sorces of errors in a filled system thermometer

15
Presented By : Tejas Atyam 4 th sem Production

Upload: tejas-atyam

Post on 02-Jul-2015

532 views

Category:

Engineering


13 download

DESCRIPTION

another ppt for a class presentation . I admit it is a bit incomplete but this is all I got as a topic for explanation . I hope you guys gain from it !

TRANSCRIPT

Page 1: Sorces of errors in a filled system thermometer

Presented By :

Tejas Atyam

4th sem Production

Page 2: Sorces of errors in a filled system thermometer

Common Sources of Errors are:

Ambient temperature Effect

Head or Elevation Efffect

Barometric Effect

Immersion Effect

Radiation Effect

Page 3: Sorces of errors in a filled system thermometer

The effect taking place due to the

exposure of the bourdan tube and the

capillary tube to the surroundings .

Being exposed to the surroundings causes

them to be subjected to variable temp.

widely different to that of the bulb .

Page 4: Sorces of errors in a filled system thermometer

Using Large Bulb :

From the equation we can clearly see that

the use of a larger bulb will reduce the

error

Case Compensation :

A bimetallic strip or secondary bourdan

tube is used to counter the deflection in

the main bourdan tube in the opposite

direction .

Page 5: Sorces of errors in a filled system thermometer

Full Compensation :The only new difference id that even a capillary tube has been attached to counter the effects .

Using Self Compensating Capillary :In this case the cross section of the capillary is made into a annulus which has a special alloy wire in its whole length to counter the capillary expansion.

Page 6: Sorces of errors in a filled system thermometer
Page 7: Sorces of errors in a filled system thermometer
Page 8: Sorces of errors in a filled system thermometer
Page 9: Sorces of errors in a filled system thermometer
Page 10: Sorces of errors in a filled system thermometer

This is the error caused due the elevation

of the bulb from the level of the bourdan

tube . Due to the difference in height a

pressure head is created which causes

error in the temperature reading .

Page 11: Sorces of errors in a filled system thermometer
Page 12: Sorces of errors in a filled system thermometer

The tip travel of bourdon tube is due to

pressure difference between atmosphere

and filled system pressure . So if there is

any variation in atmosphere pressure from

designed pressure , the bourdon tip travels

and causes an error reading .

The equation shown by me is used to

calculate the error .

Page 13: Sorces of errors in a filled system thermometer

This error is caused to the improper

immersion or insulation of head of bulb .

Page 14: Sorces of errors in a filled system thermometer

This error occurs due to temperature difference between the bulb and solid bodies around it .

Dip Effect : In case of a metallic bulb of mercury filled system, the metallic bulb expands before expansion of mercury , hence volume of bulb is increased and pressure reduces . So in short respose of thermometer is slowed down .

Page 15: Sorces of errors in a filled system thermometer