sphenix time projection chamber · overview checking compatibility between fee v1.2 (io-1709-1b)...

10
sPHENIX Time Projection Chamber 1 16-APR-2020 R3 Padplane Design Review J. Kuczewski 16 April 2020

Upload: others

Post on 15-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: sPHENIX Time Projection Chamber · Overview Checking compatibility between FEE v1.2 (IO-1709-1B) and SUNYSB’s R3 Readout Plane. – Are the ground pins correct? – Is the one-wire

sPHENIX Time Projection Chamber

116-APR-2020

R3 Padplane Design Review

J. Kuczewski

16 April 2020

Page 2: sPHENIX Time Projection Chamber · Overview Checking compatibility between FEE v1.2 (IO-1709-1B) and SUNYSB’s R3 Readout Plane. – Are the ground pins correct? – Is the one-wire

Overview

● Checking compatibility between FEE v1.2 (IO-1709-1B) and SUNYSB’s R3 Readout Plane.– Are the ground pins correct?

– Is the one-wire ID/EEPROM pin correct?

– Is the connector spacing correct?

– Is the footprint correct?

Zig-Zag Pads 4 GEMs installed on Pad Plane Readout Side of Pad Plane Readout Electronics (FEE)

Page 3: sPHENIX Time Projection Chamber · Overview Checking compatibility between FEE v1.2 (IO-1709-1B) and SUNYSB’s R3 Readout Plane. – Are the ground pins correct? – Is the one-wire

The Connectors

FEE v.1.1 (Rev A)R2 Readout Plane Connectors

FEE Input ConnectorSAMTEC Part:

SEAF-30-01-L-06-1-RA-GP-TR

Pad Plane Output ConnectorSAMTEC Part:

SEAM-30-02.0-L-06-1-A-K-TR

Page 4: sPHENIX Time Projection Chamber · Overview Checking compatibility between FEE v1.2 (IO-1709-1B) and SUNYSB’s R3 Readout Plane. – Are the ground pins correct? – Is the one-wire

Pad Plane & FEE Layout

Page 5: sPHENIX Time Projection Chamber · Overview Checking compatibility between FEE v1.2 (IO-1709-1B) and SUNYSB’s R3 Readout Plane. – Are the ground pins correct? – Is the one-wire

Pad Plane & FEE Spacing

Page 6: sPHENIX Time Projection Chamber · Overview Checking compatibility between FEE v1.2 (IO-1709-1B) and SUNYSB’s R3 Readout Plane. – Are the ground pins correct? – Is the one-wire

Connector A: Top

Page 7: sPHENIX Time Projection Chamber · Overview Checking compatibility between FEE v1.2 (IO-1709-1B) and SUNYSB’s R3 Readout Plane. – Are the ground pins correct? – Is the one-wire

Connector A: Middle

Page 8: sPHENIX Time Projection Chamber · Overview Checking compatibility between FEE v1.2 (IO-1709-1B) and SUNYSB’s R3 Readout Plane. – Are the ground pins correct? – Is the one-wire

Connector A: Bottom

Page 9: sPHENIX Time Projection Chamber · Overview Checking compatibility between FEE v1.2 (IO-1709-1B) and SUNYSB’s R3 Readout Plane. – Are the ground pins correct? – Is the one-wire

1-Wire ID/EEPROM

Pulled up 2.7VOn 2.5V bank

Page 10: sPHENIX Time Projection Chamber · Overview Checking compatibility between FEE v1.2 (IO-1709-1B) and SUNYSB’s R3 Readout Plane. – Are the ground pins correct? – Is the one-wire

Summary

– Are the ground pins correct?● Yes

– Is the one-wire ID/EEPROM pin correct?● Yes

– Is the connector spacing correct?● Yes (Dan, can you double check?)

– Is the footprint correct?● Yes