state hall roof replacement...blkg blocking bd board blk block bldg building btm bottom bm beam betw...
TRANSCRIPT
![Page 1: STATE HALL ROOF REPLACEMENT...blkg blocking bd board blk block bldg building btm bottom bm beam betw between bit bituminous b.u.r. built-up roofing brg bearing b.s. both sides anch](https://reader034.vdocument.in/reader034/viewer/2022042419/5f35ed1cdd93ad6a69143fe6/html5/thumbnails/1.jpg)
I hereby certify that these plans and specifications have been prepared by me, or under my supervision. I further certify that to the best of my knowledge, these plans and specifications are as required by law and in compliance with the ARKANSAS FIRE PREVENTION CODE for the state of Arkansas.
Randall J. Stocks, AIA AR Registration No. 2100
401 W. CAPITOL, SUITE 402LITTLE ROCK, AR501-370-9207 501-370-9208 (FAX)
72201
ISSUE DATE
CONTENTS
SHEET NUMBER
PROJECT NUMBER
REVISIONS
CONSULTANTS:
UCA - 20- 087
4/28
/202
0 4:
24:0
3 PM
STATE HALL ROOF REPLACEMENT
T1
TITLE SHEET
STAT
E H
ALL
RO
OF
REP
LAC
EMEN
TU
NIV
ERSI
TY O
F C
ENTR
AL A
RKA
NSA
S
APRIL 28, 2020
SMA 1505W
CO
NW
AY A
RKA
NSA
S
UNIVERSITY OF CENTRAL ARKANSAS
APRIL 28, 2020
CONSTRUCTION DOCUMENTS
04/28/2020
SHEET INDEXGENERALT1 TITLE SHEETT2 GENERAL INFORMATION
DEMOLITIOND1 DEMOLITION PLAND2 DEMOLITION DETAILS
ARCHITECTURALA1 REPLACEMENT PLANA2 REPLACEMENT DETAILS
No. Date
![Page 2: STATE HALL ROOF REPLACEMENT...blkg blocking bd board blk block bldg building btm bottom bm beam betw between bit bituminous b.u.r. built-up roofing brg bearing b.s. both sides anch](https://reader034.vdocument.in/reader034/viewer/2022042419/5f35ed1cdd93ad6a69143fe6/html5/thumbnails/2.jpg)
S SOUTHS. ST. STAINLESS STEELSUSP SUSPEND(ED), SUSPENSIONS.C. SOLID CORESTL STEELSHELV SHELVINGSHEATH SHEATHINGS.E. SOUTHEASTSTRUCT STRUCTURALSTD STANDARDSTOR STORAGESTN STAIN(ED)STO STORAGESKYLT SKYLIGHTSIM SIMILARS.V. SHEET VINYLSDG SIDINGSPR SINGLE-PLY ROOFINGSCHED SCHEDULES.S. SANITARY SEWERSQ SQUARESECT SECTIONSPEC SPECIFICATIONSSYS SYSTEMSHT SHEETSF SQUARE FEET
CONST CONSTRUCTIONCEM CEMENTC COURSE(S)CB CHALKBOARD; CATCH BASINC.J. CONTROL JOINTCOL COLUMNCO. COMPANYCOND CONDENSERC.M.U. CONCRETE MASONRY UNITCTRFLSHG COUNTER FLASHINGCONC CONCRETECO CLEAN OUTCER CERAMICCONTR CONTRACTORCONT. CONTINUOUSCLG CEILINGCONN CONNECTIONCAB CABINETCOV COVER℄ CENTERLINEC.G. CORNER GUARDCLR CLEARCTR CENTERC.O. CHANGE ORDERCLO CLOSET
ABBREVIATIONS FOR CIVIL, MECHANICAL, PLUMBING, AND ELECTRICAL SHEETS ARE THE RESPONSIBILITY OF THE ENGINEERING CONSULTANTS.
W/O WITHOUTW/ WITHW.W.M. WELDED WIRE MESHW WESTWASH WASHERWD WOODWDW WINDOWW.O. WHITE OAKW.G. WALL GUARDWT WEIGHTW.F. WIDE FLANGEWP WATER PROOFWC WATER CLOSETWH WATER HEATER∠ ANGLE⌀ DIAMETER# NUMBER@ AT
V.C.P. VITRIFIED CLAY PIPEV.C.T. VINYL COMPOSITION TILEV.T.R. VENT THROUGH ROOFVEST VESTIBULEV.R. VAPOR RETARDERVERT VERTICAL
U.N.O. UNLESS NOTED OTHERWISEU.L. DES. UNDERWRITER'S LABORATORY DESINGUR URINAL
T&B TOP AND BOTTOMTREAT TREATEDTEL TELEPHONET.O.C. TOP OF CURB, TOP OF CONCRETET.O.B. TOP OF BEAMT.P. TOILET PARTITIONT.B. TACK BOARDT.B.R. TO BE REMOVEDTHK THICKT.J. TOOLED JOINTT TREADTHRESH THRESHOLDT.O.W. TOP OF WALLTOJ TOP OF JOINTTYP TYPICALT&G TONGUE & GROOVETHRU THROUGHTPD TEMPRERED.TLT TOILET
RES RESISTANTRECT RECTANGULARRET RETAININGREINF REINFORCE(MENT)RR RAILROADRFG ROOFINGRE REFERENCERM ROOMRAD RADIUSR RADIUS, RISERR.O. ROUGH OPENINGR.D. ROOF DRAINREQD REQURIEDREC RECESEDRESIL. RESILIENTREM REMOVEREV REVISEREF REFRIGERATOR
QTY QUANTITYQ.T. QUARRY TILEQTR QUARTER
POLYISO POLYISOCYANURATEPREFIN PREFINISHEDPL. LAM. PLASTIC LAMINATEP.S.I. POUNDS PER SQUARE INCHPTD PAINTEDPL PLATEPLYWD PLYWOODPREFAB PREFABRICATEDPL PROPERTY LINEPVC POLYVINYL CHLORIDEP.P. POWER POLEP.T. PRESSURE TREATEDPART PARTITIONPNL PANELPERF PERFORATEDPHOTO PHOTOGRAPHPLMB PLUMBINGP.S.F. POUNDS PER SQUARE FOOTPROJ PROJECT
OPP OPPOSITEO.C. ON CENTERO.F.O.I. OWNER FURNISHED, OWNER INSTALLEDO.F.C.I. OWNER FURNISHED, CONTRACTOR INSTALLEDO.D. OUTSIDE DIAMETEROPNG OPENINGOFF OFFICEOA OVER-ALLOVHD OVERHEADO.H. OVER HANG
N.I.C. NOT IN CONTRACTN.W. NORTHWESTN NORTHNO NUMBERN.T.S. NOT TO SCALENEC'Y NECESSARYNOM NOMINAL
MH MAN HOLEM.C.B. METAL CORNER BEADMECH MECHANICALMACH MACHINEMTL METALMANUF MANUFACTURERM MULTIPLEMID MIDDLEMEMB MEMBRANEMAX MAXIMUMMIN MINIMUMMED MEDIUMMB MARKERBOARDMEZZ MEZZANINEMTR MOTORM.E.J. MASONRY EXPANSION JOINTMTL METALMISC MISCELLANEOUSM.O. MASONRY OPENINGM.B.R. MODIFIED BITUMEN ROOFINGMATL MATERIALMOD. BIT. MODIFIED BITUMENMK MARK
LAV LAVATORYLAM LAMINATE(D)L.P. LIGHT POLELT. WT. LIGHT WEIGHTLIN LINEARLT. LIGHT
KD KNOCK DOWN
JT JOINTJAN JANITORJST JOISTJ.B. JUNCTION BOX
INSUL INSULATION, INSULATEDIN INCHINT INTERIORI.D. INSIDE DIAMETERINV INVERTINCL INCLUDE
H.R. HAND RAILHD HANDHDWD HARDWOODHDCP HANDICAP(PED)H HIGHHORIZ HORIZONTALH.M. HOLLOW METALHLW HOLLOWHT HEIGHTHYD HYDRANTHR HOURH.C. HOLLOW COREHDWR HARDWARE
GYP. BD. GYPSUM BOARDGYP GYPSUMG.B. GRAB BAR, GYPSUM BOARDGA GAUGEGALV GALVANIZEDGEN GENERALG.C. GENERAL CONTRACTORGL GLASS
F.F.E. FINISH FLOOR ELEVATIONFURR FURRINGF.E.C. FIRE EXTINGUISHER & CABINETF.V. FIELD VERIFYFIN FINISH(ED)FT FOOT / FEETF.B. FACE BRICKF.F. FINISHED FLOORFLSHG FLASHINGFLUOR FLUORESCENTFRM FRAMEFDN FOUNDATIONFLR FLOORFTG FOOTINGF.H. FIRE HYDRANTF.D. FLOOR DRAINF.R.T.W. FIRE RETARDANT TREATED WOODFLRG FLOORING
EXT EXTERIORELEV ELEVATION / ELEVATORE.W. EACH WAYEQ EQUALELEC ELECTRIC(AL)EQUIP EQUIPMENTEXIST EXISTINGEXP EXPANSIONE.W.C. ELECTRIC WATER COOLEREXH EXHAUSTE.I.F.S. EXTERIOR INSULATION & FINISH SYSTEME.J. EXPANSION JOINTEXP. JT. EXPANSION JOINTE EASTENCL ENCLOSED / ENCLOSUREEA EACHE.P.S. EXPANDED POLYSTYRENEEL ELEVATIONE.F. EXHAUST FANE.B. EXPANSION BOLT
DIAG DIAGONALDED DEDUCTIVEDP DEEPDBL DOUBLEDISP DISPENSERDIA DIAMETERDIM DIMENSIONDN DOWNDS DOWNSPOUTDR DOORD.F. DRINKING FOUNTAINDW DISH WASHERDWG DRAWINGDET DETAIL
BRK BRICKBLKG BLOCKINGBD BOARDBLK BLOCKBLDG BUILDINGBTM BOTTOMBM BEAMBETW BETWEENBIT BITUMINOUSB.U.R. BUILT-UP ROOFINGBRG BEARINGB.S. BOTH SIDES
ANCH ANCHORAGG AGGREGATEABV ABOVEA.F.F. ABOVE FINISHED FLOORALUM ALUMINUMADJ ADJUSTABLEA/C AIR CONDITIONINGACOUST ACOUSTICALASPH ASPHALTA.B. ANCHOR BOLTATTEN ATTENUATIONALT ALTERNATEADDM ADDENDUMALLOW ALLOWANCE
BUILDING
SECTION KEY
SECTION
NUMBER
SHEET NUMBER
WALL
SECTION KEY
1A1.0
1A1.0
DETAIL
SECTION KEY
1A1.0
A1.01
DETAIL REFERENCE KEY
DETAIL NUMBER
SHEET NUMBER
INTERIOR ELEVATION KEY
EXTERIOR ELEVATION KEY
ELEVATION NUMBER
SHEET NUMBER
ELEVATION NUMBER
SHEET NUMBER
DOOR SCHEDULE KEY
DOOR NUMBER
1 STOREFRONT FRAME OR
WINDOW TYPE KEY
GLASS TYPE KEYGL-3
NORTH ARROW
LEVEL LINE
PARTITION TYPE
101
1t
SPECIFICATION SECTION NUMBER(01010)
EQUIPMENT BY OWNER
(INSTALLATION BY G.C. WHERE
REQ'D.)
GENERAL AREA OF REVISION
10 NEW CONSTRUCTION KEYNOTE
SYMBOL
1REVISION
NUMBER
ROOM FINISH SCHEDULE KEYA
N
1 DEMOLITION KEY NOTE SYMBOL
EXISTING WALLS TO REMAIN
EXISTING WALLS TO BE REMOVED
NEW WALLS
A101
1
A1.01
CONCRETE
C.M.U.
FACE BRICK
STEEL
BATT INSULATION
RIGID INSULATION
WOOD - FINISHED
WOOD - ROUGH
PLYWOOD
SOIL
GYPSUM BOARD / SHEATHING
GRAVEL
EXISTING WALLS TO REMAIN
EXISTING WALLS TO BE REMOVED
NEW WALLS
STONE VENEER
SYMBOLS LEGEND ABBREVIATIONS LEGEND
1. DIMENSIONS ON DRAWINGS TERMINATE AT FACE OF MASONRY, STUDS OR CENTERLINE, UNLESS OTHERWISE NOTED. DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENCE OVER GRAPHIC REPRESENTATIONS. DETAIL DIMENSIONS TAKE PRECEDANCE OVER PLANSW AND ELEVATIONS.
2. ALL DIMENSION REVISIONS, MODIFICATIONS AND DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR REVIEW AND CLARIFICATION PRIOR TO THE INSTALLATION OF THE WORK.
GENERAL NOTES:
MATERIALS LEGEND
401 W. CAPITOL, SUITE 402LITTLE ROCK, AR501-370-9207 501-370-9208 (FAX)
72201
CONSULTANTS:
REVISIONS
ISSUE DATE
CONTENTS
SHEET NUMBER
PROJECT NUMBERUCA - 20 - 087
4/28
/202
0 4:
24:1
3 PM
STAT
E H
ALL
RO
OF
REP
LAC
EMEN
TU
NIV
ERSI
TY O
F C
ENTR
AL A
RKA
NSA
SC
ON
WAY
AR
KAN
SAS
T2
04/28/2020
GENERAL INFORMATION
APRIL 28, 2020
SMA 1505W
VICINITY MAP:
STATE HALL SITE
UCA - 20-087
No. Date
![Page 3: STATE HALL ROOF REPLACEMENT...blkg blocking bd board blk block bldg building btm bottom bm beam betw between bit bituminous b.u.r. built-up roofing brg bearing b.s. both sides anch](https://reader034.vdocument.in/reader034/viewer/2022042419/5f35ed1cdd93ad6a69143fe6/html5/thumbnails/3.jpg)
A
C
D
E
F
G
H
J
L
O
Q
R
S
T
N
K
P
U
1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 19 20
B
13
M
18
1D2
_______
2D2
_______
3D2
_______ 4D2
_______
5D2
_______
6D2
_______
8D2
_______
7D2
_______
2" VTR
2" VTR
2" VTR
2" VTR
2" VTR
2" VTR
2" VTR
2" VTR
2" VTR
2" VTR 2" VTR
4" VTR
2" VTR
2" VTR 2" VTR
2" VTR3" VTR 2" VTR
2" VTR
2" VTR
2" VTR
2" VTR
2" VTR
2" VTR
2" VTR
2" VTR
2" VTR
2" VTR 2" VTR
2" VTR 2" VTR
2" VTR 2" VTR
2" VTR
2" VTR
4" VTR
3" VTR
4" VTR
2" VTR
2" VTR
2" VTR
2" VTR2" VTR
2" VTR2" VTR
2" VTR2" VTR
2" VTR2" VTR
R.D. R.D. R.D. R.D. R.D.
RV
RV RV RV RV RV
RV RV
RV
RV
RV
RVRVRVRV
13D2
_______
15D2
_______
16D2
_______
12D2
_______
3
4
5
6 71
1
1
2
6
9
10
10
11
38' - 4"
26' - 2"12' - 2"
38' - 7"
26' - 5"12' - 2"
191'
- 3"
26' - 5"
12' - 2"
THIRD FLOOR SOUTH WING ROOF
THIRD FLOOR NORTH WING ROOF
FIRST FLOOR ROOF
FIRST FLOOR ROOF
10' -
0"
10' -
0"
39' - 0"
4' -
0"
14' -
4"
25' - 0"
52' - 0" 26' - 1"
RV RV
62" VTR
4" VTR
2" VTR
2" VTR
12
12
13
14
CORE 1
CORE 2
CORE 4
CORE 3
CORE 5
CORE 6
12
15
14D2
_______
15D2
_______
14D2
_______
1D2
_______
1D2
_______
1D2
_______
1D2
_______
1D2
_______
2D2
_______
1D2
_______
1D2
_______
401 W. CAPITOL, SUITE 402LITTLE ROCK, AR501-370-9207 501-370-9208 (FAX)
72201
CONSULTANTS:
REVISIONS
ISSUE DATE
CONTENTS
SHEET NUMBER
PROJECT NUMBERUCA - 20 - 087
4/28
/202
0 4:
23:2
8 PM
STAT
E H
ALL
RO
OF
REP
LAC
EMEN
TU
NIV
ERSI
TY O
F C
ENTR
AL A
RKA
NSA
SC
ON
WAY
AR
KAN
SAS
D1
04/28/2020
DEMOLITION PLAN
APRIL 28, 2020
SMA 1505W
N
1/8" = 1'-0"1 DEMOLITION ROOF PLAN
ROOF CORE DATADEMOLITION KEYNOTE LEGEND1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
REMOVE EXISTING MODIFIED BITUMEN ROOFING SYSTEM AND INSULATION DOWN TO EXISTING CONCRETE DECK.
REMOVE EXISTING MODIFIED BITUMEN ROOFING SYSTEM AND INSULATION DOWN TO EXISTING METAL DECK.
REMOVE EXISTING MOISTURE RELIEF VENTS - TYP.
REMOVE EXISTING VTR FLASHINGS. CLEAN VTR PIPE AND PREPARE SURFACE TO RECEIVE NEW FLASHING. FIELD VERIFY THAT VTR PIPES ARE SECURE BELOW ROOF DECK TO PREVENT ANY BROKEN PIPES FROM FALLING THROUGH.
EXISTING ROOF HATCH TO REMAIN
EXISTING CURB MOUNTED EXHAUST FANS TO BE TEMPORARILY REMOVED TO ALLOW FOR INSTALLATION OF MEMBRANE FLASHING ON THE CURB. COORDINATE DISCONNECTION OF ELECTRICAL POWER AND RECONNECTION OF ELECTRICAL POWER WITH A LICENSED ELECTRICAL SUBCONTRACTOR.
EXISTING PITCH PANS TO BE REMOVED. CUT PIPES FLUSH WITH CONCRETE DECK.
EXISTING 2 INCH BUILDING EXPANSION JOINT
EXISTING MTL ROOFING CANOPY TO REMAIN
REMOVE EXISTING MODIFIED BITUMEN ROOFING SYSTEM OVER CONCRETE CANOPY
EXISTING GUTTERS TO REMAIN. REMOVE EXISTING GUTTER STRAPS
EXISTING EXHAUST FLUE TO REMAIN. REMOVE EXISTING FLASHING. CLEAN CURB AND PREPARE SURFACE TO RECEIVE NEW FLASHING.
EXISTING ROOF DRAINS TO REMAIN (5 TYP). DISPOSE OF STRAINER.
REMOVE EXISTING MTL COPING.
REMOVE EXISTING PITCH PAN AND PIPES. PATCH METAL DECKING PER DETAIL 9/D2.
CORE 1:
CORE 2:
CORE 3:
CORE 4:
CORE 5:
CORE 6:
EXISTING ROOF - TOTAL DEPTH 2 1/2" +/-
MOD. BIT. RFG MEMBRANE1/2" PERLITE BOARD1 1/2" POLYISO INSULATION1/4" TAPERED PERLITE BOARDCONCRETE ROOF DECK
EXISTING ROOF - TOTAL DEPTH 4 3/4" +/-
MOD. BIT. RFG MEMBRANE1/2" PERLITE BOARD1 1/2" POLYISO INSULATION2" TAPERED PERLITE BOARDCONCRETE ROOF DECK
EXISTING ROOF - TOTAL DEPTH 2 1/2" +/-
MOD. BIT. RFG MEMBRANE2" POLYISO INSULATIONMETAL ROOF DECK
EXISTING ROOF - TOTAL DEPTH 4" +/-
MOD. BIT. RFG MEMBRANE2" POLYISO INSULATION1 1/2" TAPERED PERLITE BOARDMETAL ROOF DECK
EXISTING ROOF - TOTAL DEPTH 2 1/2" +/-
MOD. BIT. RFG MEMBRANE1 1/2" POLYISO INSULATIONCONCRETE ROOF DECK
EXISTING ROOF - TOTAL DEPTH 3" +/-
MOD. BIT. RFG MEMBRANE1 1/2" POLYISO INSULATIONCONCRETE ROOF DECK
GENERAL NOTES1.
2.
3.
4.
REFER TO SPECIFICATIONS SECTION 070150.19 FOR ROOFING REMOVAL PROCEDURES.
REMOVE ONLY AS MUCH ROOFING IN ONE DAY AS CAN BE MADE WATERTIGHT IN THE SAME DAY.
NOTIFY ARCHITECT OF ANY DETERIORATED OR DAMAGED WOOD BLOCKING, NAILERS OR CURBS. REPLACE AS DIRECTED BY ARCHITECT. REFER TO SECTION 012100 FOR UNIT PRICE ALLOWANCE.
NOTIFY ARCHITECT OF ANY DETERIORATED OR DAMAGED METAL ROOF DECK. REPLACE AS DIRECTED BY ARCHITECT. COST OF REMOVAL AND REPLACEMENT WILL BE ADDED TO THE CONTRACT BY CHANGE ORDER.
No. Date
![Page 4: STATE HALL ROOF REPLACEMENT...blkg blocking bd board blk block bldg building btm bottom bm beam betw between bit bituminous b.u.r. built-up roofing brg bearing b.s. both sides anch](https://reader034.vdocument.in/reader034/viewer/2022042419/5f35ed1cdd93ad6a69143fe6/html5/thumbnails/4.jpg)
EXIST GUTTER TO REMAIN
EXIST WOOD FASCIA TO REMAIN
EXIST WOOD BLKG TO REMAIN
REMOVE EXIST ROOF INSUL DOWN TO CONC DECK
REMOVE EXIST MOD BIT RFG
REMOVE EXIST 24" O.C. GUTTER STRAPS
EXIST GUTTER TO REMAIN
EXIST WOOD FASCIA TO REMAIN
EXIST WOOD BLKG TO REMAIN
REMOVE EXIST ROOF INSUL DOWN TO MTL ROOF DECK
REMOVE EXIST MOD BIT RFG
REMOVE EXIST 24" O.C. GUTTER STRAPS
EXIST STONE COPING TO REMAIN
REMOVE EXIST MTL FLASHINGS
REMOVE EXIST CANT
REMOVE EXIST MOD BIT RFG
REMOVE EXIST WOOD BLKG
REMOVE EXIST ROOF INSUL DOWN TO CONC DECK
REMOVE EXIST MTL COPING
EXIST WOOD BLKG TO REMAIN
REMOVE EXIST CANT
EXIST WOOD BLKG TO REMAIN
REMOVE EXIST MOD BIT RFG
REMOVE EXIST ROOF INSUL DOWN TO CONC ROOF DECK
REMOVE EXIST EXP JOINT BELLOW
EXIST WOOD CURB TO REMAIN
EXIST WOOD BLKG TO REMAIN
REMOVE EXIST CANT
REMOVE EXIST MOD BIT RFG
REMOVE EXIST INSUL DOWN TO CONC ROOF DECK
REMOVE EXIST MTL FLASHING
EXIST EXP JOINT FILLER TO REMAIN
EXIST WOOD CURB TO REMAIN
REMOVE EXIST CANT
EXIST WOOD BLKG TO REMAIN
REMOVE EXIST MOD BIT RFG
EXIST MTL ROOF DECK
REMOVE EXIST ROOF INSUL DOWN TO MTL DECK
REMOVE EXIST MTL FLASHING
REMOVE EXIST CANT
EXIST WOOD BLKG TO REMAIN
REMOVE EXIST MOD BIT RFG
EXIST MTL ROOF DECK
REMOVE EXIST ROOF INSUL DOWN TO MTL DECK
REMOVE EXIST MTL FLASHING
EXIST EXP JOINT FILLER TO REMAIN
EXIST WOOD CURB TO REMAIN
REMOVE EXIST CANT
EXIST WOOD BLKG TO REMAIN
REMOVE EXIST MOD BIT RFG
EXIST CONC ROOF DECK
REMOVE EXIST ROOF INSUL DOWN TO CONC DECK
EXISTING ROOFTOP EXHAUST FAN AND CURB TO REMAIN. TEMPORARILY REMOVE EXHAUST FAN TO INSTALL NEW FLASHING
EXIST CONC ROOF DECK
REMOVE EXIST CANT
REMOVE EXIST MOD BIT RFG
REMOVE EXIST ROOF INSUL DOWN TO CONC DECK
EXIST WOOD BLKG TO REMAIN
EXISTING ROOF HATCH TO REMAIN
EXISTING WOOD BLKG TO REMAIN
EXIST CONC ROOF DECK
REMOVE EXIST CANT
REMOVE EXIST MOD BIT RFG
REMOVE EXIST ROOF INSUL DOWN TO CONC DECK
EXIST PROJECTED BRICK BEYOND
REMOVE BOTTOM 3 COURSES OF PROJECTED BRICK
REMOVE EXIST MTL FLASHING AND TERMINATION BAR
REMOVE ORIGINAL BLDG MTL COUNTERFLASHING
REMOVE EXIST CANT
REMOVE EXIST MOD BIT RFG
REMOVE EXIST ROOF INSUL DOWN TO CONC DECK
EXIST CONC ROOF DECK
REMOVE EXIST MTL CONTERFLASHING
REMOVE EXIST CANT
REMOVE EXIST MOD BIT RFG DOWN TO CONC CANOPY
EXIST CONC CANOPY
REMOVE EXISTING MOD BIT RFG DOWN TO CONC DECK
REMOVE EXIST METAL GRAVEL GUARD EDGE FLASHING ON ALL SIDES
EXIST WOOD BLKG TO REMAIN
EXIST MTL FASCIA TO REMAIN
EXIST GUTTER TO REMAIN
EXIST WOOD FASCIA TO REMAIN
EXIST WOOD BLKG TO REMAIN
REMOVE EXIST ROOF INSUL DOWN TO MTL ROOF DECK
REMOVE EXIST MOD BIT RFG
REMOVE EXIST 24" O.C. GUTTER STRAPS
6" MIN.
6" MIN.
4" MIN.4" MIN.
6" MIN.
FIELD VERIFY OPENING SIZE
6" MIN.
FIELD VERIFY OPENING SIZE
EXISTING METAL DECK
NEW 1/8" THICK STEEL PLATE TO EXTEND OUT 6" FROM EDGE OF OPENING IN DECK; SET IN FULL
BED OF SEALANT AND FASTEN 4" O.C. MIN. AROUND THE
PERIMETER - FIELD PRIME / PAINT
CONTINUOUS FULL BED OF NEW SEALANT BETWEEN
EXISTING MTL DECK & NEW STEEL PLATE
NEW SPRAY FOAM IN FLUTES OF METAL DECK UNDER NEW
STEEL PLATE - APPLY SEALANT TO EXPOSED FACE
401 W. CAPITOL, SUITE 402LITTLE ROCK, AR501-370-9207 501-370-9208 (FAX)
72201
CONSULTANTS:
REVISIONS
ISSUE DATE
CONTENTS
SHEET NUMBER
PROJECT NUMBERUCA - 20 - 087
4/28
/202
0 4:
23:5
1 PM
STAT
E H
ALL
RO
OF
REP
LAC
EMEN
TU
NIV
ERSI
TY O
F C
ENTR
AL A
RKA
NSA
SC
ON
WAY
AR
KAN
SAS
D2
04/28/2020
DEMOLITION DETAILS
APRIL 28, 2020
SMA 1505W
3" = 1'-0"1 TYP. EDGE DETAIL - DEMO3" = 1'-0"2 TYP. MECH. EDGE DTL. - DEMO
3" = 1'-0"3 TYP. ENTRY EDGE DTL. - DEMO3" = 1'-0"4 TYP. ENTRY DTL. - DEMO
3" = 1'-0"5 EXPANSION JOINT #1 - DEMO3" = 1'-0"6 EXPANSION JOINT #2 - DEMO
3" = 1'-0"8 ROOF - WALL DETAIL - DEMO3" = 1'-0"7 EXPANSION JOINT #3 - DEMO
3" = 1'-0"11 TYP. CURB DETAIL - DEMO3" = 1'-0"12 ROOF HATCH DTL - DEMO
3" = 1'-0"13 ROOF-WALL AT ENTRY DTL - DEMO3" = 1'-0"14 ROOF-CANOPY DTL - DEMO
3" = 1'-0"15 CANOPY EDGE DTL - DEMO3" = 1'-0"16 WEST CANOPY EDGE DTL - DEMO
3" = 1'-0"9 METAL ROOF DECK PATCH DETAIL
No. Date
![Page 5: STATE HALL ROOF REPLACEMENT...blkg blocking bd board blk block bldg building btm bottom bm beam betw between bit bituminous b.u.r. built-up roofing brg bearing b.s. both sides anch](https://reader034.vdocument.in/reader034/viewer/2022042419/5f35ed1cdd93ad6a69143fe6/html5/thumbnails/5.jpg)
N
K
P
17 19 20
M
18
A
C
D
E
F
G
H
J
L
O
Q
R
S
T
N
K
P
U
1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 19 20
B
13
M
18
1A2
_______
2A2
_______
3A2
_______
3A2
_______
4A2
_______
5A2
_______
6A2
_______
2A2
_______
7A2
_______
8A2
_______
11A2
_______12A2
_______
13A2
_______
15A2
_______ 14A2
_______
15A2
_______
14A2
_______
16A2
_______
1
2
1/8"
/ 1'
-0"
1/8"
/ 1'
-0"
1/8" / 1'-0"
1/8"
/ 1'
-0"
1/8" / 1'-0"
1/8" / 1'-0"
1/8"
/ 1'
-0"
1/8" / 1'-0"
1/8"
/ 1'
-0"
1/8" / 1'-0" 1/8" / 1'-0"
1/8"
/ 1'
-0"
1/8" / 1'-0"
1/8"
/ 1'
-0"
1/8"
/ 1'
-0"
1/8" / 1'-0"
1/8"
/ 1'
-0"
1/8"
/ 1'
-0"
1/8"
/ 1'
-0"
2" VTR
2" VTR
2" VTR
2" VTR
9
3
3
1
4
5
6
6
7
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
THIRD FLOOR SOUTH WING ROOF
THIRD FLOOR NORTH WING ROOF
FIRST FLOOR ROOF
FIRST FLOOR ROOF
38' - 7"
26' - 5"
12' - 2"
191'
- 3"
26' - 5"12' - 2"
195' - 0"
10' -
0"
10' -
0"
10' - 0"
26' -
5"
12' -
2"
205' - 0"
11' -
11"
14' -
4"
1/8"
/ 1'
-0"
1/8"
/ 1'
-0"
52' - 0" 26' - 1"
10
2" VTR
2" VTR
2" VTR
2" VTR
2" VTR
2" VTR 2" VTR
4" VTR
2" VTR
2" VTR 2" VTR
2" VTR3" VTR 2" VTR
2" VTR
2" VTR
2" VTR
2" VTR
2" VTR
2" VTR
2" VTR
2" VTR
2" VTR
6CORE 2
R.D. R.D. R.D.
R.D.
R.D.
2" VTR 2" VTR
2" VTR 2" VTR
2" VTR 2" VTR
2" VTR
2" VTR
4" VTR
3" VTR
4" VTR
2" VTR
2" VTR
2" VTR
2" VTR2" VTR
2" VTR2" VTR
2" VTR2" VTR
2" VTR2" VTR
2" VTR
4" VTR
2" VTR
2" VTR
1/8"
/ 1'
-0"
1/8"
/ 1'
-0"
10A2
_______
TAPERED INSULATION CRICKETS
6
1A2
_______
1A2
_______
2A2
_______
1A2
_______
1A2
_______
1A2
_______
1A2
_______
1A2
_______
401 W. CAPITOL, SUITE 402LITTLE ROCK, AR501-370-9207 501-370-9208 (FAX)
72201
CONSULTANTS:
REVISIONS
ISSUE DATE
CONTENTS
SHEET NUMBER
PROJECT NUMBERUCA - 20 - 087
4/28
/202
0 4:
32:0
5 PM
STAT
E H
ALL
RO
OF
REP
LAC
EMEN
TU
NIV
ERSI
TY O
F C
ENTR
AL A
RKA
NSA
SC
ON
WAY
AR
KAN
SAS
A1
04/28/2020
REPLACEMENT PLAN
APRIL 28, 2020
SMA 1505W
N
1/8" = 1'-0"1 REPLACEMENT ROOF PLAN
ROOFING KEYNOTE LEGEND1
2
3
4
5
6
7
8
9
10
11
NEW 80 MIL TPO ADHERED ROOFING SYSTEM OVER 1/2" COVER BOARD OVER 1/8" PER FOOT TAPERED POLYISOCYANURATE INSULATION OVER 1 1/2" BASE LAYER OF POLYISOCYANURATE INSULATION OVER SELF ADHERED VAPOR BARRIER OVER EXISTING CONCRETE ROOF DECK. PRIME CONCRETE ROOF DECK. INSTALL SELF ADHERED VAPOR BARRIER OVER PRIMED CONCRETE ROOF DECK PER SPECIFICATIONS. ADHERE BASE LAYER OF INSULATION, TAPERED INSULATION AND COVER BOARD WITH INSULATION ADHESIVE PER SPECIFICATIONS. ADHERE TPO ROOF MEMBRANE TO COVER BOARD WITH ROOFING ADHESIVE PER SPECIFICATIONS.
NEW 80 MIL TPO ADHERED ROOFING SYSTEM OVER 1/2" COVER BOARD OVER 1/8" PER FOOT TAPERED POLYISOCYANURATE INSULATION OVER 1 1/2" BASE LAYER OF POLYISOCYANURATE INSULATION OVER EXISTING METAL ROOF DECK. MECHANICALLY FASTEN BASE LAYER OF INSULATION TO ROOF DECK PER SPECIFICATIONS. ADHERE TAPERED INSULATION TO BASE LAYER AND COVER BOARD WITH INSULATION ADHESIVE PER SPECIFICATIONS. ADHERE TPO ROOF MEMBRANE TO COVER BOARD WITH ROOFING ADHESIVE PER SPECFICATIONS.
NEW 80 MIL TPO ADHERED ROOFING SYSTEM OVER EXISTING CONCRETE ROOF DECK. PRIME CONCRETE ROOF DECK. ADHERE TPO ROOFING TO PRIMED CONCRETE DECK WITH ROOFING ADHEVSIVE PER SPECIFICATIONS.
NEW TPO VENT THRU ROOF (VTR) FLASHING - TYP.
EXISTING ROOF HATCH WITH NEW TPO CURB FLASHING.
EXISTING ROOF MOUNTED EXHAUST FANS. REINSTALL AND RECONNECT EXHAUST FAN AFTER NEW TPO CURB FLASHING IS INSTALLED.
EXISTING 2 INCH BUILDING EXPANSION JOINT
EXISTING GUTTERS TO REMAIN. PROVIDE NEW MILL FINISHED ALUM GUTTER STRAPS AT 24" O.C.
NEW 80 MIL TPO ADHERED ROOFING SYSTEM OVER 1/2" COVER BOARD OVER 1/8" PER FOOT TAPERED POLYISOCYANURATE INSULATION OVER 1 1/2" BASE LAYER OF POLYISOCYANURATE INSULATION OVER OVER EXISTING CONCRETE ROOF DECK. PRIME CONCRETE ROOF DECK. ADHERE BASE LAYER OF INSULATION, TAPERED INSULATION AND COVER BOARD WITH INSULATION ADHESIVE PER SPECIFICATIONS. ADHERE TPO ROOF MEMBRANE TO COVER BOARD WITH ROOFING ADHESIVE PER SPECIFICATIONS.
WALKWAY PAD
NEW TPO FLASHING AT FLUES - SIM TO DETAIL 9/A2
No. Date
11
11
![Page 6: STATE HALL ROOF REPLACEMENT...blkg blocking bd board blk block bldg building btm bottom bm beam betw between bit bituminous b.u.r. built-up roofing brg bearing b.s. both sides anch](https://reader034.vdocument.in/reader034/viewer/2022042419/5f35ed1cdd93ad6a69143fe6/html5/thumbnails/6.jpg)
3"
EXIST GUTTER TO REMAIN
EXIST WD FASCIA TO REMAIN
6" WIDE TPO COVER STRIP WITH TPO PRIMER
EXIST CONC ROOF DECK
NEW 1 1/2" RIGID INSUL BASE LAYER
NEW 1/8"/FT TAPERED INSUL
NEW 1/2" COVER BOARD
EXIST PERIM WOOD BLKG TO REMAIN - FIELD VERIFY HEIGHT
NEW TAPERED EDGE STRIP
NEW .032" ALUM EDGE FLASHING WITH A MIN. 3" FLANGE. FASTEN AT 3" O.C. WITH 1 1/4" RING SHANK NAILS - TYP
NEW SELF ADHERED VAPOR RETARDER OVER PRIMED CONC
3"NEW ALUM GUTTER BRACKETS AT 24" O.C. MAX. -TYP AT ALL GUTTERS
CONT CLEAT FASTENED AT 6" O.C. WITH 1 1/4" RING SHANK NAILS - TYP
CUT EDGE SEALANT
3"
EXIST GUTTER TO REMAIN
EXIST WD FASCIA TO REMAIN
6" WIDE TPO COVER STRIP WITH TPO PRIMER
EXIST MTL ROOF DECK
NEW 1 1/2" RIGID INSUL BASE LAYER
NEW 1/8"/FT TAPERED INSUL
NEW 1/2" COVER BOARD
EXIST PERIM WOOD BLKG TO REMAIN - FIELD VERIFY HEIGHT
NEW TAPERED EDGE STRIP
NEW ALUM EDGE FLASHING
CUT EDGE SEALANT
NEW .050" ALUM COPINGTPO MEMBRANE ATTACHED TO WOOD BLKG
NEW P.T. 2X6 ATTACHED TO EXIST STONE COPING WITH 3/8" EXP BOLTS AT 24" O.C.
CONT MTL CLEAT ATTACHED AT 3" O.C. WITH 1 1/4"RING SHANK NAILS
EXIT STONE COPING
EXIST MASONRY PARAPET
NEW 1/2" COVER BOARD
TPO BONDING ADHESIVE
TPO MEMBRANE
1 1/2" MIN HOT AIR WELD
TPO ROOFING MEMBRANE
1/2" COVER BOARD
NEW 1 1/2" RIGID INSUL BOARD
NEW 2X4 P.T. WOOD BLOCKING
EXIST CONC ROOF DECK
APPROVED FASTENERS AT 12" O.C. MAX
3/4" PRESERV. TREATED PLYWD ATTACHED TO WOOD BLKG WITH 2" RING SHANK NAILS AT 6" O.C. STAGGERED
CONT MTL CLEAT ATTACHED AT 3" O.C. WITH 1 1/4"RING SHANK NAILS
3"
4"
1' - 0"
CUT EDGE SEALANT
NEW 1X4 P.T. WOOD NAILER
NEW 1/8"/FT TAPERED INSUL
NEW .050" ALUM COPING
NEW TPO MEMBRANE OVER TOP OF PARAPET
EXTEND TPO MEMBRANE OVER FRONT OF PARAPET AND NAIL TO WOOD BLKG
NEW 2X6 P.T. CONT. WOOD BLKG - NAIL AT 6" O.C. WITH 3" RINK SHANK NAILS AND FASTEN TO STONE WITH 3/8" EXP BOLTS AT 24" O.C.
2 6 2
EXIST WOOD BLKG
CONT CLEAT ATTACHED WITH 1 1/2" RING SHANK NAILS AT 6" O.C. MAX.
5 1/
2"
1"
3"
CONT CLEAT ATTACHED WITH 1 1/2" RING SHANK NAILS AT 6" 0.C. MAX.
TPO MEMBRANE AND BONDING ADHESIVE
11 7/8" F.V.
1 1/2" MIN HOT AIR WELD
FASTENER AND SEAM FASTENING PLATE AT 12" O.C. MAX
TPO ROOF MEMBRANE
1/2" COVER BOARD
NEW 2X4 P.T. WOOD BLKG
NEW 1/8"/FT TAPERED INSUL
NEW 1 1/2" INSUL BASE LAYER
EXIST CONC ROOF DECK
CUT EDGE SEALANT
6
TPO MEMBRANE
NEW EXPANSION JOINT SUPPORT OR SPONGE TUBING
FASTENER & SEAM FASTENING PLATE AT 12" O.C. MAX.
TPO MEMEBRANE AND BONDING ADHESIVE
1 1/2" MIN HOT AIR WELD
FASTENER & SEAM FASTENING PLATE AT 12" O.C. MAX.
NEW 1/2" COVER BOARD
NEW 1/8"/FT TAPERED INSUL
EXIST WOOD BLOCKING TO REMAIN
EXISTING EXP JOINT FILLER
EXIST CONC ROOF DECK
NEW 1 1/2" RIGID INSUL BASE LAYER
2" F.V.
NEW SELF ADHERED VAPOR RETARDER OVER PRIMED CONC
CUT EDGE SEALANT
SEALANT
EXIST MTL ROOF DECK
NEW 1 1/2" RIGID INSUL BASE LAYER
NEW 1/8"/FT TAPERED INSUL
NEW 1/2" COVER BOARDTPO ROOF MEMBRANE
1 1/2" MIN HOT AIR WELD
RAWL LITE SPIKE FASTENERS WITH NEOPRENE BACKED STAINLESS STEEL WASHERS
TPO MEMBRANE AND BONDING ADHESIVE
NEW 2 PIECE PRE-FAB MTL COUNTERFLASHING - SET REGLET IN SEALANT
TERMINATION BAR
EXIST WOOD BLKG TO REMAIN
FASTENER & SEAM FASTENING PLATE AT 12" O.C. MAX.
NEW EXPANSION JOINT SUPPORT OR SPONGE TUBING
EXISTING EXPANSION FILLER
TPO STRIPPING MEMBRANE
CUT EDGE SEALANT
SEALANT
EXIST CONC ROOF DECK
NEW 1 1/2" RIGID INSUL BASE LAYER
NEW 1/8"/FT TAPERED INSUL
NEW 1/2" COVER BOARDTPO ROOF MEMBRANE
1 1/2" MIN HOT AIR WELD
RAWL LITE SPIKE FASTENERS WITH NEOPRENE BACKED STAINLESS STEEL WASHERS
TPO MEMBRANE AND BONDING ADHESIVE
NEW 2 PIECE PRE-FAB MTL COUNTERFLASHING - SET REGLET IN SEALANTTERMINATION BAR
EXIST WOOD BLKG TO REMAIN
FASTENER & SEAM FASTENING PLATE AT 12" O.C. MAX.
NEW EXPANSION JOINT SUPPORT OR SPONGE TUBING
EXISTING EXPANSION FILLER
TPO STRIPPING MEMBRANE
NEW SELF ADHERED VAPOR RETARDER OVER PRIMED CONC
CUT EDGE SEALANT
FIEL
D V
ERIF
Y
STAINLESS STEEL CLAMPING RING
WATER CUT-OFF MASTIC
EXISTING VTR - FIELD VERIFY SIZE
NEW THERMOPLASTIC NON-REINF FLASHING
HOT AIR WELDTPO ROOF MEMBRANE
NEW ROOF INSULATION
EXIST CONC OR METAL ROOF DECK -PRIME CONC DECKS
4" MIN
1" MIN
1/2"
MIN
PROVIDE NEW SELF ADHERED VAPOR RETARDER AT CONC DECKS
CUT EDGE SEALANT
EXIST EXH FAN - REMOVE TEMPORARILY TO INSTALL TPO MEMBRANE. DISCONNECT/RECONNECT BY LICENSED ELECTRICIAN
FASTENERS AT 12" O.C. MAX
TPO MEMBRANE
BONDING ADHESIVE (IF REQ'D BY TPO MANUF)
1' -
0"
EXIST ROOF CURB TO REMAIN
EXIST WOOD BLKG TO REMAIN
PRIME EXIST CONC ROOF DECK
TPO ROOF MEMBRANE
FASTENER & SEAM FASTENING PLATE AT 12" O.C. MAX
1 12/" MIN HOT AIR WELD
CUT EDGE SEALANTNEW 1/2" COVER BOARD
NEW 1/8"/FT TAPERED ROOF INSUL
NEW 1 1/2" RIGID INSUL BASE LAYER
NEW SELF ADHERED VAPOR RETARDER AT CONC ROOF DECKS
EXIST ROOF HATCH TO REMAIN
EXIST WOOD BLKG TO REMAIN
EXIST CONC ROOF DECK
OVERSIZED CLOSED-CELL FOAM BACKER ROD
BONDING ADHESIVE
FULLY ADHERED TPO MEMBRANE FLASHING
1 1/2" MIN HOT AIR WELD
CUT EDGE SEALANT
NEW 1/8"/FT TAPERED INSUL
NEW 1 1/2" RIGID INSUL BASE LAYER
TPO ROOF MEMBRANE
NEW 1/2" COVER BOARD
NEW SELF ADHERED VAPOR RETARDER OVER PRIMED CONC ROOF DECK
EXIST CONC ROOF DECK
NEW 1 1/2" RIGID INSUL BASE LAYER
NEW 1/8"/FT TAPERED INSUL
NEW 1/2" COVER BOARD
TPO ROOF MEMBRANE
NEW P.T. 2X4 CONT WOOD BLKG
1 1/2" MIN HOT AIR WELD
FASTENER & SEAM FASTENING PLATE AT 12" O.C. MAX.
TPO MEMBRANE AND BONDING ADHESIVE
NEW 2 PIECE PRE-FAB MTL COUNTERFLASHING -SET REGLET IN SEALANT
TERMINATION BAR
RAWL LITE SPIKE FASTENERS WITH NEOPRENE BACKED STAINLESS STEEL WASHERS
EXIST BRICK MASONRYEXIST BRICK PROJECTION BEYOND
1' -
4"
1' -
1"
SEALANT
NEW SELF ADHERED VAPOR RETARDER OVER PRIMED CONC
CUT EDGE SEALANT
EXIST CONC CANOPY
TPO ROOF MEMBRANE OVER PRIMED CONC
1 1/2" MIN HOT AIR WELD
FASTENER & SEAM FASTENING PLATE AT 12" O.C. MAX.
TPO MEMBRANE AND BONDING ADHESIVE
NEW 2 PIECE PRE-FAB MTL COUNTERFLASHING -SET REGLET IN SEALANT
TERMINATION BAR
RAWL LITE SPIKE FASTENERS WITH NEOPRENE BACKED STAINLESS STEEL WASHERS
EXIST BRICK MASONRY
SEALANT
CUT EDGE SEALANT
6" WIDE TPO COVER STRIP WITH TPO PRIMER
EXIST CONC CANOPY
TPO ROOF MEMBRANE OVER PRIMED CONC
3"
EXIST MTL FASCIA TO REMAIN
NEW .032 ALUM EDGE FLASHING
EXIST WOOD BLKG TO REMAIN
CUT EDGE SEALANT
EXIST GUTTER TO REMAIN
EXIST WD FASCIA AND MTL FASCIA COVER TO REMAIN
6" WIDE TPO COVER STRIP WITH TPO PRIMER
EXIST MTL ROOF DECK
NEW 1 1/2" RIGID INSUL BASE LAYER
NEW 1/8"/FT TAPERED INSUL
NEW 1/2" COVER BOARD
EXIST PERIM WOOD BLKG TO REMAIN - FIELD VERIFY HEIGHT
NEW TAPERED EDGE STRIP
NEW .032" ALUM EDGE FLASHING
CUT EDGE SEALANT
NEW RIGID INSULATION - SLOPE TO DRAIN 3/12 MAX.
RE-USE EXISTING CLAMPING RING
NEW STRAINER
EXIST ROOF DRAIN
WATER CUT-OFF MASTIC
TPO ROOF MEMBRANE
NEW 1/2" COVER BOARD
NEW 1/8/FT TAPERED INSUL
NEW 1 1/2" RIGID INSUL BASE LAYER
EXIST CONC ROOF DECK
2"
NEW SELF ADHERED VAPOR RETARDER OVER PRIMED CONC
401 W. CAPITOL, SUITE 402LITTLE ROCK, AR501-370-9207 501-370-9208 (FAX)
72201
CONSULTANTS:
REVISIONS
ISSUE DATE
CONTENTS
SHEET NUMBER
PROJECT NUMBERUCA - 20 - 087
4/28
/202
0 4:
23:1
6 PM
STAT
E H
ALL
RO
OF
REP
LAC
EMEN
TU
NIV
ERSI
TY O
F C
ENTR
AL A
RKA
NSA
SC
ON
WAY
AR
KAN
SAS
A2
04/28/2020
REPLACEMENT DETAILS
APRIL 28, 2020
SMA 1505W
3" = 1'-0"1 TYP. EDGE DETAIL - NEW3" = 1'-0"2 TYP. MECH. EDGE DTL. - NEW
3" = 1'-0"3 TYP. ENTRY EDGE DTL. - NEW3" = 1'-0"4 TYP. ENTRY DTL. - NEW
3" = 1'-0"5 EXPANSION JOINT #1 - NEW3" = 1'-0"6 EXPANSION JOINT #2 - NEW
3" = 1'-0"7 EXPANSION JOINT #3 - NEW3" = 1'-0"8 ROOF - WALL DETAIL - NEW
3" = 1'-0"9 TYP. VTR DETAIL - NEW3" = 1'-0"11 TYP. CURB DETAIL - NEW
3" = 1'-0"12 ROOF HATCH DTL - NEW
3" = 1'-0"13 ROOF-WALL AT ENTRY DTL - NEW3" = 1'-0"14 ROOF-CANOPY DTL - NEW
3" = 1'-0"15 CANOPY EDGE DTL - NEW3" = 1'-0"16 WEST CANOPY EDGE DTL - NEW
NEW 2 PIECE PRE-FAB MTL COUNTERFLASHING - SET SURFACE MTD REGLET IN SEALANT
SEALANT
RAWL LITE SPIKE FASTENERS WITH NEOPRENE BACKED STAINLESS STEEL WASHERS
TERMINATION BAR
TPO MEMBRANE AND BONDING ADHESIVE
EXISTING BRICK MASONRY WALL
FASTENER & SEAM FASTENING PLATE AT 12" O.C. MAX
1 1/2" MIN HOT AIR WELD
TPO ROOF MEMBRANE
NEW 1/2" COVER BOARD
NEW 1/8" /FT TAPERED INSUL
NEW 1 1/2" RIGID INSUL BASE LAYER
EXIST WOOD BLKG TO REMAIN
EXIST MTL ROOF DECK
3" = 1'-0"10 TPO ROOF DRAIN
CUT EDGE SEALANT
No. Date