steven e. white, director

48
DEVELOPMENT SERVICES AND CAPITAL PROJECTS DIVISION 2220 Tulare Street, Sixth Floor / Fresno, California 93721 / Phone (559) 600-4497 / 600-4022 / 600-4540 / FAX 600-4200 The County of Fresno is an Equal Employment Opportunity Employer DEPARTMENT OF PUBLIC WORKS AND PLANNING STEVEN E. WHITE, DIRECTOR DATE: January 28, 2019 3/16/18 Revision (Replaced Marlana Brown with TO: Development Services and Capital Projects, Attn: William M. Kettler, Division Manager Development Services and Capital Projects, Attn: Chris Motta, Principal Planner Development Services and Capital Projects, Current Planning, Attn: Marianne Mollring, Senior Planner Development Services and Capital Projects, Policy Planning, ALCC, Attn: Mohammad Khorsand Development Services and Capital Projects, Zoning & Permit Review, Attn: Tawanda Mtunga Development Services and Capital Projects, Site Plan Review, Attn: Hector Luna Development Services and Capital Projects, Building & Safety/Plan Check, Attn: Chuck Jonas Development Engineering, Attn: Laurie Kennedy, Grading/Mapping Road Maintenance and Operations, Attn: Frank Daniele/Wendy Nakagawa/Nadia Lopez Design Division, Transportation Planning, Attn: Mohammad Alimi/Dale Siemer Water and Natural Resources Division, Attn: Glenn Allen, Division Manager Department of Public Health, Environmental Health Division, Attn: Kevin Tsuda/Deep Sidhu/Steven Rhodes Agricultural Commissioner, Attn: Les Wright U.S. Fish and Wildlife Service, San Joaquin Valley Division, Attn: Sarah D. Yates CA Regional Water Quality Control Board, Attn: Dale Harvey Fresno County Sheriffs Department, Attn: John Zanoni, John Reynolds, Louis Hernandez, Kathy Curtis, Ryan Hushaw CA Department of Fish and Wildlife, Attn: Renee Robison, Environmental Scientist California Department of Transportation, District 6, Attn: David Padilla Dumna Wo Wah Tribal Government, Attn: Robert Ledger, Tribal Chairman Picayune Rancheria of the Chuckchansi Indians, Attn: Tara C. Estes-Harter, THPO/Cultural Resources Director Table Mountain Rancheria, Attn: Robert Pennell, Cultural Resources Director/Kim Taylor, Cultural Resources Department/Sara Barnett, Cultural Resources Department Santa Rosa Rancheria Tachi-Yokut Tribe, Attn: Hector Franco, Director/Shana Powers, Cultural Specialist San Joaquin Valley Unified Air Pollution Control District (PIC-CEQA Division), Attn: PIC Supervisor Sierra Resource Conservation District, Attn: Terry Sandridge Fresno County Fire Protection District, Attn: Chris Christopherson, Battalion Chief FROM: Jeremy Shaw, Planner Development Services and Capital Projects Division JS

Upload: others

Post on 24-Oct-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: STEVEN E. WHITE, DIRECTOR

DEVELOPMENT SERVICES AND CAPITAL PROJECTS DIVISION

2220 Tulare Street, Sixth Floor / Fresno, California 93721 / Phone (559) 600-4497 / 600-4022 / 600-4540 / FAX 600-4200 The County of Fresno is an Equal Employment Opportunity Employer

DEPARTMENT OF PUBLIC WORKS AND PLANNING

STEVEN E. WHITE, DIRECTOR DATE: January 28, 2019 3/16/18 Revision (Replaced Marlana Brown with TO: Development Services and Capital Projects, Attn: William M. Kettler, Division

Manager Development Services and Capital Projects, Attn: Chris Motta, Principal Planner Development Services and Capital Projects, Current Planning, Attn: Marianne Mollring, Senior Planner Development Services and Capital Projects, Policy Planning, ALCC, Attn: Mohammad Khorsand Development Services and Capital Projects, Zoning & Permit Review, Attn: Tawanda

Mtunga Development Services and Capital Projects, Site Plan Review, Attn: Hector Luna Development Services and Capital Projects, Building & Safety/Plan Check, Attn: Chuck Jonas Development Engineering, Attn: Laurie Kennedy, Grading/Mapping Road Maintenance and Operations, Attn: Frank Daniele/Wendy Nakagawa/Nadia

Lopez Design Division, Transportation Planning, Attn: Mohammad Alimi/Dale Siemer Water and Natural Resources Division, Attn: Glenn Allen, Division Manager Department of Public Health, Environmental Health Division, Attn: Kevin Tsuda/Deep Sidhu/Steven Rhodes

Agricultural Commissioner, Attn: Les Wright U.S. Fish and Wildlife Service, San Joaquin Valley Division, Attn: Sarah D. Yates CA Regional Water Quality Control Board, Attn: Dale Harvey Fresno County Sheriffs Department, Attn: John Zanoni, John Reynolds, Louis

Hernandez, Kathy Curtis, Ryan Hushaw CA Department of Fish and Wildlife, Attn: Renee Robison, Environmental Scientist California Department of Transportation, District 6, Attn: David Padilla

Dumna Wo Wah Tribal Government, Attn: Robert Ledger, Tribal Chairman Picayune Rancheria of the Chuckchansi Indians, Attn: Tara C. Estes-Harter, THPO/Cultural Resources Director Table Mountain Rancheria, Attn: Robert Pennell, Cultural Resources Director/Kim Taylor, Cultural Resources Department/Sara Barnett, Cultural Resources

Department Santa Rosa Rancheria Tachi-Yokut Tribe, Attn: Hector Franco, Director/Shana Powers, Cultural Specialist

San Joaquin Valley Unified Air Pollution Control District (PIC-CEQA Division), Attn: PIC Supervisor Sierra Resource Conservation District, Attn: Terry Sandridge Fresno County Fire Protection District, Attn: Chris Christopherson, Battalion Chief

FROM: Jeremy Shaw, Planner Development Services and Capital Projects Division

JS

Page 2: STEVEN E. WHITE, DIRECTOR

2

SUBJECT: Initial Study Application No. 7577, Unclassified Conditional Use Permit Application No. 3635

APPLICANT: AT&T Mobility DUE DATE: February 11, 2019 The Department of Public Works and Planning, Development Services and Capital Projects Division is reviewing the subject applications proposing to allow the installation of a 61-foot tall unmanned telecommunication tower, with an artificial broadleaf tree design, including six antennas, 12 Remote Radio Units (RRUs), and 3 surge protectors, within a 25-foot by 25-foot lease area, surrounded by a 6-foot tall chain link fence, topped with barbed wire, on a 431.6-acre parcel; along with related ground equipment including an 8-foot by 8-foot concrete walk-in equipment cabinet, with a wall mounted HVAC, a 30 KW diesel standby generator with a 190 gallon fuel tank, mounted on a concrete pad, and a 200 Amp Service Meter and Disconnect mounted on an H-Frame, within a separate 20-foot by 15-foot lease area, located on an adjacent 2.00-acre parcel, surrounded by a six-foot tall chain link fence topped with barbed wire. The two separate lease areas will be located approximately 450 feet apart and connected by a proposed 20-foot wide access and utility easement, which provides access to the sites from Millerton Road, and includes underground power and telco cables. The subject parcels are located on the south side of Millerton Road, between Rusty Spur Lane and State Route 168 (Morgan Canyon Road), in the AE-40 (Exclusive Agricultural, 40-acre minimum parcel size) Zone District (APN’s 138-070-66 and 138-070-69) (SUP. DIST. 5). The Department is also reviewing for environmental effects, as mandated by the California Environmental Quality Act (CEQA) and for conformity with plans and policies of the County. Based upon this review, a determination will be made regarding conditions to be imposed on the project, including necessary on-site and off-site improvements. We must have your comments by February 11, 2019. Any comments received after this date may not be used. NOTE - THIS WILL BE OUR ONLY REQUEST FOR WRITTEN COMMENTS. If you do not have comments, please provide a “NO COMMENT” response to our office by the above deadline (e-mail is also acceptable; see email address below). Please address any correspondence or questions related to environmental and/or policy/design issues to me, Jeremy Shaw, Planner, Development Services and Capital Projects Division, Fresno County Department of Public Works and Planning, 2220 Tulare Street, Sixth Floor, Fresno, CA 93721, or call (559) 600-4207, or email [email protected]. G:\4360Devs&Pln\PROJSEC\PROJDOCS\CUP\3600-3699\3635\ROUTING\CUP 3635 Routing Ltr.doc Activity Code (Internal Review):2384 Enclosures

Page 3: STEVEN E. WHITE, DIRECTOR

Date Received: / -17 - / { Fresno County Department of Public Works and Planning

MAILING ADDRESS: Department of Public Works and Planning Development Services and Capital Projects Division 2220 Tulare St., 61

h Floor Fresno, Ca. 93721

APPLICATION FOR:

0 Pre-Application (Type)

0 Amendment Application

0 Amendment to Text

~ Conditional Use Permit

0 Variance (Class )/Minor Variance

0 Site Plan Review/Occupancy Permit

No ShooUDog Leash Law Boundary

0 Director Review and Approval

0 for 2nd Residence

0 Determination of Merger

0 0 0

Agreements

ALCC/RLCC

Other 0 0 General Plan AmendmenUSpecific Plan/SP Amendment)

OFFICE USE ONLY (PRINT FORM ON GREEN PAPER)

City

LOCATION: (Applicat ion No.)

Southwest corner of Tulare & "M" Streets, Suite A Street Level Fresno Phone: (559) 600-4497

DESCRIPTION OF PROPOSED USE OR REQUEST:

At I ow a. 61 '-1-41/ writ./ es~ CP/111 MUY/ I c.Mt(!,.,,,, .frn,JtJy w ilh/~ I>..

, i) $1~ ../ovt lev,e a~ 911 ~ L{?;/. t 0-aLf(. [YAHaf; ~ re/Pied 'J. ~vi/Jr~euf. v.;;H,,r, 0\.. ~oo ~4<J:;#~_r.,.+ l~ ~I QYI CoJ'fl Cfr/;~r 2.~-4L_/t, f a/t;tt t , ;,, °11"! 1J £.... 'I 1J z()(;]b D~tir o .

~,ct\ Phone j'S~l~

Zip Phone

UTILITIES AVAILABLE: Application Type I No. : Gc.J~ '3~';$' Fee:$91 t2.') . o0

WATER: Yes DI No~ Application Type I No.: Fee: $

Application Type I No. : Fee: $

Application Type I No.: Fee: $ Pffillnitial Study No.: I~ 77i71 Fee: $ 5, 15'/. t?O

Ag Department Review: Fee:$ 91·"" Health Department Review: Fee: $ 'l'! 2. tlfJ

Received By: ~. Invoice No. : /It;' 707 TOTAL: $ f'; /12. Pf)

STAFF DETERMINATION: This permit is sought under Ordinance Section :

Related Application(s):. ___________________ _

Zone District : ______________________ _

Parcel Size: _______________________ _

G:\43600cvs&Pln\PROJSEC\PROJDOCS\TEMPLATES\PWandPlanningApplicationF-8Rvsd-2015060! .docm

Agency: ___________ _

SEWER: Yes DI No~

Sect-TwplRg: __ - T __ SIR __ E

APN #

APN #

APN #

APN #

-- --

over. .....

(PRINT FORM ON GREEN PAPER)

Page 4: STEVEN E. WHITE, DIRECTOR

D6Yelopment Services P A 1 · t. R . Email to: Maria Kim re- pp /£(!) lOn eV/eW n [email protected]

1 ( · / -,

Department of Publfc Wotks and Planning Capllal PnJjecls Division

NUMBER: 39616 APPLICANT: Complete Wireless

PHONE: (916) 247-6087 PROPERTY LOCA TJON: SEC 14 & 15 - 11122 APN: 138 070 66 ALCC: No_Yes # 109 VIOLATION NO.-------CNEL: No_Jf_ Yes_{level} LOW WATER: No Yes_K WITHIN Yz MILE OF CITY: No X Yes ___ _ ZONE DISTRICT: AE-40 ; SRA: No __ Yes X HOMES/TE DECLARATION REQ'D.: No_K__Yes_ LOT STATUS:

Zoning: ( X) Conforms; ( ) Legal Non-Conforming Jot; ( ) Deed Review Req'd (see Form #236) Merger: May be subject to merger: No_Jf_ Yes_ ZM# Initiated __ In process ___ _ Map Act: ( ) Lot of Rec. Map; ( ) On '72 rolls; ( X) Other PLA 6283; ( ) Deeds Req'd (see Form #236)

SCHOOL FEES: No_K Yes_ DISTRICT: PERMIT JACKET: No X Yes_ FMFCD FEE AREA: ( X) Outside ( ) District No.: FLOOD PRONE: No Yes...A_ PROPOSAL UCUP to allow a new wireless communication tower- will be 61' tall and a faux tree design

GENERAL PLAN POLICIES: G::7-f 7 1;;/e: 1 PROCEDURES AND FEES: LAND USE DESIGNATION: {5Jll11e. l~nd ( )GPA: _______ ( }MINOR VA: _____ _ COMMUNITY PLAN: ( )AA: ( x:')HD: qq 1 , & C?

REGIONAL PLAN: ?ieift\ !Vey=#. (><)CUP: q, t.2'3. tJO ( x JAG COMM:___.1~· 3.._._o_tJ __ _ >

SPECIFIC PLAN: ( )DRA: ( )ALCC: ______ _ SPECIAL POLICIES: ( )VA: (¥ JIS!PER*: S .t '21. vo

SPHERE OF INFLUENCE: ( }AT: ( )Viol. (35%): _____ _ ANNEX REFERRAL (LU-G17/MOU):. _____ ( }TT: ( )Other: __ ~-----

Filing Fee:$ /5, 3f/. o-o COMMENTS: W)f/11111svM 4-f- &nh-J Pre-Application Fee: - $247.00

ft 1&7 Total County Filing Fee: J /f?-, //2 . CJ.?

FILING REQUIREMENTS: OTHER FILING FEES:

Land Use Applications and Fees ( )r) Archaeological Inventory Fee: $75 at time of filing {)() r XJ ( >()

This Pre-Application Review form (Separate check to Southern San Joaquin Valley Info. CenterJ Copy of Deed I Legal Description ( X) CA Dept. of Fish & Wildlife (CDFW):C$50J ($50+$2#89.75} I 'l17'i'f. 75"

(){) ( ) O( J (X')

Photographs (Separate check to Fresno County Clerk for pass-thru to CDFW. Letter Verifying Deed Review Must be paid prior to IS closure and prior to setting hearing date.) JS Application and Fees* *Upon review of project materials, an Initial Study (IS) with fees may be required. Site Plans - 4 copies {folded to 8.5"X11'~ + 1 - 8.5"x11" reduction

(XJ {>(}

Floor Plan & Elevations - 4 copies {folded to 8.5"X11'J + 1 - 8.5"x11" reduction Project Description I Operational Statement {Typed)

( ) rYJ ( ) ( )

Statement of Variance Findings PLU# 113 Fee: $247.00 Statement of Intended Use (ALCC) Note: This fee will apply to the application fee Dependency Relationship Statement ifthe application is submitted within six (6) Resolution/Letter of Release from City of months of the date on this receipt.

Referral Letter# _______ _

BY: ,"J[,(l.,r; 111 V 5"~~ PHONE NUMBER: (559C/9tJ - L/.1 CJ 7

DATE: /2.,-/Lf - ll'

NOTE: THE FOLLOWING REQUIREMENTS MAY ALSO APPLY: ( ) COVENANT ( ) SITE PLAN REVIEW ( ) MAP CERTIFICATE (A') BUILDING PLANS ( ) PARCEL MAP ( X) BUILDING PERMITS ( ) FINAL MAP ( ) WASTE FACILITIES PERMIT ( ) FMFCD F~ ( ) SCHOOL FEES (X) ALUC~ {,>() OTHER(seereverseside) OVER ..... . . Rev 11 /15/17 F226 Pre-Application Review

Page 5: STEVEN E. WHITE, DIRECTOR

CVL0314 7 Marshall Junction (SFR 1)

MAILING ADDRESS: LOCATION: Department of Public Works and Planning Development Services Division

Southwest comer of Tulare & "M" Streets, Suite A Street Level

2220 Tulare Street, 61° Floor Fresno Phone: (559) Fresno, CA 93721

APPLICATION FOR:

D Amendment Application

0 Amendment to Text

IBJ Conditional Use Permit

D Director Review and Approval

D Site Plan Review/Occupancy Permit

D Variance/Minor Variance

D No Shoot/Dog Leash Law Boundary D Other _________ _

0 ALCC/RLCC

D Pre-Application (Check Type)

D General Plan Amendme.nt

D Specific Plan Amendment

D Specific Plan

D Determination of Merger

D Agreements

DESCRIPTION OF PROPOSED USE OR REQUEST: AT&T proposes a new telecommunications {iM{h\i in order to produce high speed broadband

internet and wireless services to the

surrounding under-served community. Please see Project Support Statement for

additional details.

PLEASE TYPE OR PRINT IN BLACK INK. Answer all questions completely. Attach required site plans, forms, statements and deeds as specified on the Pre-Application Review.

LOCATION OF PROPERTY: ______ S_o_ut_h __________ side of Old Millerton Road

between Rusty Spur Lane and Hwy 168 (Morgan Canyon Road)

Street address No Site Address

APN 138-070-66 & 138-070-069 Parcel size 431.60 & 1.98 acres Sec-Twp I Ag.

LEGAL DESCRIPTION: (Attach Copy of Deed)

I, (signature), declare that I am the owner, or authorized representative of the owner, the above desc ed operty and that the application and attached documents are in all respects true and correct to the best of my knowledge. The foregoing declaration is made under penalty of perjury.

Jervy Smith, Smith Foothill Ranch LLC 8703 N. Del Mar Avenue Fresno 93711 . Owner (Print or Type) Address City Zip

Complete Wireless Consulting on behalf of AT&T Mobility 2009 V Street Sacramento 95818 Applicant (Print or Type) Address City Zip

Representative (Print or Type). Address City Zip

Phone

916-247-6087 ----Phone

Phone

OFFICE USE ONLY WHEN VALIDATED

Application Type I No.: Fee: ___ _ PLU ---Application Type I No.: Fee: ___ _ PLU __ _ Application Type I No.: Fee: ___ _ PLU __ _ Application Type I No.: Fee: ___ _ PLU __ _ Initial Study No.: Fee: ___ _ PLU __ _

Environmental Review: Fee: ---- PLU __ _ Health Department Review: Fee: ___ _ PLU ----Received by: -·----This permit is sought under Ordinance Section:

Related applications: -------------·-------­Drafting verification: Zone District:

APN# APN# APN# Sec. Twp. Rg. __ _ Parcel Size -------

THIS APPLICATION IS YOUR RECEIPT

GREEN -- DEPARTMENT COPY WHITE -- APPLICANT COPY CANARY

F·S (R05·03)

Page 6: STEVEN E. WHITE, DIRECTOR

(o5J

111912016

9 10 1 15

AP-109

0 160.00Ac.

C.P.M. W. 99-23

AP-33 @

45.25Ac.

SUBDIVIDED LAND IN SEC'S. 13, 14, 15,22,23&24, T 11S., R.22E., M.D.B.& M. Tax Rate Area 199-002 199-020

(38) ;/.,s !/l 84J ; ;; -&~ ; ci - - -- - ------ - -- - - - - - - - - ---- - - --- ;~;8

10Ac. 10Ac. Q:: I AP-109

@ 431.60Ac.

713-890-48

(34)

DRY

I I I I I I I I I I I I I I I I I I I I I I I I I I I I

138-07

t 1" = 1200'

~----~---~Res~G~~~o- - - -- - - -~----j;i;~:--------------------~1~,~~----- -- - - ----- ---~ 2 24 \" 24f19

AP-144

@ 640.00Ac.

AP-144

@ 275.80Ac.

AP-144

® 360.00Ac.

AP-6199

@ 44.20Ac.

21 22 2 23 28 27 27 26

Agricultural preserve Certificate of Parcel Map Waiver, No. 99-23 Doc. 216172, 9-15-05

' I I I I I I

(2~ T I I I I I I I I I I I I I I I I I I I I

LLilLLi ~I~ ct1ct

~6~: -------------------------------- ;$~

Parcel Map No. 4197 - Bk. 33, Pgs. 38-40 Record of Survev - Bk 49 Pas dn-4 t . . -'Note : 'Assessor'~Brock'Numbers Shown m Ellipses

Assessor's Parcel Numbers Shown in Circles

Assessor's Map Bk. 138 - Pg. 07 County of Fresno, Calif.

0

gasamano
Polygon
Page 7: STEVEN E. WHITE, DIRECTOR

!(

!(

!(

!(

!(

MADERA COUNTY

·|}þ168

DOGCRE E K

FRIANT-KERN CANAL

S AN JOAQ

UIN

RIVE

R

LITTLE DRY CREEK

Prather

Marshall Station

Humphrey's Station

AUBE

RRY

TOLLH

OUSE

LODGE

MILLERTON

PITTM

AN H

ILL

SAMPLE

WATTS

VALLE

Y

MARI

NA MILLERTON

LOCATION MAPCUP 3635

Prepared by: County of Fresno Department of Public Works and Planning GS

µ0 1 2 3 40.5

Miles

SUBJECT PROPERTY

Page 8: STEVEN E. WHITE, DIRECTOR

GOLDEN HILLS SCH DIST

GRZ640AC.

GRZ431.6AC.

GRZ360AC.

GRZ275.8AC.

GRZ160AC.

GRZ160AC.

GRZ80

AC.

GRZ80

AC.

GRZ80

AC.

GRZSF2

111.96

GRZSF140

GRZ45.25AC.

GRZ53.29AC.

SF2

SF136.83AC.

GRZ37.89AC.

SF120

AC.

SF120

AC.

SF120

AC.

SF1GRZ20.08

SF120.02AC.

V18.46AC.

V10

AC.

SF110

AC.

V10

AC.

V10

AC.

SF110

AC.

SF110

AC.

SF110

AC.

SF110

AC.

SF110

AC.

SF19.99AC.

SF19.4AC.

SF19.99AC.

SF19.99AC.

SF111.24AC.

V11.21AC.

SF18.4AC.

SF15.25AC.

SF15

AC.

SF14.77AC.

SF25

AC.

GRZ1.98AC.

GRZ1.45AC.

EXISTING LAND USE MAPCUP 3635

Subject Property

Ag Contract Land

LEGEND:

Department of Public Works and PlanningDevelopment Sevices Division

Map Prepared by: GSJ:GISJCH\Landuse\

µ0 1,000 2,000 3,000 4,000500

Feet

LEGEND

GRZ - GRAZINGSF#- SINGLE FAMILY RESIDENCEV - VACANT

Page 9: STEVEN E. WHITE, DIRECTOR

!(

AL40

AE40

AE40AE40

AE40

AE40

AL40

AL40

RR

RR

RC160

AL40

AE40

RR5

AE40

AL40

AL40

CMRR

RCC

AL40AE40

AL40

·|}þ168

LITTLE DRY CREEK

Marshall Station

MILLERTON

AUBE

RRY

MORGAN CANYON

WHITE THORNE

FRONTIER

NICHOLAS

COYOTE HILLS

GOOS

EBER

RY

GARLOCK

BLUE OAK

KNOX

LOPE

R VA

LLEY

HOME

STEA

DVINEYARD

SKYLAN

FERGUSON

BLUE DRAKE

BOUL

DER

AZTE

C

EXISTING ZONING MAPCUP 3635 STR 14- 11/22

0 2,800 5,600 8,400 11,2001,400Feet

Prepared by: County of Fresno Department of Public Works and Planning GS

µ

SUBJECT PROPERTY

Page 10: STEVEN E. WHITE, DIRECTOR

OPERATIONAL STATEMENT

AT&T Mobility Site “CVL03147 Marshall Junction”

No Site Address, Prather, CA 93656

APN: 138-070-66 (tower) & 138-070-69 (ground equipment)

Nature of the operation--what do you propose to do? Describe in detail.

AT&T is proposing communications facility for this location. This is an unmanned, remotely monitored facility

that operates 24 hours per day, 7 days per week, 365 days per year, to provide high speed broadband and cellular

coverage to this underserved area of Fresno County.

This application seeks to provide the broadband internet and wireless service to the same target area as depicted in

a previous Fresno County Planning application, CUP3572, Initial Study No. 7275. The project proposed on that

previous location at 15899 Garlock Lane (APN: 138-371-45) was denied by the Planning Commission on December

14, 2017 and AT&T chose not to pursue an appeal of that denial. Instead, AT&T sought to find an alternative

location that may provide the same service objectives targeted by the first location on Garlock Lane.

AT&T has proposed a shorter tower on the hillside of an undeveloped parcel, located just south of Millerton Road.

AT&T now returns to the Fresno County Planning Commission with the revised location to provide services needed

to the surrounding rural community. Due to the rural nature of the project, there is no site address and one is

requested from Fresno County in order to help identify the site.

Operational time limits: This unmanned facility will provide service 24 hours a day, 7 days a week.

Number of customers or visitors: The facility will not be open for visitors or customers.

Number of employees:

The site is an unmanned facility. A service technician will visit the site on an average of once per month for routine

maintenance. The site will be entirely self-monitored and connected directly to a central office where sophisticated

computers alert personnel to any equipment malfunction. Because the wireless facility will be unmanned, there

will be no regular hours of operation and no impacts to existing local traffic patterns. No water or sanitation services

will be required.

Service and delivery vehicles: This site will have a technician visit an average of once a month.

Access to the site:

Access comes directly off Millerton Road. All ground equipment will be located just off Millerton Road, setback

by 40’.

Number of parking spaces for employees, customers, and service/delivery vehicles.

This project has been designed to take up no parking spaces. There is adequate space for a technician to park during

monthly site visits. Although the facility will be in constant operation, there will be no regular full time employees,

customers and/or service staff that will report to the facility on a daily basis. An AT&T facilities maintenance

employee will perform monthly site visits to the location.

Are any goods to be sold on-site?

If so, are these goods grown or produced on-site or at some other location? No. Not applicable.

Page 11: STEVEN E. WHITE, DIRECTOR

Operational Statement – CVL03147 Marshall Junction

2

What equipment is used? Included as part of this wireless facility will be the following:

Two Lease Areas:

20’ x 15’ ground equipment lease area on APN 138-070-69

12 remote radio heads

Walk-in cabinet, mounted on concrete slab

30KW diesel standby generator, mounted on a concrete slab

6’ chain link fence with access gate.

25’ x 25’ fenced tower lease area on APN 138-070-66

61’ tall faux-broadleaf tree with (2) Antenna sectors with (3) antennas per sector

What supplies or materials are used and how are they stored? Please see above.

Does the use cause an unsightly appearance? Noise? Glare? Dust? Odor? Please review the Site Plans and Photo Simulations, which have been included as part of this project, regarding

project appearance.

The only two sources of sound associated with the proposed facility will be: 1) either a door mounted heat exchanger

or an air conditioner within the walk-in cabinet, and 2) the standby generator, which will be operated for an average

of 30 minutes per month for maintenance purposes. The generator will be utilized during power outages. Neither

of these sources of sound will exceed the acceptable noise levels for the zoning designation.

There are no sources of glare, dust, or odor associated with the operations of the project.

List any solid or liquid wastes to be produced. Not applicable.

Estimated volume of water to be used (gallons per day). Not applicable.

Describe any proposed advertising including size, appearance, and placement.

Not applicable.

Will existing buildings be used or will new buildings be constructed? A new 61’ tall faux-broadleaf tree will be constructed at the location, after being transported in large sections. The

walk-in cabinet and generator will be transported directly to the proposed tower location.

Explain which buildings or what portion of buildings will be used in the operation.

An equipment shelter will be used to house technology equipment at this location.

Will any outdoor lighting or an outdoor sound amplification system be used?

No sound amplification will be used. There will be down-titled, hooded lights on timers for maintenance and safety

purposes.

Landscaping or fencing proposed? A 6’ security fence will surround the perimeter of both the 25’ x 25’ and 20’ x 15’ lease areas.

Any other information that will provide a clear understanding of the project or operation.

In order to provide power to the proposed AT&T facility, power will be run approximately 0.8 miles to the project

lease area from Morgan Canyon Road. All power and telco runs will be undergrounded whenever possible.

Page 12: STEVEN E. WHITE, DIRECTOR

PROJECT SUPPORT STATEMENT

AT&T MOBILITY

Site Name: CVL03147 Marshall Junction

Site Address: No Site Address, Prather, CA 93656

APN: 138-070-66 & 138-070-69

INTRODUCTION

AT&T is seeking to improve communication services in Fresno County by providing high-speed

internet service to the underserved communities, identified by the Federal Communications

Commission (FCC). The facility has been designed and sited to provide services to rural

residences up to about a 1.5 miles from the proposed tower location.

HISTORY

AT&T’s current application seeks to provide broadband internet and wireless service to the same

target area as depicted in a previous Fresno County Planning application, CUP3572, Initial Study

No. 7275. The project, proposed on a previous location at 15899 Garlock Lane (APN: 138-371-

45), was denied by the Planning Commission on December 14, 2017 and AT&T chose not to

pursue an appeal of that denial. Instead, AT&T sought to find an alternative location that may

provide the same service objectives targeted by the first location on Garlock Lane.

AT&T has proposed a shorter tower on the hillside of an undeveloped parcel, located just south

of Millerton Road. AT&T now returns to the Fresno County Planning Commission with the

revised location to provide services needed to the surrounding rural community. Due to the rural

nature of the project, there is no site address and one is requested from Fresno County in order to

help identify the site.

PROJECT LOCATION

This project is located on two (2) parcels, both owned by the Smith Foothill Ranch LLC, and

both zoned AE-40 (Exclusive Agriculture). The contiguous properties are undeveloped and are

currently used for cattle grazing.

Proposed Project Location

Page 13: STEVEN E. WHITE, DIRECTOR

Project Support Statement – CVL03147 Marshall Junction

Site Address: No Site Address, Prather, CA 93656 (APN: 138-070-66 & 138-070-69)

2

Two Lease Areas Required

Due to the extreme grade of the proposed location, the placement of both tower and associated

equipment on the hill required preliminary review by the Fresno County Fire Prevention

Department. Based on the improvement required to provide a Fire Prevention compliant access,

road, the access road would require major switchbacks, the removal of all trees on the face of the

hill, the construction of no less than three (3) retaining walls, fire turnarounds, and the placement

of at least 8,000 cubic ft. of fill. Due to the disruption to the hill’s landscape and the property

owner’s dismay, AT&T contacted Battalion Chief Christopher Christopherson for preliminary

review. Based on his input, the placement of the cabinets and generator at the base of the hill,

just south of Millerton Road, would eliminate the need for the above fire prevention

requirements. Therefore, in order to preserve the integrity of the hillside, AT&T chose to split

the lease areas into two (2) locations—equipment at the base of the hill for easy access by public

agencies and tower at the top of the hill in order to offer AT&T’s radio access network (RAN)

engineer the height and elevation needed to provide coverage to the target area.

The proposed facility is comprised of two (2) lease areas. The first area will be enclosed by a

chain link fence just off of Millerton Road, abiding by the setbacks of 35’ (front), 20’ (sides),

and 20’ (rear) in the zone. The first area will be 15’ x 20’ to house AT&T’s outdoor equipment

cabinets and generator. All equipment will be enclosed by a 6’-tall chain link fence.

First Lease Area

Page 14: STEVEN E. WHITE, DIRECTOR

Project Support Statement – CVL03147 Marshall Junction

Site Address: No Site Address, Prather, CA 93656 (APN: 138-070-66 & 138-070-69)

3

Second Lease Area

PROJECT DESIGN

The proposed unmanned telecommunications facility will a 61’-tall faux-broadleaf tree on the

hillside. The height of the monopole itself will be 57’ to the top of the steel with the antennas

placed at a centerline of 50’. The additional height is required in order to provide a natural taper

to the top of the tree.

Associated equipment includes six (6) panel antennas, two (2) antenna sectors with three (3)

antennas per sector, with AT&T’s walk-in cabinet and generator. The facility will be enclosed by

a 6’ tall chain link fence. Power and telecommunications cables will be installed underground

within the lease area. The unmanned facility will provide high-speed internet access and

wireless services 24 hours a day, 7 days a week.

Looking West from Millerton Road

Page 15: STEVEN E. WHITE, DIRECTOR

Project Support Statement – CVL03147 Marshall Junction

Site Address: No Site Address, Prather, CA 93656 (APN: 138-070-66 & 138-070-69)

4

Looking South from Oak Creek Road

This parcel and lease area location were chosen in compliance with Fresno County’s Wireless

Communication Guidelines, item no. 7, regarding the siting of towers in rural agricultural areas.

The proposed facility height complies with the County’s development standards for wireless

facilities in the Exclusive Agricultural zoning designation. Because of the surrounding

topography and breadth of the coverage area, the proposed facility needs to have the antennas

placed at a centerline of 50’ for the signal to reach the intended service area. The proposed

facility has been designed at its minimum functional height and the suggestions of the neighbors

and Planning Commissioners for previous CUP3572 / IS7275 were taken into account when

locating, designing, and siting this propsoed facility.

Please see Photo Simulations for additional details.

SITE SELECTION CRITERIA & NEED FOR FACILITY

The FCC’s Connect America Fund (CAF II) created census data maps identifying underserved

areas without high-speed internet services. AT&T’s engineers then generate search rings based

on locations that maximizes the number of living units served by the new facility. Maximizing

service of living units is a condition of the FCC’s CAF II grant, giving AT&T less flexibility in

selecting a tower location than AT&T would otherwise have in building out their cellular

network.

AT&T’s engineer began the site selection process by identifying a search area, called a “Search

Ring.” For this particular ring, the original search ring centered on residential homes in

unincorporated Prather. The Fresno County Planning Commission denied the facility within that

original search ring.

Page 16: STEVEN E. WHITE, DIRECTOR

Project Support Statement – CVL03147 Marshall Junction

Site Address: No Site Address, Prather, CA 93656 (APN: 138-070-66 & 138-070-69)

5

AT&T has issued three (3) different targeted search areas to try and cover the underserved

community of rural residences north of Millerton Road. The first search ring was issued in 2016

and was submitted as part of CUP3572 / IS7275. That project, proposed on a previous location at

15899 Garlock Lane (APN: 138-371-45), was denied by the Planning Commission on December

14, 2017 and AT&T chose not to pursue an appeal of that denial.

AT&T instead sought to find an alternative location that may provide the same service objectives

targeted by the first location on Garlock Lane. In order to move away from the existing rural

residences in the first search ring, AT&T looked to properties on higher elevations to try achieve

the height. The second search ring was centered around a very steep hill, triangulated by

Tollhouse Road, Millerton Road, and Nicholas Road. However, upon on-site visits to the

properties, the grade of the hill is in excess of 20% and AT&T’s construction teams determined

that construction of an access road would not be possible. Additionally, Fresno County also

discourages develop on slopes in excess of 20% grade.

The third and final search ring was issued in May 2018 and three (3) very small hilltops were

identified as possible feasible locations. There were only six (6) parcels and four (4) property

owners in the identified areas. The most optimal location was the proposed hill south of

Millerton Road, which was pursued as the only candidate.

Progression of Search Rings

The search ring represents the area within which a facility can be located to produce the desired

coverage objective. The centerline height of 50’ (with a total faux-tree height of 61’) represents

the required height of the antennas to produce the desired coverage objective. After evaluating

the County’s zoning regulations, the next step is to identify any existing towers within the search

ring that could allow for collocation. In this case, AT&T determined that there are no existing

structures within a 4-mile area which could meet its coverage needs.

Page 17: STEVEN E. WHITE, DIRECTOR

Project Support Statement – CVL03147 Marshall Junction

Site Address: No Site Address, Prather, CA 93656 (APN: 138-070-66 & 138-070-69)

6

NEARBY TOWERS AND WIRELESS FACILITIES

There are 3 wireless towers within a 5-mile vicinity of the proposed facility; however, none

would be able to provide the broadband internet and wireless service required.

Google Earth Overview

Tower 1

The KFPX FM radio station tower is over 100’ tall and is located over 3 miles away. It is too far

from the target service area. It would not be able to provide the objectives needed by AT&T’s

RAN engineer.

Tower 2

There is a telecommunications antenna(s) on a utility pole, less than 40’ in height, over 5 miles

from the facility. That candidate is too short and too far away. It would not be able to provide the

objectives needed by AT&T’s RAN engineer.

Tower 3

There is a 160’ tall tower located over 5 miles from the proposed facility. The facility is too far

away and would not be able to provide the objectives needed by AT&T’s RAN engineer.

Due to the above reasons, there are no collocation opportunities in this area.

Tower 1

Utility Pole (Tower 2)

Tower 3

Page 18: STEVEN E. WHITE, DIRECTOR

Project Support Statement – CVL03147 Marshall Junction

Site Address: No Site Address, Prather, CA 93656 (APN: 138-070-66 & 138-070-69)

7

COMPLIANCE WITH FRESNO COUNTY WIRELESS COMMUNICATION GUIDELINES Fresno County has specific telecommunications guidelines for rural agricultural areas and

AT&T’s facilities complies with all requirements.

a. Tower sites should be selected to minimize disruption to agricultural aircraft operations,

farm irrigation systems, and movement of farm equipment. Applicants should describe

factors specific to the property that have been addressed in the site selection. If site

selection negotiation is conducted with an absentee owner, a supporting statement from

the farm manager should be provided.

Due to the difficulties at the previous location (CUP3572 / IS7275), AT&T narrowed down 3

key areas of higher elevation in sparsely populated areas to try and provide internet and wireless

services to the living units identified by the FCC. That Search Ring is provided above.

Furthermore, the facility was proposed in an area, sparsely populated, and without agricultural

aircraft oeprations.

b. Tower sites should be selected to minimize disruption to agricultural aircraft operations,

farm irrigation systems, and movement of farm equipment. Applicants should describe

factors specific to the property that have been addressed in the site selection. If site

selection negotiation is conducted with an absentee owner, a supporting statement from

the farm manager should be provided.

The proposed facility is sited in an area without agricultural aircraft operations.

The nearest airport to the proposed facility is the Topham Ranch-Auberry Airport, which is

approximately 8.5 miles north. Additionally, the Kindsvater Ranch Airport is located

approximately 9 miles to the southeast

c. Generally, guyed towers should not be allowed, except for Broadcast T.V., Broadcast

Radio, and Amateur Radio.

N/A.

d. Towers should be sited to minimize aesthetic impacts to adjacent homesites on

surrounding properties.

Utilizing natural elevation, the chosen parcel is a tall hillside with existing trees and has been

reduced in overall height to 61’. Additionally, the facility has been stealthed as a faux-broadleaf

tree. Lastly, the land is undeveloped and used for cattle grazing. There will be no interference to

operations in the vicinity.

e. Towers should be sited to minimize impacts to adjacent farming operations on

surrounding properties.

The proposed facility is sited in an area without adjacent farming operations. The properties are

zoned agricultural, but are used for single-family residences on large lots or are

undeveloped/vacant.

Page 19: STEVEN E. WHITE, DIRECTOR

Project Support Statement – CVL03147 Marshall Junction

Site Address: No Site Address, Prather, CA 93656 (APN: 138-070-66 & 138-070-69)

8

COVERAGE AREA The proposed facility, located on the Smith Foothill Ranch property, was chosen by AT&T’s

engineer as the best candidate in the search ring for achieving AT&T’s coverage objectives.

Existing Coverage

Proposed Coverage

SAFETY BENEFITS OF IMPROVED WIRELESS SERVICE

Mobile phone use has become an extremely important system for public safety. Motorists with

disabled vehicles (or worse) can use their phone to call in and request appropriate assistance.

With strong cellular coverage along important roadways, emergency response is just a phone call

away. Furthermore, as a back-up system to traditional landline phone service, mobile phones

have proven to be extremely important during natural disasters and other catastrophes.

Page 20: STEVEN E. WHITE, DIRECTOR

Project Support Statement – CVL03147 Marshall Junction

Site Address: No Site Address, Prather, CA 93656 (APN: 138-070-66 & 138-070-69)

9

TECHNOLOGY & CONSUMER SERVICES THE CARRIER WILL PROVIDE ITS

CUSTORMERS

AT&T offers its customers multiple services such as, voice calls, text messaging, mobile email,

picture/video messaging, mobile web, navigation, broadband access, V CAST, and E911

services. Wireless service enhances public safety and emergency communications in the

community.

LIGHTING

Unless tower lighting is required by the FAA the only lighting on the facility will be a shielded

motion sensor light by the door on the equipment shelter.

NOISE The standby generator will be operated for approximately15-30 minutes per week for

maintenance purposes, and during power outages and disasters. Testing and maintenance will

take place weekdays between 8:00 a.m. and 7:00 p.m.

During construction of the facility, which typically lasts around two months, acceptable noise

levels will not be exceeded.

HAZARDOUS MATERIALS A Hazardous Material Business Plan will also be submitted upon project completion, and stored

on site after construction.

SITE MAINTENANCE

A technician will visit the site approximately twice a month to check the facility and perform any

necessary maintenance.

STATEMENT OF COMMITMENT TO ALLOW COLLOCATION The proposed facility has been designed in a manner that will structurally accommodate

additional antennas and future collocation. AT&T welcomes other carriers to collocate on their

facilities whenever possible.

COMPLIANCE WITH FCC STANDARDS

This project will not interfere with any TV, radio, telephone, satellite, or any other signals. Any

interference would be against the Federal Law and would be a violation AT&T’s FCC License.

CONSTRUCTION SCHEDULE

The construction of the facility will be in compliance with all local rules and regulations. The

typical duration is two months. The crew size will range from two to ten individuals.

NOTICE OF ACTIONS AFFECTING THIS DEVELOPMENT PERMIT

In accordance with California Government Code Section 65945(a), AT&T requests notice of any

proposal to adopt or amend the: general plan, specific plan, zoning ordinance, ordinance(s)

affecting building or grading permits that would in any manner affect this development permit.

Any such notice may be sent to 2009 V Street, Sacramento, CA 95818.

Page 21: STEVEN E. WHITE, DIRECTOR

CVL03147 Marshall Junction {Smith Family Ranch LLC)

Federal Communications Commission - Local and State Government Advisory Committee

(June 2000)

A Local Government Official's Guide to Transmitting Antenna RF Emission Safety: Rules, Procedures, and Practical Guidance

Over the past two years, the Federal Communications Commission (FCC) and its Local and State Government Advisory Committee (LSGAC) have been working together to prepare a voluntary guide to assist state and local governments in devising efficient procedures for ensuring that the antenna facilities located in their communities comply with the FCC's limits for human exposure to radiofrequency (RF) electromagnetic fields. The attached guide is the product of this joint effort.

We encourage state and local government officials to consult this guide when addressing issues of facilities siting within their communities. This guide contains basic information, in a fonn accessible to officials and citizens alike, that will alleviate misunderstandings in the complex area of RF emissions safety. This guide is not intended to replace OET Bulletin 65, which contains detailed technical information regarding RF issues, and should continue to be used and consulted for complex sites. The guide contains information, tables, and a model checklist to assist state and local officials in identifying sites that do not raise concerns regarding compliance with the Commission's RF exposure limits. In many cases, the model checklist offers a quick and effective way for state and local officials to establish that particular RF facilities are unlikely to exceed specific federal guidelines that protect the public from the environmental effects of RF emissions. Thus, we believe this guide will facilitate federal, state, and local governments working together to protect the public while bringing advanced and innovative communications services to consumers as rapidly as possible. We hope and expect that use of this guide will benefit state and local governments, service providers, and, most importantly, the American public.

We wish all of you good luck in your facilities siting endeavors.

William E. Kennard, Chaimmn Federal Communications Commission

Kenneth S. Fellman, Chair Local and State Government Advisory Committee

Page 22: STEVEN E. WHITE, DIRECTOR

Federal Communications Commission - Local and State Government Advisory Committee (June 2000)

A Local Government Official's Guide to Transmitting Antenna RF Emission Safety: Rules, Procedures, and Practical Guidance

APPENDIX A

Optional Checklist for Local Government To Determine Whether a Facility is Categorically Excluded

Purpose: The FCC has detennined that many wireless facilities are unlikely to cause human exposures in excess of RF exposure guidelines. Operators of those facilities are exempt from routinely having to determine their compliance. These facilities are termed "categorically excluded." Section 1. l 307(b )( l) of the Commission's rules defines those categorically excluded facilities. This checklist will assist state and local government agencies in identifying those wireless facilities that are categorically excluded, and thus are highly unlikely to cause exposure in excess of the FCC's guidelines. Provision of the information identified on this checklist may also assist FCC staff in evaluating any inquiry regarding a facility's compliance with the RF exposure guidelines.

BACKGROUND INFORMATION

1. Facility Operator's Legal Name: _A_T_&_T_M_o_b_i_li..._ty_. _____________ _ 2. Facility Operator's Mailing Address: 5001 Executive Pkwy, 4W850T, San Ramon, CA 94583 3. Facility Operator's Contact Name/Title: _C_a_~e_.y'--C_h_a1_1 ____________ _

4. Facility Operator's Office Telephotte: _E_m_a_11_-_k_c_l_12_8_@~at_t._c_om _________ _

5. Facility Operator's Fax:------------------------6. Facility Name: CVL03147 Marshall Junction 7. Facility Address: No Site Address, Prather, CA 93656

8. Facility City/Community: _....;:M;.;.;;;..o..oa=rs=h=al=l...;;.J-=un=c'""t=io=n'-----------------9. Facility State and Zip Code,___: _C_A~,_9_3_65_6 ________________ _ 10. Latitude: N 36.971133 (NAD 83) 11.

continue

Page 23: STEVEN E. WHITE, DIRECTOR

Optional Local Government Checklist (page 2)

EVALUATION OF CATEGORICAL EXCLUSION

12. Licensed Radio Service (see attached Table 1): PCS 26 . 13. Structure Type (free-standing or building/roof-mounted): Freestan~mg. 14. Antenna Type [omnidirectional or directional (includes sectored)]: Directional 15. Height above ground of the lowest point of the antenna (in feet): 46' at bottom of antennas 16. IZl Check if all of the following are true: ( 57' to top of steel, 61' to top of

(a) This facility will be operated in the Multipoint Distribution Service, Paging and Radiotelephone Service, Cellular Radiotelephone Service, Narrowband or Broadband Personal Communications Service, Private Land Mobile Radio Services Paging Operations, Private Land Mobile Radio Service Specialized Mobile Radio, Local Multipoint Distribution Service, or service regulated under Part 74, Subpart I (see question 12).

(b) This facility will not be mounted on a building (see question 13). (c) The lowest point of the antenna will be at least 32.8 feet (10 meters) above the ground (see

question 15).

IIfbox 16 is checked, this facility is categorically excluded and is unlikely to cause exposure in !excess of the FCC's guidelines. The remainder of the checklist need not be completed. If box 16 is jnot checked, continue to question 17.

I ! 17. Enter the power threshold for categorical exclusion for this service from the attached Table 1 in j watts ERP or EIRP* (note: EIRP = (1.64) X ERP): 118. Enter the total number of channels if this will be an omnidirectional antenna, or the maximum I number of channels in any sector if this will be a sectored antem1a: 119. Enter the ERP or EIRP per channel (using the same units as in question 17)_· ------120. Multiply answer 18 by answer 19_· ---------------------1

j 21. Is the answer to question 20 less than or equal to the value from question 17 (yes or no)?

!If the answer to question 21 is YES, this facility is categorically excluded. It is unlikely to cause I exposure in excess of the FCC's guidelines.

!If the answer to question 21 is NO, this facility is not categorically excluded. Further investigation

'

may be appropriate to verify whether the facility may cause exposure in excess of the FCC's ,guidelines. I I

L--··-------····-------··----·----------·--···--·------······---·---·--------------··-·---···-·---·-····-··---·-------·---··---·------·-·-··---·-····--······--------·--·---···-·--····--·---·-----------··------·--J

*"ERP" means "effective radiated power" and "EIRP" means "effective isotropic radiated power

Page 24: STEVEN E. WHITE, DIRECTOR

TABLE 1: TRANSMITTERS, F AClLITIES AND OPERATIONS SUBJECT TO ROUTINE ENVIRONMENTAL EVALUATION

SERVICE (TITLE 47 CFR RULE PART) EVALUATION REQUIRED IF:

Experimental Radio Services power > 100 W ERP (164 W EIRP) (part 5)

Multipoint Distribution Service non-building-mounted antennas: height above ( subpait K of part 21) · ground level to lowest point of antenna < 10

m and power > 1640 W EIRP building-mounted antennas: power > 1640 W EIRP

Paging and Radiotelephone Service non-building-mounted antennas: height above (subpart E of part 22) ground level to lowest point of antenna < 10

m and power> 1000 W ERP (1640 W EIRP) building-mounted antennas: power > 1000 W ERP ( 1640 W EIRP)

Cellular Radiotelephone Service non-building-mounted antennas: height above (subpart Hof part 22) ground level to lowest point of antenna < 10

m and total power of all channels > 1000 W ERP ( 1640 W EIRP) building-mounted antennas: total power of all channels > 1000 W ERP (1640 W EIRP)

Page 25: STEVEN E. WHITE, DIRECTOR

TABLE 1 (cont.)

SERVICE (TITLE 47 CFR RULE PART) EVALUATION REQUIRED IF:

Personal Communications Services (1) Na1rnwband PCS (subpart D): (part 24) non-building-mounted antennas: height

above ground level to lowest point of antenna < 10 m and total power of all channels > 1000 W ERP (1640 W EIRP) building-mounted antennas: total power of all channels > 1000 W ERP ( 1640 W EIRP)

(2) Broadband PCS (subpart E): non-building-mounted antennas: height above ground level to lowest point of antenna < 10 m and total power of all channels > 2000 W ERP (3280 W EIRP) building-mounted antennas: total power of all channels > 2000 W ERP (3280 W EIRP)

Satellite Communications all included (part 25)

General Wireless Communications Service total power of all channels > 1640 W EIRP (part 26)

Wireless Communications Service total power of all channels > 1640 W EIRP (part 27)

Radio Broadcast Services all included (part 73)

Page 26: STEVEN E. WHITE, DIRECTOR

TABLE 1 (cont.)

SERVICE (TITLE 47 CFRRULEPART) EVALUATION REQUIRED IF:

Experimental, auxiliary, and special subparts A, G, L: power> 100 W ERP broadcast and other program

distributional services subpart I: (part 74) non-building-mounted antennas: height above

ground level to lowest point of antenna < I 0 m and power > 1640 W EIRP building-mounted antennas: power > 1640 W EIRP

Stations in the Maritime Services ship earth stations only (part 80)

Private Land Mobile Radio Services non-building-mounted antennas: height above Paging Operations ground level to lowest point of antenna < 10

(part 90) m and power> 1000 W ERP (1640 W EIRP) building-mounted antemrns: power > 1000 W ERP ( 1640 W EIRP)

Private Land Mobile Radio Services non-building-mounted antennas: height above Specialized Mobile Radio ground level to lowest point of antenna < 10

(part 90) m and total power of all channels > 1000 W ERP ( 1640 W EIRP) building-mounted antennas: total power of all channels > 1000 W ERP ( 1640 W EIRP)

Page 27: STEVEN E. WHITE, DIRECTOR

TABLE 1 (cont.)

SERVICE (TITLE 47 CFR RULE PART) EVALUATION REQUIRED IF:

Amateur Radio Service transmitter output power> levels specified in (part 97) § 97.13(c)(l) of this chapter

Local Multipoint Distribution Service non-building-mounted antennas: height above (subpart L of part 101) ground level to lowest point of antenna < l 0

m and power> 1640 W EIRP building-mounted antennas: power> 1640 W EIRP

LMDS licensees are required to attach a label to subscriber transceiver antennas that: (1) provides adequate notice regarding potential radiofrequency safety hazards, e.g., information regarding the safe minimum separation distance required between users and transceiver antennas; and (2) references the applicable FCC-adopted limits for radiofrequency exposure specified in § 1.1310 of this chapter.

-end-telecom _site_ checklistl .doc

Page 28: STEVEN E. WHITE, DIRECTOR

SHEET INDEX PROJECT INFORMATION

APPROVALSAPPROVED BY: INITIALS: DATE:

VENDOR:

LEASING / LANDLORD:

R.F.:

ZONING:

CONSTRUCTION:

POWER / TELCO:

PG&E:

CODE COMPLIANCE

PROJECT DESCRIPTION PROJECT TEAM

GENERAL CONTRACTOR NOTES

DO NOT SCALE DRAWINGSTHESE DRAWINGS ARE FORMATTED TO BE FULL SIZE AT 24" x 36". CONTRACTORSHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ONTHE JOBSITE AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT/ENGINEER INWRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK ORMATERIAL ORDERS OR BE RESPONSIBLE FOR THE SAME.

DIRECTIONS FROM AT&T

PROPERTY INFORMATION:SITE NAME: MARSHALL JUNCTION

SITE NUMBER: CVL03147

SITE ADDRESS: MILLERTON ROADPRATHER, CA 93656

A.P.N. NUMBER: 138-070-66 (TOWER)138-070-69 (GROUND EQUIPMENT)

CURRENT ZONING: AE40 (EXCLUSIVE AGRICULTURE -40 ACRE)

JURISDICTION: COUNTY OF FRESNO

DIRECTIONS FROM AT&T's OFFICE AT 2600 CAMINO RAMON, SAN RAMON, CA:

HANDICAP REQUIREMENTSFACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION, ACCESSIBILITYACCESS AND REQUIREMENTS ARE NOT REQUIRED, IN ACCORDANCE WITHCALIFORNIA STATE ADMINISTRATIVE CODE, PART 2, TITLE 24, SECTION 1103B.1,EXCEPTION 1 & SECTION 1134B.2.1, EXCEPTION 4.

OCCUPANCY AND CONSTRUCTION TYPE

1. HEAD EAST2. TURN RIGHT TOWARD CAMINO RAMON3. TURN RIGHT ONTO CAMINO RAMON4. TURN RIGHT ONTO BOLLINGER CANYON ROAD5. MERGE ONTO I-680 S VIA THE RAMP TO SAN JOSE6. TAKE EXIT 30A TO MERGE ONTO I-580 E TOWARD STOCKTON7. KEEP LEFT TO CONTINUE ON I-205 E, FOLLOW SIGNS FOR INTERSTATE 205/TRACY/STOCKTON8. MERGE ONTO I-5 N9. TAKE EXIT 461 FOR CA-120 TOWARD MANTECA/SONORA10. CONTINUE ONTO CA-120 E11. TAKE EXIT 6 TO MERGE ONTO CA-99 S TOWARD MODESTO/FRESNO12. TAKE EXIT 155 FOR CLEVELAND AVENUE13. TURN LEFT ONTO AVENUE 15 1/2/WEST CLEVELAND AVENUE (SIGNS FOR MILLERTON LAKE)14. CONTINUE TO FOLLOW WEST CLEVELAND AVENUE15. TURN RIGHT TO STAY ON WEST CLEVELAND AVENUE16. TURN SLIGHTLY LEFT ONTO AVENUE 15 1/2/WEST CLEVELAND AVENUE17. CONTINUE TO FOLLOW W CLEVELAND AVENUE18. CONTINUE ONTO TOZER STREET19. TURN LEFT ONTO CA-145 N/E YOSEMITE AVENUE20. CONTINUE TO FOLLOW CA-145 N21. TURN RIGHT ONTO ROAD 20622. CONTINUE ONTO NORTH FORK ROAD23. TURN LEFT ONTO MILLERTON ROAD24. TURN LEFT ONTO AUBERRY ROAD25. TURN RIGHT ONTO MILLERTON ROAD

YOUR DESTINATION IS ON THE RIGHT

AT&T:

VICINITY MAP

REVPROPERTY OWNER:SMITH FOOTHILL RANCH, LLC.8703 NORTH DEL MAR AVENUEFRESNO, CA 93711

OCCUPANCY : S-2 (UNMANNED TELECOMMUNICATIONS FACILITY), U (TOWER)

CONSTRUCTION TYPE: V-B

T-1 TITLE SHEET #GN-1 GENERAL NOTES & ABBREVIATIONS #C-1 SURVEY SHEET #A-1.0 UTILITY SITE PLAN #A-1.1 OVERALL AND ENLARGED SITE PLANS #A-2.1 EQUIPMENT LAYOUT PLAN #A-2.2 MONO-BROADLEAF EQUIPMENT LAYOUT PLAN #A-3.1 ANTENNA LAYOUT PLAN & SCHEDULE #A-3.2 ANTENNA DETAILS #A-4.1 PROPOSED ELEVATIONS #A-4.2 PROPOSED ELEVATIONS #

ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCEWITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCALGOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMITWORK NOT CONFORMING TO THESE CODES.

1. 2016 CALIFORNIA ADMINISTRATIVE CODE, CHAPTER 10, PART 1, TITLE 24 CODE OFREGULATIONS

2. 2016 CALIFORNIA BUILDING CODE (CBC) WITH CALIFORNIA AMENDMENTS,BASED ON THE 2012 IBC (PART 2, VOL 1-2)

3. 2016 CALIFORNIA RESIDENTIAL CODE (CRC) WITH APPENDIX H, PATIO COVERS,BASED ON THE 2012 IRC (PART 2.5)

4. 2016 CALIFORNIA GREEN BUILDINGS STANDARDS CODE (CALGREEN) (PART 11)(AFFECTED ENERGY PROVISIONS ONLY)

5. 2016 CALIFORNIA FIRE CODE (CFC), BASED ON THE 2012 IFC, WITH CALIFORNIAAMENDMENTS (PART 9)

6. 2016 CALIFORNIA MECHANICAL CODE (CMC), BASED ON THE 2012 UMC (PART 4)

7. 2016 CALIFORNIA PLUMBING CODE (CPC), BASED ON THE 2012 UPC (PART 5)

8. 2016 CALIFORNIA ELECTRICAL CODE (CEC) WITH CALIFORNIA AMENDMENTS,BASED ON THE 2011 NEC (PART 3)

9. 2016 CALIFORNIA ENERGY CODE (CEC)

10. ANSI / EIA-TIA-222-G

11. 2015 NFPA 101, LIFE SAFETY CODE

12. 2016 NFPA 72, NATIONAL FIRE ALARM CODE

13. 2016 NFPA 13, FIRE SPRINKLER CODE

NEW SITE BUILD UNMANNED TELECOMMUNICATIONS FACILITY.

1. BRING POWER / TELCO / FIBER TO SITE LOCATION

2. INSTALL AT&T APPROVED PRE-MANUFACTURED EQUIPMENT SHELTER &ASSOCIATED INTERIOR EQUIPMENT

3. INSTALL AT&T MONOPOLE WITH ANTENNAS & ASSOCIATED TOWERMOUNTED EQUIPMENT

4. INSTALL GENERATOR WITH FUEL TANK

APPLICANT / LESSEE:AT&T2600 CAMINO RAMON, 4W850 NSAN RAMON, CA 94583

ARCHITECT / ENGINEER:MST ARCHITECTS INC.1520 RIVER PARK DRIVESACRAMENTO, CA 95815CONTACT: MANUEL S. TSIHLASEMAIL: [email protected]: (916) 567-9630

FA CODE: 13787646

RF ENGINEER:AT&T5555 EAST OLIVE AVENUEFRESNO, CA 93727CONTACT: JAKE BALUYUTEMAIL: [email protected]: (559) 454-5694

USID: 217128

PROJECT SITE

ZONING MANAGER:COMPLETE WIRELESS CONSULTING, INC.2009 V STREETSACRAMENTO, CA 95818CONTACT: MARIA KIMEMAIL: [email protected]: (916) 247-6087

MILLERTON ROAD

AUBER

RY R

OAD

MILLERTON ROAD

AUBERRY ROAD

MO

RGA

N C

AN

YON

RO

AD

MILLERTON ROAD

CONSTRUCTION MANGER:ERICSSON6140 STONERIDGE MALL ROAD, #350PLEASANTON, CA 94588CONTACT: BRIAN FESLEREMAIL: [email protected]: (530) 682-8862

LEASING MANAGER:COMPLETE WIRELESS CONSULTING, INC.2009 V STREETSACRAMENTO, CA 95818CONTACT: MARIA KIMEMAIL: [email protected]: (916) 247-6087

SITE NUMBER: CVL03147

SITE NAME: MARSHALL JUNCTION

MILLERTON ROAD

PRATHER, CA 93656

JURISDICTION: FRESNO COUNTY

APN: 138-070-66 (TOWER)APN: 138-070-69 (GROUND EQUIPMENT)

TITLE SHEET

T-1

PREPARED FOR

REV DESCRIPTIONDATE

SHEET TITLE:

SHEET NUMBER:

CHECKED BY:

DRAWN BY:

PROJECT NO:

IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE

DIRECTION OF A LICENSED PROFESSIONALENGINEER, TO ALTER THIS DOCUMENT.

Vendor:

Licensee:

Architect:

AT&T SITE NO:

162.2380

CVL03147

1520 River Park DriveSacramento, California 95815

12/07/18 90% ZD

2600 Camino RamonSan Ramon, California 94583

Issued For:

CVL03147MARSHALLJUNCTION

MILLERTON ROADPRATHER, CA 93656

MWS

TST

01/08/19 100% ZD

Page 29: STEVEN E. WHITE, DIRECTOR

PLANS ARE INTENDED TO BE DIAGRAMMATIC OUTLINE ONLY, UNLESS NOTED OTHERWISE. THE WORK SHALL INCLUDE FURNISHING MATERIALS,EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS.

1.

THE CONTRACTOR SHALL OBTAIN, IN WRITING, AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEM NOT CLEARLY DEFINEDOR IDENTIFIED BY THE CONTRACT DOCUMENTS.

2.

CONTRACTOR SHALL CONTACT USA (UNDERGROUND SERVICE ALERT) AT (800) 227-2600, FOR UTILITY LOCATIONS, 48 HOURS BEFOREPROCEEDING WITH ANY EXCAVATION, SITE WORK OR CONSTRUCTION.

3.

THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESSSPECIFICALLY INDICATED OTHERWISE, OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE.

4.

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CBC / UBC'S REQUIREMENTS REGARDING EARTHQUAKE RESISTANCE, FOR, BUTNOT LIMITED TO, PIPING, LIGHT FIXTURES, CEILING GRID, INTERIOR PARTITIONS, AND MECHANICAL EQUIPMENT. ALL WORK MUST COMPLYWITH LOCAL EARTHQUAKE CODES AND REGULATIONS.

5.

REPRESENTATIONS OF TRUE NORTH, OTHER THAN THOSE FOUND ON THE PLOT OF SURVEY DRAWINGS, SHALL NOT BE USED TO IDENTIFY ORESTABLISH BEARING OF TRUE NORTH AT THE SITE. THE CONTRACTOR SHALL RELY SOLELY ON THE PLOT OF SURVEY DRAWING AND ANYSURVEYOR'S MARKINGS AT THE SITE FOR THE ESTABLISHMENT OF TRUE NORTH, AND SHALL NOTIFY THE ARCHITECT / ENGINEER PRIOR TOPROCEEDING WITH THE WORK IF ANY DISCREPANCY IS FOUND BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND THETRUE NORTH ORIENTATION AS DEPICTED ON THE CIVIL SURVEY. THE CONTRACTOR SHALL ASSUME SOLE LIABILITY FOR ANY FAILURE TO NOTIFYTHE ARCHITECT / ENGINEER.

6.

THE BUILDING DEPARTMENT ISSUING THE PERMITS SHALL BE NOTIFIED AT LEAST TWO WORKING DAYS PRIOR TO THE COMMENCEMENT OFWORK, OR AS OTHERWISE STIPULATED BY THE CODE ENFORCEMENT OFFICIAL HAVING JURISDICTION.

7.

DO NOT EXCAVATE OR DISTURB BEYOND THE PROPERTY LINES OR LEASE LINES, UNLESS OTHERWISE NOTED.8.

ALL EXISTING UTILITIES, FACILITIES, CONDITIONS, AND THEIR DIMENSIONS SHOWN ON THE PLAN HAVE BEEN PLOTTED FROM AVAILABLERECORDS. THE ARCHITECT / ENGINEER AND THE OWNER ASSUME NO RESPONSIBILITY WHATSOEVER AS TO THE SUFFICIENCY OR THEACCURACY OF THE INFORMATION SHOWN ON THE PLANS, OR THE MANNER OF THEIR REMOVAL OR ADJUSTMENT. CONTRACTORS SHALL BERESPONSIBLE FOR DETERMINING EXACT LOCATION OF ALL EXISTING UTILITIES AND FACILITIES PRIOR TO START OF CONSTRUCTION.CONTRACTORS SHALL ALSO OBTAIN FROM EACH UTILITY COMPANY DETAILED INFORMATION RELATIVE TO WORKING SCHEDULES ANDMETHODS OF REMOVING OR ADJUSTING EXISTING UTILITIES.

9.

CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES, BOTH HORIZONTAL AND VERTICALLY, PRIOR TO THE START OF CONSTRUCTION. ANYDISCREPANCIES OR DOUBTS AS TO THE INTERPRETATION OF PLANS SHOULD BE IMMEDIATELY REPORTED TO THE ARCHITECT / ENGINEER FORRESOLUTION AND INSTRUCTION, AND NO FURTHER WORK SHALL BE PERFORMED UNTIL THE DISCREPANCY IS CHECKED AND CORRECTED BYTHE ARCHITECT / ENGINEER. FAILURE TO SECURE SUCH INSTRUCTION MEANS CONTRACTOR WILL HAVE WORKED AT HIS/HER OWN RISK ANDEXPENSE.

10.

ALL NEW AND EXISTING UTILITY STRUCTURES ON SITE AND IN AREAS TO BE DISTURBED BY CONSTRUCTION SHALL BE ADJUSTED TO FINISHELEVATIONS PRIOR TO FINAL INSPECTION OF WORK.

11.

ANY DRAIN AND/OR FIELD TILE ENCOUNTERED / DISTURBED DURING CONSTRUCTION SHALL BE RETURNED TO IT'S ORIGINAL CONDITIONPRIOR TO COMPLETION OF WORK. SIZE, LOCATION AND TYPE OF ANY UNDERGROUND UTILITIES OR IMPROVEMENTS SHALL BE ACCURATELYNOTED AND PLACED ON "AS-BUILT" DRAWINGS BY GENERAL CONTRACTOR, AND ISSUED TO THE ARCHITECT / ENGINEER AT COMPLETIONOF PROJECT.

12.

ALL TEMPORARY EXCAVATIONS FOR THE INSTALLATION OF FOUNDATIONS, UTILITIES, ETC., SHALL BE PROPERLY LAID BACK OR BRACED INACCORDANCE WITH CORRECT OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) REQUIREMENTS.

13.

INCLUDE MISC. ITEMS PER AT&T SPECIFICATIONS14.

SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES AS ADOPTED BY THE LOCALAUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION.

THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF CONTRACT AWARD SHALL GOVERN THE DESIGN.

SUBCONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING STANDARDS:

- AMERICAN CONCRETE INSTITUTE (ACI) 318, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE- AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF STEEL CONSTRUCTION, ASD, NINTH EDITION- TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA) 222-G, STRUCTURAL STANDARD FOR STRUCTURAL ANTENNA TOWER AND ANTENNASUPPORTING STRUCTURES- INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 81, GUIDE FOR MEASURING EARTH RESISTIVITY, GROUND IMPEDANCE, ANDEARTH SURFACE POTENTIALS OF A GROUND SYSTEM IEEE 1100 (1999) RECOMMENDED PRACTICE FOR POWERING AND GROUNDING OFELECTRICAL EQUIPMENT.-IEEE C62.41, RECOMMENDED PRACTICES ON SURGE VOLTAGES IN LOW VOLTAGE AC POWER CIRCUITS (FOR LOCATION CATEGORY "C3"AND "HIGH SYSTEM EXPOSURE")

TIA 607 COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FOR TELECOMMUNICATIONS TELCORDIA GR-63 NETWORKEQUIPMENT-BUILDING SYSTEM (NEBS): PHYSICAL PROTECTIONTELCORDIA GR-347 CENTRAL OFFICE POWER WIRINGTELCORDIA GR-1275 GENERAL INSTALLATION REQUIREMENTSTELCORDIA GR-1503 COAXIAL CABLE CONNECTIONS

ANY AND ALL OTHER LOCAL & STATE LAWS AND REGULATIONS

FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING MATERIAL, METHODS OF CONSTRUCTION, OROTHER REQUIREMENTS, THE MOST RESTRICTIVE SHALL GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT AND ASPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL GOVERN.

GENERAL CONSTRUCTION NOTES:

APPLICABLE CODES, REGULATIONS AND STANDARDS:

ABBREVIATIONS

SYMBOLS LEGEND

OFFICE101 ROOM NUMBER

WALL TYPE MARK

KEYNOTE,CONSTRUCTION ITEM

KEYNOTE,DIMENSION ITEM

ROOM NAME

WALL SECTION

DETAIL

3

BLDG. SECTIONA-3001

A-500D5

A-310A5

A-113C1

A-113C4

A-113A1

A-113A4 ELEVATION

3

2

CENTERLINE

ELEVATION DATUM

TILT-UP PANEL MARK

WINDOW SYMBOL

DOOR SYMBOL

PROPERTY LINE

3

±0"

001

10

A GRID/COLUMN LINE

A-3001

A.B. ANCHOR BOLTABV. ABOVEACCA ANTENNA CABLE COVER ASSEMBLYADD'L ADDITIONALA.F.F. ABOVE FINISHED FLOORA.F.G. ABOVE FINISHED GRADEALUM. ALUMINUMALT. ALTERNATEANT. ANTENNAAPPRX. APPROXIMATE(LY)ARCH. ARCHITECT(URAL)AWG. AMERICAN WIRE GAUGEBLDG. BUILDINGBLK. BLOCKBLKG. BLOCKINGBM. BEAMB.N. BOUNDARY NAILINGBTCW. BARE TINNED COPPER WIREB.O.F. BOTTOM OF FOOTINGB/U BACK-UP CABINETCAB. CABINETCANT. CANTILEVER(ED)C.I.P. CAST IN PLACECLG. CEILINGCLR. CLEARCOL. COLUMNCONC. CONCRETECONN. CONNECTION(OR)CONST. CONSTRUCTIONCONT. CONTINUOUSd PENNY (NAILS)DBL. DOUBLEDEPT. DEPARTMENTD.F. DOUGLAS FIRDIA. DIAMETERDIAG. DIAGONALDIM. DIMENSIONDWG. DRAWING(S)DWL. DOWEL(S)EA. EACHEL. ELEVATIONELEC. ELECTRICALELEV. ELEVATOREMT. ELECTRICAL METALLIC TUBINGE.N. EDGE NAILENG. ENGINEEREQ. EQUALEXP. EXPANSIONEXST.(E) EXISTINGEXT. EXTERIORFAB. FABRICATION(OR)F.F. FINISH FLOORF.G. FINISH GRADEFIN. FINISH(ED)FLR. FLOORFDN. FOUNDATIONF.O.C. FACE OF CONCRETEF.O.M. FACE OF MASONRYF.O.S. FACE OF STUDF.O.W. FACE OF WALLF.S. FINISH SURFACEFT.( ' ) FOOT (FEET)FTG. FOOTINGG. GROWTH (CABINET)GA. GAUGEGI. GALVANIZE(D)G.F.I. GROUND FAULT CIRCUIT INTERRUPTERGLB. (GLU-LAM) GLUE LAMINATED BEAMGPS GLOBAL POSITIONING SYSTEMGRND. GROUNDHDR. HEADERHGR. HANGERHT. HEIGHTICGB. ISOLATED COPPER GROUND BUS

IN. ( " ) INCH(ES)INT. INTERIORLB.(#) POUND(S)L.B. LAG BOLTSL.F. LINEAR FEET (FOOT)L. LONG(ITUDINAL)MAS. MASONRYMAX. MAXIMUMM.B. MACHINE BOLTMECH. MECHANICALMFR. MANUFACTURERMIN. MINIMUMMISC. MISCELLANEOUSMTL. METAL(N) NEWNO.(#) NUMBERN.T.S. NOT TO SCALEO.C. ON CENTEROPNG. OPENINGP/C PRECAST CONCRETEPCS PERSONAL COMMUNICATION SERVICESPLY. PLYWOODPPC POWER PROTECTION CABINETPRC PRIMARY RADIO CABINETP.S.F. POUNDS PER SQUARE FOOTP.S.I. POUNDS PER SQUARE INCHP.T. PRESSURE TREATEDPWR. POWER (CABINET)QTY. QUANTITYRAD.(R) RADIUSREF. REFERENCEREINF. REINFORCEMENT(ING)REQ'D/ REQUIREDRGS. RIGID GALVANIZED STEELSCH. SCHEDULESHT. SHEETSIM. SIMILARSPEC. SPECIFICATIONSSQ. SQUARES.S. STAINLESS STEELSTD. STANDARDSTL. STEELSTRUC. STRUCTURALTEMP. TEMPORARYTHK. THICK(NESS)T.N. TOE NAILT.O.A. TOP OF ANTENNAT.O.C. TOP OF CURBT.O.F. TOP OF FOUNDATIONT.O.P. TOP OF PLATE (PARAPET)T.O.S. TOP OF STEELT.O.W. TOP OF WALLTYP. TYPICALU.G. UNDER GROUNDU.L. UNDERWRITERS LABORATORYU.N.O. UNLESS NOTED OTHERWISEV.I.F. VERIFY IN FIELDW WIDE (WIDTH)w/ WITHWD. WOODW.P. WEATHERPROOFWT. WEIGHTC CENTERLINEP PLATE, PROPERTY LINE

GROUT OR PLASTER

(E) BRICK

(E) MASONRY

CONCRETE

EARTH

GRAVEL

PLYWOOD

SAND

PLYWOOD

SAND

(E) STEEL

MATCH LINE

GROUND CONDUCTOR

TELEPHONE CONDUIT

POWER CONDUIT

COAXIAL CABLE

CHAIN LINK FENCE

OVERHEAD SERVICE CONDUCTORSOH

LL

WOOD FENCE

(P) ANTENNA

(P) RRU

(P) DC SURGE SUPRESSION

(F) ANTENNA

(F) RRU

(E) EQUIPMENT

GENERAL NOTES& ABBREVIATIONS

GN-1

PREPARED FOR

REV DESCRIPTIONDATE

SHEET TITLE:

SHEET NUMBER:

CHECKED BY:

DRAWN BY:

PROJECT NO:

IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE

DIRECTION OF A LICENSED PROFESSIONALENGINEER, TO ALTER THIS DOCUMENT.

Vendor:

Licensee:

Architect:

AT&T SITE NO:

162.2380

CVL03147

1520 River Park DriveSacramento, California 95815

12/07/18 90% ZD

2600 Camino RamonSan Ramon, California 94583

Issued For:

CVL03147MARSHALLJUNCTION

MILLERTON ROADPRATHER, CA 93656

MWS

TST

01/08/19 100% ZD

Page 30: STEVEN E. WHITE, DIRECTOR

0

DATE OF SURVEY: 09-28-18

SURVEYED BY OR UNDER DIRECTION OF: KENNETH D. GEIL, RCE 14803

LOCATIED IN THE COUNTY OF FRESNO, STATIE OF CALIFORNIA

BEARINGS SHOWN ARE BASED UPON MONUMENTS FOUND AND RECORD INFORMATION. THIS IS NOT A BOUNDARY SURVEY.

ELEVATIONS SHOWN ON THIS PLAN ARE BASED UPON U.S.G.S. N.A.V.D. 88 DATUM. ABOVE MEAN SEA LEVEL UNLESS OTHERWISE NOTIED.

N.G.V.D. 1929 CORRECTION: SUBTIRACT 2.69' FROM ELEVATIONS SHOWN.

CONTOUR INTIERVAL: 1 FT.

ASSESSOR'S PARCEL NUMBERS: 138-070-66 (TOWER) 138-070-69 (EQUIPMENT)

LAND OWNER(S): SMITH FOOTHILL RANCH LLC 8703 N DEL MAR AVE FRESNO, CA 93711

' ' ' I ,' /

' ' ' ' '

SCALE 1" 20' 10 20 40 GO

--~-

'. \ ', ',

\ \ \ \ ', : I ,

\ \ '1 I I I I ,' ,1

'1 1 I I I I I I I

I 1 I I I I I I I

\ I I I I I I I I I I I I I I I I I

\ I I I I I I I I I I I I I I

I I I I I I

I I I I I I I I I

I \ 1 I \

i' / / ' ' '

' ' ' 1 1 I I /

I I I I

I I I I I I I I

' ' I I

I I I I I I I I

/ I

I , / , I I I / ; '

' ' '

I I I

I I

! ' I I i' I

'

' ! ' '

' i' i

Project Nome: CVL03147 Marshall Junction

Project Site Location: Millerton Rood Prather, CA 93656 Fresno County

Dote of Observation: 09-29-18

Equipment/Procedure Used to Obtain Coordinates: Trimble Pathfinder Geo XT post processed with Pathfinder Office software.

Type of Antenna Mount: Proposed Tree Pole Coordinates

Latitude: N 36"58'16.08" (NAD83) N 36"58'16.26" (NAD27) N 36. 971133" N 36. 971183"

Longitude: W 119'32'20.15" (NAD83) W 119'32'16.66" (NAD27) w 119.538931' w 119.537961'

ELEVATION of Ground at Structure (NAVD88) 916' AMSL

' ' I , ' ' ' ' \ '1

\ \ ' ' ' ' \ \ ' ' ' '

M.N.

A.PN 138-070-66

I I I I /

I I I /

' ' ' ' ' ' ' ' '

- - -

- -

I I

_L

-31 I

-33 I I

A.PN 138-070-66 I

-68 -52 APN 138-070-67

MILLERTON RD 60' R/W

I APN 138-070-69

I

I I APN 138-070-07

APN 138-070-65

-51

-71

-70

L _J SCALE 1" 1000'

THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATION AS INSTRUMENTS OF SERVICE, ARE THE EXCLUSIVE PROPERTY OF GEIL ENGINEERING AND THEIR USE AND PUBLICATION SHALL BE RESTRICTIED TO THE ORIGINAL SITIE AND CARRIER FOR WHICH THEY ARE PREPARED. REUSE, REPRODUCTION OR PUBLICATION BY ANY METHOD, IN WHOLE OR IN PART, IS PROHIBITIED EXCEPT BY WRITTIEN PERMISSION FROM GEIL ENGINEERING TITLE TO THESE PLANS AND/OR SPECIFICATIONS SHALL REMAIN WITH GEIL ENGINEERING WITHOUT PREJUDICE AND VISUAL CONTACT WITH THEM SHALL CONSTITUTE PRIMA FACIE EVIDENCE OF ACCEPTANCE OF THESE RESTIRICTIONS.

BOUNDARY SHOWN IS BASED ON MONUMENTATION FOUND AND RECORD INFORMATION. THIS IS NOT A BOUNDARY SURVEY. THIS IS A SPECIALIZED TOPOGRAPHIC MAP WITH PROPERTY LINES AND EASEMENTS BEING A GRAPHIC DEPICTION BASED ON INFORMATION GATHERED FROM VARIOUS SOURCES OF RECORD AND AVAILABLE MONUMENTATION FOUND DURING THE FIELD SURVEY. NO EASEMENTS WERE RESEARCHED OR PLOTTIED. PROPERTY LINES AND LINES OF TITLE WERE NOT INVESTIGATED NOR SURVEYED. NO PROPERTY MONUMENTS WERE SET.

APN 738-070-07 I OVERALL PROJECT AREA

CVL03147 Marshall Junction

Equipment Lease Area All that certain lease area being a portion of the Southeast quarter of the Northwest quarter of Section 14, Township 11 South, Range 22 East M.D.M. lying Westerly of Millerton Rood and being more particularly described as follows: Beginning at a point which bears North 89"22'28" East, 209.25 feet from the Southwest corner of the Southeast quarter of the Northwest quarter of Section 14. Township 11 South. Range 22 East M.D.M.: thence North 02'37'32" West, 57.63 feet to the True Point of Beginning; thence from said point of beginning North 27'14'38" West, 15.00 feet; thence North 62'45'22" East, 20.00 feet; thence South 27'14'38" East, 15.00 feet; thence South 62'45'22" West, 20.00 feet to the point of beginning.

Tower Lease Area

\

\ \

\

PRATHER,

\ . v ;\

\ ,\

\ \

\

CA

\ \

\

\

\

\ \

PROJECT

N.T.S.

\ \

\ \

M.N.

VICINITY MAP

Cl t--t---t----1--t--t---t--i w e5 0:: a... a... <( t--t---t----1--t--t---t--i

I­(/) :::::> a... 0 or::;

w

All that certain lease area being a portion of the Southwest quarter of the Northwest quarter of Section 14, Township 11 South, Range 22 East M.D.M. lying Westerly of Millerton Road and being more particularly described as follows: Beginning at a point which bears South 89"22'28" West, 229.12 feet from the Southwest corner of the Southeast quarter of the Northwest quarter of Section 14, Township 11 South, Range 22 East M.D.M.; thence North 0'37'32" West, 143.36 feet to the True Point of Beginning; thence from said point of beginning North 87'01'29" West, 25.00 feet; thence North 2'58'31" East, 25.00 feet; thence South 87'01'29" East, 25.00 feet; thence South 2'58'31" West, 25.00 feet to the point of beginning.

Together with on easement for access and utility purposes, twenty feet in width, the centerline of which is described as follows: Beginning at a point which bears North 27'14'38" West 10.0 feet from the North most corner of the above described Equipment Lease Area; thence from said point of beginning North 62'45'22" East 40.00 feet to the parcel boundary.

\ \ \ \

-

- -

_,,

-I I

-+

Also together with an easement for access and utility purposes, twenty feet in width, the centerline of which is described as follows: Beginning at a point which bears North 27'14'38" West 10.0 feet from the North most corner of the above described Equipment Lease Area; thence from said point of beginning South 62'45'22" West 16.71 feet; thence North 80'47'37" West 435. 73 feet more or less to the above described Antenna Lease Are .

Also together with an easement for grading purposes, being 60.0 fee by 60.0 feet centered on and surrounding the above described Antenna ease

- A.PN 138-070-69 Areg _

- - -

\ \

PROPOSED NON-EXCLUSIVE 2o:ct LESSEE . ACCESS\.& UTILITY. EASEMENT

--- --- -PROPCJSED LESSEE

EQUIPMENT LEASE ARE~ • Cb.fAVEMENT --- ---

1 I :

/ ~'jl/T:7:/ L .. · ·, ·' ~' r I

:' f .' \.<>

' :..;. ,• '"i ; .1.4 Oak 14"bak " :' -., / ~-;.-:::::'.{:.;1l··,_; ,'>r,--, { \ • I 14;Qak/ ,.__.,,,-,1- \ l'1<.~- -~'. ·---'- 't._ ___ ,.--.- I

,-'"''"I'j~;.;-:t <"' ,.;---· < afoak :>.,

' 't ~ , !

,, 17

., ~-I

/

'._<··'1'4"6.~/k, '~;;_:·

-i- -! -r~'l c=?t'-,, ' -..L~ -•-- • I -- '

I I -i--.,

I

-L__ I

I I I

\-

12·ooko.

14'."l)O'k '' ·.-/ ~ ~ -·

A

- - ---,..-

_.---l--

APN 138-070-07

:'\ __

---,)

- - -

---

c ,· .. \ \' \

\ <:.

'- ,;;, /1 v' I \)-,I

I I\

'

'. \

P~OPOSED\NON-EX LUSIVE 20.0' LESSEE , ACCE$S & UTI TY EASEMENT

, 20"0ak ' 22"0ak

' - -·-----~ ~ ----_-,

' 57.63

" --

\ \

\ \

'~)

\ \

\ \

\ { \

\ // •, \ rococom

~ \__ - - ---:"-- (/)

1111 .-l"')(OCXJ 0000 I I I I ooc-.J....-

i':- --(J

NO UTILITY SERVICES NOTED IN AREA CLOSEST UTILITIES 3300'± ALONG PUBLIC RIGHT OF WAY

LEASE AREA DETAIL

:z: ............... 0 0

cnr--..--..--....---r---. 2i a::

Sheet

C=l

Page 31: STEVEN E. WHITE, DIRECTOR

APN: 138-070-66

PROPOSED AT&T 25'-0"x25'-0"MONO-BROADLEAF LEASE AREA

SEE OVERALL SITE PLAN1

A-1.1

EXISTING 60'-0" WIDERIGHT OF WAY

MILLERTON ROAD

PROPOSED AT&T 15'-0"x20'-0"EQUIPMENT LEASE AREA

MILLERTON ROAD

OAK VIEW DRIVE

MO

RGAN

CAN

YON

ROAD

MILLERTON ROAD

APN: 138-070-69EXISTING OVERHEAD POWERLINES

EXISTING POWER POLE,PROPOSED AT&T POWER

P.O.F.

1 NOT TO SCALEUTILITY SITE PLAN

NORTH

PL

AN

N

OR

TH

PROPOSED AT&TUNDERGROUND POWER

UTILITY SITE PLAN

A-1.0

ALL PROPERTY BOUNDARIES, ORIENTATION OF TRUE NORTH &STREET HALF-WIDTHS HAVE BEEN OBTAINED FROM A TAX PARCEL

MAP & EXISTING DRAWINGS & ARE APPROXIMATE.

NOTES:

1. NO GRADING OR PERMANENT CONSTRUCTION SHALL OCCURWITHIN DRIP LINES OF TREES THAT ARE TO REMAIN WITHOUT ARBORISTAPPROVAL.

2. PRIOR TO CONSTRUCTION, GENERAL CONTRACTOR TO CONTACTDIGALERT TO MARK OUT EXISTING UNDERGROUND UTILITIES. IN THEEVENT OF CONFLICTS, CONTRACTOR TO CONTACT PDC.

THIS IS NOT A SITE SURVEY

PREPARED FOR

REV DESCRIPTIONDATE

SHEET TITLE:

SHEET NUMBER:

CHECKED BY:

DRAWN BY:

PROJECT NO:

IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE

DIRECTION OF A LICENSED PROFESSIONALENGINEER, TO ALTER THIS DOCUMENT.

Vendor:

Licensee:

Architect:

AT&T SITE NO:

162.2380

CVL03147

1520 River Park DriveSacramento, California 95815

12/07/18 90% ZD

2600 Camino RamonSan Ramon, California 94583

Issued For:

CVL03147MARSHALLJUNCTION

MILLERTON ROADPRATHER, CA 93656

MWS

TST

01/08/19 100% ZD

Page 32: STEVEN E. WHITE, DIRECTOR

2 1"=50'ENLARGED SITE PLAN

NORTH

PL

AN

N

OR

TH

1" = 50.0'

0' 10' 50' 100'

PROPOSED AT&T 25'-0"x25'-0"MONO-BROADLEAF LEASE AREA

SEE MONO-BROADLEAFEQUIPMENT LAYOUT PLAN

1A-2.2

APN: 138-070-66APN: 138-070-69

EXISTING 60'-0" WIDERIGHT OF WAY

EDGE OF EXISTINGPAVEMENT

MILLERTO

N ROAD

EXISTING FENCE

±143'-4"

±232'-10"

PROPOSED AT&T 20'-0" WIDEACCESS AND UTILITY EASEMENT

SEE ENLARGED SITE PLAN ATNEW ACCESS DRIVEWAY

3A-1.1

PROPOSED AT&T15'-0"x20'-0" EQUIPMENT

LEASE AREA

PROPOSED AT&T 20'-0" WIDEALL-WEATHER ACCESS ROAD

(NOT TO FIRE STANDARDS)

EXISTING TREESTO REMAIN

PROPOSED AT&T 60'-0"x60'-0"GRADING EASEMENT

±40'-9"

±57'

-7"

APPROXIMATE LOCATION OFEXISTING TREES

NOTE:1. THE PROPOSED AT&T LEASE AREAS AND GRAVEL ACCESS ROAD GRADINGPLANS TO BE PROVIDED BY A LICENSED CIVIL ENGINEER.

2. FINAL ROUTE OF THE ACCESS ROAD TO BE DETERMINED BY CIVIL ENGINEER.

3. FINAL ACCESS ROUTE WILL DETERMINE WHAT EXISTING TREES OR OTHERLANDSCAPING TO BE REMOVED OR REPLACED

3 1"=10'ENLARGED SITE PLAN AT NEW ACCESS DRIVEWAY

NORTH

PL

AN

N

OR

TH

20'10'2'0'

1" = 10.0'

EDGE OF EXISTING PAVEMENT

PORTION OF EXISTING CATTLE FENCE TO BEREMOVED AND REPLACED WITH NEW CATTLEFENCE AND 12'-0" WIDE ACCESS GATE TOCONNECT TO PROPOSED AT&T EQUIPMENTLEASE AREA CHAIN LINK FENCE, NEW CATTLEFENCE TO MATCH EXISTING

R25'

-0"

PROPOSED AT&T 20'-0" WIDEACCESS AND UTILITY EASEMENT

PROPOSED AT&T UNDERGROUNDHYBRID CABLES (±446'-0")

PROPOSED AT&T 20'-0" WIDEALL-WEATHER ACCESS ROADAND DRIVEWAY

PROPOSED AT&T POWER ANDTELCO P.O.F. TO BE DETERMINED

PROPOSED AT&T 15'-0"x20'-0"EQUIPMENT LEASE AREA

SEE EQUIPMENTLAYOUT PLAN

1A-2.1

MILLERTO

N ROAD

PROPOSED AT&T 20'-0" WIDEALL-WEATHER ACCESS ROAD

(NOT TO FIRE STANDARDS)

PROPOSED AT&T KNOX BOXMOUNTED ON FENCE

APN: 138-070-69

1 1"=500'OVERALL SITE PLAN

NORTH

PL

AN

N

OR

TH

1" = 500.0'

0' 100' 500' 1000'

APN: 138-070-66

APN: 138-070-31

APN: 138-070-33

APN: 138-070-68

APN

: 138

-070

-02

APN: 138-070-20

APN: 138-070-07

APN: 138-070-65

APN: 138-070-68

APN: 138-070-71

APN: 138-070-70PROPOSED AT&T 25'-0"x25'-0"MONO-BROADLEAF LEASE AREA

SEE ENLARGED SITE PLAN2

A-1.1

EXISTING 60'-0" WIDERIGHT OF WAY

MILLERTON ROAD

PROPOSED AT&T 15'-0"x20'-0"EQUIPMENT LEASE AREA

APN: 138-070-15

APN

: 138

-070

-01

PROPOSED AT&T 60'-0"x60'-0"GRADING EASEMENT

APN: 138-070-69

OVERALL ANDENLARGED SITE

PLANS

A-1.1

ALL PROPERTY BOUNDARIES, ORIENTATION OF TRUE NORTH &STREET HALF-WIDTHS HAVE BEEN OBTAINED FROM A TAX PARCEL

MAP & EXISTING DRAWINGS & ARE APPROXIMATE.

NOTES:

1. NO GRADING OR PERMANENT CONSTRUCTION SHALL OCCURWITHIN DRIP LINES OF TREES THAT ARE TO REMAIN WITHOUT ARBORISTAPPROVAL.

2. PRIOR TO CONSTRUCTION, GENERAL CONTRACTOR TO CONTACTDIGALERT TO MARK OUT EXISTING UNDERGROUND UTILITIES. IN THEEVENT OF CONFLICTS, CONTRACTOR TO CONTACT PDC.

THIS IS NOT A SITE SURVEY

PREPARED FOR

REV DESCRIPTIONDATE

SHEET TITLE:

SHEET NUMBER:

CHECKED BY:

DRAWN BY:

PROJECT NO:

IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE

DIRECTION OF A LICENSED PROFESSIONALENGINEER, TO ALTER THIS DOCUMENT.

Vendor:

Licensee:

Architect:

AT&T SITE NO:

162.2380

CVL03147

1520 River Park DriveSacramento, California 95815

12/07/18 90% ZD

2600 Camino RamonSan Ramon, California 94583

Issued For:

CVL03147MARSHALLJUNCTION

MILLERTON ROADPRATHER, CA 93656

MWS

TST

01/08/19 100% ZD

Page 33: STEVEN E. WHITE, DIRECTOR

PROPOSED AT&T 30KW DIESEL GENERATORWITH 190 GALLON FUEL TANK, MOUNTEDON 8'-0"x14'-0" CONCRETE SLAB

PROPOSED AT&T GPS ANTENNA

(3) PROPOSED AT&T SURGE SUPPRESSORSMOUNTED ON UNISTRUT TO EQUIPMENT

SHELTER (VERTICALLY STACKED)

PROPOSED AT&T DC POWER PLANT RACKMOUNTED INSIDE EQUIPMENT SHELTER

PORTION OF EXISTING CATTLE FENCE TO BE REMOVEDAND REPLACED WITH NEW CATTLE FENCE AND 12'-0"WIDE ACCESS GATE TO CONNECT TO PROPOSED AT&TEQUIPMENT LEASE AREA CHAIN LINK FENCE, NEWCATTLE FENCE TO MATCH EXISTING

PROPOSED AT&T TRANSPORT RACKMOUNTED INSIDE EQUIPMENT SHELTER

PROPOSED AT&T WALL MOUNTED HVAC

PROPOSED AT&T UNDERGROUNDHYBRID CABLES

(4) PROPOSED AT&T 6"Ø CONDUIT STUB-UPS

PROPOSED AT&T RADIO RACK MOUNTEDINSIDE EQUIPMENT SHELTER

PROPOSED AT&T 200A SERVICE METER &DISCONNECT MOUNTED ON A UTILITY H-FRAME

PROPOSED AT&T 3'-0" WIDE x1'-0" DEEP CONCRETE STEP

PROPOSED AT&T TELCO BOX WITH CIENA BOXABOVE MOUNTED ON A UTILITY H-FRAME

PROPOSED AT&T KNOX BOX MOUNTEDON CHAIN LINK FENCE

PROPOSED AT&T UNDERGROUND TELCO

PROPOSED AT&T CAM-LOKGENERATOR INTERFACE

PROPOSED AT&T 30 CIRCUIT LOAD CENTER& AUTOMATIC TRANSFER SWITCH

PROPOSED AT&T HOODED &DOWN-TILTED LED SECURITY LIGHTS ATFRONT & BACK OF EQUIPMENT SHELTER

PROPOSED AT&T 3'-0"x6'-0" CONCRETESTOOP WITH 1'-0" DEEP STEP

PROPOSED AT&T PORTABLE FIRE EXTINGUISHERMOUNTED ON UTILITY H-FRAME.  INSTALL INWEATHERPROOF CABINET & LABEL.EXTINGUISHER SHALL BE RATED 4A:80B:C ORAS REQUIRED BY LOCAL FIRE AUTHORITY

PROPOSED AT&T PORTABLE FIRE EXTINGUISHERMOUNTED INSIDE EQUIPMENT SHELTER.

EXTINGUISHER SHALL BE RATED 4A:80B:C ORAS REQUIRED BY LOCAL FIRE AUTHORITY

PROPOSED AT&T 6'-0" TALL CHAINLINK FENCE WITH (3) STRANDS OF

BARBED WIRE AND 6'-0" WIDEACCESS GATE

PROPOSED AT&T 8'-0"x8'-0" EQUIPMENTSHELTER ON A 8'-0"x14'-0" CONCRETE SLAB

PROPOSED AT&T 15'-0"x20'-0"EQUIPMENT LEASE AREA

1 1/2" = 1'-0"EQUIPMENT LAYOUT PLAN

5' 10'1'

1/2" = 1'-0"

0'N

O

R

T

H

P

L

A

N

N

O

R

T

H

8x8 CONCRETEWALK-IN CABINET

PROPOSED AT&T 20'-0" WIDEACCESS AND UTILITY EASEMENT

PROPOSED AT&T GRAVEL BED

TOP OF PROPOSED EQUIPMENT SLAB1.0' A.G.L. (829.0' A.M.S.L.)

EXISTING GRADE LEVEL0.0' A.G.L. (828.0' A.M.S.L.)

TOP OF PROPOSED STOOP1.0' A.G.L. (829.0' A.M.S.L.)

PROPOSED AT&T 20'-0" WIDE ALL-WEATHERACCESS ROAD AND DRIVEWAY

PORTION OF EXISTING CATTLE FENCE TO BE REMOVEDAND REPLACED WITH NEW CATTLE FENCE AND 12'-0"WIDE ACCESS GATE TO CONNECT TO PROPOSED AT&TEQUIPMENT LEASE AREA CHAIN LINK FENCE, NEWCATTLE FENCE TO MATCH EXISTING

PROPOSED AT&T UNDERGROUND TELCO

20'-0" PROPOSED EQUIPMENT LEASE AREA

3'-0" 8'-0" WALK-IN CABINET 6'-0" CONCRETE SLAB 3'-0"

7'-0" 6'-0" ACCESS GATE 7'-0"

3'-0" 6'-0" CONCRETE STOOP 2'-0" 3'-0" CONCRETESTEP

6'-0"

9"6'-0" H-FRAME

1'-1

0"8'

-0" E

QUI

PMEN

T SL

AB

1'-0

"ST

EP4'

-2"

15'-0

" PRO

POSE

D E

QUI

PMEN

T LE

ASE

ARE

A

3'-1

"

1'-2

"1'

-0"

3'-0

" CO

NC

RETE

STO

OP

8"

NOTE:1. THE PROPOSED AT&T LEASE AREAS AND GRAVEL ACCESSROAD GRADING PLANS TO BE PROVIDED BY A LICENSED CIVILENGINEER.

2. FINAL ROUTE OF THE ACCESS ROAD TO BE DETERMINED BYCIVIL ENGINEER.

3. FINAL ACCESS ROUTE WILL DETERMINE WHAT EXISTING TREESOR OTHER LANDSCAPING TO BE REMOVED OR REPLACED

EQUIPMENTLAYOUT PLAN

A-2.1

PREPARED FOR

REV DESCRIPTIONDATE

SHEET TITLE:

SHEET NUMBER:

CHECKED BY:

DRAWN BY:

PROJECT NO:

IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE

DIRECTION OF A LICENSED PROFESSIONALENGINEER, TO ALTER THIS DOCUMENT.

Vendor:

Licensee:

Architect:

AT&T SITE NO:

162.2380

CVL03147

1520 River Park DriveSacramento, California 95815

12/07/18 90% ZD

2600 Camino RamonSan Ramon, California 94583

Issued For:

CVL03147MARSHALLJUNCTION

MILLERTON ROADPRATHER, CA 93656

MWS

TST

01/08/19 100% ZD

Page 34: STEVEN E. WHITE, DIRECTOR

1 1/2" = 1'-0"MONO-BROADLEAF EQUIPMENT LAYOUT PLAN

5' 10'1'

1/2" = 1'-0"

0'

10'-0" RADIUS OFLOWEST BRANCHES

SEE ANTENNALAYOUT PLAN

PROPOSED AT&T UNDERGROUNDHYBRID CABLES (±446'-0")

(4) PROPOSED AT&T 6"ØCONDUIT STUB-UPS

PROPOSED AT&T 25'-0"x25'-0"MONO-BROADLEAF

EQUIPMENT LEASE AREA

NO

RTH

PL

AN

N

OR

TH

PROPOSED AT&T 20'-0" WIDEACCESS AND UTILITY EASEMENT

PROPOSED AT&T CABLEPROTECTION COVER

1A-3.1

PROPOSED AT&TMONO-BROADLEAF

EXISTING GRADE LEVEL0.0' A.G.L. (916.0' A.M.S.L.)

PROPOSED AT&T 20'-0" WIDEALL-WEATHER ACCESS ROAD(NOT TO FIRE STANDARDS)

PROPOSED AT&T 6'-0" WIDECHAIN LINK FENCE GATE

PROPOSED AT&T 6'-0" TALLCHAIN LINK FENCE WITH (3)STRANDS OF BARBED WIRE

AND 6'-0" WIDE ACCESSGATE

PROPOSED AT&T 60'-0"x60'-0"GRADING EASEMENT

NOTE:1. THE PROPOSED AT&T LEASE AREAS AND GRAVEL ACCESS ROADGRADING PLANS TO BE PROVIDED BY A LICENSED CIVIL ENGINEER.

2. FINAL ROUTE OF THE ACCESS ROAD TO BE DETERMINED BY CIVILENGINEER.

3. FINAL ACCESS ROUTE WILL DETERMINE WHAT EXISTING TREES OROTHER LANDSCAPING TO BE REMOVED OR REPLACED

MONO-BROADLEAFEQUIPMENT

LAYOUT PLAN

A-2.2

PREPARED FOR

REV DESCRIPTIONDATE

SHEET TITLE:

SHEET NUMBER:

CHECKED BY:

DRAWN BY:

PROJECT NO:

IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE

DIRECTION OF A LICENSED PROFESSIONALENGINEER, TO ALTER THIS DOCUMENT.

Vendor:

Licensee:

Architect:

AT&T SITE NO:

162.2380

CVL03147

1520 River Park DriveSacramento, California 95815

12/07/18 90% ZD

2600 Camino RamonSan Ramon, California 94583

Issued For:

CVL03147MARSHALLJUNCTION

MILLERTON ROADPRATHER, CA 93656

MWS

TST

01/08/19 100% ZD

Page 35: STEVEN E. WHITE, DIRECTOR

NO SCALERF SCHEDULE2

1/2" = 1'-0" ANTENNA LAYOUT PLAN1

5' 10'1'

1/2" = 1'-0"

0'

SEC

TOR

AA

ZIM

UTH

SECTOR CAZIMUTH 95°

(12) PROPOSED AT&T RRUS,(6) RRUS PER SECTOR,VERTICALLY STACKED

PROPOSED AT&T MONO-BROADLEAF

SECTOR

ALPHA

ANTENNA MODEL NO. AZIMUTH CENTERLINE RRU FIBER LENGTH COAX LENGTH COAX DIA. RRU NO.

RF SCHEDULE

± 50'-0"

TMA

-10°A1

A2

A3

± 90'-0"

-

-

GAMMA

C1

C2

C3

-

-

CCI TPA-45R-KU8AA-K

CCI BSA-M65R-BUU-H6-K

-

-

-

--

-

-

2

2

2

2

2

2

-

-

-

--

-

-

(1) 4449 B5/B12 / (1) 8843 B2/B66A

(2) 4415 B30

(1) 4478 B14 / (1) 4415 B25

PROPOSED AT&T STAND-OFF

3-6A-3.2

NORTH

PL

AN

N

OR

TH

RF DATA SHEET v1.00.00 DATED 10/03/2018 EQUIPMENT IS PRELIMINARY AND SUBJECT TO CHANGE

NOTE: ANTENNA POSITIONS ARE LEFT TO RIGHT FROM FRONT OF ANTENNA

± 50'-0"

(6) PROPOSED AT&T ANTENNAS,(3) PER SECTOR

(3) PROPOSED AT&T SURGE SUPPRESSORS,(1) PER SECTOR

7A-3.2

1-2A-3.2

10°

95°

CCI TPA-45R-KU8AA-K

± 50'-0"

95°

95°

CCI TPA-45R-KU8AA-K

CCI BSA-M65R-BUU-H6-K

CCI TPA-45R-KU8AA-K

± 50'-0"

± 50'-0"

± 50'-0"

(1) 4449 B5/B12 / (1) 8843 B2/B66A

(2) 4415 B30

(1) 4478 B14 / (1) 4415 B25

-

± 90'-0"

± 90'-0"

± 90'-0"

± 90'-0"

± 90'-0"

NOTE: AT&T TO INSTALL "LEAF SOCKS" ON ALLPROPOSED PANEL ANTENNAS & RRH UNITS. ALL

ANTENNAS & EQUIPMENT TO BE PAINTED FLAT GREEN

10'-0"LENGTH @ LOWEST BRANCHES

8'-0"

LENGTH OF BRANCHES

@ ANTENNAS

SEC

TOR

AA

ZIM

UTH

10°

SEC

TOR

AA

ZIM

UTH

10°

4'-0

" TYP

.4'

-0" T

YP.

3'-0" TYP.

PROPOSED AT&T CROSS ARM

ANTENNA LAYOUTPLAN & SCHEDULE

A-3.1

PREPARED FOR

REV DESCRIPTIONDATE

SHEET TITLE:

SHEET NUMBER:

CHECKED BY:

DRAWN BY:

PROJECT NO:

IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE

DIRECTION OF A LICENSED PROFESSIONALENGINEER, TO ALTER THIS DOCUMENT.

Vendor:

Licensee:

Architect:

AT&T SITE NO:

162.2380

CVL03147

1520 River Park DriveSacramento, California 95815

12/07/18 90% ZD

2600 Camino RamonSan Ramon, California 94583

Issued For:

CVL03147MARSHALLJUNCTION

MILLERTON ROADPRATHER, CA 93656

MWS

TST

01/08/19 100% ZD

Page 36: STEVEN E. WHITE, DIRECTOR

2-1/4" STANDARDGALVINIZED PIPE MOUNT

11"

11"

9"2'

-3"

GROUND TO ANTENNA GROUNDBAR OR BUILDING STEEL

SURGE SUPPRESSION SYSTEMFOR USE AT ANTENNA SECTORSCLOSER THAN 18 FEET APART

MFR STANDARD CLIPS

2-1/4" STANDARDGALVINIZED PIPE MOUNT

MFR STANDARD PIPEMOUNT HARDWARE

RAYCAP DC6-48-60-18-8F & DC6-48-60-0-8F SURGE SUPPRESSION SOLUTION

COLOR: BLACK/SILVER

DIMENSIONS: 11" DIA X 27" TALL W/ 9" BASE

WEIGHT: +/- 50 LBS. (INCLUDING MOUNTING HARDWARE)

SURGE SUPPRESSION SYSTEMFOR USE AT ANTENNA SECTORSCLOSER THAN 18 FEET APART

COAX LINES TO ANTENNAS

MFR STANDARDPIPE MONTHARDWARE

7 1-1/2"= 1'-0"DC SURGE SUPRESSION (SQUID)

FRONT VIEW SIDE VIEW

TOP VIEW

3 1-1/2"= 1'-0"ERICSSON 4415 B25 REMOTE RADIO UNIT

ERICSSON 4415 B25 REMOTE RADIO UNIT

COLOR: WHITE

DIMENSIONS: 16.5" TALL X 13.4" WIDE X 5.9" DEEP (INCLUDING SUNSHIELD)

WEIGHT: +/- 50 LBS. (INCLUDING MOUNTING HARDWARE)

4415 B25 WITH SUNSHIELD

16.5

"12

"C

LR

13.4"

16"

CLR 5.9"

2-3/8" DIA. GALV.STL. PIPE (LENGTHAS REQUIRED)

ERICSSON GALV.STL. MOUNTINGBRACKETS PART #:SXK 125 0245/1

(2) 3/8"Ø GALV.STL. BOLTS, NUTS &LOCK WASHERS

(2) 3/8"Ø GALV.STL. BOLTS, NUTS &LOCK WASHERS

5.9"

13.4

"

ERICSSON RRH 4478 B14 REMOTE RADIO UNIT

COLOR: WHITE

DIMENSIONS: 16.5" TALL X 17" WIDE X 7.7" DEEP (INCLUDING SUNSHIELD)

WEIGHT: +/- 59.9 LBS. (INCLUDING MOUNTING HARDWARE)

4 1-1/2"= 1'-0"ERICSSON RADIO 4478 B14 REMOTE RADIO UNIT

FRONT VIEW SIDE VIEW

TOP VIEW

4478 B14 WITH SUNSHIELD

16.5

"12

"C

LR

13.4"

16"

CLR 7.7"

2-3/8" DIA. GALV.STL. PIPE (LENGTHAS REQUIRED)ERICSSON GALV.STL. MOUNTINGBRACKETS PART #:SXK 125 0245/1

(2) 3/8"Ø GALV.STL. BOLTS, NUTS &LOCK WASHERS

(2) 3/8"Ø GALV.STL. BOLTS, NUTS &LOCK WASHERS

7.7"

13.4

"

FRONT VIEW SIDE VIEW

TOP VIEW

5 1-1/2"= 1'-0"ERICSSON 4449 B5/B12 REMOTE RADIO UNIT

ERICSSON 4449 B5/B12 REMOTE RADIO UNIT

COLOR: WHITE

DIMENSIONS: 15" TALL X 13.2" WIDE X 10.2" DEEP (INCLUDING SUNSHIELD)

WEIGHT: +/- 75 LBS. (INCLUDING MOUNTING HARDWARE)

4415 B25 WITH SUNSHIELD

15"

12"

CLR

13.2"

16"

CLR 10.2"

2-3/8" DIA. GALV.STL. PIPE (LENGTHAS REQUIRED)

ERICSSON GALV.STL. MOUNTINGBRACKETS PART #:SXK 125 0245/1

(2) 3/8"Ø GALV.STL. BOLTS, NUTS &LOCK WASHERS

(2) 3/8"Ø GALV.STL. BOLTS, NUTS &LOCK WASHERS

10.2"

15"

FRONT VIEW SIDE VIEW

TOP VIEW

6 1-1/2"= 1'-0"ERICSSON 8843 B2/B66A REMOTE RADIO UNIT

ERICSSON 8843 B2/B66A REMOTE RADIO UNIT

COLOR: WHITE

DIMENSIONS: 15" TALL X 13.2" WIDE X 10.2" DEEP (INCLUDING SUNSHIELD)

WEIGHT: +/- 75 LBS. (INCLUDING MOUNTING HARDWARE)

4415 B25 WITH SUNSHIELD

15"

12"

CLR

13.2"

16"

CLR 10.2"

2-3/8" DIA. GALV.STL. PIPE (LENGTHAS REQUIRED)

ERICSSON GALV.STL. MOUNTINGBRACKETS PART #:SXK 125 0245/1

(2) 3/8"Ø GALV.STL. BOLTS, NUTS &LOCK WASHERS

(2) 3/8"Ø GALV.STL. BOLTS, NUTS &LOCK WASHERS

13.2"

15"

98.7

"

==

8.2"15.4"

ANTENNASUPPORT PIPE

MECHANICALDOWNTILT

BRACKET

ANTENNAWEIGHTDIMENSIONS

CCI TPA-45R-KU8AA-K79.4 LBS98.7.0" (H) x 15.4" (W) x 8.2" (D)=

1 3/4" = 1'-0"PROPOSED ANTENNA SPEC

FRONT SIDE PERSPECTIVE

EQUIPMENT SUBJECT TO CHANGE

72"

==

9.7"28.5"

ANTENNASUPPORT PIPE

MECHANICALDOWNTILT

BRACKET

ANTENNAWEIGHTDIMENSIONS

CCI BSA-M65R-BUU-H6-K101 LBS72" (H) x 28.5" (W) x 9.7" (D)=

2 3/4" = 1'-0"PROPOSED ANTENNA SPEC

FRONT SIDE PERSPECTIVE

EQUIPMENT SUBJECT TO CHANGE

ANTENNADETAILS

A-3.2

PREPARED FOR

REV DESCRIPTIONDATE

SHEET TITLE:

SHEET NUMBER:

CHECKED BY:

DRAWN BY:

PROJECT NO:

IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE

DIRECTION OF A LICENSED PROFESSIONALENGINEER, TO ALTER THIS DOCUMENT.

Vendor:

Licensee:

Architect:

AT&T SITE NO:

162.2380

CVL03147

1520 River Park DriveSacramento, California 95815

12/07/18 90% ZD

2600 Camino RamonSan Ramon, California 94583

Issued For:

CVL03147MARSHALLJUNCTION

MILLERTON ROADPRATHER, CA 93656

MWS

TST

01/08/19 100% ZD

Page 37: STEVEN E. WHITE, DIRECTOR

10' 20'0' 2'

1/8" = 1'-0"2 1/8" = 1'-0"

EAST ELEVATION 1 1/8" = 1'-0"NORTH ELEVATION

10' 20'0' 2'

1/8" = 1'-0"

PROPOSED AT&TMONO-BROADLEAF

TOP OF PROPOSED STEEL57.0' A.G.L.

TOP OF PROPOSED MONO-BROADLEAF61.0' A.G.L.

CENTERLINE OF PROPOSED ANTENNAS50.0' A.G.L.

BOTTOM OF PROPOSED BRANCHES20.0' A.G.L.

TOP OF PROPOSED STEEL57.0' A.G.L.

TOP OF PROPOSED MONO-BROADLEAF61.0' A.G.L.

EXISTING GRADE LEVEL0.0' A.G.L. (916.0' A.M.S.L.)

NOTE: BRANCHES SHOWN AREFOR ILLUSTRATIVE PURPOSES

ONLY, NOT TO SCALE

PROPOSED AT&T ANTENNASW/ ASSOCIATED TOWER

MOUNTED EQUIPMENT

PROPOSED AT&TMONO-BROADLEAF

NOTE: AT&T TO INSTALL "LEAF SOCKS"ON ALL PROPOSED PANEL ANTENNAS

& RRH UNITS. ALL ANTENNAS &EQUIPMENT TO BE PAINTED FLAT GREEN

25'-0" WIDE PROPOSED AT&TMONO-BROAD LEAF LEASE AREA

25'-0" WIDE PROPOSED AT&TMONO-BROADLEAF LEASE AREA

PROPOSED AT&T ANTENNASW/ ASSOCIATED TOWER

MOUNTED EQUIPMENT

CENTERLINE OF PROPOSED ANTENNAS50.0' A.G.L.

EXISTING GRADE LEVEL0.0' A.G.L. (916.0' A.M.S.L.)

BOTTOM OF PROPOSED BRANCHES20.0' A.G.L.

EXISTING GRADE LEVEL0.0' A.G.L. (828.0' A.M.S.L.)

TOP OF PROPOSED EQUIPMENT SLAB1.0' A.G.L. (829.0' A.M.S.L.)

PROPOSED AT&T UTILITY H-FRAME

PROPOSED AT&T 30KW DIESEL GENERATORWITH 190 GALLON FUEL TANK, MOUNTED

ON 8'-0"x14'-0" CONCRETE SLAB

PROPOSED AT&T 8'-0"x8'-0"CONCRETE WALK-IN CABINETON 8'-0"x14'-0" CONCRETE SLAB

PROPOSED AT&T 6'-0" TALL CHAINLINK FENCE WITH (3) STRANDS OF

BARBED WIRE AND 6'-0" WIDEACCESS GATE

EXISTING GRADE LEVEL0.0' A.G.L. (828.0' A.M.S.L.)

TOP OF PROPOSED EQUIPMENT SLAB1.0' A.G.L. (829.0' A.M.S.L.)

60'-0" WIDE PROPOSED AT&T GRADING EASEMENT

60'-0" WIDE PROPOSED AT&T GRADING EASEMENT

NOTE: POLE TO BE DESIGNED TO BECO-LOCATEABLE FOR AT LEAST (1)

ONE FUTURE CARRIER

20'-0" WIDE PROPOSED AT&TEQUIPMENT LEASE AREA

PROPOSED AT&T 6'-0" TALL CHAINLINK FENCE WITH 3 STRAND BARBEDWIRE AND 6'-0" WIDE ACCESS GATE

PROPOSED AT&T 6'-0" TALL CHAINLINK FENCE WITH 3 STRAND BARBEDWIRE AND 6'-0" WIDE ACCESS GATE

PROPOSED AT&T UTILITY H-FRAMEPROPOSED AT&T 30KW DIESEL GENERATOR

WITH 190 GALLON FUEL TANK, MOUNTEDON 8'-0"x14'-0" CONCRETE SLAB

PROPOSED AT&T 8'-0"x8'-0"CONCRETE WALK-IN CABINET

ON 8'-0"x14'-0" CONCRETE SLAB

15'-0" PROPOSED AT&TEQUIPMENT LEASE AREA

PROPOSED AT&T 6'-0" TALL CHAINLINK FENCE WITH (3) STRANDS OF

BARBED WIRE AND 6'-0" WIDEACCESS GATE

PROPOSED AT&T CATTLE FENCE,RECONNECT TO EXISTING

CATTLE FENCE. NEW FENCINGTO MATCH EXISTING FENCING

PORTION OF EXISTING CATTLE FENCE TO BEREMOVED AND REPLACED WITH NEW CATTLEFENCE AND 12'-0" WIDE ACCESS GATE TOCONNECT TO PROPOSED AT&T EQUIPMENTLEASE AREA CHAIN LINK FENCE, NEW CATTLEFENCE TO MATCH EXISTING

NOTE: THE PROPOSED AT&T LEASE AREAS ANDALL-WEATHER GRAVEL ACCESS ROAD GRADING WILL

BE DESIGNED BY A LICENSED CIVIL ENGINEER. THEFINAL DESIGN, GRADING, AND DIRECTION OF THE

ACCESS ROAD WILL DETERMINED, AS WELL AS WHATEXISTING TREES OR OTHER LANDSCAPING TO BE

REMOVED OR REPLACED

PROPOSEDELEVATIONS

A-4.1

PREPARED FOR

REV DESCRIPTIONDATE

SHEET TITLE:

SHEET NUMBER:

CHECKED BY:

DRAWN BY:

PROJECT NO:

IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE

DIRECTION OF A LICENSED PROFESSIONALENGINEER, TO ALTER THIS DOCUMENT.

Vendor:

Licensee:

Architect:

AT&T SITE NO:

162.2380

CVL03147

1520 River Park DriveSacramento, California 95815

12/07/18 90% ZD

2600 Camino RamonSan Ramon, California 94583

Issued For:

CVL03147MARSHALLJUNCTION

MILLERTON ROADPRATHER, CA 93656

MWS

TST

01/08/19 100% ZD

Page 38: STEVEN E. WHITE, DIRECTOR

1 1/8" = 1'-0"SOUTH ELEVATION

10' 20'0' 2'

1/8" = 1'-0"2 1/8" = 1'-0"

WEST ELEVATION

10' 20'0' 2'

1/8" = 1'-0"

PROPOSED AT&TMONO-BROADLEAF

TOP OF PROPOSED STEEL57.0' A.G.L.

TOP OF PROPOSED MONO-BROADLEAF61.0' A.G.L.

CENTERLINE OF PROPOSED ANTENNAS50.0' A.G.L.

BOTTOM OF PROPOSED BRANCHES20.0' A.G.L.

TOP OF PROPOSED STEEL57.0' A.G.L.

TOP OF PROPOSED MONO-BROADLEAF61.0' A.G.L.

EXISTING GRADE LEVEL0.0' A.G.L. (916.0' A.M.S.L.)

PROPOSED AT&TMONO-BROADLEAF

25'-0" PROPOSED AT&TMONO-BROAD LEAF LEASE AREA

25'-0" PROPOSED AT&TMONO-BROADLEAF LEASE AREA

PROPOSED AT&T ANTENNASW/ ASSOCIATED TOWER

MOUNTED EQUIPMENT

CENTERLINE OF PROPOSED ANTENNAS50.0' A.G.L.

EXISTING GRADE LEVEL0.0' A.G.L. (916.0' A.M.S.L.)

BOTTOM OF PROPOSED BRANCHES20.0' A.G.L.

EXISTING GRADE LEVEL0.0' A.G.L. (828.0' A.M.S.L.)

TOP OF PROPOSED EQUIPMENT SLAB1.0' A.G.L. (829.0' A.M.S.L.)

PROPOSED AT&T UTILITY H-FRAME

PROPOSED AT&T 30KW DIESEL GENERATORWITH 190 GALLON FUEL TANK, MOUNTEDON 8'-0"x14'-0" CONCRETE SLAB

PROPOSED AT&T 8'-0"x8'-0"CONCRETE WALK-IN CABINET

ON 8'-0"x14'-0" CONCRETE SLABPROPOSED AT&T 6'-0" TALL CHAINLINK FENCE WITH (3) STRANDS OF

BARBED WIRE AND 6'-0" WIDEACCESS GATE

EXISTING GRADE LEVEL0.0' A.G.L. (828.0' A.M.S.L.)

TOP OF PROPOSED EQUIPMENT SLAB1.0' A.G.L. (829.0' A.M.S.L.)

NOTE: BRANCHES SHOWN AREFOR ILLUSTRATIVE PURPOSES

ONLY, NOT TO SCALE

NOTE: AT&T TO INSTALL "LEAF SOCKS"ON ALL PROPOSED PANEL ANTENNAS

& RRH UNITS. ALL ANTENNAS &EQUIPMENT TO BE PAINTED FLAT GREEN

NOTE: POLE TO BE DESIGNED TO BECO-LOCATEABLE FOR AT LEAST (1)

ONE FUTURE CARRIER

60'-0" PROPOSED AT&T GRADING EASEMENT

20'-0" PROPOSED AT&TEQUIPMENT LEASE AREA

60'-0" WIDE PROPOSED AT&T GRADING EASEMENT

PROPOSED AT&T 6'-0" TALL CHAINLINK FENCE WITH 3 STRAND BARBEDWIRE AND 6'-0" WIDE ACCESS GATE

PROPOSED AT&T 6'-0" TALL CHAINLINK FENCE WITH 3 STRAND BARBEDWIRE AND 6'-0" WIDE ACCESS GATE

PROPOSED AT&T ANTENNASW/ ASSOCIATED TOWER

MOUNTED EQUIPMENT

PROPOSED AT&T UTILITY H-FRAME

PROPOSED AT&T 6'-0" TALL CHAINLINK FENCE WITH (3) STRANDS OFBARBED WIRE AND 6'-0" WIDEACCESS GATE

PROPOSED AT&T 8'-0"x8'-0"CONCRETE WALK-IN CABINETON 8'-0"x14'-0" CONCRETE SLAB

15'-0" WIDE PROPOSED AT&TEQUIPMENT LEASE AREA

PORTION OF EXISTING CATTLE FENCE TO BEREMOVED AND REPLACED WITH NEW CATTLE

FENCE AND 12'-0" WIDE ACCESS GATE TOCONNECT TO PROPOSED AT&T EQUIPMENT

LEASE AREA CHAIN LINK FENCE, NEW CATTLEFENCE TO MATCH EXISTING PROPOSED AT&T CATTLE FENCE, RECONNECT

TO EXISTING CATTLE FENCE. NEW FENCINGTO MATCH EXISTING FENCING

NOTE: THE PROPOSED AT&T LEASE AREAS ANDALL-WEATHER GRAVEL ACCESS ROAD GRADING WILL

BE DESIGNED BY A LICENSED CIVIL ENGINEER. THEFINAL DESIGN, GRADING, AND DIRECTION OF THE

ACCESS ROAD WILL DETERMINED, AS WELL AS WHATEXISTING TREES OR OTHER LANDSCAPING TO BE

REMOVED OR REPLACED

PROPOSEDELEVATIONS

A-4.2

PREPARED FOR

REV DESCRIPTIONDATE

SHEET TITLE:

SHEET NUMBER:

CHECKED BY:

DRAWN BY:

PROJECT NO:

IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE

DIRECTION OF A LICENSED PROFESSIONALENGINEER, TO ALTER THIS DOCUMENT.

Vendor:

Licensee:

Architect:

AT&T SITE NO:

162.2380

CVL03147

1520 River Park DriveSacramento, California 95815

12/07/18 90% ZD

2600 Camino RamonSan Ramon, California 94583

Issued For:

CVL03147MARSHALLJUNCTION

MILLERTON ROADPRATHER, CA 93656

MWS

TST

01/08/19 100% ZD

Page 39: STEVEN E. WHITE, DIRECTOR

!(

!(

!(

!(

!(

!(

#*

^

^

·|}þ168

DOGCREEK

S AN JOAQ

UIN

R IVE

R

FRIANT-KERN CAN AL

LITTLE DRY CREEK

BIG DRY CREEK CANAL

Prather

Marshall Station

Humphrey's Station

Millerton Lake

CELL TOWERS WITHIN A 5-MILE RADIUS CUP 3635

Prepared by: County of Fresno Department of Public Works and Planning GS

µ0 1 2 3 40.5

Miles

MADERA COUNTY

SUBJECT PROPERTY

APN 138-121-11S

APN 138-160-46

CITY OF

CLOVIS

Page 40: STEVEN E. WHITE, DIRECTOR

(c) 2007 AT&T Intellectual Property. All rights reserved. AT&T and the AT&T logo are trademarks of AT&T Intellectual Property.

CVL03147 Zoning Propagation Map

November 07, 2018

Page 41: STEVEN E. WHITE, DIRECTOR

Existing LTE 700 Coverage

November 07, 2018

LegendIn-Building ServiceIn-Transit ServiceOutdoor Service

Proposed site

Existing site

Page 42: STEVEN E. WHITE, DIRECTOR

Proposed LTE 700 Coverage (RC = 50 ft)

LegendIn-Building ServiceIn-Transit ServiceOutdoor Service

Proposed site

Existing site

MILLERTON RD

November 07, 2018

Page 43: STEVEN E. WHITE, DIRECTOR

Version Date: January 10, 2019

Marshall Junction Millerton Rd

Prather, CA 93656 B . CVL03147 ~at&t

©Copyright 2019 Previsualists Inc. • www.photosim.com • Any modification is strict ly prohibited. Printing letter size or larger is permissible. This photosimulation is based upon information provided by the project applicant.

Page 44: STEVEN E. WHITE, DIRECTOR

Photosimulation of the view looking west from Millerton Road.

Proposed tree pole

- ·----

Version Date: January 10, 2019

Millerton Rd Prather, CA 93656

B , CVL03147 ~at&t

©Copyright 2019 Previsualists Inc. • www.photosim.com • Any modification is strict ly prohibited. Printing letter size or larger is permissible. This photosimulation is based upon information provided by the project applicant.

Page 45: STEVEN E. WHITE, DIRECTOR

Photosimulation of the view looking south from Oak Creek Road.

Proposed tree pole~

Version Date: January 10, 2019

Marshall Junction Millerton Rd

Prather, CA 93656 B , CVL03147 ~at&t

©Copyright 2019 Previsualists Inc. • www.photosim.com • Any modification is strict ly prohibited. Printing letter size or larger is permissible. This photosimulation is based upon information provided by the project applicant.

Page 46: STEVEN E. WHITE, DIRECTOR

Version Date: January 10, 2019 ,--~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~---..,=

Photosimulation of the view looking west from the intersection of Millerton Rd and Morgan Canyon.

Proposed tree pole

Millerton Rd Prather, CA 93656

B , CVL03147 ~at&t

©Copyright 2019 Previsualists Inc. • www.photosim.com • Any modification is strict ly prohibited. Printing letter size or larger is permissible. This photosimulation is based upon information provided by the project applicant.

Page 47: STEVEN E. WHITE, DIRECTOR

Photosimulation of the view looking southwest from the clearest view along Morgan Canyon Road. 71-:7f'i:.~·

Version Date: January 10, 2019 ~,_,.,..--,.,,.---...,,,

Marshall Junction Millerton Rd

Prather, CA 93656 CVL03147

©Copyright 2019 Previsualists Inc. • www.photosim.com • Any modification is strict ly prohibited. Printing letter size or larger is permissible. This photosimulation is based upon information provided by the project applicant.

Page 48: STEVEN E. WHITE, DIRECTOR

Photosimulation of the view looking southeast from Millerton Road, approaching the area.

Proposed tree pole, not visible, beyond this hill

Version Date: January 10, 2019

Millerton Rd Prather, CA 93656

B , CVL03147 ~at&t

©Copyright 2019 Previsualists Inc. • www.photosim.com • Any modification is strictly prohibited. Printing letter size or larger is permissible. This photosimulation is based upon information provided by the project applicant.