure is 25 lbs.AP max. operating temperature should be de-rated by 10° C inside the enclosureSize: 17 inches by 17 inches by 3.5 inches (432 mm by 432 mm by 89 mm) (total depth), the dome is 12 inches by 12 inches by 2inches (305 mm by 305 mm by 51 mm)

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General Requirements

Measurements (Maximum values):

• Height: 17 in.• Width: 17 in.• Depth: 3.5 in.• Item Weight: 13 lbs.• Shipping Weight: 16 lbs.

113

Page 114: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) T-bar mount(1) ½" Trade size conduit connector(2) Keys for lock(4) #6-32 x 3/16 screws(4) #8-32 x 3/16 screwsMounting instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1262&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1030-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1030-00_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Application_Note_Wireless_Coverage_FAQ.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

114

Page 115: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1042-CCOAPRecessed Ceiling AP Install Kit- Old construction

Category: Wall and Hard Ceiling - Recess Mount

Model 1042-CCOAP provides the simplest way to recess APs into the ceiling foran aesthetic, professional installation. A cutout is made in the ceiling and theback-box is fastened to the ceiling (remodel). The AP fastens to the AP-specifictrim, and the trim to the back-box. The AP is recessed into the ceiling much likea recessed light fixture. AP trim can be easily swapped for new trim if the APbrand or model changes in the future. See specs for AP-specific model names.Patent pending

Features & Benefits

Conveniently and quickly install APs in hard ceiling environmentsWhite, powder-coated, beveled AP trim provides a professional finish

Technical SpecificationsDesign: Economical, recessed hard ceiling or wall installation kit for APs. For pre-existing drywall, sheetrock, gypsum board wallsor ceiling (remodeling or old construction). AP mounts in interchangeable bracket and trim, providing a professional finish.Designed for Cisco 2600, 2700, 3500, 3600, 3700 seriesPerformance: UL listed for low voltage applications, and designed to meet NEC300-22 and 300-23 for plenum installations. De-rateAP operating temperature range by 10°C when mounted in enclosureAP bracket and trim is interchangeable for other APs, without removing back-boxFirestop grommet for insertion into back-box, large enough for 2 Cat6A cables1" trade size knockouts in two wallsSwivel fasteners secure enclosure into pre-existing hard ceiling/wall panels 3/4" thick or lessConstruction: 20 ga. galvanized steel back-box, and white, powder-coated 20 ga. steel trim. Solid back-box fills opening behind AP,creating an effective fire, smoke and dust barrier to simplify ICRA complianceMaximum weight inside enclosure is 25lbsSize: 14.67 inches by 14.67 inches by 3 inches (373 mm by 373 mm by 76mm). Back-box is 11 inches by 11 inches x 3inches

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General Requirements

Measurements (Maximum values):

• Height: 11 in.• Width: 11 in.• Depth: 3 in.• Item Weight: 5 lbs.• Shipping Weight: 6 lbs.

115

Page 116: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(4) #6-32 X 3/4“ white screw(4) #8-32 X 1/4" screw(2) #8-32 X 1/4" M/F standoff(2) #8-32 Nuts(1) 1” Conduit fitting with nut(1) Firestop grommet(1) Installation instructions

Available Accessories37-104x-BLANK-F - Blank Trim Plate

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1664&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1042-CCOAP_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1042_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

116

Page 117: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1042-CCOAP3800Recessed Ceiling AP Install Kit- Old construction

Category: Wall and Hard Ceiling - Recess Mount

Model 1042-CCOAP3800 provides the simplest way to recess APs into the ceilingfor an aesthetic, professional installation. A cutout is made in the ceiling and theback-box is fastened to the ceiling (remodel). The AP fastens to the AP-specifictrim, and the trim to the back-box. The AP is recessed into the ceiling much likea recessed light fixture. AP trim can be easily swapped for new trim if the APbrand or model changes in the future. See specs for AP-specific model names.Patent pending

Features & Benefits

Conveniently and quickly install APs in hard ceiling environmentsWhite, powder-coated, beveled AP trim provides a professional finish

Technical SpecificationsDesign: Economical, recessed hard ceiling or wall installation kit for APs. For pre-existing drywall, sheetrock, gypsum board wallsor ceiling (remodeling or old construction). AP mounts in interchangeable bracket and trim, providing a professional finish.Designed for Cisco 2800 and 3800 seriesPerformance: UL listed for low voltage applications, and designed to meet NEC300-22 and 300-23 for plenum installations. De-rateAP operating temperature range by 10°C when mounted in enclosureAP bracket and trim is interchangeable for other APs, without removing back-boxFirestop grommet for insertion into back-box, large enough for 2 Cat6A cables1" trade size knockouts in two wallsSwivel fasteners secure enclosure into pre-existing hard ceiling/wall panels 3/4" thick or lessConstruction: 20 ga. galvanized steel back-box, and white, powder-coated 20 ga. steel trim. Solid back-box fills opening behind AP,creating an effective fire, smoke and dust barrier to simplify ICRA complianceMaximum weight inside enclosure is 25lbsSize: 14.67 inches by 14.67 inches by 3 inches (373 mm by 373 mm by 76mm). Back-box is 11 inches by 11 inches x 3inches

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General Requirements

Measurements (Maximum values):

• Height: 11 in.• Width: 11 in.• Depth: 3 in.• Item Weight: 5 lbs.• Shipping Weight: 6 lbs.

117

Page 118: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(4) #6-32 X 3/4“ white screw(4) #8-32 X 1/4" screw(2) #8-32 X 1/4" M/F standoff(2) #8-32 Nuts(1) 1” Conduit fitting with nut(1) Firestop grommet(1) Installation instructions

Available Accessories37-104x-BLANK-F - Blank Trim Plate

Videos - https://www.youtube.com/user/oberoninc1042-CCOAP3800 Installation Video View at https://youtu.be/r9sGqcuIVfc

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2919&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1042-CCOAP_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1042_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

118

Page 119: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1042-FLRecessed Hard Ceiling AP Installation Kit

Category: Wall and Hard Ceiling - Recess Mount

Model 1042 provides the simplest way to recess APs into the ceiling for anaesthetic, professional installation. A cutout is made in the ceiling and the back-box is fastened into the ceiling (remodel). The AP fastens into the back-box. The1042-FL has a low profile textured white ABS plastic cover which snaps over therecessed back-box. The ABS plastic cover is virtually transparent to wirelesssignals. The cover is paintable and can be can be easily swapped out for otherOberon trim styles. UL Listed.

Features & Benefits

Economical hard ceiling recess mount for Cisco APsLow profile snap on white ABS plastic cover is paintable, so AP virtually disappears into the wallIdeal for concealing AP in architecturally sensitive hard ceiling venues

Technical SpecificationsDesign: Economical, recessed hard ceiling or wall installation kit designed for APs with integrated antennas. Low profile texturedwhite plastic ABS cover provides a professional finish. For pre-existing drywall, sheetrock, gypsum board walls or ceiling(remodeling or old construction). Designed for most vendors' APsPerformance: UL listed for low voltage applications, and designed to meet NEC300-22 and 300-23 for plenum installations. De-rateAP operating temperature range by 10°C when mounted in enclosureABS plastic cover is captured in back-box with tool-less spring retainer and is virtually transparent to wireless signalsFirestop grommet for insertion into back-box, large enough for 2 Cat6A cables1" trade size knockouts in two wallsSwivel fasteners secure enclosure into pre-existing hard ceiling/wall panels ¾" thick or lessConstruction: 20 ga. galvanized steel back-box, and white, powder-coated 20 ga. steel trim. UL94-5VA ABS plastic cover. Solidback-box fills opening behind AP, creating an effective fire, smoke and dust barrier to simplify ICRA complianceMaximum weight inside enclosure is 25lbs.Size: Back-box is 11 inches by 11 inches x 3 inches (279 mm by 279 mm by 76mm). ABS Plastic cover is 13.5" x 13.5" x 0.5"

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General Requirements

Measurements (Maximum values):

• Height: 11 in.• Width: 11 in.• Depth: 3 in.• Item Weight: 5 lbs.• Shipping Weight: 6 lbs.

119

Page 120: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(2) Wall/ceiling back-box(4) #6-32 X 1/2“ screw(2) Torsion spring(2) #8-32 X 1/4" screw(1) ABS plastic cover(1) AP mounting bracket(1) 1" Conduit fitting with nut(1) Firestop grommet(1) Support wire(1) Installation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=3158&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1042-FL_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1042-FL_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

120

Page 121: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1043-CCOAPRecessed Ceiling AP Install Kit- New construction

Category: Wall and Hard Ceiling - Recess Mount

Model 1043-CCOAP offers the simplest way to recess APs into the ceiling for anaesthetic, professional installation. A cutout is made in the ceiling and the back-box is fastened to the ceiling joists (new construction). The AP fastens to a AP-specific trim, and the trim to the back-box. The AP is recessed into the ceilingmuch like a recessed light fixture. Access point trim can be swapped easily fornew trim if the AP brand or model changes in the future. See specs for AP-specific model names.Patent pending

Features & Benefits

Conveniently and quickly install APs in hard ceiling environmentsWhite, powder-coated, beveled access point trim provides a professional finish

Technical SpecificationsDesign: Economical, recessed hard ceiling or wall installation kit designed for APs with integrated antennas. AP mounts ininterchangeable bracket and trim, providing a professional finish. For new ceilings and walls (new construction). Designed forCisco APsPerformance: UL Listed for low-voltage applications, and designed to meet NEC300-22 and 300-23 for plenum installations. De-rate AP operating temperature range by 10°C when mounted in enclosureAP bracket and trim is interchangeable for other APs, without removing back-boxFirestop grommet for insertion into back-box, large enough for 2 Cat6A cables1" trade size knockouts in two wallsCeiling/wall bridges secure enclosure into ceiling joistsConstruction: 20 ga. galvanized steel back-box, and white, powder-coated 20 ga. steel trim; solid back-box fills opening behindaccess point, creating an effective fire, smoke, and dust barrier to simplify ICRA complianceMaximum weight inside enclosure is 25 lbs.AP max. operating temperature should be de-rated by 10° C inside the enclosureSize: 14.67 inches by 14.67 inches by 3 inches (373 mm by 373 mm by 76mm); back-box is 11 inches by 11 inches x 3 inches

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General Requirements

Measurements (Maximum values):

• Height: 11 in.• Width: 11 in.• Depth: 3 in.• Item Weight: 5 lbs.• Shipping Weight: 6 lbs.

121

Page 122: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Galvanized back-box(1) Vendor-specific access point trim; white, powder-coated (See Configurations)(1) AP mounting bracket(4) Trim fastening hardware(1) Firestop cable grommet for back-box, large enough for 2 category 6A cablesInstallation Instructions

Available Accessories37-104x-BLANK-F - Blank Trim Plate

Videos - https://www.youtube.com/user/oberoninc1043 Installation Video View at https://youtu.be/K6q8_wWA-Bg

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1980&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1043-CCOAP_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1043-XX_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

122

Page 123: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1043-CCOAP3800Recessed Ceiling AP Install Kit- New construction

Category: Wall and Hard Ceiling - Recess Mount

Model 1043-CCOAP3800 offers the simplest way to recess APs into the ceiling foran aesthetic, professional installation. A cutout is made in the ceiling and theback-box is fastened to the ceiling joists (new construction). The AP fastens to aAP-specific trim, and the trim to the back-box. The AP is recessed into the ceilingmuch like a recessed light fixture. AP trim can be swapped easily for new trim ifthe AP brand or model changes in the future. See specs for AP-specific modelnames.Patent pending

Features & Benefits

Conveniently and quickly install APs in hard ceiling environmentsWhite, powder-coated, beveled AP trim provides a professional finish

Technical SpecificationsDesign: Economical, recessed hard ceiling or wall installation kit designed for APs with integrated antennas. AP mounts ininterchangeable bracket and trim, providing a professional finish. For new ceilings and walls (new construction). Designed forCisco 3800 APs.Performance: UL Listed for low-voltage applications, and designed to meet NEC300-22 and 300-23 for plenum installations.AP bracket and trim is interchangeable for other APs, without removing back-boxFirestop grommet for insertion into back-box, large enough for 2 Cat6A cables1" trade size knockouts in two wallsCeiling/wall bridges secure enclosure into ceiling joistsConstruction: 20 ga. galvanized steel back-box, and white, powder-coated 20 ga. steel trim; solid back-box fills opening behind AP,creating an effective fire, smoke, and dust barrier to simplify ICRA complianceMaximum weight inside enclosure is 25 lbs.AP max. operating temperature should be de-rated by 10° C inside the enclosureSize: 14.67 inches by 14.67 inches by 3 inches (373 mm by 373 mm by 76mm); back-box is 11 inches by 11 inches x 3 inches

Standards for SafetyUL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General Requirements

Measurements (Maximum values):

• Height: 11 in.• Width: 11 in.• Depth: 3 in.• Item Weight: 5 lbs.• Shipping Weight: 6 lbs.

123

Page 124: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Galvanized back-box(1) Vendor-specific AP trim; white, powder-coated (See Configurations)(1) AP mounting bracket(4) Trim fastening hardware(1) Firestop cable grommet for back-box, large enough for 2 category 6A cablesInstallation Instructions

Available Accessories37-104x-BLANK-F - Blank Trim Plate

Videos - https://www.youtube.com/user/oberoninc1043 Installation Video View at https://youtu.be/K6q8_wWA-Bg

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2932&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1043-CCOAP_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1043-XX_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

124

Page 125: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1051-00Recessed Ceiling/Wall AP Mount

Category: Wall and Hard Ceiling - Recess Mount

Locking hard lid ceiling or wall mount enclosure is designed for wireless APs andDAS remote units with detachable antennas. This aesthetic, white powder-coatedsteel enclosure has an 17.5” square bezel which fastens into the wall andsimplifies AP moves, adds, and changes. The -00 model has openings in the doorto mount up to seven external antennas. Interchangeable retrofit doors allowcurrent owners to upgrade to new AP or antenna solutions from different vendorsby swapping doors.

Features & Benefits

Recessed, hard lid ceiling or wall enclosure for securing wireless AP and DAS remotes with detachable antennasUniversal T-bar mounting bracket allows easy installation of most vendors' APsFully-hinged locking door, keyed alikeInterchangeable doors permit simple migration to new APs and antennasEnclosure back-box is effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: 4.5 inch deep AP enclosure designed for recess installation in hard-lid ceilings (drywall, plaster and lath, stucco, block,core plank, etc.). Internal T-bar accommodates APs from most manufacturersThis is a steel enclosure so antennas MUST be mounted externally on the door, or AP mounted in the door. Mount up to (7)external antennas on the door using the bulkhead connector kit for dipole antennas (Oberon P/N 35-BULKHD-KIT) or Oberon 34-ZDUAL or 34-DMDUAL antennasPerformance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved, OPM-0110-13.De-rate AP operating temperature range by 6°C when mounted in enclosureEnclosure must be fastened to ceiling using suitable hardwareFully hinged locking door, keyed alike. Doors are interchangeableConstruction: 16 ga. back-box, 14 ga. door, textured white powder-coated steelSize: Flange is 17.5 inches by 17.5 inches (445 mm by 445 mm), enclosure is 12.5 inches by 12.5 inches by 4.5 inches deep (318mm by 318 mm by 114 mm), 4 inches (101 mm) useful depth with universal T-bar bracket in placeMaximum weight to be installed inside enclosure is 25 lbs

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUL Listed and designed to meet National Electric Code Paragraphs 300-22 and 300-23 for installation in the above-ceiling spaceUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

125

Page 126: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 17.5 in• Width: 17.5 in• Depth: 4.5 in.• Item Weight: 16 lbs.• Shipping Weight: 17 lbs.

Includes(1) Unit per carton(1) Internal universal AP mounting T-bar bracket(4) Hanger wires(1) Cable egress firestop Kit (1" trade size conduit connector, and firestop grommet)(2) Keys for lock(4) White cosmetic screw caps and (4) #10 ceiling/wall attachment screwsInstallation instructions

Available Accessories34-BMANT24 - 2.4 GHz Single Band WiFi Antenna: NEMA4 Enclosures34-BMANT5 - 5 GHz Single Band WiFi Antenna: NEMA4 Enclosures34-ZDUAL - Dual Band WiFi Antennas: Oberon Enclosures, RPTNC

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1267&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1051-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1051-00_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

126

Page 127: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1051-CCOANTRecessed Ceiling/Wall AP Mount - Cisco antenna

Category: Wall and Hard Ceiling - Recess Mount

Features & Benefits

Recessed, hard lid ceiling or wall enclosure for securing wireless access points and DAS remotes with detachable antennasUniversal T-bar mounting bracket allows easy installation of most vendors' APsFully-hinged locking door, keyed alikeInterchangeable doors permit simple migration to new APs and antennasEnclosure back-box is effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: 4.5 inch deep AP enclosure designed for recess installation in hard-lid ceilings (drywall, plaster and lath, stucco, block,core plank, etc.). Internal T-bar accommodates APs from most manufacturersThis is a steel enclosure so antennas MUST be mounted externally on the door, or AP mounted in the door. Designed for Cisco1242, 1260 and 3500e APsPerformance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved, OPM-0110-13.De-rate AP operating temperature range by 6°C when mounted in enclosureEnclosure must be fastened to ceiling using suitable hardwareFully hinged locking door, keyed alike. Doors are interchangeableConstruction: 16 ga. back-box, 14 ga. door, textured white powder-coated steelSize: Flange is 17.5 inches by 17.5 inches (445 mm by 445 mm), enclosure is 12.5 inches by 12.5 inches by 4.5 inches deep (318mm by 318 mm by 114 mm), 4 inches (101 mm) useful depth with universal T-bar bracket in placeMaximum weight to be installed inside enclosure is 25 lbs

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUL Listed and designed to meet National Electric Code Paragraphs 300-22 and 300-23 for installation in the above-ceiling spaceUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

Measurements (Maximum values):

• Height: 17.5 in.• Width: 17.5 in.• Depth: 4.5 in.• Item Weight: 16 lbs.• Shipping Weight: 17 lbs.

127

Page 128: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit per carton(1) Internal universal AP mounting T-bar bracket(4) Hanger wires(1) Cable egress firestop Kit (1" trade size conduit connector, and firestop grommet)(2) Keys for lock(4) White cosmetic screw caps and (4) #10 ceiling/wall attachment screwsInstallation instructions

Available Accessories34-BMANT24 - 2.4 GHz Single Band WiFi Antenna: NEMA4 Enclosures34-BMANT5 - 5 GHz Single Band WiFi Antenna: NEMA4 Enclosures34-ZDUAL - Dual Band WiFi Antennas: Oberon Enclosures, RPTNC

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=3244&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1051-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1051-00_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

128

Page 129: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1051-CCOAPRecessed Ceiling/Wall AP Mount - Cisco APs

Category: Wall and Hard Ceiling - Recess Mount

Locking hard lid ceiling or wall mount enclosure is designed for wireless APs andDAS remote units with detachable antennas. This aesthetic, white powder-coatedsteel enclosure has an 17.5” square bezel which fastens into the wall andsimplifies access point moves, adds, and changes. The -00 model has openingsin the door to mount up to seven external antennas. Interchangeable retrofitdoors allow current owners to upgrade to new AP or antenna solutions fromdifferent vendors by swapping doors.

Features & Benefits

Recessed, hard lid ceiling or wall enclosure for securing wireless access points and DAS remotes with detachable antennasUniversal T-bar mounting bracket allows easy installation of most vendors' APsFully-hinged locking door, keyed alikeInterchangeable doors permit simple migration to new APs and antennasEnclosure back-box is effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: 4.5 inch deep AP enclosure designed for recess installation in hard-lid ceilings (drywall, plaster and lath, stucco, block,core plank, etc.). Internal T-bar accommodates APs from most manufacturersThis is a steel enclosure so antennas MUST be mounted externally on the door, or AP mounted in the door. Designed for Cisco2700, 3500, 3600 and 3700 series APsPerformance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved, OPM-0110-13.De-rate AP operating temperature range by 6°C when mounted in enclosureEnclosure must be fastened to ceiling using suitable hardwareFully hinged locking door, keyed alike. Doors are interchangeableConstruction: 16 ga. back-box, 14 ga. door, textured white powder-coated steelSize: Flange is 17.5 inches by 17.5 inches (445 mm by 445 mm), enclosure is 12.5 inches by 12.5 inches by 4.5 inches deep (318mm by 318 mm by 114 mm), 4 inches (101 mm) useful depth with universal T-bar bracket in placeMaximum weight to be installed inside enclosure is 25 lbs

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUL Listed and designed to meet National Electric Code Paragraphs 300-22 and 300-23 for installation in the above-ceiling spaceUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

129

Page 130: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 17.5 in• Width: 17.5 in• Depth: 4.5 in.• Item Weight: 16 lbs.• Shipping Weight: 17 lbs.

Includes(1) Unit per carton(1) Internal universal AP mounting T-bar bracket(4) Hanger wires(1) Cable egress firestop Kit (1" trade size conduit connector, and firestop grommet)(2) Keys for lock(4) White cosmetic screw caps and (4) #10 ceiling/wall attachment screwsInstallation instructions

Available Accessories34-BMANT24 - 2.4 GHz Single Band WiFi Antenna: NEMA4 Enclosures34-BMANT5 - 5 GHz Single Band WiFi Antenna: NEMA4 Enclosures34-ZDUAL - Dual Band WiFi Antennas: Oberon Enclosures, RPTNC

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2229&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1051-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1051-00_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

130

Page 131: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1051-CCOAP3800Recessed Ceiling/Wall AP Mount - Cisco 3800 APs

Category: Wall and Hard Ceiling - Recess Mount

Locking hard lid ceiling or wall mount enclosure is designed for wireless APs andDAS remote units with detachable antennas. This aesthetic, white powder-coatedsteel enclosure has an 17.5" square bezel which fastens into the wall andsimplifies access point moves, adds, and changes. The 1051-00 model hasopenings in the door to mount up to seven external antennas. Interchangeableretrofit doors allow current owners to upgrade to new AP or antenna solutionsfrom different vendors by swapping doors.

Features & Benefits

Recessed, hard lid ceiling or wall enclosure for securing wireless access points and DAS remotes with detachable antennasUniversal T-bar mounting bracket allows easy installation of most vendors' APsFully-hinged locking door, keyed alikeInterchangeable doors permit simple migration to new APs and antennasEnclosure back-box is effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: 4.5 inch deep AP enclosure designed for recess installation in hard-lid ceilings (drywall, plaster and lath, stucco, block,core plank, etc.). Internal T-bar accommodates APs from most manufacturersThis is a steel enclosure so antennas MUST be mounted externally on the door, or AP mounted in the door. Designed for Cisco2800 and 3800 series APsPerformance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved, OPM-0110-13.De-rate AP operating temperature range by 6°C when mounted in enclosureEnclosure must be fastened to ceiling using suitable hardwareFully hinged locking door, keyed alike. Doors are interchangeableConstruction: 16 ga. back-box, 14 ga. door, textured white powder-coated steelSize: Flange is 17.5 inches by 17.5 inches (445 mm by 445 mm), enclosure is 12.5 inches by 12.5 inches by 4.5 inches deep (318mm by 318 mm by 114 mm), 4 inches (101 mm) useful depth with universal T-bar bracket in placeMaximum weight to be installed inside enclosure is 25 lbs

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUL Listed and designed to meet National Electric Code Paragraphs 300-22 and 300-23 for installation in the above-ceiling spaceUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

131

Page 132: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 17.5 in.• Width: 17.5 in.• Depth: 4.5 in.• Item Weight: 16 lbs.• Shipping Weight: 17 lbs.

Includes(1) Unit per carton(1) Internal universal AP mounting T-bar bracket(4) Hanger wires(1) Cable egress firestop Kit (1" trade size conduit connector, and firestop grommet)(2) Keys for lock(4) White cosmetic screw caps and (4) #10 ceiling/wall attachment screwsInstallation instructions

Available Accessories34-BMANT24 - 2.4 GHz Single Band WiFi Antenna: NEMA4 Enclosures34-BMANT5 - 5 GHz Single Band WiFi Antenna: NEMA4 Enclosures34-ZDUAL - Dual Band WiFi Antennas: Oberon Enclosures, RPTNC

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=3192&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1051-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1051-00_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

132

Page 133: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1051-DOMERecessed Ceiling/Wall AP Mount- ABS dome

Category: Wall and Hard Ceiling - Recess Mount

Features & Benefits

Recessed, hard lid ceiling or wall enclosure for securing wireless access points and DAS remotes with detachable antennasUniversal T-bar mounting bracket allows easy installation of most vendors' APsFully-hinged locking door, keyed alikeInterchangeable doors permit simple migration to new APs and antennasEnclosure back-box is effective dust barrier to simplify ICRA procedure compliance

Technical SpecificationsDesign: 4.5 inch deep AP enclosure designed for recess installation in hard-lid ceilings (drywall, plaster and lath, stucco, block,core plank, etc.). Internal T-bar accommodates APs from most manufacturersThis is a steel enclosure so antennas MUST be mounted externally on the door, or AP mounted in the door. Mount up to (7)external antennas on the door using the bulkhead connector kit for dipole antennas (Oberon P/N 35-BULKHD-KIT) or Oberon 34-ZDUAL or 34-DMDUAL antennasPerformance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved, OPM-0110-13.De-rate AP operating temperature range by 6°C when mounted in enclosureEnclosure must be fastened to ceiling using suitable hardwareFully hinged locking door, keyed alike. Doors are interchangeableConstruction: 16 ga. back-box, 14 ga. door, textured white powder-coated steelSize: Flange is 17.5 inches by 17.5 inches (445 mm by 445 mm), enclosure is 12.5 inches by 12.5 inches by 4.5 inches deep (318mm by 318 mm by 114 mm), 4 inches (101 mm) useful depth with universal T-bar bracket in placeMaximum weight to be installed inside enclosure is 25 lbs

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUL Listed and designed to meet National Electric Code Paragraphs 300-22 and 300-23 for installation in the above-ceiling spaceUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

133

Page 134: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 17.5 in.• Width: 17.5 in.• Depth: 4.5 in.• Item Weight: 16 lbs.• Shipping Weight: 17 lbs.

Includes(1) Unit per carton(1) Internal universal AP mounting T-bar bracket(4) Hanger wires(1) Cable egress firestop Kit (1" trade size conduit connector, and firestop grommet)(2) Keys for lock(4) White cosmetic screw caps and (4) #10 ceiling/wall attachment screwsInstallation instructions

Available Accessories34-BMANT24 - 2.4 GHz Single Band WiFi Antenna: NEMA4 Enclosures34-BMANT5 - 5 GHz Single Band WiFi Antenna: NEMA4 Enclosures34-ZDUAL - Dual Band WiFi Antennas: Oberon Enclosures, RPTNC

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=3250&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1051-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1051-00_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

134

Page 135: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1051-XXX-CCEARecessed Ceiling/Wall AP Mount

Category: Wall and Hard Ceiling - Recess Mount

Locking hard lid ceiling or wall mount enclosure is designed for wireless APs andDAS remote units with detachable antennas. This aesthetic, white powder-coatedsteel enclosure has an 17.5" square bezel which fastens into the wall andsimplifies access point moves, adds, and changes. The 1051-00 model hasopenings in the door to mount up to seven external antennas. Interchangeableretrofit doors allow current owners to upgrade to new AP or antenna solutionsfrom different vendors by swapping doors.

The –CCEA in the model number indicates that this enclosure has been speciallysealed to comply with City of Chicago Environmental Air (CCEA) standards, forplenum installation.

Features & Benefits

Recessed, hard lid ceiling or wall enclosure for securing wireless access points and DAS remotes with detachable antennasUniversal T-bar mounting bracket allows easy installation of most vendors' APsFully-hinged locking door, keyed alikeInterchangeable doors permit simple migration to new APs and antennasEnclosure back-box is effective dust barrier to simplify ICRA procedure complianceThis enclosure has been specially sealed to comply with City of Chicago Environmental Air (CCEA) standards

Technical SpecificationsDesign: 4.5 inch deep AP enclosure designed for recess installation in hard-lid ceilings (drywall, plaster and lath, stucco, block,core plank, etc.). Internal T-bar accommodates APs from most manufacturersThis is a steel enclosure so antennas MUST be mounted externally on the door, or AP mounted in the door. Mount up to (7)external antennas on the door using the bulkhead connector kit for dipole antennas (Oberon P/N 35-BULKHD-KIT) or Oberon 34-ZDUAL or 34-DMDUAL antennasPerformance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved, OPM-0110-13.De-rate AP operating temperature range by 6°C when mounted in enclosureEnclosure must be fastened to ceiling using suitable hardwareFully hinged locking door, keyed alike. Doors are interchangeableConstruction: 16 ga. back-box, 14 ga. door, textured white powder-coated steelCCEA designation indicates this product complies with City of Chicago Environmental Air requirements for installation in theplenum space. Back box has been sealed with 3M Fire Barrier Silicone Sealant 2000+Size: Flange is 17.5 inches by 17.5 inches (445 mm by 445 mm), enclosure is 12.5 inches by 12.5 inches by 4.5 inches deep (318mm by 318 mm by 114 mm), 4 inches (101 mm) useful depth with universal T-bar bracket in placeMaximum weight to be installed inside enclosure is 25 lbs

135

Page 136: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUL Listed and designed to meet National Electric Code Paragraphs 300-22 and 300-23 for installation in the above-ceiling spaceUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General RequirementsOSHPD Approval OPM-110-13

Measurements (Maximum values):

• Height: 17.5 in.• Width: 17.5 in.• Depth: 4.5 in.• Item Weight: 16 lbs.• Shipping Weight: 17 lbs.

Includes(1) Unit per carton(1) Internal universal AP mounting T-bar bracket(4) Hanger wires(1) Cable egress firestop Kit (1" trade size conduit connector, and firestop grommet)(2) Keys for lock(4) White cosmetic screw caps and (4) #10 ceiling/wall attachment screwsInstallation instructions

Available Accessories34-BMANT24 - 2.4 GHz Single Band WiFi Antenna: NEMA4 Enclosures34-BMANT5 - 5 GHz Single Band WiFi Antenna: NEMA4 Enclosures34-ZDUAL - Dual Band WiFi Antennas: Oberon Enclosures, RPTNC

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=3198&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1051-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1051-00_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

136

Page 137: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1065-CCOAPHard Ceiling Locking Mount-Cisco APs

Category: Wall and Hard Ceiling - Recess Mount

This locking recessed hard lid or wall mount is designed to provide a convenientway to secure Cisco APs in the ceiling or wall. Features a unique, patentedlocking mechanism which draws the AP part way into the mount, exposing onlythe antenna face of the AP, for the ultimate in wireless coverage, aesthetics, andphysical security. Includes recessed retaining bracket to capture mount andsimplify installation in ceilings. Textured, white powder-coated steel andaluminum construction.

Features & Benefits

Economical 18.5" x 18.5" suspended ceiling mount offers aesthetic, secure mounting of the Cisco1040/1140/1260/1600/2600/2700/3500/3600 series access pointsEnclosure back-box is effective dust barrier to simplify ICRA procedure complianceShallow back-box (2") simplifies installation in walls and ceilings

Technical SpecificationsDesign: Two piece AP locking mount designed for recess installation in hard-lid ceilings (drywall, plaster and lath, stucco, block,core plank, etc.)Performance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. OSHPD approved, OPM-0110-13Designed for Cisco 2600, 2700, 3500, 3600, 3700 series APs. Use Cisco AIR-AP-BRACKET-2 for installation. Some thinner APs mayrequire Oberon P/N 39-STANDOFF spacers to fit properly. Please contact you Oberon representativeNot designed for Cisco 2800/3800 series APsRequries only 2" mounting depth in ceilingThe 1065 is a two part assembly. 1) The Retaining Bracket must be fastened to ceiling using suitable hardware. 2) The AP mountand bezel attaches to Retaining Bracket with captured hardwareConstruction: 18 ga. white powder coated steel bezel, galvanized steel retaining bracketSize: Bezel is 18.5 inches by 18.5 inches by 2 inches deep (457mm by 457 mm by 51mm). Requires a 12 inch by 16.5 inch by 2inch (305mm by 419mm by 51mm deep) cutout in ceiling for retaining bracket

Measurements (Maximum values):

• Height: 18.5 in• Width: 18.5 in• Depth: 3 in.• Item Weight: 7 lbs.• Shipping Weight: 8 lbs.

Includes(1) Unit per carton(1) Cable egress fire stop kit (1/3" trade size conduit connector, and firestop grommet insert)(1) Enclosure mounting bracket(2) Key for lockInstallation instructionsShipping Weight: 24 lbs. with 2 units per carton, 13 lbs. with 1 unit per carton 137

Page 138: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1307&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1065-CCOAP_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1065-CCOAP_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

138

Page 139: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1076-CCOAP3" deep Recessed AP Wall Mount-Cisco AP

Category: Wall and Hard Ceiling - Recess Mount

This locking enclosure provides a convenient way to mount and secure APs fromleading vendors in the hard lid ceiling or wall. The access point mounts in thedoor, revealing only the antenna surface. Interchangeable retrofit doors permitvendor and technology migrations, and simplify moves, adds, and changes,Unique wall bridge simplifies installation. UL listed for installation in the plenumspace. 15” square white steel bezel and door.

Features & Benefits

Locking recessed wall or hard ceiling mounting solution to secure wireless access points from most vendorsUL Listed and designed to meet NEC300-22 and 300-23 for plenum installations; approved for AC line powerFully-hinged locking door, keyed alikeInterchangeable doors permit simple migration to new access points and antennasShallow back-box (3”) simplifies installation in walls and ceilingsEnclosure back-box is effective dust barrier to simplify ICRA compliance in hospitalsOSHPD approved

Technical SpecificationsDesign: Recessed hard lid ceiling or wall enclosure designed for wireless access points and wireless multimedia gateways.Designed for Cisco APs.Performance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations.Locking, fully-hinged interchangeable door for migration to other access pointsInclude firestop foam kit for cable egress1" trade size knockout on two walls; junction box knockout in back-boxConstruction: 16 ga. galvanized steel back-box; 14 ga. door; textured, white, powder-coated steel door and flange; back-box iseffective as a dust barrier for ICRA procedure complianceMaximum weight inside enclosure is 25 lbs.AP max. operating temperature should be de-rated by 10° C inside the enclosureSize: Flange is 15 inches by 15 inches (381 mm by 381 mm); enclosure back-box is 12.75 inches by 12.75 inches by 3.0 inchesdeep (324 mm by 324 mm by 77 mm deep)

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General Requirements

Measurements (Maximum values):

• Height: 15 in.• Width: 15 in.• Depth: 3 in.• Item Weight: 13 lbs.• Shipping Weight: 14 lbs.

139

Page 140: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(2) Wall bridgesUniversal access point "T-bar" mounting bracket(4) No. 8-32 hex nuts(2) Keys for lock(1) Fireblock cable egress kitInstallation Instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1271&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1076-CCOAP_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1076-CCOAP_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

140

Page 141: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1076-CP3" deep Recessed AP Wall Mount-Clear dome

Category: Wall and Hard Ceiling - Recess Mount

This locking enclosure provides a convenient way to mount and secure APs fromleading vendors in the hard lid ceiling or wall. The access point mounts in thedoor, revealing only the antenna surface. Interchangeable retrofit doors permitvendor and technology migrations, and simplify moves, adds, and changes,Unique wall bridge simplifies installation. UL listed for installation in the plenumspace. 15” square white steel bezel and door.

Features & Benefits

Locking recessed wall or hard ceiling mounting solution to secure wireless access points from most vendorsUL Listed and designed to meet NEC300-22 and 300-23 for plenum installations; approved for AC line powerFully-hinged locking door, keyed alikeInterchangeable doors permit simple migration to new access points and antennasShallow back-box (3”) simplifies installation in walls and ceilingsEnclosure back-box is effective dust barrier to simplify ICRA compliance in hospitalsOSHPD approved

Technical SpecificationsDesign: Recessed hard lid ceiling or wall enclosure designed for wireless access points and wireless multimedia gateways. Clearpolycarbonate dome in door.Performance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. Clear polycarbonate dome istransparent to wireless signal.Locking, fully-hinged interchangeable door for migration to other access pointsInclude firestop foam kit for cable egress1" trade size knockout on two walls. Junction box knockout in back-boxConstruction: 16 ga. galvanized steel back-box; 14 ga. door; textured, white, powder-coated steel door and flange; back-box iseffective as a dust barrier for ICRA procedure compliance. UL94-5VA Clear polycarbonate dome in doorMaximum weight inside enclosure is 25 lbs.AP max. operating temperature should be de-rated by 10° C inside the enclosureSize: Flange is 15 inches by 15 inches (381 mm by 381 mm), enclosure back-box is 12.75 inches by 12.75 inches by 3.0 inchesdeep (324 mm by 324 mm by 77 mm deep)

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General Requirements

141

Page 142: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 15 in.• Width: 15 in.• Depth: 3 in.• Item Weight: 13 lbs.• Shipping Weight: 14 lbs.

Includes(2) Wall bridgesUniversal access point "T-bar" mounting bracket(4) No. 8-32 hex nuts(2) Keys for lock(1) Fireblock cable egress kitInstallation Instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1269&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1076-CP_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1076-CP_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Application_Note_Wireless_Coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

142

Page 143: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1076-WA3" deep Recessed AP Wall Mount-White ABS dome

Category: Wall and Hard Ceiling - Recess Mount

This locking enclosure provides a convenient way to mount and secure APs fromleading vendors in the hard lid ceiling or wall. The access point mounts in thedoor, revealing only the antenna surface. Interchangeable retrofit doors permitvendor and technology migrations, and simplify moves, adds, and changes,Unique wall bridge simplifies installation. UL listed for installation in the plenumspace. 15” square white steel bezel and door.

Features & Benefits

Locking recessed wall or hard ceiling mounting solution to secure wireless access points from most vendorsUL Listed and designed to meet NEC300-22 and 300-23 for plenum installations; approved for AC line powerFully-hinged locking door, keyed alikeInterchangeable doors permit simple migration to new access points and antennasShallow back-box (3”) simplifies installation in walls and ceilingsEnclosure back-box is effective dust barrier to simplify ICRA compliance in hospitalsOSHPD approved

Technical SpecificationsDesign: Recessed hard lid ceiling or wall enclosure designed for wireless access points and wireless multimedia gateways. WhiteABS plastic dome in door.Performance: UL Listed and designed to meet NEC300-22 and 300-23 for plenum installations. White ABS plastic dome istransparent to wireless signal.Locking, fully-hinged interchangeable door for migration to other access pointsInclude firestop foam kit for cable egress1" trade size knockout on two walls. Junction box knockout in back-boxConstruction: 16 ga. galvanized steel back-box; 14 ga. door; textured, white, powder-coated steel door and flange; back-box iseffective as a dust barrier for ICRA procedure compliance; UL94-5VA white ABS plastic dome in doorMaximum weight inside enclosure is 25 lbs.AP max. operating temperature should be de-rated by 10° C inside the enclosureSize: Flange is 15 inches by 15 inches (381 mm by 381 mm), enclosure back-box is 12.75 inches by 12.75 inches by 3.0 inchesdeep (324 mm by 324 mm by 77 mm deep)

Standards for SafetyUL 50 listed, TYPE 1, for indoor use onlyUSL - Investigated using requirements contained in Standard UL 50 - Twelfth Edition, and UL 50E - First EditionCNL - Investigated using requirements contained in Canadian Standard CSA/C22.2 No. 94.1 and 94.2UL 2416, Audio/Video, Information and Communication Technology Equipment Cabinet, Enclosure & Rack SystemsCSA C22.2 NO. 60950-1-07 + Amd. 1 Amd. 2 Information Technology Equipment -- Safety. Part 1, General Requirements

143

Page 144: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 15 in.• Width: 15 in.• Depth: 3 in.• Item Weight: 13 lbs.• Shipping Weight: 14 lbs.

Includes(2) Wall bridgesUniversal access point "T-bar" mounting bracket(4) No. 8-32 hex nuts(2) Keys for lock(1) Fireblock cable egress kitInstallation Instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1270&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1076-WA_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1076-WA_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Application_Note_Wireless_Coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

144

Page 145: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1020-00Polycarbonate NEMA 4 AP Enclosure:Screw-on cover

Category: Indoor/Outdoor NEMA

This compact NEMA 4 enclosure is designed specifically to protect APs inchallenging environments such as stadiums and auditoriums. This ruggedpolycarbonate enclosure protects the AP from weather, pressure spray, spillingliquids, dust, and impacts, and is transparent to wireless signals so APs withbody integrated antennas or small detachable antennas may be protected.Paintable. This is the smallest NEMA 4 enclosure for most APs and is ideal forunder-seating installation.

Features & Benefits

Compact, rugged enclosure for installing access points in physically challenging environments. Ideal for under seating and riserinstallationDesigned to NEMA 1, 2, 4, 4X, 12, and 13, and IEC529-IP65 specifications for use in indoor/outdoor wet, dirty, or corrosiveenvironments. UV stabilized for exposure to direct sunlightVirtually transparent to wireless signalsPlastic is easily drilled and machined for custom cable ingress and installation. Enclosure is paintableCover attaches with four stainless steel screws, silicon sponge gasket material provides seal

Technical SpecificationsDesign: Compact, rugged polycarbonate wireless access point enclosure designed for surface mounting indoors or outdoors, andfor under seating and riser installation.Performance: Designed to NEMA 1, 2, 4, 4X, 12, and 13, and IEC529-IP66 specifications for indoor/outdoor wet, dirty, or corrosiveenvironments. UV-stabilized for exposure to direct sunlight. Transparent to wireless signals. Paintable.Oberon Skybar-shaped screw on cover with gasket; cover screws must be torqued to 8in-lbs.; cover screws are recessed intocoverInternal universal T-bar bracketConstruction: UL listed to UL508; body and cover are light gray UL94-V0 PBT/PC blended plasticAP max. operating temperature should be de-rated by 11° C inside the enclosureTemperature rating: -40 to 120° CExterior Size: 9.1 inches by 13.4 inches by 4 inches (340mm by 231mm by 102mm; interior dimensions 8.8 inches by 10.5 inchesby 3.7 inches (224 mm by 267 mm by 95 mm)

Measurements (Maximum values):

• Height: 9.1 in• Width: 13.4 in.• Depth: 4.0 in.• Item Weight: 3 lbs.• Shipping Weight: 4 lbs.

145

Page 146: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit per carton(1) T-bar bracket(2) 1/2" Nylon spacer(2) #6 x 7/8" screw(4) #6 x 1/4 screw(4) M4 x 20mm lid screwInstallation instructions

Available Accessories39-CORD-GRIP - Cord Grip Connector for Pre-Terminated Cables39-RJ45-BULKHEAD - Bulkhead Modular Pass -Through

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1291&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1020-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1020-00_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Model1025-00_coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

146

Page 147: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1020-RABNEMA 4 AP Enclosure:Screw-on cover, Right-angle

Category: Indoor/Outdoor NEMA

1020-RAB is a compact indoor/outdoor NEMA 4 enclosure that protects APs inchallenging environments, and mounts the equipment in a horizontal orientationto achieve best wireless coverage. This rugged polycarbonate enclosure protectsthe AP from weather, pressure spray, spilling liquids, dust, and impacts, and istransparent to wireless signals so APs with body-integrated antennas or smalldetachable antennas may be protected. This plastic is paintable for moreeffective concealment.

Features & Benefits

Compact, rugged enclosure for installing APs in challenging environments; right-angle bracket (RAB) included for wall mountingDesigned to NEMA 1, 2, 4, 4X, 12, and 13, and IEC529-IP65 specifications for use in indoor/outdoor wet, dirty, or corrosiveenvironments; UV stabilized for exposure to direct sunlightVirtually transparent to wireless signalsPlastic is easily drilled and machined for custom cable ingress and installation; enclosure is paintableCover attaches with four stainless steel screws; silicon gasket material provides seal

Technical SpecificationsDesign: Rugged polycarbonate NEMA wireless access point enclosure designed for surface mounting indoors or outdoors.Includes right-angle bracket for mounting enclosure in preferred horizontal orientation on wall or pole. Right-angle wall bracketacts as sun shield for enclosure. Helps to reduce solar load on outdoor mounted enclosure.Performance: Designed to NEMA 1, 2, 4, 4X, 12, and 13, and IEC529-IP66 specifications for indoor/outdoor wet, dirty, or corrosiveenvironments. UV-stabilized for exposure to direct sunlight. Transparent to wireless signals. Paintable.Exterior 10ga steel right-angle mounting bracket; grey powder-coatedOberon Skybar-shaped screw on cover with gasket; cover screws must be torqued to 8in-lbs.; cover screws are recessed intocoverInternal universal T-bar bracketConstruction: UL listed to UL508; body and cover are light gray UL94-V0 PBT/PC blended plasticAP max. operating temperature should be de-rated by 11° C inside the enclosureTemperature rating: -40 to 120° CExterior Size: 10.78 inches by 9.06 inches by 7.39 inches (274mm by 230mm by 188mm Interior dimensions 8.8 inches by 10.5inches by 3.7 inches (224 mm by 267 mm by 95 mm)

Measurements (Maximum values):

• Height: 10.78 in.• Width: 9.06 in.• Depth: 7.39 in.• Item Weight: 5 lbs.• Shipping Weight: 6 lbs.

147

Page 148: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Oberon Model 1020-00 Base and Lid(1) Universal T-bar bracket(2) Nylon Spacer(1) Right-angle enclosure bracket(2) #6 x 7/8" Screw(4) #6 x 1/4" Screw(4) M4 x 20mm Lid Screw(4) M4 x 10mm Bracket Screw(4) 4mm Lock Washer(4) 10mm Hex StandoffInstallation instructions

Available Accessories39-1020-PMK - Pole Mount Kit for Oberon Model 1020-RAB39-CORD-GRIP - Cord Grip Connector for Pre-Terminated Cables39-RJ45-BULKHEAD - Bulkhead Modular Pass -Through

Videos - https://www.youtube.com/user/oberoninc1020-RAB - Cisco APs - Installation Video View at https://youtu.be/_XVPcoB83V0

1020-RAB - Aruba APs - Installation Video View at https://youtu.be/kbHR34QuVvY

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1517&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1020-RAB_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1020-RAB_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Model1025-00_coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

148

Page 149: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1020-RAB-PMKNEMA 4 AP Enclosure:Screw-on cover, Right-angle

Category: Indoor/Outdoor NEMA

Features & Benefits

Compact, rugged enclosure for installing APs in challenging environments; right-angle bracket (RAB) and pole mount kit (PMK)included for wall mounting or pole mountingDesigned to NEMA 1, 2, 4, 4X, 12, and 13, and IEC529-IP65 specifications for use in indoor/outdoor wet, dirty, or corrosiveenvironments; UV stabilized for exposure to direct sunlightVirtually transparent to wireless signalsPlastic is easily drilled and machined for custom cable ingress and installation; enclosure is paintableCover attaches with four stainless steel screws; silicon gasket material provides sealAdjustable worm gear clamps for square and round poles with diameters from 4" to 7"

Measurements (Maximum values):

• Height: 9.06 in.• Width: 12.77 in.• Depth: 6.20 in.• Item Weight: 10 lbs.• Shipping Weight: 11 lbs.

IncludesUL94-V0 Gray Polycarbonate NEMA 4 EnclosureGray Powdercoated Right Angle BracketPole Mount BracketT-Bar Bracket(4) M4x0.7 x 10mm Screws(4) M4x0.7 x 20mm Screws(4) #6-32 x 1/4 Screws(2) #6-32 x 7/8 Screws(4) #10-32 x 3/8 Screws(2) Nylon Spacer(2) Worm Drive Clamp 5-5/8" to 8-1/2" ID(4) Stainless Steel #10 ScrewsInstallation Instructions

Available Accessories39-1020-PMK - Pole Mount Kit for Oberon Model 1020-RAB39-CORD-GRIP - Cord Grip Connector for Pre-Terminated Cables39-RJ45-BULKHEAD - Bulkhead Modular Pass -Through

149

Page 150: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=3086&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1020-RAB-PMK_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1020-RAB-PMK_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Model1025-00_coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

150

Page 151: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1024-00Polycarbonate NEMA 4 AP Enclosure-Solid door

Category: Indoor/Outdoor NEMA

This compact NEMA 4X enclosure is designed to protect wireless LAN APs withinternal or external antennas in challenging indoor/outdoor environments. Thisrugged polycarbonate enclosure protects the AP from weather, dust, andimpacts, and is transparent to wireless signals so APs with body integratedantennas or small detachable antennas may be protected. The enclosure has ahinged door, molded-in padlock hasps for locking, and interior panel forattaching APs. Enclosure is paintable.

Features & Benefits

Designed for protecting leading vendors' enterprise wireless access points and DAS remotes, inside and outsideHinged cover, latchable, lockable

Technical SpecificationsDesign: Polycarbonate NEMA wireless access point enclosure designed for wall or mast mounting indoors or outdoors, wheresecure mounting is required. Large enough for access points with external dipole antennas. Hinged, lockable door.Performance: Designed to NEMA 1, 2, 4, 4X, 12, and 13, and IEC529-IP66 specifications for indoor/outdoor wet, dirty, or corrosiveenvironments. UV-stabilized for exposure to direct sunlight. Transparent to wireless signals. Paintable.Hinged, gasketed door with hasps for padlockInternal plastic universal mounting panelConstruction: UL listed to UL508; back-box and cover are light gray UL94-5VA PBT/PC blended plasticAP max. operating temperature should be de-rated by 9° C inside the enclosureTemperature rating: -40 to 70° CExterior size: 15.7 inches by 11.7 inches by 4.8inches (400mm by 297mm by 122mm; interior dimensions: 14.9 inches by 10.9inches by 4.5 inches (376 mm by 274 mm by 114 mm)

Measurements (Maximum values):

• Height: 15.7 in.• Width: 11.7 in.• Depth: 4.8 in.• Item Weight: 6.3 lbs.• Shipping Weight: 8 lbs.

151

Page 152: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(4) Stainless steel wall mounting brackets(2) 1/2" O.D. Nylon spacer(1) T-Bar bracket(2) #6 x 7/8" screw(4) #8 x 3/8" screw(4) M5 x 10mm screw(1) Interior mounting panel for most vendors' access pointsInstallation instructions

Available Accessories39-POLE-MOUNT-BRACKET - Model 1020, Model 1024: Pole Mount Kit

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1280&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1024-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1024-00_Customer_Print.pdf

Weatherproofing Instructions - oberoninc.com/images/WebDocs/Model1024-00_Assembly_w_Cisco_AP.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Model1025-00_coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

152

Page 153: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1024-CPolycarbonate NEMA 4 AP Enclosure-Clear door

Category: Indoor/Outdoor NEMA

This compact NEMA 4X enclosure is designed to protect wireless LAN APs withinternal or external antennas in challenging indoor/outdoor environments. Thisrugged polycarbonate enclosure protects the AP from weather, dust, andimpacts, and is transparent to wireless signals so APs with body integratedantennas or small detachable antennas may be protected. The enclosure has ahinged door, molded-in padlock hasps for locking, and interior panel forattaching APs. Enclosure is paintable.

Features & Benefits

Designed for protecting leading vendors' enterprise wireless access points and DAS remotes, inside and outsideHinged cover, latchable, lockable

Technical SpecificationsDesign: PBT/Polycarbonate blended NEMA wireless access point enclosure designed for wall or mast mounting indoors oroutdoors, where secure mounting is required. Large enough for access points with external dipole antennas. Clear, hinged,lockable door.Performance: Designed to NEMA 1, 2, 4, 4X, 12, and 13, and IEC529-IP66 specifications for indoor/outdoor wet, dirty, or corrosiveenvironments. UV-stabilized for exposure to direct sunlight. Transparent to wireless signals. PaintableClear, hinged, gasketed door with hasps for padlockInternal plastic universal mounting panelConstruction: UL listed to UL508; back-box is light gray UL94-5VA PBT/PC blended plastic; door is UL94-V0 clear polycarbonateAP max. operating temperature should be de-rated by 9° C inside the enclosureTemperature rating: -40 to 70° CExterior size: 15.7 inches by 11.7 inches by 4.8inches (400mm by 297mm by 122mm; interior dimensions: 14.9 inches by 10.9inches by 4.5 inches (376 mm by 274 mm by 114 mm)

Measurements (Maximum values):

• Height: 15.7 in.• Width: 11.7 in.• Depth: 4.8 in.• Item Weight: 6.3 lbs.• Shipping Weight: 8 lbs.

153

Page 154: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(4) Stainless steel wall mounting brackets(2) 1/2" O.D. Nylon spacer(1) T-Bar bracket(2) #6 x 7/8" screw(4) #8 x 3/8" screw(4) M5 x 10mm screw(1) Interior mounting panel for most vendors' access pointsInstallation instructions

Available Accessories39-POLE-MOUNT-BRACKET - Model 1020, Model 1024: Pole Mount Kit

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2096&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1024-C_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1024-C_Customer_Print.pdf

Weatherproofing Instructions - oberoninc.com/images/WebDocs/Model1024-00_Assembly_w_Cisco_AP.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Model1025-00_coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

154

Page 155: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1026-00Polycarbonate NEMA4 WiFi AP Box-12x10x6 solid door

Category: Indoor/Outdoor NEMA

NEMA 4X enclosure protects APs with internal or external antennas from allvendors in challenging indoor/outdoor environments. This rugged polycarbonateenclosure protects the AP from weather, dust, and impacts, and is transparent towireless signals so APs with body integrated antennas or small detachableantennas may be protected. The enclosure has a hinged door, molded-in padlockhasps for locking, and interior ABS panel for attaching APs. Paintable. Convenientsizes are available.

Features & Benefits

Compact, low-profile wireless access point enclosure for indoor and outdoor applications such as stadiums and public hotspotsUV-stabilized for exposure to direct sunlightVirtually transparent to wireless signalsUniversal mounting plate allows easy installation of most vendors’ APsCover is hinged; cover can be latched and locked with padlock (not included)Tinted clear polycarbonate cover is available upon request; please specify as “-C” in model number

Technical SpecificationsDesign: Polycarbonate NEMA wireless access point enclosure designed for wall or mast mounting indoors or outdoors, wheresecure mounting is required. Large enough for Cisco 3500/3600 wireless access points. Fully-hinged, lockable door.Performance: Designed to NEMA 3R, 4, 4X, 12, and 6P, and IEC529-IP68 specifications for indoor/outdoor wet, dirty, or corrosiveenvironments. UV-stabilized for exposure to direct sunlight. Transparent to wireless signals. Paintable.AP max. operating temperature should be de-rated by 9 °CTemperature rating: -30 to 115° CFully-hinged, gasketed door with hasps for padlockInternal plastic universal mounting panelConstruction: UL listed to UL50 and UL508A; back-box and cover are light gray UL94-5VA polycarbonate plasticSize: 11.6 inches by 13.4 inches by 7.6 inches (295 mm by 340 mm by 193 mm)

Standards for SafetyDesigned to NEMA 3R, 4, 4X, 12, and 6P, and IEC529-IP68 specifications for indoor/ outdoor wet, dirty, or corrosive environmentsUL508 listed; back-box and cover are light gray UL94-5VA Polycarbonate; tinted clear cover is UL94V-0 Polycarbonate

Measurements (Maximum values):

• Height: 11.6 in.• Width: 13.4 in.• Depth: 7.6 in.• Item Weight: 7 lbs.• Shipping Weight: 7 lbs.

155

Page 156: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(4) #8 - 32 screw(4) Mounting feet(4) #10 - 32 mounting feet screwInstallation instructions

Available AccessoriesAccessories

39-POLE-MOUNT-BRACKET - Model 1020, Model 1024: Pole Mount Kit39-RJ45-BULKHEAD - Bulkhead Modular Pass -Through

Cables for Oberon Antennas & Enclosures

39-BULKHD-KIT-RPTNC(F) - Pigtail Cable for Antennas on Enclosure Door - RPTNC39-BULKHD-KIT-RPSMA - Pigtail Cable for Antennas on Enclosure Door - RPSM39-CORD-GRIP - Cable ingress/egress fitting

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1281&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1026-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1026-00_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Model1025-00_coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

156

Page 157: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1026-864Polycarbonate NEMA4 WiFi AP Box-8x6x4 solid door

Category: Indoor/Outdoor NEMA

NEMA 4X enclosure protects APs with internal or external antennas from allvendors in challenging indoor/outdoor environments. This rugged polycarbonateenclosure protects the AP from weather, dust, and impacts, and is transparent towireless signals so APs with body integrated antennas or small detachableantennas may be protected. The enclosure has a hinged door, molded-in padlockhasps for locking, and interior ABS panel for attaching APs. Paintable. Convenientsizes are available.

Features & Benefits

Compact, low-profile wireless access point enclosure for indoor and outdoor applications such as stadiums and public hotspotsUV-stabilized for exposure to direct sunlightVirtually transparent to wireless signalsUniversal mounting plate allows easy installation of most vendors’ APsCover is hinged; cover can be latched and locked with padlock (not included)Tinted clear polycarbonate cover is available upon request; please specify as “-C” in model number

Technical SpecificationsInterior Dimensions: various sizes available, please see Configurations or contact your Oberon representativeAP max. operating temperature should be de-rated by 9 °CTemperature rating: -30 to 115° C

Standards for SafetyDesigned to NEMA 3R, 4, 4X, 12, and 6P, and IEC529-IP68 specifications for indoor/ outdoor wet, dirty, or corrosive environmentsUL508 listed; back-box and cover are light gray UL94-5VA Polycarbonate; tinted clear cover is UL94V-0 Polycarbonate

Measurements (Maximum values):

• Height: 24 in.• Width: 24 in.• Depth: 10 in.• Item Weight: 7 lbs.• Shipping Weight: 7 lbs.

157

Page 158: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(4) #8 - 32 screw(4) Mounting feet(4) #10 - 32 mounting feet screwInstallation instructions

Available AccessoriesAccessories

39-POLE-MOUNT-BRACKET - Model 1020, Model 1024: Pole Mount Kit39-RJ45-BULKHEAD - Bulkhead Modular Pass -Through

Cables for Oberon Antennas & Enclosures

39-BULKHD-KIT-RPTNC(F) - Pigtail Cable for Antennas on Enclosure Door - RPTNC39-BULKHD-KIT-RPSMA - Pigtail Cable for Antennas on Enclosure Door - RPSM39-CORD-GRIP - Cable ingress/egress fitting

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2030&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1026-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1026-00_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Model1025-00_coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

158

Page 159: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1026-864-CPolycarbonate NEMA4 WiFi AP Box-8x6x4 clear door

Category: Indoor/Outdoor NEMA

NEMA 4X enclosure protects APs with internal or external antennas from allvendors in challenging indoor/outdoor environments. This rugged polycarbonateenclosure protects the AP from weather, dust, and impacts, and is transparent towireless signals so APs with body integrated antennas or small detachableantennas may be protected. The enclosure has a hinged door, molded-in padlockhasps for locking, and interior ABS panel for attaching APs. Paintable. Convenientsizes are available.

Features & Benefits

Compact, low-profile wireless access point enclosure for indoor and outdoor applications such as stadiums and public hotspotsUV-stabilized for exposure to direct sunlightVirtually transparent to wireless signalsUniversal mounting plate allows easy installation of most vendors’ APsCover is hinged; cover can be latched and locked with padlock (not included)Tinted clear polycarbonate cover is available upon request; please specify as “-C” in model number

Technical SpecificationsInterior Dimensions: various sizes available, please see Configurations or contact your Oberon representativeAP max. operating temperature should be de-rated by 9 °CTemperature rating: -30 to 115° C

Standards for SafetyDesigned to NEMA 3R, 4, 4X, 12, and 6P, and IEC529-IP68 specifications for indoor/ outdoor wet, dirty, or corrosive environmentsUL508 listed; back-box and cover are light gray UL94-5VA Polycarbonate; tinted clear cover is UL94V-0 Polycarbonate

Measurements (Maximum values):

• Height: 24 in.• Width: 24 in.• Depth: 10 in.• Item Weight: 7 lbs.• Shipping Weight: 7 lbs.

159

Page 160: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(4) #8 - 32 screw(4) Mounting feet(4) #10 - 32 mounting feet screwInstallation instructions

Available AccessoriesAccessories

39-POLE-MOUNT-BRACKET - Model 1020, Model 1024: Pole Mount Kit39-RJ45-BULKHEAD - Bulkhead Modular Pass -Through

Cables for Oberon Antennas & Enclosures

39-BULKHD-KIT-RPTNC(F) - Pigtail Cable for Antennas on Enclosure Door - RPTNC39-BULKHD-KIT-RPSMA - Pigtail Cable for Antennas on Enclosure Door - RPSM39-CORD-GRIP - Cable ingress/egress fitting

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2036&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1026-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1026-00_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Model1025-00_coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

160

Page 161: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1026-1084Polycarbonate NEMA4 WiFi AP Box-10x8x4 solid door

Category: Indoor/Outdoor NEMA

NEMA 4X enclosure protects APs with internal or external antennas from allvendors in challenging indoor/outdoor environments. This rugged polycarbonateenclosure protects the AP from weather, dust, and impacts, and is transparent towireless signals so APs with body integrated antennas or small detachableantennas may be protected. The enclosure has a hinged door, molded-in padlockhasps for locking, and interior ABS panel for attaching APs. Paintable. Convenientsizes are available.

Features & Benefits

Compact, low-profile wireless access point enclosure for indoor and outdoor applications such as stadiums and public hotspotsUV-stabilized for exposure to direct sunlightVirtually transparent to wireless signalsUniversal mounting plate allows easy installation of most vendors’ APsCover is hinged; cover can be latched and locked with padlock (not included)Tinted clear polycarbonate cover is available upon request; please specify as “-C” in model number

Technical SpecificationsInterior Dimensions: various sizes available, please see Configurations or contact your Oberon representativeAP max. operating temperature should be de-rated by 9 °CTemperature rating: -30 to 115° C

Standards for SafetyDesigned to NEMA 3R, 4, 4X, 12, and 6P, and IEC529-IP68 specifications for indoor/ outdoor wet, dirty, or corrosive environmentsUL508 listed; back-box and cover are light gray UL94-5VA Polycarbonate; tinted clear cover is UL94V-0 Polycarbonate

Measurements (Maximum values):

• Height: 10 in.• Width: 8 in.• Depth: 4 in.• Item Weight: 7 lbs.• Shipping Weight: 7 lbs.

161

Page 162: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(4) #8 - 32 screw(4) Mounting feet(4) #10 - 32 mounting feet screwInstallation instructions

Available AccessoriesAccessories

39-POLE-MOUNT-BRACKET - Model 1020, Model 1024: Pole Mount Kit39-RJ45-BULKHEAD - Bulkhead Modular Pass -Through

Cables for Oberon Antennas & Enclosures

39-BULKHD-KIT-RPTNC(F) - Pigtail Cable for Antennas on Enclosure Door - RPTNC39-BULKHD-KIT-RPSMA - Pigtail Cable for Antennas on Enclosure Door - RPSM39-CORD-GRIP - Cable ingress/egress fitting

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2042&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1026-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1026-00_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Model1025-00_coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

162

Page 163: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1026-1084-CPolycarbonate NEMA4 WiFi AP Box-10x8x4 clear door

Category: Indoor/Outdoor NEMA

NEMA 4X enclosure protects APs with internal or external antennas from allvendors in challenging indoor/outdoor environments. This rugged polycarbonateenclosure protects the AP from weather, dust, and impacts, and is transparent towireless signals so APs with body integrated antennas or small detachableantennas may be protected. The enclosure has a hinged door, molded-in padlockhasps for locking, and interior ABS panel for attaching APs. Paintable. Convenientsizes are available.

Features & Benefits

Compact, low-profile wireless access point enclosure for indoor and outdoor applications such as stadiums and public hotspotsUV-stabilized for exposure to direct sunlightVirtually transparent to wireless signalsUniversal mounting plate allows easy installation of most vendors’ APsCover is hinged; cover can be latched and locked with padlock (not included)Tinted clear polycarbonate cover is available upon request; please specify as “-C” in model number

Technical SpecificationsInterior Dimensions: various sizes available, please see Configurations or contact your Oberon representativeAP max. operating temperature should be de-rated by 9 °CTemperature rating: -30 to 115° C

Standards for SafetyDesigned to NEMA 3R, 4, 4X, 12, and 6P, and IEC529-IP68 specifications for indoor/ outdoor wet, dirty, or corrosive environmentsUL508 listed; back-box and cover are light gray UL94-5VA Polycarbonate; tinted clear cover is UL94V-0 Polycarbonate

Measurements (Maximum values):

• Height: 10 in.• Width: 8 in.• Depth: 4 in.• Item Weight: 7 lbs.• Shipping Weight: 7 lbs.

163

Page 164: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(4) #8 - 32 screw(4) Mounting feet(4) #10 - 32 mounting feet screwInstallation instructions

Available AccessoriesAccessories

39-POLE-MOUNT-BRACKET - Model 1020, Model 1024: Pole Mount Kit39-RJ45-BULKHEAD - Bulkhead Modular Pass -Through

Cables for Oberon Antennas & Enclosures

39-BULKHD-KIT-RPTNC(F) - Pigtail Cable for Antennas on Enclosure Door - RPTNC39-BULKHD-KIT-RPSMA - Pigtail Cable for Antennas on Enclosure Door - RPSM39-CORD-GRIP - Cable ingress/egress fitting

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2048&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1026-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1026-00_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Model1025-00_coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

164

Page 165: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1026-14126Polycarbonate NEMA4 WiFi AP Box-14x12x6 solid door

Category: Indoor/Outdoor NEMA

NEMA 4X enclosure protects APs with internal or external antennas from allvendors in challenging indoor/outdoor environments. This rugged polycarbonateenclosure protects the AP from weather, dust, and impacts, and is transparent towireless signals so APs with body integrated antennas or small detachableantennas may be protected. The enclosure has a hinged door, molded-in padlockhasps for locking, and interior ABS panel for attaching APs. Paintable. Convenientsizes are available.

Features & Benefits

Compact, low-profile wireless access point enclosure for indoor and outdoor applications such as stadiums and public hotspotsUV-stabilized for exposure to direct sunlightVirtually transparent to wireless signalsUniversal mounting plate allows easy installation of most vendors’ APsCover is hinged; cover can be latched and locked with padlock (not included)Tinted clear polycarbonate cover is available upon request; please specify as “-C” in model number

Technical SpecificationsInterior Dimensions: various sizes available, please see Configurations or contact your Oberon representativeAP max. operating temperature should be de-rated by 9 °CTemperature rating: -30 to 115° C

Standards for SafetyDesigned to NEMA 3R, 4, 4X, 12, and 6P, and IEC529-IP68 specifications for indoor/ outdoor wet, dirty, or corrosive environmentsUL508 listed; back-box and cover are light gray UL94-5VA Polycarbonate; tinted clear cover is UL94V-0 Polycarbonate

Measurements (Maximum values):

• Height: 14 in.• Width: 12 in.• Depth: 6 in.• Item Weight: 7 lbs.• Shipping Weight: 7 lbs.

165

Page 166: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(4) #8 - 32 screw(4) Mounting feet(4) #10 - 32 mounting feet screwInstallation instructions

Available AccessoriesAccessories

39-POLE-MOUNT-BRACKET - Model 1020, Model 1024: Pole Mount Kit39-RJ45-BULKHEAD - Bulkhead Modular Pass -Through

Cables for Oberon Antennas & Enclosures

39-BULKHD-KIT-RPTNC(F) - Pigtail Cable for Antennas on Enclosure Door - RPTNC39-BULKHD-KIT-RPSMA - Pigtail Cable for Antennas on Enclosure Door - RPSM39-CORD-GRIP - Cable ingress/egress fitting

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2060&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1026-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1026-00_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Model1025-00_coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

166

Page 167: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1026-14126-CPolycarbonate NEMA4 WiFi AP Box-14x12x6 clear door

Category: Indoor/Outdoor NEMA

NEMA 4X enclosure protects APs with internal or external antennas from allvendors in challenging indoor/outdoor environments. This rugged polycarbonateenclosure protects the AP from weather, dust, and impacts, and is transparent towireless signals so APs with body integrated antennas or small detachableantennas may be protected. The enclosure has a hinged door, molded-in padlockhasps for locking, and interior ABS panel for attaching APs. Paintable. Convenientsizes are available.

Features & Benefits

Compact, low-profile wireless access point enclosure for indoor and outdoor applications such as stadiums and public hotspotsUV-stabilized for exposure to direct sunlightVirtually transparent to wireless signalsUniversal mounting plate allows easy installation of most vendors’ APsCover is hinged; cover can be latched and locked with padlock (not included)Tinted clear polycarbonate cover is available upon request; please specify as “-C” in model number

Technical SpecificationsInterior Dimensions: various sizes available, please see Configurations or contact your Oberon representativeAP max. operating temperature should be de-rated by 9 °CTemperature rating: -30 to 115° C

Standards for SafetyDesigned to NEMA 3R, 4, 4X, 12, and 6P, and IEC529-IP68 specifications for indoor/ outdoor wet, dirty, or corrosive environmentsUL508 listed; back-box and cover are light gray UL94-5VA Polycarbonate; tinted clear cover is UL94V-0 Polycarbonate

Measurements (Maximum values):

• Height: 14 in.• Width: 12 in.• Depth: 6 in.• Item Weight: 7 lbs.• Shipping Weight: 7 lbs.

167

Page 168: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(4) #8 - 32 screw(4) Mounting feet(4) #10 - 32 mounting feet screwInstallation instructions

Available AccessoriesAccessories

39-POLE-MOUNT-BRACKET - Model 1020, Model 1024: Pole Mount Kit39-RJ45-BULKHEAD - Bulkhead Modular Pass -Through

Cables for Oberon Antennas & Enclosures

39-BULKHD-KIT-RPTNC(F) - Pigtail Cable for Antennas on Enclosure Door - RPTNC39-BULKHD-KIT-RPSMA - Pigtail Cable for Antennas on Enclosure Door - RPSM39-CORD-GRIP - Cable ingress/egress fitting

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2066&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1026-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1026-00_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Model1025-00_coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

168

Page 169: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1026-16148Polycarbonate NEMA4 WiFi AP Box-16x14x8 solid door

Category: Indoor/Outdoor NEMA

NEMA 4X enclosure protects APs with internal or external antennas from allvendors in challenging indoor/outdoor environments. This rugged polycarbonateenclosure protects the AP from weather, dust, and impacts, and is transparent towireless signals so APs with body integrated antennas or small detachableantennas may be protected. The enclosure has a hinged door, molded-in padlockhasps for locking, and interior ABS panel for attaching APs. Paintable. Convenientsizes are available.

Features & Benefits

Compact, low-profile wireless access point enclosure for indoor and outdoor applications such as stadiums and public hotspotsUV-stabilized for exposure to direct sunlightVirtually transparent to wireless signalsUniversal mounting plate allows easy installation of most vendors’ APsCover is hinged; cover can be latched and locked with padlock (not included)Tinted clear polycarbonate cover is available upon request; please specify as “-C” in model number

Technical SpecificationsInterior Dimensions: various sizes available, please see Configurations or contact your Oberon representativeAP max. operating temperature should be de-rated by 9 °CTemperature rating: -30 to 115° C

Standards for SafetyDesigned to NEMA 3R, 4, 4X, 12, and 6P, and IEC529-IP68 specifications for indoor/ outdoor wet, dirty, or corrosive environmentsUL508 listed; back-box and cover are light gray UL94-5VA Polycarbonate; tinted clear cover is UL94V-0 Polycarbonate

Measurements (Maximum values):

• Height: 16 in.• Width: 14 in.• Depth: 8 in.• Item Weight: 7 lbs.• Shipping Weight: 7 lbs.

169

Page 170: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(4) #8 - 32 screw(4) Mounting feet(4) #10 - 32 mounting feet screwInstallation instructions

Available AccessoriesAccessories

39-POLE-MOUNT-BRACKET - Model 1020, Model 1024: Pole Mount Kit39-RJ45-BULKHEAD - Bulkhead Modular Pass -Through

Cables for Oberon Antennas & Enclosures

39-BULKHD-KIT-RPTNC(F) - Pigtail Cable for Antennas on Enclosure Door - RPTNC39-BULKHD-KIT-RPSMA - Pigtail Cable for Antennas on Enclosure Door - RPSM39-CORD-GRIP - Cable ingress/egress fitting

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2072&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1026-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1026-00_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Model1025-00_coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

170

Page 171: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1026-16148-CPolycarbonate NEMA4 WiFi AP Box-16x14x8 clear door

Category: Indoor/Outdoor NEMA

NEMA 4X enclosure protects APs with internal or external antennas from allvendors in challenging indoor/outdoor environments. This rugged polycarbonateenclosure protects the AP from weather, dust, and impacts, and is transparent towireless signals so APs with body integrated antennas or small detachableantennas may be protected. The enclosure has a hinged door, molded-in padlockhasps for locking, and interior ABS panel for attaching APs. Paintable. Convenientsizes are available.

Features & Benefits

Compact, low-profile wireless access point enclosure for indoor and outdoor applications such as stadiums and public hotspotsUV-stabilized for exposure to direct sunlightVirtually transparent to wireless signalsUniversal mounting plate allows easy installation of most vendors’ APsCover is hinged; cover can be latched and locked with padlock (not included)Tinted clear polycarbonate cover is available upon request; please specify as “-C” in model number

Technical SpecificationsInterior Dimensions: various sizes available, please see Configurations or contact your Oberon representativeAP max. operating temperature should be de-rated by 9 °CTemperature rating: -30 to 115° C

Standards for SafetyDesigned to NEMA 3R, 4, 4X, 12, and 6P, and IEC529-IP68 specifications for indoor/ outdoor wet, dirty, or corrosive environmentsUL508 listed; back-box and cover are light gray UL94-5VA Polycarbonate; tinted clear cover is UL94V-0 Polycarbonate

Measurements (Maximum values):

• Height: 15 in.• Width: 14 in.• Depth: 8 in.• Item Weight: 7 lbs.• Shipping Weight: 7 lbs.

171

Page 172: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(4) #8 - 32 screw(4) Mounting feet(4) #10 - 32 mounting feet screwInstallation instructions

Available AccessoriesAccessories

39-POLE-MOUNT-BRACKET - Model 1020, Model 1024: Pole Mount Kit39-RJ45-BULKHEAD - Bulkhead Modular Pass -Through

Cables for Oberon Antennas & Enclosures

39-BULKHD-KIT-RPTNC(F) - Pigtail Cable for Antennas on Enclosure Door - RPTNC39-BULKHD-KIT-RPSMA - Pigtail Cable for Antennas on Enclosure Door - RPSM39-CORD-GRIP - Cable ingress/egress fitting

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2078&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1026-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1026-00_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Model1025-00_coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

172

Page 173: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1026-242410Polycarbonate NEMA4 WiFi AP Box-24x24x10 solid door

Category: Indoor/Outdoor NEMA

NEMA 4X enclosure protects APs with internal or external antennas from allvendors in challenging indoor/outdoor environments. This rugged polycarbonateenclosure protects the AP from weather, dust, and impacts, and is transparent towireless signals so APs with body integrated antennas or small detachableantennas may be protected. The enclosure has a hinged door, molded-in padlockhasps for locking, and interior ABS panel for attaching APs. Paintable. Convenientsizes are available.

Features & Benefits

Compact, low-profile wireless access point enclosure for indoor and outdoor applications such as stadiums and public hotspotsUV-stabilized for exposure to direct sunlightVirtually transparent to wireless signalsUniversal mounting plate allows easy installation of most vendors’ APsCover is hinged; cover can be latched and locked with padlock (not included)Tinted clear polycarbonate cover is available upon request; please specify as “-C” in model number

Technical SpecificationsInterior Dimensions: various sizes available, please see Configurations or contact your Oberon representativeAP max. operating temperature should be de-rated by 9 °CTemperature rating: -30 to 115° C

Standards for SafetyDesigned to NEMA 3R, 4, 4X, 12, and 6P, and IEC529-IP68 specifications for indoor/ outdoor wet, dirty, or corrosive environmentsUL508 listed; back-box and cover are light gray UL94-5VA Polycarbonate; tinted clear cover is UL94V-0 Polycarbonate

Measurements (Maximum values):

• Height: 24 in.• Width: 24 in.• Depth: 10 in.• Item Weight: 7 lbs.• Shipping Weight: 7 lbs.

173

Page 174: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(4) #8 - 32 screw(4) Mounting feet(4) #10 - 32 mounting feet screwInstallation instructions

Available AccessoriesAccessories

39-POLE-MOUNT-BRACKET - Model 1020, Model 1024: Pole Mount Kit39-RJ45-BULKHEAD - Bulkhead Modular Pass -Through

Cables for Oberon Antennas & Enclosures

39-BULKHD-KIT-RPTNC(F) - Pigtail Cable for Antennas on Enclosure Door - RPTNC39-BULKHD-KIT-RPSMA - Pigtail Cable for Antennas on Enclosure Door - RPSM39-CORD-GRIP - Cable ingress/egress fitting

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2084&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1026-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1026-00_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Model1025-00_coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

174

Page 175: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1026-242410-CPolycarbonate NEMA4 WiFi AP Box-24x24x10 clear door

Category: Indoor/Outdoor NEMA

NEMA 4X enclosure protects APs with internal or external antennas from allvendors in challenging indoor/outdoor environments. This rugged polycarbonateenclosure protects the AP from weather, dust, and impacts, and is transparent towireless signals so APs with body integrated antennas or small detachableantennas may be protected. The enclosure has a hinged door, molded-in padlockhasps for locking, and interior ABS panel for attaching APs. Paintable. Convenientsizes are available.

Features & Benefits

Compact, low-profile wireless access point enclosure for indoor and outdoor applications such as stadiums and public hotspotsUV-stabilized for exposure to direct sunlightVirtually transparent to wireless signalsUniversal mounting plate allows easy installation of most vendors’ APsCover is hinged; cover can be latched and locked with padlock (not included)Tinted clear polycarbonate cover is available upon request; please specify as “-C” in model number

Technical SpecificationsInterior Dimensions: various sizes available, please see Configurations or contact your Oberon representativeAP max. operating temperature should be de-rated by 9 °CTemperature rating: -30 to 115° C

Standards for SafetyDesigned to NEMA 3R, 4, 4X, 12, and 6P, and IEC529-IP68 specifications for indoor/ outdoor wet, dirty, or corrosive environmentsUL508 listed; back-box and cover are light gray UL94-5VA Polycarbonate; tinted clear cover is UL94V-0 Polycarbonate

Measurements (Maximum values):

• Height: 24 in.• Width: 24 in.• Depth: 10 in.• Item Weight: 7 lbs.• Shipping Weight: 7 lbs.

175

Page 176: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(4) #8 - 32 screw(4) Mounting feet(4) #10 - 32 mounting feet screwInstallation instructions

Available AccessoriesAccessories

39-POLE-MOUNT-BRACKET - Model 1020, Model 1024: Pole Mount Kit39-RJ45-BULKHEAD - Bulkhead Modular Pass -Through

Cables for Oberon Antennas & Enclosures

39-BULKHD-KIT-RPTNC(F) - Pigtail Cable for Antennas on Enclosure Door - RPTNC39-BULKHD-KIT-RPSMA - Pigtail Cable for Antennas on Enclosure Door - RPSM39-CORD-GRIP - Cable ingress/egress fitting

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2090&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1026-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1026-00_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Model1025-00_coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

176

Page 177: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1026-CPolycarbonate NEMA4 WiFi AP Box-12x10x6 clear door

Category: Indoor/Outdoor NEMA

NEMA 4X enclosure protects APs with internal or external antennas from allvendors in challenging indoor/outdoor environments. This rugged polycarbonateenclosure protects the AP from weather, dust, and impacts, and is transparent towireless signals so APs with body integrated antennas or small detachableantennas may be protected. The enclosure has a hinged door, molded-in padlockhasps for locking, and interior ABS panel for attaching APs. Paintable. Convenientsizes are available.

Features & Benefits

Compact, low-profile wireless access point enclosure for indoor and outdoor applications such as stadiums and public hotspotsUV-stabilized for exposure to direct sunlightVirtually transparent to wireless signalsUniversal mounting plate allows easy installation of most vendors’ APsCover is hinged; cover can be latched and locked with padlock (not included)Tinted clear polycarbonate cover is available upon request; please specify as “-C” in model number

Technical SpecificationsDesign: Polycarbonate NEMA wireless access point enclosure designed for wall or mast mounting indoors or outdoors, wheresecure mounting is required. Large enough for Cisco 3500/3600 wireless access points. Tinted clear, fully-hinged, lockable door.Performance: Designed to NEMA 3R, 4, 4X, 12, and 6P, and IEC529-IP68 specifications for indoor/outdoor wet, dirty, or corrosiveenvironments. UV-stabilized for exposure to direct sunlight. Transparent to wireless signals. Paintable.AP max. operating temperature should be de-rated by 9 °CTemperature rating: -30 to 115° CTinted clear, fully-hinged, gasketed door with hasps for padlockInternal plastic universal mounting panelConstruction: UL listed to UL50 and UL508A; back-box is light gray UL94-5VA polycarbonate plastic; door is clear polycarbonateplasticSize: 11.6 inches by 13.4 inches by 7.6 inches (295 mm by 340 mm by 193 mm)

Standards for SafetyDesigned to NEMA 3R, 4, 4X, 12, and 6P, and IEC529-IP68 specifications for indoor/ outdoor wet, dirty, or corrosive environmentsUL508 listed; back-box and cover are light gray UL94-5VA Polycarbonate; tinted clear cover is UL94V-0 Polycarbonate

Measurements (Maximum values):

• Height: 11.6 in.• Width: 13.4 in.• Depth: 7.6 in.• Item Weight: 7 lbs.• Shipping Weight: 7 lbs.

177

Page 178: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Unit(4) #8 - 32 screw(4) Mounting feet(4) #10 - 32 mounting feet screwInstallation instructions

Available AccessoriesAccessories

39-POLE-MOUNT-BRACKET - Model 1020, Model 1024: Pole Mount Kit39-RJ45-BULKHEAD - Bulkhead Modular Pass -Through

Cables for Oberon Antennas & Enclosures

39-BULKHD-KIT-RPTNC(F) - Pigtail Cable for Antennas on Enclosure Door - RPTNC39-BULKHD-KIT-RPSMA - Pigtail Cable for Antennas on Enclosure Door - RPSM39-CORD-GRIP - Cable ingress/egress fitting

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2054&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1026-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1026-00_Customer_Print.pdf

App Note - Wireless Coverage FAQ - oberoninc.com/images/WebDocs/Model1025-00_coverage_FAQ.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

178

Page 179: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1028-04-ANT5-BAluminum NEMA4 AP Enclosure:4" deep Recessed

Category: Suspended Ceiling Zone and A/V Enclosures

Hard lid ceiling enclosure protects critical wireless access points, DAS remoteunits, and public safety equipment with detachable antennas. This water- anddust-proof steel enclosure has knockouts in the hinged door for ceiling-mountedantennas or water-resistant bulkhead connectors for antennas. Deep enough forthe Cisco 3600 series and other large APs and DAS remote access units withexternal connectors and up to five antennas. Plenum-rated; provides NEMA 4dust and water protection.

Features & Benefits• Universal T-bar mounting bracket allows easy installation of most vendors’ access points• Durable, attractive textured powder coat finish matches most ceiling tiles• Holes and plugs in cover and back-box for field installed, external, body mount antennas or bulkheadconnectors; see Accessories• Fully-hinged door clamps to the back-box with keyed quarter turn latch for a watertight seal• Enclosure back-box is an effective dust barrier to simplify ICRA procedure compliance in Hospitals

Technical SpecificationsDesign: Hard lid, recessed, ceiling enclosure protects critical wireless access points, DAS remote units, and public safetyequipment with detachable antennas. This water- and dust-proof steel enclosure has knockouts in the hinged door for ceiling-mounted antennas or water-resistant bulkhead connectors for antennas.Configuration: Model 1028-04-ANT5-B: 4.5 inches (114 mm) deep, door with 5 openings and plugs for antennasConfiguration: Model 1028-08-ANT5-B: 9.1 inches (231 mm) deep, door with 5 openings and plugs for antennasPerformance: Designed to NEMA 1, 2, 3R, 4, 5, 12, 12k, and IEC529-IP66 specifications for indoor/outdoor wet, dirty, or corrosiveenvironments. UL-Listed and designed to satisfy National Electric Code (NEC) paragraphs 300-22 and 300-23 for installation in theair-handling space. OSHPD approved.Fully-hinged door clamps to the back-box with keyed quarter turn latch for a watertight seal; door has mounting features for up to5 antennasHoles and plugs in cover and back-box for field installed, external, body mount antennas or bulkhead connectorsIncludes internal universal mounting panel, T-bar bracket, hole plugs, and hanger wireConstruction: White, 12 ga. powder-coated aluminum back-box and door, white, 18 ga. powder-coated steel bezelEnclosure shall be supported by the building ceiling structural system, not tile grid workMaximum weight inside enclosure is 25 lbs.AP max. operating temperature should be de-rated by 6° C inside the enclosureSize: Bezel is 20.1 inches by 20.1 inches (510 mm by 510 mm); enclosure is 15.75 inches by 13.9 inches by 4.5 or 9.1 inches deep(400 mm by 353 mm by 114 mm or 231 deep)

Standards for SafetyRecessed hard lid ceiling enclosure meets NEMA 1, 2, 3R, 4, 5, 12, 12k and IP66 for protection of critical wireless, networking, andpublic safety equipment in ceiling spacesUL Listed and designed to meet National Electric Code paragraph 300-22(C) and 300-23 for use in the above-ceiling (plenum)space

179

Page 180: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 20.1 in. (15.75 in.)• Width: 20.1 in. (13.9 in.)• Depth: 4.5 in.• Item Weight: 11 lbs.• Shipping Weight: 22 lbs.

Includes(1) Unit(1) Internal universal equipment mounting panel and T-bar bracket(8) Hanger wires(4) Screw caps (-B units only)(4) Self-tapping screws(4) #8 Hex nuts(4) 1/2" Trade size hole plugs(3) 1" Trade size hole plugs(4) Hinged snap cap(4) #8 pan head screwInstallation instructions

Available Accessories34-BMANT24 - 2.4 GHz Single Band WiFi Antenna: NEMA4 Enclosures34-BMANT5 - 5 GHz Single Band WiFi Antenna: NEMA4 Enclosures34-DMDUAL - Dual Band WiFi Antenna: NEMA4 Enclosures39-CORD-GRIP - Cable ingress/egress fittingGasket material for external antenna

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1364&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1028-04-ANT5-B_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1028-04-ANT5-B_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

180

Page 181: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1028-04-ANT5-FAluminum NEMA4 AP Enclosure:4" deep Susp ceiling

Category: Suspended Ceiling Zone and A/V Enclosures

Hard lid ceiling enclosure protects critical wireless access points, DAS remoteunits, and public safety equipment with detachable antennas. This water- anddust-proof steel enclosure has knockouts in the hinged door for ceiling-mountedantennas or water-resistant bulkhead connectors for antennas. Deep enough forthe Cisco 3600 series and other large APs and DAS remote access units withexternal connectors and up to five antennas. Plenum-rated; provides NEMA 4dust and water protection.

Features & Benefits• Universal T-bar mounting bracket allows easy installation of most vendors’ access points• Durable, attractive textured powder coat finish matches most ceiling tiles• Holes and plugs in cover and back-box for field installed, external, body mount antennas or bulkheadconnectors; see Accessories• Fully-hinged door clamps to the back-box with keyed quarter turn latch for a watertight seal• Enclosure back-box is an effective dust barrier to simplify ICRA procedure compliance in Hospitals

Technical SpecificationsDesign: Suspended ceiling enclosure protects critical wireless access points, DAS remote units, and public safety equipment withdetachable antennas. This water- and dust-proof steel enclosure has knockouts in the hinged door for ceiling-mounted antennasor water-resistant bulkhead connectors for antennas.Configuration: Model 1028-04-ANT5-F: 4.5 inches (114 mm) deep, door with 5 openings and plugs for antennasConfiguration: Model 1028-08-ANT5-F: 9.1 inches (231 mm) deep, door with 5 openings and plugs for antennasPerformance: Designed to NEMA 1, 2, 3R, 4, 5, 12, 12k, and IEC529-IP66 specifications for indoor/outdoor wet, dirty, or corrosiveenvironments. UL-Listed and designed to satisfy National Electric Code (NEC) paragraphs 300-22 and 300-23 for installation in theair-handling space. OSHPD approved.Fully-hinged door clamps to the back-box with keyed quarter turn latch for a watertight seal; door has mounting features for up to5 antennasHoles and plugs in cover and back-box for field-installed, external, body mount antennas or bulkhead connectorsIncludes internal universal mounting panel, T-bar bracket, hole plugs, and hanger wireConstruction: White, 12 ga. powder-coated aluminum back-box and door; white, 18 ga. powder-coated steel bezelEnclosure shall be supported by the building ceiling structural system, not tile grid workMaximum weight inside enclosure is 25 lbs.AP max. operating temperature should be de-rated by 6° C inside the enclosureSize: Bezel is 20.1 inches by 20.1 inches (510 mm by 510 mm), enclosure is 15.75 inches by 13.9 inches by 4.5 or 9.1 inches deep(400 mm by 353 mm by 114 mm or 231 deep).

Standards for SafetyRecessed hard lid ceiling enclosure meets NEMA 1, 2, 3R, 4, 5, 12, 12k and IP66 for protection of critical wireless, networking, andpublic safety equipment in ceiling spacesUL Listed and designed to meet National Electric Code paragraph 300-22(C) and 300-23 for use in the above-ceiling (plenum)space

181

Page 182: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 23.75 in. (15.75 in.)• Width: 23.75 in. (13.9 in.)• Depth: 4.5 in.• Item Weight: 14 lbs.• Shipping Weight: 22 lbs.

Includes(1) Unit(1) Internal universal equipment mounting panel and T-bar bracket(8) Hanger wires(4) Screw caps (-B units only)(4) Self-tapping screws(4) #8 Hex nuts(4) 1/2" Trade size hole plugs(3) 1" Trade size hole plugs(4) Hinged snap cap(4) #8 pan head screwInstallation instructions

Available Accessories34-BMANT24 - 2.4 GHz Single Band WiFi Antenna: NEMA4 Enclosures34-BMANT5 - 5 GHz Single Band WiFi Antenna: NEMA4 Enclosures34-DMDUAL - Dual Band WiFi Antenna: NEMA4 Enclosures39-CORD-GRIP - Cable ingress/egress fittingGasket material for external antenna

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1366&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1028-04-ANT5-F_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1028-04-ANT5-F_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

182

Page 183: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1028-08-ANT5-BAluminum NEMA4 AP Enclosure:8" deep Recessed

Category: Suspended Ceiling Zone and A/V Enclosures

Hard lid ceiling enclosure protects critical wireless access points, DAS remoteunits, and public safety equipment with detachable antennas. This water- anddust-proof steel enclosure has knockouts in the hinged door for ceiling-mountedantennas or water-resistant bulkhead connectors for antennas. Deep enough forthe Cisco 3600 series and other large APs and DAS remote access units withexternal connectors and up to five antennas. Plenum-rated; provides NEMA 4dust and water protection.

Features & Benefits• Universal T-bar mounting bracket allows easy installation of most vendors’ access points• Durable, attractive textured powder coat finish matches most ceiling tiles• Holes and plugs in cover and back-box for field installed, external, body mount antennas or bulkheadconnectors; see Accessories• Fully-hinged door clamps to the back-box with keyed quarter turn latch for a watertight seal• Enclosure back-box is an effective dust barrier to simplify ICRA procedure compliance in Hospitals

Technical SpecificationsDesign: Hard lid, recessed, ceiling enclosure protects critical wireless access points, DAS remote units, and public safetyequipment with detachable antennas. This water- and dust-proof steel enclosure has knockouts in the hinged door for ceiling-mounted antennas or water-resistant bulkhead connectors for antennas.Configuration: Model 1028-04-ANT5-B: 4.5 inches (114 mm) deep, door with 5 openings and plugs for antennasConfiguration: Model 1028-08-ANT5-B: 9.1 inches (231 mm) deep, door with 5 openings and plugs for antennasPerformance: Designed to NEMA 1, 2, 3R, 4, 5, 12, 12k, and IEC529-IP66 specifications for indoor/outdoor wet, dirty, or corrosiveenvironments. UL-Listed and designed to satisfy National Electric Code (NEC) paragraphs 300-22 and 300-23 for installation in theair-handling space. OSHPD approved.Fully-hinged door clamps to the back-box with keyed quarter turn latch for a watertight seal; door has mounting features for up to5 antennasHoles and plugs in cover and back-box for field installed, external, body mount antennas or bulkhead connectorsIncludes internal universal mounting panel, T-bar bracket, hole plugs, and hanger wireConstruction: White, 12 ga. powder-coated aluminum back-box and door, white, 18 ga. powder-coated steel bezelEnclosure shall be supported by the building ceiling structural system, not tile grid workMaximum weight inside enclosure is 25 lbs.AP max. operating temperature should be de-rated by 6° C inside the enclosureSize: Bezel is 20.1 inches by 20.1 inches (510 mm by 510 mm); enclosure is 15.75 inches by 13.9 inches by 4.5 or 9.1 inches deep(400 mm by 353 mm by 114 mm or 231 deep)

Standards for SafetyRecessed hard lid ceiling enclosure meets NEMA 1, 2, 3R, 4, 5, 12, 12k and IP66 for protection of critical wireless, networking, andpublic safety equipment in ceiling spacesUL Listed and designed to meet National Electric Code paragraph 300-22(C) and 300-23 for use in the above-ceiling (plenum)space

183

Page 184: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 20.1 in. (15.75 in.)• Width: 20.1 in. (13.9 in.)• Depth: 9.1 in.• Item Weight: 15 lbs.• Shipping Weight: 22 lbs.

Includes(1) Unit(1) Internal universal equipment mounting panel and T-bar bracket(8) Hanger wires(4) Screw caps (-B units only)(4) Self-tapping screws(4) #8 Hex nuts(4) 1/2" Trade size hole plugs(3) 1" Trade size hole plugs(4) Hinged snap cap(4) #8 pan head screwInstallation instructions

Available Accessories34-BMANT24 - 2.4 GHz Single Band WiFi Antenna: NEMA4 Enclosures34-BMANT5 - 5 GHz Single Band WiFi Antenna: NEMA4 Enclosures34-DMDUAL - Dual Band WiFi Antenna: NEMA4 Enclosures39-CORD-GRIP - Cable ingress/egress fittingGasket material for external antenna

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1292&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1028-08-ANT5-B_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1028-08-ANT5-B_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

184

Page 185: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1028-08-ANT5-FAluminum NEMA4 AP Enclosure:8" deep Susp ceiling

Category: Suspended Ceiling Zone and A/V Enclosures

Hard lid ceiling enclosure protects critical wireless access points, DAS remoteunits, and public safety equipment with detachable antennas. This water- anddust-proof steel enclosure has knockouts in the hinged door for ceiling-mountedantennas or water-resistant bulkhead connectors for antennas. Deep enough forthe Cisco 3600 series and other large APs and DAS remote access units withexternal connectors and up to five antennas. Plenum-rated; provides NEMA 4dust and water protection.

Features & Benefits• Universal T-bar mounting bracket allows easy installation of most vendors’ access points• Durable, attractive textured powder coat finish matches most ceiling tiles• Holes and plugs in cover and back-box for field installed, external, body mount antennas or bulkheadconnectors; see Accessories• Fully-hinged door clamps to the back-box with keyed quarter turn latch for a watertight seal• Enclosure back-box is an effective dust barrier to simplify ICRA procedure compliance in Hospitals

Technical SpecificationsDesign: Suspended ceiling enclosure protects critical wireless access points, DAS remote units, and public safety equipment withdetachable antennas. This water- and dust-proof steel enclosure has knockouts in the hinged door for ceiling-mounted antennasor water-resistant bulkhead connectors for antennas.Configuration: Model 1028-04-ANT5-F: 4.5 inches (114 mm) deep, door with 5 openings and plugs for antennasConfiguration: Model 1028-08-ANT5-F: 9.1 inches (231 mm) deep, door with 5 openings and plugs for antennasPerformance: Designed to NEMA 1, 2, 3R, 4, 5, 12, 12k, and IEC529-IP66 specifications for indoor/outdoor wet, dirty, or corrosiveenvironments. UL-Listed and designed to satisfy National Electric Code (NEC) paragraphs 300-22 and 300-23 for installation in theair-handling space. OSHPD approved.Fully-hinged door clamps to the back-box with keyed quarter turn latch for a watertight seal; door has mounting features for up to5 antennasHoles and plugs in cover and back-box for field-installed, external, body mount antennas or bulkhead connectorsIncludes internal universal mounting panel, T-bar bracket, hole plugs, and hanger wireConstruction: White, 12 ga. powder-coated aluminum back-box and door; white, 18 ga. powder-coated steel bezelEnclosure shall be supported by the building ceiling structural system, not tile grid workMaximum weight inside enclosure is 25 lbs.AP max. operating temperature should be de-rated by 6° C inside the enclosureSize: Flange is 23.75 inches by 23.75 inches (603 mm by 603 mm), enclosure is 15.75 inches by 13.9 inches by 4.5 or 9.1 inchesdeep (400 mm by 353 mm by 114 mm or 231 deep)

Standards for SafetyRecessed hard lid ceiling enclosure meets NEMA 1, 2, 3R, 4, 5, 12, 12k and IP66 for protection of critical wireless, networking, andpublic safety equipment in ceiling spacesUL Listed and designed to meet National Electric Code paragraph 300-22(C) and 300-23 for use in the above-ceiling (plenum)space

185

Page 186: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 23.75 in. (15.75 in.)• Width: 23.75 in. (13.9 in.)• Depth: 9.1 in.• Item Weight: 18 lbs.• Shipping Weight: 22 lbs.

Includes(1) Unit(1) Internal universal equipment mounting panel and T-bar bracket(8) Hanger wires(4) Screw caps (-B units only)(4) Self-tapping screws(4) #8 Hex nuts(4) 1/2" Trade size hole plugs(3) 1" Trade size hole plugs(4) Hinged snap cap(4) #8 pan head screwInstallation instructions

Available Accessories34-BMANT24 - 2.4 GHz Single Band WiFi Antenna: NEMA4 Enclosures34-BMANT5 - 5 GHz Single Band WiFi Antenna: NEMA4 Enclosures34-DMDUAL - Dual Band WiFi Antenna: NEMA4 Enclosures39-CORD-GRIP - Cable ingress/egress fittingGasket material for external antenna

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1293&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1028-08-ANT5-F_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1028-08-ANT5-F_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

186

Page 187: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 3010Stadium Underseat Enclosure for APs

Category: Indoor/Outdoor NEMA

The Model 3010 protects APs mounted beneath seats in high density WiFideployments in public venues. The 3010 is large enough for most enterprise APs,yet is compact enough to fit under the seat without impeding foot space. Thisunit is comprised of an aluminum back plane and durable thermoformed plasticcover with a gasket for outdoor installation. The plastic can be easily drilled forcable egress. The thermoform plastic is virtually transparent to wireless signals.

Features & Benefits

Rugged under-seat enclosure for installing APs in stadium venues and other challenging environmentsDesigned for use in indoor/outdoor wet, or dirty environments; UV capped for exposure to direct sunlightVirtually transparent to wireless signalsPlastic is easily drilled and machined for custom cable ingress and installationCover attaches with 14 stainless steel cap nuts; weather and abrasion resistant EPDM foam strip provides seal

Technical SpecificationsDesign: Enclosure designed to protect wireless access point and antenna when mounted under seats in auditorium or stadium.Fastens to riser. Screw-on Acrylic/PVC alloy plastic cover.Performance: Designed to protect equipment from spilling liquids, weather and washing for indoor/outdoor applications.Transparent to wireless signals. Paintable. De-rate AP operating temperature range by 9°C when mounted in enclosure.Includes articulating universal access point mounting bracketEPDM foam gasketConstruction: Cover is light grey, thermoformed UL94-V0 Acrylic/PVC alloy plastic; UV capped for exposure to direct sunlight;back plane is 10 ga. aluminumSize: 9.16 inches by 16.60 inches by 11.25 inches (232 mm by 422 mm by 286 mm)

Measurements (Maximum values):

• Height: 9.16 in.• Width: 16.6 in.• Depth: 11.25 in.• Item Weight: 6 lbs.• Shipping Weight: 8 lbs.

187

Page 188: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Includes(1) Acrylic/PVC alloy cover(1) Aluminum back plane(1) Adjustable T-Bar bracket(2) #8 Pan head machine screw(4) #8 Machine nut(14) #8 Machine cap nut(14) #8 Lock washer(1) Installation instructions

Available Accessories39-CORD-GRIP - Cord Grip Connector for Pre-Terminated Cables39-RJ45-BULKHEAD - Bulkhead Modular Pass -Through

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2533&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model3010-00_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model3010-00_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

188

Page 189: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 3015-WEUnderseat AP/Antenna Enclosure; Wide

Category: Indoor/Outdoor NEMA

Enclosure designed to protect both wireless access point with attached dipoleantennas and external antenna(s) when mounted under seats in auditorium orstadium. Fastens to riser. Screw on Acrylic/PVC alloy plastic cover.

Technical Specifications

Design: Enclosure designed to protect both wireless access point with attached dipole antennas and external antenna(s) whenmounted under seats in auditorium or stadium. Fastens to riser. Screw on Acrylic/PVC alloy plastic cover.Performance: Designed to protect equipment from spilling liquids, weather and washing. Capable of NEMA 3R performance forindoor/outdoor wet environments when properly sealed. Transparent to wireless signals. Paintable.Includes articulating universal antenna and access point mounting bracketEPDM foam gasketSpanner panhead screws with gaskets to attach coverConstruction: Cover is light grey, thermoformed UL94-V0 Acrylic/PVC alloy plastic; UV capped for exposure to direct sunlight;back plane is 10 ga. aluminumSize: 29 inches by 8 inches by 7.3 inches (737 mm by 203 mm by 185 mm)

Measurements (Maximum values):

• Height: 8 in.• Width: 29 in.• Depth: 7.3 in.• Item Weight: N/A• Shipping Weight: N/A

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2643&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model3015-WE_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model3015-WE_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

189

Page 190: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 3020Handrail AP/Antenna Enclosure

Category: Indoor/Outdoor NEMA

Clam shell Acrylic/PVC alloy plastic enclosure designed to protect wirelessaccess point and antenna when mounted on handrails in auditorium or stadium.Center plane fastens to handrail. Available by special order only.

Technical Specifications

Design: Clam shell Acrylic/PVC alloy plastic enclosure designed to protect wireless access point and antenna when mounted onhandrails in auditorium or stadium. Center plane fastens to handrail.Performance: Designed to protect equipment from spilling liquids and weather. Capable of NEMA 3R performance forindoor/outdoor environments when properly sealed. Transparent to wireless signals. Paintable.Includes aluminum center plane with features to fasten access point and antenna; center plane fastens to lower handrail with U-Bolt clampEPDM foam gasketSpecify right pointing and left pointing antenna (Model 3020-R and 3020-L) Construction: 2 part clamshell, light grey, thermoformed UL94-V0 Acrylic/PVC alloy plastic; UV capped for exposure to directsunlight; center plane is 10ga. aluminumSize: 26.93 inches by 16.15 inches by 4.60 inches (684 mm by 410 mm by 117 mm)

Measurements (Maximum values):

• Height: 26.93 in.• Width: 16.15 in.• Depth: 4.60 in.• Item Weight: N/A• Shipping Weight: N/A

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2649&Itemid=399

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

190

Page 191: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1074-04-ANT72U Susp Ceiling Zone Enclosure-Up to 7 antennas

Category: Suspended Ceiling Zone and A/V Enclosures

Locking suspended ceiling enclosure mounts and secures general-purposetelecom/zone equipment and is a consolidation point for securing pre-terminated“plug-n-play" copper and fiber optic cable assemblies. Secure active equipment -Optical Network Terminals (ONTs), small workgroup switches, APs, and DASremote access units (RAUs). The only plenum-rated enclosure with fire-stoppedopenings for the multi-fiber array modules and multi-copper connector modulesused in pre-terminated solutions.

Features & Benefits

2' x 2' Ceiling tile telecommunications enclosure designed for pre-terminated “plug-n-play" copper and fiber optic cableassemblies in a zone structured cabling design. This is an ideal solution for installing non-plenum rated components in, or above,the ceilingAlso designed for non-plenum rated powered equipment, including Optical Network Terminals (ONTs), small workgroup switches,wireless access points, and DAS remote access units (RAUs).UL listed and designed to meet National Electric Code paragraph 300-22(C) for use in the above-ceiling (plenum) space. Metalenclosures satisfy UL 2043, Fire Test for Heat and Visible Smoke ReleaseInterchangeable doors allow for technology changes and upgrades without removing enclosure from the ceilingEnclosure back-box is effective smoke and dust barrier to simplify ICRA procedure complianceIncludes 19" internal rack mounting brackets for networking and wireless equipmentIncludes receptacle and junction box for plugging in ac powered equipmentCooling is provided by passive convection for Models 1074-04-VENT and 1074-06-VENT

Technical SpecificationsDesign: General-purpose telecommunications, ceiling mounted, consolidation enclosure, shall be a locking, 2 feet by 2 feet (610mm by 610 mm) ceiling tile enclosure designed to accommodate up to 3 standard (1U) rack-mountable components. Suitable fornon-plenum rated equipment.Configuration: Model 1074-04-ANT7: 4-1/2 inches (114 mm) deep, 2U rack mount brackets, non-ventilated door with 7 openingsfor antennasConfiguration: Model 1074-06-ANT7: 6-1/2 inches (165 mm) deep, 3U rack mount brackets, non-ventilated door with 7 openingsfor antennasPerformance: UL-Listed and designed to satisfy National Electric Code (NEC) paragraphs 300-22 and 300-23 for installation in theair-handling space. OSHPD approved.Fully-hinged locking door, keyed alike; door has mounting features for up to 7 antennasKnockouts for two AC receptacles, eight 1" trade size conduit connectors, and four 5” wide fire stopped openingsIncludes two 5” cable egress firestop foam kits, and one .75" trade size firestop foam kitIncludes pair of rack mount brackets, AC receptacle and junction box, and hanger wireConstruction: White, 10 ga. powder-coated aluminum back-box and flange; white, 8 ga. powder-coated aluminum doorEnclosure shall be supported by the building ceiling structural system, not tile grid workMaximum weight inside enclosure is 25 lbs.Size: Flange is 23.75 inches by 23.75 inches (610 mm by 610 mm); enclosure is 22.7 inches by 22.7 inches by 4.5 or 6.5 inchesdeep (577 mm by 577 mm by 115 mm deep)

191

Page 192: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Standards for SafetyOSHPD Approval OPM-110-13

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 4.5 in.• Item Weight: 21 lbs.• Shipping Weight: 21 lbs.

Includes(8) Wire hanger(1) UL listed electrical receptical box and cover(2) 4 RU rack-mounting bracket(4) Wire management J-Hooks(2) Large cable egress fire stop foam kit(1) Small cable egress fire stop foam kit(4) #6-20 3/8" self-tapping screw

Videos - https://www.youtube.com/user/oberoninc1074 Series Video View at https://youtu.be/hpU47qchFgQ

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1296&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1074_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1074-04-ANT7_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

192

Page 193: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1074-04-DOME3U Susp Ceiling Zone Enclosure-Ventilated, beveled

Category: Suspended Ceiling Zone and A/V Enclosures

Locking suspended ceiling enclosure secures general purpose telecom/zoneequipment and used for attaching (2) directional antennas and APs. Secureactive equipment including Optical Network Terminals (ONTs), small workgroupswitches, APs, DAS remote access units (RAUs), and directional antennas. Thedome is ABS plastic and virtually transparent to wireless signal. Fire-stoppedopenings for the multi-fiber array modules and multi-copper connector modulesused in pre-terminated solutions.

Features & Benefits

2' x 2' Ceiling tile telecommunications enclosure designed for pre-terminated "plug-n-play" copper and fiber optic cableassemblies in a zone structured cabling design. This is an ideal solution for installing non-plenum rated components in, or above,the ceilingAlso designed for non-plenum rated powered equipment, including Optical Network Terminals (ONTs), small workgroup switches,wireless access points, and DAS remote access units (RAUs).UL listed and designed to meet National Electric Code paragraph 300-22(C) for use in the above-ceiling (plenum) space. Metalenclosures satisfy UL 2043, Fire Test for Heat and Visible Smoke ReleaseInterchangeable doors allow for technology changes and upgrades without removing enclosure from the ceilingEnclosure back-box is effective smoke and dust barrier to simplify ICRA procedure complianceIncludes 19" internal rack mounting brackets for networking and wireless equipmentIncludes receptacle and junction box for plugging in ac powered equipmentCooling is provided by passive convection for Models 1074-04-VENT and 1074-06-VENT

Technical SpecificationsDesign: General-purpose telecommunications, ceiling mounted, consolidation enclosure, shall be a locking, 2 feet by 2 feet (610mm by 610 mm) ceiling tile enclosure designed to accommodate up to 3 standard (1U) rack-mountable components. Suitable fornon-plenum rated equipment.Performance: UL-Listed and designed to satisfy National Electric Code (NEC) paragraphs 300-22 and 300-23 for installation in theair-handling space. OSHPD approved.Fully-hinged locking door, keyed alike; door is ABS plastic and virtually transparent to wireless signalKnockouts for two AC receptacles, eight 1" trade size conduit connectors, and four 5" wide fire stopped openingsIncludes two 5" cable egress firestop foam kits, and one .75" trade size firestop foam kitIncludes pair of rack mount brackets, AC receptacle and junction box, and hanger wireConstruction: White, 10 ga. powder-coated aluminum back-box and flange; white, 8 ga. powder-coated aluminum doorEnclosure shall be supported by the building ceiling structural system, not tile grid workMaximum weight inside enclosure is 25 lbs.Size: Flange is 23.75 inches by 23.75 inches (610 mm by 610 mm); enclosure is 22.7 inches by 22.7 inches by 4.5 or 6.5 inchesdeep (577 mm by 577 mm by 115 mm deep); Dome is 358mm x 358mm x 99mm

Standards for SafetyOSHPD Approval OPM-110-13

193

Page 194: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 4.5 in.• Item Weight: 22 lbs.• Shipping Weight: 23 lbs.

Includes(8) Wire hanger(1) UL listed electrical receptical box and cover(2) 3 RU rack-mounting bracket(4) Wire management J-Hooks(2) Large cable egress fire stop foam kit(1) Small cable egress fire stop foam kit(4) #6-20 3/8" self-tapping screw

Videos - https://www.youtube.com/user/oberoninc1074 Series Video View at https://youtu.be/hpU47qchFgQ

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=3135&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1074-DOME_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1074-DOME_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

194

Page 195: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1074-04-VENT3U Susp Ceiling Zone Enclosure-Ventilated, beveled

Category: Suspended Ceiling Zone and A/V Enclosures

Locking suspended ceiling enclosure secures general purpose telecom/zoneequipment and is a consolidation point for securing pre-terminated “plug-n-play"copper and fiber optic cable assemblies. Secure active equipment includingOptical Network Terminals (ONTs), small workgroup switches, APs, and DASremote access units (RAUs). Patented ventilated door. Fire-stopped openings forthe multi-fiber array modules and multi-copper connector modules used in pre-terminated solutions.

Features & Benefits

2' x 2' Ceiling tile telecommunications enclosure designed for pre-terminated “plug-n-play" copper and fiber optic cableassemblies in a zone structured cabling design. This is an ideal solution for installing non-plenum rated components in, or above,the ceilingAlso designed for non-plenum rated powered equipment, including Optical Network Terminals (ONTs), small workgroup switches,wireless access points, and DAS remote access units (RAUs).UL listed and designed to meet National Electric Code paragraph 300-22(C) for use in the above-ceiling (plenum) space. Metalenclosures satisfy UL 2043, Fire Test for Heat and Visible Smoke ReleaseInterchangeable doors allow for technology changes and upgrades without removing enclosure from the ceilingEnclosure back-box is effective smoke and dust barrier to simplify ICRA procedure complianceIncludes 19" internal rack mounting brackets for networking and wireless equipmentIncludes receptacle and junction box for plugging in ac powered equipmentCooling is provided by passive convection for Models 1074-04-VENT and 1074-06-VENT

Technical SpecificationsDesign: General-purpose telecommunications, ceiling mounted, consolidation enclosure, shall be a locking, 2 feet by 2 feet (610mm by 610 mm) ceiling tile enclosure designed to accommodate up to 3 standard (1U) rack-mountable components. Suitable fornon-plenum rated equipment.Configuration: Model 1074-04-VENT: 4-1/2 inches (114 mm) deep; 2U rack mount brackets; beveled, ventilated doorConfiguration: Model 1074-06-VENT: 6-1/2 inches (165 mm) deep; 3U rack mount brackets; beveled, ventilated doorPerformance: UL-Listed and designed to satisfy National Electric Code (NEC) paragraphs 300-22 and 300-23 for installation in theair-handling space. OSHPD approved.Fully-hinged locking door, keyed alike; door is beveled and highly perforated for ventilationKnockouts for two AC receptacles, eight 1" trade size conduit connectors, and four 5” wide fire stopped openingsIncludes two 5” cable egress firestop foam kits, and one .75" trade size firestop foam kitIncludes pair of rack mount brackets, AC receptacle and junction box, and hanger wireConstruction: White, 10 ga. powder-coated aluminum back-box and flange; white, 8 ga. powder-coated aluminum doorEnclosure shall be supported by the building ceiling structural system, not tile grid workMaximum weight inside enclosure is 25 lbs.Size: Flange is 23.75 inches by 23.75 inches (610 mm by 610 mm); enclosure is 22.7 inches by 22.7 inches by 4.5 or 6.5 inchesdeep (577 mm by 577 mm by 115 mm deep)

Standards for SafetyOSHPD Approval OPM-110-13

195

Page 196: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 4.5 in.• Item Weight: 22 lbs.• Shipping Weight: 23 lbs.

Includes(8) Wire hanger(1) UL listed electrical receptical box and cover(2) 3 RU rack-mounting bracket(4) Wire management J-Hooks(2) Large cable egress fire stop foam kit(1) Small cable egress fire stop foam kit(4) #6-20 3/8" self-tapping screw

Videos - https://www.youtube.com/user/oberoninc1074 Series Video View at https://youtu.be/hpU47qchFgQ

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1297&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1074_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1074-04-VENT_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

196

Page 197: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1074-06-ANT73U Susp Ceiling Zone Enclosure-Up to 7 antennas

Category: Suspended Ceiling Zone and A/V Enclosures

Locking suspended ceiling enclosure mounts and secures general-purposetelecom/zone equipment and is a consolidation point for securing pre-terminated“plug-n-play" copper and fiber optic cable assemblies. Secure active equipment -Optical Network Terminals (ONTs), small workgroup switches, APs, and DASremote access units (RAUs). The only plenum-rated enclosure with fire-stoppedopenings for the multi-fiber array modules and multi-copper connector modulesused in pre-terminated solutions.

Features & Benefits

2' x 2' Ceiling tile telecommunications enclosure designed for pre-terminated “plug-n-play" copper and fiber optic cableassemblies in a zone structured cabling design. This is an ideal solution for installing non-plenum rated components in, or above,the ceilingAlso designed for non-plenum rated powered equipment, including Optical Network Terminals (ONTs), small workgroup switches,wireless access points, and DAS remote access units (RAUs).UL listed and designed to meet National Electric Code paragraph 300-22(C) for use in the above-ceiling (plenum) space. Metalenclosures satisfy UL 2043, Fire Test for Heat and Visible Smoke ReleaseInterchangeable doors allow for technology changes and upgrades without removing enclosure from the ceilingEnclosure back-box is effective smoke and dust barrier to simplify ICRA procedure complianceIncludes 19" internal rack mounting brackets for networking and wireless equipmentIncludes receptacle and junction box for plugging in AC powered equipmentCooling is provided by passive convection for Models 1074-04-VENT and 1074-06-VENT

Technical SpecificationsDesign: General-purpose telecommunications, ceiling mounted, consolidation enclosure, shall be a locking, 2 feet by 2 feet (610mm by 610 mm) ceiling tile enclosure designed to accommodate up to 3 standard (1U) rack-mountable components. Suitable fornon-plenum rated equipment.Configuration: Model 1074-04-ANT7: 4-1/2 inches (114 mm) deep, 2U rack mount brackets, non-ventilated door with 7 openingsfor antennasConfiguration: Model 1074-06-ANT7: 6-1/2 inches (165 mm) deep, 3U rack mount brackets, non-ventilated door with 7 openingsfor antennasPerformance: UL-Listed and designed to satisfy National Electric Code (NEC) paragraphs 300-22 and 300-23 for installation in theair-handling space. OSHPD approved.Fully-hinged locking door, keyed alike; door has mounting features for up to 7 antennasKnockouts for two AC receptacles, eight 1" trade size conduit connectors, and four 5” wide fire stopped openingsIncludes two 5” cable egress firestop foam kits, and one .75" trade size firestop foam kitIncludes pair of rack mount brackets, AC receptacle and junction box, and hanger wireConstruction: White, 10 ga. powder-coated aluminum back-box and flange; white, 8 ga. powder-coated aluminum doorEnclosure shall be supported by the building ceiling structural system, not tile grid workMaximum weight inside enclosure is 25 lbs.Size: Flange is 23.75 inches by 23.75 inches (610 mm by 610 mm); enclosure is 22.7 inches by 22.7 inches by 4.5 or 6.5 inchesdeep (577 mm by 577 mm by 115 mm deep)

197

Page 198: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Standards for SafetyOSHPD Approval OPM-110-13

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 6.5 in.• Item Weight: 22 lbs.• Shipping Weight: 23 lbs.

Includes(8) Wire hanger(1) UL listed electrical receptical box and cover(2) 3 RU rack-mounting bracket(4) Wire management J-Hooks(2) Large cable egress fire stop foam kit(1) Small cable egress fire stop foam kit(4) #6-20 3/8" self-tapping screw

Videos - https://www.youtube.com/user/oberoninc1074 Series Video View at https://youtu.be/hpU47qchFgQ

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1358&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1074_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1074-06-ANT7_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

198

Page 199: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1074-06-DOME3U Susp Ceiling Zone Enclosure-Ventilated, beveled

Category: Suspended Ceiling Zone and A/V Enclosures

Locking suspended ceiling enclosure secures general purpose telecom/zoneequipment and used for attaching (2) directional antennas and APs. Secureactive equipment including Optical Network Terminals (ONTs), small workgroupswitches, APs, DAS remote access units (RAUs), and directional antennas. Thedome is ABS plastic and virtually transparent to wireless signal. Fire-stoppedopenings for the multi-fiber array modules and multi-copper connector modulesused in pre-terminated solutions.

Features & Benefits

2' x 2' Ceiling tile telecommunications enclosure designed for pre-terminated “plug-n-play" copper and fiber optic cableassemblies in a zone structured cabling design. This is an ideal solution for installing non-plenum rated components in, or above,the ceilingAlso designed for non-plenum rated powered equipment, including Optical Network Terminals (ONTs), small workgroup switches,wireless access points, and DAS remote access units (RAUs).UL listed and designed to meet National Electric Code paragraph 300-22(C) for use in the above-ceiling (plenum) space. Metalenclosures satisfy UL 2043, Fire Test for Heat and Visible Smoke ReleaseInterchangeable doors allow for technology changes and upgrades without removing enclosure from the ceilingEnclosure back-box is effective smoke and dust barrier to simplify ICRA procedure complianceIncludes 19" internal rack mounting brackets for networking and wireless equipmentIncludes receptacle and junction box for plugging in ac powered equipmentCooling is provided by passive convection for Models 1074-04-VENT and 1074-06-VENT

Technical SpecificationsDesign: General-purpose telecommunications, ceiling mounted, consolidation enclosure, shall be a locking, 2 feet by 2 feet (610mm by 610 mm) ceiling tile enclosure designed to accommodate up to 3 standard (1U) rack-mountable components. Suitable fornon-plenum rated equipment.Performance: UL-Listed and designed to satisfy National Electric Code (NEC) paragraphs 300-22 and 300-23 for installation in theair-handling space. OSHPD approved.Fully-hinged locking door, keyed alike; door is ABS plastic and virtually transparent to wireless signalKnockouts for two AC receptacles, eight 1" trade size conduit connectors, and four 5" wide fire stopped openingsIncludes two 5" cable egress firestop foam kits, and one .75" trade size firestop foam kitIncludes pair of rack mount brackets, AC receptacle and junction box, and hanger wireConstruction: White, 10 ga. powder-coated aluminum back-box and flange; white, 8 ga. powder-coated aluminum doorEnclosure shall be supported by the building ceiling structural system, not tile grid workMaximum weight inside enclosure is 25 lbs.Size: Flange is 23.75 inches by 23.75 inches (610 mm by 610 mm); enclosure is 22.7 inches by 22.7 inches by 4.5 or 6.5 inchesdeep (577 mm by 577 mm by 115 mm deep); Dome is 358mm x 358mm x 99mm

Standards for SafetyOSHPD Approval OPM-110-13

199

Page 200: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 4.5 in.• Item Weight: 22 lbs.• Shipping Weight: 23 lbs.

Includes(8) Wire hanger(1) UL listed electrical receptical box and cover(2) 3 RU rack-mounting bracket(4) Wire management J-Hooks(2) Large cable egress fire stop foam kit(1) Small cable egress fire stop foam kit(4) #6-20 3/8" self-tapping screw

Videos - https://www.youtube.com/user/oberoninc1074 Series Video View at https://youtu.be/hpU47qchFgQ

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=3141&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1074-DOME_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1074-DOME_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

200

Page 201: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 1074-06-VENT4U Susp Ceiling Zone Enclosure-Ventilated, beveled

Category: Suspended Ceiling Zone and A/V Enclosures

Locking suspended ceiling enclosure secures general purpose telecom/zoneequipment and is a consolidation point for securing pre-terminated “plug-n-play"copper and fiber optic cable assemblies. Secure active equipment includingOptical Network Terminals (ONTs), small workgroup switches, APs, and DASremote access units (RAUs). Patented ventilated door. Fire-stopped openings forthe multi-fiber array modules and multi-copper connector modules used in pre-terminated solutions.

Features & Benefits

2' x 2' Ceiling tile telecommunications enclosure designed for pre-terminated “plug-n-play" copper and fiber optic cableassemblies in a zone structured cabling design. This is an ideal solution for installing non-plenum rated components in, or above,the ceilingAlso designed for non-plenum rated powered equipment, including Optical Network Terminals (ONTs), small workgroup switches,wireless access points, and DAS remote access units (RAUs).UL listed and designed to meet National Electric Code paragraph 300-22(C) for use in the above-ceiling (plenum) space. Metalenclosures satisfy UL 2043, Fire Test for Heat and Visible Smoke ReleaseInterchangeable doors allow for technology changes and upgrades without removing enclosure from the ceilingEnclosure back-box is effective smoke and dust barrier to simplify ICRA procedure complianceIncludes 19" internal rack mounting brackets for networking and wireless equipmentIncludes receptacle and junction box for plugging in AC powered equipmentCooling is provided by passive convection for Models 1074-04-VENT and 1074-06-VENT

Technical SpecificationsDesign: General-purpose telecommunications, ceiling mounted, consolidation enclosure, shall be a locking, 2 feet by 2 feet (610mm by 610 mm) ceiling tile enclosure designed to accommodate up to 3 standard (1U) rack-mountable components. Suitable fornon-plenum rated equipment.Configuration: Model 1074-04-VENT: 4-1/2 inches (114 mm) deep; 2U rack mount brackets; beveled, ventilated doorConfiguration: Model 1074-06-VENT: 6-1/2 inches (165 mm) deep; 3U rack mount brackets; beveled, ventilated doorPerformance: UL-Listed and designed to satisfy National Electric Code (NEC) paragraphs 300-22 and 300-23 for installation in theair-handling space. OSHPD approved.Fully-hinged locking door, keyed alike; door is beveled and highly perforated for ventilationKnockouts for two AC receptacles, eight 1" trade size conduit connectors, and four 5” wide fire stopped openingsIncludes two 5” cable egress firestop foam kits, and one .75” trade size firestop foam kitIncludes pair of rack mount brackets, AC receptacle and junction box, and hanger wireConstruction: White, 10 ga. powder-coated aluminum back-box and flange; white, 8 ga. powder-coated aluminum doorEnclosure shall be supported by the building ceiling structural system, not tile grid workMaximum weight inside enclosure is 25 lbs.Size: Flange is 23.75 inches by 23.75 inches (610 mm by 610 mm); enclosure is 22.7 inches by 22.7 inches by 4.5 or 6.5 inchesdeep (577 mm by 577 mm by 115 mm deep)

Standards for SafetyOSHPD Approval OPM-110-13

201

Page 202: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Measurements (Maximum values):

• Height: 23.75 in.• Width: 23.75 in.• Depth: 6.5 in.• Item Weight: 22 lbs.• Shipping Weight: 23 lbs.

Includes(8) Wire hanger(1) UL listed electrical receptical box and cover(2) 4 RU rack mounting bracket(4) Wire management J-Hooks(2) Large cable egress fire stop foam kit(1) Small cable egress fire stop foam kit(4) #6-20 3/8" self-tapping screw

Videos - https://www.youtube.com/user/oberoninc1074 Series Video View at https://youtu.be/hpU47qchFgQ

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1362&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1074_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model1074-06-VENT_Customer_Print.pdf

OSHPD OPM Drawing - http://oberoninc.com/images/WebDocs/Oberon_OPM.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

202

Page 203: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 33-ANT-COVERPaintable Antenna Vanity Cover- White ABS

Category: AP Vanity Covers

This simple vanity cover, large enough to conceal an Aruba Networks accesspoints and antenna. This item is formed from a durable, impact resistant ABSplastic which can be painted any color to match the environment, withoutvoiding the access point manufacturer’s warranty. The ABS plastic is virtuallytransparent to the wireless signal.

Features & Benefits

Conveniently conceal wireless access points, antennas, and cablesPaintable to match indoor or outdoor venuesImpact resistant white ABS plastic cover is virtually transparent to wireless signalsCover should be painted if exposed to direct sun light

Technical SpecificationsDesign: Paintable, white plastic vanity cover for access point and antennas. Conceal access points and antennas in manyenvironments. Suitable for most vendors' access points and antennas.Transparent to wireless signalConstruction: White UL94-5VA ABS plastic vanity cover; vanity cover should be sealed and painted in outdoor environmentsVanity cover size: 11.3 inches by 10 inches by 7.7 inches(287mm by 254mm by 195mm)

Measurements (Maximum values):

• Height: 10 in.• Width: 11.3 in.• Depth: 7.7 in.• Item Weight: 3 lbs.• Shipping Weight: 5 lbs.

Includes(1) 12" x 10.5" x 7" deep ABS cover(4) Plastic screw head capsInstallation Instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1668&Itemid=399

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

203

Page 204: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 33-AP3800-COVERIndoor AP Vanity Cover- Black ABS

Category: AP Vanity Covers

Attachable, paintable, black plastic vanity cover. Conceal access point in openceiling environments. Suitable for most vendors' access points and antennas.

Features & Benefits

Vanity cover for Cisco and other enterprise wireless access pointsThe vanity cover is virtually transparent to access point wireless signalsAttaches to access point with mushroom head fasteners (included)Vanity covers are paintable using an enamel spray paint such as Krylon (do not use oil based paint or metallic paint) and thesurface does not need to be treated

Technical SpecificationsDesign: Attachable, paintable, black plastic vanity cover. Conceal access point in open ceiling environments. Suitable for mostvendors' access points and antennas.Includes adhesive fasteners to attach cover to APConstruction: Black UL94-5VA ABS plastic; transparent to wireless signalSize: 8.9 inches by 8.9inches by 2.3 inches (325mm by 325mm by 48mm)

Measurements (Maximum values):

• Height: 8.9 in.• Width: 8.9 in.• Depth: 2.3 in.• Item Weight: N/A• Shipping Weight: N/A

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2718&Itemid=399

Customer Prints - oberoninc.com/images/WebDocs/33-AP3800-COVER_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

204

Page 205: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 33-AP-COVERIndoor AP Vanity Cover- Black ABS

Category: AP Vanity Covers

Features & Benefits

Vanity cover for Cisco and other enterprise wireless access pointsThe vanity cover is virtually transparent to access point wireless signalsAttaches to access point with mushroom head fasteners (included)Vanity covers are paintable using an enamel spray paint such as Krylon (do not use oil based paint or metallic paint) and thesurface does not need to be treated

Technical SpecificationsDesign: Attachable, paintable, black plastic vanity cover. Conceal access point in open ceiling environments. Suitable for mostvendors' access points and antennas.Includes adhesive fasteners to attach cover to APConstruction: Black UL94-5VA ABS plastic; transparent to wireless signal.Size: 8.8 inches by 8.8 inches by 2.1 inches (224mm by 224mm by 53mm)

Measurements (Maximum values):

• Height: 8.8 in• Width: 8.8 in.• Depth: 2.1 in.• Item Weight: N/A• Shipping Weight: N/A

IncludesOrdering Information: P/N 33-AP-COVERFour (4) mushroom head fastener

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1309&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/ModelCCOAPi-SKIN_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/33-AP-COVER_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

205

Page 206: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 33-HLA-COVERIndoor Cisco HLA Antenna/AP Vanity Cover-Black ABS

Category: AP Vanity Covers

Oberon’s 33-HLA-COVER customizes the appearance of the popular Cisco HyperLocation Antenna (HLA) and APs. The vanity cover is made from a wireless signaltransparent plastic, and can be attached directly to the Cisco enterprise APs. The33-HLA-COVER is paintable so you can customize the color of the antenna andAP to partially conceal the AP or compliment interior color schemes. Coloring thevanity cover does not void the manufacturer’s warranty. Includes coverfasteners.

Technical Specifications

Design: Attachable, paintable, black plastic vanity cover. Conceal access point in open ceiling environments. Suitable for Cisco APand HLA antenna.Includes adhesive fasteners to attach cover to APConstruction: Black UL94-5VA ABS plastic; transparent to wireless signalSize: 12.8 inches by 12.8 inches by 1.9 inches (325mm by 325mm by 48mm)

Measurements (Maximum values):

• Height: 12.8 in.• Width: 12.8 in.• Depth: 1.9 in.• Item Weight: N/A• Shipping Weight: N/A

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2521&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/ModelCCOAPi-SKIN_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/33-HLA-COVER_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

206

Page 207: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 33-IW3700-COVERAP Vanity Cover for Cisco IW3700

Category: AP Vanity Covers, Ceiling Mounting Accessories

Paintable, grey plastic vanity cover for Cisco IW3700 access point and antennas.Conceal access points and antennas in many environments, indoors andoutdoors.

Technical Specifications

Design: Paintable, grey plastic vanity cover for Cisco IW3700 access point and antennas. Conceal access points and antennas inmany environments, indoors and outdoors.Transparent to wireless signalConstruction: Gray UL94-V0 Acrylic/PVC Alloy plastic vanity cover; UV capped for exposure to direct sunlightVanity cover size: 13 inches by 13 inches by 5.6inches (330mm by 330mm by 142mm)

Measurements (Maximum values):

• Height: 13 in.• Width: 13 in.• Depth: 5.6 in.• Item Weight: N/A• Shipping Weight: N/A

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2724&Itemid=399

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

207

Page 208: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 33-MR-COVERIndoor Meraki AP Vanity Cover- Black ABS

Category: AP Vanity Covers

Oberon’s 33-MR-COVER customizes the appearance of the popular Merakiwireless access points. The vanity cover is made from a wireless signaltransparent plastic, and can be attached directly to the Meraki enterprisewireless access points. The 33-MR-COVER is paintable so you can customize thecolor of the access point to partially conceal the access point or complimentinterior color schemes. Coloring the vanity cover does not void themanufacturer’s warranty. Includes cover fasteners.

Technical Specifications

Design: Attachable, paintable, black plastic vanity cover. Conceal access point in open ceiling environments. Suitable for MerakiMR 32, 34 and 42 access points.Includes adhesive fasteners to attach cover to APConstruction: Black UL94-5VA ABS plastic; transparent to wireless signalSize: 10.3 inches by 6.5 inches by 1.7 inches (262mm by165mm by 43mm)

Measurements (Maximum values):

• Height: 6.5 in.• Width: 10.3 in.• Depth: 1.7 in.• Item Weight: N/A• Shipping Weight: N/A

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2527&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/ModelCCOAPi-SKIN_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/33-MR-COVER_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

208

Page 209: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 37-104X-AP215Retrofit Trim for Oberon 104X

Category: Retrofit Doors for Oberon Enclosures

Features & Benefits

Easily replace trim to migrate to a new access point or antenna

Measurements (Maximum values):

• Height: 10 in.• Width: 10 in.• Depth: 3 in.• Item Weight: N/A• Shipping Weight: N/A

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2747&Itemid=399

Customer Prints - oberoninc.com/images/WebDocs/Oberon_37-4X_Series_Retrofit_Doors.pdf

Series Spec Sheet - oberoninc.com/images/WebDocs/Oberon_37-4X_Series_Retrofit_Doors.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

209

Page 210: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 37-104X-AP215-FRetrofit Trim for Oberon 104X

Category: Retrofit Doors for Oberon Enclosures

Features & BenefitsEasily replace trim to migrate to a new access point or antenna

Measurements (Maximum values):

• Height: 14.5 in.• Width: 14.5 in.• Depth: 3 in.• Item Weight: N/A• Shipping Weight: N/A

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2753&Itemid=399

Customer Prints - oberoninc.com/images/WebDocs/Oberon_37-4X_Series_Retrofit_Doors.pdf

Series Spec Sheet - oberoninc.com/images/WebDocs/Oberon_37-4X_Series_Retrofit_Doors.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

210

Page 211: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 37-104X-AP225Retrofit Trim for Oberon 104X

Category: Retrofit Doors for Oberon Enclosures

Features & Benefits

Easily replace trim to migrate to a new access point or antenna

Measurements (Maximum values):

• Height: 10 in.• Width: 10 in.• Depth: 3 in.• Item Weight: N/A• Shipping Weight: N/A

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2760&Itemid=399

Customer Prints - oberoninc.com/images/WebDocs/Oberon_37-4X_Series_Retrofit_Doors.pdf

Series Spec Sheet - oberoninc.com/images/WebDocs/Oberon_37-4X_Series_Retrofit_Doors.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

211

Page 212: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 37-104X-CCOAPRetrofit Trim for Oberon 104X

Category: Retrofit Doors for Oberon Enclosures

This retrofit trim is designed to provide a convenient way to mount and securewireless access points in 104X Series AP mounting kits. The existing trim can beeasily removed and replaced with the new retrofit trim.

Features & Benefits

Easily replace trim to migrate to a new access point or antenna

Technical SpecificationsDesign: Removable trim assembly for Oberon Model 104X recess ceiling mounts for access points. Designed for Cisco accesspoints.Construction: White powder-coated steel trim, steel access point bracketSize: 10 inches by 10 inches by 3 inches ( 254 mm by 254 mm by 76 mm)

Measurements (Maximum values):

• Height: 10 in.• Width: 10 in.• Depth: 3 in.• Item Weight: N/A• Shipping Weight: N/A

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2730&Itemid=399

Customer Prints - oberoninc.com/images/WebDocs/Oberon_37-4X_Series_Retrofit_Doors.pdf

Series Spec Sheet - oberoninc.com/images/WebDocs/Oberon_37-4X_Series_Retrofit_Doors.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

212

Page 213: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 37-104X-CCOAP-FRetrofit Trim for Oberon 104X

Category: Retrofit Doors for Oberon Enclosures

This retrofit trim is designed to provide a convenient way to mount and securewireless access points in 104X Series AP mounting kits. The existing trim can beeasily removed and replaced with the new retrofit trim.

Features & Benefits

Easily replace trim to migrate to a new access point or antenna

Technical SpecificationsDesign: Removable trim assembly for Oberon Model 104X recess ceiling mounts for access points. Attaches to front of recessmount, so that ceiling tiles do not need to be lifted when replacing trim assembly. Designed for Cisco access points.Construction: White powder-coated steel trim, steel access point bracketSize: 14.5 inches by 14.5 inches by 3 inches (368 mm by 368 mm by 76 mm)

Measurements (Maximum values):

• Height: 14.5 in.• Width: 14.5 in.• Depth: 3 in.• Item Weight: N/A• Shipping Weight: N/A

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2741&Itemid=399

Customer Prints - oberoninc.com/images/WebDocs/Oberon_37-4X_Series_Retrofit_Doors.pdf

Series Spec Sheet - oberoninc.com/images/WebDocs/Oberon_37-4X_Series_Retrofit_Doors.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

213

Page 214: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 38-7X-CCOAPModel 107X Retrofit Door- Cisco APs

Category: Retrofit Doors for Oberon Enclosures

This locking retrofit door is designed to provide a convenient way to mount andsecure Cisco wireless access points in 1075, 1076, 1077, and 1078 Series APenclosures. Simply unlock door and remove three nuts from hinge to replacedoor. Simplify equipment replacement without lifting ceiling tiles.

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1316&Itemid=399

Customer Prints - oberoninc.com/images/WebDocs/Oberon_38-7X_Series_Retrofit_Doors.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

214

Page 215: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 38-7X-CPModel 107X Retrofit Door- Clear polycarbonate dome

Category: Retrofit Doors for Oberon Enclosures

This locking retrofit door is designed to provide a convenient way to mount andsecure most vendors APs and Apple TV Internet Gateway in model 1075, 1076,1077, and 1078 Series AP enclosures. Simply unlock door and remove three nutsfrom hinge to replace door. Clear polycarbonate dome is UL classified andvirtually transparent to wireless and IR signals. Simplify equipment replacementwithout lifting ceiling tiles.

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1320&Itemid=399

Customer Prints - oberoninc.com/images/WebDocs/Oberon_38-7X_Series_Retrofit_Doors.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

215

Page 216: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 38-7X-WAModel 107X Retrofit Door- Low-profile ABS dome

Category: Retrofit Doors for Oberon Enclosures

This locking retrofit door is designed to provide a convenient way to mount andsecure most vendors APs in model 1075, 1076, 1077, and 1078 Series APenclosures. Simply unlock door and remove three nuts from hinge to replacedoor. Impact resistant, white ABS plastic dome UL classified and virtuallytransparent to wireless signals. Simplify equipment replacement without liftingceiling tiles.

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1321&Itemid=399

Customer Prints - oberoninc.com/images/WebDocs/Oberon_38-7X_Series_Retrofit_Doors.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

216

Page 217: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 38-46-CCOAPRetrofit Door for Oberon 1046

Category: Retrofit Doors for Oberon Enclosures

This locking retrofit door is designed to provide a convenient way to mount andsecure wireless access points in 1046 Series AP enclosures. To remove the olddoor, simply unlock the door, open the door to a 90° angle, align the tabs of thedoor mount to the slots in the back-box hinge opening, and slide the doorforward. Simplify equipment replacement without lifting ceiling tiles.

Features & Benefits

Easily replace door to migrate to a new access point or antenna

Technical SpecificationsDesign: Locking, removable quick release door for Oberon Model 1046 ceiling enclosures for access points. Designed for Ciscoaccess points.Construction: White powder-coated steel door; aluminum access point bracketSize: 12.5 inches by 12.5 inches by 0.5 inches (318mm by 318mm by 13mm)

Measurements (Maximum values):

• Height: 12,5 in.• Width: 12.5 in.• Depth: 0.5 in.• Item Weight: N/A• Shipping Weight: N/A

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2814&Itemid=399

Customer Prints - oberoninc.com/images/WebDocs/Oberon_38-46_Series_Retrofit_Doors.pdf

Series Spec Sheet - oberoninc.com/images/WebDocs/Oberon_38-46_Series_Retrofit_Doors.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

217

Page 218: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 38-46-CCOAP3800Retrofit Door for Oberon 1046

Category: Retrofit Doors for Oberon Enclosures

This locking retrofit door is designed to provide a convenient way to mount andsecure wireless access points in 1046 Series AP enclosures. To remove the olddoor, simply unlock the door, open the door to a 90° angle, align the tabs of thedoor mount to the slots in the back-box hinge opening, and slide the doorforward. Simplify equipment replacement without lifting ceiling tiles.

Features & Benefits

Easily replace door to migrate to a new access point or antenna

Technical SpecificationsDesign: Locking, removable quick release door for Oberon Model 1046 ceiling enclosures for access points. Designed for Cisco3800 series access points.Construction: White powder-coated steel door; aluminum access point bracketSize: 12.5 inches by 12.5 inches by 0.5 inches (318mm by 318mm by 13mm)

Measurements (Maximum values):

• Height: 12.5 in.• Width: 12.5 in.• Depth: 0.5 in.• Item Weight: N/A• Shipping Weight: N/A

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2820&Itemid=399

Customer Prints - oberoninc.com/images/WebDocs/Oberon_38-46_Series_Retrofit_Doors.pdf

Series Spec Sheet - oberoninc.com/images/WebDocs/Oberon_38-46_Series_Retrofit_Doors.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

218

Page 219: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 38-47-CCOAPRetrofit Door for Oberon 1047

Category: Retrofit Doors for Oberon Enclosures

This locking retrofit door is designed to provide a convenient way to mount andsecure wireless access points in 1047 Series AP enclosures. To remove the olddoor, simply unlock the door, open the door to a 90° angle, align the tabs of thedoor mount to the slots in the back-box hinge opening, and slide the doorforward. Simplify equipment replacement without lifting ceiling tiles.

Features & BenefitsEasily replace door to migrate to a new access point or antenna

Technical SpecificationsDesign: Locking, removable quick release door for Oberon Model 1047 ceiling enclosures for access points. Designed for Ciscoaccess points.Construction: White powder-coated steel door; aluminum access point bracketSize: 18.5 inches by 18.5 inches by 0.5 inches (470mm by 470mm by 13mm)

Measurements (Maximum values):

• Height: 18.5 in.• Width: 18.5 in.• Depth: 0.5 in.• Item Weight: N/A• Shipping Weight: N/A

Documentation LinksSpec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2868&Itemid=399

Customer Prints - oberoninc.com/images/WebDocs/Oberon_38-47_Series_Retrofit_Doors.pdf

Series Spec Sheet - oberoninc.com/images/WebDocs/Oberon_38-47_Series_Retrofit_Doors.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

219

Page 220: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 38-47-CCOAP3800Retrofit Door for Oberon 1047

Category: Retrofit Doors for Oberon Enclosures

This locking retrofit door is designed to provide a convenient way to mount andsecure wireless access points in 1047 Series AP enclosures. To remove the olddoor, simply unlock the door, open the door to a 90° angle, align the tabs of thedoor mount to the slots in the back-box hinge opening, and slide the doorforward.. Simplify equipment replacement without lifting ceiling tiles.

Features & Benefits

Easily replace door to migrate to a new access point or antenna

Technical SpecificationsDesign: Locking, removable quick release door for Oberon Model 1047 ceiling enclosures for access points. Designed for Cisco3800 series access points.Construction: White powder-coated steel door; aluminum access point bracketSize: 18.5 inches by 18.5 inches by 0.5 inches (470mm by 470mm by 13mm)

Measurements (Maximum values):

• Height: 18.5 in.• Width: 18.5 in.• Depth: 0.5 in.• Item Weight: N/A• Shipping Weight: N/A

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2874&Itemid=399

Customer Prints - oberoninc.com/images/WebDocs/Oberon_38-47_Series_Retrofit_Doors.pdf

Series Spec Sheet - oberoninc.com/images/WebDocs/Oberon_38-47_Series_Retrofit_Doors.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

220

Page 221: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 38-47-DOMERetrofit Door for Oberon 1047

Category: Retrofit Doors for Oberon Enclosures

This locking retrofit door is designed to provide a convenient way to mount andsecure wireless access points in 1047 Series AP enclosures. To remove the olddoor, simply unlock the door, open the door to a 90° angle, align the tabs of thedoor mount to the slots in the back-box hinge opening, and slide the doorforward. Simplify equipment replacement without lifting ceiling tiles.

Features & Benefits

Easily replace door to migrate to a new access point or antenna

Technical SpecificationsDesign: Locking, removable quick release door for Oberon Model 1047 ceiling enclosures for access points. Designed for mostvendors’ access points.14” by 14” by 4” ABS plastic dome is large enough for most vendors’ access points with integrated antennas, and is transparentto wireless signalsConstruction: White powder-coated steel door; UL 94-5VA classified domeSize: 18.5 inches by 18.5 inches by 0.5 inches (470mm by 470mm by 13mm)

Measurements (Maximum values):

• Height: 18.5 in.• Width: 18.5 in.• Depth: 0.5 in.• Item Weight: N/A• Shipping Weight: N/A

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2895&Itemid=399

Customer Prints - oberoninc.com/images/WebDocs/Oberon_38-47_Series_Retrofit_Doors.pdf

Series Spec Sheet - oberoninc.com/images/WebDocs/Oberon_38-47_Series_Retrofit_Doors.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

221

Page 222: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 38-47-HLARetrofit Door for Oberon 1047

Category: Retrofit Doors for Oberon Enclosures

This locking retrofit door is designed to provide a convenient way to mount andsecure wireless access points in 1047 Series AP enclosures. To remove the olddoor, simply unlock the door, open the door to a 90° angle, align the tabs of thedoor mount to the slots in the back-box hinge opening, and slide the doorforward. Simplify equipment replacement without lifting ceiling tiles.

Features & Benefits

Easily replace door to migrate to a new access point or antenna

Technical SpecificationsDesign: Locking, removable quick release door for Oberon Model 1047 ceiling enclosures for access points. Designed for CiscoHLA antenna and access points.Construction: White powder-coated steel door; aluminum access point bracketSize: 18.5 inches by 18.5 inches by 0.5 inches (470mm by 470mm by 13mm)

Measurements (Maximum values):

• Height: 18.5 in.• Width: 18.5 in.• Depth: 0.5 in.• Item Weight: N/A• Shipping Weight: N/A

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2880&Itemid=399

Customer Prints - oberoninc.com/images/WebDocs/Oberon_38-47_Series_Retrofit_Doors.pdf

Series Spec Sheet - oberoninc.com/images/WebDocs/Oberon_38-47_Series_Retrofit_Doors.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

222

Page 223: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 38-47-LPDOMERetrofit Door for Oberon 1047

Category: Retrofit Doors for Oberon Enclosures

This locking retrofit door is designed to provide a convenient way to mount andsecure wireless access points in 1047 Series AP enclosures. To remove the olddoor, simply unlock the door, open the door to a 90° angle, align the tabs of thedoor mount to the slots in the back-box hinge opening, and slide the doorforward. Simplify equipment replacement without lifting ceiling tiles.

Features & Benefits

Easily replace door to migrate to a new access point or antenna

Technical SpecificationsDesign: Locking, removable quick release door for Oberon Model 1047 ceiling enclosures for access points. Designed for mostvendors’ access points.13” by 13” by 2” ABS plastic dome is large enough for most vendors’ access points with integrated antennas, and is transparentto wireless signalsConstruction: White powder-coated steel door; UL 94-5VA classified domeSize: 18.5 inches by 18.5 inches by 0.5 inches (470mm by 470mm by 13mm)

Measurements (Maximum values):

• Height: 18.5 in.• Width: 18.5 in.• Depth: 0.5 in.• Item Weight: N/A• Shipping Weight: N/A

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2889&Itemid=399

Customer Prints - oberoninc.com/images/WebDocs/Oberon_38-47_Series_Retrofit_Doors.pdf

Series Spec Sheet - oberoninc.com/images/WebDocs/Oberon_38-47_Series_Retrofit_Doors.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

223

Page 224: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 38-52-00Retrofit door for Oberon 1052 Series

Category: Retrofit Doors for Oberon Enclosures

Locking, removable fully-hinged door for Oberon Model 1052 ceiling enclosuresfor access points. Designed for most vendors’ access points with connectors forexternal antenna.

Technical Specifications

Design: Locking, removable fully-hinged door for Oberon Model 1052 ceiling enclosures for access points. Designed for mostvendors’ access points with connectors for external antenna.Construction: White powder-coated steel door; aluminum access point bracketSize: 12.5 inches by 12.5 inches by 0.5 inches (318mm by 318mm by 13mm)

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2791&Itemid=399

Customer Prints - oberoninc.com/images/WebDocs/Oberon_38-52_Series_Retrofit_Doors.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

224

Page 225: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 38-52-CCOANTModel 1052 Retrofit Door- Cisco Antenna door mount

Category: Retrofit Doors for Oberon Enclosures

This locking retrofit door is designed to provide a convenient way to mount andsecure Cisco Antennas in 1051 and 1052 Series AP enclosures. Simply unlockdoor and remove three nuts from hinge to replace door. Simplify equipmentreplacement without lifting ceiling tiles.

Features & BenefitsSimplifies compliance with industry standards and guidelines for Retail (PCI), Healthcare (ICRA), and Goverment deploymentsSecure, Convenient, Aesthetic

Technical SpecificationsAdaptor door designed to mount the Cisco 1260/3500e/3600e series 802.11n wireless access point into existing Oberon Model1052-00 ceiling tile enclosuresWith adaptor door properly installed, the assembly is UL listed and designed to meet NEC300-22 and 300-23 for installations in theair handling space, OSHPD approved OPM-0110-13-10 (.pdf)Door mounting features for Cisco P/N AIR-ANT2430V-R and AIR-ANT5140V-R antennas onlyConstruction: Textured white powder-coated steel, 14 ga. doorFully hinged locking door, keyed alike. Door can be replaced to migrate to new access points.Adaptor door is attached to enclosure with (3) nuts

IncludesAdaptor doorAssembly mount bracket and nutsInstallation Instructions

Documentation LinksSpec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1285&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model38-52-CCOANT_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Oberon_38-52_Series_Retrofit_Doors.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

225

Page 226: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 38-52-CCOAPModel 1052 Retrofit Door- Cisco APs

Category: Retrofit Doors for Oberon Enclosures

This locking retrofit door is designed to provide a convenient way to mount andsecure Cisco APs in 1051 and 1052 Series AP enclosures. Simply unlock door andremove three nuts from hinge to replace door. Simplify equipment replacementwithout lifting ceiling tiles.

Technical Specifications

Design: Locking, removable fully-hinged door for Oberon Model 1052 ceiling enclosures for AP. Designed for Cisco 2600, 2700,3500, 3600, 3700 seriesConstruction: White powder-coated steel door; aluminum AP bracketSize: 12.5 inches by 12.5 inches by 0.5 inches (318mm by 318mm by 13mm)

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1282&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model38-52-CCOAP_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Oberon_38-52_Series_Retrofit_Doors.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

226

Page 227: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 38-52-CCOAP3800Model 1052 Retrofit Door- Cisco APs

Category: Retrofit Doors for Oberon Enclosures

This locking retrofit door is designed to provide a convenient way to mount andsecure Cisco APs in 1051 and 1052 Series AP enclosures. Simply unlock door andremove three nuts from hinge to replace door. Simplify equipment replacementwithout lifting ceiling tiles.

Technical Specifications

Design: Locking, removable fully-hinged door for Oberon Model 1052 ceiling enclosures for AP. Designed for Cisco 2800 and 3800seriesConstruction: White powder-coated steel door; aluminum AP bracketSize: 12.5 inches by 12.5 inches by 0.5 inches (318mm by 318mm by 13mm)

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=3310&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model38-52-CCOAP_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Oberon_38-52_Series_Retrofit_Doors.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

227

Page 228: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 38-52-DOMEModel 1052 Retrofit Door- 4" dia. White ABS dome

Category: Retrofit Doors for Oberon Enclosures

This locking retrofit door is designed to provide a convenient way to mount andsecure most vendors APs with non-detachable antennas in model 1051 and 1052Series AP enclosures. Simply unlock door and remove three nuts from hinge toreplace door. Impact resistant, 9” diameter, white ABS plastic dome UL classifiedand virtually transparent to wireless signals. Simplify equipment replacementwithout lifting ceiling tiles.

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1315&Itemid=399

Customer Prints - oberoninc.com/images/WebDocs/Oberon_38-52_Series_Retrofit_Doors.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

228

Page 229: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 39-1008-SPKRMNTU-Bolt bracket assembly for the Model 1008/1009 series

Category: Enclosure Accessories

The Model 39-1008-SPKRMNT is a U-bolt bracket assembly used to mountWireless Access Points to a 1-3/8" speaker stand (not included,) using OberonModel 1008 and 1009 right-anglebracket series (not included.)

Features & Benefits

Fits standard 1-3/8" Speaker Stands

Technical SpecificationsConstruction: 14 ga. powered coated bracketSize: 7” x 3.5” x 0.075” deep1-7/16" Zinc Plated Clamping U-Bolt

Measurements (Maximum values):

• Height: 7 in.• Width: 3.5 in.• Depth: 0.075 in.• Item Weight: 1 lbs.• Shipping Weight: 2 lbs.

Includes(1) U-Bolt Mounting Bracket(1) Clamping U-Bolt(2) #1/4-20 x 3/8" ScrewInstallation Instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=3127&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model39-1008-SPKRMNT_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model39-1008-SPKRMNT_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

229

Page 230: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 39-1015-PLATEModel 1015 Metal Back Plate

Category: Enclosure Accessories

This ceiling plate fastens to Oberon's Model 1015 unit, inside or out, and allowsthe installer to hang the enclosure with Y-Toggles or a rigid conduit flange.

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2000&Itemid=399

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

230

Page 231: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 39-1016-ANTPLATEArticulating Antenna Mount for Oberon Model 1016 Series

Category: Enclosure Accessories

The Model 39-1016-ANTPLATE is an antenna bracket for the Cisco AIR-ANT2566P4W-R in the Model 1016 series.

Features & Benefits

Articulating antenna bracketKeyhole slots and other mounting features for Cisco Access Points

Technical SpecificationsGalvanized Steel Antenna Bracket and Mounting PlateSize: 16” x 11" x 2” deepShipping Weight: 5 lbs.

Measurements (Maximum values):

• Height: 16 in.• Width: 11 in.• Depth: 2 in.• Item Weight: N/A• Shipping Weight: 5 lbs.

Includes(1) Antenna Bracket(1) Mounting Plate(6) #8-32 x 3/8 Screws(4) #8-32 x 1/4 Screws(4) #6 Tapping ScrewsInstallation Instructions

Available Accessories39-1016-SPKRMNT - Mounting bracket assembly for the Model 1016 series

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=3051&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Oberon_Model_39-1016-ANTPLATE_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Oberon_Model_39-1016-ANTPLATE_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf231

Page 232: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 39-1016-SPKRMNTMounting bracket assembly for the Model 1016 series

Category: Enclosure Accessories

Features & Benefits

Fits standard 1-3/8" Speaker Stands

Technical SpecificationsConstruction: 16 ga. galvanized bracketSize: 10.87” x 0.65” x 0.60” deep1-7/16" Zinc Plated Clamping U-Bolt

Measurements (Maximum values):

• Height: 10.18 in.• Width: 0.65 in.• Depth: 0.60 in.• Item Weight: 2 lbs.• Shipping Weight: 3 lbs.

Includes(2) Speaker Mount Bracket(2) Clamping U-Bolt(4) #8-32 x 1/2" ScrewInstallation Instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=3094&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model39-1016-SPKRMNT_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Model39-1016-SPKRMNT_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

232

Page 233: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 39-1020-PMKPole Mount Kit for Oberon Model 1020-RAB

Category: Enclosure Accessories

Features & Benefits

Adjustable worm gear clamps for square and round poles with diameters from 5" to 9"Designed to mount Oberon Model 1020-RAB vertically and horizontallyOpening for cable egress

Technical SpecificationsLight gray powder-coated aluminum with stainless steel hardwareSize: 11” x 4" x 1.9” deepShipping Weight: 5 lbs.

Measurements (Maximum values):

• Height: 11 in.• Width: 4 in.• Depth: 1.9 in.• Item Weight: N/A• Shipping Weight: 5 lbs.

Includes(1) Pole Mount Bracket(2) Worm gear clamps(4) #10-32 stainless steel screws(1) Installation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=3045&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Oberon_Model_39-1020-PMK_Installation_Instructions.pdf

Customer Prints - oberoninc.com/images/WebDocs/Oberon_Model_39-1020-PMK_Customer_Print.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

233

Page 234: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 39-1790-INTERLOCKPoE Interlock Switch - Disables AP on door open

Category: Enclosure Accessories

Power over Ethernet Interlock Switch (PoE ILS): The 33-1790 PoE ILS is anoptional security component for Oberon enclosures. Any unauthorized enclosureopening can be sensed and logged by the wireless system using the PoE ILS.When installed in-line with a PoE Ethernet connection to a WiFi Access Point, thePoE ILS will disrupt the incoming power to the AP when the enclosure door orlock is opened. Enterprise class access points will log this event, as will wirelesscontrollers.

Technical SpecificationsSpecifications:

Designed to be installed in Oberon enclosuresOne input RJ45 connector and one output RJ45 connectorA customer supplied CAT 5/6 jumper required between the PoE ILS output RJ45 connector and the wireless access pointUL approved

Model 1790 Includes:

(1) PoE ILS PCB assemblyFour (4) mounting screwsInstallation instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=1349&Itemid=399

Installation Instructions - oberoninc.com/images/WebDocs/Model1790-00_Installation_Instructions.pdf

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

234

Page 235: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Model 39-HLA-PLATEBracket Accessory for Cisco Hyperlocation Antenna

Category: Enclosure Accessories

This accessory is designed to permit the Cisco access point and HyperlocationAntenna to be mounted on Oberon’s 1008, 1009, 1010, and 1011 right-anglebrackets. These right-anglebrackets mount and secure the AP and antenna in the preferred horizontalorientation. The 39-HLA-PLATE attaches directly to the Oberon right-anglebracket and permits the larger Cisco AP and antenna to be mounted in anydirection, as required for proper angle of arrival performance.

Features & Benefits

Attaches to Oberon 1008, 1009, 1010, 1011 right-angle bracketsUpgrade previously installed right-angle brackets for AP and hyperlocation antennaMount AP and Hyperlocation antenna in preferred horizontal orientation on the wallMount AP and Hyper location antenna in four directions

Technical SpecificationsConstruction: Galvanized steel

IncludesMounting plateInstallation hardwareInstallation Instructions

Documentation Links Spec Sheet - oberoninc.com/index.php?option=com_content&view=article&id=2246&Itemid=399

SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS -

http://oberoninc.com/images/WebDocs/SECTION 27_21_33 DATA COMMUNICATIONS WIRELESS ACCESS POINTS.pdf

235

Page 236: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

How to Buy Oberon Products

Oberon products are distributed by these industry leading datacomm product distributors. Please contact your local branch for price and availability

Accu-Tech

www.accu-tech.com

eAccu-Tech

www.eaccu-tech.com

Anixter

www.anixter.com

Oberon products

Beach Wire & Cable

www.beachwire.com

Graybar Electric Company,

Inc.

ShopGraybar

Jenne, Inc.

www.jenne.com

Wesco (Communication

Supply Corp)

www.wescodist.com

www.gocsc.com

Wise Components Datacomtools.com

Custom Access Point Enclosures

Oberon offers one of the industries broadest ranges of wireless access point enclosures and mounting solutions to meet your wireless WiFi deployment needs. This means that you will probably find what you need in this catalog; however, if you have an application where you need a customized solution, Oberon can design enclosures and mounting solutions for practically any network connection requirement. Using our existing design database, Oberon can quickly and economically design WiFi access point and other wireless equipment mounts and enclosures which accommodate most manufacturers’ products. Contact your Oberon representative for details.

Aesthetically pleasing, locking, plenum-rated ceiling mounts and enclosures for enterprise WiFi access points

Right-angle, surface mount and recess wall mounts for WiFi access points Vandal, tamper, and theft-resistant indoor and outdoor wireless equipment enclosures Vanity covers for WiFi access points

Architecturally benign or discrete wireless enclosures Indoor/outdoor NEMA 4/3R enclosures

236

Page 237: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Appendix A – Industry Compliance Assurance

A well-designed network addresses the physical security of all components. In many industries, the need to ensure continual and secure operation of wireless networks has led to the development of guidelines and regulations regarding the proper placement of networking equipment in a variety of physical environments.

Government, Retail, and Healthcare are three such industries. All deal with sensitive, mission-critical information that must be secured from tampering and theft. Additionally, Healthcare environments must take infection control into account, complicating networks where reaching physical components can mean intrusion into air-handling spaces.

Enclosures for wireless equipment address these needs in a variety of ways:

Secure networking components behind locking doors, away from tampering and theft attempts

Attach securely to building structures for greater security and physical protection

Accomplish moves, adds, and changes quickly, allowing authorized personnel to work below the back-

box with no need to intrude on the air-handling space

Lock access points into their best placement for ideal radiation patterns, ensuring that you retain full

control over placement

For Oberon enclosures, security and convenience go hand-in-hand. Imagine making moves, adds, and changes in minutes simply by unlocking the enclosure door for easy access. Place your network equipment where you want it, and rest assured that it won't move or be removed.

SIMPLIFY PCI-DSS COMPLIANCE Payment Card Industry Data Security Standard (PCI-DSS) requirement 9.1.3 states that the operator must "restrict physical access to wireless access points, gateways, and handheld devices” and “verify that physical access to wireless access points, gateways, handheld devices, networking/communications hardware, and telecommunication lines is appropriately restricted."

SAVE TIME & MONEY: SIMPLIFY ICRA PROCEDURES In Healthcare, The Joint Commission on Hospital Accreditation has established procedures for mitigating the spread of infectious disease and contamination. Infection control risk assessment (ICRA) will have a serious impact on cabling installation, moves, adds, and changes.

Oberon enclosures provide access to wireless LAN access points and telecom equipment without entering the air-handling “plenum” space, simplifying compliance with ICRA guidelines. In addition to providing added safety, convenience, and the security of a locked door, Oberon enclosures also help installations meet the National Electric Code (N.E.C.) article 300.22 requirements for installing unlisted equipment above a suspended ceiling.

Telecom enclosures enhance long-term growth options with flexible cabling, allowing easy future changes and Bringing Bandwidth Closer to the User™.

GOVERNMENT NETWORK DEPLOYMENTS: SECURITY FIRST Government / DoD– Directive 8100.2 mandates FIPS 140-2 compliance wherein FIPS 140-2 paragraph 4.5 requires "physical security mechanisms" to be applied.

Oberon enclosures feature locking doors and are secured to building structure, providing the physical security you need while remaining virtually transparent to wireless signals for optimum performance.

237

Page 238: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Appendix B – Oberon’s National Electric Code paragraphs Compliance Statement and Underwriters Laboratories (UL™) Considerations when using Oberon’s Wireless LAN Access Point Mounting Solutions Manufacturers’ Statement of Compliance with NFPA 70, National Electric Code Oberon’s wireless access point enclosures are constructed entirely of non-flammable steel and aluminum in the plenum space. Therefore, they are compliant with the following NFPA 70 National Electric Code paragraphs, for wiring and equipment in Plenum Space: 300-21 Spread of Fire or Products of Combustion 300-22 Wiring in Ducts, Plenums and Other Air Handling Spaces, paragraphs (a), (b), (c), and (d) For Compliance with National Electric Code paragraphs, Wireless access point enclosures should be supported according to the following paragraph: 300.11 Securing and Supporting

(A) Secured in Place. Raceways, cable assemblies, boxes, cabinets, and fittings shall be securely fastened in place. Support wires that do not provide secure support shall not be permitted as the sole support. Support wires and associated fittings that provide secure support and that are installed in addition to the ceiling grid support wires shall be permitted as the sole support. Where independent support wires are used, they shall be secured at both ends. Cables and raceways shall not be supported by ceiling grids.

238

Page 239: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Appendix C – Warranty

Terms and Conditions Sale of Equipment – Seller agrees to sell the equipment specified on any quotation, sales order, invoice, or packing slip to Buyer upon the terms and conditions stated below. Shipment – Unless special arrangements are made, ownership of the goods and risk of damage/loss passes to Buyer when the freight carrier picks them up from Seller, and Buyer is responsible for filing any freight claims for damage or loss. If an item is received with freight damage, it is very important for the Buyer to note "Damaged Freight” on the carrier's bill before signing it. Freight and Other Charges – Freight charges are prepaid by Seller and added to Buyer's invoice plus a service/handling charge. Sales tax will be charged as required by law. Credit and Payment Terms – Standard credit terms are Net 30. Oberon accepts company checks, certified checks, Visa or MasterCard. Payments on past due invoices will be subject to a "Late Charge" in the amount of 1½% per month.

Can products be returned? Yes, HOWEVER, there is a 20% re-stocking fee for all products. Special orders, custom configured, modified, or cut to length products are not returnable. After 90 days, no returns or exchanges will be accepted. Under no circumstances will Oberon be liable for any incidental, consequential, special or exemplary damages. Customer shall insure return shipments for value of product returned. Customer shall be responsible for legal and other fees associated with collection of payments to Oberon which are past due. Please contact Oberon for a RMA number for your return. Any items returned to Oberon without a RMA will be refused and returned to the Customer.

Limited Warranty Limited Warranty – Equipment manufactured by Seller -Seller warrants to Buyer that the equipment will be free of defects in materials and workmanship for a period of one (1) year from the date of shipment. This warranty shall not apply to any equipment, which is misused, or for any damage to the equipment resulting from improper installation or operation, vandalism, acts of God, or any other cause beyond reasonable control of the seller. This warranty shall be void if the equipment has been altered, tampered with, or repaired by a party other than the Seller or its authorized representative. In the event of equipment failure within the warranty period, Seller will repair or replace the defective equipment, at its option, provided that Buyer notifies Seller and obtains a RMA number prior to returning the equipment to Seller. Defective equipment must be returned, shipping prepaid, to the Seller's specified address. The warranty on repaired or replaced equipment will be the balance of the original Equipment Warranty. This Warranty Is In Lieu Of All Other Warranties, Express or Implied, Including, Without Limitation, Statutory Warranties or Warranty of Merchantability or Fitness for a Particular Purpose. Seller's sole liability and Buyer's sole remedy hereunder will be repair of replacement of the Equipment as provided in this agreement. Other Equipment -Seller will pass through to Buyer all original Manufacturers' Warranties that may apply to the equipment. Seller may, at its option, process warranty requests by the Buyer to the Original Manufacturer, or refer the Buyer to the Original Manufacturer. Seller is not responsible for any warranty-related issues. OBERON HEREBY EXPRESSELY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION THE WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE AND ALSO DISCLAIMS AND EXCLUDES ALL CONSEQUENTIAL AND INCIDENTAL DAMAGES FOR BREACH OF CONTRACT OR OTHERWISE.

239

Page 240: Solutions for Cisco Access Points oberoninc2017/06/25  · Solutions for Cisco Access Points oberoninc.com Oberon, Inc. | 1315 S. Allen Street | State College, PA 16801 | Phone (877)

Is Your Wireless Network

Compliant with Industry

Guidelines?

Visit oberoninc.com/by-industry or ask your Oberon representative for more information about selecting

the right enclosure for your installation.

Healthcare

Government

Education

Hospitality

Retail

Architecture

National Electric Code (NEC)

In addition to providing added safety, convenience, and the security of a locked door, Oberon enclosures also help installations meet the National Electric Code (N.E.C.) article 300.22 requirements for installing equipment above a suspended ceiling.

Payment Card Industry Data Security Standard (PCI-DSS)

Payment Card Industry Data Security Standard (PCI-DSS) requirement 9.1.3 states that the operator must “restrict physical access to wireless access points, gateways, and handheld devices,” and “verify that physical access to wireless access points, gateways, handheld devices, networking/communications hardware, and telecommunication lines is appropriately restricted.”

Federal Information Processing Standard (FIPS)

Government/DoD Directive 8100.2 mandates FIPS 140-2 compliance, wherein FIPS 140-2 paragraph4.5 requires “physical security mechanisms” to be applied. Oberon enclosures feature locking doors and are secured to the building structure, providing physical security while remaining virtually transparent to wireless signals for optimum performance.

Infection Control Risk Assessment (ICRA)

The Joint Commission on Hospital Accreditation has established procedures for mitigating the spread of infectious disease and contamination. Infection Control Risk Assessment (ICRA) will have a serious impact on cabling installation, moves, adds, and changes. Oberon enclosures provide access to wireless LAN access points and telecom equipment without entering the air-handling space, a key factor in risk mitigation.

Health Insurance Portability and Accountability Act (HIPAA) Requirements

§ 164.310 Physical safeguards. A coveredentity must, in accordance with 164.306: (a)(1) Standard: Facility access controls. Implement policies and procedures to limit physical access to its electronic information systems and the facility or facilities in which they are housed, while ensuring that properly authorized access is allowed.