Page 1: STANDARD PRODUCT CATALOGUE

STANDARD PRODUCT CATALOGUE

AIR CONDITIONING

COMMERCIAL REFRIGERATION

HEAT PUMP

Brochure_Standard_English_02.indd 1 27/5/15 11:17

Page 2: STANDARD PRODUCT CATALOGUE

“Strive for perfection, Pursuit of excellence”

Sanhua is a leading HVAC&R manufacturer of controls and components with a global footprint and 30 years of experience. Our co-operation with the largest companies in the Automotive,

Appliance and HVAC&R industry makes Sanhua a leading worldwide OEM supplier providing the highest quality components at the most competitive price.

CHILLING IDEAS

WORLDWIDE

SUMMARY4 WAY REVERSING VALVE SHF series4 WAY REVERSING VALVE SHF (HP) seriesPRESSURE SENSOR YCQ series

ELECTRONIC EXPANSION VALVE DPF-T/S seriesSOLENOID VALVE MDF seriesSOLENOID VALVE FDF N/C seriesSOLENOID VALVE FDF N/O series

THERMOSTATIC EXPANSION VALVE RFKA series THERMOSTATIC EXPANSION VALVE RFGD seriesBALL VALVE SBV series CHECK VALVE PISTON TYPE YCV series

SIGHT GLASS SYJ series BRASS SERVICE VALVE SSV series CHARGE VALVE TCJ series

UNI-FLOW FILTER DRIER DTG/L series BI-FLOW FILTER DRIER STG/L series COPPER FILTER DRIER BGQ seriesFILTER DRIER WITH REPLACEABLE CORE HTG series

Brochure_Standard_English_02.indd 2 27/5/15 11:17

Page 3: STANDARD PRODUCT CATALOGUE

SHF (HP) SERIES

4 WayReversing Valve

SHF series four-way reversing valves are applicable for heat pump systems such as central, unitary and room air conditioners to realize switching between cooling mode and heating mode by changing the flow path of refrigerant.

SHF (HP) series four-way reversing valves are designed especially for usage in heat pump systems to realize switching between cooling mode and heating mode by changing the flow path of the refrigerant.

COIL

Part Number

Max working temp.

Power Supply

Rated Voltage

[°C] [-] [V]SHF-56001 130 AC 220 to 240SHF-56002 130 AC 200SHF-56003 130 AC 100SHF-56004 130 AC 110 to 120SHF-56005 130 AC 24SHF-56006 130 AC 265 to 277SHF-56024 130 AC 220SHF-56025 130 AC 110 to 120SHF-56009 130 AC 24SHF-56012* 155 AC 220 to 240SHF-56013* 155 AC 220SHF-56014* 155 AC 120SHF-56015* 155 AC 100 to 110SHF-56016* 155 AC 24SHF-56017* 155 AC 265 to 277SHF-56018* 155 AC 200SHF-56019* 155 DC 12SHF-56020* 155 DC 24SHF-56021 130 AC 100SHF-56022 130 AC 200SHF-56023 130 DC 12SHF-56027 130 AC 220 to 240

REFRIGERANTR22, R134a, R404A, R407C, R410A, R507A

OPD MAX 40 bar

LARGE TEMPERATURE SERVICE RANGE -30°C to +135°C

PS45 bar

Nominal operating conditions Condition 2

Condensing Temperature t_c 54°CEvaporating Temperature t_o 7,2°C

SuperHeating dt_oh 5KSubCooling dt_u 5K

Part Number

Nominal Capacity (condition 2)

Kv (m3/h)

Connections Size ODFR407C R410A R134a R404A/R507A

ΔP:0,1 bar

ΔP:0,2 bar

ΔP:0,1 bar

ΔP:0,2 bar

ΔP:0,1 bar

ΔP:0,2 bar

ΔP:0,1 bar

ΔP:0,2 bar D tube Ø

[in]E/S/C Tube

Ø [in][kW] [kW] [kW] [kW] [kW] [kW] [kW] [kW]SHF-19005 3,4 4,8 4,0 5,7 2,7 3,9 2,7 3,9 1,7 5/16 3/8 SHF-19006 6,4 9,0 7,5 10,6 5,1 7,2 5,1 7,2 3,1 3/8 1/2 SHF-50022 20,2 28,5 23,6 33,4 16,1 22,8 16,1 22,7 9,9 1/2 3/4 SHF-50023 29,7 42,0 34,8 49,2 23,7 33,5 23,7 33,5 14,7 3/4 7/8

SHF SERIES

* This selection range is compatible for both series SHF and SHF (HP), except SHF-56018 only to SHF (HP)

Capacity under other condition available on our website

Please visit our website www.sanhuaeurope.com and link to the technical information section to find the complete information of every product.

DECLARATION OF CONFORMITY:

Pressure Equipment Directive 97/23/EC

RoHS PED & UL, VDE

Part Number

Nominal Capacity (condition 2)

Kv(m3/h)

Connections Size ODFR407C R410A R134a R404A/R507A

ΔP:0,1 bar

ΔP:0,2 bar

ΔP:0,1 bar

ΔP:0,2 bar

ΔP:0,1 bar

ΔP:0,2 bar

ΔP:0,1 bar

ΔP:0,2 bar D tube

Ø [in]E/S/C

Tube Ø [in][kW] [kW] [kW] [kW] [kW] [kW] [kW] [kW]SHF-19001 3,4 4,8 4,0 5,7 2,7 3,9 2,7 3,9 1,7 5/16 3/8 SHF-19002 6,4 9,0 7,5 10,6 5,1 7,2 5,1 7,2 3,1 3/8 1/2 SHF-19003 7,3 10,3 8,5 12,0 5,8 8,2 5,8 8,2 3,6 3/8 5/8 SHF-19004 9,2 13,0 10,8 15,2 7,4 10,4 7,3 10,4 4,5 1/2 5/8 SHF-50001 12,7 17,9 14,8 21,0 10,1 14,3 10,1 14,3 6,3 1/2 3/4 SHF-50002 12,7 17,9 14,8 21,0 10,1 14,3 10,1 14,3 6,3 1/2 7/8 SHF-50003 12,7 17,9 14,8 21,0 10,1 14,3 10,1 14,3 6,3 5/8 7/8

SHF-50004 16,0 22,6 18,7 26,5 12,8 18,0 12,7 18,0 7,9 1/2 3/4

SHF-50005 16,0 22,6 18,7 26,5 12,8 18,0 12,7 18,0 7,9 1/2 7/8

SHF-50006 16,0 22,6 18,7 26,5 12,8 18,0 12,7 18,0 7,9 5/8 7/8 SHF-50007 16,0 22,6 18,7 26,5 12,8 18,0 12,7 18,0 7,9 3/4 7/8 SHF-50008 20,2 28,5 23,6 33,4 16,1 22,8 16,1 22,7 9,9 1/2 3/4 SHF-50009 28,2 39,8 33,0 46,6 22,5 31,8 22,4 31,7 13,9 1/2 7/8 SHF-50010 28,2 39,8 33,0 46,6 22,5 31,8 22,4 31,7 13,9 5/8 7/8 SHF-50011 28,2 39,8 33,0 46,6 22,5 31,8 22,4 31,7 13,9 5/8 1 1/8SHF-50012 28,2 39,8 33,0 46,6 22,5 31,8 22,4 31,7 13,9 3/4 7/8SHF-50013 28,2 39,8 33,0 46,6 22,5 31,8 22,4 31,7 13,9 3/4 1 1/8

SHF-50014 28,2 39,8 33,0 46,6 22,5 31,8 22,4 31,7 13,9 7/8 1 1/8

SHF-50015 29,7 42,0 34,8 49,2 23,7 33,5 23,7 33,5 14,7 3/4 7/8SHF-50016 37,5 53,1 43,9 62,1 30,0 42,4 29,9 42,3 18,5 1 1/8 1 3/8SHF-50017 57,9 81,9 67,7 95,8 46,2 65,3 46,1 65,2 28,5 1 1 1/4SHF-50024 57,9 81,9 67,7 95,8 46,2 65,3 46,1 65,2 28,5 1 1 1/4SHF-50018 82,2 116,3 96,2 136,1 65,6 92,8 65,5 92,7 40,5 1 1/4 1 1/2SHF-50025 82,2 116,3 96,2 136,1 65,6 92,8 65,5 92,7 40,5 1 1/4 1 1/2SHF-50019 118,4 167,4 138,5 195,9 94,5 133,6 94,3 133,4 58,4 1 1/2 1 3/4SHF-50020 143,1 202,3 167,4 236,7 114,2 161,5 114,0 161,2 70,5 1 1/2 2 1/8SHF-50021 171,2 242,1 200,3 283,3 136,6 193,2 136,5 193,0 84,4 1 5/8 2 5/8SHF-50031 280,7 397,0 328,5 464,6 224,0 316,8 223,7 316,4 138,4 2 1/8 2 5/8SHF-50032 359,1 507,9 420,2 594,3 286,6 405,3 286,2 404,8 177,0 2 5/8 3 1/8

“Strive for perfection, Pursuit of excellence”

Pressure Sensor

Pressure sensors are widely used in Air Conditioning, Refrigeration and Heat Pump system. Using a 5 V excitation input these sensors provide a 0.5-3.5 V or 0.5-4.5 V signal output proportional to the pressure of the medium. This device requires no end user amplification. Pressure sensors permit to control and guarantee the system working under safe and stability condition.

YCQ SERIES

DECLARATION OF CONFORMITY:

Pressure Equipment Directive 97/23/EC

GENERAL CHARACTERISTICS

Note: 1) Signal span: VFS=FS (Full Scale) = VA(pr) - VA0

2) Accuracy measured within the temperature ranges:- YCQB02xxx: from -30°C to +85°C- YCQB05xxx: from -30°C to +120°C Included Nonlinearity (L) and pressure hysteresis. The Nonlinearity is the deviation of the real sensor characteristic VA = f(p) from the ideal straight line. It can be approximated by a polynomial of second order, with the maximum at px = pr / 2. The equation to calculate the nonlinearity is: L = (VA(px) – VA0) / (VA(pr) – VA0) – px / pr

3) Response Time: delay between a pressure change (10 to 90% pr) and the corresponding signal output change (10 to 90% FS)4) Insulation Resistance measured with rated voltage: 500 V DC

*Note: 0.8% FS accuracy is guaranteed only in the temperature range -40°C /+40°C

REFRIGERANTR22, R134a, R404A, R407C, R410A, R507A

MEDIUM TEMPERATURE TS MIN./MAX.: -40°C / +120°C (models with 0.8% accuracy)*

AMBIENT TEMPERATURE MIN./MAX.: -30°C / +80°

MEDIUM TEMPERATURE TS MIN./MAX.: -30°C / +120°C (models with 2% accuracy)

Models with 2% AccuracyModel YCQB02H01 YCQB05H01 YCQB02L01 YCQB05L01Part Number YCQ-21001 YCQ-21002 YCQ-21003 YCQ-21004Connection Type Solder Solder Thread ThreadConnection Pipe Size [ inch ] 1/4" 1/4" SAE - 1/4" SAE - 1/4"Thread Size [ inch ] - - 7/16-20 UNF 7/16-20 UNFSupply Voltage [ V ] 5 ± 0,25 DC 5 ± 0,25 DC 5 ± 0,25 DC 5 ± 0,25 DCPressure Range (0 to pr) [ MPa ] 0 to 2 0 to 5 0 to 2 0 to 4,6Output (VA0 to VApr) [ V ] 0,5 to 3,5 DC 0,5 to 3,5 DC 0,5 to 4,5 DC 0,5 to 4,5 DCSignal Span (VFS) 1 [ V ] 3,0 3,0 3,0 3,0Accuracy 2 [ % ] ± 2,0 % F.S. ± 2,0 % F.S. ± 2,0 % F.S. ± 2,0 % F.S.Response Time 3 [ ms ] 10 10 10 10Current Consumption [ mA ] Max. 10 Max. 10 Max. 10 Max. 10Load Resistance [ kΩ ] Min. 10 Min. 10 Min. 10 Min. 10Insulation Resistance 4 [ MΩ ] Max. 100 Max. 100 Max. 100 Max. 100Maximum Operating Pressure (MOP) [ MPa ] 3,50 5,00 3,50 4,60Test Pressure [ MPa ] 5,25 7,50 5,25 7,50Burst Pressure [ MPa ] 17,50 25,00 17,50 25,00Protection Class [ - ] IP 66 IP 66 IP 66 IP 66

Models with 0.8% AccuracyModel YCQB02H01-1 YCQB02L01-1Part Number YCQ-21005 YCQ-21006Connection Type Solder ThreadConnection Pipe Size [ inch ] 1/4" SAE - 1/4"Thread Size [ inch ] - 7/16-20 UNFSupply Voltage [ V ] 5 ± 0,25 DC 5 ± 0,25 DCPressure Range (0 to pr) [ MPa ] 0 to 2 0 to 2Output (VA0 to VApr) [ V ] 0,5 to 3,5 DC 0,5 to 4,5 DCSignal Span (VFS) 1 [ V ] 3,0 3,0Accuracy 2 [ % ] ± 0,8 % F.S. ± 0,8 % F.SResponse Time 3 [ ms ] 10 10Current Consumption [ mA ] Max. 10 Max. 10Load Resistance [ kΩ ] Min. 10 Min. 10Insulation Resistance 4 [ MΩ ] Max. 100 Max. 100Maximum Operating Pressure (MOP) [ MPa ] 3,50 3,50Test Pressure [ MPa ] 5,25 5,25Burst Pressure [ MPa ] 17,50 17,50Protection Class [ - ] IP 66 IP 66

Brochure_Standard_English_02.indd 3 27/5/15 11:17

Page 4: STANDARD PRODUCT CATALOGUE

PS 45 bar

Solenoid Valve

Solenoid Valve

MDF series solenoid valves are direct operated or pilot operated solenoid valves, mainly used in refrigerant control of various devices such as refrigerating and freezing systems, air conditioners and heat pumps.

REFRIGERANTR22, R134a, R404A, R407C, R410A, R507A

REFRIGERANTR22, R134a, R407C, R404A, R410A, R507A

PS45 bar

LARGE TEMPERATURE SERVICE RANGE -40°C to +140°C

LARGE TEMPERATURE SERVICE RANGE -30°C to +120°C

COIL PROTECTIONIP65 - DIN Plug

* only for FDF (NO) valve

COIL

MDF SERIES

FDF N/C SERIES

FDF N/O SERIES

Normally Closed. FDF series solenoid valves are direct operated or pilot operated solenoid valves, mainly used in refrigerant control of various devices such as refrigerating and freezing systems, air conditioners and heat pumps.

Normally Open. FDF2AK series solenoid valves are direct operated, normally open solenoid valves, mainly used in refrigerant control of various devices such as refrigerating and freezing systems, air conditioners and heat pumps.

Part number Thread Connection Kv

Actuation [inch] (m³/h)

MDF-08039 1/4 0,16 DirectMDF-08040 1/4 0,23 DirectMDF-08041 3/8 0,23 DirectMDF-08042 3/8 0,8 PilotMDF-08043 1/2 0,8 PilotMDF-08044 1/2 1,9 PilotMDF-08045 5/8 1,9 PilotMDF-08046 5/8 2,6 PilotMDF-08047 7/8 2,6 Pilot

COILPart

Number Rated Voltage [V] Power [W]

MDF-60001 24 AC10,5W (50Hz)

8,5W (60Hz)

MDF-60002 110 to 120 AC12W (50Hz) 10W (60Hz)

MDF-60003 220 to 240 AC12W (50Hz) 10W (60Hz)

MDF-60004 24 DC12W (50Hz) 10W (60Hz)

FDF (N/C)

Part number Kv

Actuation (m³/h)

FDF-06001 0,08 DirectFDF-06002 0,2 PilotFDF-06003 0,26 PilotFDF-06004 0,26 PilotFDF-06005 0,56 PilotFDF-06006 0,95 PilotFDF-06007 2,4 PilotFDF-06008 3,44 Pilot

FDF (N/O)

Part number Kv

Actuation (m³/h)

FDF-06009 0,05 DirectFDF-06010 0,08 Direct

Part Number

Rated Voltage [V] Power [W]

FQA-55001 24 AC5W

(50Hz) 4,5W (60Hz)

FQA-55002 110 to 120 AC5W (50Hz)

4,5W (60Hz)

FQA-55003 220 to 240 AC5W (50Hz)

4,5W (60Hz)

FQA-55007 * 220 to 240 AC6,5W (50Hz) 5W (60Hz)

Please visit our website www.sanhuaeurope.com and link to the technical information section to find the complete information of every product.

CERTIFICATE OF CONFORMITY:

Pressure Equipment Directive 97/23/EC

CERTIFICATE OF CONFORMITY:

Pressure Equipment Directive 97/23/EC

RoHS

RoHSRoHS UL TÜV

Part number Solder Connection Kv

Actuation [inch] (m³/h)

MDF-08001 1/4 0,16 DirectMDF-08002 1/4 0,23 DirectMDF-08003 3/8 0,23 DirectMDF-08004 3/8 0,8 PilotMDF-08005 1/2 0,8 PilotMDF-08006 1/2 1,9 PilotMDF-08007 5/8 1,9 PilotMDF-08027 5/8 2,3 PilotMDF-08009 7/8 2,3 PilotMDF-08010 7/8 5 PilotMDF-08011 1-1/8 5 PilotMDF-08012 7/8 5,9 PilotMDF-08048 1-1/8 5,9 PilotMDF-08013 1-3/8 5,9 PilotMDF-08014 1-1/8 10 PilotMDF-08015 1-3/8 10 Pilot (P)MDF-08016 1-3/8 15 Pilot (P)MDF-08017 1-5/8 15 Pilot (P)MDF-08018 1-5/8 25 Pilot (P)MDF-08019 2-1/8 25 Pilot (P)

Part number Solder Connection Kv

Actuation [mm] (m³/h)

MDF-08020 6 0,16 DirectMDF-08021 6 0,23 DirectMDF-08022 10 0,23 DirectMDF-08023 10 0,8 PilotMDF-08024 12 0,8 PilotMDF-08025 12 1,9 PilotMDF-08007 16 1,9 PilotMDF-08027 16 2,3 PilotMDF-08009 22 2,3 PilotMDF-08010 22 5 PilotMDF-08030 28 5 PilotMDF-08012 22 5,9 PilotMDF-08031 28 5,9 PilotMDF-08013 35 5,9 PilotMDF-08033 28 10 Pilot (P)MDF-08015 35 10 Pilot (P)MDF-08016 35 15 Pilot (P)MDF-08036 42 15 Pilot (P)MDF-08037 42 25 Pilot (P)MDF-08019 54 25 Pilot (P)

ElectronicExpansion Valve

REFRIGERANTR22, R134a, R404A, R407C, R410A, R507A

PS45 bar

LARGE TEMPERATURE SERVICE RANGE -30°C to + 70°C (duty cycle below 50%)

COILPart

Number

Nominal Cooling Capacity (kW)Kv

m3/hR22 R134a R407C R404AR507A R410A

DPF-09001 3,5 2,7 3,5 2,5 4,2 0,05DPF-09002 5,3 4,1 5,3 3,7 6,36 0,08DPF-09003 7 5,4 7 4,9 8,4 0,1DPF-09004 8,8 6,7 8,75 6,1 10,5 0,16DPF-09005 11 8,1 10,5 7,4 12,6 0,2DPF-09006 18 13,5 17,5 12,3 21 0,23DPF-09007 21 16,2 21 14,7 25,2 0,39DPF-09008 28 21,6 28 19,6 33,6 0,43DPF-09010 42 32,3 42 29,4 50,4 0,5DPF-09011 53 40,4 52,5 36,8 63 0,7DPF-09012 70 53,9 70 49,0 84 0,9DPF-09013 105 80,9 105 73,5 126 1,1

Part Number

DPF-58001

DPF-58002

DPF-T/S SERIEST/S series electronic expansion valves are designed for usage in air conditioning and refrigeration systems or in heat pumps. The valve supports automatic adjustment of refrigerant flow rate and makes the system work under optimized conditions for the purpose of fast cooling or heating, precise temperature control and energy saving. The valve can also be used e.g. for suction line pressure controls. These valves provide bidirectional operation to control the refrigerant flow rate in heating or cooling mode.

COIL PROTECTIONIP 66. Insulation Class E

DECLARATION OF CONFORMITY:

Pressure Equipment Directive 97/23/EC

RoHS

Brochure_Standard_English_02.indd 4 27/5/15 11:17

Page 5: STANDARD PRODUCT CATALOGUE

Please visit our website www.sanhuaeurope.com and link to the technical information section to find the complete information of every product.

ThermostaticExpansion Valve

RFKA series thermostatic expansion valves are used to adjust mass flow of refrigerant into the evaporator while controlling the refrigerant´s superheat at the outlet of the evaporator. They can be used for various refrigerants under all working conditions. Possible applications are refrigeration systems like freezers, ice makers, dehumidifiers as well as air conditioners and heat pumps at various evaporation temperature ranges.

Version with Solder ODF in inch sizes for Outlet B and for External Equalization C on request

ORIFICE

PORT CONNECTIONS

REFRIGERANTR22, R134a, R404A, R407C, R507A

PS 35 bar

LARGE TEMPERATURE SERVICE RANGE -40°C to +70°C

CAPILLAR LENGHT1,5 m

RFKA SERIES

Part Number Equivalence

Connection type Outlet size Capacity (kW)Solder (inch)

Refrigerant PSIn/Out/Ext.

flare Solder[inch] [mm]

RFK-24001 TX 2 flare / flare 1/2 - -

R222,8

RFK-24002 TEX 2 flare / flare / flare 1/2 - -RFK-24003 TX 2 flare / solder - 12 -RFK-24004 TEX 2 flare / solder / solder - 12 -RFK-24005 TX 2 flare / solder - - 1/2RFK-24006 TEX 2 flare / solder / solder - - 1/2RFK-24007 TZ 2 flare / flare 1/2 - -

R407C2,8

RFK-24008 TEZ 2 flare / flare / flare 1/2 - -RFK-24009 TZ 2 flare / solder - 12 -RFK-24010 TEZ 2 flare / solder / solder - 12 -RFK-24011 - flare / solder - - 1/2RFK-24012 TEZ 2 flare / solder / solder - - 1/2RFK-24013 TS 2 flare / flare 1/2 - -

R404A / R507

3,5

RFK-24014 TES 2 flare / flare / flare 1/2 - -RFK-24015 TS 2 flare / solder - 12 -RFK-24016 TES 2 flare / solder / solder - 12 -RFK-24017 TS 2 flare / solder - - 1/2RFK-24018 TES 2 flare / solder / solder - - 1/2RFK-24019 TN 2 flare / flare 1/2 - -

R134a2,1

RFK-24020 TEN 2 flare / flare / flare 1/2 - -RFK-24021 TN 2 flare / solder - 12 -RFK-24022 TEN 2 flare / solder / solder - 12 -RFK-24023 TN 2 flare / solder - - 1/2RFK-24024 TEN 2 flare / solder / solder - - 1/2

Valve orificePart number

Nominal Capacity in kW

R22 R407C R404A/R507C R134a

RFK-24036 1,04 1,09 0,76 0,62RFK-24037 1,66 1,7 1,34 1,1RFK-24038 3,5 3,62 3,06 2,18RFK-24039 4,87 5 4,15 2,77RFK-24040 6,82 7,02 6,01 4,07RFK-24041 9,49 9,92 8,73 5,56RFK-24042 14,9 14,8 12,5 8,35RFK-24043 19,9 20,2 15,8 12,0

Inlet A Outlet B External Equalization C

Flare Flare Solder ODF Flare Solder ODF

[inch] [inch] [mm] [inch] [inch] [mm] [inch]

3/81/2 - - 1/4 - -- 12 - - 6 -- - 1/2 - - 1/4

DECLARATION OF CONFORMITY:

Pressure Equipment Directive 97/23/EC

PED EN

RoHS

B B

A A

C

C

SOLDER ADAPTERS

SOLDER ADAPTERS INLET A

SOLDER ADAPTERS FOR EXTERNAL EQUALIZATION C

Product Number SAE Flare e

Solder Connection d

RFK-24044

3/8”

3/8”RFK-24045 10 mmRFK-24048 1/4”RFK-24049 6 mm

Product Number SAE Flare e

Solder Connection d

RFK-24046 1/4” 6 mmRFK-24047 1/4”

FLARE NUTS FOR RFKA

Product Number SAE Flare[inch]

Pipe Diameter Ø d

[mm] [inch]RFK-24050 1/4 6 1/4RFK-24051 3/8 - 3/8RFK-24052 1/2 12 1/2

Brochure_Standard_English_02.indd 5 27/5/15 11:17

Page 6: STANDARD PRODUCT CATALOGUE

Check Valve Piston Type

Piston type check valves are designed for installation in commercial refrigerating systems and in residential or industrial air conditioning plants. They are used to control the unidirectional flow of refrigerant so as to prevent backflow.

YCV SERIES

Part number Type Connection Kv

Ø ODF(m³/h)

[in] [mm]YCV-15001 straight-way - 6 0,56YCV-15002 straight-way 1/4 - 0,56YCV-15007 straight-way 3/8 - 1,43YCV-15008 straight-way 3/8 - 1,43YCV-15009 straight-way - 10 1,43YCV-15010 straight-way - 10 1,43YCV-15015 straight-way - 12 2,1YCV-15016 straight-way - 12 2,1YCV-15017 straight-way 1/2 - 2,1YCV-15018 straight-way 1/2 - 2,1YCV-15021 straight-way 5/8 16 3,9YCV-15022 straight-way 5/8 16 3,9YCV-15027 straight-way - 18 5,52YCV-15028 straight-way - 18 5,52YCV-15029 straight-way 3/4 - 5,52YCV-15030 straight-way 3/4 - 5,52YCV-15051 straight-way 7/8 22 5,52YCV-15052 straight-way 7/8 22 5,52YCV-15033 L-shape 7/8 22 13,2YCV-15034 L-shape 7/8 22 13,2YCV-15039 L-shape - 28 19,02YCV-15040 L-shape - 28 19,02YCV-15041 L-shape 1 1/8 - 19,02YCV-15042 L-shape 1 1/8 - 19,02YCV-15045 L-shape 1 3/8 35 29,1YCV-15046 L-shape 1 3/8 35 29,1YCV-15047 L-shape 1 5/8 - 29,1YCV-15048 L-shape 1 5/8 - 29,1YCV-15049 L-shape - 42 29,1YCV-15050 L-shape - 42 29,1

Ball Valve REFRIGERANTR22, R134a, R404A, R407C, R410A, R507A Bi-directionnal, full port

PS45 bar

LARGE TEMPERATURE SERVICE RANGE -40°C to +120°C

SBV SERIES

Please visit our website www.sanhuaeurope.com and link to the technical information section to find the complete information of every product.

DECLARATION OF CONFORMITY:

Pressure Equipment Directive 97/23/EC

DECLARATION OF CONFORMITY:

Pressure Equipment Directive 97/23/EC

RoHS

RoHS PED & UL

The ball valve of series SBV is applicable for commercial air conditioner, freezing or deep-freezing equipment or other refrigeration circuits in order to open and to shut off inner flow path by operating the valve stem. It can also be used as service valve for vacuum pumping and refrigerant injection etc.

Part Number

Connection ConnectionKv (m3/h)

(inch) (mm)

Without access fittingSBV-13001 - 6 1,9SBV-13002 1/4 - 1,9SBV-13037 3/8 - 5,5SBV-13003 - 10 5,5SBV-13004 - 12 10,2SBV-13005 1/2 - 10,2SBV-13006 - 15 13,2SBV-13007 5/8 16 13,8SBV-13008 - 18 19,5SBV-13009 3/4 - 19,5SBV-13010 7/8 22 28SBV-13011 - 28 51,5SBV-13012 1 1/8 - 51,5SBV-13013 1 3/8 35 80SBV-13038 1 5/8 - 119,8SBV-13014 - 42 119,8SBV-13015 2 1/8 54 225SBV-13016 - 64 225SBV-13017 2 5/8 - 305SBV-13018 3 1/8 80 635SBV-13041 3 5/8 92 805SBV-13046 4 1/8 105 950SBV-13042 4 1/4 108 950

Part Number

Connection ConnectionKv (m3/h)

(inch) (mm)

With access fittingSBV-13019 - 6 1,9SBV-13020 1/4 - 1,9SBV-13039 3/8 - 5,5SBV-13021 - 10 5,5SBV-13022 - 12 10,2SBV-13023 1/2 - 10,2SBV-13024 - 15 13,2SBV-13025 5/8 16 13,8SBV-13026 - 18 19,5SBV-13027 3/4 - 19,5SBV-13028 7/8 22 28SBV-13029 - 28 51,5SBV-13030 1 1/8 - 51,5SBV-13031 1 3/8 35 80SBV-13040 1 5/8 - 119,8SBV-13032 - 42 119,8SBV-13033 2 1/8 54 225SBV-13034 - 64 225SBV-13035 2 5/8 - 305SBV-13036 3 1/8 80 635SBV-13043 3 5/8 92 805SBV-13045 4 1/8 105 950SBV-13044 4 1/4 108 950

Thermostatic Expansion Valve

REFRIGERANTR22, R134a, R404A, R407C, R410A, R507

PS45 bar

LARGE TEMPERATURE SERVICE RANGE -40°C to +70°C

RFGD SERIES

RFGD series thermostatic expansion valves are used to adjust mass flow of refrigerant into the evaporator while controlling the refrigerant´s superheat at the outlet of the evaporator. They can be used for various refrigerants under all working conditions. Typical applications are refrigeration systems like commercial refrigerators and freezers, icemakers, dehumidifiers as well as air conditioners at various evaporation temperatures.

DECLARATION OF CONFORMITY:

Pressure Equipment Directive 97/23/EC

R22 R407C2) R404A / R507A R134a R410A

PS: 2,8 MPa PS: 2,8 MPa PS: 3,5 MPa PS: 2,1 MPa PS: 4,5 MPa

Model Name3)

Capacity Model Name3)

Capacity Model Name3)

Capacity Model Name3)

Capacity Model Name3)

Capacity

[USRT] [kW] [USRT] [kW] [USRT] [kW] [USRT] [kW] [USRT] [kW]

RFGD 01-13,0 10,6

RFGD 02-13,1 10,9

RFGD 03-12,0 7,0

RFGD 04-11,8 6,3

RFGD 05-13,5 12,3

RFGD 01E-1 RFGD 02E-1 RFGD 03E-1 RFGD 04E-1 RFGD 05E-1RFGD 01-2

4,0 14,1RFGD 02-2

4,2 14,8RFGD 03-2

2,8 9,8RFGD 04-2

2,5 8,8RFGD 05-2

4,5 15,8RFGD 01E-2 RFGD 02E-2 RFGD 03E-2 RFGD 04E-2 RFGD 05E-2RFGD 01-3

6,0 21,1RFGD 02-3

6,3 22,2RFGD 03-3

4,2 14,8RFGD 04-3

3,6 12,7RFGD 05-3

7,0 24,6RFGD 01E-3 RFGD 02E-3 RFGD 03E-3 RFGD 04E-3 RFGD 05E-3RFGD 01-4

7,5 26,4RFGD 02-4

8,1 28,5RFGD 03-4

5,4 19,0RFGD 04-4

4,6 16,2RFGD 05-4

8,6 30,2RFGD 01E-4 RFGD 02E-4 RFGD 03E-4 RFGD 04E-4 RFGD 05E-4RFGD 01-5

9,0 31,7RFGD 02-5

9,4 33,1RFGD 03-5

6,4 22,5RFGD 04-5

5,5 19,3RFGD 05-5

10,6 37,3RFGD 01E-5 RFGD 02E-5 RFGD 03E-5 RFGD 04E-5 RFGD 05E-5RFGD 01-6

11,0 38,7RFGD 02-6

11,7 41,1RFGD 03-6

7,8 27,4RFGD 04-6

6,8 23,9RFGD 05-6

12,8 45,0RFGD 01E-6 RFGD 02E-6 RFGD 03E-6 RFGD 04E-6 RFGD 05E-6

TECHNICAL DATA Nominal Capacities 1

Note: 1) Nominal capacities referred at the following working conditions: Condensing temperature: 38°C; evaporating temperature +4,4°C; Liquid temperature 37°C Static Super Heating: 3,5K 2) R407C data based on dew point conditions 3) Model Name in this table is referred to the first 4 positions of the model designation

REFRIGERANTR22, R134a, R404A, R407C, R410A, R507A

PS 46 bar

SOLDER CONNECTION

LARGE TEMPERATURE SERVICE RANGE -50°C to +140°C

Brochure_Standard_English_02.indd 6 27/5/15 11:17

Page 7: STANDARD PRODUCT CATALOGUE

Sight Glass

Charge Valve

Sight glasses are installed after the filter drier in liquid line of refrigerating systems, in order to observe property changes of the refrigerant (liquid/vapour) and to indicate the moisture level by colours.

Charge valves are mainly installed in air conditioning and refrigeration systems. They are used as service valve for circuit evacuation to vacuum and for refrigerant injection.

REFRIGERANTR22, R134a, R404A, R407C, R410A, R507A

PS46 bar

LARGE TEMPERATURE SERVICE RANGE -50°C to +80°C

SYJ SERIES

TCJ SERIES

Brass ServiceValve

REFRIGERANTR134a, R404A, R407C, R410A, R507A

PS45 bar

LARGE TEMPERATURE SERVICE RANGE -30ºC to+120ºC

SSV SERIES Brass service valves of series SSV are applicable for split air conditioners to connect indoor unit and outdoor unit. It can also be used in other cooling or refrigeration systems. The inner path of the valve can be closed by operating the valve stem. The 3way version (with charge port) can be used as service valve for vacuum pumping and refrigerant injection.

Part number Connection

Type

Connections ODF

Ø [in] Ø [mm]SYJ-42001 Solder - 6SYJ-42002 Solder 1/4 -SYJ-42003 Solder 3/8 -SYJ-42004 Solder - 10SYJ-42005 Solder 1/2 -SYJ-42006 Solder - 12SYJ-42007 Solder 5/8 16SYJ-42008 Solder 3/4 -SYJ-42009 Solder 7/8 22

Part number Connection

Type

Connections UNF

[in]SYJ-42010 Flare 1/4 SYJ-42011 Flare 3/8 SYJ-42012 Flare 1/2 SYJ-42013 Flare 5/8 SYJ-42014 Flare 3/4

Part number ØA B ØC ØD

ØIPipe

Charge Port Flare

(in)

Cooling CapacityFlare in mm mm in mm

SSV-14001 7/16-20UNF 23 7,2 1/4 6,35 4,8 - 0,7 - 1,5SSV-14002 5/8-18UNF 24,5 7,2 3/8 9,52 7,0 5/16 0,7 - 3,7SSV-14003 3/4-16UNF 28 7,2 1/2 12,7 10 5/16 1,1 - 7,5SSV-14004 7/8-14UNF 34 7,2 5/8 15,9 12,5 5/16 1,5 - 8,8SSV-14005 1-1/16-14UNS 40 7,2 3/4 19,1 16 5/16 3,7 - 5,9

REFRIGERANTR22, R134a, R404A, R407C, R410A, R507A

PS45 bar

LARGE TEMPERATURE SERVICE RANGE -30ºC to+80ºC

Part number A B C Flare Ø D solder Ø E

mm mm in mm in mm*TCJ-14001 26 65 7/16-20 6,35 1/4 8TCJ-14002 26 65 1/2-20 6,35 1/4 8

*TCJ-14003 26 - 7/16-20 - - -TCJ-14004 26 - 1/2-20 - - -

Please visit our website www.sanhuaeurope.com and link to the technical information section to find the complete information of every product.

DECLARATION OF CONFORMITY:

Pressure Equipment Directive 97/23/EC

DECLARATION OF CONFORMITY:

Pressure Equipment Directive 97/23/EC

DECLARATION OF CONFORMITY:

Pressure Equipment Directive 97/23/EC

RoHS

RoHS PED

RoHS PED *Only for R22

MALE / MALE

FEMALE / FEMALE

Partnumber

Connection Type

SAE Flare Dimensions & Weight PED

CategoryØd L H ØD B Weight

[pulg] [mm] [mm] [mm] [mm] [pulg]SYJ-42015 Flare 1/4 46 30 32 22 200 3,3SYJ-42016 Flare 3/8 57 30 32 22 240 3,3SYJ-42017 Flare 1/2 59 32 30 24 250 3,3SYJ-42018 Flare 5/8 71 37 30 24 320 3,3SYJ-42019 Flare 3/4 75 37 30 24 330 3,3

MALE / FEMALE

Every 2nd home refrigerator in Europe is equipped with a SANHUA solenoid valve

YEARLY SANHUA SUPPLIES OVER 20 MILLION SOLENOID VALVES TO THE

REFRIGERATION, HVAC AND HOME APPLIANCES INDUSTRIES WORLDWIDE

Brochure_Standard_English_02.indd 7 27/5/15 11:17

Page 8: STANDARD PRODUCT CATALOGUE

Uni-Flow Filter Driers

The filter driers of series DTG are used in refrigeration system with unidirectional flow to absorb moisture and acid in the system and to filter out the impurities.

DTG/L SERIES

SANHUA is the world’s largest producer of Micro-Channel Heat Exchangers for Stationary HVAC&R application

SANHUA DELIVERS OVER 1,300,000 MCHE CONDENSERS (CO & HP) AND

EVAPORATORS HELPING TO IMPROVE SYSTEM EFFICIENCY BY UP TO 30%

Part number

Capacity [ kW ] Moisture Absorption (gram H2O)Connection

Solder (inch)R134a

R404A/R507A

R22 R407C R410AR134a R404A/R507A R407C/R410A R22

75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F23,9°C 51,7°C 23,9°C 51,7°C 23,9°C 51,7°C 23,9°C 51,7°C

DTG-30020 7,7 6,7 8,1 8,1 8,1 4,2 3,8 5,7 3,4 3,4 3,1 3,7 3,4 1/4 DTG-30021 9,5 6,7 9,5 9,5 9,8 4,2 3,8 5,7 3,4 3,4 3,1 3,7 3,4 5/16DTG-30022 14,4 10,6 14,8 14,8 14,8 4,2 3,8 5,7 3,4 3,4 3,1 3,7 3,4 3/8 DTG-30023 24,6 17,2 25 24,6 25 4,2 3,8 5,7 3,4 3,4 3,1 3,7 3,4 1/2 DTG-30024 8,4 6 8,4 8,4 8,4 11,6 10,9 17,7 10,2 10,9 9,5 11,4 9,7 1/4 DTG-30025 10,9 7,4 10,9 10,9 11,3 11,6 10,9 17,7 10,2 10,9 9,5 11,4 9,7 5/16DTG-30026 23,9 16,9 24,3 23,9 24,6 11,6 10,9 17,7 10,2 10,9 9,5 11,4 9,7 3/8 DTG-30027 25,3 17,9 25,7 25,7 26 11,6 10,9 17,7 10,2 10,9 9,5 11,4 9,7 1/2 DTG-30028 34,8 24,6 35,5 35,2 35,9 11,6 10,9 17,7 10,2 10,9 9,5 11,4 9,7 5/8 DTG-30029 8,4 6 8,4 8,4 8,4 14,8 14,2 23,7 19,8 14,8 13 15,5 13,1 1/4 DTG-30030 11,6 8,1 12 11,6 12 14,8 14,2 23,7 19,8 14,8 13 15,5 13,1 5/16DTG-30031 25 17,6 25,3 25 25,7 14,8 14,2 23,7 19,8 14,8 13 15,5 13,1 3/8 DTG-30032 30,6 21,5 31,3 30,9 31,7 14,8 14,2 23,7 19,8 14,8 13 15,5 13,1 1/2 DTG-30033 44,7 31,7 45,7 45,4 46,1 14,8 14,2 23,7 19,8 14,8 13 15,5 13,1 5/8 DTG-30034 10,9 7,7 11,3 10,9 11,3 20,6 19,5 33,2 18,3 20,6 17,6 20,9 17,7 1/4 DTG-30035 11,6 8,1 12 11,6 12 20,6 19,5 33,2 18,3 20,6 17,6 20,9 17,7 5/16DTG-30036 25,7 17,9 26 26 26,4 20,6 19,5 33,2 18,3 20,6 17,6 20,9 17,7 3/8 DTG-30037 32,4 22,9 33,1 32,7 33,8 20,6 19,5 33,2 18,3 20,6 17,6 20,9 17,7 1/2 DTG-30038 43,3 30,6 43,6 43,6 44,3 20,6 19,5 33,2 18,3 20,6 17,6 20,9 17,7 5/8 DTG-30039 46,4 32,7 47,1 46,8 47,8 20,6 19,5 33,2 18,3 20,6 17,6 20,9 17,7 3/4 DTG-30040 47,1 33,4 48,2 47,8 48,5 20,6 19,5 33,2 18,3 20,6 17,6 20,9 17,7 7/8 DTG-30041 25,7 17,9 26 26 26,4 51,4 48,7 83,4 51,4 51,3 43,7 52,1 44,1 3/8 DTG-30042 33,1 23,2 33,8 33,4 34,1 51,4 48,7 83,4 51,4 51,3 43,7 52,1 44,1 1/2 DTG-30043 45,7 32 46,4 46,1 46,8 51,4 48,7 83,4 51,4 51,3 43,7 52,1 44,1 5/8 DTG-30044 62,6 44 63,7 63,3 64,4 51,4 48,7 83,4 51,4 51,3 43,7 52,1 44,1 3/4 DTG-30045 63 44,3 64 63,7 64,7 51,4 48,7 83,4 51,4 51,3 43,7 52,1 44,1 7/8 DTG-30046 70,7 52,1 75,3 74,6 76 51,4 48,7 83,4 51,4 51,3 43,7 52,1 44,1 1 1/8DTG-30047 35,2 24,6 35,9 35,5 36,2 63,7 59,7 103,5 55,7 63,7 58,9 70,2 59,4 1/2 DTG-30048 60,8 42,9 61,9 61,5 62,6 63,7 59,7 103,5 55,7 63,7 58,9 70,2 59,4 5/8 DTG-30049 90,4 63,7 91,8 91,4 92,8 63,7 59,7 103,5 55,7 63,7 58,9 70,2 59,4 7/8 DTG-30050 92,1 64,7 93,6 92,8 94,6 63,7 59,7 103,5 55,7 63,7 58,9 70,2 59,4 1 1/8DTG-30051 91,4 64 92,8 91,8 93,9 123,3 115,6 200,3 107,9 123,3 114 135,8 114,9 7/8 DTG-30052 95,3 67,2 97,1 96,4 98,1 123,3 115,6 200,3 107,9 123,3 114 135,8 114,9 1 1/8

Part number

Capacity [ kW ] Moisture Absorption (gram H2O)Connection

Solder (mm)R134a

R404A/R507A

R22 R407C R410AR134a R404A/R507A R407C/R410A R22

75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F23,9°C 51,7°C 23,9°C 51,7°C 23,9°C 51,7°C 23,9°C 51,7°C

DTG-30053 7,7 6,7 8,1 8,1 8,1 4,2 3,8 5,7 3,4 3,4 3,1 3,7 3,4 6 DTG-30021 9,5 6,7 9,5 9,5 9,8 4,2 3,8 5,7 3,4 3,4 3,1 3,7 3,4 8 DTG-30055 14,4 10,6 14,8 14,8 14,8 4,2 3,8 5,7 3,4 3,4 3,1 3,7 3,4 10 DTG-30056 24,6 17,2 25 24,6 25 4,2 3,8 5,7 3,4 3,4 3,1 3,7 3,4 12 DTG-30057 8,4 6 8,4 8,4 8,4 11,6 10,9 17,7 10,2 10,9 9,5 11,4 9,7 6 DTG-30025 10,9 7,4 10,9 10,9 11,3 11,6 10,9 17,7 10,2 10,9 9,5 11,4 9,7 8 DTG-30059 23,9 16,9 24,3 23,9 24,6 11,6 10,9 17,7 10,2 10,9 9,5 11,4 9,7 10 DTG-30060 25,3 17,9 25,7 25,7 26 11,6 10,9 17,7 10,2 10,9 9,5 11,4 9,7 12 DTG-30054 34,8 24,6 35,5 35,2 35,9 11,6 10,9 17,7 10,2 10,9 9,5 11,4 9,7 16 DTG-30061 8,4 6 8,4 8,4 8,4 14,8 14,2 23,7 19,8 14,8 13 15,5 13,1 6 DTG-30030 11,6 8,1 12 11,6 12 14,8 14,2 23,7 19,8 14,8 13 15,5 13,1 8 DTG-30063 25 17,6 25,3 25 25,7 14,8 14,2 23,7 19,8 14,8 13 15,5 13,1 10 DTG-30064 30,6 21,5 31,3 30,9 31,7 14,8 14,2 23,7 19,8 14,8 13 15,5 13,1 12 DTG-30062 44,7 31,7 45,7 45,4 46,1 14,8 14,2 23,7 19,8 14,8 13 15,5 13,1 16 DTG-30065 10,9 7,7 11,3 10,9 11,3 20,6 19,5 33,2 18,3 20,6 17,6 20,9 17,7 6 DTG-30035 11,6 8,1 12 11,6 12 20,6 19,5 33,2 18,3 20,6 17,6 20,9 17,7 8 DTG-30067 25,7 17,9 26 26 26,4 20,6 19,5 33,2 18,3 20,6 17,6 20,9 17,7 10 DTG-30068 32,4 22,9 33,1 32,7 33,8 20,6 19,5 33,2 18,3 20,6 17,6 20,9 17,7 12 DTG-30066 43,3 30,6 43,6 43,6 44,3 20,6 19,5 33,2 18,3 20,6 17,6 20,9 17,7 16 DTG-30040 47,1 33,4 48,2 47,8 48,5 20,6 19,5 33,2 18,3 20,6 17,6 20,9 17,7 22 DTG-30069 25,7 17,9 26 26 26,4 51,4 48,7 83,4 51,4 51,3 43,7 52,1 44,1 10 DTG-30070 33,1 23,2 33,8 33,4 34,1 51,4 48,7 83,4 51,4 51,3 43,7 52,1 44,1 12 DTG-30075 45,7 32 46,4 46,1 46,8 51,4 48,7 83,4 51,4 51,3 43,7 52,1 44,1 16 DTG-30045 63 44,3 64 63,7 64,7 51,4 48,7 83,4 51,4 51,3 43,7 52,1 44,1 22 DTG-30071 70,7 52,1 75,3 74,6 76 51,4 48,7 83,4 51,4 51,3 43,7 52,1 44,1 28 DTG-30072 35,2 24,6 35,9 35,5 36,2 63,7 59,7 103,5 55,7 63,7 58,9 70,2 59,4 12 DTG-30058 60,8 42,9 61,9 61,5 62,6 63,7 59,7 103,5 55,7 63,7 58,9 70,2 59,4 16 DTG-30049 90,4 63,7 91,8 91,4 92,8 63,7 59,7 103,5 55,7 63,7 58,9 70,2 59,4 22 DTG-30073 92,1 64,7 93,6 92,8 94,6 63,7 59,7 103,5 55,7 63,7 58,9 70,2 59,4 28 DTG-30051 91,4 64 92,8 91,8 93,9 123,3 115,6 200,3 107,9 123,3 114 135,8 114,9 22 DTG-30074 95,3 67,2 97,1 96,4 98,1 123,3 115,6 200,3 107,9 123,3 114 135,8 114,9 28

REFRIGERANTR22, R134a, R404A, R407C, R410A, R507A

PS 48,3 bar

FILTRATION 20 µm

LARGE TEMPERATURE SERVICE RANGE -30°C to +120°C

* Also Available composed of 80% 3A dessicant and 20% active alumina visit sanhuaeurope.com

SELECTION FORMULAS Filter Drier for liquid line are manufactured in compliance with ARI Standard 710. Maximum flow rate of liquid refrigerant at a differential pressure of 0,07bar (1psi) is indicated by kW (ton) which is based on the temperature of liquid refrigerant 30°C (86°F) and the following mass flow:

• 0,40 kg/min/kW (3.1 lb/min/ton) R134a

• 0,53 kg/min/kW (4.1 lb/min/ton) R404A, R507A

• 0,39 kg/min/kW (3.0 lb/min/ton) R22, R407C

• PS: 4,83 MPa• 0,36 kg/min/kW (2.8 lb/min/

ton) R410A

Note: Data on water absorption is based on the following EPD (method: ASHRAE Standard 63.1):• 60ppm R22• 15ppm R12• 30ppm R502• 50ppm R134a, R404A, R507A,

R410A, R407C

Note: The above data is based on clean system at ideal conditions;with impurities accumulated in the filter, the flow may decrease.

Please visit our website www.sanhuaeurope.com and link to the technical information section to find the complete information of every product.

SOLID FILTER CORE*

RoHS

UL CSA PED

Part number

Capacity [ kW ] Moisture Absorption (gram H2O)Connection SAE Flare

(inch)R134aR404A/R507A

R22 R407C R410AR134a R404A/R507A R407C/R410A R22

75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F23,9°C 51,7°C 23,9°C 51,7°C 23,9°C 51,7°C 23,9°C 51,7°C

DTG-30001 7,7 6,7 8,1 8,1 8,1 4,2 3,8 5,7 3,4 3,4 3,1 3,7 3,4 1/4 DTG-30002 14,4 10,6 14,8 14,8 14,8 4,2 3,8 5,7 3,4 3,4 3,1 3,7 3,4 3/8 DTG-30153 24,6 17,2 25 24,6 25 4,2 3,8 5,7 3,4 3,4 3,1 3,7 3,4 1/2 DTG-30003 8,4 6 8,4 8,4 8,4 11,6 10,9 17,7 10,2 10,9 9,5 11,4 9,7 1/4 DTG-30004 23,9 16,9 24,3 23,9 24,6 11,6 10,9 17,7 10,2 10,9 9,5 11,4 9,7 3/8 DTG-30005 8,4 6 8,4 8,4 8,4 14,8 14,2 23,7 19,8 14,8 13 15,5 13,1 1/4 DTG-30006 25 17,6 25,3 25 25,7 14,8 14,2 23,7 19,8 14,8 13 15,5 13,1 3/8 DTG-30007 30,6 21,5 31,3 30,9 31,7 14,8 14,2 23,7 19,8 14,8 13 15,5 13,1 1/2 DTG-30008 10,9 7,7 11,3 10,9 11,3 20,6 19,5 33,2 18,3 20,6 17,6 20,9 17,7 1/4 DTG-30009 25,7 17,9 26 26 26,4 20,6 19,5 33,2 18,3 20,6 17,6 20,9 17,7 3/8 DTG-30010 32,4 22,9 33,1 32,7 33,8 20,6 19,5 33,2 18,3 20,6 17,6 20,9 17,7 1/2 DTG-30011 43,3 30,6 43,6 43,6 44,3 20,6 19,5 33,2 18,3 20,6 17,6 20,9 17,7 5/8 DTG-30012 46,4 32,7 47,1 46,8 47,8 20,6 19,5 33,2 18,3 20,6 17,6 20,9 17,7 3/4 DTG-30013 25,7 17,9 26 26 26,4 51,4 48,7 83,4 51,4 51,3 43,7 52,1 44,1 3/8 DTG-30014 33,1 23,2 33,8 33,4 34,1 51,4 48,7 83,4 51,4 51,3 43,7 52,1 44,1 1/2 DTG-30015 45,7 32 46,4 46,1 46,8 51,4 48,7 83,4 51,4 51,3 43,7 52,1 44,1 5/8 DTG-30016 62,6 44 63,7 63,3 64,4 51,4 48,7 83,4 51,4 51,3 43,7 52,1 44,1 3/4 DTG-30017 63 44,3 64 63,7 64,7 51,4 48,7 83,4 51,4 51,3 43,7 52,1 44,1 7/8 DTG-30018 35,2 24,6 35,9 35,5 36,2 63,7 59,7 103,5 55,7 63,7 58,9 70,2 59,4 1/2 DTG-30019 60,8 42,9 61,9 61,5 62,6 63,7 59,7 103,5 55,7 63,7 58,9 70,2 59,4 5/8

DECLARATION OF CONFORMITY:

Pressure Equipment Directive 97/23/EC

Brochure_Standard_English_02.indd 8 27/5/15 11:17

Page 9: STANDARD PRODUCT CATALOGUE

Bi-Flow Filter Drier

The filter driers of series STG are used in refrigeration system with bi-directional flow to absorb moisture and acid in the system and to filter out the impurities.

SELECTION FORMULAS Filter Drier for liquid line are manufactured in compliance withARI Standard 710. Maximum flow rate of liquid refrigerant at adifferential pressure of 0,07bar (1psi) is indicated by kW (ton)which is based on the temperature of liquid refrigerant 30°C (86°F) and the following mass flow:

• 0,40 kg/min/kW (3.1 lb/min/ton) R134a

• 0,53 kg/min/kW (4.1 lb/min/ton) R404A, R507A

• 0,39 kg/min/kW (3.0 lb/min/ton) R22, R407C

• PS: 4,83 MPa• 0,36 kg/min/kW (2.8 lb/min/

ton) R410A

Note: Data on water absorption is based on the following EPD(method: ASHRAE Standard 63.1):• 60ppm R22• 15ppm R12• 30ppm R502• 50ppm R134a, R404A, R507A,

R410A, R407C

SOLID FILTER CORE*STG/L SERIES

REFRIGERANTR22, R134a, R404A, R407C, R410A, R507A

PS 48,3 bar

FILTRATION 20 µm

LARGE TEMPERATURE SERVICE RANGE -30°C to +120°C

Part number

Capacity [ kW ] 1) Moisture Absorption (gram H2O)Connection SAE Flare

(inch)R134aR404A/R507A

R22 R407C2) R410AR134a R404A/R507AR407C2)/R410A R22

75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F23,9°C 51,7°C 23,9°C 51,7°C 23,9°C 51,7°C 23,9°C 51,7°C

STG-31001 7,4 5,3 7,7 7,7 7,7 4,3 4 4,1 3,8 3,7 3,4 4,1 3,7 1/4 STG-31002 16,5 11,6 16,9 16,5 16,9 4,3 4 4,1 3,8 3,7 3,4 4,1 3,7 3/8 STG-31003 25 17,6 25,3 25 25,3 4,3 4 4,1 3,8 3,7 3,4 4,1 3,7 1/2 STG-31004 8,8 6 8,8 8,8 8,8 9,8 9 9,2 8,6 8,5 7,8 9,2 8,5 1/4 STG-31005 17,2 12 17,6 17,2 17,6 9,8 9 9,2 8,6 8,5 7,8 9,2 8,5 3/8 STG-31006 25,7 17,9 26,4 26 26,4 9,8 9 9,2 8,6 8,5 7,8 9,2 8,5 1/2 STG-31007 19,7 13,7 20 19,7 20 17,6 16,3 16,6 15,5 15,2 14 16,6 14,2 3/8 STG-31008 30,2 21,5 30,9 30,6 30,9 17,6 16,3 16,6 15,5 15,2 14 16,6 14,2 1/2 STG-31009 34,1 23,9 34,8 34,5 35,2 17,6 16,3 16,6 15,5 15,2 14 16,6 14,2 5/8 STG-31010 25 17,6 25,3 25 25,7 41,3 38,4 38,9 36,5 35,9 32,9 39,1 33,1 3/8 STG-31011 30,9 21,8 31,7 31,7 32 41,3 38,4 38,9 36,5 35,9 32,9 39,1 33,1 1/2 STG-31012 35,5 25 36,2 35,9 36,6 41,3 38,4 38,9 36,5 35,9 32,9 39,1 33,1 5/8 STG-31013 39,6 28,1 40,1 39,7 40,4 41,3 38,4 38,9 36,5 35,9 32,9 39,1 33,1 3/4

Part number

Capacity [ kW ] 1) Moisture Absorption (gram H2O)Connection

solder (inch)R134a

R404A/R507A

R22 R407C2) R410AR134a R404A/R507AR407C2)/R410A R22

75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F23,9°C 51,7°C 23,9°C 51,7°C 23,9°C 51,7°C 23,9°C 51,7°C

STG-31014 7,4 5,3 7,7 7,7 7,7 4,3 4 4,1 3,8 3,7 3,4 4,1 3,7 1/4 STG-31015 16,5 11,6 16,9 16,5 16,9 4,3 4 4,1 3,8 3,7 3,4 4,1 3,7 3/8 STG-31016 25 17,6 25,3 25 25,3 4,3 4 4,1 3,8 3,7 3,4 4,1 3,7 1/2 STG-31017 8,8 6 8,8 8,8 8,8 9,8 9 9,2 8,6 8,5 7,8 9,2 8,5 1/4 STG-31018 15,8 10,9 16,2 15,8 16,2 9,8 9 9,2 8,6 8,5 7,8 9,2 8,5 5/16 STG-31019 17,2 12 17,6 17,2 17,6 9,8 9 9,2 8,6 8,5 7,8 9,2 8,5 3/8 STG-31020 25,7 17,9 26,4 26 26,4 9,8 9 9,2 8,6 8,5 7,8 9,2 8,5 1/2 STG-31021 19,7 13,7 20 19,7 20 17,6 16,3 16,6 15,5 15,2 14 16,6 14,2 3/8 STG-31022 30,2 21,5 30,9 30,6 30,9 17,6 16,3 16,6 15,5 15,2 14 16,6 14,2 1/2 STG-31023 34,1 23,9 34,8 34,5 35,2 17,6 16,3 16,6 15,5 15,2 14 16,6 14,2 5/8 STG-31024 42,2 29,9 42,9 42,6 43,3 17,6 16,3 16,6 15,5 15,2 14 16,6 14,2 7/8 STG-31025 25 17,6 25,3 25 25,7 41,3 38,4 38,9 36,5 35,9 32,9 39,1 33,1 3/8 STG-31026 30,9 21,8 31,7 31,7 32 41,3 38,4 38,9 36,5 35,9 32,9 39,1 33,1 1/2 STG-31027 35,5 25 36,2 35,9 36,6 41,3 38,4 38,9 36,5 35,9 32,9 39,1 33,1 5/8 STG-31028 39,6 28,1 40,1 39,7 40,4 41,3 38,4 38,9 36,5 35,9 32,9 39,1 33,1 3/4 STG-31029 46,4 32,4 47,1 46,8 47,5 41,3 38,4 38,9 36,5 35,9 32,9 39,1 33,1 7/8 STG-31030 54,2 38 55,2 54,5 55,6 41,3 38,4 38,9 36,5 35,9 32,9 39,1 33,1 1 1/2

Part number

Capacity [ kW ] 1) Moisture Absorption (gram H2O)Connection

Solder (mm)R134a

R404A/R507A

R22 R407C2) R410AR134a R404A/R507AR407C2)/R410A R22

75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F23,9°C 51,7°C 23,9°C 51,7°C 23,9°C 51,7°C 23,9°C 51,7°C

STG-31031 7,4 5,3 7,7 7,7 7,7 4,3 4 4,1 3,8 3,7 3,4 4,1 3,7 6 STG-31032 16,5 11,6 16,9 16,5 16,9 4,3 4 4,1 3,8 3,7 3,4 4,1 3,7 10 STG-31033 25 17,6 25,3 25 25,3 4,3 4 4,1 3,8 3,7 3,4 4,1 3,7 12 STG-31034 8,8 6 8,8 8,8 8,8 9,8 9 9,2 8,6 8,5 7,8 9,2 8,5 6 STG-31018 15,8 10,9 16,2 15,8 16,2 9,8 9 9,2 8,6 8,5 7,8 9,2 8,5 8 STG-31035 17,2 12 17,6 17,2 17,6 9,8 9 9,2 8,6 8,5 7,8 9,2 8,5 10 STG-31036 25,7 17,9 26,4 26 26,4 9,8 9 9,2 8,6 8,5 7,8 9,2 8,5 12 STG-31037 19,7 13,7 20 19,7 20 17,6 16,3 16,6 15,5 15,2 14 16,6 14,2 10 STG-31038 30,2 21,5 30,9 30,6 30,9 17,6 16,3 16,6 15,5 15,2 14 16,6 14,2 12 STG-31087 34,1 23,9 34,8 34,5 35,2 17,6 16,3 16,6 15,5 15,2 14 16,6 14,2 16 STG-31024 42,2 29,9 42,9 42,6 43,3 17,6 16,3 16,6 15,5 15,2 14 16,6 14,2 22 STG-31039 25 17,6 25,3 25 25,7 41,3 38,4 38,9 36,5 35,9 32,9 39,1 33,1 10 STG-31040 30,9 21,8 31,7 31,7 32 41,3 38,4 38,9 36,5 35,9 32,9 39,1 33,1 12 STG-31088 35,5 25 36,2 35,9 36,6 41,3 38,4 38,9 36,5 35,9 32,9 39,1 33,1 16 STG-31029 46,4 32,4 47,1 46,8 47,5 41,3 38,4 38,9 36,5 35,9 32,9 39,1 33,1 22 STG-31043 54,2 38 55,2 54,5 55,6 41,3 38,4 38,9 36,5 35,9 32,9 39,1 33,1 28

Cooper Filter Drier

REFRIGERANTR134a, R404A, R407C, R410A, R507A, R600a

PS42 bar

LARGE TEMPERATURE SERVICE RANGE -30°C to +80°C

BGQ SERIESThe copper filter driers of series BGQ are used in refrigeration system with unidirectional flow to absorb moisture and acid in the system and to filter out the impurities.

Part number Inlet connection (mm) / type

Outlet connection (mm) / type

Molec sieve Type

Refrigerant

BGQ-28001 6,35 ODF 6,35 ODF XH-11R134a, R600a

R404A, R407C, R410A

BGQ-28002 6,5 ODF 6,35 ODM XH-11 R134a, R600a

R404A, R407C, R410A

BGQ-28003 9,52 ODF 9,52 ODM XH-9 R134a, R600a

* Also Available composed of 80% 3A dessicant and 20% active alumina visit sanhuaeurope.com

Please visit our website www.sanhuaeurope.com and link to the technical information section to find the complete information of every product.

DECLARATION OF CONFORMITY:

Pressure Equipment Directive 97/23/EC

DECLARATION OF CONFORMITY:

Pressure Equipment Directive 97/23/EC

RoHS

RoHS PED

Note 1): The above data is based on clean system at ideal conditions;with impurities accumulated in the filter, the flow may decrease.

Brochure_Standard_English_02.indd 9 27/5/15 11:17

Page 10: STANDARD PRODUCT CATALOGUE

Note: Conditions could change without previous notice due to components updating or typing mistakes. Sanhua declines any responsibility for a wrong product choice based on this table. Please make sure all your requirements are covered in our suggestion.Please visit our website www.sanhuaeurope.com and link to the technical information section to find the complete information of every product.

Filter Driers with (Replaceable Core)

HTG SERIE

The filter driers with replaceable core (HTG series) are used in liquid line and suction line of refrigerating, freezing and air conditioning system. The filter housing allows to choose different kinds of cores. It’s sealed by bottom cover for an easy removal and replacement of core from the bottom. The core holder requires minimum free space to remove the core for replacement.

SELECTION FORMULAS Filter driers for liquid line are manufactured in compliance with ARI Standard 710. Maximum flow rate of liquid refrigerant at a differential pressure of 0,07bar (1psi) is indicated by kW (ton) which is based on the temperature of liquid refrigerant 30°C (86°F), the evaporating temperature of -15°C (5°F) and the following mass flow:

• 0,40 kg/min/kW (3.1 lb/min/ton) R134a • 0,53 kg/min/kW (4.1 lb/min/ton) R404A, R507A• 0,39 kg/min/kW (3.0 lb/min/ton) R22, R407C • 0,36 kg/min/kW (2.8 lb/min/ton) R410A

Note: Data on water absorption is based on the following EPD (method: AS HRAE Standard 63.1):

• 60ppm R22 • 50ppm R134a • 50ppm R404A • 50ppm R407C • 50ppm R410A • 50ppm R507A

REFRIGERANTR22, R134a, R404A, R407C, R410A, R507A

PS 45 bar

FILTRATION 20 µm

LARGE TEMPERATURE SERVICE RANGE-40°C / +120°C

*Also Available composed of 80% 3A dessicant and 20% active alumina www.sanhuaeurope.com

RoHS

Note 1): The above data is based on clean system at ideal conditions; with impurities accumulated in the filter, the flow may decrease.

DECLARATION OF CONFORMITY:

Pressure Equipment Directive 97/23/EC

Part number

Capacity [kW] 1 Moisture Absorption [gram H2O] Moisture Absorption [gram H

2O]

R134a R404A

R22 R407C2) R410AR134a

R404A R407C2)

R22 R134aR404A R407C2)

R22R507A R410A R507A R410A

R507A75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F

23,9°C 51,7°C 23,9°C 51,7°C 23,9°C 51,7°C 23,9°C 51,7°C 23,9°C 51,7°C 23,9°C 51,7°C 23,9°C 51,7°C 23,9°C 51,7°CHTG-29001 65,5 45,9 67,6 67,6 67,6 67,4 58,1 72,6 59,6 57,0 51,8 62,2 57,0 58,0 50,0 61,7 50,7 47,9 43,5 52,9 48,5HTG-29002 104,7 73,5 108,2 108,2 108,2 67,4 58,1 72,6 59,6 57,0 51,8 62,2 57,0 58,0 50,0 61,7 50,7 47,9 43,5 52,9 48,5HTG-29003 150,5 105,7 155,4 155,4 155,4 67,4 58,1 72,6 59,6 57,0 51,8 62,2 57,0 58,0 50,0 61,7 50,7 47,9 43,5 52,9 48,5HTG-29004 150,5 105,7 155,4 155,4 155,4 67,4 58,1 72,6 59,6 57,0 51,8 62,2 57,0 58,0 50,0 61,7 50,7 47,9 43,5 52,9 48,5HTG-29005 202,7 142,5 209,3 209,3 209,3 67,4 58,1 72,6 59,6 57,0 51,8 62,2 57,0 58,0 50,0 61,7 50,7 47,9 43,5 52,9 48,5HTG-29006 248,9 174,7 256,6 256,6 256,6 67,4 58,1 72,6 59,6 57,0 51,8 62,2 57,0 58,0 50,0 61,7 50,7 47,9 43,5 52,9 48,5HTG-29007 59,9 174,7 256,6 256,6 256,6 67,4 58,1 72,6 59,6 57,0 51,8 62,2 57,0 58,0 50,0 61,7 50,7 47,9 43,5 52,9 48,5HTG-29008 353,5 248,2 364,7 364,7 364,7 67,4 58,1 72,6 59,6 57,0 51,8 62,2 57,0 58,0 50,0 61,7 50,7 47,9 43,5 52,9 48,5HTG-29009 392,7 276,2 405,7 405,7 405,7 67,4 58,1 72,6 59,6 57,0 51,8 62,2 57,0 58,0 50,0 61,7 50,7 47,9 43,5 52,9 48,5HTG-29010 65,5 45,9 67,6 67,6 67,6 134,8 116,1 145,2 119,2 114,0 103,7 124,4 114,0 115,9 99,8 123,4 101,3 95,8 87,1 105,7 96,9HTG-29011 104,7 73,5 108,2 108,2 108,2 134,8 116,1 145,2 119,2 114,0 103,7 124,4 114,0 115,9 99,8 123,4 101,3 95,8 87,1 105,7 96,9HTG-29012 150,5 105,7 155,4 155,4 155,4 134,8 116,1 145,2 119,2 114,0 103,7 124,4 114,0 115,9 99,8 123,4 101,3 95,8 87,1 105,7 96,9HTG-29013 150,5 105,7 155,4 155,4 155,4 134,8 116,1 145,2 119,2 114,0 103,7 124,4 114,0 115,9 99,8 123,4 101,3 95,8 87,1 105,7 96,9HTG-29014 202,7 142,5 209,3 209,3 209,3 134,8 116,1 145,2 119,2 114,0 103,7 124,4 114,0 115,9 99,8 123,4 101,3 95,8 87,1 105,7 96,9HTG-29015 248,9 174,7 256,6 256,6 256,6 134,8 116,1 145,2 119,2 114,0 103,7 124,4 114,0 115,9 99,8 123,4 101,3 95,8 87,1 105,7 96,9HTG-29016 248,9 174,7 256,6 256,6 256,6 134,8 116,1 145,2 119,2 114,0 103,7 124,4 114,0 115,9 99,8 123,4 101,3 95,8 87,1 105,7 96,9HTG-29017 353,5 248,2 364,7 364,7 364,7 134,8 116,1 145,2 119,2 114,0 103,7 124,4 114,0 115,9 99,8 123,4 101,3 95,8 87,1 105,7 96,9HTG-29018 392,7 276,2 405,7 405,7 405,7 134,8 116,1 145,2 119,2 114,0 103,7 124,4 114,0 115,9 99,8 123,4 101,3 95,8 87,1 105,7 96,9HTG-29019 65,5 45,9 67,6 67,6 67,6 202,2 174,3 217,8 178,8 171,0 155,4 186,6 171,0 173,9 149,9 185,1 152,0 143,6 130,5 158,6 145,4HTG-29020 104,7 73,5 108,2 108,2 108,2 202,2 174,3 217,8 178,8 171,0 155,4 186,6 171,0 173,9 149,9 185,1 152,0 143,6 130,5 158,6 145,4HTG-29021 150,5 105,7 155,4 155,4 155,4 202,2 174,3 217,8 178,8 171,0 155,4 186,6 171,0 173,9 149,9 185,1 152,0 143,6 130,5 158,6 145,4HTG-29022 150,5 105,7 155,4 155,4 155,4 202,2 174,3 217,8 178,8 171,0 155,4 186,6 171,0 173,9 149,9 185,1 152,0 143,6 130,5 158,6 145,4HTG-29023 202,7 142,5 209,3 209,3 209,3 202,2 174,3 217,8 178,8 171,0 155,4 186,6 171,0 173,9 149,9 185,1 152,0 143,6 130,5 158,6 145,4HTG-29024 248,9 174,7 256,6 256,6 256,6 202,2 174,3 217,8 178,8 171,0 155,4 186,6 171,0 173,9 149,9 185,1 152,0 143,6 130,5 158,6 145,4HTG-29025 248,9 174,7 256,6 256,6 256,6 202,2 174,3 217,8 178,8 171,0 155,4 186,6 171,0 173,9 149,9 185,1 152,0 143,6 130,5 158,6 145,4HTG-29026 353,5 248,2 364,7 364,7 364,7 202,2 174,3 217,8 178,8 171,0 155,4 186,6 171,0 173,9 149,9 185,1 152,0 143,6 130,5 158,6 145,4HTG-29027 392,7 276,2 405,7 405,7 405,7 202,2 174,3 217,8 178,8 171,0 155,4 186,6 171,0 173,9 149,9 185,1 152,0 143,6 130,5 158,6 145,4HTG-29028 65,5 45,9 67,6 67,6 67,6 269,6 232,4 290,4 238,4 228,0 207,2 248,8 228,0 231,9 199,9 246,8 202,6 191,5 174,0 211,5 193,8HTG-29029 104,7 73,5 108,2 108,2 108,2 269,6 232,4 290,4 238,4 228,0 207,2 248,8 228,0 231,9 199,9 246,8 202,6 191,5 174,0 211,5 193,8HTG-29030 150,5 105,7 155,4 155,4 155,4 269,6 232,4 290,4 238,4 228,0 207,2 248,8 228,0 231,9 199,9 246,8 202,6 191,5 174,0 211,5 193,8HTG-29031 150,5 105,7 155,4 155,4 155,4 269,6 232,4 290,4 238,4 228,0 207,2 248,8 228,0 231,9 199,9 246,8 202,6 191,5 174,0 211,5 193,8HTG-29032 202,7 142,5 209,3 209,3 209,3 269,6 232,4 290,4 238,4 228,0 207,2 248,8 228,0 231,9 199,9 246,8 202,6 191,5 174,0 211,5 193,8HTG-29033 248,9 174,7 256,6 256,6 256,6 269,6 232,4 290,4 238,4 228,0 207,2 248,8 228,0 231,9 199,9 246,8 202,6 191,5 174,0 211,5 193,8HTG-29034 248,9 174,7 256,6 256,6 256,6 269,6 232,4 290,4 238,4 228,0 207,2 248,8 228,0 231,9 199,9 246,8 202,6 191,5 174,0 211,5 193,8HTG-29035 353,5 248,2 364,7 364,7 364,7 269,6 232,4 290,4 238,4 228,0 207,2 248,8 228,0 231,9 199,9 246,8 202,6 191,5 174,0 211,5 193,8HTG-29036 392,7 276,2 405,7 405,7 405,7 269,6 232,4 290,4 238,4 228,0 207,2 248,8 228,0 231,9 199,9 246,8 202,6 191,5 174,0 211,5 193,8

FILTER WITH REPLACEABLE CORE SH48-A00 SH48A-A80

Suction line Filter-Driers guarantees an acid removal and a drying capacity described in table 7:

Drying capacity is expressed during drying in:

R22: EPD = 10 ppm W, corresponding dew point temperature is -50°C

R134a: EPD = 50 ppm W, corresponding dew point temperature is -37°C

R404A: EPD = 10 ppm W, corresponding dew point temperature is -40°C

R407C: EPD = 10 ppm W, corresponding dew point temperature is -40°C

Drying capacity: SH48-A301)

Filter Type HTG-A48 HTG-A96 HTG-B44 HTG-B92

Number of cores 1 2 3 4

Acid Adsorption capacity (g)3) 28,0 56,0 84,0 112,0

Refrigerant Evaporating Temp. (°C)4) Moisture Absorption [gram H2O]

R22/ R407C2)

-40,0 26,0 52,0 78,0 104,0-20,0 18,0 36,3 54,0 72,0

4,4 11,0 22,0 32,0 43,0

R134a-30,0 43,0 86,0 129,0 172,0-20,0 36,0 72,0 108,0 144,0

4,4 25,0 50,0 75,0 100,0

R404A / R507-40,0 45,0 90,0 135,0 180,0-20,0 28,0 56,0 84,0 112,0

4,4 18,0 36,0 54,0 72,0

R410A-40,0 40,0 80,0 120,0 160,0-20,0 33,0 66,0 99,0 132,0

4,4 24,0 48,0 72,0 96,0

Note: 1. The data reported in the Table 2, 3, 6 and 7 are based on filter driers in a clean system at ideal conditions; with impurities accumulated in the filter, the capacity may decrease. 2. R407C data based on dew point conditions 3. Adsorption capacity of oleic acid at 0.05 TAN (Total Acid Number) 4. Standard Evaporating Temperature defined by ANSI.AHRI Standard 731 (SI)-2013 5. Standard Evaporating Temperature defined by ANSI.AHRI Standard 730 (I-P)-2013

Brochure_Standard_English_02.indd 10 27/5/15 11:17

Page 11: STANDARD PRODUCT CATALOGUE

SANHUA INTERNATIONAL [email protected]

Technicalinformation sanhuaeurope.com

Note: Conditions could change without previous notice due to components updating or typing mistakes. Sanhua declines any responsibility for a wrong product choice based on this table. Please make sure all your requirements are covered in our suggestion.

CA-COM-EN-R0515

BEST SUPPLIER AWARDS

Certificate of registration ISO 14001:2004

Certificate of registration ISO 9001:2008

NR. 1907/2006 CONFORMITY DECLARATION

REACH

Brochure_Standard_English_02.indd 11 27/5/15 11:17

Page 12: STANDARD PRODUCT CATALOGUE

OFFICIAL DEALER:

sanhuaeurope.com

CHILLING IDEAS WORLDWIDE

Brochure_Standard_English_02.indd 12 27/5/15 11:17