The Oxiperm Pro oers superior water disinection
technology or all types o water systems. It has the
ollowing, unique eatures:
Destroysbothfreebacteriaandbiolm
Useschlorinedioxide,whichisextremelyecient,
buthasnoeectonthetasteandsmellofthewater
TherobustdesignoftheOxipermProensureshigh
operationalreliabilityandlowmaintenancecosts
User-friendlyoperation
Easyinstallationwithnointerruptionofthe
buildingswatersupply
GRUNDFOS
OXIPERM PRO
supreme Water
disinfectionaLL round cHLorine dioXide soLutions
GRUNDFOS
OXIPERM PRO
96974125
0409
-
7/29/2019 Supreme Water disinfection ALL ROUND
2/8
The GRUNDFOS OxipeRm pRO
SySTem eNSUReS eFFecTive
DiSiNFecTiON OF waTeR iNa SeRieS OF applicaTiON aReaS
Water disinection is o great importance in all buildings
with drinking water consumption, and particularly in
buildings that supply shower and bathing acilities. Water
disinection is also essential in applications where water
mist is sprayed into the air, or instance cooling towers
and evaporative condensers.
Grundos Oxiperm Pro system ensures sae, clean water
to all its end users in buildings such as:
Hotels Hospitals
Sportsandswimmingfacilities
Fitnesscentres
Wellnessresorts
Residentialbuildings
The problemNaturally,thewaterwedrinkandshowerinhastobe
cleanifwearetostayhealthy.Unfortunately,oneof
the most widespread health hazards in drinking water
installations worldwide is connected to exceptionally
resistantbacterialegionella.
Legionella exist mainly in hot water systems with a
lowowrate,areasofstagnationorbadlyserviced
hot water tanks. A layer o slime in the water pipes
calledbiolmisthehabitatforlegionellaandother
microorganisms.Thebacterialive,breedandthrive
inbiolmintemperaturesbetween30and50Cand
theyconstituteaseverehealthrisk.
The solutionThe Grundos Oxiperm Pro system is the all round
solutiontothehazardofbothlegionellaandother
kinds o micro organisms. It oers the ollowing
uniquebenetsthatremainunmatchedbyother
disinection methods:
Worksonbothbacteriaandbiolm
Aectshighlychlorineresistantgerms
Ecientinareasofthepipesystemwith
no fow (dead ends)
Noeectonthetasteandsmellofthewater
Sustainedreleaseeectforlong-termdisinfection
OXIPERM PROintroduction
leGiONella cONTROl beGiNS heRe
Worldwide drinking water regulations require clean
and healthy water ree o:
Bacteria(legionella,salmonellaetc.) Viruses(hepatitis,polio,norovirusetc.)
Parasites(giardia,cryptosporidium,entamoebaetc.)
Fungusspores(yeast,mouldsetc.)
Drinking water regulations
-
7/29/2019 Supreme Water disinfection ALL ROUND
3/8
What are legionella bacteria?Legionellabacteriaaretheprimarysourceof
legionnairesdiseaseapotentiallyfataldisease,
particularly or those with a weakened immune
system.Itisestimatedthatlegionnairesdiseaseis
responsiblefor15-20,000deathsinEuropeeveryyear.
Legionellabacteriaandthebiolmwheretheylive
and eed are highly resistant to most disinection
methods.Thatmakeseectivecombatagainstthem
dicult,andtheirsuccessfuleliminationcallsfor
specicandhighlyspecialisedsolutions.
The right solution is both toughand gentleTherearemanyapproachestoghtinglegionella
bacteriaandbiolm,butnoapproachisasecientor gentle as the Grundos Oxiperm Pro system.
Thesystemeectivelybattleslegionellaandbiolm
without aecting the taste and smell o the water.
BychoosingOxipermPro,youhavemadethe
right choice or the saety and comort o the end
consumers.
Source:RobertKochInstitute,Berlin,2008
TOUGh pROblem GeNTle SOlUTiON
OXIPERM PROdisinfection facts
Characteristics o typical disinection solutions
Legionellapneumophila;theprimarysourcetolegionnairesdisease.
residualgerms with
residual germswith hypochlorite (HClO)
0
0 ,0 1 0 ,0 2 0 ,0 3 0 ,0 4 0 ,0 5 0, 06
20
40
60
80
100
Residualgerms[%]
Concentration of disinfectant [mg/l]
pH > 7.5
Comparison of the disinfecting action ofchlorine dioxide and hypochlorite at a pH of 7,5 .
Comparison o the disinectant action
Thermal treatment
UV radiation
Filtration
Chlorination (hypochlorite sol.)
Ozone
Removes
biofilm
Benefits
Disinfectionprinciple
Eec
tiveaga
ins
tbac
teria
inbiofilm
Eec
tiveaga
ins
tfree
bac
teria
Aec
tswa
ter
tas
tean
dsme
ll
Sens
itive
towa
ter-p
H
Lifecyc
lecos
t
Usersca
ldingris
k
Long-t
erm
eec
t
Chlorine dioxide
= Inferior
= Average
= Superior
No No
No
No
No
Low Mid No No High Yes
No No NoHigh No Mid No
No No No No No Mid
Mid
No
No Mid High Yes Yes Low No
No No NoHigh No Low No
HighYes High NoHigh No Low No
This chart illustrates how thetypical solutions or disinectionperformonanumberofparameters. The chlorine dioxidesolution o the Oxiperm Prosystem is superior to the rest.
-
7/29/2019 Supreme Water disinfection ALL ROUND
4/8
OXIPERM PROtHe Benefits
The chemistry o great benetsThe Oxiperm Pro system uses chlorine dioxide or
the disinection o water. This particular chemical
compoundpresentsanumberofadvantagesthat
cannotbematchedbyanyotherdisinfection
method.
RemovesbothfreelegionellaandbiolmLegionellabacteriagrowandreproduceinbiolmasdoes90%ofallbacteriainwatersystems.Biolmisalayerofslimethatexistsinwaterpipesandespeciallyinhotwatertanks.Chlorinedioxidediusesintothebiolmanddestroysitfromwithin,whereasotherdisinfectantsonlyattackthesurfaceofthelm.
No eect on water taste and smellChlorinedioxidedoesnotformthetoxicchloraminesandhaloformsthatareaby-productofchlorine-baseddisinfectionmethods.Ineect,thewaterneither tastes nor smells o chlorine with the use othe Oxiperm Pro.
Long-term eectChlorinedioxidehasthebestresidualeectofalltheavailabledisinection methods. It stays inthewatersystemforseveraldays,reachesintoeverycrackofthepipettings,andevendissolvesintodead-endpipeswithnowaterow.
Digital dosingThe Oxiperm Pro is a digital dosingsystemwhichmakesitexible,costeectiveandeliminatestheriskofoverdosing.
Compact designTheOxipermProhasabuilt-inmeasuringapplication,which measures the residual chlorine in the water.It also has an integrated digital dosing pump makingitanall-in-onecompactsolution.
WaterpHadaptableWithchlorinedioxide,noparticularpHvalueisneeded,whichmakesitanextremelyexibledisinfectant.
Low lie cycle costWaterdisinfectionwiththeOxipermPromeansreduced chemical use and reduced energyconsumption. The chemical use is reduced due totheadvancedbatch-reaction-technologyandthehigh-precisionowmeasurementsthatadjusttheamountofchemicalstothecurrentowgivingtheOxipermProanextremelylowoveralllifecyclecost.
-
7/29/2019 Supreme Water disinfection ALL ROUND
5/8
OXIPERM PROsiZinG
Typicaldosingratesinbuildingapplicationsare
between0,1and0,4g/m.
The exact quantity o required chlorine dioxide
isdenedbytestingon-site.Samplesaretaken
fromthevariouswateroutletsinthebuilding
and tested or chlorine dioxide residual. Based
on the residual amount, the unit settings can
beadjusted.ContactyourlocalGrundfosoce
foradetailedoverviewoftheguidelinesand
regulationsrelevanttoyourproject.
cONceNTRaTiON
10
54
3
2
1
0,50,40,3
0,2
0,11 2 3 4 5 10 20 30 40 50 100
CI02concentra
tion[g/m]
m3/hQpeak
OxipermOCD162-10
OxipermOCD162-5
Example: 200 room hotelOxiperm Pro 5 shouldbe used for disinfectionof hot water only
Example: 200 room hotelOxiperm Pro 10 shouldbe used for disinfectionof both hot and coldwater only
Selectionchart
Note:MaximumconcentrationofCI0addedtodrinkingwater depends on national guidelines and regulations.
Quick glance fow chart, Qpeak
The required total consumption and maximum fow
requirementdependsonthebuildingtype.Thereis
abigdierenceinannualwaterconsumption,dailymaximum consumption and the peak consumption
inablockofatscomparedtoavestarhotel.Ifyou
havenoreliableowmeasurementsinthebuilding,
thetablebelowgivesyouanexampleofhowto
calculatepeakwaterowinvarioustypesofbuildings
in order to select the right Oxiperm Pro.
FlOw
1
1 1 0 2 0 5 0 10 0 20 0 5 00 10 00 2 00 0 5 00 0 1 00 00 2 00 00
2
4
6
8
10
20
40
60
80
100
200
400
600
800
1000
Qpeak[m/h]
Units
Hotel
Resid
entialb
uildin
g
Ofce
Scho
ol
Example o calculation o maximum hourly
fow rate in a 200-bed hotel
Annual water consumption: Qyear=180m3/bed/year
Consumptionperiod:365days/year
Averagedailyconsumption:Qavg=180/365=0,5m3/bed/day
Dayfactor:fd = 1,5
Maximum daily fow rate: Q max = 0,5 x 1,5 = 0,75 m3/bed/day
Peak actor: p = 4
Maximum hourly fow rate per unit: Qpeak=0,75x4/24=0,125m3/bed/hNumberofbeds:n=200
Maximum hourly fow rate or the whole hotel: Qpeak = 200 x 0,125 = 25
m3/h(hotandcoldwater)
Maximum hourly fow rate or the whole hotel: Qpeak = 25 x 0,4 = 10 m3/h
(hot water only)
Alternatively,usethequickglanceowcharttotheright.
Dening peak fow, Qpeak
AboveguresareassumptionsbasedonDanishlegislationDS442/1989CodeofPracticeforcommonwater-works.Calculationofwaterowetc.mayvaryfromcountrytocountrydependingonnationalguidelinesandlegislation.
Building Unit Qyear Consumption period Qavg fd Qmax fp Qpeaktype [m per year] [days/year] [m/unit/day] [m/unit/day] [m/unit/h]
Residentialbuilding Residents(2,5pers.) 183 365 0,5 1,3 0,65 1,7 0,046
Ocebuildings Employee 25 250 0,1 1,2 0,12 3,6 0,018
Shoppingcentre Employee 25 300 0,08 1,2 0,1 4,3 0,018
Supermarket Employee 80 300 0,27 1,5 0,4 3,0 0,050
Hotel Bed 180 365 0,5 1,5 0,75 4,0 0,125
Hospital Bed 300 365 0,8 1,2 1,0 3,0 0,120
School Pupil 20 200 0,1 1,3 0,13 2,5 0,014
-
7/29/2019 Supreme Water disinfection ALL ROUND
6/8
OXIPERM PROtHe Water system
HOT
WATER
TANK
INJECTION POINT
HOT AND COLD WATERHOT WATER
HOT WATER, CIRCULATION
COLD WATERMUNICIPAL WATER MAIN
INJECTION POINT.
HOT WATER ONLY
Injectionofchlorinedioxideintothewatersystem
canbedonewhereveritisdeemedsuitable.Ifatotal
disinfectionisdesired,theinjectionpointshouldbelocatedwherethewatermainentersthebuilding.
Inmostcases,itissucienttotreatonlythehot
water system where there is the highest risk o
bacteriagrowth.
iNjecTiON pOiNTS
Avestarhotelmustdelivertheveryhighestlevel
o comort and saety or its guests. Le Meridien
BristolinWarsawopenedin1993andreliedonthe
expertise o Grundos or all its installations.
Grundfosprovidedcirculationpumps,boosters
andwastewaterpumps.Toensuretheguests
protectionfromlegionellabacteria,thehotelchose
to install the Oxiperm Pro. As a result, the hotel
cancontinuetoprovideworld-classservice,andthe
health and saety o its guests is secured.
le meRiDieN
bRiSTOl Five
STaR hOTel iN
waRSaw
-
7/29/2019 Supreme Water disinfection ALL ROUND
7/8
HClNaCIO
Waterpipe/tube
ClOdosingline
Signalline
OXIPERM PROtHe detaiLs
Main water lineWaterowtobetreatedwith chlorine dioxide
Supplywaterout-takeWatersupplyforOxipermPro
Sodiumchloritestorage tank30litresstandardcontainer
Water meterProvidesimpulseoranaloguesignalforproportional dosing o chlorine dioxide
Chlorine dioxidemeasurementMeasurement module thatcontrols the chlorine dioxideresidual in treated water
Samplewaterre-feedSamplewaterforchlorinedioxidemeasurementisre-fedtoavoidunnecessary water consumption
Injection pointDosingpointofchlorinedioxide solution in water line
Drip pansContainmentforchemicaltankstoavoidchemicalspilling
Samplewaterout-takeSamplewaterformeasurementofchlorine dioxide residual
Hydrochloricacidstorage tank30litresstandardcontainer
-
7/29/2019 Supreme Water disinfection ALL ROUND
8/8
ThiNkiNG bUilDiNGS
AtGrundfosCBS,wearealwaysthinkingbuildings,and
ourproductscontributetomakingbuildingsthatcan
almostthinkforthemselves.Wedonotjustconsiderourproductsasstandalonedevicesweconsider
themanintegralpartofalivingbuildingwhose
purposeistofunctioninthebestwaypossibleforits
inhabitants.
GrundfosCBSoersproductsacrossthefullrangeof
applications, including heating, air conditioning, waste
water,boostersystems,reprotectionsystemsand
district energy.
Ourexpertiseisfoundedindecadesofglobal
experience and we are proud to share our knowledge
withourclients.Wearealsodeterminedtotaketheleadonnewtechnologiesandinnovation
opportunities.
TolearnmoreaboutGrundfosCBSandtondout
howwecanbeofassistance,contactGrundfos
orvisitusatwww.grundos.com/commercialbuilding.
explORe OUR ONliNe UNiveRSe
OXIPERM PROtecHnicaL data
Technical data
Chlorinedioxidegenerationcapacity OCD-162-5 5mg/l
OCD-162-10 10mg/l
Adjustment of the p repa ra ti on c apac ity manualbymenu-controlledoperatorprompting,
automaticbyinputsignal
Protectionlevel IP65 electronics,dosingpumps,solenoidvalve
Requir ed con cent ra ti on of c hemi cal s HC I (t o EN 939) 9% by weig ht
NaCIO(toEN938) 7,5%byweight
Admissible
ambienttemperature 5-35C
oper ationwatertemp erature 10-30C
chemicalstemperature 10-35C
Admissi bl e operat ionwater pressu re 3 to 6 ba rs
Admissi bl e re la ti ve a ir humid ity max 80% a t 35 C , no t condensing
Concentrationofthechlorinedioxide
productsolution ca.2g/l(2000ppm)
Material system rack PP
fasteningsleeves stainlesssteel
solenoidvalve PVC
reaction/storagetank PVC
internalhoses PTFE
gaskets FPMFulltextmenucontrolfor commissioning
enteringoperatingparameters
rinsingthesystem
maintenance
Connections dosinglineCIO 230Vhose4/6
115Vhose1/8x1/4
dilutionwater 230Vhose6/9or6/12orPVCpipeDN10
115Vhose1/4x3/8
Electrical and electronic data
Mainsconnection 110/120V/50-60Hzor230/240V/50-60Hz
Powerconsumption ca.50VA
Analogueinput input0(4)-20mA(watermeter)
measuringcell(CIOpHorRedox,temperature)(option)
Digitalinput contactwatermeter(min.3pulses/min.,max.50pulses/sec)
remoteOn/O
Analogueoutput output0(4)-20mA(pumpregulation)
measuredvalueCIO0(4)-20mA
Potential-fre eoutput alarmrelay, 2 50V/6A ,max.55 0VA
(chemicals empty signal, dosing time monitoring, preparation process
timemonitoring,wirebreakcurrentoutput)
warningrelay,250V/6A,max.550VA
(chemicalsemptypre-alert,maintenance)
CIOdosingpump
MakethemostofGrundfosCBS
visittheThinkingBuildingsUniverseat
www.grundos.com/commercialbuilding.
Ourwebsitecontainsarangeofservicesthat
functionasyouronlineGrundfosCBSexpert:
QuickPumpSelectionwithanextensive
product database and dimensioning tool that
helps you choose the right pump or your needs
E-learningprogrammethatletsyouimprove
your specialist knowledge
Lexiconwhereyoucanlookupdenitions
o relevant proessional terms
SignupforThinkingBuildingsE-NewsNowyoucanhavethelatestnewsonpumpsand
technologysentstraighttoyourinboxfourtimesayear,
includingabestofyeareditionwithallourreaders
favouritearticles.
WelcometotheGrundfosCBS
ThinkingBuildingsUniverse!