tceq - 40 cfr part 60, subpart db; flowchart; december 20 ... · subpart da? §60.40b(e) no...

67
§60.40b(a) Is the unit an industrial-commercial- institutional steam generating unit with a heat input > 100 MMBtu/hr that was constructed, modified, or reconstructed after 06/19/1984? End 40 CFR Part 60, Subpart Db does not apply. Start 1 Does the affected facility meet the applicability requirements of 40 CFR Part 60, Subpart Da? §60.40b(e) No §60.40b(f) No Has there been any changes at the existing unit for the sole purpose of combusting gases containing TRS (§60.281)? No Yes Does the affected facility meet the applicability requirements of and is subject to 40 CFR Part 60, Subparts Ea, Eb or AAAA? Yes §60.40b(h) Yes No Yes 12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09 The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. *** Below is a flowchart describing 40 CFR Part 60, Subpart Db. It will likely not be accessible using a screen reader. For the text of the statute/rule, please go to 40 CFR Part 60, Subpart Db (1 of 67)

Upload: trinhtram

Post on 17-Feb-2019

222 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

§60.40b(a)

Is the unit an

industrial-commercial-

institutional steam generating

unit with a heat input > 100 MMBtu/hr

that was constructed, modified,

or reconstructed after

06/19/1984?

End

40 CFR Part 60,

Subpart Db

does not apply.

Start

1

Does the

affected facility meet

the applicability requirements

of 40 CFR Part 60,

Subpart Da?

§60.40b(e)

No

§60.40b(f)

No

Has there

been any changes at

the existing unit for the sole

purpose of combusting gases

containing TRS

(§60.281)?

No

Yes

Does the

affected facility meet

the applicability requirements

of and is subject to 40 CFR Part

60, Subparts Ea, Eb

or AAAA?

Yes

§60.40b(h)

Yes

No

Yes

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Below is a flowchart describing 40 CFR Part 60, Subpart Db. It will likely not be accessible using a screen reader. For the text of the statute/rule, please go to

40 CFR Part 60, Subpart Db

(1 of 67)

Page 2: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

End

Is the unit a heat

recovery steam generator

subject to 40 CFR Part 60,

Subpart KKKK?

§60.40b(i)

Is the facility

covered by EPA approved

State or Federal section 111(d)/129

plan implementing 40 CFR Part 60,

Subpart Cb or Subpart

BBBB?

§60.40b(k)

Yes

Yes

Was

construction, modification,

or reconstruction on or before

6/19/86?

No

No

Yes

3

2

§60.40b(b)

1

No

40 CFR Part 60,

Subpart Db

does not apply.

40 CFR Part 60, Subpart Db(2 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 3: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Is the affected facility

a coal-fired unit with a heat input

capacity > 250 MMBtu/hour and meeting the

applicability requirements of 40 CFR

Part 60, Subpart D?

Yes

Comply with the PM,

Opacity, and NOx standards

of this Subpart. Comply with

the SO2 standards of 40 CFR

Part 60, Subpart D.

§60.40b(b)(2)

2

Comply with the NOx

standards of this Subpart.

§60.40b(b)(3)

Is the affected facility

an oil-fired unit with a heat input

capacity > 250 MMBtu/hour and meeting the

applicability requirements of 40 CFR

Part 60, Subpart D?

Comply with the NOx standards

of this Subpart. Comply with the

PM, Opacity, and SO2 standards

of 40 CFR Part 60, Subpart D.

§60.40b(b)(4)

Yes

No

Yes

34

No

18

Yes

Comply with the PM,

Opacity, and NOx standards

of this Subpart.

§60.40b(b)(1)

Is the

affected facility a

coal-fired unit with a heat input

capacity between 100 and

250 MMBtu/hour?

No

Is the

affected facility an

oil-fired unit with a heat input

capacity between 100 and

250 MMBtu/hour?

No

3

40 CFR Part 60, Subpart Db(3 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 4: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Does the affected

facility meet the applicability

requirements of 40 CFR Part

60, Subpart J?

Comply with the PM, Opacity, and

NOx standards of this Subpart.

Comply with the SO2 standards of

40 CFR Part 60, Subpart J.

§60.40b(c)

Yes

No

Does the affected

facility meet the applicability

requirements of 40 CFR Part

60, Subpart E?

Comply with the PM,

Opacity, and NOx standards

of this Subpart.

§60.40b(d)

Yes

3

4

No

18

40 CFR Part 60, Subpart Db(4 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 5: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

SO2

Is the

affected facility combusting

coal or oil, alone or in combination with

any other fuel, in a duct burner as part

of a combined cycle

system?

Does the

affected facility have a

federally enforceable requirement

limiting operation to an annual

capacity factor of < 30%

for coal and oil?

§60.42b(d)(1)

§60.42b(d)(3)

5

No

4

Yes

Is < 30%

of the heat input from

combustion of coal and oil

in the duct burner and > 70%

from the exhaust

gases?

§60.42b(d)(3)

No

No

Yes

Is

the affected

facility burning coke

oven gas alone or in combination

with natural gas or very low

sulfur distillate

oil?

§60.42b(d)(4)

6

Yes

No

7

Was

construction,

reconstruction or modification

on on or before

2/28/2005?

§60.42b(a)

No 10Yes

Yes

40 CFR Part 60, Subpart Db(5 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 6: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Comply with the following:

Standard

§60.42b(d)

§60.42b(e), (g)

§60.45b(a)

Monitoring/Testing

[T]§60.45b(b), (c), (c)(1), [T](e)

[T]§60.45b(f), (g), (h)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1)-(3), (b), (j)

§60.49b(k), (k)(1)-(3), (k)(5)-(6)

§60.49b(k)(11), (v), (w)

5 6

Comply with the following:

Standard

§60.42b(d)

§60.42b(e), (g)

§60.45b(a)

Monitoring/Testing

[T]§60.45b(b), (c), (c)(1), [T](f)

§60.45b(g), (h)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b)

§60.49b(j), (k), (k)(1)-(3), (k)(5)-(6)

§60.49b(k)(11), (v), (w)

Are SO2

emissions determined by

using as-fired fuel sampling

and analysis per

Method 19?§60.45b(c)(5)

Yes

No

12

Comply with the following:

Monitoring/Testing

[G]§60.45b(c)(4), (c)(5)

Comply with the following:

Monitoring/Testing

[G]§60.45b(c)(3), [G](c)(4)

Is the affected

facility combusting only

coal or only oil?

§60.45b(c)(2)

Yes

Comply with the following:

Monitoring/Testing

[G]§60.45b(c)(2)

No

40 CFR Part 60, Subpart Db(6 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 7: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

7

Does the

affected facility combust

coal or oil alone, or in combination

with any other fuel and use

emerging technology to

control SO2?

§60.42b(c)

No

Comply with the following:

Standard

§60.42b(c)

§60.42b(g), (i)

§60.45b(a)

Monitoring/Testing

§60.45b(i)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3)-(4)

§60.49b(j), (v), (w)

Is the

affected facility

combusting only very

low sulfur oil, natural gas, or a

mixture of these fuels with

any other fuels per

§60.45b(j)?

§60.45b(j)

8

11

Is the

affected facility using

fuel pretreatment to reduce

potential SO2

emissions?

§60.42b(h)

Yes

Comply with the following:

Standard

§60.42b(e), [G](h)

Monitoring/Testing

[T]§60.45b(b), (c), (c)(1), [T](f)

§60.45b(g), (h)

Reporting

§60.49b(b), [G](n)

No

Yes

Yes

Comply with the following:

Standard

§60.42b(e)

Monitoring/Testing

[T]§60.45b(b), (c), (c)(1), [T](f)

§60.45b(g), (h)

Reporting

§60.49b(b)

16

No

40 CFR Part 60, Subpart Db(7 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 8: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

8

Does the

affected facility combust

coal refuse alone in a

fluidized bed?

§60.42b(b)

No

Comply with the following:

Standard

§60.42b(b)

§60.42b(e), (g), (i)

§60.45b(a)

Monitoring/Testing

[T]§60.45b(b), (c), (c)(1), [G](c)(2)

[T]§60.45b(f), (g)-(i)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b), (j)

§60.49b(k), (k)(1)-(3), (k)(5)-(6)

§60.49b(k)(11), [G](n), (v), (w)

9

Yes

12

40 CFR Part 60, Subpart Db(8 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 9: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

40 CFR Part 60, Subpart Db(9 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

9

Does the

affected facility combust

coal or oil?

§60.42b(a)

Comply with the following:

Standard

§60.42b(a)

§60.42b(g), (i)

§60.45b(a)

Monitoring/Testing

§60.45b(i)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (j)

§60.49b(v), (w)

Yes

No

No

Comply with the following:

Standard

§60.40b(a)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3)

Yes

Comply with the following:

Standard

§60.42b(e)

Monitoring/Testing

[T]§60.45b(b), (c), (c)(1), [T](f)

§60.45b(g), (h)

Reporting

§60.49b(b), [G](n)

Is the

affected facility

combusting only very

low sulfur oil, natural gas, or a

mixture of these fuels with

any other fuels per

§60.45b(j)?

§60.45b(j)

18

11

16

Page 10: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

40 CFR Part 60, Subpart Db(10 of 67)

Does the

affected facility combust

coal or oil alone, or in combination

with any other fuel and use

emerging technology to

control SO2?

§60.42b(c)

Comply with the following:

Standard

§60.42b(c)

§60.42b(g), (i)

§60.45b(a)

Monitoring/Testing

§60.45b(i)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3)-(4)

§60.49b(j), (v), (w)

Is the

affected facility using

fuel pretreatment to reduce

potential SO2

emissions?

Yes

Comply with the following:

Standard

§60.42b(e), [G](h)

Monitoring/Testing

[T]§60.45b(b), (c), (c)(1), [T](f)

§60.45b(g), (h)

Reporting

§60.49b(b), [G](n)

No

Yes

Yes

Comply with the following:

Standard

§60.42b(e)

Monitoring/Testing

[T]§60.45b(b), (c), (c)(1), [T](f)

§60.45b(g), (h)

Reporting

§60.49b(b)

No

10

13No

Is the

affected facility

combusting only very

low sulfur oil, natural gas, or a

mixture of these fuels with

any other fuels per

§60.45b(j)?

§60.45b(j)

11

16

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 11: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Are fuel

receipts maintained per

§60.49b(r)(1)?

Comply with the following:

Standard

§60.42b(j)

Monitoring/Testing

§60.45b(j)

§60.47b(f)

Recordkeeping

§60.42b(j)(2)

Reporting

[G]§60.49b(m)

No

Comply with the following:

Standard

§60.42b(j)

Monitoring/Testing

§60.42b(j)(1)

Reporting

§60.49b(b)

15

11

Does the

affected facility have a

federally enforceable permit limiting

the annual capacity factor

to < 10%?

§60.42b(f)(1)

Comply with the following:

Standard

[G]§60.42b(f)

Monitoring/Testing

[G]§60.45b(d)

Reporting

§60.49b(a)(2), (l)

§60.49b(l)(1)-(2), (l)(4)-(5)

Comply with the following:

Standard

§60.42b(e)

Monitoring/Testing

§60.45b(c), (c)(1), [G](c)(2)

Reporting

§60.49b(k), (k)(1)-(3)

§60.49b(k)(5)-(6), (k)(11)

No

Is low sulfur

content demonstrated

by procedures in

§60.49b(r)?§60.42b(j)

Comply with the following:

Recordkeeping

§60.49b(r), [G](r)(2)

Reporting

§60.49b(r), [G](r)(2)

Comply with the following:

Recordkeeping

§60.49b(r), (r)(1)

Reporting

§60.49b(r), (r)(1)

Yes

Yes

§60.49b(r)(1)

Yes

No

18

12

40 CFR Part 60, Subpart Db(11 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 12: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Is the

affected facility operating

a continuous emission monitoring

system for measuring SO2

concentrations?

§60.47b(a)

Comply with the following:

Monitoring/Testing

[G]§60.47b(a), (c)-(d), [G](e)

Recordkeeping

[G]§60.47b(a)

Reporting

§60.49b(k)(4), (k)(8)-(10)

12

No

Yes

Comply with the following:

Monitoring/Testing

§60.47b(b), (b)(2)-(4)

Reporting

§60.49b(k)(7)

Are SO2

emissions determined by

using as-fired fuel sampling

and analysis per

Method 19?

No

Comply with the following:

Monitoring/Testing

§60.47b(b), (b)(1), (b)(3)-(4)

Reporting

§60.49b(k)(7)

Yes

§60.47b(b)(1)

18

40 CFR Part 60, Subpart Db(12 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 13: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

13

Does the

affected facility

combust coal, oil, gaseous

fuels, a mixture of these fuels, or

a mixture of these fuels

with any other

fuels?§60.42b(k)(1)

Yes

No

Comply with the following:

Standard

§60.40b(a)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3)

Yes

Comply with the following:

Standard

§60.42b(k)(2)

Monitoring/Testing

§60.47b(f)

Recordkeeping

§60.45b(k)

§60.49b(o)

Reporting

§60.49b(a), (a)(1)

§60.42b(k)(2)

No

Is the

affected facility

combusting very low sulfur

oil, gaseous fuel, a mixture of

these fuels, or a mixture of these fuels

with any other fuels of potential SO2

emission rate of 140 ng/J

(0.32lb/MMBtu)

or less?

Yes

No

Comply with the following:

Recordkeeping

§60.49b(r), (r)(1)

Reporting

§60.49b(r), (r)(1)

Comply with the following:

Recordkeeping

§60.49b(r), [G](r)(2)

Reporting

§60.49b(r), [G](r)(2)

14

Are fuel

receipts maintained per

§60.49b(r)(1)?

§60.42b(k)

§60.49b(r)(1)

18

40 CFR Part 60, Subpart Db(13 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 14: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

40 CFR Part 60, Subpart Db(14 of 67)

No

Is the §60.42b(k)(4)

alternative to §60.42b(k)(1)

being chosen?

§60.42b(k)(4)

Yes

14

§60.42b(k)(4)

Is the

affected facility

combusting coal or a mixture

of coal with other

fuels?

Yes

No

Comply with the following:

Standard

§60.42b(k)(1)

§60.42b(e), [G](f), (g)

§60.45b(a)

Monitoring/Testing

[T]§60.45b(b), (c), (c)(1), [T](f)

§60.45b(g)-(h)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b)

§60.49b(j), [G](n), (v), (w)

Comply with the following:

Standard

§60.42b(k)(4)

§60.42b(e), [G](f), (g)

§60.45b(a)

Monitoring/Testing

[T]§60.45b(b), (c), (c)(1), [T](f)

§60.45b(g)-(h)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b)

§60.49b(j), [G](n), (v), (w)

16

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 15: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

15

Is the

affected facility operating

a continuous emission monitoring

system for measuring SO2

concentrations?

§60.47b(a)

Comply with the following:

Monitoring/Testing

[G]§60.47b(a), (c)-(d), [G](e)

Recordkeeping

[G]§60.47b(a)

Reporting

§60.49b(b), (l)(3), (l)(7)-(9)

No

Yes

Comply with the following:

Monitoring/Testing

§60.47b(b), (b)(2)-(4)

Reporting

§60.49b(l)(6)

Comply with the following:

Monitoring/Testing

§60.47b(b), (b)(1), (b)(3)-(4)

Reporting

§60.49b(l)(6)

Yes

No

Will

as-fired fuel sampling and

analysis per Method 19 be

used?

§60.47b(b)(1)

18

40 CFR Part 60, Subpart Db(15 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 16: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

16

Is the affected facility

operating a CEMS for measuring

SO2 concentrations?

§60.47b(a)

Comply with the following:

Monitoring/Testing

[G]§60.47b(a), (c)-(d), [G](e)

Recordkeeping

[G]§60.47b(a)

Reporting

§60.49b(k), (k)(1)-(6), (k)(8)-(11)

Yes

Is

the affected

facility combusting coal or oil

with other

fuel?

§60.45b(c)(3)

Comply with the following:

Monitoring/Testing

[G]§60.45b(c)(3), [G](c)(4)

Comply with the following:

Monitoring/Testing

[G]§60.45b(c)(2)

No

17 18

Is the affected

facility combusting only coal

and/or oil?

Yes

§60.45b(c)(2)

No

YesNo

40 CFR Part 60, Subpart Db(16 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 17: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Will Method

6B sampling and analysis

be used?

§60.47b(b)(2)

Yes

Comply with the following:

Monitoring/Testing

§60.47b(b), (b)(1), (b)(3)-(4)

Reporting

§60.49b(k), (k)(1)-(3)

§60.49b(k)(5)-(7), (k)(11)

Comply with the following:

Monitoring/Testing

§60.47b(b), (b)(2)-(4)

Reporting

§60.49b(k), (k)(1)-(3)

§60.49b(k)(5)-(7), (k)(11)

17

No

18

40 CFR Part 60, Subpart Db(17 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 18: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

PM18

Was the

affected facility constructed,

reconstructed, or modified after

2/28/2005?

Yes

Yes

Is the affected

facility combusting only oil

containing no more than 0.3 weight

percent sulfur or coke oven gas alone or in

combination with other fuels not

subject to a particulate

matter standard?

Comply with the following:

Standard

§60.43b(h)(5)

[G]§60.48b(j)

Recordkeeping

§60.46b(i)

[G]§60.48b(j)

§60.49b(o)

Reporting

§60.49b(a), (a)(1)

No

Did the

affected facility commence

modification after

2/28/2005?

21

§60.43b(h)(1)

§60.43b(h)(5)

§60.43b(h)(2)

22

19No

Yes

Comply with the following:

Recordkeeping

§60.49b(r), (r)(1)

Reporting

§60.49b(r), (r)(1)

Comply with the following:

Recordkeeping

§60.49b(r), [G](r)(2)

Reporting

§60.49b(r), [G](r)(2)

Are fuel

receipts maintained per

§60.49b(r)(1)?

§60.46b(i)

§60.49b(r)(1)

No

No

Yes

34

40 CFR Part 60, Subpart Db(18 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 19: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

40 CFR Part 60, Subpart Db(19 of 67)

20

Is the facility

burning coke oven

gas alone or with fuels not

subject to PM, and not using

a post-combustion

technology?

Comply with the following:

Standard

§60.43b(a)(4)

Recordkeeping

§60.49b(o)

Reporting

§60.49b(a), (a)(1)§60.43b(a)(4)

19

Is the affected

facility combusting only coal or

coal with other fuels?

§60.43b(a)(3)

25

No

Yes

No

Yes 34

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 20: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

20

31

Is the

heat input capacity < 250

MMBtu/hr?

Does the

affected facility have a

federally enforceable requirement limiting

operation to an annual capacity factor of

< 30% for coal or coal and

other solid fuels?

Was

construction commenced

after 6/19/84 and before

11/25/86?

§60.43b(a)(3)(ii)

§60.43b(a)(3)(iii)

24

No

Is the

affected facility

combusting only coal or a

mixture of coal with other fuels, and has

an annual capacity factor for

the other fuels of 10%

or less? §60.43b(a)(1)

Comply with the following:

Standard

§60.43b(a)(1)

§60.43b(e), (g)

§60.46b(a)

Monitoring/Testing

§60.46b(b)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3)

32

No

Yes

Yes

§60.43b(a)(3)(iv)

Yes

Yes

No

No

40 CFR Part 60, Subpart Db(20 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 21: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

40 CFR Part 60, Subpart Db(21 of 67)

21

Does the affected

facility combust coal, oil,

wood, a mixture of these fuels, or a

mixture of these fuels with any

other fuels?

Comply with the following:

Standard

§60.40b(a)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3)

33

Comply with the following:

Standard

§60.43b(h)(1)

§60.43b(h)(1)

§60.43b(e), (g)

§60.46b(a)

Monitoring/Testing

§60.46b(b)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3)

NoYes

32

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 22: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

40 CFR Part 60, Subpart Db(22 of 67)

22

Does the

affected facility combust

over 30% wood by heat

input?

Yes

No 23

Comply with the following:

Standard

§60.43b(h)(4)

§60.43b(h)(4)

§60.43b(e), (g)

§60.46b(a)

Monitoring/Testing

§60.46b(b)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3)

Does the

affected facility have

a maximum heat input capacity

greater than 73 MW

(250 MMBtu/hr)?

§60.43b(h)(4)

Comply with the following:

Standard

§60.43b(h)(3)

§60.43b(e), (g)

§60.46b(a)

Monitoring/Testing

§60.46b(b)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3)

Yes No

32

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 23: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

40 CFR Part 60, Subpart Db(23 of 67)

23

Does the affected

facility combust coal, oil,

wood, a mixture of these fuels, or a

mixture of these fuels with

any other fuels?

No

Comply with the following:

Standard

§60.40b(a)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3)

Comply with the following:

Standard

§60.43b(h)(1)

§60.43b(h)(2)

§60.43b(e), (g)

§60.46b(a)

Monitoring/Testing

§60.46b(b)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3)

Is the

facility electing to use the

alternative requirements of

§60.43b(h)(2)?

Comply with the following:

Standard

[G]§60.43b(h)(2)

§60.43b(h)(2)

§60.43b(e), (g)

§60.46b(a)

Monitoring/Testing

§60.46b(b)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3)

NoYes

Yes

32

33

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 24: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Is the

affected facility

combusting coal and

other fuels, and have a federally

enforceable annual capacity

factor for the other

fuels > 10%?

Yes

§60.43b(a)(2)

Comply with the following:

Standard

§60.43b(a)(2)

§60.43b(e), (g)

§60.46b(a)

Monitoring/Testing

§60.46b(b)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1)-(3)

24

No

Is the

affected facility

combusting oil or mixtures

of oil with other fuels and uses a

conventional or emerging

technology to reduce

SO2?

Comply with the following:

Standard

§60.43b(b)

§60.43b(g)

§60.46b(a)

Monitoring/Testing

§60.46b(b)

Recordkeeping

[G]§60.49b(d), (o)

§60.43b(b) Reporting

§60.49b(a), (a)(1), (a)(3)

Yes

No

26

25

Is the affected

facility combusting wood

or wood with other fuels

(except coal)?

§60.43b(c)

Yes

27No

32

40 CFR Part 60, Subpart Db(24 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 25: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Comply with the following:

Standard

§60.43b(c)(1)

§60.43b(e), (g)

§60.46b(a)

Monitoring/Testing

§60.46b(b)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3)

26

Is the

heat input capacity < 250

MMBtu/hr?

Does the

affected facility have

a federally enforceable

requirement limiting operation

to an annual capacity

factor of < 30%

for wood?

§60.43b(c)(2)(ii)

§60.43b(c)(2)(iii)

Does the

affected facility

have an annual capacity

factor > 30% for

wood?

§60.43b(c)(1)

Yes

Comply with the following:

Standard

§60.43b(c)(2)

§60.43b(e), (g)

§60.46b(a)

Monitoring/Testing

§60.46b(b)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1)-(3)

No

No

Yes

No

Yes

32

27

40 CFR Part 60, Subpart Db(25 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 26: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Is the

affected facility

combusting municipal-type

solid waste alone or with

other fuels?

§60.43b(d)

27

Is the

heat input capacity < 250

MMBtu/hr?

Does the

affected facility have

a federally enforceable requirement

limiting fuel operation to an annual

capacity factor

of < 30%?

§60.43b(d)(2)(iii)

§60.43b(d)(2)(ii)

Yes

Yes

No

Was

construction commenced

after 6/19/84 and before

11/25/86?

§60.43b(d)(2)(iv)

Yes

No

No

28

28 29

Yes

No

Comply with the following:

Standard

§60.40b(a)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3)

33

40 CFR Part 60, Subpart Db(26 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 27: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Is the

affected facility combusting

only municipal-type solid

waste?

§60.43b(d)(1)(i)

Comply with the following:

Standard

§60.43b(d)(2)

§60.43b(e), (g)

§60.46b(a)

Monitoring/Testing

§60.46b(b)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1)-(3)

No

Does the

affected facility,

combusting mixtures of fuels,

have an annual capacity factor

of < 10% for the other

fuels?§60.43b(d)(1)(ii)

30Yes

28 29

Comply with the following:

Standard

§60.40b(a)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3)

No

Yes

32

33

40 CFR Part 60, Subpart Db(27 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 28: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

31

Comply with the following:

Standard

§60.43b(a)(3)

§60.43b(e), (g)

§60.46b(a)

Monitoring/Testing

§60.46b(b)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1)-(3)

Comply with the following:

Standard

§60.43b(d)(1)

§60.43b(e), (g)

§60.46b(a)

Monitoring/Testing

§60.46b(b)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3)

30

32

40 CFR Part 60, Subpart Db(28 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 29: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

40 CFR Part 60, Subpart Db(29 of 67)

32

Is the facility electing

to install, calibrate, maintain,

and operate a continuous emission

monitoring system?

Yes

No

Comply with the following:

Monitoring/Testing

[T][G]§60.46b(j)

§60.48b(k)

Recordkeeping

[G]§60.46b(j)

§60.48b(k)

Comply with the following:

Monitoring/Testing

[T]§60.46b(d), [T](d)(1)

[T][G]§60.46b(d)(2)

[T]§60.46b(d)(3)-(5)

[T][G]§60.46b(d)(6)

§60.46b(j)

33

Does

the affected facility

use a CEMS for monitoring

particulate

matter?

§60.43b(f)

Yes

Yes

Is the

facility subject to a

federally enforceable PM limit

of 0.030 lb/MMBtu

or less

No

No

§60.43b(f)

33A

33A

34

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 30: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Comply with the following:

Standard

§60.43b(f)

§60.43b(g)

§60.46b(a)

Monitoring/Testing

[T]§60.46b(d), [T](d)(7)

Recordkeeping

[G]§60.49b(d), [G](f), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b)

§60.49b(h), (h)(3), (v), (w)

Comply with the following:

Standard

§60.40b(a)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3)

33A

Does

the affected facility

combust coal, oil, wood,

or mixtures of these fuels

with any other

fuels?

Yes

No

§60.43b(f)

PM(Opacity)

Does

the affected

facility meet any of the

conditions in §60.48b(j)(1)-(6)

and not use a

COMS?§60.48b(j)

No

Comply with the following:

Monitoring/Testing

§60.48b(a), (e)

Recordkeeping

§60.48b(a)

Does

the affected facility

combust coal, wood, or

municipal-type solid

waste?

§60.48b(e)(1)Comply with the following:

Monitoring/Testing

§60.48b(e)(1)

Yes

No

Comply with the following:

Standard

[G]§60.48b(j)

Monitoring/Testing

§60.48b(a), [G](a)(1)-(2)

§60.48b(a)(3)

Recordkeeping

§60.48b(a), [G](a)(1)-(2)

§60.48b(a)(3)

[G]§60.48b(j)

Yes

34

40 CFR Part 60, Subpart Db(30 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 31: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Does the

affected facility combust

alone or in combination only natural

gas, distillate oil or residual oil with

a nitrogen content of

0.30% w or less?

§60.44b(j)(1)

Does

the affected facility

have a federally enforceable

requirement limiting operation to

firing natural gas, distillate oil and/or residual

oil with a nitrogen content of 0.30%

weight or less and an annual

capacity factor of

10% or less?

§60.44b(j)(2)

§60.44b(j)(3)

Does the

affected facility

have a heat input capacity

of 250 MMBtu/hr

or less?§60.44b(k)

Comply with the following:

Standard

§60.40b(a)

Monitoring/Testing

[T]§60.46b(g)

Recordkeeping

[G]§60.49b(d), (o), [G](p)

Reporting

§60.49b(a), (a)(1)-(3), (q)

§60.49b(q)(1), (q)(3), (w)

36

42

No 68

34 NOx

No

Yes

Yes

Did the

affected facility

commence construction or

reconstruction after

7/9/97?§60.44b(l)

No

46

Yes

No

Yes

40 CFR Part 60, Subpart Db(31 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 32: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

36

Does the affected

facility combust only

oil or natural gas?

§60.44b(a)

Yes

37

No

Comply with the following:

Standard

§60.44b(b)

[G]§60.44b(j)

§60.46b(a)

Monitoring/Testing

§60.46b(c), [T](g), [G](h)

Recordkeeping

[G]§60.49b(d), (o), [G](p)

Reporting

§60.49b(a), (a)(1)-(3), (b), (q)

§60.49b(q)(1), (q)(3), (w)

Yes

Did the

affected facility

commence construction or

reconstruction after

7/9/97?

§60.44b(l)

No

40

Is the

affected facility

a duct burner used in

combined cycle

system?

§60.46b(f)62

35

NoYes

68

40 CFR Part 60, Subpart Db(32 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 33: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

40 CFR Part 60, Subpart Db(33 of 67)

Is the

affected facility a duct

burner?

§60.44b(a)(4)(i) Comply with the following:

Standard

§60.44b(a)(4)(ii)

[G]§60.44b(j)

§60.46b(a)

Monitoring/Testing

§60.46b(c), [T](g), [G](h)

Recordkeeping

[G]§60.49b(d), (o), [G](p)

Reporting

§60.49b(a), (a)(1)-(3), (b), (q)

§60.49b(q)(1)-(3), (w)

No

Is the

residual oil sampled

and analyzed for nitrogen

content as specified in

§60.49b(e)?

Comply with the following:

Monitoring/Testing

§60.46b(e)(4)

§60.49b(e)

Recordkeeping

§60.49b(e)

Comply with the following:

Monitoring/Testing

§60.46b(e)(2)

§60.49b(e)

§60.46b(e)(5)

72

No

Yes

37

Yes

Does the

affected facility combust

residual oil?

§60.44b(a)(4)(i)

Yes

No

Comply with the following:

Standard

§60.44b(a)(4)(i)

[G]§60.44b(j)

§60.46b(a)

Monitoring/Testing

§60.46b(c), [T](g), [G](h)

Recordkeeping

[G]§60.49b(d), (o), [G](p)

Reporting

§60.49b(a), (a)(1)-(3), (b), (q)

§60.49b(q)(1), (q)(3), (w)

38

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 34: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

40 CFR Part 60, Subpart Db(34 of 67)

38

Does

the affected

facility combust natural

gas or distillate oil with a

low heat release

rate?

§60.44b(a)(1)(i)

Comply with the following:

Standard

§60.44b(a)(1)(i)

[G]§60.44b(j)

§60.46b(a)

Monitoring/Testing

§60.46b(c), [T](g), [G](h)

Recordkeeping

[G]§60.49b(d), (o), [G](p)

Reporting

§60.49b(a), (a)(1)-(3), (b), (q)

§60.49b(q)(1), (q)(3), (w)

No

Yes

Does

the affected

facility combust natural

gas or distillate oil with a

high heat release

rate?

§60.44b(a)(1)(ii)

No

Yes

Comply with the following:

Standard

§60.44b(a)(1)(ii)

[G]§60.44b(j)

§60.46b(a)

Monitoring/Testing

§60.46b(c), [T](g), [G](h)

Recordkeeping

[G]§60.49b(d), (o), [G](p)

Reporting

§60.49b(a), (a)(1)-(3), (b), (q)

§60.49b(q)(1), (q)(3), (w)

39

72

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 35: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Does

the affected

facility combust residual

oil with a low heat

release rate?

§60.44b(a)(2)(i)

39Comply with the following:

Standard

§60.44b(a)(2)(i)

[G]§60.44b(j)

§60.46b(a)

Monitoring/Testing

§60.46b(c), [T](g), [G](h)

Recordkeeping

[G]§60.49b(d), (o), [G](p)

Reporting

§60.49b(a), (a)(1)-(3), (b)

§60.49b(q), (q)(1)-(3), (w)

Comply with the following:

Standard

§60.44b(a)(2)(ii)

[G]§60.44b(j)

§60.46b(a)

Monitoring/Testing

§60.46b(c), [T](g), [G](h)

Recordkeeping

[G]§60.49b(d), (o), [G](p)

Reporting

§60.49b(a), (a)(1)-(3), (b)

§60.49b(q), (q)(1)-(3), (w)

Yes

No

Is the

residual oil sampled

and analyzed for nitrogen

content as specified in

§60.49b(e)?

Comply with the following:

Monitoring/Testing

§60.46b(e)(4)

§60.49b(e)

Recordkeeping

§60.49b(e)

Comply with the following: §60.49b(e)Monitoring/Testing §60.46b(e)(5)

§60.46b(e)(2)

No

Yes

72

40 CFR Part 60, Subpart Db(35 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 36: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

40 CFR Part 60, Subpart Db(36 of 67)

40

§60.44b(l)(3)

Comply with the following:

Standard

§60.44b(l)(3)

§60.44b(h), (i), [G](j)

§60.46b(a)

Monitoring/Testing

§60.48Da(i)

Recordkeeping

[G]§60.49b(d), (o), [G](p)

Reporting

§60.49b(a), (a)(1), (a)(3), (b), (w)

Is the affected

facility choosing to comply

with the output based limit

in §60.44b(l)(3)?

Is more than

10% of the total annual

output electrical or

mechanical?

Yes

41

§60.49Da(c)(2)

Is the CEMS

complying with the requirements

of 40 CFR Part 75?

Yes

Comply with the following:

Monitoring/Testing

§60.49Da(c)(1)

Recordkeeping

[G]§60.49b(g)

Comply with the following:

Monitoring/Testing

§60.49Da(c)(2)

Reporting

§60.51Da(a), [G](b), (f), [G](h)

§60.51Da(j), (k)

43

§60.44b(l)(3)

No

No

NoYes

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 37: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

40 CFR Part 60, Subpart Db(37 of 67)

§60.44b(l)(2)

No

Does the

affected facility have low heat

release rate and combust natural gas or

distillate oil in excess of 30% of the heat

input from the combustion

of all fuels?

Yes

41

Is the affected facility

a duct burner used in combined

cycle system?

§60.46b(f)

Yes 59

No

58

35

Comply with the following:

Standard

§60.44b(l)(2)

[G]§60.44b(j)

§60.46b(a)

Monitoring/Testing

§60.46b(c), [T](g)

Recordkeeping

[G]§60.49b(d), (o), [G](p)

Reporting

§60.49b(a), (a)(1)-(3), (b), (q)

§60.49b(q)(1), (q)(3), (w)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 38: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

40 CFR Part 60, Subpart Db(38 of 67)

42

§60.44b(l)(3)

Comply with the following:

Standard

§60.44b(l)(3)

§60.44b(h), (i)

§60.46b(a)

Monitoring/Testing

§60.48Da(i)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b), (w)

Is the affected

facility choosing to comply

with the output based limit

in §60.44b(l)(3)?

Is more than

10% of the total annual

output electrical or

mechanical?

No

Yes

44

§60.44b(l)(3)

Is the CEMS

complying with the requirements of

40 CFR Part 75?

Yes

Comply with the following:

Monitoring/Testing

§60.49Da(c)(1)

Recordkeeping

[G]§60.49b(g)

Comply with the following:

Monitoring/Testing

§60.49Da(c)(2)

Reporting

§60.51Da(a), [G](b), (f), [G](h)

§60.51Da(j), (k)

43

No

No

§60.44b(l)(3)

Yes

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 39: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Comply with the following:

Monitoring/Testing

§60.49Da(k), (k)(2)

Is the

facility gas- or oil-fired

using §60.49Da(n)

alternative?

Comply with the following:

Monitoring/Testing

§60.49Da(n)

Yes

§60.49Da(n)

No

Is the

facility using §60.49Da(m)

alternative?

§60.49Da(m)

Comply with the following:

Monitoring/Testing

§60.49Da(m)

Yes

Comply with the following:

Monitoring/Testing

§60.49Da(l)

No

Does the

facility generate process

steam in combination with

electricity?

Comply with the following:

Monitoring/Testing

§60.49Da(k), (k)(3)

Yes

§60.49Da(k)(3)

Does the

affected facility generate

electricity only?

§60.49Da(k)(1)

Comply with the following:

Monitoring/Testing

§60.49Da(k), (k)(1)

Yes

No

No

72

43

40 CFR Part 60, Subpart Db(39 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 40: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

40 CFR Part 60, Subpart Db(40 of 67)

Does the

facility have an ACF

of 10% for coal, oil or natural gas,

and is it subject to a federally enforceable

requirement limiting the ACF

to 10% or less for these

fuels?

Comply with the following:

Standard

§60.44b(l)(1)

§60.44b(h), (i)

§60.46b(a)

Monitoring/Testing

§60.46b(c)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b)

No

§60.44b(l)(1)

Yes

§60.44b(l)(2)

Comply with the following:

Standard

§60.44b(l)(2)

§60.44b(h), (i)

§60.46b(a)

Monitoring/Testing

§60.46b(c)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b)No

Does the affected

facility have low heat release rate and

combust natural gas or distillate oil in excess

of 30% of the heat input from the

combustion of all fuels?

45

Yes

44

46

Does the

affected facility

combust coal, oil or

natural gas, or a mixture of these

fuels, or a mixture of these

fuels with other

fuels?

No

§60.44b(l)(1)

Yes

46

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 41: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

45

Does

the affected

facility combust natural

gas or distillate oil alone in combination

with fuels other than coal

or residual

oil?

60Yes

§60.46b(e)(4)

Does the

affected facility

simultaneously combust mixtures of

natural gas, oil,

or coal?

63

65

Yes

§60.46b(e)(4)

No

No

40 CFR Part 60, Subpart Db(41 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 42: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

40 CFR Part 60, Subpart Db(42 of 67)

Does the

affected facility

simultaneously combust natural gas

with wood, municipal-type solid

waste, or other solid fuel,

except coal?

§60.44b(d)

Does the

affected facility

simultaneously combust coal, oil, or

natural gas with byproduct/

waste?

§60.44b(e)

49

48

50

Yes

Yes

No

Does the affected

facility combust only coal,

oil, or natural gas?

§60.44b(a)

No

47

Does

the affected

facility simultaneously

combust mixtures of

natural gas, oil, or

coal?

56

§60.44b(b)

No

Yes

Yes

No

46

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 43: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Yes

Is the facility

subject to a federally

enforceable requirement limiting

the annual capacity factor for

natural gas to 10%

or less?

§60.44b(d)

Comply with the following:

Standard

§60.40b(a)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1)-(3)

Is the

facility subject

to a federally enforceable

requirement limiting the annual

capacity for coal, oil, and

natural gas to 10% §60.44b(e)or less?

4948

55

54

Yes

Comply with the following:

Standard

§60.44b(b)

§60.44b(h), (i)

§60.46b(a)

Monitoring/Testing

§60.46b(c)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b)

64

47

No

No

72

40 CFR Part 60, Subpart Db(43 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 44: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

50

No

67

Is the

affected facility a duct

burner in a combined cycle

system combusting natural

gas or distillate

oil?

Comply with the following:

Standard

§60.44b(a)(4)(i)

§60.44b(h), (i)

§60.46b(a)

Monitoring/Testing

§60.46b(c), [T](f)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b)

Yes

§60.44b(a)(1)(i)

Does

the affected

facility combust natural

gas or distillate oil with a

low heat release

rate?

61

Comply with the following:

Standard

§60.44b(a)(1)(i)

§60.44b(h), (i)

§60.46b(a)

Monitoring/Testing

§60.46b(c)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b)

Yes

No

Comply with the following:

Standard

§60.44b(a)(4)(ii)

§60.44b(h), (i)

§60.46b(a)

Monitoring/Testing

§60.46b(c), [T](f)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b)

Is the

affected facility a duct

burner in a combined cycle

system combusting

residual oil?

§60.44b(a)(4)(ii)

51

Yes 69

§60.44b(a)(4)(i)

No

40 CFR Part 60, Subpart Db(44 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 45: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Does

the affected

facility combust residual

oil with a low heat

release rate?

§60.44b(a)(2)(i)

Comply with the following:

Standard

§60.44b(a)(2)(i)

§60.44b(h), (i)

§60.46b(a)

Monitoring/Testing

§60.46b(c)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b)

51

Does

the affected

facility combust residual

oil with a high heat

release rate?

§60.44b(a)(2)(ii)

Comply with the following:

Standard

§60.44b(a)(2)(ii)

§60.44b(h), (i)

§60.46b(a)

Monitoring/Testing

§60.46b(c)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b)

No

Yes

No

52

Yes

70

Does

the affected

facility combust natural

gas or distillate oil with a

high heat release

rate?

§60.44b(a)(1)(ii)

Comply with the following:

Standard

§60.44b(a)(1)(ii)

§60.44b(h), (i)

§60.46b(a)

Monitoring/Testing

§60.46b(c)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b)No

Yes 61

40 CFR Part 60, Subpart Db(45 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 46: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

52

53

Does the

affected facility

combust coal in a spreader

stoker and fluidized

bed?§60.44b(a)(3)(ii)

Comply with the following:

Standard

§60.44b(a)(3)(ii)

§60.44b(h), (i)

§60.46b(a)

Monitoring/Testing

§60.46b(c), [T](e), [T](e)(1)

§60.46b(e)(2)

[G]§60.48b(b), (c)-(e), [G](e)(2), (e)(3), (f)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(d), [G](g), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b)

§60.49b(i), (v), (w)

Yes

Does the

affected facility combust

pulverized coal?

§60.44b(a)(3)(iii)

Comply with the following:

Standard

§60.44b(a)(3)(iii)

§60.44b(h), (i)

§60.46b(a)

Monitoring/Testing

§60.46b(c), [T](e), [T](e)(1)

§60.46b(e)(2)

[G]§60.48b(b), (c)-(e), [G](e)(2), (e)(3), (f)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(d), [G](g), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b)

§60.49b(i), (v), (w)

No

No

Does

the affected

facility combust coal and

have a mass-feed

stoker?§60.44b(a)(3)(i)

Comply with the following:

Standard

§60.44b(a)(3)(i)

§60.44b(h), (i)

§60.46b(a)

Monitoring/Testing

§60.46b(c), [T](e), [T](e)(1), (e)(2)

[G]§60.48b(b), (c)-(e), [G](e)(2), (e)(3), (f)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(d), [G](g), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b)

§60.49b(i), (v), (w)

Yes

No

Yes

72

40 CFR Part 60, Subpart Db(46 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 47: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

53

Does

the affected

facility combust

lignite?

§60.44b(a)(3)(iv)

Comply with the following:

Standard

§60.44b(a)(3)(iv)

§60.44b(h), (i)

§60.46b(a)

Monitoring/Testing

§60.46b(c), [T](e), [T](e)(1), (e)(2)

[G]§60.48b(b), (c)-(e), [G](e)(2), (e)(3), (f)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(d), [G](g), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b)

§60.49b(i), (v), (w)

Yes

Comply with the following:

Standard

§60.44b(a)(3)(vi)

§60.44b(h), (i)

§60.46b(a)

Monitoring/Testing

§60.46b(c), [T](e), [T](e)(1), (e)(2)

[G]§60.48b(b), (c)-(e), [G](e)(2), (e)(3), (f)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(d), [G](g), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b)

§60.49b(i), (v), (w)

Does

the affected

facility combust lignite

mined in ND, SD, or MT

in a slag tap

furnace?

§60.44b(a)(3)(v)

Comply with the following:

Standard

§60.44b(a)(3)(v)

§60.44b(h), (i)

§60.46b(a)

Monitoring/Testing

§60.46b(c), [T](e), [T](e)(1), (e)(2)

[G]§60.48b(b), (c)-(e), [G](e)(2), (e)(3), (f)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(d), [G](g), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b)

§60.49b(i), (v), (w)

No

Yes

These requirements are

for a facility that

combusts coal-derived

synthetic fuels.

No

72

40 CFR Part 60, Subpart Db(47 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 48: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

54

Comply with the following:

Standard

§60.44b(e)

§60.44b(h), (i)

§60.46b(a)

Monitoring/Testing

§60.46b(c), [T](e), [T](e)(1)

[G]§60.48b(b), (c)-(e), [G](e)(2)

§60.48b(e)(3), (f)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(d), [G](g), (o)

Reporting

§60.49b(a), (a)(1)-(3)

§60.49b(b), (i), (v), (w)

55Comply with the following:

Standard

§60.44b(d)

§60.44b(h), (i)

§60.46b(a)

Monitoring/Testing

§60.46b(c), [T](e), [T](e)(1)

[G]§60.48b(b), (c)-(e), [G](e)(2)

§60.48b(e)(3), (f)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(d), [G](g), (o)

Reporting

§60.49b(a), (a)(1)-(3)

§60.49b(b), (i), (v), (w)Does the

affected facility

combust byproduct/waste with

natural gas or oil and petitioning the

Administrator to establish

emission limits for the

facility?

Comply with the following:

Standard

§60.44b(f)

[G]§60.44b(f)(1), (f)(2), (h), (i)

§60.46b(a)

Monitoring/Testing

§60.46b(c), [T](e), [T](e)(1)

[G]§60.48b(b), (c)-(e)

[G]§60.48b(e)(2), (e)(3), (f)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(d), [G](g), (o)

Reporting

§60.49b(a), (a)(1), (a)(3)

§60.49b(b), (i), (v), (w)

§60.44b(e)

Yes

No

72

72

40 CFR Part 60, Subpart Db(48 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 49: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

56

Does the affected

facility combust hazardous waste

with natural gas or oil?

§60.44b(g)

Comply with the following:

Standard

§60.44b(g)

§60.44b(h), (i)

§60.46b(a)

Monitoring/Testing

§60.46b(c), [T](e), [T](e)(1)

[G]§60.48b(b), (c)-(e)

[G]§60.48b(e)(2), (e)(3), (f)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(d), [G](g), (o)

Reporting

§60.49b(a), (a)(1), (a)(3)

§60.49b(b), (i), (v), (w)

Yes

No

Comply with the following:

Standard

§60.40b(a)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3)

Does the

affected facility

simultaneously combust coal or

oil, or a mixture of these fuels with natural

gas, and wood, municipal-type

solid waste, or any

other fuel?

§60.44b(c)

57

Yes

No

72

40 CFR Part 60, Subpart Db(49 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 50: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

40 CFR Part 60, Subpart Db(50 of 67)

Comply with the following:

Standard

§60.44b(b)*

§60.44b(h), (i)

§60.46b(a)

Monitoring/Testing

§60.46b(c)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1), (a)(3), (b)

Is the

facility subject to a

federally enforceable requirement

limiting the annual capacity factor for

coal or oil, or mixture of these

fuels with natural gas to

10%or less?§60.44b(c)

57

Comply with the following:

Standard

§60.40b(a)

Recordkeeping

[G]§60.49b(d), (o)

Reporting

§60.49b(a), (a)(1)-(3)

YesNo

7264

* A facility that simultaneously combusts the fuels specified in §60.44b(c) has an option to use

the emission limitations of §60.44b(a) or (b). To simplify the flowchart only the emission

limitation of §60.44b(b) is used because when fuels are simultaneously combusted the emission

limits of paragraph (a) are used to calculate the limit in paragraph (b). Also the emission

limitations will be the same for either §60.44b(a) or §60.44b(b).

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 51: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

40 CFR Part 60, Subpart Db(51 of 67)

Does

the affected facility

combust residual

oil?

§60.49b(e)

Comply with the following:

Monitoring/Testing

[G]§60.46b(h)

5958

Is the affected

facility electing to conduct

the performance test per

§60.46b(f)(1)?

§60.46b(f)(1)

Yes

Comply with the following:

Standard

§60.48b(h)

Monitoring/Testing

§60.46b(f), [T][G](f)(1)

Comply with the following:

Monitoring/Testing

§60.46b(f), (f)(2)

[G]§60.48b(b), (c)-(d), (e)

[G]§60.48b(e)(2), (e)(3), (f)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(g)

No

Comply with the following:

Monitoring/Testing

§60.49b(e)

Recordkeeping

§60.49b(e)

Reporting

§60.49b(q)(2)

Yes

No

72

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 52: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

40 CFR Part 60, Subpart Db(52 of 67)

Is the affected

facility electing to conduct

the performance test per

§60.46b(f)(1)?§60.46b(f)(1)

Comply with the following:

Standard

§60.48b(h)

Monitoring/Testing

§60.46b(f), [T][G](f)(1)

Recordkeeping

[G]§60.49b(p)

Comply with the following:

Monitoring/Testing

§60.46b(f), (f)(2)

[G]§60.48b(b), (c)-(e)

[G]§60.48b(e)(2), (e)(3), (f)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(g)

No

Is the affected facility

a duct burner used in combined

cycle system?

§60.46b(f)

60

Yes

Yes

No

72

61

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 53: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

61

Does the

affected facility

have a heat input of 250

MMBtu/hr

or less?

§60.46b(e)(4)

Does the

affected facility use

a CEMS?

§60.46b(e)

Comply with the following:

Monitoring/Testing

[T]§60.46b(e), [T](e)(1), (e)(3)

[G]§60.48b(b), (c)-(e)

[G]§60.48b(e)(2), (e)(3), (f)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(g)

Reporting

§60.49b(h), (i), (v), (w)

No

Comply with the following:

Monitoring/Testing

[T]§60.46b(e), [T](e)(1), (e)(4)

[G]§60.48b(b), (c)-(e)

[G]§60.48b(e)(2), (e)(3)

§60.48b(f), (g)(1)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(g)

Reporting

§60.49b(h), (h)(4), (i), (v), (w)Comply with the following:

Monitoring/Testing

§60.48b(g)(2)

Recordkeeping

[G]§60.49b(c), [G](g)

Reporting

[G]§60.49b(c), (h), (v), (w)

Yes

No

Yes

72

40 CFR Part 60, Subpart Db(53 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 54: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

71

Is the affected

facility electing to conduct

the performance test per

§60.46b(f)(1)?§60.46b(f)(1)

Yes

Comply with the following:

Standard

§60.48b(h)

Monitoring/Testing

§60.46b(f), [T][G](f)(1)

Comply with the following:

Monitoring/Testing

§60.46b(f), (f)(2)

[G]§60.48b(b), (c)-(e)

[G]§60.48b(e)(2), (e)(3), (f)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(g)

Is the

affected facility

a duct burner used in

combined cycle

system? §60.46b(f)

No

62

Yes

63

Is the affected

facility electing to conduct

the performance test per

§60.46b(f)(1)?

§60.46b(f)(1)

Comply with the following:

Standard

§60.48b(h)

Monitoring/Testing

§60.46b(f), [T][G](f)(1)

Comply with the following:

Monitoring/Testing

§60.46b(f), (f)(2)

[G]§60.48b(b), (c)-(e)

[G]§60.48b(e)(2), (e)(3), (f)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(g)

No

Yes

No

68

64

40 CFR Part 60, Subpart Db(54 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 55: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Does the

affected facility

have a heat input of 250

MMBtu/hr or

less?

§60.46b(e)(4)

No

Comply with the following:

Monitoring/Testing

[T]§60.46b(e), [T](e)(1)

[G]§60.48b(b), (c)-(e)

[G]§60.48b(e)(2), (e)(3), (f)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(g)

Reporting

§60.49b(i), (v), (w)

Comply with the following:

Monitoring/Testing

§60.48b(g)(2)

Recordkeeping

[G]§60.49b(c), [G](g)

Reporting

[G]§60.49b(c), (h), (v), (w)

Does the

affected facility use a

CEMS?

§60.46b(e)

Comply with the following:

Monitoring/Testing

[T]§60.46b(e), [T](e)(1), (e)(4)

[G]§60.48b(b), (c)-(e)

[G]§60.48b(e)(2), (e)(3), (f), (g)(1)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(g)

Reporting

§60.49b(h), (h)(4), (i), (v), (w)

Yes

Is the

residual oil sampled

and analyzed for nitrogen

content as specified in

§60.49b(e)?

Comply with the following:

Monitoring/Testing

§60.46b(e)(4)

§60.49b(e)

Recordkeeping

§60.49b(e) §60.49b(e)

§60.46b(e)(5)

Comply with the following:

Monitoring/Testing

§60.46b(e)(2)

Does the

affected facility combust

residual oil?

§60.49b(e)

Yes

Yes

No

No

Yes

No

72

72

64

71

40 CFR Part 60, Subpart Db(55 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 56: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Is the affected

facility electing to conduct

the performance test per

§60.46b(f)(1)?

§60.46b(f)(1)

Yes

Comply with the following:

Standard

§60.48b(h)

Monitoring/Testing

§60.46b(f), [T][G](f)(1)

Comply with the following:

Monitoring/Testing

§60.46b(f), (f)(2)

[G]§60.48b(b), (c)-(e)

[G]§60.48b(e)(2), (e)(3), (f)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(g)

65

Is the affected facility

a duct burner used in combined

cycle system?

§60.46b(f)

No 66

No

Yes

71

40 CFR Part 60, Subpart Db(56 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 57: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Does the

affected facility have a heat

input of 250MMBtu/hr or

less?

§60.46b(e)(4)

Does the

affected facility use a

CEMS?

§60.46b(e)Comply with the following:

Monitoring/Testing

[T]§60.46b(e), [T](e)(1), [T](e)(4)

[G]§60.48b(b), (c)-(e)

[G]§60.48b(e)(2), (e)(3)

§60.48b(f), (g)(1)

§60.49b(e)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(g)

Reporting

§60.49b(h), (h)(4), (i), (v), (w)

Comply with the following:

Monitoring/Testing

§60.48b(g)(2)

Recordkeeping

[G]§60.49b(c), [G](g)

Reporting

[G]§60.49b(c), (h), (v), (w)

Yes

Yes

66

Does the

affected facility combust

coal?

No

§60.46b(e)(2)

Comply with the following:

Monitoring/Testing

§60.46b(e)(2)

Yes

No

No

Comply with the following:

Monitoring/Testing

[T]§60.46b(e), [T](e)(1), (e)(3)

[G]§60.48b(b), (c)-(e)

[G]§60.48b(e)(2), (e)(3), (f)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(g)

Reporting

§60.49b(h), (i), (v), (w)

71

71

40 CFR Part 60, Subpart Db(57 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 58: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

40 CFR Part 60, Subpart Db(58 of 67)

Is the affected

facility electing to conduct

the performance test per

§60.46b(f)(1)?

§60.46b(f)(1)

No

Comply with the following:

Standard

§60.48b(h)

Monitoring/Testing

[T][G]§60.46b(f)(1)

Comply with the following:

Monitoring/Testing

§60.46b(f)(2)

[G]§60.48b(b), (c)-(e)

[G]§60.48b(e)(2), (e)(3), (f)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(g)

67

Yes

No

Does the

affected facility

combust residual oil with a nitrogen

content < 0.30 weight

percent?

Comply with the following:

Monitoring/Testing

§60.49b(e)

Recordkeeping

§60.49b(e)

Reporting

§60.49b(q)(2)

68

§60.49b(e)

Yes

72

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 59: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

40 CFR Part 60, Subpart Db(59 of 67)

Is the affected

facility electing to conduct

the performance test per

§60.46b(f)(1)?

§60.46b(f)(1)

Comply with the following:

Standard

§60.48b(h)

Monitoring/Testing

[T][G]§60.46b(f)(1)

Comply with the following:

Monitoring/Testing

§60.46b(f)(2)

[G]§60.48b(b), (c)-(e)

[G]§60.48b(e)(2), (e)(3), (f)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(g)

69

Is the

residual oil sampled

and analyzed for nitrogen

content as specified in

§60.49b(e)?

Comply with the following:

Monitoring/Testing

§60.46b(e)(4)

§60.49b(e)

Recordkeeping

§60.49b(e)

Comply with the following:

Monitoring/Testing

§60.46b(e)(2)

§60.49b(e)

§60.46b(e)(5)

No

Does the

residual oil have a nitrogen

content greater than 0.30 %

by weight?

§60.46b(e)(2)

No Yes

YesNo

Yes 72

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 60: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

70

Does

the affected facility

have a heat input of 250

MMBtu/hr or

less?§60.46b(e)(4)

Does the

affected facility use

a CEMS?

§60.46b(e)

Comply with the following:

Monitoring/Testing

[T]§60.46b(e), [T](e)(1), (e)(3)

[G]§60.48b(b), (c)-(e)

[G]§60.48b(e)(2), (e)(3), (f)

Recordkeeping

[G]§60.48b(b), (c)

[G]§60.49b(g)

Reporting

§60.49b(h), (i), (v), (w)

No

Comply with the following:

Monitoring/Testing

[T]§60.46b(e), [T](e)(1), (e)(4)

[G]§60.48b(b), (c)-(e)

[G]§60.48b(e)(2), (e)(3), (f), (g)(1)

§60.49b(e)

Recordkeeping

[G]§60.48b(b), (c)

§60.49b(e), [G](g)

Reporting

§60.49b(h), (h)(4), (i), (v), (w)

Comply with the following:

Monitoring/Testing

§60.48b(g)(2)

Recordkeeping

[G]§60.49b(c), [G](g)

Reporting

[G]§60.49b(c), (h), (v), (w)

Yes

No

Yes

72

40 CFR Part 60, Subpart Db(60 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 61: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Comply with the following:

Monitoring/Testing

§60.49b(e)

Recordkeeping

§60.49b(e)

Does the

affected facility combust

residual oil?

§60.49b(e)

No

Yes

71

72

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

40 CFR Part 60, Subpart Db(61 of 67)

Page 62: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Is the affected facility

a coal-fired unit with a heat input

capacity > 250 MMBtu/hour and meet the

applicability requirements of 40 CFR

Part 60, Subpart D?

Yes

§60.40b(b)(2)

No

72

Is the affected facility

an oil-fired unit with a heat input

capacity > 250 MMBtu/hour and meet the

applicability requirements of 40 CFR

Part 60, Subpart D?

§60.40b(b)(4)

Yes 73

No

Does the affected

facility meet the applicability

requirements of 40 CFR Part

60, Subpart J?

§60.40b(c)

Yes 76End No

74

40 CFR Part 60, Subpart Db(62 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 63: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Is the affected

facility the Southwestern

Public Service Company's

Harrington Station #1, in

Amarillo?

73

§60.42(b)(1)

Comply with the following:

Standard

§60.42(b)(1)

Monitoring/Testing

§60.45(g), (g)(1)(i)

[T]§60.46(a), [T](b)(3)

Reporting

§60.45(g)

74

Comply with the following:

Standard

§60.42(a)(1)

Monitoring/Testing

[T]§60.46(a), [T](b)(1), [T][G](b)(2)

[T][G]§60.46(d)(1), [T](d)(2)

[T][G]§60.46(d)(3), [T](d)(6)-(7)

Comply with the following:

Standard

§60.42(a)(2)

Monitoring/Testing

§60.45(g), (g)(1)

[T]§60.46(a), [T](b)(3)

Reporting

§60.45(g)

Comply with the following:

Monitoring/Testing

§60.45(a), (c), (c)(5)

Is the

affected facility

combusting fossil fuel

and nonfossil

fuel?§60.45(c)(5)

Comply with the following:

Monitoring/Testing

§60.45(a), (c), (c)(3)

Yes

PM(Opacity)

No

NoYes

All of the following

requirements have been

taken from 40 CFR Part

60, Subpart D

PM

40 CFR Part 60, Subpart Db(63 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 64: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

74

§60.45(b)(1)

Is

the affected

facility combusting only

gaseous fossil

fuel?

Is

the affected

facility combusting liquid

fossil fuel or liquid fossil fuel

and wood residue?

No

§60.43(a)(1)

Yes

75

Comply with the following:

Standard

§60.43(a)(1)

Monitoring/Testing

[T]§60.46(a), [T](b)(1)

[T][G]§60.46(b)(4), [T][G](d)(1)

[T][G]§60.46(d)(3), [T](d)(4)

[T]§60.46(d)(6)-(7)

Is the

affected facility

combusting solid fossil fuel or

solid fossil fuel and wood

residue?

§60.43(a)(2)

Comply with the following:

Standard

§60.43(a)(2)

Monitoring/Testing

[T]§60.46(a), [T](b)(1)

[T][G]§60.46(b)(4), [T][G](d)(1)

[T][G]§60.46(d)(3), [T](d)(4)

[T]§60.46(d)(6)-(7)

Yes

Yes

Comply with the following:

Standard

§60.43(b)

§60.43(c)

Monitoring/Testing

[T]§60.46(a), [T](b)(1)

[T][G]§60.46(b)(4), [T][G](c)

[T][G]§60.46(d)(1), [T][G](d)(3)

[T]§60.46(d)(4), [T](d)(6)-(7)

No

No

End

All of the following

requirements have been

taken from 40 CFR Part

60, Subpart D

SO2

40 CFR Part 60, Subpart Db(64 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 65: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Comply with the following:

Monitoring/Testing

§60.45(a), (c), (c)(1)-(2)

[G]§60.45(e), [G](f)

§60.45(g), (g)(2)(i)

Reporting

§60.45(g)

Yes

75

Does the

fossil fuel-fired steam

generator use a flue gas

desulfurization

device?

§60.45(b)(2)

No

Comply with the following:

Monitoring/Testing

§60.45(b)(2), (b)(4)

Comply with the following:

Monitoring/Testing

§60.45(c)(5)

Is the

affected facility

combusting fossil fuel

and nonfossil

fuel?

§60.45(c)(5)

Comply with the following:

Monitoring/Testing

§60.45(c)(3)-(4)

No

Yes

Is the

affected facility

combusting combinations

of fossil

fuels?§60.45(c)(4)

Comply with the following:

Monitoring/Testing

§60.45(c)(3)

Yes

60D.001

No

End

40 CFR Part 60, Subpart Db(65 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 66: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

Does

the facility

include a fuel gas

combustion

device?

76

§60.100(a)

Comply with the following:

Standard

§60.104(a)(1)

§60.104

Monitoring/Testing

§60.105(a), (e)

§60.106(a)

Reporting

§60.105(e)

§60.107(e), (f)

Is an

instrument for

continuous monitoring

and recording of H2S

concentration in

fuel gasses

used?

§60.105(a)(4)

77

78

SO2

All of the following

requirements have been

taken from 40 CFR Part

60, Subpart J.

EndYes

Yes

No

40 CFR Part 60, Subpart Db(66 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***

Page 67: TCEQ - 40 CFR Part 60, Subpart Db; Flowchart; December 20 ... · Subpart Da? §60.40b(e) No §60.40b(f) No Has there ... Below is a flowchart describing 40 CFR Part 60, Subpart Db

77 78

Comply with the following:

Monitoring/Testing

§60.105(a)(4), (4)(i), (4)(iii)

§60.105(e)(3)(ii)

[G]60.106(e)(1)

Recordkeeping

§60.105(a)(4)

Reporting

§60.105(e)(3)(ii)

Comply with the following:

Monitoring/Testing

§60.105(a)(3), (a)(3)(i)-(iii)

§60.105(e)(3)(i)

§60.106(e)(2)

Recordkeeping

§60.105(a)(3)

Reporting

§60.105(e)(3)(i)

Do the fuel

gas combustion devices

have a common source

of fuel gas?

Do the fuel

gas combustion devices

have a common source

of fuel gas?

Comply with the following:

Monitoring/Testing

§60.105(a)(4)(ii)

Comply with the following:

Monitoring/Testing

§60.105(a)(3)(iv)

Yes

§60.105(a)(4)(ii) §60.105(a)(3)(iv)

Yes

End

No No

40 CFR Part 60, Subpart Db(67 of 67)

12/20/2011 40 CFR Part 60, Subpart Db, Amended 01/28/09

The flowcharts are for use by sources subject to the Federal Operating Permit Program and are subject to change. ***