ssd/flash for modern databases - percona · pdf filein this presentation flash technology...
TRANSCRIPT
![Page 1: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/1.jpg)
Peter Zaitsev, CEO, Percona
November 1, 2014 Highload++ 2014
Moscow,Russia
SSD/Flash for Modern Databases
![Page 2: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/2.jpg)
www.percona.com 2
Percona
• Percona Server
• Percona Xtrabackup
• Percona XtraDB Cluster
• Percona Toolkit
We love Open Source
Software
• Consulting
• Support
• Managed Services
We want to help you to
succeed with MySQL and
Beyond
![Page 3: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/3.jpg)
www.percona.com 3
In this Presentation
Flash technology overview
Review some of the available technology
What does this mean for databases ?
Specific opportunities for MySQL
![Page 4: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/4.jpg)
www.percona.com 4
Before SSDs
![Page 5: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/5.jpg)
www.percona.com 5
There were HDDs
Good at Sequential Read/Writes
RT=Seek Time + Rotation Latency
Reads/Write – Similar Latency
No Specific Write Limits
Retain data for a long time
One IO Request in Parallel
Low cost per GB
![Page 6: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/6.jpg)
www.percona.com 6
RAID and SAN
![Page 7: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/7.jpg)
www.percona.com 7
Using Many HDDs together
Caching Reads
Buffering Writes (Writeback Cache)
Better Sequential Read/Write speed
Better throughput at high concurrency
Higher IO latencies for uncached IO
![Page 8: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/8.jpg)
www.percona.com 8
Flash Revolution
Use Flash chips instead
of platters
No moving parts
No seeks
![Page 9: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/9.jpg)
www.percona.com 9
NAND Flash
Cell
Page/Read Block
Erase Block
Write but no overwrite
Wears with writes (erases)
![Page 10: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/10.jpg)
www.percona.com 10
Writing to the Flash
• Set all bits to “1111111…”
Erase
• Set some of the bits to 0: “0100111..”
Write
• Impossible. Do Erase, when Write
Change Zero to one
![Page 11: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/11.jpg)
www.percona.com 11
Types of NAND Flash
From AnandTech:
![Page 12: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/12.jpg)
www.percona.com 12
Flash Storage Design
Cache
Battery/Super Capacitor
Controller + Complex Firmware
Built-in Parallelism
![Page 13: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/13.jpg)
www.percona.com 13
Flash Controller Tasks
Write wear leveling
Garbage collection
Error correction
Bad block mapping
Read scrubbing
Read disturb management
Encryption
![Page 14: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/14.jpg)
www.percona.com 14
Flash Properties
Lots of IOs per device! (100K+)
Less random IO penalty
Writes more expensive than reads (but can be faster)
Limited by amount of writes
Limited retention
Concurrent execution on single device
Fast write acknowledgement (safe or not)
Can burst writes
![Page 15: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/15.jpg)
www.percona.com 15
Flash Interface Designs
DIMM
PCI-E
SFF-8639
SATA/SAS
FC and Network
![Page 16: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/16.jpg)
www.percona.com 16
Transitioning
AHCI NVMe
![Page 17: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/17.jpg)
www.percona.com 17
AHCI vs NVMe
• Source: AnandTech.com
![Page 18: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/18.jpg)
www.percona.com 18
Sandisk ULLtraDIMM
![Page 19: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/19.jpg)
www.percona.com 19
HGST Virident
![Page 20: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/20.jpg)
www.percona.com 20
Sandisk FusionIO
![Page 21: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/21.jpg)
www.percona.com 21
Intel P3700
![Page 22: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/22.jpg)
www.percona.com 22
Intel 730 (SATA)
![Page 23: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/23.jpg)
www.percona.com 23
mSATA
![Page 24: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/24.jpg)
www.percona.com 24
M.2 Interface
![Page 25: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/25.jpg)
www.percona.com 25
Violin Memory
![Page 26: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/26.jpg)
www.percona.com 26
“Consumer” vs “Enterprise”
Performance
Endurance
Durability
Retention
Encryption
![Page 27: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/27.jpg)
www.percona.com 27
Not your HDD
All HDDs are the same; All SSDs are
different
![Page 28: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/28.jpg)
www.percona.com 28
Evaluation
Performance changes over time
Empty Space Matters
Complex internals
Watch stability carefully
![Page 29: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/29.jpg)
www.percona.com 29
How Flash Fails
Clear write amount defined EOL
(but often can handle a lot more)
One day… it’s gone
“Power Loss Protection”
Internal ECC and redundancy
![Page 30: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/30.jpg)
www.percona.com 30
To RAID or not to RAID ?
More valuable for consumer grade
Watch for good Flash support
RAID controller logic may slow things down
Use a redundant array of inexpensive servers instead?
![Page 31: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/31.jpg)
www.percona.com 31
Redundancy
Device internal redundancy
Hardware RAID
Software RAID
Filesystem “RAID”
![Page 32: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/32.jpg)
www.percona.com 32
OS Support
Flash support is actively being improved
TRIM
Sparse Files
![Page 33: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/33.jpg)
www.percona.com 33 www.percona.com
Flash And Databases
![Page 34: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/34.jpg)
www.percona.com 34
Database History
Most have been designed in HDD time
Optimize for sequential IO
Count on cheap sequential writes
RAID, BBU to improve performance
![Page 35: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/35.jpg)
www.percona.com 35
It’s time for Flash
Your OLTP Database should
live on Flash
![Page 36: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/36.jpg)
www.percona.com 36
But What Flash ?
Pick a flash type that is right for your
application
![Page 37: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/37.jpg)
www.percona.com 37
IO vs Memory
![Page 38: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/38.jpg)
www.percona.com 38
Warmup
Much faster warmup times
Even if the database fits in memory, SSD might be justified
![Page 39: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/39.jpg)
www.percona.com 39
Tolerate more IO bound load
• 5ms
• Can do 20 IO/s for 100ms response time (non parallel)
HDD
• 0.1ms
• Can do 1000 IO/s for 100ms response time (non parallel)
Flash
![Page 40: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/40.jpg)
www.percona.com 40
Endurance
Might be a top consideration
![Page 41: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/41.jpg)
www.percona.com 41
Endurance Math
• 4400GB/day over 5 Years
• 1400MB/sec peak writes
• 66 days at peak write throughput
HGST FlashMax III 2200GB
• 72TB total life time writes
• 400MB/sec write
• 52 hours at peak write throughput
Crucial M500
960GB
![Page 42: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/42.jpg)
www.percona.com 42
Databases and Flash
How do we optimize databases to us
Flash best?
![Page 43: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/43.jpg)
www.percona.com 43
“Torn Page” problem
Flash can avoid this with little cost due to internal design
FusionIO NVMFS (Atomic Writes)
Copy-on-Write File Systems
• ZFS
• BTRFS
Filesystem level data journaling less preferred
• data=journal for EXT4
Skip-Innodb-double-write
![Page 44: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/44.jpg)
www.percona.com 44
Fast IO Path
Bypass Caching O_DIRECT
Native Asynchronous IO
Efficient Checksuming
Innodb_checksum_algorithm=crc32
Innodb_flush_method=O_DIRECT
![Page 45: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/45.jpg)
www.percona.com 45
IO Cost Accounting
Sequential vs Random IO balance
IO vs CPU Balance
Smaller page sizes might make sense
• innodb_page_size=4K
![Page 46: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/46.jpg)
www.percona.com 46
Less Pre-fetching
Most pre-fetched data must be used
Often best to try It out
![Page 47: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/47.jpg)
www.percona.com 47
Less merging on flushing
Do not assume flushing multiple sequential dirty pages has same cost
Innodb_flush_neighbors=0
![Page 48: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/48.jpg)
www.percona.com 48
Less Space on Disk
Innodb Compression (2x typical)
TokuDB Compression (5-10x typical)
Archiving data off OLTP System
![Page 49: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/49.jpg)
www.percona.com 49
Less Writes on Flash
Hybrid Flash/SSD System
Transactional Logs, Other logs on the HDD with RAID and BBU
Small Temporary objects on tmpfs
Innodb_log_file_size=<LARGE>
![Page 50: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/50.jpg)
www.percona.com 50
Logs on RAID can be fast
![Page 51: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/51.jpg)
www.percona.com 51
Single Intel 730 Sysbench
![Page 52: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/52.jpg)
www.percona.com 52
IOPS
![Page 54: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/54.jpg)
www.percona.com 54
Is Flash Too Fast ?
• Multiple instances might scale better
![Page 55: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/55.jpg)
www.percona.com 55
Other Thoughts
Host hardware and OS matter, especially with high end flash
Virtualization has higher relative overhead
Network higher relative overhead
![Page 56: SSD/Flash for Modern Databases - Percona · PDF fileIn this Presentation Flash technology overview ... SSD might be justified . 39 Tolerate more IO bound load • 5ms • Can do 20](https://reader031.vdocument.in/reader031/viewer/2022030407/5a8527dc7f8b9a882e8c0efe/html5/thumbnails/56.jpg)
www.percona.com 56 www.percona.com
Peter Zaitsev
@PeterZaitsev
https://www.linkedin.com/in/peterzaitsev
Thank You!