supreme water disinfection all round

Upload: grundfosegypt

Post on 03-Apr-2018

221 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/29/2019 Supreme Water disinfection ALL ROUND

    1/8

    GRUNDFOS Management A/SPoul Due Jensens Vej 7DK-8850 BjerringbroTel: +45 87 50 14 00

    www.grundfos.com

    The Oxiperm Pro oers superior water disinection

    technology or all types o water systems. It has the

    ollowing, unique eatures:

    Destroysbothfreebacteriaandbiolm

    Useschlorinedioxide,whichisextremelyecient,

    buthasnoeectonthetasteandsmellofthewater

    TherobustdesignoftheOxipermProensureshigh

    operationalreliabilityandlowmaintenancecosts

    User-friendlyoperation

    Easyinstallationwithnointerruptionofthe

    buildingswatersupply

    GRUNDFOS

    OXIPERM PRO

    supreme Water

    disinfectionaLL round cHLorine dioXide soLutions

    GRUNDFOS

    OXIPERM PRO

    96974125

    0409

  • 7/29/2019 Supreme Water disinfection ALL ROUND

    2/8

    The GRUNDFOS OxipeRm pRO

    SySTem eNSUReS eFFecTive

    DiSiNFecTiON OF waTeR iNa SeRieS OF applicaTiON aReaS

    Water disinection is o great importance in all buildings

    with drinking water consumption, and particularly in

    buildings that supply shower and bathing acilities. Water

    disinection is also essential in applications where water

    mist is sprayed into the air, or instance cooling towers

    and evaporative condensers.

    Grundos Oxiperm Pro system ensures sae, clean water

    to all its end users in buildings such as:

    Hotels Hospitals

    Sportsandswimmingfacilities

    Fitnesscentres

    Wellnessresorts

    Residentialbuildings

    The problemNaturally,thewaterwedrinkandshowerinhastobe

    cleanifwearetostayhealthy.Unfortunately,oneof

    the most widespread health hazards in drinking water

    installations worldwide is connected to exceptionally

    resistantbacterialegionella.

    Legionella exist mainly in hot water systems with a

    lowowrate,areasofstagnationorbadlyserviced

    hot water tanks. A layer o slime in the water pipes

    calledbiolmisthehabitatforlegionellaandother

    microorganisms.Thebacterialive,breedandthrive

    inbiolmintemperaturesbetween30and50Cand

    theyconstituteaseverehealthrisk.

    The solutionThe Grundos Oxiperm Pro system is the all round

    solutiontothehazardofbothlegionellaandother

    kinds o micro organisms. It oers the ollowing

    uniquebenetsthatremainunmatchedbyother

    disinection methods:

    Worksonbothbacteriaandbiolm

    Aectshighlychlorineresistantgerms

    Ecientinareasofthepipesystemwith

    no fow (dead ends)

    Noeectonthetasteandsmellofthewater

    Sustainedreleaseeectforlong-termdisinfection

    OXIPERM PROintroduction

    leGiONella cONTROl beGiNS heRe

    Worldwide drinking water regulations require clean

    and healthy water ree o:

    Bacteria(legionella,salmonellaetc.) Viruses(hepatitis,polio,norovirusetc.)

    Parasites(giardia,cryptosporidium,entamoebaetc.)

    Fungusspores(yeast,mouldsetc.)

    Drinking water regulations

  • 7/29/2019 Supreme Water disinfection ALL ROUND

    3/8

    What are legionella bacteria?Legionellabacteriaaretheprimarysourceof

    legionnairesdiseaseapotentiallyfataldisease,

    particularly or those with a weakened immune

    system.Itisestimatedthatlegionnairesdiseaseis

    responsiblefor15-20,000deathsinEuropeeveryyear.

    Legionellabacteriaandthebiolmwheretheylive

    and eed are highly resistant to most disinection

    methods.Thatmakeseectivecombatagainstthem

    dicult,andtheirsuccessfuleliminationcallsfor

    specicandhighlyspecialisedsolutions.

    The right solution is both toughand gentleTherearemanyapproachestoghtinglegionella

    bacteriaandbiolm,butnoapproachisasecientor gentle as the Grundos Oxiperm Pro system.

    Thesystemeectivelybattleslegionellaandbiolm

    without aecting the taste and smell o the water.

    BychoosingOxipermPro,youhavemadethe

    right choice or the saety and comort o the end

    consumers.

    Source:RobertKochInstitute,Berlin,2008

    TOUGh pROblem GeNTle SOlUTiON

    OXIPERM PROdisinfection facts

    Characteristics o typical disinection solutions

    Legionellapneumophila;theprimarysourcetolegionnairesdisease.

    residualgerms with

    residual germswith hypochlorite (HClO)

    0

    0 ,0 1 0 ,0 2 0 ,0 3 0 ,0 4 0 ,0 5 0, 06

    20

    40

    60

    80

    100

    Residualgerms[%]

    Concentration of disinfectant [mg/l]

    pH > 7.5

    Comparison of the disinfecting action ofchlorine dioxide and hypochlorite at a pH of 7,5 .

    Comparison o the disinectant action

    Thermal treatment

    UV radiation

    Filtration

    Chlorination (hypochlorite sol.)

    Ozone

    Removes

    biofilm

    Benefits

    Disinfectionprinciple

    Eec

    tiveaga

    ins

    tbac

    teria

    inbiofilm

    Eec

    tiveaga

    ins

    tfree

    bac

    teria

    Aec

    tswa

    ter

    tas

    tean

    dsme

    ll

    Sens

    itive

    towa

    ter-p

    H

    Lifecyc

    lecos

    t

    Usersca

    ldingris

    k

    Long-t

    erm

    eec

    t

    Chlorine dioxide

    = Inferior

    = Average

    = Superior

    No No

    No

    No

    No

    Low Mid No No High Yes

    No No NoHigh No Mid No

    No No No No No Mid

    Mid

    No

    No Mid High Yes Yes Low No

    No No NoHigh No Low No

    HighYes High NoHigh No Low No

    This chart illustrates how thetypical solutions or disinectionperformonanumberofparameters. The chlorine dioxidesolution o the Oxiperm Prosystem is superior to the rest.

  • 7/29/2019 Supreme Water disinfection ALL ROUND

    4/8

    OXIPERM PROtHe Benefits

    The chemistry o great benetsThe Oxiperm Pro system uses chlorine dioxide or

    the disinection o water. This particular chemical

    compoundpresentsanumberofadvantagesthat

    cannotbematchedbyanyotherdisinfection

    method.

    RemovesbothfreelegionellaandbiolmLegionellabacteriagrowandreproduceinbiolmasdoes90%ofallbacteriainwatersystems.Biolmisalayerofslimethatexistsinwaterpipesandespeciallyinhotwatertanks.Chlorinedioxidediusesintothebiolmanddestroysitfromwithin,whereasotherdisinfectantsonlyattackthesurfaceofthelm.

    No eect on water taste and smellChlorinedioxidedoesnotformthetoxicchloraminesandhaloformsthatareaby-productofchlorine-baseddisinfectionmethods.Ineect,thewaterneither tastes nor smells o chlorine with the use othe Oxiperm Pro.

    Long-term eectChlorinedioxidehasthebestresidualeectofalltheavailabledisinection methods. It stays inthewatersystemforseveraldays,reachesintoeverycrackofthepipettings,andevendissolvesintodead-endpipeswithnowaterow.

    Digital dosingThe Oxiperm Pro is a digital dosingsystemwhichmakesitexible,costeectiveandeliminatestheriskofoverdosing.

    Compact designTheOxipermProhasabuilt-inmeasuringapplication,which measures the residual chlorine in the water.It also has an integrated digital dosing pump makingitanall-in-onecompactsolution.

    WaterpHadaptableWithchlorinedioxide,noparticularpHvalueisneeded,whichmakesitanextremelyexibledisinfectant.

    Low lie cycle costWaterdisinfectionwiththeOxipermPromeansreduced chemical use and reduced energyconsumption. The chemical use is reduced due totheadvancedbatch-reaction-technologyandthehigh-precisionowmeasurementsthatadjusttheamountofchemicalstothecurrentowgivingtheOxipermProanextremelylowoveralllifecyclecost.

  • 7/29/2019 Supreme Water disinfection ALL ROUND

    5/8

    OXIPERM PROsiZinG

    Typicaldosingratesinbuildingapplicationsare

    between0,1and0,4g/m.

    The exact quantity o required chlorine dioxide

    isdenedbytestingon-site.Samplesaretaken

    fromthevariouswateroutletsinthebuilding

    and tested or chlorine dioxide residual. Based

    on the residual amount, the unit settings can

    beadjusted.ContactyourlocalGrundfosoce

    foradetailedoverviewoftheguidelinesand

    regulationsrelevanttoyourproject.

    cONceNTRaTiON

    10

    54

    3

    2

    1

    0,50,40,3

    0,2

    0,11 2 3 4 5 10 20 30 40 50 100

    CI02concentra

    tion[g/m]

    m3/hQpeak

    OxipermOCD162-10

    OxipermOCD162-5

    Example: 200 room hotelOxiperm Pro 5 shouldbe used for disinfectionof hot water only

    Example: 200 room hotelOxiperm Pro 10 shouldbe used for disinfectionof both hot and coldwater only

    Selectionchart

    Note:MaximumconcentrationofCI0addedtodrinkingwater depends on national guidelines and regulations.

    Quick glance fow chart, Qpeak

    The required total consumption and maximum fow

    requirementdependsonthebuildingtype.Thereis

    abigdierenceinannualwaterconsumption,dailymaximum consumption and the peak consumption

    inablockofatscomparedtoavestarhotel.Ifyou

    havenoreliableowmeasurementsinthebuilding,

    thetablebelowgivesyouanexampleofhowto

    calculatepeakwaterowinvarioustypesofbuildings

    in order to select the right Oxiperm Pro.

    FlOw

    1

    1 1 0 2 0 5 0 10 0 20 0 5 00 10 00 2 00 0 5 00 0 1 00 00 2 00 00

    2

    4

    6

    8

    10

    20

    40

    60

    80

    100

    200

    400

    600

    800

    1000

    Qpeak[m/h]

    Units

    Hotel

    Resid

    entialb

    uildin

    g

    Ofce

    Scho

    ol

    Example o calculation o maximum hourly

    fow rate in a 200-bed hotel

    Annual water consumption: Qyear=180m3/bed/year

    Consumptionperiod:365days/year

    Averagedailyconsumption:Qavg=180/365=0,5m3/bed/day

    Dayfactor:fd = 1,5

    Maximum daily fow rate: Q max = 0,5 x 1,5 = 0,75 m3/bed/day

    Peak actor: p = 4

    Maximum hourly fow rate per unit: Qpeak=0,75x4/24=0,125m3/bed/hNumberofbeds:n=200

    Maximum hourly fow rate or the whole hotel: Qpeak = 200 x 0,125 = 25

    m3/h(hotandcoldwater)

    Maximum hourly fow rate or the whole hotel: Qpeak = 25 x 0,4 = 10 m3/h

    (hot water only)

    Alternatively,usethequickglanceowcharttotheright.

    Dening peak fow, Qpeak

    AboveguresareassumptionsbasedonDanishlegislationDS442/1989CodeofPracticeforcommonwater-works.Calculationofwaterowetc.mayvaryfromcountrytocountrydependingonnationalguidelinesandlegislation.

    Building Unit Qyear Consumption period Qavg fd Qmax fp Qpeaktype [m per year] [days/year] [m/unit/day] [m/unit/day] [m/unit/h]

    Residentialbuilding Residents(2,5pers.) 183 365 0,5 1,3 0,65 1,7 0,046

    Ocebuildings Employee 25 250 0,1 1,2 0,12 3,6 0,018

    Shoppingcentre Employee 25 300 0,08 1,2 0,1 4,3 0,018

    Supermarket Employee 80 300 0,27 1,5 0,4 3,0 0,050

    Hotel Bed 180 365 0,5 1,5 0,75 4,0 0,125

    Hospital Bed 300 365 0,8 1,2 1,0 3,0 0,120

    School Pupil 20 200 0,1 1,3 0,13 2,5 0,014

  • 7/29/2019 Supreme Water disinfection ALL ROUND

    6/8

    OXIPERM PROtHe Water system

    HOT

    WATER

    TANK

    INJECTION POINT

    HOT AND COLD WATERHOT WATER

    HOT WATER, CIRCULATION

    COLD WATERMUNICIPAL WATER MAIN

    INJECTION POINT.

    HOT WATER ONLY

    Injectionofchlorinedioxideintothewatersystem

    canbedonewhereveritisdeemedsuitable.Ifatotal

    disinfectionisdesired,theinjectionpointshouldbelocatedwherethewatermainentersthebuilding.

    Inmostcases,itissucienttotreatonlythehot

    water system where there is the highest risk o

    bacteriagrowth.

    iNjecTiON pOiNTS

    Avestarhotelmustdelivertheveryhighestlevel

    o comort and saety or its guests. Le Meridien

    BristolinWarsawopenedin1993andreliedonthe

    expertise o Grundos or all its installations.

    Grundfosprovidedcirculationpumps,boosters

    andwastewaterpumps.Toensuretheguests

    protectionfromlegionellabacteria,thehotelchose

    to install the Oxiperm Pro. As a result, the hotel

    cancontinuetoprovideworld-classservice,andthe

    health and saety o its guests is secured.

    le meRiDieN

    bRiSTOl Five

    STaR hOTel iN

    waRSaw

  • 7/29/2019 Supreme Water disinfection ALL ROUND

    7/8

    HClNaCIO

    Waterpipe/tube

    ClOdosingline

    Signalline

    OXIPERM PROtHe detaiLs

    Main water lineWaterowtobetreatedwith chlorine dioxide

    Supplywaterout-takeWatersupplyforOxipermPro

    Sodiumchloritestorage tank30litresstandardcontainer

    Water meterProvidesimpulseoranaloguesignalforproportional dosing o chlorine dioxide

    Chlorine dioxidemeasurementMeasurement module thatcontrols the chlorine dioxideresidual in treated water

    Samplewaterre-feedSamplewaterforchlorinedioxidemeasurementisre-fedtoavoidunnecessary water consumption

    Injection pointDosingpointofchlorinedioxide solution in water line

    Drip pansContainmentforchemicaltankstoavoidchemicalspilling

    Samplewaterout-takeSamplewaterformeasurementofchlorine dioxide residual

    Hydrochloricacidstorage tank30litresstandardcontainer

  • 7/29/2019 Supreme Water disinfection ALL ROUND

    8/8

    ThiNkiNG bUilDiNGS

    AtGrundfosCBS,wearealwaysthinkingbuildings,and

    ourproductscontributetomakingbuildingsthatcan

    almostthinkforthemselves.Wedonotjustconsiderourproductsasstandalonedevicesweconsider

    themanintegralpartofalivingbuildingwhose

    purposeistofunctioninthebestwaypossibleforits

    inhabitants.

    GrundfosCBSoersproductsacrossthefullrangeof

    applications, including heating, air conditioning, waste

    water,boostersystems,reprotectionsystemsand

    district energy.

    Ourexpertiseisfoundedindecadesofglobal

    experience and we are proud to share our knowledge

    withourclients.Wearealsodeterminedtotaketheleadonnewtechnologiesandinnovation

    opportunities.

    TolearnmoreaboutGrundfosCBSandtondout

    howwecanbeofassistance,contactGrundfos

    orvisitusatwww.grundos.com/commercialbuilding.

    explORe OUR ONliNe UNiveRSe

    OXIPERM PROtecHnicaL data

    Technical data

    Chlorinedioxidegenerationcapacity OCD-162-5 5mg/l

    OCD-162-10 10mg/l

    Adjustment of the p repa ra ti on c apac ity manualbymenu-controlledoperatorprompting,

    automaticbyinputsignal

    Protectionlevel IP65 electronics,dosingpumps,solenoidvalve

    Requir ed con cent ra ti on of c hemi cal s HC I (t o EN 939) 9% by weig ht

    NaCIO(toEN938) 7,5%byweight

    Admissible

    ambienttemperature 5-35C

    oper ationwatertemp erature 10-30C

    chemicalstemperature 10-35C

    Admissi bl e operat ionwater pressu re 3 to 6 ba rs

    Admissi bl e re la ti ve a ir humid ity max 80% a t 35 C , no t condensing

    Concentrationofthechlorinedioxide

    productsolution ca.2g/l(2000ppm)

    Material system rack PP

    fasteningsleeves stainlesssteel

    solenoidvalve PVC

    reaction/storagetank PVC

    internalhoses PTFE

    gaskets FPMFulltextmenucontrolfor commissioning

    enteringoperatingparameters

    rinsingthesystem

    maintenance

    Connections dosinglineCIO 230Vhose4/6

    115Vhose1/8x1/4

    dilutionwater 230Vhose6/9or6/12orPVCpipeDN10

    115Vhose1/4x3/8

    Electrical and electronic data

    Mainsconnection 110/120V/50-60Hzor230/240V/50-60Hz

    Powerconsumption ca.50VA

    Analogueinput input0(4)-20mA(watermeter)

    measuringcell(CIOpHorRedox,temperature)(option)

    Digitalinput contactwatermeter(min.3pulses/min.,max.50pulses/sec)

    remoteOn/O

    Analogueoutput output0(4)-20mA(pumpregulation)

    measuredvalueCIO0(4)-20mA

    Potential-fre eoutput alarmrelay, 2 50V/6A ,max.55 0VA

    (chemicals empty signal, dosing time monitoring, preparation process

    timemonitoring,wirebreakcurrentoutput)

    warningrelay,250V/6A,max.550VA

    (chemicalsemptypre-alert,maintenance)

    CIOdosingpump

    MakethemostofGrundfosCBS

    visittheThinkingBuildingsUniverseat

    www.grundos.com/commercialbuilding.

    Ourwebsitecontainsarangeofservicesthat

    functionasyouronlineGrundfosCBSexpert:

    QuickPumpSelectionwithanextensive

    product database and dimensioning tool that

    helps you choose the right pump or your needs

    E-learningprogrammethatletsyouimprove

    your specialist knowledge

    Lexiconwhereyoucanlookupdenitions

    o relevant proessional terms

    SignupforThinkingBuildingsE-NewsNowyoucanhavethelatestnewsonpumpsand

    technologysentstraighttoyourinboxfourtimesayear,

    includingabestofyeareditionwithallourreaders

    favouritearticles.

    WelcometotheGrundfosCBS

    ThinkingBuildingsUniverse!