standard type 2062-185 product data stack parker 2'-8 2062 · conformity product data stack...
TRANSCRIPT
CONFORMITY
Product DataStack Parker
2062
see
tab
le
15°
12°
13°
15°
12°
13°
see
tab
le* = standard type
*
A1Free space forroller shutter
A3
A2 Hei
ght (
H)
2% 2%
Drainage channelwith sump
Free space
Free space
2%
Cu
ttin
g t
hro
ug
h
(DH
) Hei
ght (
H)
Clea
r he
ight
Del
imit
atio
n
2%
Drainage channelwith sump
Standard Type 2062-185
Hei
ght (
H)
Hei
ght (
H)
5'-3" 1'-6"
6'-1
0"
1'-8"17'-1" (for vehicle up to 16’4’’ long)
6'-1
"
6'-3
"
3'-3
"1'
-8"
Compact Type 2062-170 Exclusive Type 2062-195
1'-8"
7'-0
"2'
-8"
2'-8
"
»17'-9" (for vehicle up to 17’ long)«
6'-5
"5'-7
"
5'-9
"
6'-7
"
4'-11" 4'-11"10'-8"
11'-2" 4'-11" 5'-5"
11'-6" 4'-11" 5'-9"
5'-3"
5'-3"
16'-5" <17'-1">3'-1"
3'-3"16'-5" <17'-1">
4'-1"
4'-1"
3'-3
"3'
-5"
2'-2" 4'-9"
4'-7
"3'
-1"
1'
3'-0
"
Phone 925-284-2092Fax 925-284-3365
INTERNET: www.parklift.com
2062-1702062-185*
10'-8" 5'-2"
11'-2" 5'-7"2062-195 11'-6" 5'-11"
Dimensions:All space requirements are minimum nished dimensions. Tolerances for space requirements are in feet & inches.EB (single platform) = 2 vehiclesDB (double platform) = 4 vehicles
1
3
5
4
TYPE H DH**
= standard type ** = without car
Suitable for:Standard passenger car and station wagon.Height and length according to contour.
TYPE H Upper Lower2062-1702062-185*2062-195
6'-3"
1
2
2
WHEEL LOAD
3
4
5 4" wide yellow stripe recommended at edge of machine (BUYER)
WIDTH WEIGHT
Standard passenger car
Standard station wagon
Standard passenger cars are vehicles without any sports options such as
KLAUS MULTIPARKING INC.3652A CHESTNUT STREETLAFAYETTE CA. 94549
For dividing walls: cutting through 4"x 4" (for pipes).
Dimensions A1, A2 and A3 must becoordinated with the door supplier.
If the total height is greater, the max. vehicle height for the upper parking space increases accordingly.
For the greatest possible ease-of-use, we recommend platform widths of 8'-3" to 8'-10" (EB) or 16'-5"(DB).
2
2
3
car parking system
For cars up to a length of 17'-1" please note:Pit length 17'-9" (with towbar 18'-1" ), max. authorized loading 5,500lbs (wheel loadmax. 1,375lbs ), usuable platform width 8'-3" – 8'-10" . Only Stack Parker 2062-170/185/195 EBis possible. Special model!
CAR HEIGHT
MAX. 4400/5500 LBSMAX. 1100/1375 LBS
spoilers, low-profile tires etc.
Garage with door in front of the Notes
Attention:
End parking spaces are generally more difficult to drive into. Therefore we recommended for end parking spaces our wider platforms.Parking on standard width platforms with larger vehicles may make getting into and out of the vehicle difficult. This depends on type of vehicle, approach and above all on the individual driver’s skill.
Please note:
Widths for garage with door in front of car parking system
Width for basement garage
Dividing walls
Columns in pit
Columns outside pit
Single platform (EB) Double platform (DB)
B1
EB
B1
DB
B1
EB DB
Carriageway in accordancewith local regulations
Single Platform (EB) Double Platform (DB) Single and Double Platform (EB + DB) – Example
usable platform width B1 B1 B1usable platform width usable platform width
EB EB
B
max
.m
ax.
DB DB
B
max
.m
ax.
EB EBDB DB
B
max
.m
ax.
Carriageway in accordancewith local regulations
Single Platform (EB) Double Platform (DB) Single and Double Platform (EB + DB) – Example
B2 B3 B2 B3B2 B3usable platform width usable platform width usable platform width
B4
EB EB
B5 4
DB DB
B5 4
DB DB
B5
EB EB
Carriageway in accordancewith local regulations
Single Platform (EB) Double Platform (DB) Single and Double Platform (EB + DB)
*
B4 B5 B5B4
270 + 500
*
B4 B5usable platform width usable platform width usable platform width
DF
EB
A3
L LDF
DB
L LDF
EB
L SDF
S
EB
DF
DB
L SDF
S
DB
1
Carriageway in accordancewith local regulations
L S usable platform width L Sdoor entrance width DF
A3 = seat-engagingsurface (dimensionsrequire coordinationwith door supplier.)
Allround doordimensions requirecoordination betweendoor supplier andlocal agency ofKlaus Multiparking.
usable platform width door entrance width DF
15'-5" 16'-3" 15'-11"
7'-11" + 15'-5" 25'-3"
*
***
7'-7" + 15'-1" 24'-3" 23'-11"7'-11" + 15'-5" 24'-11" 24'-7"
8'-10" + 16'-5" 26'-11" 26'-7"8'-6" + 16'-1" 26'-3" 25'-11"
7'-11" + 15'-5" 25'-1" 15'-9" 16'-7" 16'-3" 8'-3" + 15'-9" 25'-9" 25'-5"
24'-9"
16'-1" 17'-1"16'-5" 17'-5" 8'-10" + 16'-5" 27'-3"
15'-1" 15'-11" 15'-7"
*
* *
4'-7
"
1'
- 0"
min. 8" min. 8"
4'-7
"
1'
-0"
B2 3 B2 3 B2 3 min. 8"
4'-7
"
1'
-0"
min. 8" B min. 8" B min. 8"
5" 10"5" 10" 15'-5" 15'-7" 5" 10"
16'-1" 16'-5" 5" 10"16'-5" 16'-5" 6" 1'
7'-7"(230cm) 8'-6" 15'-1" 16'-1" 7'-7" + 15'-1" 24'-7"7'-11"(240cm) 8'-10" 15'-5" 16'-5" 8'-3" (250cm) 9'-2" 15'-9" 16'-9" 8'-3" + 15'-9" 25'-11" 8'-6" (260cm) 9'-6" 8'-6" + 16'-1" 26'-7"8'-10"(270cm) 9'-10"
7'-11"(240cm) 8'-8" 8'-6"8'-3" (250cm) 9'-0" 8'-10"
8'-6" (260cm) 9'-4" 9'-2" 16'-1" 16'-11" 16'-7" 8'-6" + 16'-1" 26'-5" 26'-1" 8'-10"(270cm) 9'-8" 9'-6" 16'-5" 17'-3" 16'-11" 8'-10"+ 16'-5" 27'-1" 26'-9"
7'-7" (230cm) 8'-3" 7'-11" 15'-1" 15'-9" 15'-5" 7'-11"(240cm) 8'-6" 8'-2" 15'-5" 16'-1" 15'-9"
8'-10" 8'-6" 15'-9" 16'-5" 16'-1" 8 '-3" + 15'-9" 25'-7" 25'-3"8'-3" (250cm) 9'-2" 8'-10" 16'-1" 16'-9" 16'-5"8'-6"(260cm)
8'-10"(270cm) 9'-6" 9'-2" 16'-5" 17'-1" 16'-9"
7'-7"(230cm) 7'-9"7'-11"(240cm) 8'-3"
15'-1" 15'-1" 6" 1'
* = standard width (parking space width 7'-7") = no standard width for doors!1
8'-3" (250cm) 8'-3" 6" 1' 15'-9" 15'-7" 7" 1'-2" 8'-6" (260cm) 8'-6" 6" 1' 8'-10"(270cm) 8'-10" 6" 1'
7'-7"(230cm) 8'-4" 8'-3" 7'-7" + 15'-1" 24'-5" 24'-1"
Approach
4 %
14 %
Installation data
Free space for longitudinal and vertical ducts (e.g. ventilation)
B1 0 B1 0 B1 B1 0 0
B2B3B2
EB EB DB DB
Approach level
Free space for vertical pipelines,ventilation branch canals
8" 8"
(8'-8") (8'-7") (16'-2") (16'-3")
1'
(8'-4")
max
. 4'-7
"
≥8" ≥8"(24'-1") (15'-11")
Seismic Bracing
Approach Level
Free space for vertical pipes forelectrical, water & air vents
Free space for horizontal ducting
Free space only applicable if vehicleis parked forwards = FRONT FIRSTand driver•s door on the left side.
( ) = Dimensions in bracketsillustrate an example for usableplatform width 7'-7"/15'-1".
Example for ventilation branchcanal and/or vertical pipelines.
The illustrated maximum approach angles must not be exceeded. Exceeding these slopeswill cause maneuvering problems and will restrict car sizes on the parking system.
1'-2" 1'-2" 1'-2" 1'-2" 4"4" 4" 4"
_
B1, B2, B3 = (see table on page 2)
_
B B B B 1 1 1 1
B B B2 3 2
RANGE OF APPLICATIONThis parking system is suitable for self parking by owners, renters, regularemployees or anyone that can be trained on the system. The public may not park onthis system without a valet.ENVIRONMENTAL CONDITIONS
system must be installed indoors. If lifting or lowering times are specified, they referto an environmental temperature of 72° F and with system set up directly next to thehydraulic unit. At lower temperatures or with longer hydraulic lines, these timesincrease.
SPACE NUMBERING
The hydraulic power unit is normally installed against the back wall on a metalbracket with rubber sound insulation. It consists of an electric motor, hydraulicmotor and hydraulic oil reservoir in one unit. The hydraulic oil is biodegradable and
CORROSION PROTECTIONThe platforms are galvanized and the steel framing members are powder coated.The platforms should be cleaned annually to maximize their life.
SERVICETo maintain safe and reliable operation of the machine, it must be serviced twice peryear.
To machine has a complete one year parts and labor warranty. Klaus providesextended warranties.
machine are provided by the customer.2. All pit drainage is provided by the customer.3. General lighting in the garage is provided by the customer. Klaus will supplylighting within the machine. The lighting will be connected to the machine controlbox and will be activated when the doors are open.4. Klaus will supply design assistance and will confirm in writing that the proposedmachine will fit in the space provided.
SOUND CONTROLNumerous sound control features are standard. The hydraulic power unit is mountedon rubber pads. Steel hydraulic lines are mounted with rubber pipe supports. Arubber hose isolates the power unit from the steel hydraulic lines.
Sound tests at the front of the machine show about 67dB to 69dB (A
In multifamily podium construction, normally no special construction for sound isperformed. For residential or wood frame construction, placement of the power unitis critical. Klaus designers will assist with power unit placement and other soundissues.
STRUCTURALThe machine has steel framing and is anchor bolted to the concrete garage slab withwedge anchors. The framework consists of steel columns and beams on a grid
report for details.
The platforms for the upper and lower cars consist of steel platforms that ride upand down the steel columns. The platforms for the cars at the driveway level runleft-rignt on steel rails.
The upper and lower platforms are constructed with two steel side members, threesteel cross members, ribbed steel platform material which runs from side memberto side member and one wheel stop. The platform is solid and does not allow oil orwater to drip onto the lower cars.
The machine includes several safety devices which include chain monitoring
5. Klaus will prepare shop drawings showing the location of all components.
6. The customer must close off the left and right sides of the machine with a wall orfence. The fence must be 8' high and the lower 5 feet must have no openings greaterthan 1/2" inch.
8. Klaus provides all control wiring and conduit.
1. The pit and surrounding walls, columns and beams to provide support for the
The Klaus Stack Parker 2062 provides independent access to all cars on the system. Each individual parking bay must be accessible from the drive aisle. The drive aisle
shall comply with local regulations, but is typically 24' wide. These units are sold in either a single wide or double wide configuration with parking spaces arranged on two
levels with the lower parking level stored inside the pit when the machine is in the down position. To access the lower level platform both the upper and lower platforms are
raised together until the lower level platform comes up to driveway level allowing for those cars to be then driven on or off.. The last user of the system determines if the
machine is left in the up or down position depending on which level they accessed. This system allows for full use of all the spaces on the machine and does not require a vacant
will be shown on the shop drawings and approved by the client
which runs on chain sprockets. There are safety switches that stop the machine
the 4 corners and are guided along the front support columns.
The machine comes standard with two keys per parking space. The keys areinserted into a user control box centrally placed on the system.
KEYS
SPRINKLER SYSTEM
ELECTRICAL REQUIREMENTS AND HYDRAULIC UNIT
along the back of the machine and at one point along one of the sides.
systems, and safety locks for the platforms.
space to allow for vertical movement to access a individual cars as required by the other systems. Structural 16mm dia tie rod bracing is required at four points along the back,
pattern. The machines steel columns are connected to the b uilding at four points
two at mid point and another two up near the top of the machine then also on one side another four tie rods are required on the machine, two at mid point and two near the top.
Please refer to the Stack Parker 2062 Bracing Details drawing and Merkle Engineering
The lifting mechanism for the platforms consists of hydraulic cylinders whichraises the rear of the platform. The front of the platforms are raised via a chain
in the event the chain goes loose for any reaso n. T he platforms are suspended at
weighting) noise levels (speech at foot is 68db).
environmentally friendly. The electric motor can be supplied in a 208 volt threephase (preferred) or a 240 volt single phase. Both types require a 30 amp circuit.One hydraulic power unit can run multiple lifts. KLAUS will provide the motorand motor controller. BUYER to provide a fused disconnect. BUYER to provideconduit and wiring; a.) from fused disconnect (supplied by BUYER) to motorcontroller (supplied by KLAUS); b.) from motor controller to motor (supplied byKLAUS). KLAUS to furnish and install control wiring.
Environmental conditions for the systems: Temperature range 14° to 104° F. The
TECHNICAL DATA
GENERAL DESCRIPTION
WARRANTY
WE RESERVE THE RIGHT TO CHANGE THIS SPECIFICATION WITHOUT FURTHER NOTICE
SCOPE OF WORK CLARIFICATIONS
The Klaus company reserves the right in the course of technical progress to use newer or other technologies, systems, processes, procedures or standards in the fullfillmentof their obligations other than those originally offered provided the customer derives no disadvantage from their doing so.
Standard space numbering is left to righ with the numbering sequence planned andt
The sprinklers may be mounted at the front and rear of each level if needed.
7. The customer must provide a 30 amp 3 phase 208 volt (or 240 volt single phase) circuit and fused disconnect for each machine and power must be available beforeinstallation begins.