superior blowing solutions - emtelle
TRANSCRIPT
catalogue 2020
SUPERIOR BLOWING SOLUTIONSand all types of optical cable
About Emcab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Emcab facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
First-class production . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
First-class materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
First-class quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
ABC Configurator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Your benefits of choosing Emcab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Superior microducts from Emtelle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Emcab optical cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Blowing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Ducting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Direct Buried . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Submarine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
ADSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Indoor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
OPGW/Ground Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Fire Rated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Technical information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110
2
About Emcab
EMTELLE is a leading global manufacturer
of pre-connectorised, blown fiber cable,
and ducted network solutions . With
manufacturing operations in UK, Germany
and Denmark, as well as sales offices
internationally, Emtelle serves over 100
countries globally to multiple sectors
including telecommunications and power .
Find out more: www.emtelle.com
INCAB is a leading worldwide optical cable
manufacturer, with production facilities
in Russia and in the USA, covering all
applications of optical cables, including
telecommunication, power utilities and
specialty .
Find out more: www.incab.co,
www.incabamerica.com
EMCAB is a joint venture between EMTELLE and INCAB, located in the heart of Europe:
Erfurt, Germany .
Now, those two industry leaders join forces by combining their expertise, energy and
innovation power to deliver full fiber cable solutions to customers through EMCAB .
EMCAB cables are certified to use with EMTELLE ducts .
Together Emcab cables and Emtelle microduct solutions cover all customer needs .
3
Emcab facilities
Sønder Felding, Denmark Perm,
Russia
Hawick, Scotland
Arlington, TX, the USA
Erfurt, Germany
Production sites Blowing tracks
First-class production4 production sites
5
6
First-class materialsCORNING® fiber is in the heart of Emcab’s cables .
7
8
First-class qualityStep-by-step control
quality control of incoming materials
measuring parameters of each optical fiber
fiber length control in tubes
conformity check of design
check of resistance and tightness of the jacket (for armored cables)
control of marking and packaging
1 3
2 4 6
5
9
We carry out all the necessary test types at our own test center:
• Electrical test
(electrical resistance of circuit “armor – ground
(water)”, leakage current)
• Temperature tests (temperature cycling, cooling, heating)
• Mechanical tests (tensile performance, repeated bending, crush,torsion,
impact)
• Water penetration
• Testing of optical cable & OPGW for power transmission lines & fiber optic lines - Monitoring of icing occurrence
- Temperature monitoring of power transmission lines
- Detection of lightning stroke points based on system
of distributed monitoring of acoustic signal
10
First-class qualityEmcabs air blown cables undergo regular approval tests at our regional test tracks using our latest Manufacturing & Design Technology .
Watch the blowing test
11
Our blowing tracks are customer specific and conform to IEC 60794-1-21:2015 Standard:
Hawick, Perm, Sonder Felding
Test site characteristics:
• Route length up to 2000 m
• Cable diameter range: 2 .5–16 mm
Erfurt
• Coming soon
12
ABC ConfiguratorAir Blown Cables (ABC) Configurator is a unique software tool designed for automatic selection of the package solution for blowing technology . Select necessary parameters and it will help you choose the optimal solution to your requirements: applicable cable design, suitable tube and closure . As easy as ABC!
• cable application• fiber count and size• jacket type• cable diameter• tube size
1. Select necessary characteristics:
13
2. Get:
• cable that meets your requirements and datasheet for it• suitable tube diameter and datasheet for it• cable installation tips• range of suitable closures with datasheet for them
Use our free software to selectthe complete package for blowing technology
14
Your benefits of choosing Emcab
experience of two global manufacturers to create a quality product . You get the complete solution package
delivery of cables with superior test performance . You can be sure of quality
the most popular designs in stock . You save time
4 production sites . You get your orders efficiently
history of Emcab in 30 seconds! #followemcab
15
Superior microducts from Emtelle Microducts need to be made for their intended environment . Emtelle doesn’t just turn a material into a tube . The technology behind simplicity is the key to embrace the cable .
Ducts configuration
24-way:
7-way: 8-way:
12-way: 14-way: 19-way: 24-way HEX:
1-way: 2-way: 3-way:
5-way: 6-way:
4-way:
emtelle .com
16
Emtelle facilities
17
18
Emcab optical cables
Blowing Ducting Direct Buried Submarine ADSS
Indoor Drop Fire RatedOPGW/Ground Wire
19
Blowing
Emcab cables are rigid yet flexible enough to be installed into tubes and include many options for installation by blowing .
Operation parameters
Operation temperature -45°С…+70°С
Installation temperature -30°С…+50°С
Transportation and storage temperature -60°С…+70°С
Minimum bending radius 15×cable diameters
Life time 25 years
Options
Jacket — polyethylene or polyamide
Fiber — G .652D + G .657 .A1 (200 μm or 250 μm)
Discover detailed technical parameters for each design at emcab .co Read more at page 10
Each and all blowing cables are tested according toIEC 60794-1-21:2015 Standard
Blowing distance 2000m . Performance confirmed
Discover more
21
Blo
win
g
Blowing CT
1234
Cable design
1 . Optical fiber
2 . Compact fiber unit
3 . Aramid yarns
4 . Jacket
Features
Cables are tested according to IEC 60794-1-21:2015
Blowing track: 2000 m . Performance confirmed
Reduced weight and size . Convenient for micro ducts
Parameters• Up to 24 fibers
• Cable diameter from 2 .0 mm
• Operation tension up to 300 N
• Installation tension up to 440 N
FiberFlow
Suitable microduct size up to 8/5
Central tube (CT) design for blowing .
Select the complete package for blowing technology
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
22
Blo
win
g
Blowing MT 12
Cable design
1 . Central strength member (FRP rod)
2 . Optical fiber
3 . Gel-filled loose tube
4 . Water-swellable yarns
5 . Jacket
Features Parameters• Up to 432 fibers
• 12 fibers per tube
• Cable diameter from 3 .6 mm
• Operation tension up to 1 kN
• Installation tension up to 3 kN
Jacket — polyethylene or polyamide
Fiber — G .652D + G .657 .A1 (200 μm or 250 μm)
123
45
FiberFlow
Suitable microduct size up to 10/6
Multi-tube (MT) design with 12 fibers per tube for blowing .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Cables are tested according to IEC 60794-1-21:2015
Blowing track: 2000 m . Performance confirmed
Select the complete package for blowing technology
23
Blo
win
g
Blowing MT 24
Cable design
1 . Central strength member (FRP rod)
2 . Optical fiber
3 . Gel-filled loose tube
4 . Water-swellable yarns
5 . Jacket
Features Parameters• Up to 288 fibers
• 24 fibers per tube
• Cable diameter from 5 .3 mm
• Operation tension up to 1 kN
• Installation tension up to 3 kN
Easy to install
123
45
FiberFlow
Suitable microduct size up to 10/8
Multi-tube (MT) design with 24 fibers per tube for blowing .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Cables are tested according to IEC 60794-1-21:2015
Blowing track: 2000 m . Performance confirmed
Select the complete package for blowing technology
DuctingOptical cables for duct and utility tunnels include dielectric and metallic designs .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specifications .
Operation parameters
Operation temperature -50°С…+70°С
Installation temperature -30°С…+50°С
Transportation and storage temperature -50°С…+70°С
Minimum bending radius 15×cable diameter
Life time 25 years
Discover more
25
Du
cti
ng
Easy strippable tubes
The most popular design
Ducting MT FiberGlass Soft Tubes
Cable design
1 . Optical fiber
2 . Gel-filled soft tube
3 . Water-swellable yarns
4 . Fibersglass yarns
5 . FRP rod
6 . Jacket
Parameters• Up to 432 fibers
• Operation tension up to 1 .2 kN
• Installation tension up to 1 .5 kN
All-dielectric design
Suitable for aerial application
123
4
5
5
6
Features
Multi-tube (MT) fibreglass soft tube design for ducts and utility tunnels .
Сlick here to see detailed features of this design
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
26
Du
cti
ng
Ducting MT HFC 432
Cable design
1 . Central strength member (FRP rod)
2 . 3 layers of gel-filled loose tubes
of optical fibers
3 . Water-swellable yarns under each loose
tube’s layer
4 . Water-swellable tape under stranded core
5 . Ripcord
6 . Jacket
Parameters• Up to 432 fibers
• Max rated design tension up to 0 .7 kN
• Crush – 0 .1 kN /cm
Features
Easy to installAll-dielectric design
12456
3
Multi-tube (MT) design with fiber count (HFC) increased up to 432 for ducts and utility tunnels .
High fiber count
Сlick here to see detailed features of this design
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
27
Du
cti
ng
Easy to install
Ducting MT HFC 864
Cable design
1 . Central strength member (FRP rod)
2 . 3 layers of gel-filled loose tubes
of optical fibers
3 . Water-swellable yarns under each loose
tube’s layer
4 . 3 layers of water-swellable tape under
stranded core
5 . Fiberglass yarns
6 . Ripcord
7 . Jacket
Parameters• Up to 864 fibers
• Max rated design tension up to 4 kN
• Crush – 0 .3 kN /cm
All-dielectric design
Features
124
6
573
Multi-tube (MT) fiberglass yarn design with fiber count (HFC) increased up to 864 for ducts and utility tunnels .
High fiber count
Сlick here to see detailed features of this design
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
28
Du
cti
ng
All-dielectric design
Ducting MT Aramid
Cable design
1 . Central strength member (FRP rod)
2 . Optical fiber
3 . Gel-filled loose tube
4 . Water-swellable yarns
5 . Aramid yarns
6 . Jacket
Parameters• Up to 432 fibers
• Max rated design tension up to 1 .5 kN
• Crush – 0 .3 kN /cmEasy to install
Features
Reduced weight and size
1
2456 3
Multi-tube (MT) aramid design for extra axial pulling strength applied in ducts and utility tunnels .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
29
Du
cti
ng
Easy to install
Ducting MT FiberGlass
Cable design
1 . Central strength member (FRP rod)
2 . Optical fiber
3 . Gel-filled loose tube
4 . Water-swellable yarns
5 . Fiberglass yarns
6 . Jacket
Parameters• Up to 432 fibers
• Max rated design tension up to 2 .7 kN
• Crush – 0 .3 kN /cm
All-dielectric design
Reduced weight and size
Features
1
2
456 3
Multi-tube (MT) fiberglass yarn design for extra axial pulling strength applied in ducts and utility tunnels .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
30
Du
cti
ng
All-dielectric design
Ducting MT FiberGlass DJ
Cable design
1 . Central strength member (FRP rod)
2 . Optical fiber
3 . Gel-filled loose tube
4 . Water-blocking gel
5 . Inner jacket
6 . Fiberglass yarns
7 . Jacket
Parameters• Up to 432 fibers
• Max rated design tension up to 2 .7 kN
• Crush – 0 .3 kN /cm
Fiberglass yarns prevent damage by rodents
Features
34567 12
Multi-tube (MT) fiberglass yarn double jacket (DJ) design for extra axial pulling strength applied in ducts and utility tunnels .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
31
Du
cti
ng
Excellent rodent resistance
Ducting CT CST Light
Cable design
1 . Optical fiber
2 . Gel-filled loose tube
3 . Water-blocking gel
4 . Corrugated steel tape armor
5 . Steel wires
6 . Jacket
Parameters• Up to 24 fibers
• Max rated design tension up to 2 .7 kN
• Crush – 0 .5 kN /cmCost-effective design
Reduced weight and size
Features
346
5
5
12
Central tube (CT) corrugated steel tape (CST) design for ducts and utility tunnels .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
The most popular design
Сlick here to see detailed features of this design
32
Du
cti
ng
Ducting MT CST Light
Cable design
1 . Optical fiber
2 . Gel-filled loose tube
3 . Water-blocking gel
4 . Corrugated steel tape armor
5 . Steel wires
6 . Jacket
Parameters• Up to 48 fibers
• Max rated design tension up to 2 .7 kN
• Crush – 0 .3 kN /cmExcellent rodent resistance
Cost-effective design
Reduced weight and size
Features
346
5
12
Multi-tube (MT) corrugated steel tape (CST) design for ducts and utility tunnels .
The most popular design
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
33
Du
cti
ng
Excellent rodent resistance
Increased tightness due to application of water-swellable tape
Ducting MT CST
Cable design
1 . Central strength member (FRP rod)
2 . Water-swellable yarns
3 . Optical fiber
4 . Gel-filled loose tube
5 . Water-swellable tape
6 . Corrugated steel tape armor
7 . Jacket
Parameters• Up to 432 fibers
• Max rated design tension up to 2 .7 kN
• Crush – 0 .3 kN /cmCost-effective design
Reduced weight and size
Features
1234 27 56
Multi-tube (MT) corrugated steel tape (CST) design for ducts and utility tunnels .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
34
Du
cti
ng
Ducting MT CST DJ
Cable design
1 . Central strength member (FRP rod)
2 . Optical fiber
3 . Gel-filled loose tube
4 . Water-blocking gel
5 . Inner jacket
6 . Water-swellable yarns
7 . Corrugated steel tape armor
8 . Jacket
Parameters• Up to 432 fibers
• Max rated design tension up to 2 .7 kN
• Crush – 0 .3 kN /cmExcellent rodent resistance
Improved reliability due to inner jacketing
Features
12
3458 76
Multi-tube (MT) corrugated steel tape (CST) double jacket (DJ) design for ducts and utility tunnels .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
35
Du
cti
ng
Excellent rodent resistance
Ducting SST
Cable design
1 . Optical fiber
2 . Steel tube
3 . Jacket
Parameters• Up to 96 fibers
• Max rated design tension up to 1 .5 kN
• Crush – 0 .7 kN /cmThe smallest diameter
100% waterproof
Features
3 12
Stainless steel tube (SST) design for ducting .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
36
Du
cti
ng
Ducting CT GSW
Cable design
1 . Optical fiber
2 . Gel-filled loose tube
3 . Water-blocking gel
4 . Armor of galvanized steel wires
5 . Jacket
Parameters• Up to 24 fibers
• Max rated design tension up to 7 kN
• Crush – 0 .7 kN /cmExcellent rodent resistance
Features
100% waterproof
Cost-effective design
Reduced weight and size
345 12
Central tube (CT) galvanized steel wires (GSW) design for additional protection applied in ducts and utility tunnels .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
38
Du
cti
ng
Direct BuriedFiber optic cables designed for high reliability in harsh environment .
Operation parameters
Operation temperature -50°С…+70°С
Installation temperature -30°С…+50°С
Transportation and storage temperature -50°С…+70°С
Minimum bending radius 15×cable diameter
Life time 25 years
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specifications .
Discover more
39
Dir
ec
t B
uri
ed
Direct Buried CT CST Light
Excellent rodent resistance
Cable design
1 . Optical fiber
2 . Gel-filled loose tube
3 . Water-blocking gel
4 . Corrugated steel tape armor
5 . Steel wires
6 . Jacket
Parameters• Up to 24 fibers
• Max rated design tension up to 2 .7 kN
• Crush – 0 .5 kN /cmCost-effective design
Reduced weight and size
Features
346
5
5
12
Central tube (CT) corrugated steel tape (CST) design for direct buried .
Сlick here to see detailed features of this design
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
40
Dir
ec
t B
uri
ed
Direct Buried MT CST Light
Cable design
1 . Optical fiber
2 . Gel-filled loose tube
3 . Water-blocking gel
4 . Corrugated steel tape armor
5 . Steel wires
6 . Jacket
Parameters• Up to 48 fibers
• Max rated design tension up to 2 .7 kN
• Crush – 0 .3 kN /cmExcellent rodent resistance
Cost-effective design
Reduced weight and size
Features
346
5
5
12
Multi-tube (MT) corrugated steel tape (CST) design for direct buried .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
41
Dir
ec
t B
uri
ed
Direct Buried MT CST
Excellent rodent resistance
Increased tightness due to application of water-swellable tape
Cable design
1 . Central strength member (FRP rod)
2 . Water-swellable yarns
3 . Optical fiber
4 . Gel-filled loose tube
5 . Water-swellable tape
6 . Corrugated steel tape armor
7 . Jacket
Parameters• Up to 432 fibers
• Max rated design tension up to 2 .7 kN
• Crush – 0 .3 kN /cmCost-effective design
Reduced weight and size
Features
123247 56
Multi-tube (MT) corrugated steel tape (CST) design for direct buried .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
42
Dir
ec
t B
uri
ed
Direct Buried MT CST DJ
Parameters• Up to 432 fibers
• Max rated design tension up to 2 .7 kN
• Crush – 0 .3 kN /cmExcellent rodent resistance
Improved reliability due to inner jacketing
Features
Multi-tube (MT) corrugated steel tape (CST) double jacket (DJ) design for direct buried .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Cable design
1 . Central strength member (FRP rod)
2 . Optical fiber
3 . Gel-filled loose tube
4 . Water-blocking gel
5 . Inner jacket
6 . Water-swellable yarns
7 . Corrugated steel tape armor
8 . Jacket
12
3458 76
Сlick here to see detailed features of this design
43
Dir
ec
t B
uri
ed
Direct Buried SST
Excellent rodent resistance
Cable design
1 . Optical fiber
2 . Steel tube
3 . Jacket
Parameters• Up to 96 fibers
• Max rated design tension up to 1 .5 kN
• Crush – 0 .7 kN /cmThe smallest diameter
100% waterproof
Features
3 12
Stainless steel tube (SST) design for direct buried .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
44
Dir
ec
t B
uri
ed
Direct Buried CT FRP
Cable design
1 . Optical fiber
2 . Gel-filled loose tube
3 . Water-blocking gel
4 . Fiberglass rods
5 . Jacket
Parameters• Up to 24 fibers
• Max rated design tension up to 12 kN
• Crush – 0 .7 kN /cm
Features
12345
Excellent rodent resistance
All-dielectric design
Reliable protection from serious mechanical impact
Reduced weight and size
Central tube (CT) fiberglass rods (FRP) design for additional protection in harsh environment .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
45
Dir
ec
t B
uri
ed
Direct Buried CT FRP2
Cable design
1 . Optical fiber
2 . Gel-filled loose tube
3 . Water-blocking gel
4 . Double armor of fiberglass rods
5 . Jacket
Parameters• Up to 24 fibers
• Max rated design tension up to 30 kN
• Crush – 1 kN /cm
Features
All-dielectric design
Suitable for application in harsh environments
Reduced weight and size
12345
Central tube (CT) fiberglass rods (FRP) double armor design for additional protection in harsh environment .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
46
Dir
ec
t B
uri
ed
Direct Buried MT FRP
Cable design
1 . Central strength member (FRP rod)
2 . Optical fiber
3 . Gel-filled loose tube
4 . Water-blocking gel
5 . Inner jacket
6 . Fiberglass rods
7 . Jacket
Parameters• Up to 432 fibers
• Max rated design tension up to 20 kN
• Crush – 0 .4 kN /cm
Features
12
354 467
Excellent rodent resistance
All-dielectric design
Reliable protection from serious mechanical impact
Multi-tube (MT) fiberglass rods (FRP) double jacket design for additional protection in harsh environment .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
47
Dir
ec
t B
uri
ed
Direct Buried MT FRP2
Cable design
1 . Central strength member (FRP rod)
2 . Optical fiber
3 . Gel-filled loose tube
4 . Water-blocking gel
5 . Inner jacket
6 . Double armor of fiberglass rods
7 . Jacket
Parameters• Up to 432 fibers
• Max rated design tension up to 40 kN
• Crush – 1 kN /cm
Features
All-dielectric design
Excellent rodent resistance
Applied in harsh environments with potential mechanical impact: in all ground types, swamps and harsh rivers
12
344 567
Multi-tube (MT) fiberglass rods (FRP) double armor double jacket design for additional protection in harsh environment .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
48
Dir
ec
t B
uri
ed
Direct Buried SST GSW
Cable design
1 . Optical fiber
2 . Gel-filled stainless steel tube
3 . Armor of galvanized steel wires
4 . Jacket
Parameters• Up to 96 fibers
• Max rated design tension up to 10 kN
• Crush – 1 kN /cm
Features
1234
100% waterproof
Certified as CPR compliant Euroclass Dca
Excellent rodent resistance
Stainless steel tube (SST) galvanized steel wires (GSW) design for additional protection in harsh environment .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
49
Dir
ec
t B
uri
ed
Direct Buried CT GSW
Cable design
1 . Optical fiber
2 . Gel-filled loose tube
3 . Water-blocking gel
4 . Armor of galvanized steel wires
5 . Jacket
Parameters• Up to 24 fibers
• Max rated design tension up to 7 kN
• Crush – 0 .7 kN /cmExcellent rodent resistance
Features
100% waterproof
Cost-effective design
Reduced weight and size
345 12
Central tube (CT) galvanized steel wires (GSW) design for additional protection in harsh environment .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
50
Dir
ec
t B
uri
ed
Direct Buried CT GSW2
Cable design
1 . Optical fiber
2 . Gel-filled loose tube
3 . Water-blocking gel
4 . Double armor of galvanized steel wires
5 . Jacket
Parameters• Up to 24 fibers
• Max rated design tension up to 50 kN
• Crush – 1 kN /cm
Features
1235 4
Excellent rodent resistance
Suitable for harsh environment applications
Central tube (CT) galvanized steel wires (GSW) double armor design for additional protection in harsh environment .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
51
Dir
ec
t B
uri
ed
Direct Buried MT GSW
Cable design
1 . Central strength member (FRP rod)
2 . Optical fiber
3 . Gel-filled loose tube
4 . Water-blocking gel
5 . Inner jacket
6 . Armor of galvanized steel wires
7 . Jacket
Parameters• Up to 432 fibers
• Max rated design tension up to 80 kN
• Crush – 1 kN /cm
Features
Reliable protection from serious mechanical impact
344 567 12
Excellent rodent resistance
Multi-tube (MT) galvanized steel wires (GSW) double jacket design for additional protection in harsh environment .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
52
Dir
ec
t B
uri
ed
Direct Buried MT GSW2
Cable design
1 . Central strength member (FRP rod)
2 . Optical fiber
3 . Gel-filled loose tube
4 . Water-blocking gel
5 . Inner jacket
6 . Double armor of galvanized steel wires
7 . Jacket
Parameters• Up to 288 fibers
• Max rated design tension up to 80 kN
• Crush – 1 kN /cm
Features
12
3567 44
Excellent rodent resistance
Applied in harsh environments with potential mechanical impact: in all ground types, swamps and harsh rivers
Multi-tube (MT) galvanized steel wires (GSW) double armor double jacket design for additional protection in harsh environment .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
53
Dir
ec
t B
uri
ed
Direct Buried MT GSW Special
Cable design
1 . Central strength member (FRP rod)
2 . Optical fiber
3 . Gel-filled loose tube
4 . Water-blocking gel
5 . Aluminum polymer jacket
6 . Inner jacket
7 . Armor of galvanized steel wires
8 . Jacket
Parameters• Up to 432 fibers
• Max rated design tension up to 80 kN
• Crush – 0 .4 - 1 kN /cm
Features
344 5678 1
2
Excellent solution for wetland and cross-river installation
Aluminum polymer jacket protects the cable core from moisture
Multi-tube (MT) galvanized steel wires (GSW) special design for additional mechanical protection and moisture barrier in harsh environment .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
54
Dir
ec
t B
uri
ed
Direct Buried MT GSW2 Special
Cable design
1 . Central strength member (FRP rod)
2 . Optical fiber
3 . Gel-filled loose tube
4 . Water-blocking gel
5 . Aluminum polymer jacket
6 . Inner jacket
7 . Double armor of galvanized steel wires
8 . Jacket
Parameters• Up to 288 fibers
• Max rated design tension up to 80 kN
• Crush – 1 kN /cm
Features
12
35678 44
Excellent solution for wetland and cross-river installation
Aluminum polymer jacket protects the cable core from moisture
Suitable for application in harsh environments
Multi-tube (MT) galvanized steel wires (GSW) double armor special design for additional mechanical protection and moisture barrier in harsh environment .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
56
SubmarineRobust designs applied in the sea between land-based stations to carry telecommunication signal .
Operation parameters
Operation temperature -50°С…+70°С
Installation temperature -30°С…+50°С
Transportation and storage temperature -50°С…+70°С
Minimum bending radius 15×cable diameter
Life time 25 years
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specifications .
Discover more
57
Sub
mar
ine
Cable design
1 . Optical fiber
2 . Gel-filled loose tube
3 . Water-blocking gel
4 . Armor of galvanized steel wires
5 . Water-swellable tape
6 . Aluminum polymer jacket
7 . Inner jacket
8 .Jacket
Parameters• Up to 24 fibers
• Max rated design tension up to 70 kN
• Crush – 1 .5 kN /cm
Features
33 44 5678 12
Suitable for application in harsh environments
Installation down to 2500 m
Submarine CT GSW2Central tube (CT) galvanized steel wires (GSW) design applied in the sea between land-based stations to carry telecommunication signals .
Сlick here to see detailed features of this design
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
58
Sub
mar
ine
Cable design
1 . Optical fiber
2 . Gel-filled steel tube
3 . Water-blocking gel
4 . Armor of galvanized steel wires
5 . Water-swellable tape
6 . Aluminum polymer jacket
7 . Inner jacket
8 . Jacket
Parameters• Up to 96 fibers
• Max rated design tension up to 85 kN
• Crush – 1 .5 kN /cm
Features
33 44 5678 12
Suitable for application in harsh environments
Installation down to 5000 m
Submarine SST GSW2Stainless steel tube (SST) galvanized steel wires (GSW) design applied in the sea between land-based stations to carry telecommunication signals .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
59
60
AD
SS
ADSSAll-Dielectric Self-Supporting cables .
Operation parameters
Operation temperature -50°С…+70°С
Installation temperature -30°С…+50°С
Transportation and storage temperature -50°С…+70°С
Minimum bending radius 15×cable diameter
Life time 25 years
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specifications .
Discover more
61
AD
SS
Cable design
1 . Optical fiber
2 . Gel-filled soft tube
3 . Water-swellable yarns
4 . Fibersglass yarns
5 . FRP rod
6 . Jacket
Parameters• Up to 432 fibers
• Operation tension up to 1 .2 kN
• Installation tension up to 1 .5 kN
ADSS FiberGlass Soft Tubes
Easy strippable tubes
Features
All-dielectric design
Suitable for aerial application
123
4
5
5
6
Features
Easy strippable design for aerial installation up to 50 m .
Сlick here to see detailed features of this design
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
62
AD
SS
Cable design
1 . Optical fiber
2 . Gel-filled loose tube
3 . FRP rod
4 . Jacket
Parameters• Up to 24 fibers
• Max rated design tension up to 2 .2 kN
• Crush – 1 .4 kN /cm
ADSS Flat Type Micro
High crush resistance
Reduced weight and size
All-dielectric design
Applied as ‘the last mile’ in cottage villages
Cost-effective design
12
3
3
4
Features
Flat design for aerial installation: on power lines, lamp posts, between buildings and constructions . Suitable for aerial installation on transmission equipment and power facilities in dielectric package .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
63
AD
SS
Cable design
1 . Central strength member (FRP rod)
2 . Optical fiber
3 . Gel-filled loose tube
4 . Water-blocking gel
5 . Inner jacket
6 . Fiberglass rods
7 . Jacket
Parameters• Up to 432 fibers
• Max rated design tension up to 20 kN
• Crush – 0 .4 kN /cm
ADSS Defender
Completely protected from water ingress . Anti-rodent additive in the outer jacket for first-line protection
Superior protection from mechanical damage — FRP rods provide strength and second-line protection
12
344 567
Features
Anti-rodent robust design for aerial installation .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
64
AD
SS
Cable design
1 . Central strength member (FRP rod)
2 . Optical fiber
3 . Gel-filled loose tube
4 . Water-swellable yarns
5 . Aramid yarns
6 . Jacket
Parameters• Up to 432 fibers
• Max rated design tension up to 10 kN
• Crush – 0 .3 kN /cm
ADSS Aramid
Wide range of operating temperatures . Installation temperature down to -30°C
Reduced weight and size
Aerial installation on distribution and transmission lines up to 35 kV
Low susceptibility to ice and wind loads
Application up to 10 kN with span lengths up to 200 meters
1
2
34
56
Features
Aramid design for aerial installation on transmission towers, high-voltage power lines and railway catenary; highly resistant to electromagnetic effect .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
65
AD
SS
Cable design
1 . Central strength member (FRP rod)
2 . Optical fiber
3 . Gel-filled loose tube
4 . Water-blocking gel
5 . Inner jacket
6 . Aramid yarns
7 . Jacket
Parameters• Up to 432 fibers
• Max rated design tension up to 100 kN
• Crush – 0 .3 kN /cm
ADSS Aramid DJ
Wide range of operating temperatures . Installation temperature down to -30°C
For construction of communication lines between towns and cities with distances between towers reaching 500 meters
Aerial installation on distribution and transmission lines up to 138 kV and above with tracking-resistant jacket
Max rated design tension up to 100 kN
The most reliable among ADSS cables . Double tensile strength
12
3567 4
Features
Aramid double jacket (DJ) design for aerial installation on transmission towers, high-voltage power lines and railway catenary; highly resistant to electromagnetic effect .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
66
AD
SS
Cable design
1 . Central strength member (FRP rod)
2 . Optical fiber
3 . Gel-filled loose tube
4 . Water-swellable yarns
5 . Fiberglass yarns
6 . Jacket
Parameters• Up to 432 fibers
• Max rated design tension up to 10 kN
• Crush – 0 .3 kN /cm
ADSS FiberGlass
Wide range of operating temperatures . Installation temperature down to -30°C
Reduced weight and size
Aerial Installation on distribution and transmission lines up to 35 kV
Low susceptibility to ice and wind loads
Application up to 10 kN with span lengths up to 200 meters
1
2
34
56
Features
Fiberglass yarns design for aerial installation on transmission towers, high-voltage power lines and railway catenary; highly resistant to electromagnetic effect .
Сlick here to see detailed features of this design
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
67
AD
SS
Cable design
1 . Central strength member (FRP rod)
2 . Optical fiber
3 . Gel-filled loose tube
4 . Water-blocking gel
5 . Inner jacket
6 . Fiberglass yarns
7 . Jacket
Parameters• Up to 432 fibers
• Max rated design tension up to 15 kN
• Crush – 0 .3 kN /cm
ADSS FiberGlass DJ
Wide range of operating temperatures . Installation temperature down to -30°C
Aerial installation on distribution and transmission lines up to 138 kV and above with tracking-resistant jacket
Max rated design tension up to 15 kN with span lengths up to 300 meters
Cost-effective solution for city trunk lines
12
3567 4
Features
Fiberglass yarns double jacket (DJ) design for aerial installation on transmission towers, high-voltage power lines and railway catenary; highly resistant to electromagnetic effect .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
68
Ind
oo
r
IndoorApplied inside buildings (including vertical runs), in trays, channels, on outer sides of buildings, as well as in ducts, tubes and blocks . Suitable for blowing into protecting polyethylene tubes .
Operation parameters
Operation temperature -30°С…+50°С
Installation temperature -10°С…+50°С
Transportation and storage temperature -50°С…+50°С
Minimum bending radius 10×cable diameter
Life time 25 years
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specifications .
Discover more
69
Ind
oo
r
Cable design
1 . Optical fiber
2 . Tight-buffer
3 . FRP rod
4 . Halogen-free flame-retardant jacket
5 . Match marks (jacket opening marking)
Parameters• Up to 48 fibers
• Max rated design tension up to 400 N
• Crush – 80 N /c
Riser TB
12
3
3
5
4
Perfect solution for high buildings: the fiber is buffered up to floor box or up to the subscriber’s flat
Features
Easy access to the fiber at any place of the cable
UV-resistant
Certified as CPR compliant Euroclass Dca
Operation temperature range down to -30°C
Flame-retardant
All-dielectric design
Riser tight-buffered (TB) is applied inside buildings (including vertical runs), in trays, channels, on outer sides of buildings, as well as in ducts, tubes and blocks . Suitable for blowing into protecting polyethylene tubes .
Сlick here to see detailed features of this design
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
70
Ind
oo
r
Cable design
1 . Optical fiber
2 . Tight-buffer
3 . Aramid yarns
4 . Halogen-free flame-retardant jacket
1234
Features
UV-resistant
Flame-retardant
Easy termination
All-dielectric design
Perfect solution for offices and data centers
More flexible compared to the Riser Cable
Distribution TB
Parameters• Up to 48 fibers
• Operation tension up to 800 N
• Installation tension up to 1600 N
• Crush up to 0 .2 kN/cm
Distribution tight-buffered (TB) is applied inside buildings (including vertical runs), in trays, channels, on outer sides of buildings, as well as in ducts, tubes and blocks . Suitable for blowing into protecting polyethylene tubes .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
71
Ind
oo
r
12
3
3
45
Features
UV-resistant
Certified as CPR compliant Euroclass Dca
Perfect solution for multi-dwelling units
High density of fibers makes it possible to bundle up to 24 fibers into micro loose tubes and place up to 48 micro loose tubes in a cable
Operation temperature down to -30°C
Easy access to fiber at any place of the cable
Flame-retardant
All-dielectric design
Riser MT
Cable design
1 . Optical fiber
2 . Micro tubes
3 . FRP rod
4 . Halogen-free flame-retardant jacket
5 . Match marks (jacket opening marking)
Parameters• Up to 1152 fibers
• Max rated design tension up to 400 N
• Crush – 80 N /cm
Riser micro tube (MT) is applied inside buildings (including vertical runs), in trays, channels, on outer sides of buildings, as well as in ducts, tubes and blocks . Suitable for blowing into protecting polyethylene tubes .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
72
Ind
oo
r
Cable design
1 . Optical fiber
2 . Micro tubes
3 . Aramid yarns
4 . Halogen-free flame-retardant jacket
Parameters• Up to 288 fibers
• Operation tension up to 800 N
• Installation tension up to 1600 N
• Crush - 0 .1 kN/cm
Distribution MT
1234
Features
UV-resistantHigh density of fibers makes it possible to bundle up to 24 fibers into micro loose tubes and place up to 48 micro loose tubes in a cable
Flame-retardantAll-dielectric design
Distribution micro tube (MT) is applied inside buildings (including vertical runs), in trays, channels, on outer sides of buildings, as well as in ducts, tubes and blocks . Suitable for blowing into protecting polyethylene tubes .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
73
Ind
oo
r
Cable design
1 . Optical fiber
2 . Tight-buffer
3 . Fiberglass yarns
4 . Inner jacket made of halogen-free flame-
retardant polymer compound
5 . Mica glass tape
6 . Halogen-free jacket
Parameters• Up to 24 fibers
• Max rated design tension up to 1 .1 kN
• Crush — 0 .2 kN/cm
Distribution Fire Rated
1233 456
Easy to install
Features
UV-resistant
Remains functional under direct flame for at least 180 minutes
All-dielectric design
Tight-buffered double jacket design for individual installation in cable structures and working spaces .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
74
Ind
oo
r
Cable design
1 . Optical fiber
2 . Tight-buffer
3 . Aramid yarns
4 . Halogen-free flame-retardant jacket
Parameters• Max rated design tension 0 .180 kN
• Crush — 0 .05 kN/cm
Simplex
1234
Features
UV-resistant
Perfect solution for patch cords manufacturing
Cable can be terminated with a standard connector
Compact and flexible
Flame-retardantAll-dielectric design
Applied inside buildings, in trays, cable channels, in duct, tubes and blocks . It is also applied on outer sides of buildings and for patch cords manufacturing .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
75
Ind
oo
r
Features
UV-resistant
Perfect solution for patch cords manufacturing
Cable can be terminated with a standard connector
Compact and flexible
Flame-retardantAll-dielectric design
Cable design
1 . Optical fiber
2 . Tight-buffer
3 . Aramid yarns
4 . Halogen-free flame-retardant jacket
Parameters• Max rated design tension 0 .180 kN
• Crush — 0 .05 kN/cm
Duplex
1
1
2
2
3
3
4
Applied for installation inside buildings, in trays, channels, for patch cords manufacturing .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
76
Dro
p
DropDesigned for aerial installation on transmission towers, lamp posts, between buildings and structures .
Operation parameters
Operation temperature -50°С…+70°С
Installation temperature -30°С…+50°С
Transportation and storage temperature -50°С…+70°С
Minimum bending radius 15×cable diameter
Life time 25 years
We design cables based on our Customers' specific technical Requirements . Please, contact us for a cable designed to your exact specifications .
Discover more
77
Dro
p
Features
Suitable for aerial installation up to 100 meters
Exceedingly high crush resistance
All-dielectric design
Cable design
1 . Optical fiber
2 . Gel-filled loose tube
3 . FRP rod
4 . Jacket
Parameters• Up to 24 fibers
• Max rated design tension 2 .2 kN
• Crush — 1 .4 kN/cm
Flat Type Drop Reinforced
12
3
3
4
Applied for aerial installation on transmission towers, lamp posts, between buildings and constructions .
Сlick here to see detailed features of this design
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
78
Dro
p
Features
Operation temperature range down to -50°С
Reduced weight and size
All-dielectric design
Cable design
1 . Optical fiber
2 . Gel-filled loose tube
3 . Ripcord
4 . FRP rod
5 . Jacket
Parameters• Up to 8 fibers
• Max rated design tension 0 .7 kN
• Crush — 1 kN/cm
Flat Type Drop
123
5
4
4
Applied for aerial installation on transmission towers, lamp posts, between buildings and constructions .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
79
Dro
p
Features
Cost-effective design
Reduced weight and size
All-dielectric design
Cable design
1 . Optical fiber
2 . Tight-buffer
3 . Water-swellable yarns
4 . PBT loose tube
5 . Aramid yarns
6 . Jacket
Parameters• Max rated design tension 1 kN
• Crush — 0 .3 kN/cm
Round Type Drop Tight-buffered
12346 5
Applied for aerial installation on transmission towers, lamp posts, between buildings and constructions .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
80
Dro
p
Features
Reduced weight and size
All-dielectric design
Cable design
1 . Optical fiber
2 . Gel-filled loose tube
3 . Aramid yarns
4 . Jacket
Parameters• Up to 24 fibers
• Max rated design tension up to 2 kN
• Crush — 130 N/cm
Round Type Drop
1234
Cost-effective design
Applied for aerial installation on transmission towers, lamp posts, between buildings and constructions .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
81
Dro
p
82
OP
GW
/Gro
un
d W
ire
OPGW / Ground WireApplied in the construction of fiber-optic link on overhead transmission lines of 35 kV and more .
Operation parameters
Operation temperature -50°С…+85°С
Installation temperature -30°С…+50°С
Transportation and storage temperature -50°С…+70°С
Minimum bending radius 20×cable diameter
Life time 50 years
We design cables based on our Customers' specific technical Requirements . Please, contact us for a cable designed to your exact specifications .
Discover more
83
OP
GW
/Gro
un
d W
ire
Features
Aluminum alloy wires shield the high-voltage conductors from lightning strikes
Aluminum-clad steel wires are corrosion resistant
Cable design
1 . Optical fiber
2 . Gel-filled stainless steel tube
3 . Stranded wires (Aluminum-clad steel wires
and /or aluminum alloy wires)
4 . Stranded wires (Aluminum-clad steel wires
and /or aluminum alloy wires)
Parameters• Up to 96 fibers
• Rated breaking strength up to 210 kN
• Max rated design tension up to 125 kN
• Crush - 1 kN/cm
OPGW C
1234
Protection of power lines from lightning overvoltage, construction of optical communication systems .
Сlick here to see detailed features of this design
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
84
OP
GW
/Gro
un
d W
ire
Features
Aluminum alloy wires shield the high-voltage conductors from lightning strikes
Highly corrosion-resistant: ACS wires and aluminum-clad stainless steel tube
Cable design
1 . Optical fiber
2 . Aluminum-clad stainless steel tube filled
with water-blocking gel
3 . Stranded wires (Aluminum-clad steel wires
and /or aluminum alloy wires)
Parameters• Up to 96 fibers
• Rated breaking strength up to 210 kN
• Max rated design tension up to 125 kN
• Crush – 1 .5 kN/cm
OPGW CA
123
Protection of power lines from lightning overvoltage, construction of optical communication systems .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
85
OP
GW
/Gro
un
d W
ire
Features
Aluminum alloy wires shield the high-voltage conductors from lightning strikes
Aluminum-clad steel wires are corrosion resistant
Cable design
1 . Central strength member (aluminum-clad
steel wires or aluminum alloy wires)
2 . Optical fiber
3 . Stainless steel tube filled with water-
blocking gel
4 . Stranded wires (Aluminum-clad steel wires
and /or aluminum alloy wires)
5 . Stranded wires (Aluminum-clad steel wires
and /or aluminum alloy wires)
Parameters• Up to 432 fibers
• Rated breaking strength up to 275 kN
• Max rated design tension up to 165 kN
• Crush – 1 kN/cm
OPGW S
12
345
Protection of power lines from lightning overvoltage, construction of optical communication systems .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
86
OP
GW
/Gro
un
d W
ire
Features
Aluminum alloy wires provide conductivity for fault current
Highly corrosion-resistant: ACS wires and aluminum pipe
Convenient splice preparation
Cable design
1 . Central strength member (FRP rod)
2 . Water-swellable yarns
3 . Optical fiber
4 . Gel-filled loose tube
5 . Water-swellable tape
6 . Thermal barrier
7 . Aluminum pipe
8 . Aluminum-clad steel wires and/or
aluminum alloy wires
Parameters• Up to 144 fibers
• Rated breaking strength up to 200 .17 kN
• Max rated design tension up to
200 .17 kN
• Crush – 1 kN/cm
OPGW AP
12
235678 4
Protection of power lines from lightning overvoltage, construction of optical communication systems .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
87
OP
GW
/Gro
un
d W
ire
Features
Aluminum alloy wires shield the high-voltage conductors from lightning strikes
Aluminum-clad steel wires are corrosion resistant
Mandatory element of 35 kV power lines approaching electrical substations and of all 110 kV power line
Cable design
1 . Central strength member (Aluminum-clad
steel wire)
2 . Stranded wires (Aluminum-clad steel wires
and /or aluminum alloy wires)
3 . Stranded wires (Aluminum-clad steel wires
and /or aluminum alloy wires)
Parameters• Rated breaking strength up to 700 kN
Ground wire
123
Protection of power lines from lightning overvoltage, construction of optical communication systems .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
88
Fire
Rat
ed
Fire Rated
Used for stationary installation when the optical fiber needs extra protection from mechanical damages .
Operation parameters
Operation temperature -50°С…+70°С
Installation temperature -10°С…+50°С
Transportation and storage temperature -50°С…+50°С
Minimum bending radius 10×cable diameter
Life time 25 years
We design cables based on our Customers' specific technical Requirements . Please, contact us for a cable designed to your exact specifications .
Discover more
89
Fire
Rat
ed
Cable design
1 . Optical fiber
2 . Stainless steel tube
3 . Armor of steel wires
4 . Halogen-free jacket
1234
Parameters• Up to 96 fibers
• Max rated design tension up to 7 kN
• Crush – 1 kN /cm
Fire Rated Universal
Features
Suitable for all applications
Fire-resistant cable remains functional under influence of flame during 180 minutes
High resistance to crushing (more than 2 kN/cm) which is retained even after a fire
Small size – thin, light, economical
Withstands the physical impact and water used during fire-fighting
For individual installation in cable structures and working spaces .
Сlick here to see detailed features of this design
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
90
Fire
Rat
ed
Cable design
1 . Central strength member (FRP rod)
2 . Optical fiber
3 . Gel-filled loose tube
4 . Water-swellable yarns
5 . Inner jacket made of halogen-free flame-
retardant polymer compound
6 . Corrugated steel tape armor
7 . Halogen-free jacket
12
37 564
Parameters• Up to 144 fibers
• Max rated design tension up to 2 .7 kN
• Crush – 0 .3 kN /cm
Fire Rated Outdoor
Features
Easy to installFire-resistant cable remains functional under influence of flame during 180 minutes
Excellent rodent resistance
For individual installation in cable structures and working spaces .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
91
Fire
Rat
ed
Cable design
1 . Central strength member (FRP rod)
2 . Optical fiber
3 . Gel-filled loose tube
4 . Inner jacket made of halogen-free flame-
retardant polymer compound
5 . Water-sweallable yarns
6 . Fiberglass rods
7 . Fiberglass yarns
8 . Halogen-free jacket
167823
4
5
Parameters• Up to 288 fibers
• Max rated design tension up to 7 kN
• Crush – 0 .4 kN /cm
Fire Rated Universal Dielectric
Features
Suitable for all applications
Remains functional under direct flame for at least 180 minutes
All-dielectric design
For individual installation in cable structures and working spaces .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
92
Fire
Rat
ed
Parameters• Up to 24 fibers
• Max rated design tension up to 1 .1 kN
• Crush — 0 .2 kN/cm
Fire Rated Dielectric
Features
Easy to install
UV resistance
Remains functional under direct flame for at least 180 minutes
All-dielectric design
Cable design
1 . Optical fiber
2 . Tight-buffer
3 . Fiberglass yarns
4 . Inner jacket made of halogen-free flame-
retardant polymer compound
5 . Mica glass tape
6 . Halogen-free jacket
1233 456
Tight-buffered double jacket design for individual installation in cable structures and working spaces .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
93
Fire
Rat
ed
Cable design
1 . Optical fiber
2 . Gel-filled loose tube
3 . Fiberglass yarns
4 . Inner jacket made of halogen-free flame-
retardant polymer compound
5 . Mica glass tape
6 . Halogen-free jacket
1538 234
Parameters• Up to 24 fibers
• Max rated design tension up to 2 kN
• Crush – 0 .2 kN /cm
Fire Rated Dielectric Light
Features
Remains functional under direct flame for at least 180 minutes
All-dielectric design
For individual installation in cable structures and working spaces .
We design cables based on our Customers' specific technical requirements . Please, contact us for a cable designed to your exact specification — info@emcab .co
Сlick here to see detailed features of this design
94
Technical InformationHere you can find useful links, unique free software, up-to-date parameters and color identification of optical fibers, guidelines for transportation, storage and maintenance of fiber optic cable, and other information designed to help you build a reliable optical communication system .
Discover more at emcab .co
95
96
Types and Parameters of Optical Fiber
Corning® Fiber is used in all Emcab cables .
Its fiber attenuation is at least 10% lower than that of the other standard single-mode
fibers .
It is 10-times more bend-resistant compared to other standard single-mode fibers,
and is 100%-compatible with other single-mode fibers .
We normally use Corning optical fibers in our cables, but we can also use fibers of
other manufacturers on request .
Single Mode Fiber
Fiber type A A U U ULL N G .654 .E G .657 .A2 G .657 .B3
Fiber brandCorning® SMF28e+®
Corning® SMF28e+®
LL
Corning® SMF-28®
Ultra
Corning® SMF-28® Ultra
200
Corning® SMF-28®
ULL
Corning® LEAF®
Corning® TXF®
Corning® ClearCurve®
LBL
Corning® ClearCurve®
ZBL
ITU-T recommendation
G .652 .D G .652 .DG .652 .D / G .657 .A1
G .652 .D / G .657 .A1
G .652 .B / G .654 .C
G .655 .D G .654 .EG .652 .D /
G .657 .A2/B2G .657 .B3
Dimensional Specifications
Core-Clad Concentricity
≤ 0 .5 ≤ 0 .5 ≤ 0 .5 ≤ 0 .5 ≤ 0 .5 ≤ 0 .5 ≤ 0 .5 ≤ 0 .5 ≤ 0 .5
Cladding Diameter 125 .0 ± 0 .7 125 .0 ± 0 .7 125 .0 ± 0 .7 125 .0 ± 0 .7 125 .0 ± 0 .7 125 .0 ± 0 .7 125 .0 ± 0 .7 125 .0 ± 0 .7 125 .0 ± 0 .7
Cladding Non-Circularity
≤ 0 .7% ≤ 0 .7% ≤ 0 .7% ≤ 0 .7% ≤ 0 .7% ≤ 0 .7% ≤ 0 .7% ≤ 0 .7% ≤ 0 .7%
Coating Diameter 242 ± 5 242 ± 5 242 ± 5 242 ± 5 242 ± 5 242 ± 5 242 ± 5 242 ± 5 242 ± 5
Transmission Specifications
Wavelength, nm 1310 - 1625 1310 - 1625 1310 - 1625 1310 - 1625 1310 - 1625 1550 1550 - 1625 1310 - 1625 1310 - 1625
Discover more
97
Maximum Attenuation (dB/km):
1310 nm wavelength1383 nm wavelength1490 nm wavelength1550 nm wavelength1625 nm wavelength
≤ 0 .35≤ 0 .35≤ 0 .24≤ 0 .20≤ 0 .23
≤ 0 .32≤ 0 .32≤ 0 .21≤ 0 .18≤ 0 .20
0 .32≤ 0 .32≤ 0 .21≤ 0 .18≤ 0 .20
0 .32≤ 0 .32≤ 0 .21≤ 0 .18≤ 0 .20
≤ 0 .31--
≤ 0 .17≤ 0 .20
-≤ 0 .40
-≤ 0 .19≤ 0 .21
---
≤ 0 .17≤ 0 .19
≤ 0 .35≤ 0 .35≤ 0 .24≤ 0 .20≤ 0 .23
≤ 0 .35≤ 0 .35≤ 0 .24≤ 0 .20≤ 0 .23
Dispersion ps/(nm*km)
1550 nm wavelength1625 nm wavelength
≤ 18≤ 22
≤ 18≤ 22
≤ 18≤ 22
≤ 18≤ 22
≤ 18≤ 22
410
≤ 23≤ 29
≤ 18≤ 23
≤ 18≤ 23
Polarization Mode Dispersion (PMD), ps/√km
≤ 0 .1 ≤ 0 .1 ≤ 0 .1 ≤ 0 .1 ≤ 0 .1 ≤ 0 .1 ≤ 0 .1 ≤ 0 .2 ≤ 0 .2
Zero Dispersion 0,092 0,092 0,092 0,092 0,092 0,07 0,092 0,092 -
Zero Dispersion Wavelength, nm
1304 - 1324 1304 - 1324 1304 - 1324 1304 - 1324 1304 - 1324 - 1304 - 1324 1304 - 1324 -
Cable Cutoff Wavelength, nm
≤ 1260 ≤ 1260 ≤ 1260 ≤ 1260 ≤ 1260 ≤ 1360 ≤ 1520 ≤ 1260 ≤ 1260
Mode-Field Diameter, (μm)
1310 nm wavelength1550 nm wavelength
9 .2 ± 0 .410 .4 ± 0 .5
9 .2 ± 0 .410 .4 ± 0 .5
9 .2 ± 0 .410 .4 ± 0 .5
9 .2 ± 0 .410 .4 ± 0 .5
9 .2 ± 0 .410 .4 ± 0 .5
-9 .6 ± 0 .4
-12 .4 ± 0 .5
8 .6 ± 0 .49 .6 ± 0 .5
8 .6 ± 0 .49 .6 ± 0 .5
Macrobend Loss, dB, λ=1550 nm/1625 nm
(1 turn × R16 mm)(1 turn × R10 mm)(1 turn × R7 .5 mm)(1 turn × R5 mm)(100 turns × R25 mm)(100 turns × R30 mm)
≤ 0 .03 / -----
- / ≤ 0 .03
≤ 0 .03 / -----
- / ≤ 0 .03
-≤ 0 .50 / ≤ 1 .5
----
-≤ 0 .50 / ≤ 1 .5
----
≤ 0 .1 / -----
- / ≤ 0 .05
≤ 0 .50 / ≤ 0 .50----
≤ 0 .05 / ≤ 0 .05
----
≤ 0 .1 / ≤ 0 .1 -
--
≤ 0 .4 / ≤ 0 .8---
---
≤ 0 .10 / ≤ 0 .30--
Fiber type A A U U ULL N G .654 .E G .657 .A2 G .657 .B3
98
Multi-Mode Fiber
Fiber type ‘M’ Type ‘G’ Type
ОМ2 ОМ3 ОМ4 ОМ5 OM1
Fiber brandCorning® ClearCurve®
OM2Corning®
ClearCurve® OM3Corning®
ClearCurve® OM4Corning®
ClearCurve® OM5Corning® InfiniCor®
300
Standard ITU-T G .651 ITU-T G .651 ITU-T G .651 ITU-T G .651 IEC 60793-2-10
Dimensional Specifications
Core Diameter 50 .0 ± 2 .5 50 .0 ± 2 .5 50 .0 ± 2 .5 50 .0 ± 2 .5 62 .5 ± 2 .5
Core-Clad Concentricity ≤ 1 .5 ≤ 1 .5 ≤ 1 .5 ≤ 1 .5 ≤ 1 .5
Cladding Diameter 125 .0 ± 1 .0 125 .0 ± 1 .0 125 .0 ± 1 .0 125 .0 ± 1 .0 125 .0 ± 2 .0
Cladding Non-Circularity ≤ 1 .0% ≤ 1 .0% ≤ 1 .0% ≤ 1 .0% ≤ 1 .0%
Coating Diameter 242 ± 5 242 ± 5 242 ± 5 242 ± 5 242 ± 5
Maximum Attenuation (dB/km)
850 nm wavelength ≤ 2 .3 ≤ 2 .3 ≤ 2 .3 ≤ 2 .3 ≤ 2 .9
953 nm wavelength - - - ≤ 1 .7 -
1300 nm wavelength ≤ 0 .6 ≤ 0 .6 ≤ 0 .6 ≤ 0 .6 ≤ 0 .6
Numerical Aperture 0 .200 ± 0 .015 0 .200 ± 0 .015 0 .200 ± 0 .015 0 .200 ± 0 .015 0 .275 ± 0 .015
Overfilled Bandwidth (MHz * km)
850 nm wavelength 700 1500 3500 3500 200
953 nm wavelength - - - 1850 -
1300 nm wavelength 500 500 500 500 500
Effective Group Index of Retraction
850 nm wavelength 1,482 1,482 1,482 1,482 1,496
1300 nm wavelength 1,477 1,477 1,477 1,477 1,491
99
Fiber type ‘M’ Type ‘G’ Type
ОМ2 ОМ3 ОМ4 ОМ5 OM1
Fiber brandCorning® ClearCurve®
OM2Corning®
ClearCurve® OM3Corning®
ClearCurve® OM4Corning®
ClearCurve® OM5Corning® InfiniCor®
300
Standard ITU-T G .651 ITU-T G .651 ITU-T G .651 ITU-T G .651 IEC 60793-2-10
Attenuation to macrobending (2 turns on a bend former, radius of 15 mm), dB:
at a wavelength of 850 nm ≤ 0 .1 ≤ 0 .1 ≤ 0 .1 ≤ 0 .1 –
at a wavelength of 1300 nm ≤ 0 .3 ≤ 0 .3 ≤ 0 .3 ≤ 0 .3 –
Attenuation to macrobending (2 turns on a bend former, radius of 7.5 mm), dB:
at a wavelength of 850 nm ≤ 0 .2 ≤ 0 .2 ≤ 0 .2 ≤ 0 .2 –
at a wavelength of 1300 nm ≤ 0 .5 ≤ 0 .5 ≤ 0 .5 ≤ 0 .5 –
100
Color Identification
ANSI / TIA 598 DIN VDE 0888
Fiber/Tube count
Blue
Orange
Green
Brown
Slate
White
Red
Black
Yellow
Violet
Rose
Aqua
Blue with ring marks
Orange with ring marks
Green with ring marks
Brown with ring marks
Slate with ring marks
White with ring marks
Red with ring marks
Natural with ring marks
Yellow with ring marks
Violet with ring marks
Rose with ring marks
Aqua with ring marks
24 16 12 8 4 Fiber/Tube count
Red
Green
Blue
Yellow
White
Slate
Brown
Violet
Aqua
Black
Orange
Rose
Red with ring marks
Green with ring marks
Blue with ring marks
Yellow with ring marks
White with ring marks
Slate with ring marks
Brown with ring marks
Violet with ring marks
Aqua with ring marks
Natural
Orange with ring marks
Rose with ring marks
24 16 12 8 4
We use all the main color coding systems . Other color identifications are available on request .
Discover more
101
S12 FIN2012
Fiber/Tube count
Red
Blue
White
Green
Yellow
Slate
Brown
Black
Violet
Orange
Aqua
Rose
Red with ring marks
Blue with ring marks
White with ring marks
Green with ring marks
Yellow with ring marks
Slate with ring marks
Brown with ring marks
Natural with ring marks
Violet with ring marks
Orange with ring marks
Aqua with ring marks
Rose with ring marks
24 16 12 8 4 Fiber/Tube count
Blue
White
Yellow
Green
Slate
Orange
Brown
Aqua
Black
Violet
Rose
Red
Blue with ring marks
White with ring marks
Yellow with ring marks
Green with ring marks
Slate with ring marks
Orange with ring marks
Brown with ring marks
Aqua with ring marks
Natural with ring marks
Violet with ring marks
Rose with ring marks
Red with ring marks
24 16 12 8 4
102
Marking systemMarking is printed through each meter according to Emcab standard below or individual customer requirements .
Discover more
Emcab A-DQ2Y 288 24×12 G.652D+G.657.A1
Manufacturer
Cable type
Number of loose tubes
Fibers per loose tube
Fiber count
103
650N Ø9.5 mm BATCH 2020 00001 mG.652D+G.657.A1
Fiber type
Cable diameter
Batch number
Year of production
Operation tension
Meter marking
104
Always store reels upright and chock securely!
Always lift from the bottom!
Always lift from the side!
Never store or put reels on their side!
Never lift from the front or back!
Always use a steel bar when hoisting by crane!
Never lift from thehub or interior!
Never lift directily with the rigging when hoisting by crane!
steel bar
chock
Transportation. Storage. Installation
Transportation Guides:
• The reels should not be placed on their sides .
• The reels should be fixed . No nailing is allowed while fixing
the reels .
• The truck should have a wooden floor .
Installation guideline overview. Ask Emcab for the installation guidelines for the specific cable you are using:
• Our cables are designed for installation by hand or standard
installation equipment .
• Cable termination and installation should be done in ways and
with instruments that eliminate the danger of cable damage .
• Basic requirements:
— Length of cable axial torsion at an angle ±360° ≥4 m
— Admissible static bending radius for duct cables ≥250 mm
— Admissible static bending radius of loose tube
≥20 × cable diameter
Storage Guides:
• The reels should be protected from mechanical impact, as well
as from sunlight, precipitation and dust .
• The reels should not be placed on their sides .
• The storage temperature range is from -50⁰С to +50⁰С .
Discover more
105
B
Reel Dimensions
Reel Type Dimensions, mm Reel weightincluding
lagging, kgA B C D E
4 400 370 162 305 80 5
5 500 560 320 500 80 9
6 600 560 320 500 80 10
8b 800 646 450 500 80 50
10 1000 646 545 500 80 95
12 1220 650 650 500 80 125
12а 1220 864 650 710 80 145
14 1400 875 750 710 80 198
14g 1400 1065 750 900 80 206
16а 1600 970 800 800 80 273
17а 1700 1094 900 900 80 330
17mod 1700 1294 900 1100 80 440
18а 1800 1120 900 900 80 400
18mod 1800 1320 900 1100 80 500
18u 1800 1230 1000 1000 80 650
D
A
С
E
Discover more
Roll this way
4583/2019
Optical cableEMCAB
Shipping and handling summary
Always store reels upright and chock securely!
Always lift from the bottom!
Always lift from the side!
Never store or put reels on their side!
Never lift from the front or back!
Always use a steel bar when hoisting by crane!
Never lift from thehub or interior!
Never lift directily with the rigging when hoisting by crane!
steel bar
chock
106
Digital AssistantsTry our free automated tools which help you choose suitable reel and simplify your ordering process .
Reel Capacity CalculatorBy entering cable diameter and weight (if needed) you will be offered the
available reel options for the required cable length and total reel capacity . It will
calculate the maximum reel length and total weight of reel with cable which is
essential for your logistics purposes .
Discover more
107
Truck Load CalculatorBy entering the required cable diameter and weight you'll see how many
reels can be placed on the truck and efficiently plan your logistics .
The truck dimensions can be customised, too .
Discover more
108
CertificationWe care about producing and supplying the high-quality products
that meet the best international standards .
The management systems used in production are recognized
as ISO compliant .
All materials used in cables manufacturing are RoHS compliant
and all manufacturing processes are REACH compliant .
Discover more
Conformity to RoHS and REACH
Certificate ISO 9001, ISO 14001, ISO 45001
109
110
Emcab GmbH
An der Flurscheide 7
99098 Erfurt Germany
info@emcab .co
Robert Deffa-Wilk
Managing Director
r .deffa-wilk@emcab .co
Benelux
Jan De Vries
+31 85 273 1819
jandev@emtelle .com
Germany
Ralf Gorontzi
+49 2864 9505010
ralfg@emtelle .com
Eastern Europe
Hans Werner Wilk
+49 176 40354052
hansw@emtelle .com
Denmark
Laila Pedersen
+45 86 28 84 88
LailaNP@emtelle .com
Norway and Sweden
Johan Schalin
+46 10 475 49 92
johans@emtelle .com
UK and Ireland
David Parsons
+44 01246 415336
davidp@emtelle .com
Marian Rus
Key Account Manager
m .rus@emcab .co
Alexander Wiebe
Key Account Manager
a .wiebe@emcab .co
Jan Čeněk
Sales and Customer
Support Manager
j .cenek@emcab .co
Mandy Cash
Sales Coordinator
mandy .cash@emcab .co
Management
European Queries
Sales team
Contacts
111
Emcab.coDiscover more
EmbraceEmcab-lit vibe
Contact us
The package solution for blowing technology
ABC Configurator
#followemcab