technical datasheets for micro turbines bvg 2014 (en)
DESCRIPTION
Technical datasheets for micro turbines bvg 2014 (en)TRANSCRIPT
BVG Technical Datasheets for micro-turbines applications
OIL-INJECTED ROTARY SCREW GAS COMPRESSORS AND TREATMENT SYSTEMS FOR BIOGAS, LANDFILL GAS AND WET-GAS IN GENERAL Capacity up to 3000Nm3/h Available discharge pressures from 5.5bar(g) to 6.0bar(g) Nominal power from 4.0 to 355kW
By working in partnership with Adicomp to secure your future
Standard version is suitable for classified zones 1&2, indoor (OF) or outdoor installation with silenced and weather proof (WP) and safety features in accordance with ATEX standards.
BVG in accordance to ATEX95 or EN1127-1:2001 no-class. zones. (3.0kW-15kW)
2
www.adicomp.com
SPECIFICATION/MODEL U.M. BVG4.0-6.0AD INV
BVG5.5-6.0AD INV
BVG7.5-6.0AG INV
BVG9.0-6.0AG INV
BVG11- 6.0BD INV
BVG15-6.0CD INV
Suction pressure mbar 25 < 100 25 < 100 25 < 100 25 < 100 25 < 100 25 < 100
Suction temperature (min/max) °C 3/40 3/40 3/40 3/40 3/40 3/40
GAS humidity % 100 100 100 100 100 100
Free Gas Delivery (min/max) m3/h 0 < 22 < 32 0 < 22 < 48 0 < 32 < 66 0 < 35 < 80 0 < 48 < 92 0 < 48 < 132
Screw block rotation speed Rpm 1800 < 2570 1800 < 3560 2600 < 4900 3300 < 5900 1775 < 3320 1775 < 3200
Operating pressure bar(g) 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0
Discharge pressure (max) bar(g) 6.5 6.5 6.5 6.5 6.5 6.5
Ambient temperature °C -20/40 -20/40 -20/40 -20/40 -20/40 -20/40
Discharge gas temperature °C 45/50 45/50 45/50 45/50 45/50 45/50
Residual Oil in Gas mg/m3 3/4 3/4 3/4 3/4 3/4 3/4
Residual Oil in Gas (Fine Filtration Optional) mg/m3 0.1 0.1 0.1 0.1 0.1 0.1
Noise level ±3% (OF) dB(A) 80 80 82 82 82 82
Noise level ±3% (WP) & (S) dB(A) 70 70 72 72 74 74
Power absorbed kW 2.7 < 3.7 2.9 < 5.5 4.1 < 7.5 5.2 < 9.0 6.1 < 10.9 8.7 < 15.0
Power Supply (Voltage) V 400VAC 400VAC 400VAC 400VAC 400VAC 400VAC MAIN ELECTRIC MOTOR DATA Nominal power (Ex nA) zone 2 kW 5.5 7.5 11 11 15 18.5
Nominal power (Ex de) zone 1 kW 4.0 5.5 7.5 11 11 15
Efficiency class Cl. IE2 IE2 IE2 IE2 IE2 IE2
Nominal speed rpm 3000 3000 1500 1500 3000 3000
Voltage V 400 400 400 400 400 400
Nominal current (EX nA)/(Ex de) A 10.8/8.5 13.4/11.3 21/14.1 21/21.5 26.5/21.5 32/27
Frequency Hz 50 50 50 50 50 50
Efficiency (EX nA)/(Ex de) ƞ% 87.8/83.1 88.1/84.2 89.8/86 89.8/87.6 90.3/87.6 90.9/88.7
Degree of protection IP 55 55 55 55 55 55 MOTOR FAN SPECIFICATIONS Nominal Power kW 0.25 0.25 0.25 0.37 0.37 0.37
Nominal speed rpm 1500 3000 1500 1500 3000 3000
Voltage/Frequency V/Hz 400/50 400/50 400/50 400/50 400/50 400/50
Efficiency ƞ% 72.7 72.7 72.7 71.5 71.5 71.5
Degree of protection IP 55 55 55 55 55 55 DIMENSIONS
Dimensions cm 130 x 75 x 128
130 x 75 x 128
130 x 75 x 128
130 x 75 x 128
170 x 96 x 150
170 x 96 x 150
Connection In/Out RP/EN1092 1”1/4 - 3/4” 1”1/4 - 3/4” DN40 - 3/4” DN40 - 3/4” DN50 - 3/4” DN50 - 3/4”
Oxygen (O2) % 1.5 1.5 1.5 1.5 1.5 1.5
Siloxanes (SiO) mg/m3 5 5 5 5 5 5
Hydrogen sulphide (H2S) mg/m3 1000 1000 1000 1000 1000 1000
BVG - Oil injected rotary screw gas compressors
Electric motors (Ex nA) anti-spark type are de-rated of 20% for safety reasons when they work under inverter in ATEX zone 2. In case of BGR104 German standards, electric main motors installed are normally rated and no-ATEX version.
Standard version is suitable for classified zones 1&2, indoor (OF) or outdoor installation with silenced and weather proof (WP) and safety features in accordance with ATEX standards.
BVG in accordance to ATEX95 or EN1127-1:2001 no-class. zones. (18.5kW-75kW)
3
SPECIFICATION/MODEL U.M. BVG18.5-6.0CG INV
BVG22-6.0CG INV
BVG30-6.0HD INV
BVG37-6.0DD INV
BVG45-6.0DG INV
BVG55-6.0MG INV
BVG75-6.0MD INV
Suction pressure mbar 25 < 100 25 < 100 25 < 100 25 < 100 25 < 100 25 < 100 25 < 100
Suction temperature (min/max) °C 3/40 3/40 3/40 3/40 3/40 3/40 3/40
GAS humidity % 100 100 100 100 100 100 100
Free Gas Delivery (min/max) m3/h 0 < 82 < 166
0 < 93 < 197
0 < 177 < 241
0 < 186 < 330
0 < 200 < 403
0 < 255 < 526
0 < 387 < 709
Operating pressure bar(g) 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0
Discharge pressure (max) bar(g) 6.5 6.5 6.5 6.5 6.5 6.5 6.5
Ambient temperature °C -20/40 -20/40 -20/40 -20/40 -20/40 -20/40 -20/40
Discharge gas temperature °C 45/50 45/50 45/50 45/50 45/50 45/50 45/50
Residual Oil in Gas mg/m3 3/4 3/4 3/4 3/4 3/4 3/4 3/4
Residual Oil in Gas (Fine Filtration Optional) mg/m3 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Noise level ±3% (WP) & (S) dB(A) 74 74 74 76 76 76 76
Power Supply (Voltage) V 400VAC 400VAC 400VAC 400VAC 400VAC 400VAC 400VAC MAIN ELECTRIC MOTOR DATA Nominal power (Ex nA) zone 2 kW 22 30 37 45 55 75 90
Efficiency class Cl. IE2 IE2 IE2 IE2 IE2 IE2 IE2
Nominal speed rpm 1500 1500 3000 3000 1500 1500 3000
Voltage V 400 400 400 400 400 400 400
Nominal current (EX nA)/(Ex de) A 41.5/35.5 55/41.5 65/54 79/65 98/81 132/99 153/130
Frequency Hz 50 50 50 50 50 50 50
Efficiency (EX nA)/(Ex de) ƞ% 91.6/89.3 92.3/89.9 92.5/90.7 92.9/91.1 93.5/91.7 94/92.1 94.1/92.7
Degree of protection IP 55 55 55 55 55 55 55 MOTOR FAN SPECIFICATIONS
Nominal Power kW 0.37 0.37 0.75 0.75 0.75 2.2 2.2
Nominal speed rpm 1500 1500 3000 3000 1500 1500 1500
Voltage/Frequency V/Hz 400/50 400/50 400/50 400/50 400/50 400/50 400/50
Efficiency ƞ% 71.5 71.5 79.6 79.6 79.6 84.4 84.4
Degree of protection IP 55 55 55 55 55 55 55 DIMENSIONS
Dimensions cm 170 x 96 x 150
170 x 96 x 150
220 x 120 x 185
220 x 120 x 185
220 x 120 x 185
220 x 120 x 185
220 x 120 x 85
Connection In/Out RP/EN1092
DN80 - 1”1/4
DN80 -1”1/4
DN80 -DN40
DN100 -DN40
DN100 -DN40
DN100 -DN50
DN100 - DN50
Noise level ±3% (OF) dB(A) 84 84 86 86 88 88 90
Nominal power (Ex de) zone 1 kW 18.5 22 30 37 45 55 75
Power absorbed kW 10.0 < 18.5 11.5 < 22.0 14.0 < 27.5 24.4 < 37.0 23.4 < 45.0 28.6 < 55.0 44.7 < 75.0
Screw block rotation speed Rpm 2100 < 3980
2370 < 4750
1775 < 3600
1927 < 3065
1850 < 3725
1170 < 2360
1775 < 3125
Oxygen (O2) % 1.5 1.5 1.5 1.5 1.5 1.5 1.5
Siloxanes (SiO) mg/m3 5 5 5 5 5 5 5
Hydrogen sulphide (H2S) mg/m3 1000 1000 1000 1000 1000 1000 1000
Copyright © 2014 Adicomp s.r.l. - All rights reserved - Rev. August 2014
Electric motors (Ex nA) anti-spark type are de-rated of 20% for safety reasons when they work under inverter in ATEX zone 2. In case of BGR104 German standards, electric main motors installed are normally rated and no-ATEX version.
4
www.adicomp.com
Standard version is suitable for classified zones 1&2, indoor (OF) or outdoor installation with silenced and weather proof (WP) and safety features in accordance with ATEX standards.
BVG in accordance to ATEX95 or EN1127-1:2001 no-class. zones. (90kW-315kW)
SPECIFICATION/MODEL U.M. BVG90- 6.0EG INV
BVG110-6.0ED INV
BVG132-6.0EG INV
BVG160-6.0ND INV
BVG200-6.0ND INV
BVG250-6.0NG INV
BVG315-6.0NG INV
Suction pressure mbar 25 < 100 25 < 100 25 < 100 25 < 100 25 < 100 25 < 100 25 < 100
Suction temperature (min/max) °C 3/40 3/40 3/40 3/40 3/40 3/40 3/40
GAS humidity % 100 100 100 100 100 100 100
Free Gas Delivery (min/max) m3/h 0 < 404 < 841
0 < 647 < 1078
0 < 647 < 1204
0 < 662 < 1535
0 < 662 < 1885
0 < 1065 < 2350
0 < 1400 < 2850
Operating pressure bar(g) 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0 5.5 - 6.0
Discharge pressure (max) bar(g) 6.5 6.5 6.5 6.5 6.5 6.5 6.5
Ambient temperature °C -20/40 -20/40 -20/40 -20/40 -20/40 -20/40 -20/40
Discharge gas temperature °C 45/50 45/50 45/50 45/50 45/50 45/50 45/50
Residual Oil in Gas mg/m3 3/4 3/4 3/4 3/4 3/4 3/4 3/4
Residual Oil in Gas (Fine Filtration Optional) mg/m3 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Noise level ±3% (WP) & (S) dB(A) 78 78 78 78 80 80 80
Power Supply (Voltage) V 400VAC 400VAC 400VAC 400VAC 400VAC 400VAC 400VAC MAIN ELECTRIC MOTOR DATA Nominal power (Ex nA) zone 2 kW 110 132 160 200 250 315 355
Efficiency class Cl. IE2 IE2 IE2 IE2 IE2 IE2 IE2
Nominal speed rpm 1500 3000 1500 1500 1500 3000 3000
Voltage V 400 400 400 400 400 400 400
Nominal current (EX nA)/(Ex de) A 195/161 220/200 275/237 345/282 430/356 523/421 589/523
Frequency Hz 50 50 50 50 50 50 50
Efficiency (EX nA)/(Ex de) ƞ% 94.5/94 94.8/94.5 94.9/94.6 95.1/95.3 95.1/95.3 96.6/96.2 96.7/96.6
Degree of protection IP 55 55 55 55 55 55 55 MOTOR FAN SPECIFICATIONS
Nominal Power kW 2.2 2x 2.2 2x 2.2 2x 2.2 4x 3.0 4x 3.0 4x 3.0
Nominal speed rpm 1500 1500 1500 1500 1500 1500 1500
Voltage/Frequency V/Hz 400/50 400/50 400/50 400/50 400/50 400/50 400/50
Efficiency ƞ% 84.4 84.4 84.4 84.4 85.5 85.5 85.5
Degree of protection IP 55 55 55 55 55 55 55 DIMENSIONS
Dimensions cm 300 x 150 x 210
300 x 150 x 210
300 x 150 x 210
360 x 200 x 224
360 x 200 x 224
410 x 210 x 224
410 x 210 x 224
Connection In/Out RP/EN1092
DN150 - DN50
DN200 - DN80
DN200 - DN80
DN200 - DN80
DN250 - DN100
DN250 - DN100
DN300 - DN100
Noise level ±3% (OF) dB(A) 90 90 92 92 92 94 94
Nominal power (Ex de) zone 1 kW 90 110 132 160 200 250 315
Power absorbed kW 47.0 < 90.0 69.0 < 110.0
75.0 < 132.0
75.0 < 160.0
75.0 < 200.0
115.0 < 250.0
162.0 < 315.0
Screw block rotation speed Rpm 1160 < 2330
1800 < 2960
1800 < 3350 870 < 1943 870 < 2390 1390 <
2980 1775 < 3623
Oxygen (O2) % 1.5 1.5 1.5 1.5 1.5 1.5 1.5
Siloxanes (SiO) mg/m3 5 5 5 5 5 5 5
Hydrogen sulphide (H2S) mg/m3 1000 1000 1000 1000 1000 1000 1000
BVG - Oil injected rotary screw gas compressors
Electric motors (Ex nA) anti-spark type are de-rated of 20% for safety reasons when they work under inverter in ATEX zone 2. In case of BGR104 German standards, electric main motors installed are normally rated and no-ATEX version.
5
Copyright © 2014 Adicomp s.r.l. - All rights reserved - Rev. August 2014
———————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————
Download a QR Reader and scan the code to read this catalog on your tablet.
Adicomp s.r.l. via del Progresso, 35 - 36050 Sovizzo (Vicenza) Italy Ph. +39 0444 573979 - Fax +39 0444 809186 [email protected] - www.adicomp.com
Copyright © 2014 Adicomp s.r.l. – All rights reserved Datas are indicative and may be changed in any time without notice. Rev. August 2014