System GC Petrochemical Applications
System Name Methods Sample Types Analytes Part Number
Refi nery Gas AnalyzerASTM 7833ASTM 1945
Refi nery GasC1-C5 (paraffi ns and olefi ns) C6+ composite, H2, O2, N2, CO2, H2S (optional)
220-90867-30
Sulfur in Natural Gas AnalyzerASTM 5504GPA 2286
Natural Gas Hydrocarbons and sulfurs 220-94884-30
Sulfur in Liquefi ed and Natural Gas Analyzer
ASTM 5504GPA 2186GPA 2286
Liquefi ed Natural Gas,Natural Gas
Hydrocarbons and sulfurs 220-94884-31
Extended Liquefi ed and Natural Gas Analyzer
GPA 2261GPA 2177GPA 2186GPA 2286
Liquefi ed Natural Gas,Natural Gas
C1-C5 (methane, ethane, propane, iso-butane, n-butane, iso-pentane, n-pentane), C14, CO2, N2
220-94922-30
Extended Natural Gas AnalyzerGPA 2261GPA 2286
Natural Gas
C1-C5 (methane, ethane, propane, iso-butane, n-butane, iso-pentane, n-pentane), C14, CO2, N2
220-94889-30220-94889-24
Extended Liquefi ed Natural Gas Analyzer
GPA 2177GPA 2186
Liquefi ed Natural Gas
C1-C5 (methane, ethane, propane, iso-butane, n-butane, iso-pentane, n-pentane), C14, CO2, N2
220-94825-44220-94825-30
Natural Gas Analyzer GPA 2261 Natural GasC1-C5 (methane, ethane, propane, iso-butane, n-butane, iso-pentane, n-pentane), CO2, N2
220-90851-30220-90851-24
Liquefi ed Natural Gas Analyzer GPA 2177 Liquefi ed Natural GasC1-C5 (methane, ethane, propane, iso-butane, n-butane, iso-pentane, n-pentane), CO2, N2
220-90861-24
Liquefi ed and Natural Gas Analyzer
GPA 2261GPA 2177
Liquefi ed Natural Gas,Natural Gas
C1-C5 (methane, ethane, propane, iso-butane, n-butane, iso-pentane, n-pentane), CO2, N2
220-94802-24
Liquefi ed and Natural Gas with Permanent Gas Analyzer
GPA 2261GPA 2177ASTM 1945
Liquefi ed Natural Gas,Natural Gas
C1-C5 (methane, ethane, propane, iso-butane, n-butane, iso-pentane, n-pentane), CO2, O2, N2, CO
220-94952-24
Extended Liquefi ed and Natural Gas with Permanent Gas Analyzer
GPA 2261GPA 2177GPA 2186GPA 2286ASTM 1945
Liquefi ed Natural Gas,Natural Gas
C1-C5 (methane, ethane, propane, iso-butane, n-butane, iso-pentane, n-pentane), C14, CO2, O2, N2, CO
220-94887-30
Shimadzu Scientifi c Instruments, 7102 Riverwood Drive, Columbia, MD 21046Phone: 800-477-1227; www.ssi.shimadzu.com
Shimadzu’s System GC program provides customers with the best applicated and fully-confi gured GC products available. We offer pre-confi gured systems applicated for a variety of industry-standard test methods. Reference the table below to fi nd the right system for your application.