steel stud design guide vapor / dew point · pdf filesteel stud design guide vapor / dew...
TRANSCRIPT
I N S U L AT E D D R A I N A G E B OA R D
STEEL STUD DESIGN GUIDEVAPOR / DEW POINT ANALYSIS
* ®
*PATENT #5860259
TYPICAL VENEER WALL DEW POINT ANALYSIS
NOTICE: This calculation is based onthe theory of Water Vapor Migrationpresented in the ASHRAE 1993Fundamentals Handbook. Actual per-formance may vary depending on airinfiltration, workmanship, and buildingmaterials. Since the information is pro-vided without charge, The DowChemical Company assumes no obli-gation or liability for its use.
BRICK VENEER / STEEL STUD WALL (PRIOR TO 8/02 CSI ARTICLE)
R-19 BATT INSULATION
15# BUILDING PAPER
1/2” DRYWALL
6” STEEL STUDS @ 16"O.C.
1/2” DENS GLAS GOLD
2” AIRSPACE
3 5/8” BRICK
APPARENT R-VALUE ABOUT 22.16ACTUAL R-VALUE* 10.26
*TAKING INTO ACCOUNT STEEL STUD THERMAL SHORTING AND ASHRAE 90.1 CORRECTION FACTORS
OVER ONEOUNCE OF
CONDENSATIONOCCURS
WITHIN WALLPER DAY!
TYPICAL VENEER WALL DEW POINT ANALYSIS
BRICK VENEER / THERMADRAIN / STEEL STUD WALL
NOTICE: This calculation is based onthe theory of Water Vapor Migrationpresented in the ASHRAE 1993Fundamentals Handbook. Actual per-formance may vary depending on airinfiltration, workmanship, and buildingmaterials. Since the information isprovided without charge, The DowChemical Company assumes no obli-gation or liability for its use.
6” STEEL STUDS
1/2” DENS GLAS GOLD
HOUSEWRAP OR TYVEK BETWEEN DENS GLAS AND THERMADRAIN
1/2” DRYWALL
2” THERMADRAIN
5/8” TOLERANCE SPACE
3 5/8” BRICK
R-VALUE OF WALL* 14.24
SLIGHTCONDENSATION IN
AIRSPACE
TYPICAL VENEER WALL DEW POINT ANALYSIS
THERMADRAIN CAVITY WALL
3 5/8” BRICK
7 5/8” CMU
2” THERMADRAIN WITHSTYROFOAM INS.(DOW STYROFOAM)
- 2” INSULATION- 3/8” DRAINAGE MAT
2 3/8” TOTAL THICKNESS
5/8” TOLERANCE/ ANCHOR SPACE
1/4” OVERHANG
3”
R-VALUE 13.86
• R-Value of wall using Thermadrain
with Dow Styrofoam*
1 1/2” - 11.36
2” - 13.86
2 1/2” - 16.36
NOTICE: This calculation is based on thetheory of Water Vapor Migration presentedin the ASHRAE 1993 FundamentalsHandbook. Actual performance may varydepending on air infiltration, workmanship,and building materials. Since the informa-tion is provided without charge, The DowChemical Company assumes no obliga-tion or liability for its use.
SLIGHTCONDENSATION IN
AIRSPACE
1/2” DRYWALL
STEEL STUDS @ 16" O.C.
4' X 8' SHEETS OF 1/2" DENS GLAS GOLD
NO BATT INSULATION (COULD SUPPORT MOLD / MILDEW)
CLAY BRICK - ASTM C216, TYPE FBS, GRADE SW
TYPICAL SECTION
5/8” TOLERANCE / ANCHOR INSTALLA-TION SPACE
SELF ADHESIVE FLASHING & STAINLESSSTEEL DRIP EDGE BY IPCO
OPEN CELL VENT IN HEAD JOINT ON TOPOF FLASHING, RECESSED TO TOUCH MAT@ 24” O.C.
STYROFOAM WEATHERMATEPLUS HOUSEWRAP BY DOW,OR TYVEK, SHIPLAPPED OVERFLASHING AND SHEETING(BETWEEN THE DENS GLASAND THERMADRAIN)
ANCHORS
1 HOHMANN BARNARD X -SEAL ANCHOR. @1PER 2.67 FT2 OF WALL AREA WITH LEG OF2”, 2 1/2” OR 3 1/2”
OR
1 HECKMANN POSITIE WITH BARREL SCREW@1 PER 2.67 FT2 OF WALL AREA WITH 11/2”, 2”, 3” OR 3 1/2” DEEP BARREL SCREW(HOT DIPPED)
OR
1 WIRE-BOND HCL-711 ANCHOR @1 PER2.67 FT2 OF WALL AREA WITH 1 1/2”, 2”, 2 1/2” OR 3” PLATE LEGS(THERMADRAIN MUST BE CAVITY CUT 16” X96” WHEN USING THIS TIE)
4’ X 8’ SQUARE SHEETS OF THERMADRAIN® EDGE BUTTED ;PERIMETER JOINTS PRESSED INTO ABEAD OF LOW-RISE FOAM (GREATSTUFF BY DOW)
BEAD OF FOAM
CAVITY CUT
FLUSH CUT
ACTUALTHICKNESS
WALL R-VALUE WITHDOW SUPER TUFF R-C / THERMAX
1” THERMADRAIN 1 3/8” R = 10.841 1/2” THERMADRAIN 1 7/8” R = 14.14
2” THERMADRAIN 2 3/8” R = 17.342 1/2” THERMADRAIN 2 7/8” R = 20.14
3” THERMADRAIN 3 3/8" R = 23.343 1/2” THERMADRAIN 3 7/8" R = 26.34
ACTUALTHICKNESS
WALL R-VALUE WITH DOW EXTRUDED POLYSTYRENE
1 1/2” THERMADRAIN 1 7/8” R = 11.84
2” THERMADRAIN 2 3/8” R = 14.34
2 1/2” THERMADRAIN 2 7/8” R = 16.84
3” THERMADRAIN 3 3/8" R = 19.34
THERMADRAIN WITH DOW SUPER TUFF R-C / THERMAX THERMADRAIN WITH DOW EXTRUDED POLYSTYRENE
4' X 8' SQUARE SHEETS OF THERMADRAIN® EDGE BUTTED; PERIMETER JOINTS
PRESSED INTO A BEAD OF MASTIC, NP1
5/8" TOLERANCE / ANCHOR INSTALLATION SPACE
SELF ADHESIVE FLASHING & S.S. DRIPEDGE BY IPCO
OPEN CELL VENT IN HEAD JOINT ON TOP OF FLASHING, RECESSED TO
TOUCH MAT @ 2’0" O.C
STEEL STUDS @ 16" O.C.
4’ X 8’ SHEETS OF 1/2" DENS GLAS GOLD
NO BATT INSULATION (COULD SUPPORT MOLD / MILDEW)
CLAY BRICK - ASTM C216,TYPE FBS, GRADE SW
STYROFOAM WEATHERMATE PLUS HOUSE WRAP BY DOW, SHIPLAPPED OVER FLASHING & SHEETING (BETWEEN DENS GLAS AND THERMADRAIN)
BEAD OF SEALANT
TUBE STEEL
LINDAPTERHOLLO BOLT
1/2Ó DRYWALL
SECTION AT LINTEL
ThermaDrain Insulated Drainage Board
STYROFOAM WEATHERMATE PLUSHOUSEWRAP BY DOW, OR TYVEK,SHIPLAPPED OVER FLASHING ANDSHEETING (BETWEEN THE DENS GLAS AND THERMADRAIN)
DEWPOINTBLUELTR.QXD REVISED 3-19-2008
423 Joseph Drive South Elgin, IL 60177800-837-4065 847-289-2804(fax)
4' x 8' SQUARE SHEETS OF THERMADRAINEDGE BUTTED; PERIMETER JOINTS
PRESSED INTO A BEAD OF MASTIC, NP1,OR GREAT STUFF BY DOW (LOW RISE)
5/8" DRYWALL