Steam System Preventative Maintenance

Mosto Technologies Inc

Page 2: Steam System Preventative Maintenance - New York … · Steam System Preventative Maintenance ... 005 Low Pressure Drip Entrance Ramp-1 30' Mep 1" 40-415 7 BT Replace w/ 1" Mepco

Steam System Preventative Maintenance

• Annual Steam System Audit / Steam Trap Testing

• Real Time Monitoring• High Pressure steam trap monitoring• Consumption Monitoring• Chiller Plant Monitoring• PRV Monitoring utilizing digital controls

Page 3: Steam System Preventative Maintenance - New York … · Steam System Preventative Maintenance ... 005 Low Pressure Drip Entrance Ramp-1 30' Mep 1" 40-415 7 BT Replace w/ 1" Mepco

Manual Steam Trap Auditing• Mosto Technologies Inc Audit over 15,000 steam traps annually

• Typically Find a 10% average annual failure rate in each facility

• Without Incentives, typically see a 6 to 12 month payback for testing and replacement of the defective steam traps

Page 4: Steam System Preventative Maintenance - New York … · Steam System Preventative Maintenance ... 005 Low Pressure Drip Entrance Ramp-1 30' Mep 1" 40-415 7 BT Replace w/ 1" Mepco

Manual System Auditing• Check for steam leaks (wasted energy)

– Steam Traps (Trap Selection)

– Bypass valves

– Safety relief valves

– Vacuum breakers

– Insulation (pipe, valves)

Page 5: Steam System Preventative Maintenance - New York … · Steam System Preventative Maintenance ... 005 Low Pressure Drip Entrance Ramp-1 30' Mep 1" 40-415 7 BT Replace w/ 1" Mepco

Methods of Loss Detection• Visual

• Infrared Temperature Readings

• Ultrasonic Listening

• Monitoring in Real‐Time on High‐Pressure

Page 6: Steam System Preventative Maintenance - New York … · Steam System Preventative Maintenance ... 005 Low Pressure Drip Entrance Ramp-1 30' Mep 1" 40-415 7 BT Replace w/ 1" Mepco

Install Last **AnnualTag Location Elev Mfr Model PSIG Cond Recommendation Date Test Loss

001 Boiler Header Drip-1 15' Sar 1-1/2" FT15 7 OK Feb-15002 Boiler Header Drip-2 15' Sar 1-1/2" FT15 7 BT Replace w/ 1-1/2 "Sarco FT15 Feb-15 6,148.56$ 003 Main Low Pressure Supply Drip 3' Sar 1" FT15 7 OK Feb-15

004 Unit Heater-8 on Ramp 8' Mep 1" 40-415 7 OK Feb-15005 Low Pressure Drip Entrance Ramp-1 30' Mep 1" 40-415 7 BT Replace w/ 1" Mepco 40-415 Feb-15 3,732.43$ 006 Low Pressure Drip Entrance Ramp-2 30' Mep 1" 40-415 7 OK Feb-15007 UH- 9 Entrance 12' Mep 1" 40-415 7 OK Feb-15

008 ACGRM PH- 1 3' Sar 1-1/2" FT15 7 OK Feb-15009 ACGRM Supply Drip 3' Sar 3/4" FT15 7 BT Replace w/ 3/4" Sarco FT15 Feb-15 1,166.46$ 010 AC5 Communcation Room Low Pressure Drip 6' Sar 3/4" FT15 7 OK Feb-15011 AC5 PH Coil 3' Sar 3/4" FT15 7 OK Feb-15012 AC5 RH Coil 7' Sar 3/4" FT15 7 BT Replace w/ 3/4" Sarco FT15 Feb-15 1,166.46$

013 Low Pressure Drip Above HWH-1 5' Mep 1-1/4" 40-515 7 OK Feb-15014 HWH-1 Drip 1' Mep 3/4" 40-215 7 BT Replace w/ 3/4" Mepco 40-215 Feb-15 1,788.43$ 015 HWH-2 Drip 1' Mep 3/4" 40-215 7 OK Feb-15016 HWH-3 Drip 1' Mep 3/4" 40-215 7 OK Feb-15017 HWH-4 Drip 1' Mep 3/4" 40-215 7 OK Feb-15018 Low Pressure Drip Behind HWH 4' Mep 3/4" 40-215 7 OK Feb-15019 Heat Exchanger Coil 3' Mep 1" 40-415 7 BT Replace w/ Mepco 1" 40-415 Feb-15 2,410.71$

020 Unit Heater 5' Mep 3/4" 40-215 7 CO Feb-15021 HWH High Zone -1 1' Mep 3/4" 40-215 7 OK Feb-15022 HWH High Zone -2 1' Mep 3/4" 40-215 7 OK Feb-15023 Stair B Low Pressure Drip 8' Mep 1/2" 1E 7 BT Replace w/ 1/2" Mepco 1E Feb-15 2,410.71$

Boiler Room

Sample Steam Trap Database

Roof MER

G1 Garage

A-1

Lobby MER

Page 7: Steam System Preventative Maintenance - New York … · Steam System Preventative Maintenance ... 005 Low Pressure Drip Entrance Ramp-1 30' Mep 1" 40-415 7 BT Replace w/ 1" Mepco

Total Mos. In Orifice *Steam *Annual *Total AnnualTraps Trap Cond PSIG Serv. Service Size Loss (#/hr) $ Loss $ Loss

1 1-1/2" FT15 BT 7 Drip 6 0.5 123 $6,148.56 $6,148.561 3/4" 40-215 BT 7 Drip 6 0.218 23 $1,788.43 $1,788.431 1" 40-415 BT 7 Drip 6 0.313 48 $3,732.43 $3,732.432 3/4" FT15 BT 7 Coil 6 0.218 15 $1,166.46 $2,332.931 1" 40-415 BT 7 Coil 6 0.313 31 $2,410.71 $2,410.711 1/2" 1E BT 7 Drip 6 0.25 31 $2,410.71 $2,410.71

$18,823.78

Losses SummarySample Steam Trap Database

Estimated Savings

Sample Savings Summary

Page 8: Steam System Preventative Maintenance - New York … · Steam System Preventative Maintenance ... 005 Low Pressure Drip Entrance Ramp-1 30' Mep 1" 40-415 7 BT Replace w/ 1" Mepco

HP Steam Trap Monitoring

• Monitor HP steam traps (15 PSIG or Higher) in real time

• Detect when the trap passes steam or becomes cold plugged

• Email alarms upon trap failure

• Allows the building to stop HP leaks quickly to minimize losses

• 1 to 2 year payback

Page 9: Steam System Preventative Maintenance - New York … · Steam System Preventative Maintenance ... 005 Low Pressure Drip Entrance Ramp-1 30' Mep 1" 40-415 7 BT Replace w/ 1" Mepco

Basic Installation

Page 10: Steam System Preventative Maintenance - New York … · Steam System Preventative Maintenance ... 005 Low Pressure Drip Entrance Ramp-1 30' Mep 1" 40-415 7 BT Replace w/ 1" Mepco

Trap Inventory

Page 11: Steam System Preventative Maintenance - New York … · Steam System Preventative Maintenance ... 005 Low Pressure Drip Entrance Ramp-1 30' Mep 1" 40-415 7 BT Replace w/ 1" Mepco

Real Time Consumption Monitoring

• Monitor and trend steam consumption is real time

• Peak Demand Management

• Analytics to Increase Efficiency 

• M and V to verify project savings

Page 12: Steam System Preventative Maintenance - New York … · Steam System Preventative Maintenance ... 005 Low Pressure Drip Entrance Ramp-1 30' Mep 1" 40-415 7 BT Replace w/ 1" Mepco

Real Time Consumption Monitoring

Page 13: Steam System Preventative Maintenance - New York … · Steam System Preventative Maintenance ... 005 Low Pressure Drip Entrance Ramp-1 30' Mep 1" 40-415 7 BT Replace w/ 1" Mepco

Digital PRV Control• Monitor and Control Steam PRV systems digitally to ensure system efficiency

• 40 years used in Industrial Sector, Proven Technology

• Can upgrade valves and controls or just controls using current PRV stations

• Provides 3 to 5% permanent reduction in steam by reducing pressure based on OAT

Page 14: Steam System Preventative Maintenance - New York … · Steam System Preventative Maintenance ... 005 Low Pressure Drip Entrance Ramp-1 30' Mep 1" 40-415 7 BT Replace w/ 1" Mepco

PRV Monitoring

Page 15: Steam System Preventative Maintenance - New York … · Steam System Preventative Maintenance ... 005 Low Pressure Drip Entrance Ramp-1 30' Mep 1" 40-415 7 BT Replace w/ 1" Mepco

Chiller Plant Monitoring and Optimization

• Meter All 3 Refrigeration cycle points– Steam / Gas / Electric– Condenser BTU– Chilled Water BTU

• Define Chiller Efficiency 

• Maximize Efficiency w/ building during all operating conditions

Page 16: Steam System Preventative Maintenance - New York … · Steam System Preventative Maintenance ... 005 Low Pressure Drip Entrance Ramp-1 30' Mep 1" 40-415 7 BT Replace w/ 1" Mepco

Questions?