SQXF Coil 2 Status 9/9/2014 2
SQXF Coil 2 Status Outline
• Splice block removal, bolts seized– Next coil use boron nitride
• Power lead splice complete– SnPb solder & activated flux used– Very difficult using silver solder and low chloride flux (Nokorode)
• Heater/VT trace hi-pot test passed, 1kV• Straight section (poles) preparation complete• 2 voltage taps out of place requiring jumpers, DR written.
(photos)• Quench heater over saddle/splice blocks procedure. (photos)• Applied mold release to impregnation tooling• Plan
Fred Nobrega
SQXF Coil 2 Status 9/9/2014 3
SQXF Coil 2
• Seized bolts – At coil winding use boron nitride
Fred Nobrega
SQXF Coil 2 Status 9/9/2014 4
SQXF Coil 2
• Power lead splice complete– SnPb solder & activated flux used– Very difficult using silver solder and low chloride flux
(Nokorode)
Pre-tinning of reacted cable
Fred Nobrega
SQXF Coil 2 Status 9/9/2014 6
SQXF Coil 2
• Straight section (poles) preparation complete
Fred Nobrega
SQXF Coil 2 Status 9/9/2014 7
SQXF Coil 2
• 2 voltage taps out of place requiring jumpers, DR written
Fred Nobrega
SQXF Coil 2 Status 9/9/2014 8
SQXF Coil 2
• 2 voltage taps out of place requiring jumpers, DR written.
Fred Nobrega
SQXF Coil 2 Status 9/9/2014 9
SQXF Coil 2
• Heater/VT trace over saddle/splice blocks procedure?
Fred Nobrega