GENERAL NOTES
1. COMPLY WITH ALL CODES, ORDINANCES, AND GOVERNMENT AGENCIES.
2. ALL CONSTRUCTION IS TO COMPLY WITH THE 2014 OREGON RESIDENTIAL
SPECIALTY CODE, AS AMENDED BY THE STATE OF OREGON.
3. DIMENSIONS OF NEW CONSTRUCTION ARE TO FACE OF FRAMING, TO CENTER OF ROUGH OPENING OF DOORS, WINDOWS OR MULLED WINDOWS, & CONCRETE.
4. INSULATION VALUES (2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE)
UNDERFLOORS R-30 MIN.
WALLS R-21 MIN.
CEILINGS R-38 MIN.
5. VERIFY AND COORDINATE WITH CIVIL, LANDSCAPE, STRUCTURAL, PLUMBING, MECHANICAL, AND ELECTRICAL.
6. DO NOT SCALE DRAWINGS. CONTRACTOR SHALL RELY ON WRITTEN DIMENSIONS AS GIVEN. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT FOR
CLARIFICATIONS. ALL DIMENSIONS SHALL BE FIELD VERIFIED BY CONTRACTOR & COORDINATED W/ ALL OF THE WORK OR ALL TRADES. IF DISCREPANCIES
ARE FOUND, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT BEFORE THE COMMENCEMENT OR RESUMPTION OF WORK.
7. IF THE CONTRACTOR DISCOVERS AT ANY TIME THAT REQUIREMENTS OF THIS CONTRACT CONFLICT W/ OR ARE IN VIOLATION OF APPLICABLE LAWS, CODES,
REGULATIONS & ORDINANCES, HE SHALL NOT PROCEED W/ WORK IN QUESTION UNTIL ARCHITECT HAS BEEN NOTIFIED IN WRITING & WRITTEN DETERMINATION IS
MADE BY THE ARCHITECT. WHERE COMPLETED OR PARTIALLY COMPLETED WORK IS FOUND TO BE IN VIOLATION W/ APPLICABLE LAWS, CODES, REGULATIONS
OR ORDINANCES, CONTRACTOR SHALL BE REQUIRED TO REMOVE THAT WORK FROM THE PROJECT & REPLACE SUCH WORK W/ ALL NEW COMPLYING WORK
AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT.
8. CONTRACTOR SHALL PROVIDE & INSTALL STIFFENERS, BRACING, BACK-UP PLATES & SUPPORTING BRACKETS REQUIRED FOR THE INSTALLATION OF
CASEWORK, BATHROOM AND SHOWER ACCESSORIES & OF FLOOR-MOUNTED OR SUSPENDED MECHANICAL & ELECTRICAL EQUIPMENT.
9. CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES BELOW GRADE & RELATED SERVICE CONNECTIONS W/ THE RESPECTIVE UTILITY
COMPANIES.
10. CONTRACTOR SHALL PERFORM ALL WORK WITHIN PUBLIC RIGHTS-OF-WAY ACCORDING TO LANE COUNTY STANDARD PLANS & SPECIFICATIONS.
CONTRACTOR SHALL OBTAIN PERMITS FROM APPROPRIATE AGENCIES.
11. SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL EQUIPMENT & MATERIALS WHICH MUST INTERFACE & COORDINATE W/ OTHERS, WHETHER DETAILED OR NOT.
12. PATCH AND REPAIR ALL STRUCTURE, FRAMING, AND FINISHES AFFECTED BY CONSTRUCTION.
PROJECT DESIGN TEAM
CLIENT:
PEACEHEALTH
FACILITIES AND CONSTRUCTION
1115 SE 164TH AVENUE, DEPT 326
VANCOUVER, WA
PH: 360-729-1870
CONTACT:
SCOTT TANG
CONSTRUCTION PROJECT MANAGER
LANDSCAPE ARCHITECT:
SCHIRMER SATRE GROUP
375 WEST 4TH AVENUE, SUITE 201
EUGENE, OR 97401
PH: 541-686-4540
FX: 541-686-4577
CONTACT:
RICK SATRE, AICP, ASLA, CSI
ARCHITECT:
2FORM ARCHITECTURE
121 LAWRENCE STREET
EUGENE, OR 97401
PH: 541-342-5777
FX: 541-342-6128
CONTACT:
RICHARD SHUGAR, AIA
KIRA MALONE, AIA
CIVIL ENGINEER:
KPFF CONSULTING ENGINEERINGS
1201 OAK STREET, SUITE 100
EUGENE, OR 97401
PH: 541-684-4902
CONTACT:
MATT KEENAN P.E.
STRUCTURAL ENGINEER:
MARQUESS & ASSOCIATES, INC.
1120 EAST JACKSON ST.
MEDFORD, OR 97504
PH: 541-772-7115
CONTACT:
PIETER SMEENK, S.E.
MEP & FIRE PROTECTION:
MARQUESS & ASSOCIATES, INC.
1120 EAST JACKSON ST.
MEDFORD, OR 97504
PH: 541-772-7115
CONTACT:
OSCAR J. ZUNIGA JR., MSC, P.E.
PROJECT DESCRIPTION
SUMMARY:
SINGLE STORY GUEST HOUSE AND RONALD MCDONALD HOUSE WITH ADMINISTRATIVE
SPACES, COMMUNAL SPACES AND 20 GUEST ROOMS. LOCATED AT THE PEACEHEALTH
SACRED HEART MEDICAL CENTER AT RIVERBEND. THIS GUEST HOUSE WILL BE A PLACE
FOR FAMILIES OF SICK PATIENT'S TO STAY WHILE THE PATIENT IS BEING TREATED AT THE
HOSPITAL
TRANSIENT CONGREGATE LIVING FACILITY
R-1. A-2, A-3 OCCUPANCIES
20,208 SF, 1 STORY
TYPE V-B CONSTRUCTION - WOOD FRAME, UNPROTECTED
116 ST. JOSEPH PLACE
SPRINGFIELD, OR 97477
MAP: 17032200
TAX LOT: 100 AND 200
LOT SIZE: 4.59 ACRES
BUILDING SURFACE COVERAGE: 20,208 SF FOOTPRINT/198,354 SF LOT = 10.2%
ZONING: MEDIUM DENSITY RESIDENTIAL
VEHICLE PARKING: 20 SPACES REQUIRED, 22 SPACES PROVIDED (20 STANDARD +2
ADA)
BIKE PARKING: 3 LONG TERM SPACES REQUIRED, 4 LONG TERM & 4 SHORT TERM
PROVIDED
ROOM
150 SF
KEYNOTE REFERENCE
DETAIL REFERENCEX
A50X
X
A30XSECTION REFERENCE
A20XELEVATION REFERENCE
DOOR TAG
X
X WALL TAG
WINDOW TAG
ROOM TAG
X
A40X INTERIOR ELEVATION REFERENCEX
X
2X6 WALL
2X4 WALL
CONCRETE WALL
DRAWING LEGEND
30
A-2 / A-3
BUILDING HEIGHT
(PER TABLE 503)
NUMBER OF STORIES
(PER TABLE 503)
AUTOMATIC SPRINKLER
INCREASE (PER 504.2)
ALLOWED
40' + 20' (PER
504.2) = 60'
1 + 1 (PER 504.2)
YES
PROPOSED
1
YES
24'-2"
FRONTAGE 184'-11 1/4" 349'-2" 160'-11" 311'-11 1/4"
NORTH EAST SOUTH WEST
FRONTAGE INCREASE FACTORS
1 20,208 SF
FLOOR AREA PROPOSED
AREA BY FLOOR (PER 506)
LEVEL FLOOR AREA ALLOWED
27,240 SF
FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING
ELEMENTS (TABLE 601)
BUILDING ELEMENT REQUIRED PROPOSED
CONSTRUCTION
TYPETYPE V-B TYPE V-B
STRUCTURAL
FRAME
BEARING WALLS - EXTERIOR
INTERIOR
NONBEARING WALLS AND
PARTITIONS - INTERIOR
0 0
FLOOR CONSTRUCTION
ROOF CONSTRUCTION
0
0
0
0
0 0
0 0
0 0
FIRE SEPARATION
DISTANCE PROVIDED
NONBEARING WALLS -
EXTERIOR
>30'
NORTH
>30'
SOUTH WEST
>30'
EAST
>30'
FIRE RESISTANCE RATING REQUIREMENTS FOR EXTERIOR
WALLS BASED ON FIRE SEPARATION DISTANCE (TABLE 602)
0 0 0 0
FIRE SEPARATION
DISTANCE PROVIDED
AREA ALLOWED
>30'
NORTH
>30'
SOUTH WEST
>30'
EAST
>30'
NO
LIMIT
MAXIMUM AREA OF EXTERIOR WALL OPENINGS (TABLE 705.8),
BUILDING SPRINKLERED
NO
LIMIT
NO
LIMIT
NO
LIMIT
AREA PROPOSED N/A N/A N/A N/A
FIRE PROTECTION ELEMENTS
REQ'D PROV'D TYPE/CLASS
AUTOMATIC
SPRINKLER SYSTEMPER 504.2 YES
903.1.1 AND
NFPA 13
STANDPIPE SYSTEM NO NO N/A
FIRE ALARM SYSTEM PER 907.2.8 YES NFPA 72
SMOKE DETECTION
SYSTEM PER 907.2.10.2 YES NFPA 72
CO DETECTION
SYSTEMPER 908.7.2 YES 908.7.2
BUILDING EXITS BY FLOOR (TABLE 1021.1)
LEVELOCCUPANT
LOAD
EXITS
REQUIRED
EXITS
PROVIDED
1 295 (<500) 2 6
ILLUMINATED EXIT SIGNS (1011.1)
EXITS ACCESS ILLUMINATION
(1006.1)
EXIT TRAVEL DISTANCE
(TABLE 1016.2)
COMMON PATH OF EGRESS LIMIT
(1014.3)
EXIT SEPARATION DISTANCE
(1015.2.1)
AT EXITS
1FC AT
FLOOR
250'
MAX
75'
MAX
1/3 DIAGONAL
OF SPACE
YES
YES
YES
SEE
PLANS
SEE
PLANS
REQUIRED PROVIDED
MECHANICAL VENTILATION FOR
TOILET AND BATH ROOMS PER
1203.4.2.1
PER OMSC
SEE M0
SERIES
FOR AIR
BALANCE
REQUIRED PROVIDED
6'-0"
18'-7"
84' TRAVEL
DISTANCE
TO EXIT
90'-6" TRAVEL
DISTANCE
TO EXIT
62' TRAVEL
DISTANCE
TO EXIT
87" TRAVEL
DISTANCE
TO EXIT120' TRAVEL
DISTANCE
TO EXIT
90' TRAVEL
DISTANCE
TO EXIT
82' TRAVEL
DISTANCE
TO EXIT
82' TRAVEL
DISTANCE
TO EXIT
EXIT PATH REQUIRING EMERGENCY
BACKUP LIGHTS (PROVIDE AT LEAST
1 FOOTCANDLE
AT THE WALKING SURFACE,
MAINTAINED FOR AT LEAST 90 MIN.)
EXIT TRAVEL DISTANCE: MAXIMUM
TRAVEL DISTANCE TO NEAREST EXIT.
EXIT TRAVEL DISTANCE NOT TO
EXCEED 250'
82" TRAVEL
DISTANCE
TO EXIT
DEA
D E
ND
CO
RR
IDO
R40
'-8
1/2"
MAXIMUM DEAD END CORRIDOR
ALLOWABLE: 50'
DEA
D E
ND
CO
RR
IDO
R
40
'-9
1/4
"
82' TRAVEL
DISTANCE
TO EXIT
R-1
A-2 A-2
R-1
A-3
86'-6" TRAVEL
DISTANCE
TO EXIT
LEGEND
1/2 HOUR FIRE RATED PARTITION
2FORM ARCHITECTURE EXPRESSLY
RESERVES ITS COMMON LAW
COPYRIGHT AND OTHER
PROPERTY RIGHTS IN THESE
PLANS. THESE PLANS ARE NOT TO
BE REPRODUCED, CHANGED, OR
COPIED IN ANY FORM OR MANNER
WHATSOEVER, NOR ARE THEY TO
BE ASSIGNED TO A THIRD PARTY
WITHOUT FIRST OBTAINING THE
WRITTEN PERMISSION AND
CONSENT OF 2FORM
ARCHITECTURE. IN THE EVENT OF
AN UNAUTHORIZED REUSE OF THESE
PLANS BY A THIRD PARTY, THE
THIRD PARTY SHALL HOLD 2FORM
ARCHITECTURE HARMLESS.
PROJECT TITLE
REVISIONS
SYM DATE REFERENCE
DRAWING BY:
REVIEWED BY:
PROJECT NO.
DATE:
DRAWING TITLE
DRAWING NUMBER
R. SHUGAR
A
R
C
H
I
T
E
C
T
U
R
E
121 Lawrence St. Eugene OR 97401
www.2−form.com
p. 541.342.5777f. 541.342.6128
HE
AR
TF
EL
T G
UE
ST
HO
US
E
PERMIT SET
Author
17000
2/6/2018
GENERAL NOTES
G001
PE
AC
EH
EA
LT
H S
AC
RE
D H
EA
RT
ME
DIC
AL C
EN
TE
R A
T R
IVE
RB
EN
D
116 S
T.
JO
SE
PH
PLA
CE
, S
PR
ING
FIE
LD
, O
R
SHEET LIST
SHEET # SHEET NAME
ARCHITECTURE, CONT.
A411 SPECIALTY CASEWORK DETAILS
A412 INTERIOR DOOR DETAILS
A501 FOUNDATION & SITE DETAILS
A502 ROOF DETAILS
A503 ROOF DETAILS
A504 ROOF DETAILS
A505 WINDOW DETAILS
A506 DETAILS
A507 DETAILS
A508 DETAILS
A509 EXTERIOR DOOR DETAILS
A601 DOOR SCHEDULE
A602 FINISH & EQUIPMENT SCHEDULES
STRUCTURAL
S001 STRUCTURAL GENERAL NOTES
S002 SPECIAL INSPECTION PROGRAM
S201 FOUNDATION PLAN
S202 ROOF FRAMING PLAN
S301 FOUNDATION DETAILS
S302 WOOD FRAMING DETAILS
S401 TRUSS AND FRAME SECTIONS
MECHANICAL
M001 LEGEND, NOTES, AND SYMBOLS
M301 HVAC FLOOR PLAN
M501 HVAC SCHEDULES
M601 VRV PIPING SCHEMATIC
M602 HVAC DETAILS
ELECTRICAL
E001 ELECTRICAL GENERAL NOTES
E002 ELECTRICAL DETAILS
E003 ELECTRICAL DETAILS
E004 ELECT. DETAILS & PANEL SCHEDULES
E101 ELECTRICAL SITE PLAN
E201 ELECTRICAL LIGHTING PLANS
E301 ELECTRICAL POWER & SIGNAL PLANS
E302 MECH. EQUIPMENT CIRCUITING PLAN
PLUMBING
P001 PLUMBING NOTES & SCHEDULES
P300 PLUMBING UNDER FLOOR PLAN
P301 PLUMBING FLOOR PLAN
P400 SANITARY WASTE AND VENT RISER
DIAGRAM
P401 DOMESTIC COLD WATER PLAN - WEST
P402 DOMESTIC COLD WATER PLAN - EAST
SHEET LIST
SHEET # SHEET NAME
GENERAL
G001 GENERAL NOTES
CIVIL
C100 CIVIL NOTES & ABBREVIATIONS
C101 EXISTING CONDITIONS PLAN
C200 HORIZONTAL CONTROL & PAVING PLAN
C201 HORIZONTAL CONTROL & PAVING PLAN
C202 RAMP PAVING & GRADING PLAN
C300 UTILITY PLAN
C301 UTILITY PLAN
C400 GRADING PLAN
C401 GRADING PLAN
C500 CIVIL DETAILS
C501 CIVIL DETAILS
C502 CIVIL DETAILS
C503 CIVIL DETAILS
LANDSCAPE
L2.0 SITE PLAN
L3.0 PLANTING PLAN
L4.0 IRRIGATION PLAN
L6.0 DETAILS
L6.1 DETAILS
ARCHITECTURE
A100 ASSEMBLY SCHEDULE
A101 GROUND FLOOR PLAN
A102 FINISH PLAN
A103 REFLECTED CEILING PLAN
A104 ENLARGED REFLECTED CEILING PLAN
A105 ROOF PLAN
A201 EXTERIOR ELEVATIONS
A202 EXT. ELEV. & WINDOW SCHEDULE
A301 BUILDING SECTIONS
A302 BUILDING SECTIONS
A303 BUILDING SECTIONS
A400 ACCESSIBLE MOUNTING HEIGHTS
A401 INTERIOR ELEVATIONS
A402 INTERIOR ELEVATIONS
A403 ENLARGED PLANS & INTERIOR ELEVATIONS
A404 ENLARGED PLANS & INTERIOR ELEVATIONS
A405 TYPICAL INTERIOR DETAILS
A406 SLAT WALL DIAGRAMS
A407 SPECIALTY INTERIOR DETAILS
A408 SPECIALTY INTERIOR DETAILS
A409 CASEWORK DETAILS
A410 SPECIALTY CASEWORK DETAILS
EXTERIOR RENDERING
VICINITY MAP
APPLICABLE CODES
2014 OREGON STRUCTURAL SPECIALTY CODE (OSSC)
2014 OREGON FIRE CODE (OFC)
2014 OREGON MECHANICAL SPECIALTY CODE (OMSC)
2014 OREGON PLUMBING SPECIALTY CODE (OPSC)
2014 OREGON ELECTRICAL SPECIALTY CODE (OESC)
2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE (OEESC)
2009 ICC A117.1
OCCUPANCY AND USE
APPLICABLE OCCUPANCY CLASSIFICATION GROUPS:
A-2: DINING FACILITIES AND ASSOCIATED COMMERCIAL KITCHENS
A-3: COMMUNITY HALLS, LIBRARY, WAITING AREAS
R-1: TRANSIENT CONGREGATE LIVING FACILITIES
SPECIAL REQUIRMENTS
SEPARATION WALLS (PER 420.2)
WALLS SEPARATING DWELLING UNITS AND DWELLING UNITS FROM
OTHER CONTIGUOUS OCCUPANCIES SHALL BE CONSTRUCTED AS A FIRE
PARTITION PER SECTION 708. CORRIDOR WALLS SHALL BE
CONSTRUCTED AS A FIRE PARTITION PER SECTION 708.
AUTOMATIC SPRINKLER SYSTEM (PER 420.5)
GROUP R OCCUPANCIES SHALL BE EQUIPPED THROUGHOUT WITH
AN AUTOMATIC SPRINKLER SYSTEM PER SECTION 903.2.8.
903.2.8: AN AUTOMATIC SPRINKLER SYSTEM SHALL BE INSTALLED IN
ACCORDANCE WITH SECTION 903.3 FOR ALL BUILDINGS WITH A GROUP
R FIRE AREA.
903.3.1.2: AUTOMATIC SPRINKLER SYSTEMS IN GROUP R OCCUPANCIES
UP TO AND INCLUDING FOUR STORIES IN HEIGHT SHALL BE PERMITTED
TO BE INSTALLED THROUGHOUT IN ACCORDANCE WITH NFPA 13-R.
NOTE: PROJECT TO COMPLY WITH NFPA-13 TO OBTAIN SPRINKLER
FLOOR AREA BONUS.
SMOKE DETECTION AND FIRE ALARMS (PER 420.6)
FIRE ALARM SYSTEMS AND SMOKE ALARMS SHALL BE PROVIDED IN
GROUP R-1 OCCUPANCIES PER SECTIONS 907.2.8. SMOKE ALARMS
SHALL BE PER SECTION 907.2.11.
BUILDING HEIGHT AND AREA
ALLOWABLE HEIGHT (PER 503 AND 504)
BUILDING CONST. TYPE: V-B
OCCUPANCIES: NON-SEPARATED:
MOST RESTRICTIVE ALLOWANCES APPLY = A-2/A-3
ALLOWABLE AREA PER FLOOR (PER 506)
BUILDING CONST. TYPE: V-B
OCCUPANCIES: NON-SEPARATED:
MOST RESTRICTIVE ALLOWANCES APPLY = A-2/A-3
A-2 / A-3: AA = 6,000 SF
BUILDING FRONTAGE (506.2, EQUATION 5.2)
(F) TOTAL FRONTAGE: 1006'-11.5"
(P)PERIMETER: 1279'-11.5"
(W) OPEN SPACE WIDTH: 30'
IF = [(F/P) - 0.25] (W/30) IF = [(1006.96/1279.96) - 0.25] (30/30]
FRONTAGE INCREASE FACTOR: IF = 0.54
AUTOMATIC SPRINKLERS (506.3)
BUILDING IS PROVIDED WITH NFPA 13 SPRINKLER SYSTEM PER
903.3.1, ONE STORY. (SPRINKLER SYSTEM IS PROVIDED ABOVE
MINIMUM REQUIREMENT OF 903.3.1.2)
SPRINKLER INCREASE FACTOR: IS =3.0
ALLOWABLE AREA PER STORY
AA= ALLOWABLE AREA PER STORY
AT = TABULAR AREA PER STORY (TABLE 503)
IF = FRONTAGE INCREASE FACTOR
IS = SPRINKLER INCREASE FACTOR
AA = AT + (AT X IF) + (AT X IS)
AA = 6,000 + (6,000 X 0.54) + (6,000 X 3)
ALLOWABLE AREA PER STORY: AA = 27,240 SF
420.2: SEPARATION WALLS: WALLS SEPARATING DWELLING UNITS AND
DWELLING UNITS FROM OTHER CONTIGUOUS OCCUPANCIES SHALL BE
CONSTRUCTED AS A FIRE PARTITION PER SECTION 708. CORRIDOR
WALLS SHALL BE CONSTRUCTED AS A FIRE PARTITION PER SECTION
708.
508.3.3: NON SEPARATED OCCUPANCIES: SEPARATIONS BETWEEN
SLEEPING UNITS AND ACCESSORY USES SHALL BE 1/2-HOUR FIRE
RATED IN SPRINKLERED TYPE V-B CONSTRUCTION.
708.3: FIRE PARTITIONS SHALL HAVE A FIRE-RESISTANCE RATING OF
NOT LESS THAN 1 HOUR.
708.4: CONTINUITY: THE SUPPORTING CONSTRUCTION OF FIRE
PARTITIONS SHALL BE PROTECTED TO AFFORD THE RATING OF THE
WALL SUPPORTED EXCEPT FOR WALLS SEPARATING SLEEPING UNITS
AND CORRIDOR WALLS IN BUILDINGS OF TYPE V-B CONSTRUCTION.
TABLE 1018.1: CORRIDOR IN SPRINKLERED R OCCUPANCY ARE
PERMITTED TO BE 1/2-HOUR FIRE RATED.
MEANS OF EGRESS
EGRESS WIDTH (PER 1005)
1008.1.1 SIZE OF DOORS: SUFFICIENT FOR THE OCCUPANT LOAD
THEREOF AND PROVIDING A MINIMUM 32" CLEAR.
TABLE 1018.2 - CORRIDOR WIDTH: CORRIDORS = 44" MIN.
EGRESS WIDTH (PER 1005)
OTHER EGRESS REQUIREMENTS
ACCESSIBILITY
THE DESIGN COMPLIES WITH THE FOLLOWING PROVISIONS AS
APPLICABLE:
BUILDING CODE NOTED HERE: OSSC CHAPTER 11
ADA ACCESSIBILITY GUIDELINES FOR BUILDINGS AND FACILITIES
(ADAAG): AS AMENDED THROUGH 2010
1107.6.1.1 GROUP R-1 ACCESSIBLE UNITS TO BE PROVIDED PER TABLE
1107.6.1.1. 1 TO 25 UNITS = 1 MINIMUM ACCESSIBLE UNIT W/O ROLL-IN
SHOWERS
11076.1.2 GROUP R-1 TYPE B UNITS: IN STRUCTURES WITH FOUR OR MORE
SLEEPING UNITS INTENDED TO BE OCCUPIED AS A RESIDENCE, EVERY
SLEEPING UNIT SHALL BE A TYPE B UNIT
INTERIOR ENVIRONMENT
ENERGY EFFICIENCY
THIS DESIGN COMPLIES WITH THE PRESCRIPTIVE METHOD AND
SIMPLIFIED TRADE OFF METHOD PER 2010 OEESC.
PLUMBING SYSTEMS
COMMON AREAS: USE OFFICE AND STAFF AREA SQUARE FOOTAGE
B= 1,859 SF /100 = 19 OCC.
WATER CLOSETS: 1 PER 25 FOR THE FIRST 50: 1 PER GENDER PROVIDED
LAVATORIES: 1 PER 40 FOR THE FIRST 80: 1 PER GENDER PROVIDED
R-1: WATER CLOSETS: 1 PER SLEEPING UNIT / PROVIDED
LAVATORIES: 1 PER SLEEPING UNIT / PROVIDED
TUBS / SHOWERS: 1 PER SLEEPING UNIT / PROVIDED
A-2/A-3: 1 DRINKING FOUNTAIN/BOTTLE REFILLER PROVIDED
FIRE AND SMOKE PROTECTION
OCCUPANT LOAD CALCULATIONS
GROUND FLOOR:
RESIDENTIAL: 10,843 SF / 200 GROSS = 55 OCC.
ASSEMBLY (UNCONC.): 3,041 SF / 15 NET = 203 OCC.
BUSINESS: 1859 SF / 100 GROSS = 19 OCC.
COMMERCIAL KITCHEN: 514 SF / 200 GROSS = 3 OCC.
LIBRARY: 490 SF / 50 NET = 10 OCC.
ACCESSORY STORAGE: 1,205 SF / 300 GROSS = 5 OCC.
TOTAL OCCUPANT LOAD: 295 OCC.
LIFE SAFETY PLAN
CONSTRUCTION, CONT.
CONSTRUCTION
1
1 3.2.18 ADDENDUM 1