soyal ar727h mu en

50
AR-727H User’s Guide Version: 4.2 May 13, 2004

Upload: jesus-alberto-naranjo

Post on 04-Mar-2015

464 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: Soyal Ar727h Mu En

AR-727H

User’s Guide

Version: 4.2

May 13, 2004

Page 2: Soyal Ar727h Mu En

1

1.Add - Card ID 2.Add - RF-learn3.Suspend - Addr4.Suspend – ID #5.Delete - Addr 6.Delete – ID# 7.Recover - Addr8.Recover –ID #9.Antipass Group

1.Node ID 2.Auto Open Zone

3.Door Relay Tm 4.Door Close Tm 5.Alarm Relay Tm6.Alarm Delay Tm7.Arming Delay Tm8.Arming PWD 9.Arming Pulse

1.Password 2.Access Mode3.Extend Options4.Single Floor5.Multi Floors

1.Auto Relock 2.Egress(R.T.E.) 3.Attendance 4.Master Node 5.Force Open… 6.Close & Stop 7.Anti-passback 8.Duress Code 9.Factory Reset

1.Add/Delete

2.User Setting

3.Parameters(1)

4.Parameters(2)

5.Tools

6.Quit

7.Quit & Arming

1.Language 2.Master Code 3.Master Range 4.Terminal Port 5.AR721R32 Port 6.Open TimeZone 7.Informations 8.Clock Setting 9.Control Mode 10.View Events

Function Menu

Page 3: Soyal Ar727h Mu En

2

Table of Contents

Page

1. Main Feature --------------------------------- 4 2. Control Mode --------------------------------- 5 3. Notice --------------------------------- 7 How to know card ID of user address?---------------------- 7 LCD display show card ID except user address (ex. 00005) when the user flash card? ---------------------- 8 How to know how many users in the system now?------- 8 How to start/suspend (auto open zone)?-------------------- 8 How to disarming? --------------------------------- 9 How to restore master code to the factory default?------ 9 How to reset all parameter to the factory default?-------- 9 How to set the time on AR-727H? ------------------------- 10 How to check the historical records?------------------------- 11 4. Front Panel & Functions --------------------------------- 12 5. Mode 4 / 8 / 9 --------------------------------- 14

5.1 Card Editing --------------------------------- 14 5.2 Access Mode --------------------------------- 15 5.3 Duress function --------------------------------- 18 5.4 Force on/off code --------------------------------- 19

6 Mode 6 --------------------------------- 21 6.1 Card editing --------------------------------- 21 6.2 Access mode --------------------------------- 21

7 Quick Guide --------------------------------- 22 8 Function description --------------------------------- 23 9 Special designed --------------------------------- 25

9.1 Connecting one AR-727H with 2 AR-661U for Anti-pass-back --------------------------------- 25

9.2 How AR-727 connects with a weigand reader (AR-721K, AR-721U, AR-661U) and to apply to anti-pass back --------------------------------- 26 9.3 How to set multi AR-727H connects with a net controller and to apply to anti-pass-back-------------- 26

Page 4: Soyal Ar727h Mu En

3

9.4 How to setting the weigand reader (AR-721U, AR-721K, AR-661U) and AR-727H at the same net controller to apply to the anti-pass-back -------------------------------- 26 9.5 How to set that user arrive single floor or multi-floor28 9.6 How to set AR-401RO16 parameter------------------- 29

10 Installation -------------------------------- 31 10.1 Step -------------------------------- 31 10.2 Installation Notice -------------------------------- 32

11 Wiring -------------------------------- 34 12 Installation diagram -------------------------------- 36

12.1 Magnetic lock -------------------------------- 36 12.2 Electric bolt lock -------------------------------- 37 12.3 Electric strike -------------------------------- 38 12.4 Magnetic door contacts and alarm system ---------- 39 12.5 Wiegand reader -------------------------------- 40 12.6 Networking installation -------------------------------- 42 12.6.1 two set of AR-716EV2 parallel installation-- 42 12.6.2 AR-716EV2, AR-829E and AR-727H

parallel installation-------------------------------- 43 12.7 Lift controller AR-401RO16 installation--------------- 44 12.8 AR-727H & AR-801CM & PC installation------------ 45

13 Troubleshooting -------------------------------- 46 14 Return of Products -------------------------------- 47 15 Warranty -------------------------------- 47 16 Transponder Record Table -------------------------------- 48 17 Specification -------------------------------- 49

Page 5: Soyal Ar727h Mu En

4

1. Main Features With waterproof, could be installed outside.

Special feature for stand-alone use:

◎ Keep last 20 transactions

◎ Editable 2 time zone for door release purpose

◎ Controller needless anti-pass back:: AR-727H supports anti-pass back with its external reader.

Master Cards range assignable.

Clear and big LCD panel with 4 line messages. (128 * 64 graphic)

One RS-485 Port supported for networking.

Built-in one Door sensor and Arming on/off input.

Support with keypad locks immd & all cards entrance allowance before cards editing finished.

Support remote operation to relays on networking controller AR-716E / AR-727E via Force on/off code.

Support with Auto-relock automatically and keypad locked if continuous wrong code inputted.

Control mode, card capacity and card type assignable by user directly.

Built-in a proximity reader, a external wiegand reader port and IC card reader (optional).

Auto-discriminating between stand-alone & networking system, AR-727H could connect with controller AR-716E, AR-727E to have multi-door anti-pass back.

Alarm function available. (Tamper, Force entrance, door open too long)

Universal serial port supported for LED display, printer, lift controller, etc

Page 6: Soyal Ar727h Mu En

5

2. Control Mode

AR-727H MODE 4

Stand-aloneMODE 6

Stand-aloneMODE 8

Stand-aloneMODE 9

Stand-aloneNetworking

Card user

Capacity 1000 63200 1000 1000

Depend on

Controller

Access

Mode

Card only

Card & PINUser nbr. & PIN

Card onlyCard only

Card & PINPIN only

Card only

Card & PINUser nbr. & PIN

Depend on

Anti-pass

Back Single door × Single door x

Multi-door

anti-pass back

(16 doors)

Control Mode in

Networking

Mode 4 × Mode 8 Mode 9 Mode 4

Or Mode 8

Note WG32 WG 16 WG32 WG32 WG32

Lift control 32 stop

600 card users

× 32 stop

600 card user

x 32 stop

600 card users

Now, 727H CPU version 3.7 was added a new control mode- Mode 9.

Version 4.2 – mode 9 directly connect to PC through AR-801CM converter for only Time and Attendance function.

Special feature for stand-alone use: (Version 3.7 UP) ◎ Under Mode 9, keep 480 transactions ◎ Not support Anti-pass-back and lift control. ◎ 1000 user cards capacity. Can connect to PC through AR-801CM for only Time and

Attendance function. (Version 4.2 UP) ◎ Under Mode 9, keep 480 transactions ◎ 1000 user cards capacity. ◎ Not support Anti-pass-back, lift control, Time zone and Door group.

Page 7: Soyal Ar727h Mu En

6

◎ Please note transaction record just show normal access Message, without the message from invalid card and Push button.

How to set Mode 4 ,Mode 6 , Mode 8 and Mode 9:

Step1: * + 1 2 3 4 5 6 + # enter the “FUNCTION MENU”

Step2: Tool / control mode (command:59) 1:M4 2:M6 3:M8 4:M9, input Mode value. tags format—1:EM 2:SOYAL, input card value.

Note: Changing control mode “from Mode 6 to Mode 4” or “from Mode 4

to Mode 6”, it is necessary to delete all card user data first.

Depend on controller: For example, controller AR-716EV2 has 15,000 card users capacity.

Lift control: For 600 card users, everyone could be assigned for single floor or multi-floor access.

Page 8: Soyal Ar727h Mu En

7

3. Notice

Keep AR-727H away from the followings: Keep away from magnets or any magnetized items. Do not apply strong shock to 727H

After flash master card and press F1 F2 F3 F4 or # within 2 seconds can enter the “FUNCTION MENU”. Master Cards range assignable. Default value: user address 00000 – 00004.

Each card has 10 digits code, including Site code (5 digits) and Card code (5 digits). Neither the Site Code nor the Card Code numbers can be 0.

After card editing finished, Site Code and Card Code is not important anymore. System will require a USER ADDRESS instead.

User can request to exit through the controlled door without using transponder (and without causing an alarm condition), by pressing an exit button. This will operate the door relay for the programmed door relay release time & stop alarm.

How to know card ID of user address? (For example: which card ID do we want to know user address 00003) Step1: * + 1 2 3 4 5 6 + #

enter the “FUNCTION MENU” Step2: Add/Delete (command 1) Step3: Add / Card ID (command 1) Step4: Enter user address 00003, then you will see card ID.

Page 9: Soyal Ar727h Mu En

8

LCD display show card ID except user address (ex. 00005) when the user flash card? How to do? Step1: * + 1 2 3 4 5 6 + #

enter the “FUNCTION MENU” Step2: Parameters (1) (command 3) Step3: Node ID (command 1) Step4: Set Node ID Step5: Then, the system will ask if show card ID? 1. No 2. WG 3. ABA 4. HEX Cur.: 1 Step6: If select 2. WG, for example as follows: User address 00005 for card ID 00020:25000 When user flash card, LCD display will show both user address 00005 and card ID 00020:25000. Note that CPU version must be at least 4.1 or up.

How to know how many users in the system now? (Not including suspend card) Step1: * + 1 2 3 4 5 6 + #

enter the “FUNCTION MENU” Step2: Tools (command 5) Step3: Informations (command 7) AR-727H Ver 3.4 Users: 00010 (There are already 10 users in the system)

How to start/suspend (auto open zone)? Step1: main manual Step2: tools (command 5) Step3: setting Open Time Zone (command 6) Step4: come back to main manual Step5: Parameters (1) (command 3) Step6: start Auto open zone function (command 2) Step7: Yes / No Note: The electronic lock would be locked until first one flash

Page 10: Soyal Ar727h Mu En

9

card on the reader when the system enter auto open time zone. And electronic lock will be locked that sensor feels door closed when system exit auto open time zone.

How to disarming? (1) User can be disarming by normal access mode once

violating anti-pass-back resulting in alarm. (2) User can be disarming by valid card when alarm happen. (3) * + 1 2 3 4 5 6 + #

enter the “FUNCTION MENU” Step1: main manual Step2: Parameters (2) (command 4) Step3: Close Door Stop Alarm (command 6), then enter 1: YES.

How to restore master code to the factory default (123456)?

If the master code is forgotten it can be restored to the factory

default (123456). Remove the AR-727H from the mounting

plate, disconnect power, remove AR-727H CPU, install

AR-727H-CLE CPU, and restore power about 10 seconds.

Then disconnect power, remove AR-727H-LCE CPU, install

AR-727H CPU, and restore power.

How to reset all parameter to the factory default?

Step1: * + 1 2 3 4 5 6 + # enter the “FUNCTION MENU”

Step2: Parameters(2) (command 4)

Step3: Factory Reset (command 9)

Page 11: Soyal Ar727h Mu En

10

Then, LCD display will show “Initial System……” message to

reset all parameter to factory default.

Note that CPU version must be at least 3.8 or up.

How to set the time on AR-727H?

Step1: * + 1 2 3 4 5 6 + #

enter the “FUNCTION MENU” Step2: Tools (command 5) Step3: Clock Setting (command 8) Step4: Input Date&Time YyMmDdHhMmSs

Page 12: Soyal Ar727h Mu En

11

How to check the historical records? (1) Press * + 1 2 3 4 5 6 + # enter the “FUNCTION MENU”.

(2) “Tools (Command 5)” -> “View Events (Command 0)” (3) Then, you will see the following message from LED

screen:

A 01/16 15:45:25 FRI 00001 001

Work Status :

A: Duty On

B: Duty Off

C: Overtime on

D: Overtime off

E: Break out

F: Break RTN

G: Go

H: Return

Date Time

Serial Number

Week User Address

Page 13: Soyal Ar727h Mu En

12

Error (Red)

Input Indicator Arming (Green)

Alarm (Red)

Transmission:Receive (Green)

OK (Green)

Reading (Green)

Send (Red)

4. Front Panel & Functions Keypad

Attendance Press 1 time Press 2 times

F1 Up Duty on Break out F2 Down Duty off Break RTN F3 Correct Overtime on Go F4 Overtime off Return * Esc # Enter

Other: ◎ Press * + Master Code (default : 123456, changeable) + #,

to enter “Function Menu” ◎ Before card editing finished, the master could enter “Function Menu”

and press 0 + F4 for all cards entrance allowance. ◎ Press * + # to lock / unlock keypad immd.

Page 14: Soyal Ar727h Mu En

13

Functions:

1. System will automatically exit from FUNCTION MENU, if no key or card entry is made within 30 seconds.

2. In FUNCTION MENU, LED [OK] will flash continuously and quickly.

3. In card access mode, flashing qualified card on the unit LED [OK] and LED [Reading] will light up, a beep sound and LCD panel message shown [OK],

4. Flashing unqualified card on the unit LED [ERROR] and LED [Reading] light up, two beeps sound and LCD panel message shown [Invalid Card!].

5. Green LED [ARMING] light up in “Arming On”.

6. Red LED [ALARM] lights up if any abnormal condition arisen.

7. Continuous wrong “PIN Code” or “Master Code” will make keypad locked for 30 seconds, LED [Error] light up and LCD panel shown [keypad Locked].

8. Once Alarm arisen, user must push exit button or flashing qualified card to release and return to standby state.

9. Transmission: Receive [Green] lights up when it receives message from PC or its external reader. Send [Red] lights up when AR-727H sends data to PC

Page 15: Soyal Ar727h Mu En

14

5. Mode 4 / 8 / 9 Pre-explanation Arming PWD (4 digits)

Default value:1234 Could be setup via Function Menu (Function no. 38)

PIN Code (4 digits) Could be setup via Function Menu (Function no. 21) Or, via 701 Client \ Setting \ User card

Duress Code (4 sets, 4 digits) Networking System:

Default value:1111 ; 2222 ; 3333 ; 4444 Changeable via 701 Server\ Setting \ 701 Configuration \

Duress Code Stand-alone System:

Default value:4321 Changeable via Function Menu (Function no. 48)

Force on/off Code (4 sets, 4 digits) Networking System:

Default value:1111 ; 1111 ; 1111 ; 1111 Changeable via 701 Server\ Setting \ 701 Configuration \

Duress Code

5.1 Card Editing After entering Function Mode, user uses following order to edit cards.

Function Nbr. Add→Card ID 11 Add→RF learn 12 Delete→Addr 15 Delete→ID# 16 Recover→Addr 17 Recover→ID# 18

Page 16: Soyal Ar727h Mu En

15

How to edit ten pcs sequential cards? ( Default access mode is Card only)

Step1: * + 1 2 3 4 5 6 + #

enter the “FUNCTION MENU”

Step2: Add/Delete (command 1)

Step3: Add→RF learn (command 2)

Step4: Then, LCD display will show as follow:

Please follow LCD display indicator to edit card

Step5: InputStartAddr (0-00999)

Enter 1, start from user no. 1

Step6: Tag Uints (pcs) Must be Sequence (1-00999)

Enter 10

Step7: Close Tag Into RF Area

Present the lowest card code of card to the unit.

5.2 Access Mode Users can select one of the following access modes 5.2.1 Card Only

Access the door by flashing card

Open door & turn Arming on / off: Flash card, then press Arming PWD + F1

Not open door & turn arming on / off: Press * + Arming PWD, then flash card

5.2.2 Card and PIN

Flash card, then press PIN Code + #

Open door & turn Arming on / off: Flash card, press PIN code & #, then Arming PWD + F1

Not open door & turn arming on / off: Not available

Page 17: Soyal Ar727h Mu En

16

How to set access mode of user is card and PIN?

Step1: * + 1 2 3 4 5 6 + #

enter the “FUNCTION MENU”

Step2: User Setting (command 2)

Step3: Access Mode (command 2)

Step4: Enter user number, Then, LCD display will show as follow:

1:Card 2:or PIN 3:& PIN 4:Pause Data: 1

Please select number 3: & PIN

Step5: Return to main menu to set the password of user

Step6: User Setting (command 2)

Step7: Password (command 1)

Step8: Enter user number

Then, LCD display will show as follow:

Input 4 Digit No. Range:0001~9999 Data:

5.2.3 User address and PIN (Mode 4)

Press keypad: User address (5 digit), then PIN code & #

Open door & turn Arming on / off: User address, press PIN code & #, then Arming PWD + F1

Not open door & turn arming on / off: Not available

How to set access mode of user is card or PIN? Step1: * + 1 2 3 4 5 6 + #

enter the “FUNCTION MENU”

Step2: User Setting (command 2)

Step3: Access Mode (command 2)

Step4: Enter user number, Then, LCD display will show as follow:

1:Card 2:or PIN 3:& PIN 4:Pause Data: 1

Page 18: Soyal Ar727h Mu En

17

Please select number 2:or PIN

Step5: Return to main menu to set the password of user

Step6: User Setting (command 2)

Step7: Password (command 1)

Step8: Enter user number

Then, LCD display will show as follow:

Input 4 Digit No. Range:0001~9999 Data:

5.2.4 PIN only (Mode 8)

Same as Card Only

Or, press keypad

◎ Door access: PIN code (4 digit)

◎ Open door & turn Arming on / off:

PIN code & #, then Arming PWD + F1

◎ Not open door & turn arming on / off: Not available

How to set access mode of user is PIN only? Step1: * + 1 2 3 4 5 6 + #

enter the “FUNCTION MENU”

Step2: User Setting (command 2)

Step3: Access Mode (command 2)

Step4: Enter user number, Then, LCD display will show as follow:

1:Card 2:or PIN 3:& PIN 4:Pause Data: 1

Please select number 2:or PIN

Step5: Return to main menu to set the password of user

Step6: User Setting (command 2)

Step7: Password (command 1)

Step8: Enter user number, Then, LCD display will show as follow:

Input 4 Digit No. Range:0001~9999 Data:

Page 19: Soyal Ar727h Mu En

18

5.2.5 Change PIN code

AR-727H connects with PC, running 701 client and set PIN code variable. By user: Flash card, then press PIN code (4 digit) twice + #)

By 701 client \ setting \ user card

Not connecting with PC Entering Function menu \ User setting \ Password

5.3 Duress function

This function could help users to send a message to the computer

asking for help.

Only available in networking state, running 701 Server and setting

4 sets of Duress code on PC. (Anyone of these 4 sets is workable.)

This function is not available for CARD ONLY access mode and mode

8 directly 4-digit PIN.

Access Mode Command Format

Card Only Not available

Card and PIN Flash card, then press Duress code & #

Users addr. and PIN

(Mode 4)

Press user address,

then Duress code & #

PIN Only (Mode 8) Duress code

Page 20: Soyal Ar727h Mu En

19

5.4 Force on/off Code (4 sets, 4 digits)

Only workable in networking system, running 701 Server and setting 4 sets of Force code on PC. (Anyone of these 4 sets is workable.) User could press related code to turn on / off its connected

equipment, diagram as below.

After access OK, press following order to turn on / off its

connected equipment.

Access mode ON/Off Order

ON Flashing card+Force code+Code+0+# Card only

Off Flashing card+Force code+Code+1+#

ON Flashing card+User code +Force code+Code+ 0+# Card + user

code Off Flashing card+User code +Force code+Code+1+#

ON User no. +User code +Force code+Code+ 0+# User no. + user

code (Mode 4) Off User no. +User code +Force code+Code+ 1+#

ON User code +Force code+Code+0+# User code only

(Mode 8) Off User code +Force code+Code+1+#

PC board of Controller AR-716EV2 / AR-727E

COM

JP4

V12CN5

DI.4

DI.2DI.1

DI.3

COM

D10D9

D11

K4RELAY

K3

D12

RELAY

JP3

K1

K3K4

K2K2

RELAYRELAYK1

Relay Code K1 16 K2 17 K3 18 K4 19

Page 21: Soyal Ar727h Mu En

20

This function is good for force control television, air conditioning, audio, etc. by Relay-1, 2, 3, 4 on the multi-door networking controller. To avoid the conflict of the use of each controller relay, it is

user responsibility to define each controller relay for one purpose use only.

Page 22: Soyal Ar727h Mu En

21

6. Mode 6 6.1 Card Editing

Under Mode 6, the system built in card code from 00001 to 63200 itself, so user can only suspend or recover cards, not allowed to add or delete.

The card which its card code is over than 63200 can’t be used under Mode 6.

After entering Function Mode, user uses following order to edit cards.

Function Nbr. Suspend→Addr 13 Delete→Addr 15 Recover→Addr 17

How to start / stop using cards? Example: Start using cards, which card ID from 12345: 00001 to

12345: 00100, totally 100 cards in sequence. Step1: Entering Function Mode Step2: Recover -> Addr. (Order no. 17) Step3: Input Start Addr. -> 00001 Step4: Input End Addr.-> 00100 Succeed!

6.2 Access Mode Under Mode 6, with different Arming PWD and Duress Code, users

have different access mode as below.

Arming PWD

= 0

Arming PWD

≠0

Duress Code

=0

Duress Code

≠0 Mode 6

Access Mode Card only Card and

Arming PWD

Duress Code

not workable

Duress Code

only

Page 23: Soyal Ar727h Mu En

22

7. Quick Guide (Function Menu) Under Function Menu, you could just press the indicative nbr. to get into concerning set-up screen directly.

Function Nbr. Function Nbr.

Add→Card ID 11 Alarm Relay Tm 36 Add→RF – learn 12 Arming Delay Tm 37 Suspend→Addr 13 Arming PWD 38 Suspend→ID # 14 Arming Pulse 39 Delete→Addr 15 Delete→ID # 16 Auto Relock 41 Recover→Addr 17 Egress (R.T.E.) 42 Recover→ID # 18 Attendance 43 Antipass Group 19 Master Node 44 Force Open.. 45 Password 21 Close & Stop 46 Access Mode 22 Anti-pass back 47 Extend Options 23 Duress Code 48 Single Floor 24

Multi Floors 25 Language (English) 511 Master Code 52 Master Range 53 Terminal Port 54 AR721R32 Node 55 Node ID 31 Open Time Zone 56 Auto Open Zone 32 Information 57 Door Relay Tm 33 Clock Setting 58 Door Close Tm 34 Control Mode 59 Alarm Relay Tm 35 View Events 50

Page 24: Soyal Ar727h Mu En

23

8. Function description 24 Single Floor To setup user for single floor access

(This function is only workable under the situation that AR-727H combined with AR-401RO16 and Control Mode is not Mode 6.)

25 Multi Floors To setup user for multi floors access (This function is only workable under the

situation that AR-727H combined with AR-401RO16 and Control Mode is not Mode 6.)

For example: User 0001 access to floor 17,

22, 31, 32 (Supposed no basement)

1. Entering “Function Menu”

2. Press 25

3. Enter user address: 00001

4. Select range: 2 (for 17 – 32)

1: 01 –16 2: 17 – 32

5. 0 -> stop 1 -> Yes

1000010000000011

31 Node ID To setup Node ID (default: 001), range from 001 to 254

33 Door Relay Tm To setup how long the time will be that door close after a card flashing. Range: 0 ~ 600 (sec.) To set value “0” will make door keep opening, after 2nd card flashing, then door close. (Default value: 7 sec.)

Page 25: Soyal Ar727h Mu En

24

34 Door Close Tm Extended time for door opening time.

(Default value: 15 sec.)

35 Alarm Relay Tm When abnormal condition arisen, how long the alarm will take place. Range: 0 ~ 600 (sec.) To set value “0” will make alarm relay keep on until disarming, then alarm relay off. (Default value: 7 sec.)

36 Alarm Delay Tm The time between setting Alarm on and its real starting working time. (Default value: 1 sec.)

37 Arming Delay Tm The time between setting Arming on and its real starting working time. Range: 0 ~ 600 (sec.) (Default value: 1 sec.)

39 Arming Pulse Range: 0 ~ 2500 (sec.)

TTT = 000: Latch (Toggle) (Default value: 1 sec.)

56 Open Time Zone Set door open / close automatically. Details:

1. Enter “Function Menu”

2. Setup opening time first, Function no. 56

3. Auto Open Zone, Function no. 32

1: Yes 2: No

Page 26: Soyal Ar727h Mu En

25

9. Special Design 9.1 AR-727H connected with 2 pcs of AR-661U long-range

reader (Set one AR-661U being Exit reader and the other one being Entry reader) to apply to Anti-pass back. CPU version must be at least 3.2 or up. In stand-alone system, without connecting to any

controller, AR-727H could integrate with 2 pcs of AR-661U to apply to anti-pass back. ◎ No special setting up necessary for AR-727H. ◎ Set one AR-661U with wiegand 34 bit format output

and the other one with 38 bit. (Please refer to manual of AR-661U to have details.)

◎ Set card to have anti-pass back checking. (Order no. 19)

This special design is especially suitable for car parking control.

The special design is only workable with AR-661U, not available with AR-721U, AR-721K. (wiegand reader)

Soyal Product AR-829E (CPU version at least 5.6) 、AR-721H4 (CPU version at least 3.1V) also have this special design.

The original function that AR-727H connecting with one wiegand reader (AR-661U, AR-721U, AR-721K) to apply to Anti-pass back is still available.

Page 27: Soyal Ar727h Mu En

26

9.2 How AR-727 connects with a weigand reader (AR-721K, AR-721U, AR-661U) and to apply to anti-pass back?

(1) Main manu (2) Input command:47,

enable antipass—1:YES 2:NO,input1; in or out –1:in 2: out,input default value(1 or 2 ).

attention:if AR-727H would be in door and then the weigan reader would be out door.

9.3 How to set multi AR-727H connects with a net controller

and to apply to anti-pass back? Both card and reader have to apply to anti-pass back.

1.card setting: step1:701 Client step2:user card edit step3:mark anti-pass back.

. 2. reader setting (AR-727H): step1:main manu step2:command 47 step3: enable antipass—1:YES 2:NO,input1;

in or out –1:in 2: out,input default value(1 or 2 ). 9.4 How to setting the weigand reader (AR-721U, AR-721K,

AR-661U) and AR-727H at the same net controller to apply to the anti-pass back? Both card and reader have to apply to anti-pass back

Card setting: step1:701 Client step2:user card edit step3:mark anti-pass back.

Page 28: Soyal Ar727h Mu En

27

Hardware setting: weigand reader (AR-721U, AR-721K): Set controller WG port as in or out if WG port is port 1 then would be in door and port 2 would be out door. Software setting: 701 Server.

Step1: 701E Parameter Step2: door number Step3:mark [Door Number 17]or [Door Number 18] AR-727H setting: (1) main manu (2) command 47

enable anti-pass back 1:YES 2:NO,input1; in or out –1:in 2: out,input default value(1 or 2)

Attention: if weigand reader would be in door then AR-727H would be our door.

AR-716Ei PCB

Port 1 (Channel 17) Port 2 (Channel 18)

Page 29: Soyal Ar727h Mu En

28

9.5 How to set that user arrive single floor or multi-floor? Either way to set user arrive single floor or multi-floor function. 1. Set by keypad for standalone installation (AR-727H+AR-829L485+AR-401RO16) Set user arrive single floor

Step1: * + 1 2 3 4 5 6 + # enter the “FUNCTION MENU”

Step2: User Setting (command 2) Step3: Single Floor (command 4) Step4: Enter user address and set to access which one floor. Set user arrive multi-floor

Step1: * + 1 2 3 4 5 6 + # enter the “FUNCTION MENU”

Step2: User Setting (command 2) Step3: Single Floor (command 5) Step4: Please refer to “function description” to get detailed

explanation. 2. Set by software for networking installation

(PC+AR-801CM+AR-716EV2+AR-727H+AR-829L485+ AR-401RO16)

Page 30: Soyal Ar727h Mu En

29

Go to 701 Client \ User card edit \ User Access Floor Edit

Select User. Select controller and reader node that manages that elevator. Select the card user can access which floor. Click “Write to Controller”.

9.6 How to set AR-401RO16 parameter?

(ex. Card Release Tm) Step1: * + 1 2 3 4 5 6 + # enter the “FUNCTION MENU” Step2: Tools (command 5) Step3: AR-721R32 Node (command 5) Step4: Input NodeID, Card Release Tm and P.B Release

Tm (Default value: 7 sec.) Note: 1. AR-401RO16 has no push button input function, but you still enter push button input second in order to complete this

Page 31: Soyal Ar727h Mu En

30

command. Otherwise, this command will be failed. 2. They are one-way transmission is between AR-727H and AR-401RO16, so you will find that you change Card Release Tm from 7 sec. to 10 sec. But the parameter will be stay default value 7 sec. Don’t worry about this matter. Actually, it is already changeable.

Page 32: Soyal Ar727h Mu En

31

10. Installation 10.1 Steps:

1. Use the screwdriver to screw the mounting plate on the wall.

2. Pull cable ends through the access hole in the mounting plate. Connect plug 7 pins to socket CN1 Connect plug 4 pins to socket CN2 Connect plug 8 pins to socket CN3 Connect plug 3 pins to socket CN5

3. Attach AR-727H to the mounting plate and install screw (supplied) into the hole at the bottom with the Allen wrench (supplied).

4. Apply power. Green LED [POWER] will light up, a beep sound and LCD panel message will show up.

Page 33: Soyal Ar727h Mu En

32

10.2 Installation Notice:

1. The distance between AR-727H and its auxiliary reader should be more than 50 cm and less than 12 meter. (Suggested value) AR-727H could be fixed inside the secure area as an exit and its auxiliary reader outside as an entrance reader, but not directly behind AR-727H.

2. The reading range of AR-727H will be up to15 cm. However, when AR-727H or its auxiliary reader is mounted directly on a metal surface, the reading distance decreases slightly. To reduce this effect, we suggest inserting a wood or plastic between the mounting surface and the unit.

3. Exit Switch input must be a dry contact, without voltage present.

4. AR-727H does not supply power to operate electric strike or magnetic locks, a separated power supply are required. Refer to strike or magnetic lock manufactures instructions, if common power supply is used for both AR-727H and electronic door lock; make sure to install the diode, which is provided with AR-727H.

5. Power supply should be at least 9 VDC to max. 24 VDC and at least 3W. DC power should be clean and filtered with no more than 0.3 VAC ripple (Peak to Peak). Do not run AC power in the same cable with DC power to AR-727H. While it is always preferable to use a separate power supply for AR-727H and strike.

Page 34: Soyal Ar727h Mu En

33

6. Run the following cables to the AR-727H location. Conduit is recommended to reduce the effects of EMI/RFI and for physical protection of the wires.

Cable Types and Distances

Wire Application Cable Type Description

From Power Supply 2-cond, 18-22 AWG n/a

From Locking Device and

power supply or gate

operator

2-cond. See Mfr’s

Specifications

n/a

From external alarm

system’s Door Monitor

Switch (for shunting)

2-cond, 18-22 AWG 100 m

From Exit Button 2-cond, 18-22 AWG 100 m

From Optional Auxiliary

Reader

2-cond unshielded 22

AWG, plus a separate

4-cond, shielded 22-24

AWG cable

50 cm - 12 m

Page 35: Soyal Ar727h Mu En

34

11. Wiring Table 1 - Connector CN3 Color Coding

Wire Application Wire Color Description

1 Blue White (N.O.)DC24V1Amp Door Relay

2 Purple White (N.C.)DC24V1Amp

Door/Alarm Relay 3 White (COM)DC24V1Amp

Door Sensor 4 Orange Negative Trigger Input

Exit Switch 5 Purple Negative Trigger Input

Alarm Relay 6 Gray N.O. / N.C. Optional

7 Thick Red DC Power 12V Power

8 Thick Black DC Power 0V

Table 2 - Connector CN1 Color Coding

Wire Application Wire Color Description

1 Thick Green RS-485(B-) Networking

2 Thick Blue RS-485(A+)

3 Thin Blue Wiegand DAT:1 Input

ABA Clock Input Wiegand

4 Thin Green Wiegand DAT:0 Input

ABA Data Input

Buzzer 5 Pink Buzzer Output 5V/100mA,

Low

6 Brown LED Green Output

5V/20mA, Max LED

7 Yellow LED Red Output

5V/20mA, Max

Page 36: Soyal Ar727h Mu En

35

ON

Table 3 - Connector CN5 Color Coding

Wire Application Wire Color Description

1 Red N.C.

2 Orange COM Tamper Switch

3 Yellow N.O.

Serial Port 2 Yellow

White

Serial output (Transistor open collector)

(4800,N,8,1)

Arming LED 3 Red White Arming output (Active low)

Table 4 - Connector CN2 Color Coding

Function Wire Color Description

Card Present 1 Brown Latch type

Arming Setting Switch 4

Orange

White

Card present output active low

(Transit output)

Purple White

Blue White

COM

Gray

White

NO

NC

JP1 Alarm Relay

Door Relay K1

K2

OFF

Page 37: Soyal Ar727h Mu En

36

12. Installation diagram 12.1 Magnetic lock

NO.

COM.- G

ND

+12VDC

The installation of 727H and magnetic lock

Whi

te(

CO

M. )

Lock

( -G

ND

)P

urpl

e W

hite

( N

.C. )

-GN

D

Power Supply12VDC 2A

Pur

ple

Bla

ck(

- GN

D )

Red

( +

12V

DC

)

DOOR EXITPush Button

CN

3

Power Supply12VDC 2A

Lock(+12VDC )+12VDC

Magnetic Lock

CN3

AR-727H

CN5

CN1

CN

2

Page 38: Soyal Ar727h Mu En

37

12.2 Electric bolt lock

- GND

- GND

+12VDC

NO.

COM.

12VDC 2APower Supply

The installation of 727H and electric bolt lock

Push ButtonDOOR EXIT

Pur

ple

Bla

ck(

- GN

D )

Red

( +

12V

DC

)

CN

3

Blu

e W

hite

( N

O. )

Whi

te(

CO

M. )

Lock( -GND )

Lock(+12VDC )12VDC 2APower Supply Electric Bolt Lock

CN5

AR-727H

CN

2

CN3CN1

+12VDC

Page 39: Soyal Ar727h Mu En

38

12.3 Electric strike

+12VDC- GND

NO.

COM.

The installation of 727H and electric strike

Power Supply12VDC 2A

DOOR EXITPush Button P

urpl

e

Bla

ck(

- GN

D )

Red

( +

12V

DC

)

Blu

e W

hite

( N

O. )

Whi

te(

CO

M. ) C

N3

Lock(+12VDC )+12VDC12VDC 2APower Supply

Electric Strike

Lock

( -G

ND

)

-GN

D

AR-727H

CN5

CN3CN1

CN

2

Page 40: Soyal Ar727h Mu En

39

12.4 Magnetic door contacts and alarm system

- GN

D

+12

VD

C

ALM

.

N.C

.

CO

M.

N.O

.

+12

VD

C

- GND+12VDC

The installation of 727H, magnetic door contacts and alarm system

Alarm System

Power Supply12VDC 2A

Bla

ck(

- GN

D )

Red

( +

12V

DC

)

Gray( ALM. )

Red

( +

12V

DC

)

Bla

ck(

- GN

D )

Mag

netic

Doo

r C

onta

cts(

CO

M. )

CN

3

Ora

nge(

Doo

r S

enso

r )M

agne

tic D

oor

Con

tact

s ( NC

. )

12VDC 2APower Supply

Magnetic doorcontacts

CN1

CN5

AR-727H

CN

2

CN3

Page 41: Soyal Ar727h Mu En

40

12.5 Wiegand reader

Green

Blue

Yellow

PurpleBrown

The

inst

alla

tion

of 7

27H

and

aux

iliar

y re

ader

s

721U

12V

DC

2A

Pow

er S

uppl

y

Red

(+12

VD

C)

Bla

ck

Red

1

721K

Red

Black

CN

1

1~

Yel

low

Bro

wn

CN

2G

reen

Pin

k

Blu

e

661U

Bla

ck(-

GN

D)

Bro

wn

Yel

low

Gre

en

Pin

k Blu

e

727H

CN

3

CN

1

Page 42: Soyal Ar727h Mu En

41

AR

-737

U

Bla

ck

Pow

er S

uppl

y12

VD

C 2

A

The

inst

alla

tion

of 7

27H

and

aux

iliar

y re

ader

s 73

7U

Red

Purple

Blue

Green

BrownYellow

AR-727H

Yello

wB

lack

(-G

ND

)

Red

(+12

VD

C)

1

CN

3

Gre

en

Bro

wn

Pin

k

Blu

eC

N1

Page 43: Soyal Ar727h Mu En

42

12.6 Networking installation 12.6.1 two set of AR-716EV2 parallel installation

ToN

ode:

009

Nod

e: 0

16

ToN

ode:

008

Nod

e: 0

01

Not

e:1.

The

conn

ectin

g d

isan

ce b

etw

een

the

801c

m a

nd y

our

pc

can

not b

e m

ore

than

2m

.

AR

-727

H

AR

-727

HA

R-7

27H

Green

Blue

Blue

Green

Green

Blue

Green

Blue

CN

1

CN

1C

N1

conn

ect t

o P

C

15V

DC

2A

Pow

er S

uppl

y

Con

trol

ler

Nex

t

Red

Bla

ck

Blue

BlackGreen

Red

AR

-727

H a

nd A

R-7

16E

/727

E n

ewor

king

inst

alla

tion

AR

-716

E

or

AR

-727

E

CN

1C

N3

CN

3C

N1

CN

5

CN2

~~

CN

1

~~

CN

1C

N3

CN

5

CN2

CH

1

JP2

JP1

HO

ST

CN

3C

H2

CN

2

BV+

Vin Vin

GN

DBV

-

727i

CN2

AR

-727

H

CN

5

CN

3C

N1

CN2

CN

5

~~~~

JP1

JP2

Vin Vin

BV+ BV

-

CN

2

CN

1 CN

3

CH

1

HO

ST

CH

2

727i

AR

-716

E

or

AR

-727

E

GN

D

CN

1

Page 44: Soyal Ar727h Mu En

43

12.6.2 AR-716EV2, AR-829E and AR-727H parallel installation

727i

CN

3 Red

JP1

JP2

Bla

ck

CH

2

HO

ST

CN

2C

N1

CN

2

AR

-727

H, A

R-8

29E

and

716

EV

2 ne

twor

king

inst

alla

tion

CN

2

Green

Blue

AR

-829

EA

R-7

27H

線紅

線黑

GN

D

VinC

N1

Vin

BV-

BV+

綠 線線藍

~~C

H1

Pow

er s

uppl

y15

VD

C 2

A

CN2

CN

1

CN

5

CN

3

AR

-727

H

Blue

Green

Nod

e: 0

09

Nod

e: 0

16

CN

1

CN

3C

N1

CN

5

CN

1

Green

Blue

CN

3

CN

5

CN

1

CN

1

Green

Blue

CN2

AR

-727

H

CN2

Nex

t Con

trolle

r

~~

AR-7

16E

V2 o

r

AR-7

27E

i

Min

imum

2 m

eter

conn

ect t

o PC

Page 45: Soyal Ar727h Mu En

44

12.7 Lift controller AR-401RO16 installation

Pow

er S

uppl

y12

VD

C 2

.4A

Dia

gram

of A

R-7

27H

and

AR

-401

RO

16

Bla

ck

Yel

low

-+

CN

CN

1

CN

CN

3

Red

Red

+

- +

Bla

ck

DC 12V

Gre

en

Blu

e

--+

+-

+-

Page 46: Soyal Ar727h Mu En

45

12.8 AR-727H & AR-801CM & PC installation

The installation of 727H, 801CM and PC

12VDC 2APower Supply

Push ButtonDOOR EXIT

COM.

NO.

Red

( +1

2VD

C )

Bla

ck (

- GN

D )

Pur

ple

Whi

te (

CO

M. )

Blu

e W

hite

( N

O. )

12VDC 2APower SupplyElectric Bolt Lock

Lock ( -GND )

Lock (+12VDC ) +12VDC

- GND

CN3

AR-801CM

CN

2CN1

CN3CN1

CN5

Blue

Green

Power Supply15VDC 2A

AR-727H

Gre

en

Minimum 2 meterconnect to PC

To PC

Blue

Black

Red

Page 47: Soyal Ar727h Mu En

46

13. Troubleshooting

Questions Answer No appearance 1. Check power, if it is 9 – 24 VDC adaptor?

2. Check if the polarity is correct? Can not connect to PC

1. Check if Transmission LED light up? (Green / Red)

2. Check 701 Server, if set-up is correct? Please refer to 701 Server manual for details.

3. If connecting to PC via AR-801CM converter, check if the power (Green) light up?

How to find out Card ID with a user address?

1. Entering “Function Menu” 2. Press 11 3. Entering “user address”

How many Cards exist in system?

1. Entering “Function Menu” 2. Press 57

Page 48: Soyal Ar727h Mu En

47

14. Return of Products Please contact the distributor who sold the unit. All service and repairs must be done through an authorized distributor. 15. Warranty SOYAL warrants that the product(s) shall be free from manufacturing defects in materials and workmanship for a period of twelve (12) months from the date of delivery provided that the product was properly installed and used. The foregoing warranty shall not apply to defects resulting from abuse, misuse, accident, unauthorized alteration or repair, neglect, acts of God (such as floods, fire, etc.). SOYAL shall, at its option, either repair or replace product(s) which prove to be defective within the warranty period. SOYAL will replace any product found to be defective within the first three months of purchase provided said product was properly installed and used. Distributor agrees to insure the product or assume the risk of loss or damage in transit to prepay shipping charges and to use the original shipping container or equivalent. Customers shall seek assistance from the distributor who sold you product(s). Repaired or replaced product(s) are warranted for ninety (90) days from the date of repair or replacement, or for the remainder of the original product’s warranty period, whichever is longer.

Note: Don’t tear a paster such as S/N: 727H Warranty B-0307-000107 on the PCB board, it is SOYAL warranty.

Page 49: Soyal Ar727h Mu En

48

16. Transponder Record Table Be sure to record the user number, the user name, the card ID number (site code: card code), and the user code and keep this information in a secure place. A black user log form has been included for purpose. Do not write on this form; use it as a photocopy master.

User Add. User Name Site code: Card code PIN code Programmed by: Date: Company Name: Company Address: City: Other Information:

Page 50: Soyal Ar727h Mu En

49

17. Specification

Voltage 10 – 24 VDC

Current <3W (250 mA @ 12VDC)

RF Frequency 125 KHz

Reading range 10 – 18 cm

User Interface 16 metallic texture keypads、beep、128*64 dot LCD panel and 8 LED indicator.

Networking RS – 485, 9600,N,8,1

External reader port

Suitable for all WG、ABA reader; 125K、13.56M (Mifare) or 2.4G reader

Door Relay 2A / 12V N.O. / N.C. / COM 0.1 ~ 600 sec. / Latch type

Alarm Relay 2A / 12V N.O. / N.C. / Jumper selectable 0 ~ 600 sec.

DI input Egress button /Door sensor/Arming switch

Transistor output Arming /Duress /Card sensor

Tamper switch Limit Switch(N.O. N.C. COM.)

Serial Port Supported for AR-721R32、LED display、 Relay board、Printer etc.(4800,N,8,1)

Material ABS

Dimensions(mm) 127 (L) * 91 (W) * 46 (H)