td-gabionwall-eng sheet00 (1) - viacon scheme for a guard-rail positioned on a gabion structure...

13
LEGEND 2 0.30 6 0.6 10 0.2 9 0.2 8 0.4 7 0.2 5 0.5 4 0.35 1 0.1 3 0.25 PEN THICKNESS PEN SETUP FOR PLOTTING SHEET 01 SHEET 02 SHEET 03 SHEET 05 SHEET 04 SHEET 06 GABION GREENING SHEET 08 DETAIL OF TYING GABION SHAPING SHEET 10 SHEET 11 GABION SHAPING DETAIL OF TYING GABION ASSEMBLY SHEET 09 SHEET 07 GABION WALLS TYPICAL SECTIONS FOR BRIDGE ABUTMENTS HEIGHTS OF 2-3-4m TYPICAL SECTION FOR SMALL BRIDGE ABUTMENT GABION WALLS ROCK SLOPE STABILIZATION WITH A LIGHT GABION STRUCTURE SLOPE STABILIZATION ON THE ROAD DOWNHILL SIDE VERTICAL WALLS - TYPICAL SECTIONS AND CONSTRUCTION DETAILS BATTERED WALLS - TYPICAL SECTIONS AND CONSTRUCTION DETAILS DRAINAGE AND CONSTRUCTION DETAILS GABIONS WITH DIAPHRAGMS GABIONS WITHOUT DIAPHRAGMS BOX GABIONS (VERTICAL MESH) DETAIL OF METALLIC RING GABIONS WITH DIAPHRAGMS OPENING AND FOLDING OPERATIONS BOX GABIONS (HORIZONTAL MESH) TYPICAL SCHEME FOR A GUARD-RAIL POSITIONED ON A GABION STRUCTURE GABION ANCHORAGE SYSTEM TO CONCRETE STRUCTURE END OR BEGINNING DETAIL OF A GABION WALL TYPICAL SECTION FOR SMALL BRIDGE ABUTMENT GABION WALLS RETAINING STRUCTURES WITH DRAINAGE CUT OFF WALLS FOR SLOPE STABILIZATION GABIONS WITHOUT DIAPHRAGMS DETAIL OF METALLIC RING OPENING AND FOLDING OPERATIONS 252 0.2 254 0.2 SHEET 12 GABION FILLING NOMINAL DIMENSIONS STANDARD DIMENSIONS TABLE TOLERANCE TABLE 128 0.2 SUBTITLE TYPE CHARACTER HEIGHT TITLE ARIAL 3.0 mm ARIAL 2.5 mm COMMENTS ARIAL 2.0 mm DIMENSION ARIAL 2.0 mm TEXT SETTING Date: Approved: Drawn: Designed: Date: Date: Issue / Revision: Rev: Drawn: App: Date: Officine Maccaferri S.p.A. assumes no responsability for drawings and calculations provided, as they must be intended as a general indication to suggest the proper use of its products. This drawing is stored in: MDL/Solutions/Environmental/Geotechnical Eng./Gravity Ret. Walls/TD-GabionWall-Eng.dwg e-mail: [email protected] - Website: www.maccaferri.com Tel. ++39 051 6436000 - Fax ++39 051 236507 - 40123 Bologna - Italia OFFICINE MACCAFERRI S.p.A. Via Agresti, 6 Drawing Title: Drawing No: Scale: Project No: Rev: GABION WALLS Sheet 00 1:100 00 02/04/04 02/04/04 R. Leprotti L. Giuliano TYPICAL DRAWING NOT FOR CONSTRUCTION

Upload: phungdiep

Post on 21-Apr-2018

241 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: TD-GabionWall-eng Sheet00 (1) - Viacon SCHEME FOR A GUARD-RAIL POSITIONED ON A GABION STRUCTURE GABION ANCHORAGE SYSTEM TO CONCRETE STRUCTURE END OR BEGINNING DETAIL OF A GABION WALL

LEG

EN

D

2 0.30

6 0.6

10 0.29 0.28 0.47 0.2

5 0.54 0.35

1 0.1

3 0.25

PE

N TH

ICK

NE

SS

PE

N S

ET

UP

FO

R P

LOT

TIN

G

SH

EE

T 01

SH

EE

T 02

SH

EE

T 03

SH

EE

T 05

SH

EE

T 04

SH

EE

T 06

GA

BIO

N G

RE

EN

ING

SH

EE

T 08

DE

TA

IL OF

TY

ING

GA

BIO

N S

HA

PIN

G

SH

EE

T 10

SH

EE

T 11

GA

BIO

N S

HA

PIN

G

DE

TA

IL OF

TY

ING

GA

BIO

N A

SS

EM

BLY

SH

EE

T 09

SH

EE

T 07

GA

BIO

N W

ALLS

TY

PIC

AL S

EC

TIO

NS

FO

R B

RID

GE

AB

UT

ME

NT

S H

EIG

HT

S O

F 2-3-4m

TY

PIC

AL S

EC

TIO

N F

OR

SM

ALL B

RID

GE

AB

UT

ME

NT

GA

BIO

N W

ALLS

RO

CK

SLO

PE

ST

AB

ILIZA

TIO

N W

ITH

A LIG

HT

GA

BIO

N S

TR

UC

TU

RE

SLO

PE

ST

AB

ILIZA

TIO

N O

N T

HE

RO

AD

DO

WN

HILL S

IDE

VE

RT

ICA

L WA

LLS - T

YP

ICA

L SE

CT

ION

S A

ND

CO

NS

TR

UC

TIO

N D

ET

AILS

BA

TT

ER

ED

WA

LLS - T

YP

ICA

L SE

CT

ION

S A

ND

CO

NS

TR

UC

TIO

N D

ET

AILS

DR

AIN

AG

E A

ND

CO

NS

TR

UC

TIO

N D

ET

AILS

GA

BIO

NS

WIT

H D

IAP

HR

AG

MS

GA

BIO

NS

WIT

HO

UT

DIA

PH

RA

GM

SB

OX

GA

BIO

NS

(VE

RT

ICA

L ME

SH

)

DE

TA

IL OF

ME

TA

LLIC R

ING

GA

BIO

NS

WIT

H D

IAP

HR

AG

MS

OP

EN

ING

AN

D F

OLD

ING

OP

ER

AT

ION

SB

OX

GA

BIO

NS

(HO

RIZ

ON

TA

L ME

SH

)

TY

PIC

AL S

CH

EM

E F

OR

A G

UA

RD

-RA

IL PO

SIT

ION

ED

ON

A G

AB

ION

ST

RU

CT

UR

E

GA

BIO

N A

NC

HO

RA

GE

SY

ST

EM

TO

CO

NC

RE

TE

ST

RU

CT

UR

EE

ND

OR

BE

GIN

NIN

G D

ET

AIL O

F A

GA

BIO

N W

ALL

TY

PIC

AL S

EC

TIO

N F

OR

SM

ALL B

RID

GE

AB

UT

ME

NT

GA

BIO

N W

ALLS

RE

TA

ININ

G S

TR

UC

TU

RE

S W

ITH

DR

AIN

AG

E C

UT

OF

F W

ALLS

FO

R S

LOP

E S

TA

BILIZ

AT

ION

GA

BIO

NS

WIT

HO

UT

DIA

PH

RA

GM

S

DE

TA

IL OF

ME

TA

LLIC R

ING

OP

EN

ING

AN

D F

OLD

ING

OP

ER

AT

ION

S

252 0.2254 0.2

SH

EE

T 12

GA

BIO

N F

ILLING

NO

MIN

AL D

IME

NS

ION

SS

TA

ND

AR

D D

IME

NS

ION

S T

AB

LET

OLE

RA

NC

E T

AB

LE

128 0.2

SU

BT

ITLE

TYP

EC

HA

RA

CT

ER

HE

IGH

T

TIT

LEA

RIA

L3.0 m

m

AR

IAL

2.5 mm

CO

MM

EN

TS

AR

IAL

2.0 mm

DIM

EN

SIO

NA

RIA

L2.0 m

m

TE

XT

SE

TT

ING

Date:

Approved:

Draw

n:

Designed:

Date:

Date:

Issue / Revision:

Rev:

Draw

n:A

pp:D

ate:

Officine M

accaferri S.p.A

. assumes no responsability for

drawings and calculations provided, as they m

ust be intended as a general indication to suggest the proper use of its products.

This drawing is stored in: MDL/Solutions/Environmental/Geotechnical Eng./Gravity Ret. Walls/TD-GabionWall-Eng.dwg

e-mail: com

es.officine@m

accaferri.com - W

ebsite: ww

w.m

accaferri.comT

el. ++39 051 6436000 - Fax ++39 051 236507

- 40123 Bologna - Italia

OFFIC

INE

MA

CC

AFE

RR

I S.p.A

.V

ia Agresti, 6

Draw

ing Title:

Draw

ing No:

Scale:

Project N

o:

Rev:

GA

BIO

N W

ALLS

Sheet 00

1:100

00

02/04/04

02/04/04

R. Leprotti

L. Giuliano

TY

PIC

AL D

RA

WIN

G

NO

T F

OR

CO

NS

TR

UC

TIO

N

Page 2: TD-GabionWall-eng Sheet00 (1) - Viacon SCHEME FOR A GUARD-RAIL POSITIONED ON A GABION STRUCTURE GABION ANCHORAGE SYSTEM TO CONCRETE STRUCTURE END OR BEGINNING DETAIL OF A GABION WALL

FILTER

FAB

RIC

WA

LL ST

EP

PE

D O

UT

SID

E

3

DIT

CH

DR

AIN

AG

ED

ET

AIL

DE

TA

IL

FILTER

FAB

RIC

DR

AIN

AG

ED

ET

AIL

DE

TA

ILD

ITC

H

3

5.0 mD

RA

INA

GE

CO

LLEC

TO

R A

T T

HE

TO

E3.0 m

DIT

CH

1.5%

3.0

EX

CA

VA

TIO

NP

RO

FILE

1.5%

MO

RT

AR

0.06

1.5%

GA

BIO

N W

ALLS

- TY

PIC

AL S

EC

TIO

NS

A

ND

DR

AIN

AG

E C

ON

ST

RU

CT

ION

DE

TA

ILS

AT

TH

E W

ALL'S

TO

PD

RA

INA

GE

CO

LLEC

TO

R

CO

NC

RE

TE

PR

EC

AS

T C

HA

NN

EL

WA

LL ST

EP

PE

D IN

SID

E

GA

BIO

N W

ALLS

- TY

PIC

AL S

EC

TIO

NS

AN

D C

ON

ST

RU

CT

ION

DE

TA

ILS

GA

BIO

N W

ALLS

- TY

PIC

AL S

EC

TIO

NS

AN

D C

ON

ST

RU

CT

ION

DE

TA

ILS

WA

LL ST

EP

PE

D IN

SID

E

VE

RT

ICA

L WA

LLS - T

YP

ICA

L SE

CT

ION

S

1-2

1-2

3

DIT

CH

DE

TA

IL

1.5%

BA

TT

ER

ED

WA

LLS - T

YP

ICA

L SE

CT

ION

S

WA

LL ST

EP

PE

D O

UT

SID

E

1-2

EX

CA

VA

TIO

NP

RO

FILE

FILT

ER

FA

BR

IC

3

1-2

MO

RT

AR

1.0 m

1.5%

CO

NC

RE

TE

CH

AN

NE

L

PIP

ED

RA

INA

GE

CO

LLEC

TO

R

GE

OT

EX

TILE

NO

N W

OV

EN

31-2

MA

TE

RIA

LF

RE

E D

RA

ININ

G

DR

AIN

AG

E

0.51.0

0.51.0

5.0 m

0.51.0

0.5

DR

AIN

AG

ED

ET

AIL

FILT

ER

FA

BR

IC

DE

TA

ILD

RA

INA

GE

Officine M

accaferri S.p.A

. assumes no responsability for

drawings and calculations provided, as they m

ust be intended as a general indication to suggest the proper use of its products.

Rev:

Issue / Revision:

Scale:

Draw

ing No:

Draw

ing Title:

App:

Draw

n:D

ate:

Project N

o:

Rev:

Draw

n:

Approved:

Designed:

Via A

gresti, 6O

FFICIN

E M

AC

CA

FER

RI S

.p.A.

Tel. ++39 051 6436000 - F

ax ++39 051 236507e-m

ail: comes.officine@

maccaferri.com

- Website: w

ww

.maccaferri.com

Date:

Date:

Date:

- 40123 Bologna - Italia

GA

BIO

N W

ALLS

Sheet 01

1:100

00L. G

iuliano

R. Leprotti

02/04/04

02/04/04

TY

PIC

AL D

RA

WIN

G

NO

T F

OR

CO

NS

TR

UC

TIO

N

Page 3: TD-GabionWall-eng Sheet00 (1) - Viacon SCHEME FOR A GUARD-RAIL POSITIONED ON A GABION STRUCTURE GABION ANCHORAGE SYSTEM TO CONCRETE STRUCTURE END OR BEGINNING DETAIL OF A GABION WALL

RE

TA

ININ

G S

TR

UC

TU

RE

S W

ITH

DR

AIN

AG

E C

UT

OF

F W

ALLS

RO

CK

SLO

PE

ST

AB

ILIZA

TIO

N W

ITH

A LIG

HT

GA

BIO

N S

TR

UC

TU

RE

1.0

3.0

3.0

FILTER

FAB

RIC

DR

AIN

AG

E

CO

LLEC

TIN

G P

IPE

BA

CK

FILL

TY

PIC

AL S

EC

TIO

N

GA

BIO

N W

ALL R

OC

K S

LOP

E

CU

T O

FF

WA

LL

FO

R S

LOP

E S

TA

BILIZ

AT

ION

1.5

2.0 3.0

CU

RR

EN

T S

EC

TIO

NG

AB

ION

WA

LL

3.0 - 5.0

6.01.0

3.0

3.0

1.0

6°2.0

3.5

SLO

PE

ST

AB

ILIZA

TIO

N O

N T

HE

RO

AD

DO

WN

HILL S

IDE

RE

TA

ININ

G S

TR

UC

TU

RE

ON

TH

E D

OW

NH

ILL SID

E O

FA

RO

AD

EM

BA

NK

ME

NT

1.0

4.5

2.5

AD

DIT

ION

AL W

ALL T

OS

TA

BILIZ

E T

HE

TO

E O

FT

HE

MA

IN S

TR

UC

TU

RE

4.0

7.0

1.0

1.5

CO

NC

RE

TE

SLA

B

6.0

1.0

BA

CK

FILL

CO

LLEC

TIN

G P

IPE

DR

AIN

AG

E

1.5G

AB

ION

WA

LL

Officine M

accaferri S.p.A

. assumes no responsability for

drawings and calculations provided, as they m

ust be intended as a general indication to suggest the proper use of its products.

Rev:

Issue / Revision:

Scale:

Draw

ing No:

Draw

ing Title:

App:

Draw

n:D

ate:

Project N

o:

Rev:

Draw

n:

Approved:

Designed:

Via A

gresti, 6O

FFICIN

E M

AC

CA

FER

RI S

.p.A.

Tel. ++39 051 6436000 - F

ax ++39 051 236507e-m

ail: comes.officine@

maccaferri.com

- Website: w

ww

.maccaferri.com

Date:

Date:

Date:

- 40123 Bologna - Italia

GA

BIO

N W

ALLS

Sheet 02

1:100

00L. G

iuliano

R. Leprotti

02/04/04

02/04/04

TY

PIC

AL D

RA

WIN

G

NO

T F

OR

CO

NS

TR

UC

TIO

N

This drawing is stored in: MDL/Solutions/Environmental/Geotechnical Eng./Gravity Ret. Walls/TD-GabionWall-Eng.dwg

Page 4: TD-GabionWall-eng Sheet00 (1) - Viacon SCHEME FOR A GUARD-RAIL POSITIONED ON A GABION STRUCTURE GABION ANCHORAGE SYSTEM TO CONCRETE STRUCTURE END OR BEGINNING DETAIL OF A GABION WALL

TY

PIC

AL S

EC

TIO

NS

FO

R B

RID

GE

AB

UT

ME

NT

S H

EIG

HT

S O

F 2-3-4m

.85

1.0.25

.5

TO

E P

RO

TE

CT

ION

WIT

H R

EN

O M

AT

TR

ES

SE

S

FILTER

FAB

RIC H

=2.0 m

1.0

.3

.25

2.0.25.25

.251.0

H=3.0 m

1.0

.3

.5

.5

1.0

TY

PIC

AL S

EC

TIO

N F

OR

SM

ALL B

RID

GE

AB

UT

ME

NT

GA

BIO

N W

ALLS

DO

UB

LE T

WIS

TE

DW

OV

EN

WIR

E G

AB

ION

SH

=4.0 m

B

C

1.0

1.0

1.0

2.0 m.25.25

.25

1.0.5

1.0.5

.5

.3

1.0

4.0

A

1.0

10.3

PLA

N V

IEWA

1.0

1.0.85

.51.5

4.0.5

4.0

B

.5.5

.25.25

2.01.0

Issue / Revision:

Officine M

accaferri S.p.A

. assumes no responsability for

drawings and calculations provided, as they m

ust be intended as a general indication to suggest the proper use of its products.

Rev:

Draw

ing Title:

Draw

ing No:

Scale:

App:

Draw

n:D

ate:

Project N

o:

Rev:

e-mail: com

es.officine@m

accaferri.com - W

ebsite: ww

w.m

accaferri.com

Draw

n:

Approved:

Designed:

Date:

Date:

Date:

- 40123 Bologna - Italia

Tel. ++39 051 6436000 - F

ax ++39 051 236507

OFFIC

INE

MA

CC

AFE

RR

I S.p.A

.V

ia Agresti, 6

GA

BIO

N W

ALLS

Sheet03

1:100

00L. G

iuliano

R. Leprotti

02/04/04

02/04/04

TY

PIC

AL D

RA

WIN

G

NO

T F

OR

CO

NS

TR

UC

TIO

N

This drawing is stored in: MDL/Solutions/Environmental/Geotechnical Eng./Gravity Ret. Walls/TD-GabionWall-Eng.dwg

Page 5: TD-GabionWall-eng Sheet00 (1) - Viacon SCHEME FOR A GUARD-RAIL POSITIONED ON A GABION STRUCTURE GABION ANCHORAGE SYSTEM TO CONCRETE STRUCTURE END OR BEGINNING DETAIL OF A GABION WALL

SE

CT

ION

B-B

SE

CT

ION

C-C

SE

CT

ION

A-A

.45.3

2.0

1.0

.3

.3

1.01.0 1.0

.51.5

4.0.2

4.0

.65

.85

1.15

.18

TY

PIC

AL S

EC

TIO

N F

OR

SM

ALL B

RID

GE

AB

UT

ME

NT

GA

BIO

N W

ALLS

DE

TA

IL

12.0

.25.25

.25.25

1.01.0

1.0

DE

TA

IL

5.0

3.4

.3

4.0 2.0

1.0

4.2.5

.3

ST

EE

L SU

PP

OR

TIN

G

BE

AM

1.01.0

1.0

DE

TA

IL OF

TH

E B

RID

GE

FLO

OR

ING

DE

TA

IL

.45

1.0.5

.5

1.0

.05

.25

1.2

.2

DE

TA

IL

.18

.2

.1 .45

.05.2

.07.18

C

Issue / Revision:

Officine M

accaferri S.p.A

. assumes no responsability for

drawings and calculations provided, as they m

ust be intended as a general indication to suggest the proper use of its products.

Rev:

Draw

ing Title:

Draw

ing No:

Scale:

App:

Draw

n:D

ate:

Project N

o:

Rev:

e-mail: com

es.officine@m

accaferri.com - W

ebsite: ww

w.m

accaferri.com

Draw

n:

Approved:

Designed:

Date:

Date:

Date:

- 40123 Bologna - Italia

Tel. ++39 051 6436000 - F

ax ++39 051 236507

OFFIC

INE

MA

CC

AFE

RR

I S.p.A

.V

ia Agresti, 6

GA

BIO

N W

ALLS

Sheet 04

1:100

00L. G

iuliano

R. Leprotti

02/04/04

02/04/04

TY

PIC

AL D

RA

WIN

G

NO

T F

OR

CO

NS

TR

UC

TIO

N

This drawing is stored in: MDL/Solutions/Environmental/Geotechnical Eng./Gravity Ret. Walls/TD-GabionWall-Eng.dwg

Page 6: TD-GabionWall-eng Sheet00 (1) - Viacon SCHEME FOR A GUARD-RAIL POSITIONED ON A GABION STRUCTURE GABION ANCHORAGE SYSTEM TO CONCRETE STRUCTURE END OR BEGINNING DETAIL OF A GABION WALL

GA

BIO

N G

RE

EN

ING

INT

ER

NA

L VE

GE

TA

TIV

E P

OC

KE

T

WILLO

W C

UTTIN

G

VE

GE

TA

TIV

E P

OC

KE

T

PLA

NT

OR

CU

TT

ING

RE

INF

OR

CE

D W

ITH

PLA

ST

IC M

ES

HT

YP

E "B

IOM

AC

C"

CO

CO

NU

T F

IBE

R G

EO

SY

NT

HE

TIC

,

VE

GE

TA

TIV

E S

OIL

0.80 approx

4.0

3.0

GA

BB

ION

GA

BB

ION

4.0

0.40-0.50

PO

SIT

ION

ED

ON

A G

AB

ION

ST

RU

CT

UR

E

FO

UN

DA

TIO

NC

ON

CR

ET

E

TY

PIC

AL S

CH

EM

E F

OR

A G

UA

RD

-RA

IL

Issue / Revision:

Officine M

accaferri S.p.A

. assumes no responsability for

drawings and calculations provided, as they m

ust be intended as a general indication to suggest the proper use of its products.

Rev:

Draw

ing Title:

Draw

ing No:

Scale:

App:

Draw

n:D

ate:

Project N

o:

Rev:

e-mail: com

es.officine@m

accaferri.com - W

ebsite: ww

w.m

accaferri.com

Draw

n:

Approved:

Designed:

Date:

Date:

Date:

- 40123 Bologna - Italia

Tel. ++39 051 6436000 - F

ax ++39 051 236507

OFFIC

INE

MA

CC

AFE

RR

I S.p.A

.V

ia Agresti, 6

GA

BIO

N W

ALLS

Sheet 05

1:100

00L. G

iuliano

R. Leprotti

02/04/04

02/04/04

TY

PIC

AL D

RA

WIN

G

NO

T F

OR

CO

NS

TR

UC

TIO

N

This drawing is stored in: MDL/Solutions/Environmental/Geotechnical Eng./Gravity Ret. Walls/TD-GabionWall-Eng.dwg

Page 7: TD-GabionWall-eng Sheet00 (1) - Viacon SCHEME FOR A GUARD-RAIL POSITIONED ON A GABION STRUCTURE GABION ANCHORAGE SYSTEM TO CONCRETE STRUCTURE END OR BEGINNING DETAIL OF A GABION WALL

ST

EE

L BA

RS

FO

R R

EIN

F. C

ON

CR

ET

E Ø

20mm

FIX

ED

BY

SY

NT

HE

TIC

RE

SIN

0.45 circa 0.45 circa

GA

BIO

N A

NC

HO

RA

GE

SY

ST

EM

TO

CO

NC

RE

TE

ST

RU

CT

UR

E

OF

AN

CH

OR

AG

EB

ET

WE

EN

GA

BIO

NA

ND

EX

IST

ING

CO

NC

RE

TE

ST

RU

CT

UR

E

DE

TA

IL

0.20

(min. length=gabion w

idth+0.50m

)

FO

R A

LL GA

BIO

N LE

NG

TH

ST

EE

L BA

R Ø

24

0.20

GA

BB

ION

E

EX

IST

ING

ST

RU

CT

UR

E

GA

BB

ION

S 2X

1X1m

EA

RT

H S

LOP

E

UP

ST

RE

AM

TH

E W

ALL

GA

BB

ION

S 1.5X

1X1m

FILLIN

G S

OIL P

RO

FILE

(1/4 CO

NE

)

DO

WN

ST

RE

AM

TH

E W

ALL

EA

RT

H LE

VE

L

GA

BB

ION

S 2X

1X1m

GA

BB

ION

S 2X

1X1m

UP

ST

RE

AM

TH

E W

ALL

EA

RT

H S

LOP

E

ST

EE

L BA

RS

FO

R R

EIN

F. C

ON

CR

ET

E Ø

12-14mm

OR

GA

LVA

NIZ

ED

ST

EE

L CA

BLE

Ø10-12m

m

EN

D O

R B

EG

INN

ING

DE

TA

IL OF

A G

AB

ION

WA

LL

GA

BB

ION

S 1.5X

1X1m

GA

BB

ION

S 1.5X

1X1m

GA

BIO

N E

ND

WIN

G W

ALL

ON

E E

AC

H 1m

EX

PA

NS

ION

BO

LTS

Issue / Revision:

Officine M

accaferri S.p.A

. assumes no responsability for

drawings and calculations provided, as they m

ust be intended as a general indication to suggest the proper use of its products.

Rev:

Draw

ing Title:

Draw

ing No:

Scale:

App:

Draw

n:D

ate:

Project N

o:

Rev:

e-mail: com

es.officine@m

accaferri.com - W

ebsite: ww

w.m

accaferri.com

Draw

n:

Approved:

Designed:

Date:

Date:

Date:

- 40123 Bologna - Italia

Tel. ++39 051 6436000 - F

ax ++39 051 236507

OFFIC

INE

MA

CC

AFE

RR

I S.p.A

.V

ia Agresti, 6

GA

BIO

N W

ALLS

Sheet 06

1:100

00L. G

iuliano

R. Leprotti

02/04/04

02/04/04

TY

PIC

AL D

RA

WIN

G

NO

T F

OR

CO

NS

TR

UC

TIO

N

This drawing is stored in: MDL/Solutions/Environmental/Geotechnical Eng./Gravity Ret. Walls/TD-GabionWall-Eng.dwg

Page 8: TD-GabionWall-eng Sheet00 (1) - Viacon SCHEME FOR A GUARD-RAIL POSITIONED ON A GABION STRUCTURE GABION ANCHORAGE SYSTEM TO CONCRETE STRUCTURE END OR BEGINNING DETAIL OF A GABION WALL

SID

E P

AN

EL

ST

RE

TC

H T

HE

UN

IT T

O F

OR

M T

HE

BO

X.

2) OP

EN

EA

CH

GA

BIO

N O

N A

FLA

T S

UR

FA

CE

3) FO

LDIN

G T

HE

FR

ON

T A

ND

BA

CK

SID

E.

OP

EN

ED

GA

BIO

N T

O F

OR

M T

HE

BO

X

OP

EN

ING

AN

D F

OLD

ING

OP

ER

AT

ION

S

HEIGHT

WID

TH

LENGTH

EV

EN

TU

AL W

OO

DE

N T

AB

LE

BO

X G

AB

ION

S (H

OR

IZO

NT

AL M

ES

H)

SE

LVE

DG

ING

BA

R

SE

LVE

DG

ING

WIR

E

SID

E P

AN

EL

SE

LVE

DG

ING

BA

R

OP

EN

ED

GA

BIO

N

LID

DIA

PH

RA

GM

S

GA

BIO

NS

WIT

H D

IAP

HR

AG

MS

SE

LVE

DG

ING

BA

R

SE

LVE

DG

ING

WIR

E

SE

LVE

DG

ING

WIR

E

LID

LIFT

ING

WIR

E

GA

BIO

NS

BU

ND

LE

1) OP

EN

TH

E B

UN

DLE

Issue / Revision:

Officine M

accaferri S.p.A

. assumes no responsability for

drawings and calculations provided, as they m

ust be intended as a general indication to suggest the proper use of its products.

Rev:

Draw

ing Title:

Draw

ing No:

Scale:

App:

Draw

n:D

ate:

Project N

o:

Rev:

e-mail: com

es.officine@m

accaferri.com - W

ebsite: ww

w.m

accaferri.com

Draw

n:

Approved:

Designed:

Date:

Date:

Date:

- 40123 Bologna - Italia

Tel. ++39 051 6436000 - F

ax ++39 051 236507

OFFIC

INE

MA

CC

AFE

RR

I S.p.A

.V

ia Agresti, 6

GA

BIO

N W

ALLS

Sheet 07

1:100

00L. G

iuliano

R. Leprotti

02/04/04

02/04/04

TY

PIC

AL D

RA

WIN

G

NO

T F

OR

CO

NS

TR

UC

TIO

N

This drawing is stored in: MDL/Solutions/Environmental/Geotechnical Eng./Gravity Ret. Walls/TD-GabionWall-Eng.dwg

Page 9: TD-GabionWall-eng Sheet00 (1) - Viacon SCHEME FOR A GUARD-RAIL POSITIONED ON A GABION STRUCTURE GABION ANCHORAGE SYSTEM TO CONCRETE STRUCTURE END OR BEGINNING DETAIL OF A GABION WALL

ME

TA

LLIC M

EC

HA

NIS

ED

RIN

GS

.T

HE

TY

ING

OP

ER

AT

ION

S C

AN

BE

FIN

ISH

ED

OR

BY

ME

TA

LLIC M

EC

HA

NIS

ED

RIN

GS

VE

RT

ICA

L PA

NE

L.

US

ING

TH

E B

IND

ING

WIR

E S

UP

PLIE

D W

ITH

TH

E G

AB

ION

S

5) FIX

TH

E V

ER

TIC

AL E

DG

ES

BY

ON

E O

R M

OR

E

PIC

K U

P T

HE

DIA

PH

RA

GM

S A

ND

TIE

IT T

O T

HE

OT

HE

R

GA

BIO

N S

HA

PIN

G

4) FO

LD U

P T

HE

LAT

ER

AL S

IDE

PA

NE

LS

FIX

TH

E V

ER

TIC

AL E

DG

ES

BY

TY

ING

AN

D O

TH

ER

VE

RT

ICA

L PA

NE

LS.

TH

IS W

ILL EN

SU

RE

TH

E G

OO

D LE

VE

LO

F THE

TOP

ED

GE

S O

F THE

BO

X.

TH

E T

OP

SE

LVE

DG

E B

AR

S E

AC

H O

TH

ER

GA

BIO

NS

WIT

H D

IAP

HR

AG

MS

AS

SE

MB

LING

OF

BO

X G

AB

ION

S

ME

TA

LLIC R

ING

SD

ETA

IL OF

DE

TA

IL OF

TY

ING

IF N

EC

ES

SA

RY

IS P

OS

SIB

LE T

O S

HA

PE

TH

E G

AB

ION

S F

OLD

ING

TH

E LA

TE

RA

L PA

NE

LS A

ND

LID

Issue / Revision:

Officine M

accaferri S.p.A

. assumes no responsability for

drawings and calculations provided, as they m

ust be intended as a general indication to suggest the proper use of its products.

Rev:

Draw

ing Title:

Draw

ing No:

Scale:

App:

Draw

n:D

ate:

Project N

o:

Rev:

e-mail: com

es.officine@m

accaferri.com - W

ebsite: ww

w.m

accaferri.com

Draw

n:

Approved:

Designed:

Date:

Date:

Date:

- 40123 Bologna - Italia

Tel. ++39 051 6436000 - F

ax ++39 051 236507

OFFIC

INE

MA

CC

AFE

RR

I S.p.A

.V

ia Agresti, 6

GA

BIO

N W

ALLS

Sheet 08

1:100

00L. G

iuliano

R. Leprotti

02/04/04

02/04/04

TY

PIC

AL D

RA

WIN

G

NO

T F

OR

CO

NS

TR

UC

TIO

N

This drawing is stored in: MDL/Solutions/Environmental/Geotechnical Eng./Gravity Ret. Walls/TD-GabionWall-Eng.dwg

Page 10: TD-GabionWall-eng Sheet00 (1) - Viacon SCHEME FOR A GUARD-RAIL POSITIONED ON A GABION STRUCTURE GABION ANCHORAGE SYSTEM TO CONCRETE STRUCTURE END OR BEGINNING DETAIL OF A GABION WALL

WID

TH

LENGTH

HEIGHT

SE

LVE

DG

ING

BA

R

SE

LVE

DG

ING

BA

R

SE

LVE

DG

ING

WIR

E

OP

EN

ED

GA

BIO

N T

O F

OR

M T

HE

BO

X

ST

RE

TC

H T

HE

UN

IT T

O F

OR

M T

HE

BO

X.

2) OP

EN

EA

CH

GA

BIO

N O

N A

FLA

T S

UR

FA

CE

3) FO

LDIN

G T

HE

FR

ON

T A

ND

BA

CK

SID

E.

SID

E P

AN

EL

EV

EN

TU

AL W

OO

DE

N T

AB

LE

LID

GA

BIO

N W

ITH

OU

T D

IAP

HR

AG

MS

SE

LVE

DG

ING

BA

RLID

SID

E P

AN

EL

SE

LVE

DG

ING

WIR

E

BO

X G

AB

ION

S (V

ER

TIC

AL M

ES

H)

OP

EN

ED

GA

BIO

N

LIFT

ING

WIR

E

SE

LVE

DG

ING

WIR

E

1) OP

EN

TH

E B

UN

DLE

GA

BIO

NS

BU

ND

LE

OP

EN

ING

AN

D F

OLD

ING

OP

ER

AT

ION

S

Issue / Revision:

Officine M

accaferri S.p.A

. assumes no responsability for

drawings and calculations provided, as they m

ust be intended as a general indication to suggest the proper use of its products.

Rev:

Draw

ing Title:

Draw

ing No:

Scale:

App:

Draw

n:D

ate:

Project N

o:

Rev:

e-mail: com

es.officine@m

accaferri.com - W

ebsite: ww

w.m

accaferri.com

Draw

n:

Approved:

Designed:

Date:

Date:

Date:

- 40123 Bologna - Italia

Tel. ++39 051 6436000 - F

ax ++39 051 236507

OFFIC

INE

MA

CC

AFE

RR

I S.p.A

.V

ia Agresti, 6

GA

BIO

N W

ALLS

Sheet 09

1:100

00L. G

iuliano

R. Leprotti

02/04/04

02/04/04

TY

PIC

AL D

RA

WIN

G

NO

T F

OR

CO

NS

TR

UC

TIO

N

This drawing is stored in: MDL/Solutions/Environmental/Geotechnical Eng./Gravity Ret. Walls/TD-GabionWall-Eng.dwg

Page 11: TD-GabionWall-eng Sheet00 (1) - Viacon SCHEME FOR A GUARD-RAIL POSITIONED ON A GABION STRUCTURE GABION ANCHORAGE SYSTEM TO CONCRETE STRUCTURE END OR BEGINNING DETAIL OF A GABION WALL

GA

BIO

N S

HA

PIN

G

IF N

EC

ES

SA

RY

IS P

OS

SIB

LE T

O S

HA

PE

TH

E G

AB

ION

S F

OLD

ING

TH

E LA

TE

RA

L PA

NE

LS A

ND

LID

DE

TAIL O

FM

ET

ALLIC

RIN

GS

DE

TA

IL OF

TY

ING

GA

BIO

N W

ITH

OU

T D

IAP

HR

AG

MS

4) FO

LD U

P T

HE

LAT

ER

AL S

IDE

PA

NE

LS

AS

SE

MB

LING

OF

BO

X G

AB

ION

S

TH

E T

OP

SE

LVE

DG

E B

AR

S E

AC

H O

TH

ER

TH

IS W

ILL EN

SU

RE

TH

E G

OO

D LE

VE

LO

F THE

TOP

ED

GE

S O

F THE

BO

X.

FIX

TH

E V

ER

TIC

AL E

DG

ES

BY

TY

ING

AN

D O

TH

ER

VE

RT

ICA

L PA

NE

LS.

5) FIX

TH

E V

ER

TIC

AL E

DG

ES

BY

ON

E O

R M

OR

E

US

ING

TH

E B

IND

ING

WIR

E S

UP

PLIE

D W

ITH

TH

E G

AB

ION

S

ME

TA

LLIC M

EC

HA

NIS

ED

RIN

GS

.T

HE

TY

ING

OP

ER

AT

ION

S C

AN

BE

FIN

ISH

ED

OR

BY

ME

TA

LLIC M

EC

HA

NIS

ED

RIN

GS

Issue / Revision:

Officine M

accaferri S.p.A

. assumes no responsability for

drawings and calculations provided, as they m

ust be intended as a general indication to suggest the proper use of its products.

Rev:

Draw

ing Title:

Draw

ing No:

Scale:

App:

Draw

n:D

ate:

Project N

o:

Rev:

e-mail: com

es.officine@m

accaferri.com - W

ebsite: ww

w.m

accaferri.com

Draw

n:

Approved:

Designed:

Date:

Date:

Date:

- 40123 Bologna - Italia

Tel. ++39 051 6436000 - F

ax ++39 051 236507

OFFIC

INE

MA

CC

AFE

RR

I S.p.A

.V

ia Agresti, 6

GA

BIO

N W

ALLS

Sheet 10

1:100

00L. G

iuliano

R. Leprotti

02/04/04

02/04/04

TY

PIC

AL D

RA

WIN

G

NO

T F

OR

CO

NS

TR

UC

TIO

N

This drawing is stored in: MDL/Solutions/Environmental/Geotechnical Eng./Gravity Ret. Walls/TD-GabionWall-Eng.dwg

Page 12: TD-GabionWall-eng Sheet00 (1) - Viacon SCHEME FOR A GUARD-RAIL POSITIONED ON A GABION STRUCTURE GABION ANCHORAGE SYSTEM TO CONCRETE STRUCTURE END OR BEGINNING DETAIL OF A GABION WALL

TH

E S

TO

NE

FILLIN

G A

ND

LID LA

CIN

G O

PE

RA

TIO

N.

FO

R E

AS

E O

F A

LIGN

ME

NT

A F

RA

ME

MA

Y B

E A

TT

AC

HE

DT

O T

HE

EM

PT

Y U

NIT

S A

ND

PU

LLED

TO

MA

KE

SU

RE

TH

AT

TH

E U

NIT

S A

RE

PR

OP

ER

LY S

TR

AIG

HT

EN

ED

.

ST

AN

DA

RD

DIM

EN

SIO

NS

TA

BLE

- GA

BIO

NS

DIA

PH

RA

GM

S

LEN

GT

H

TO

LER

AN

CE

ON

PR

OD

UC

TS

* = not less than nominal thickness

GA

BIO

N±5%

NO

MIN

AL D

IME

NS

ION

S

TY

PE

DO

UB

LE LO

OP

SIN

GLE

LOO

P

BIN

DIN

G IN

ST

RU

CT

ION

±5%±5%

HE

IGH

TT

HIC

KN

ES

SW

IDT

H

20 cm max.

0.500.500.50111

2 3 4 234

111111

L.H

.W

.

LxWxH

(m)

GALFAN (Zn-Al 5%-MM)

MODIFIED POLYETHILENE +

Ø 2.7m

m/3.7 m

m

23

8 x 10

1 3 2 1

WIR

E D

IAM

.M

ES

H T

YP

E

TO

LER

AN

CE

ON

WIR

E D

IAM

ET

ER

ME

SH

TY

PE

GA

BIO

N S

HA

LL BE

PLA

CE

D F

RO

NT

TO

FR

ON

TA

ND

BA

CK

TO

BA

CK

IN O

RD

ER

TO

EX

PE

DIT

E

OP

ER

AT

ION

.

TH

E B

AS

KE

T P

IEC

ES

SH

OU

LD B

E P

ULLE

DR

IGH

TLY

TO

GE

TH

ER

DU

RIN

G TH

E TY

ING

0.05±m

m

2.0Ø

mm

GA

BIO

NS

SH

ALL B

E C

ON

NE

CT

ED

TO

GE

TH

ER

AN

D A

LIGN

ED

BE

FO

RE

FILLIN

G T

HE

BA

SK

ET

S W

ITH

RO

CK

.A

LL CO

NN

EC

TIO

NS

(PA

NE

L-TO

-PA

NE

L AN

D B

AS

KE

T-T

O-B

AS

KE

T) S

HA

LL BE

ALR

EA

DY

CA

RR

IED

OU

T.

GA

BIO

N A

SS

EM

BLY

OP

TIO

NA

L8X

10

6X8

5X7

10X12

0.060.06

0.060.07

0.070.07

2.72.4

2.23.4

3.93.0

806050

+16%

-4%

TO

LER

AN

CE

TA

BLE

ME

SH

DIM

EN

SIO

NS

100

D (m

m)

TO

LER

AN

CE

Issue / Revision:

Officine M

accaferri S.p.A

. assumes no responsability for

drawings and calculations provided, as they m

ust be intended as a general indication to suggest the proper use of its products.

Rev:

Draw

ing Title:

Draw

ing No:

Scale:

App:

Draw

n:D

ate:

Project N

o:

Rev:

e-mail: com

es.officine@m

accaferri.com - W

ebsite: ww

w.m

accaferri.com

Draw

n:

Approved:

Designed:

Date:

Date:

Date:

- 40123 Bologna - Italia

Tel. ++39 051 6436000 - F

ax ++39 051 236507

OFFIC

INE

MA

CC

AFE

RR

I S.p.A

.V

ia Agresti, 6

GA

BIO

N W

ALLS

Sheet 11

1:100

00L. G

iuliano

R. Leprotti

02/04/04

02/04/04

TY

PIC

AL D

RA

WIN

G

NO

T F

OR

CO

NS

TR

UC

TIO

N

This drawing is stored in: MDL/Solutions/Environmental/Geotechnical Eng./Gravity Ret. Walls/TD-GabionWall-Eng.dwg

Page 13: TD-GabionWall-eng Sheet00 (1) - Viacon SCHEME FOR A GUARD-RAIL POSITIONED ON A GABION STRUCTURE GABION ANCHORAGE SYSTEM TO CONCRETE STRUCTURE END OR BEGINNING DETAIL OF A GABION WALL

HIG

H, A

S T

HE

CE

LL IS B

EIN

G1/3

CO

NN

EC

TIN

G.

WH

EN

MO

RE

TH

AN

ON

E

BE

OV

ER

FILLE

D A

PP

RO

XIM

AT

ELY

0.025 TO

0.04m T

O A

LLOW

FO

R N

AT

UR

AL S

ET

TLE

ME

NT

.T

HE

TO

P S

UR

FA

CE

SH

ALL B

ES

MO

OT

HLY

LEV

ELE

D, M

INIM

IZIN

GV

OID

S. E

NS

UR

E T

HA

T D

IAP

HR

AG

MT

OP

S A

RE

AC

CE

SS

IBLE

FO

R

VE

RT

ICA

L LAY

ER

OF

GA

BIO

NS

IS IN

ST

ALLE

D, U

NIT

S S

HA

LL

CR

OS

S T

IET

EN

SIO

NIN

G

AT

EN

D O

F S

TR

UC

TU

RE

CR

OS

S T

IEP

lan

1/51/5

GA

BIO

NN

EX

T

1/51/5

Front view

1.001.00

FILLE

D.

TH

EY

SH

ALL N

OT

DIS

INT

EG

RA

TE

ON

EX

PO

SU

RE

TO

WA

TE

R O

R W

EA

TH

ER

ING

DU

RIN

G T

HE

LIFE

OF

TH

E S

TR

UC

TU

RE

.

SU

FF

ICIE

NT

HA

ND

MA

NIP

ULA

TIO

N O

F T

HE

RO

CK

SH

ALL

BE

PE

RF

OR

ME

D T

O M

INIM

IZE

VO

IDS

AN

D A

CH

IEV

E A

MA

XIM

UM

DE

NS

ITY

OF

RO

CK

IN T

HE

GA

BIO

N. T

HE

RO

CK

IN E

XP

OS

ED

VE

RT

ICA

L FA

CE

S S

HA

LL BE

HA

ND

PLA

CE

DT

O R

ED

UC

E V

OID

S O

N T

HE

OU

TE

R F

AC

E.

ST

IFF

EN

ER

S O

R IN

TE

RN

AL

CR

OS

S T

IES

SH

ALL B

EIN

ST

ALLE

D A

S IN

DIC

AT

ED

,C

ON

NE

CTIN

G TH

E FR

ON

TA

ND

BA

CK

FA

CE

S O

F A

NY

SU

PP

OR

TE

D O

R E

XP

OS

ED

FA

CE

AT

TH

E V

ER

TIC

AL T

HIR

DP

OIN

TS FO

R A

GA

BIO

NS

1m

n 4 each 1 square meter

1.00

1/3

1/3C

RO

SS

TIE

RO

CK

TO

FILL G

AB

ION

S S

HA

LL BE

HA

RD

, AN

GU

LAR

TO

RO

UN

D, D

UR

AB

LE, A

ND

OF

SU

CH

QU

ALIT

Y T

HA

T

TH

E C

OM

ME

ND

ED

DIM

EN

SIO

NS

OF

RO

CK

TO

FILL G

AB

ION

S S

HA

LL BE

100-200mm

0.23m LIF

TS

FO

R 0.50m

HIG

H G

AB

ION

S.

LIFT

S F

OR

1m H

IGH

GA

BIO

NS

, AN

D

TH

E F

ILL LAY

ER

SH

ALL N

EV

ER

BE

MO

RE

TH

AN

0.30m H

IGH

ER

TH

AN

AN

Y A

DJO

ININ

G C

ELL.

RO

CK

SH

ALL B

E P

LAC

ED

IN 0.30m

GA

BIO

N F

ILLING

Issue / Revision:

Officine M

accaferri S.p.A

. assumes no responsability for

drawings and calculations provided, as they m

ust be intended as a general indication to suggest the proper use of its products.

Rev:

Draw

ing Title:

Draw

ing No:

Scale:

App:

Draw

n:D

ate:

Project N

o:

Rev:

e-mail: com

es.officine@m

accaferri.com - W

ebsite: ww

w.m

accaferri.com

Draw

n:

Approved:

Designed:

Date:

Date:

Date:

- 40123 Bologna - Italia

Tel. ++39 051 6436000 - F

ax ++39 051 236507

OFFIC

INE

MA

CC

AFE

RR

I S.p.A

.V

ia Agresti, 6

GA

BIO

N W

ALLS

Sheet 12

1:100

00L. G

iuliano

R. Leprotti

02/04/04

02/04/04

TY

PIC

AL D

RA

WIN

G

NO

T F

OR

CO

NS

TR

UC

TIO

N

This drawing is stored in: MDL/Solutions/Environmental/Geotechnical Eng./Gravity Ret. Walls/TD-GabionWall-Eng.dwg