Technical Support Document, Permit Action Number: 15700015 012 Page 1 of 9 TECHNICAL SUPPORT DOCUMENT For DRAFT AIR EMISSION PERMIT NO. 15700015012 This technical support document (TSD) is intended for all parties interested in the draft permit and to meet the requirements that have been set forth by the federal and state regulations (40 CFR § 70.7(a)(5) and Minn. R. 7007.0850, subp. 1). The purpose of this document is to provide the legal and factual justification for each applicable requirement or policy decision considered in the preliminary determination to issue the draft permit. 1. General Information 1.1 Applicant and Stationary Source Location: Table 1. Applicant and Source Address Applicant/Address Stationary Source/Address (SIC Code: 3321, 3365) FederalMogul Corporation 520 North 8th Street Lake City, MN 55041 FederalMogul Corp Powertrain Systems 520 North 8th Street Lake City, Wabasha County, Minnesota 55041 Contact: Ron Koller 6513458005 1.2 Facility Description FederalMogul Corporation Powertrain Systems (FederalMogul) owns and operates a foundry in Lake City, Minnesota. The facility consists of separate gray iron and aluminum foundry operations, supporting machine operations, and natural gasfired boilers. The raw materials consist entirely of refined and scrap metals, and scrap generated from inhouse machining operations and various materials for mold making. The gray iron foundry is dedicated to making sleeves, rather than pistons. FederalMogul operates the gray iron foundry with six induction furnaces with a combined rated capacity of 21.41 tons of metal melted per hour. Other equipment at the facility includes a seventon holding furnace for storing molten gray iron, a high pressure pouring and cooling line rated at 125 molds per hour, sand muller, sand silos and three centrifugal casting lines. In addition, for the aluminum foundry, the facility operates the central melting furnace, holding furnaces, and casting and heat treating ovens. The main sources of air emissions are Particulate Matter (PM), PM less than 10 microns (PM 10 ) and Nitrogen Oxides (NO X ). The facility operates under an individual State permit and is an area source under National Emission Standards for Hazardous Air Pollutants (40 CFR pt. 63). 1.3 Description of the Activities Allowed by this Permit Action This permit action is for two Major Amendments and an Administrative Amendment. One major amendment (DQ 4517) will add an emergency generator (EU192) to the facility with its own associated stack (SV053). The engine will run on diesel fuel, not have control equipment and be used for emergency use only.

Upload: others

Post on 15-Feb-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  •  

    Technical Support Document, Permit Action Number: 15700015 ‐ 012 Page 1 of 9   

     TECHNICAL SUPPORT DOCUMENT 

    For DRAFT AIR EMISSION PERMIT NO. 15700015‐012 

     This technical support document (TSD) is intended for all parties interested in the draft permit and to meet the requirements that have been set forth by the federal and state regulations (40 CFR § 70.7(a)(5) and Minn. R. 7007.0850, subp. 1). The purpose of this document is to provide the legal and factual justification for each applicable requirement or policy decision considered in the preliminary determination to issue the draft permit.  1. General Information  1.1 Applicant and Stationary Source Location: 

     Table 1. Applicant and Source Address 

    Applicant/Address  Stationary Source/Address (SIC Code: 3321, 3365) Federal‐Mogul Corporation 520 North 8th Street Lake City, MN 55041 

    Federal‐Mogul Corp Powertrain Systems 520 North 8th Street Lake City, Wabasha County, Minnesota 55041 

    Contact: Ron Koller 651‐345‐8005   1.2 Facility Description Federal‐Mogul Corporation Powertrain Systems (Federal‐Mogul) owns and operates a foundry in Lake City, Minnesota. The facility consists of separate gray iron and aluminum foundry operations, supporting machine operations, and natural gas‐fired boilers. The raw materials consist entirely of refined and scrap metals, and scrap generated from in‐house machining operations and various materials for mold making. The gray iron foundry is dedicated to making sleeves, rather than pistons. 

    Federal‐Mogul operates the gray iron foundry with six induction furnaces with a combined rated capacity of 21.41 tons of metal melted per hour. Other equipment at the facility includes a seven‐ton holding furnace for storing molten gray iron, a high pressure pouring and cooling line rated at 125 molds per hour, sand muller, sand silos and three centrifugal casting lines. In addition, for the aluminum foundry, the facility operates the central melting furnace, holding furnaces, and casting and heat treating ovens. 

    The main sources of air emissions are Particulate Matter (PM), PM less than 10 microns (PM10) and Nitrogen Oxides (NOX). The facility operates under an individual State permit and is an area source under National Emission Standards for Hazardous Air Pollutants (40 CFR pt. 63). 

     1.3 Description of the Activities Allowed by this Permit Action This permit action is for two Major Amendments and an Administrative Amendment. One major amendment (DQ 4517) will add an emergency generator (EU192) to the facility with its own associated stack (SV053). The engine will run on diesel fuel, not have control equipment and be used for emergency use only. 

  •  

    Technical Support Document, Permit Action Number: 15700015 ‐ 012 Page 2 of 9   

    The second major amendment (DQ 4622) will re‐route emissions from machining lathes (EU052‐055, 079‐081) to the baghouse CE016 (SV039). These lathes were previously controlled by baghouse CE015 (SV030). No permit limits will be revised by this change and thus, no previously modeled parameters will be affected. In addition, EU050 and EU051 (Casting Cutting Stations 1‐4 and 1‐5) and EU077 and EU078 (Casting Cutting Station 2‐4 and 2‐5) will be removed. 

    The administrative amendment is for a 120‐day extension on the SV041 performance test for PM2.5. The extension moved the due date to on or before November 13, 2010. The test was conducted November 9‐11, 2010. The most recent test for PM, PM10, PM2.5 and opacity at SV041 was conducted February 24, 2011. 

    Additional changes to the permit include removing requirements for tasks that have been completed, and updating Title I conditions to reflect the fact the facility operates under a State individual permit. Since the facility is no longer a Pt. 70 permit, all citations referencing CAM no longer are applicable. As CAM no longer applies, GP010 will be removed from the permit and associated items from GP010 will be moved to GP002 (fabric filters, non‐CAM). Collection and capture efficiencies at GP002 will be combined into overall control efficiency limits. The requirements at GP004 were combined into GP002 and GP004 was removed. The previous permit contained a schedule of compliance (Table C) to certify hoods at the facility. This schedule ran from 2009 to 2011, so these requirements can also be removed. The general provisions from 40 CFR pt. 63, subp. A that are applicable to 40 CFR pt. 63, subp. ZZZZZ have been added to GP013. The general provisions applicable to 40 CFR pt. 63, subp. ZZZZZZ have been added to GP014. 

     1.4 Facility Emissions: 

    Table 2. Emissions Summary (minor NSR source scenario) 

    Pollutant 

    Unlimited Potential Emissions from the 

    Modification (tpy) 

    Limited Potential Emissions from the Modification 

    (tpy) 

    Total Facility Limited Potential Emissions** 

    (tpy) 

    Pt. 70 Threshold for Criteria Pollutants 

     (tpy) PM  0.67  0.67 88.19 100PM10  0.67  0.67 57.75 100PM2.5  0.67  0.67 24.53 100NOX  14.33  14.33 94.88 100SO2  4.70  4.70 5.26 100CO  3.07  3.07 14.76 100Ozone (VOC)  14.33  14.33 47.48 100Lead  ‐‐  ‐‐ 0.63 10CO2e*  2691.49  2691.49 66,849 100,000HAP Total  ‐‐  ‐‐ 0.26 25*Carbon dioxide equivalents as defined in Minn. R. 7007.0100. ** Including Insignificant Activities  

    Table 3. Facility Classification Classification  Major/Affected Source Synthetic Minor/Area Minor/Area

    PSD   X (PM/PM10/PM2.5)  Part 70 Permit Program  X (PM10/PM2.5)  Part 63 NESHAP  X  

  •  

    Technical Support Document, Permit Action Number: 15700015 ‐ 012 Page 3 of 9   

    2. Regulatory and/or Statutory Basis  New Source Review Federal‐Mogul is one of 28 source categories listed in the Prevention of Significant Deterioration (PSD) rules that are classified as major sources, if the potential‐to‐emit (PTE) is equal to or greater than 100 tons per year (tpy) of any single regulated pollutant. Title I Condition limits were established in 2000 before the facility became a major source. PTE was revised during permit action ‐011 resulting in all regulated pollutants being below 100 tpy; therefore the facility is a non‐major source under New Source Review (40 CFR § 52.21). This permit action does not change the facility status under NSR.  Part 70 Permit Program The limited PTE of all Pt. 70 regulated pollutants are below the 100 tpy threshold; therefore the facility is a non‐major source under the Pt. 70 program. Existing limits in the permit to avoid major source and modification under 40 CFR § 52.21 were updated to also avoid classification as major source under 40 CFR § 70.2.  New Source Performance Standards (NSPS) The proposed emergency engine (EU192) is subject to New Source Performance Standard subp. IIII: Stationary Compression Ignition (CI) Internal Combustion Engines (ICE).  National Emission Standards for Hazardous Air Pollutants (NESHAP) The proposed emergency engine (EU192) is subject to NESHAP subp. ZZZZ: Stationary Reciprocating Internal Combustion Engines (RICE).  Compliance Assurance Monitoring (CAM) This is an individual State permit so CAM does not apply to the facility. All CAM citations effective from permit no. 15700015‐010 that were no longer applicable as of the issuance date of permit no. 15700015‐011 were removed from the permit in this permit action (‐012).  Environmental Review & Air Emissions Risk Analysis (AERA) An Environmental Assessment Worksheet (EAW) is not required for this permit action, and the Permittee is not required to perform an AERA.  Minnesota State Rules Portions of the facility are subject to the following Minnesota Standards of Performance: 

    Minn. R. 7011.2300 Standards of Performance for Stationary Internal Combustion Engines (ICE)  

    Table 4. Regulatory Overview of Units Affected by the Modification/Permit Amendment Subject Item*  Applicable Regulations  Rationale 

    EU192  40 CFR pt. 60, subp. IIII 40 CFR pt. 63, subp. ZZZZ  Minn. R. 7011.2300, subps. 1, 2 

    New Source Performance Standard for Stationary CI ICE. National Emission Standards for Hazardous Air Pollutants for Stationary RICE. State Standards for Stationary ICE. 

  •  

    Technical Support Document, Permit Action Number: 15700015 ‐ 012 Page 4 of 9   

    Subject Item*  Applicable Regulations  Rationale 

    GP002  Title I Conditions to avoid NSR and Pt. 70 and demonstrate compliance with NAAQS 

    Requirements to vent emissions to air pollution control equipment to remain a minor source and modification under NSR and minor source under Pt. 70. 

    Standards of Performance for Industrial Process Equipment: applies to individual emission units. 

    *Location of the requirement in the permit (e.g., EU, SV, GP, etc.).  3. Technical Information Federal‐Mogul will install an emergency generator (EU192) with its own stack (SV053) and no associated control equipment. The engine will run on diesel fuel and be used for emergency purposes only. The engine will be subject to New Source Performance Standards (NSPS) for Stationary Compression Ignition (CI) Internal Combustion Engines (ICE), State Performance Standards for Stationary ICE and National Emission Standards for Hazardous Air Pollutants (NESHAP) for Stationary Reciprocating Internal Combustion Engines (RICE). The emergency engine will comply with the applicable NESHAP standard by demonstrating compliance with the applicable NSPS requirements. The engine’s rated capacity is 530 hp and is model year 2013 which qualifies it as a Tier 3 engine per Table 1 of 40 CFR Section 89.112(a). 

    The administrative amendment application included with this permit action was for a 120‐day extension on the performance test for PM2.5 on SV041 (CE018). The extension moved the test due date from July 16, to November 13, 2010. The most recent performance test for SV041 was conducted February 24, 2011. Other performance test dates, frequencies and future test dates for SV030, SV039, SV041 and SV045 are shown below in Table 5. Performance test dates in the permit have been updated to the frequencies and due dates shown below. Test frequency plan requirements for initial PM2.5 tests were removed. The performance tests below included verification of PM2.5 emission rates. With this permit action, PM2.5 limits will be added to the permit at the SV levels listed in Table 6 giving a 10 % buffer above the verified results from the PM2.5 tests. 

    Table 5. Future Performance Testing Stack  Previous 

    Test Test Frequency Pollutants Tested Next Test 

    Due SV030  9/29/11  every 60 months PM, PM10, PM2.5, opacity 9/29/16 SV039  11/15/12  every 60 months PM, PM10, PM2.5, opacity 11/15/17 SV041  2/24/11  every 60 months PM, PM10, PM2.5, opacity 2/24/16 SV045  8/1/12  every 60 months PM, PM10, PM2.5, opacity 8/1/17 

     A notification of compliance for NESHAP subp. ZZZZZZ was received July 9, 2009. The applicable requirements for this NESHAP were placed in the permit during the last amendment (‐011). The compliance trigger date (June 27, 2011) requirement will be removed during this permit action. 

    Federal‐Mogul is also re‐routing seven machining lathes (EU052‐055, 079‐081) from CE015 (SV030) to CE016 (SV039). Permit limits at SV030 and SV039 will not be affected by this change and there are no changes to any previously modeled parameters in permit Appendix D. 

    Cleanup and Corrections to the Permit 

  •  

    Technical Support Document, Permit Action Number: 15700015 ‐ 012 Page 5 of 9   

    Requirements and citations at the Total Facility level of the permit were updated to current MPCA practice. Federal‐Mogul’s permit type went from Federal Pt. 70/Major for NSR in permit action ‐010 to an individual State in permit action ‐011. Title I conditions in the permit to avoid major source status and modification under 40 CFR Section 52.21 and Minn. R. 7007.3000 are being updated to include limits to avoid major source status under 40 CFR Section 70.2 and Minn. R. 7007.0200 in the citations. None of the permit limits are being changed. Also Title I conditions to avoid only a major modification under 40 CFR Section 52.21 and Minn. R. 7007.3000 will now avoid major status under 40 CFR Sections 52.21 and 70.2. None of these permit limits are being changed either.  

    Federal‐Mogul first became a major source under 40 CFR Sections 52.21 and 70.2 and initially took limits to avoid a major modification under the federal Prevention of Significant Deterioration (PSD) program and thus, avoid the need to conduct a Best Available Control Technology (BACT) analysis with that permit action. (See discussion in permit 15700015‐002 TSD) The facility production limit established in PER002 of 121,680 tpy was reduced to 65,000 tpy in PER008 in order to show compliance with National Ambient Air Quality Standards for PM10.  

    Also, as part of becoming a State permit and no longer being a major source under 40 CFR Section 70.2 the Compliance Assurance Monitoring (CAM) requirements from 40 CFR pt. 64 are no longer applicable. All citations referencing CAM (i.e., 40 CFR pt. 64) were removed from the permit. Since CAM no longer applies to this facility, GP010 will be removed from the permit and associated items under GP010 will be moved to GP002 (non‐CAM fabric filters). The previous permit contained capture and collection efficiencies for fabric filters in GP002 and 010. This permit will combine the two efficiencies into an overall control efficiency for each fabric filter by multiplying the capture and collection efficiencies. (i.e., control efficiency = capture efficiency * collection efficiency) The resultant control efficiencies for GP002 are shown below in Table 6. 

    The permit contained a schedule of compliance in Table C to certify the hoods at the facility. This hood certification was to run for three years from 2009 to 2011. Since this has been completed, the associated permit requirements are being removed. 

    3.1 Calculations of Potential to Emit and Emissions Increase Analysis Potential‐to‐emit (PTE) calculations for the emergency generator are included in Attachment 2 to this TSD. PTE for greenhouse gases (GHG) were provided with the application for permit ‐011 and included again with the application for permit ‐012. As GHGs were not regulated pollutants at the time of permit ‐011 issuance the PTE data was not entered in the facility description at that time. All PTE for GHG (including CO2, CH4, N2O and CO2e) will be entered into the facility description with permit ‐012 and reflect the global warming potentials as revised in the November 29, 2013 Federal Register.  3.2 Dispersion Modeling Federal‐Mogul’s permit contains the following language triggering the need for modeling. 

    For changes that require a minor, moderate, or major permit amendment and affect any modeled parameter or emission rate documented in Appendix D, a Remodeling Submittal requirement is triggered. 

    Federal‐Mogul was in contact with MPCA staff via email correspondence and phone conversations and determined that modeling would not be required for the following reasons: 

    The proposed generator does not affect the original modeled parameters or emission rates. 

  •  

    Technical Support Document, Permit Action Number: 15700015 ‐ 012 Page 6 of 9   

    Emergency generators, per MPCA modeling guidelines, do not normally require modeling. EU192 will operate under Best Management Practices (BMPs) for emergency generators. 

     3.3 Monitoring In accordance with the Clean Air Act, it is the responsibility of the owner or operator of a facility to have sufficient knowledge of the facility to certify that the facility is in compliance with all applicable requirements.  In evaluating the monitoring included in the permit, the MPCA considered the following: 

    the likelihood of the facility violating the applicable requirements;  whether add‐on controls are necessary to meet the emission limits;  the variability of emissions over time;  the type of monitoring, process, maintenance, or control equipment data already available for 

    the emission unit;  the technical and economic feasibility of possible periodic monitoring methods; and  the kind of monitoring found on similar units elsewhere. 

     The table below summarizes the monitoring requirements associated with this amendment.  

    Table 6. Monitoring Subject Item* 

    Requirement (rule basis)  Monitoring  Discussion 

    EU192  CO: 

  •  

    Technical Support Document, Permit Action Number: 15700015 ‐ 012 Page 7 of 9   

    Subject Item* 

    Requirement (rule basis)  Monitoring  Discussion 

    SV039 (CE016) 

    PM10: ≤ 1.25 lb/hr on 24‐hr rolling avg  PM2.5:  79.2% control efficiency PM2.5: > 77.6% control efficiency (to avoid 40 CFR §§ 52.21 and 70.2; Minn. R. 7007.3000 and 7007.0200) 

    Recordkeeping: daily visible emission check, reading, monitoring and maintain pressure drop 

    Monitoring based on MN Performance Standard for Control Equipment is adequate to have a reasonable assurance of compliance (daily, periodic inspections and corrective actions). All situations warranting corrective actions are deviations. The Permittee shall report the deviations in the semiannual deviations report. 

    *Location of the requirement in the permit (e.g., EU, SV, GP, etc.).  3.4 Insignificant Activities Federal‐Mogul Corp Powertrain Systems has several operations which are classified as insignificant activities under the MPCA’s permitting rules. These are listed in Appendix B to the permit. Space heaters that previously qualified as insignificant activities under Minn. R. 7007.1300, subp. 3.A will now qualify under Minn. R. 7007.1300, subp. 3.I.  

  •  

    Technical Support Document, Permit Action Number: 15700015 ‐ 012 Page 8 of 9   

    The permit is required to include periodic monitoring for all emissions units, including insignificant activities, per EPA guidance. The insignificant activities at this Facility are only subject to general applicable requirements. Using the criteria outlined earlier in this TSD, the following table documents the justification why no additional periodic monitoring is necessary for the insignificant activities affected by this modification.   

    Table 7. Insignificant Activities 

    Insignificant Activity General Applicable 

    Emission limit  Discussion Space heaters fueled by natural gas or propane, now qualifying under Minn. R. 7007.1300, subp. 3.I. 

    PM ≤ 0.4 lb/MMBtuOpacity ≤ 20% with exceptions (Minn. R. 7011.0515) 

    For these space heaters, based on the fuels used and EPA published emissions factors, it is highly unlikely that it could violate the applicable requirement. In addition, these types of units are typically operated and vented inside a building, so testing for PM or opacity is not feasible. 

     3.5 Permit Organization  In general, the permit meets the MPCA Delta Guidance for ordering and grouping of requirements. One area where this permit deviates slightly from Delta guidance is in the use of appendices. While appendices are fully enforceable parts of the permit, in general, any requirement that the MPCA thinks should be electronically tracked (e.g., limits, submittals, etc.), should be in Table A or B of the permit. The main reason is that the appendices are word processing sections and are not part of the electronic tracking system. Violation of the appendices can be enforced, but the computer system will not automatically generate the necessary enforcement notices or documents. Staff must generate these.  

    Another area that deviates from the guidance is in the use of groups where the requirements in the group apply to the members of the group individually. This was done in order to shorten the permit and where no testing or tracking specific to a unit is in the permit (thereby reducing the likelihood that there where will be further unit‐specific requirements later).  3.6 Comments Received to be completed after public notice and EPA review  Public Notice Period:  ‐  EPA 30‐day Review Period:  ‐   Comments were  received from the public during the public notice period.    Comments were  received from EPA during their review period. Changes to the permit were  made as a result of the comments. Provide summary of changes. >  4. Permit Fee Assessment  

  •  

    Technical Support Document, Permit Action Number: 15700015 ‐ 012 Page 9 of 9   

    Attachment 3 to this TSD contains the MPCA’s assessment of Application and Additional Points used to determine the permit application fee for this permit action as required by Minn. R. 7002.0019. The permit action includes three permit applications, of which all were received after the effective date of the rule (July 1, 2009). Additional points include reviews of applicable NSPS subp. IIII (10 pts.) and NESHAP subp. ZZZZ (10 pts.).  5. Conclusion  Based on the information provided by Federal‐Mogul Corp Powertrain Systems, the MPCA has reasonable assurance that the proposed operation of the emission facility, as described in the Air Emission Permit No. 15700015‐012 and this TSD, will not cause or contribute to a violation of applicable federal regulations and Minnesota Rules.  Staff Members on Permit Team:  Tarik Hanafy (permit engineer) 

    Ladislaus Strzok (enforcement) Jim Kolar (compliance) Sarah Seelen (peer reviewer)  Beckie Olson (permit writing assistant) Sandra Simbeck (administrative support) 

     AQ File No. 2177; DQ 4517 (major), 4622 (major), 3164 (admin), 3206 (NESHAP subp. ZZZZZZ notification)  Attachments:   1.  Facility Description and CD‐01 Forms 

    2. Calculation Spreadsheets  3. Hood Certification Summary 4. Points Calculator 

  •      

    Attachment 1: Facility Description and CD01 Forms 

  • MINNESOTA POLLUTION CONTROL AGENCYAIR QUALITY520 LAFAYETTE ROADST. PAUL, MN 55155-4194

    Show:Action:AQD Facility ID:Facility Name:

    Active and Pending RecordsPER 01215700015Federal-Mogul Corp Powertrain Systems

    FACILITY DESCRIPTION: GROUPS (GP)

    12 November, 2014 10:00

    ID No. AddedBy

    (Action)

    RetiredBy

    (Action)

    Includein EI

    OperatorID

    for Item

    Group Description Group ItemsGroupStatus

    1 GP 001 PER 011 Charge Handling (2) and Induction Furnaces (6) EU 001, EU 004, EU 035, EU 041, EU 098, EU 099, EU 100, EU 131, EU 132,EU 165

    Active

    2 GP 002 PER 010 Fabric Filter-Low Temperature, i.e., T, 180 Degrees F - Applies to each CE CE 016, CE 017, SV 039, SV 040Active

    3 GP 002 PER 012 Fabric Filter-Low Temperature, i.e., T, 180 Degrees F - Applies to each CE CE 002, CE 015, CE 016, CE 017, SV 004, SV 030, SV 039, SV 040Active

    4 GP 003 PER 011 Industrial Process Equipment - Applies to each CE CE 005, CE 006, EU 012, EU 013, SV 007, SV 008Active

    5 GP 004 PER 011 Fabric Filter- Low Temperature, i.e., T,< 180 Degrees F - Applies to each CE CE 002, CE 011, EU 009, EU 129, EU 130, SV 004Active

    6 GP 004 PER 012 Fabric Filter- Low Temperature, i.e., T,< 180 Degrees F - Applies to each CERemoved

    7 GP 005 PER 010 RemovedActive

    8 GP 006 PER 010 Industrial Process Equipment - Applies to each EU EU 001, EU 043, EU 070, EU 098, EU 103, EU 131Active

    9 GP 007 PER 011 Centrifugal Casting Lines #1 and #2 Operation Group EU 001, EU 042, EU 043, EU 044, EU 047, EU 048, EU 049, EU 050, EU 051,EU 052, EU 053, EU 054, EU 055, EU 056, EU 057, EU 059, EU 060, EU 061,EU 062, EU 063, EU 064, EU 065, EU 066, EU 067, EU 068, EU 069, EU 070,EU 071, EU 074, EU 075, EU 076, EU 077, EU 078, EU 079, EU 080, EU 081,EU 082, EU 083, EU 086, EU 087, EU 088, EU 096, EU 097, EU 099, EU 100,EU 145, EU 146, EU 147, EU 148, EU 149, EU 150, EU 151

    Active

    10 GP 007 PER 012 Centrifugal Casting Lines #1 and #2 Operation Group EU 001, EU 042, EU 043, EU 044, EU 047, EU 048, EU 049, EU 052, EU 053,EU 054, EU 055, EU 056, EU 057, EU 059, EU 060, EU 061, EU 062, EU 063,EU 064, EU 065, EU 066, EU 067, EU 068, EU 069, EU 070, EU 071, EU 074,EU 075, EU 076, EU 079, EU 080, EU 081, EU 082, EU 083, EU 086, EU 087,EU 088, EU 096, EU 097, EU 099, EU 100, EU 145, EU 146, EU 147, EU 148,EU 149, EU 150, EU 151

    Active

    11 GP 008 PER 011 Direct Heating Equipment - Applies to each Emission Unit EU 023, EU 024, EU 026, EU 038, EU 040, EU 059, EU 060, EU 061, EU 062,EU 063, EU 064, EU 065, EU 066, EU 067, EU 068, EU 086, EU 087, EU 088,EU 119, EU 120, EU 121

    Active

    12 GP 009 PER 011 Centrifugal Casting Line #3 Operation Group and Shot Blast Cleaning of HPLCasting #3 (EU 130)

    CE 019, EU 098, EU 101, EU 102, EU 103, EU 104, EU 107, EU 108, EU 109,EU 110, EU 111, EU 112, EU 113, EU 114, EU 115, EU 116, EU 117, EU 118,EU 119, EU 120, EU 121, EU 131, EU 132, EU 133, EU 134, EU 135, EU 140,EU 154, SV 043, SV 044, SV 045

    Active

    13 GP 010 PER 010 Fabric Filters- Subject to CAM CE 002, CE 015, SV 004, SV 030Active

    14 GP 010 PER 012 Fabric Filters- Subject to CAMRemoved

    15 GP 011 PER 011 Boilers EU 033, EU 034, SV 028, SV 029Active

    16 GP 012 PER 011 Evaporators EU 136, EU 137, EU 138, EU 139, SV 046, SV 047, SV 048, SV 049Active

    17 GP 013 PER 011 40 CFR pt. 63, subp. ZZZZZ CE 015, CE 017, CE 019, CE 020, EU 004, EU 035, EU 041, EU 099, EU 100,EU 132, EU 165

    Active

    18 GP 014 PER 011 40 CFR pt. 63, subp. ZZZZZZ EU 024, SV 019Active

    Page 1 of 1

  • MINNESOTA POLLUTION CONTROL AGENCYAIR QUALITY520 LAFAYETTE ROADST. PAUL, MN 55155-4194

    Show: Active and Pending RecordsAction: PER 012AQD Facility ID: 15700015Facility Name: Federal-Mogul Corp Powertrain Systems

    12 November, 2014 10:01

    FACILITY DESCRIPTION: STACK/VENTS (SV)

    ID No. Discharge DirectionFlow Rate/Temperature

    Information Source

    Exit GasTemperature

    at Top(ºF)

    DesignFlow Rate

    at Top(ACFM)

    Width(feet)

    Diameteror Length

    (feet)

    Inside DimensionsHeight ofOpening

    FromGround(feet)

    AddedBy

    (Action)

    RetiredBy

    (Action)

    OperatorID

    for Item

    Operators DescriptionStack/Vent

    Status

    1 SV 001 Up, No CapEstimate90140002.540PER 011 CIF HighbayActive

    2 SV 002 Up, No CapEstimate90200002.540PER 011Removed

    3 SV 003 Up, No CapEstimate90140002.520PER 008Retired

    4 SV 004 Up, No CapEstimate100400002.645PER 008 Fabric Filter CE 002Active

    5 SV 005 Up, No CapEstimate9083552.5220PER 010 Fabric Filter CE 003Removed

    6 SV 006 Up, No CapEstimate8020001120PER 011Removed

    7 SV 007 Up, No CapEstimate901001.5120PER 008 Fabric Filter CE 005Active

    8 SV 008 Up, No CapEstimate901001.550PER 011 Fabric Filer CE 006Active

    9 SV 009 Up, No CapEstimate4001951130PER 002Removed

    10 SV 010 Up, No CapEstimate4001951130PER 002Removed

    11 SV 011 Up, No CapEstimate36002761.520PER 002Removed

    12 SV 012 Up, No CapTest18002761.520PER 002Removed

    13 SV 013 Up, No CapTest1038900140PER 011Removed

    14 SV 014 Up, No CapEstimate7511711.520PER 011 Machine Area General VentActive

    15 SV 015 Up, No CapEstimate4001951130PER 002Removed

    16 SV 016 Up, No CapEstimate901001.520PER 011Removed

    17 SV 017 Up, No CapTest743500120PER 011Removed

    18 SV 018 Up, No CapEstimate1001565120PER 011 Piston Heat TreatingActive

    19 SV 019 Up, No CapEstimate400902430PER 010 Aluminun Foundry Central Melting FurnaceActive

    20 SV 020 Up, No CapEstimate1308230130PER 011 Aluminum Foundry Vanisil Dross HopperActive

    21 SV 021 Up, No CapTest8013344330PER 011 Aluminum Foundry Holding FurnacesActive

    22 SV 022 Up, No CapEstimate808000220PER 011Removed

    23 SV 023 Up, No CapEstimate903323230PER 008 Fabric Filer CE 013Active

    24 SV 024 Up, No CapEstimate3001452330PER 011 Aluminum Chip DryingRetired

    25 SV 025 Up, No CapEstimate200500124PER 011 Peerless BoilerRetired

    26 SV 026 Up, No CapTest7625001.530PER 010 PlatingRemoved

    27 SV 027 Up, No CapEstimate200500124PER 011 Slant/Fin BoilerRetired

    Page 1 of 2

  • MINNESOTA POLLUTION CONTROL AGENCYAIR QUALITY520 LAFAYETTE ROADST. PAUL, MN 55155-4194

    Show: Active and Pending RecordsAction: PER 012AQD Facility ID: 15700015Facility Name: Federal-Mogul Corp Powertrain Systems

    12 November, 2014 10:01

    FACILITY DESCRIPTION: STACK/VENTS (SV)

    ID No. Discharge DirectionFlow Rate/Temperature

    Information Source

    Exit GasTemperature

    at Top(ºF)

    DesignFlow Rate

    at Top(ACFM)

    Width(feet)

    Diameteror Length

    (feet)

    Inside DimensionsHeight ofOpening

    FromGround(feet)

    AddedBy

    (Action)

    RetiredBy

    (Action)

    OperatorID

    for Item

    Operators DescriptionStack/Vent

    Status

    28 SV 028 Up, With CapEstimate400500.820PER 011 Bryan BoilerActive

    29 SV 029 Up, With CapEstimate300500.830PER 011 Weil-McLain BoilerActive

    30 SV 030 Up, No CapEstimate9050000440PER 011 Fabric Filter CE 015Active

    31 SV 031 Up, No CapTest2601360.8328PER 011 Aluminum Foundry Heat Treating Oven - sowActive

    32 SV 032 Up, No CapTest3051750.8327PER 011 Sleeve Machine Shop Heat Treating OvenActive

    33 SV 033 Up, No CapEstimate7015,000330PER 011 Die Coating Operations Line #1Active

    34 SV 034 Up, No CapEstimate7015,000331PER 011 Die Coating Operations Line #2Active

    35 SV 035 Up, No CapEstimate7015,000336PER 011 Nearest General Facility Vent for Die Preheating Burners Line #1Active

    36 SV 036 Up, No CapEstimate20015,000331PER 011 Exhaust Stack for Die Preheating Burners Line #2Active

    37 SV 037 PER 011 Centrifugal Pour & Cool Line #1Removed

    38 SV 038 Up, No CapPER 011 Centrifugal Pour & Cool Line #2Removed

    39 SV 039 Up, No CapEstimate8642,3205.560PER 011 Fabric Filter CE 016Active

    40 SV 040 Up, No CapEstimate10018000340PER 011 Fabric Filter CE 017Active

    41 SV 041 Up, No CapTest9954,350440PER 011 Fabric Filter CE 018Active

    42 SV 042 Up, No CapEstimate7015,000331PER 010 Nearest General Facility Vent for Die Coating Operations Line #3Active

    43 SV 043 Up, No CapEstimate10015,000231PER 011 Exhaust Stack for Die Preheating Burners Line #3Active

    44 SV 044 Up, No CapEstimate7015,000331PER 010 Centrifugal Line #3-Charge HandlingActive

    45 SV 045 Up, No CapEstimate9065,000560PER 011 Fabric Filter CE 019Active

    46 SV 046 Up, No CapManufacturer450520.7531PER 011 Evaporator #1 StackActive

    47 SV 047 Up, No CapManufacturer450520.7531PER 011 Evaporator #2 StackActive

    48 SV 048 Up, No CapManufacturer450520.7531PER 011 Evaporator #3 StackActive

    49 SV 049 Up, No CapManufacturer450520.7531PER 011 Evaporator #4 StackActive

    50 SV 050 Up, No CapEstimate7020,0002.3231PER 011 FM CGI Baghouse Stack (CE020)Active

    51 SV 051 Up, No CapEstimate7015,000421PER 011 Nearest Facility Vent for W/C 791Active

    52 SV 052 Up, No CapEstimate7015,000421PER 011 Nearest Facility Vent for W/C 791Active

    53 SV 053 Up, No CapManufacturer107629880.29212PER 012 Emergency GeneratorActive

    Page 2 of 2

  • MINNESOTA POLLUTION CONTROL AGENCYAIR QUALITY520 LAFAYETTE ROADST. PAUL, MN 55155-4194

    Show: Active and Pending RecordsAction: PER 012AQD Facility ID: 15700015Facility Name: Federal-Mogul Corp Powertrain Systems

    12 November, 2014 10:01

    FACILITY DESCRIPTION: CONTROL EQUIPMENT (CE)

    ID No. AddedBy

    (Action)

    RetiredBy

    (Action)

    OperatorID

    for Item

    Control

    Equip.Type

    Control Equipment Description ModelControlEquip.Status

    Manufacturer PollutantsControlled

    AfterburnerCombustionParameters

    CaptureEfficiency

    (%)

    Destruction/CollectionEfficiency

    (%)

    1 CE 001 PER 010 018 Fabric Filter - Low Temperature, i.e., T

  • MINNESOTA POLLUTION CONTROL AGENCYAIR QUALITY520 LAFAYETTE ROADST. PAUL, MN 55155-4194

    Show: Active and Pending RecordsAction: PER 012AQD Facility ID: 15700015Facility Name: Federal-Mogul Corp Powertrain Systems

    12 November, 2014 10:01

    FACILITY DESCRIPTION: CONTROL EQUIPMENT (CE)

    ID No. AddedBy

    (Action)

    RetiredBy

    (Action)

    OperatorID

    for Item

    Control

    Equip.Type

    Control Equipment Description ModelControlEquip.Status

    Manufacturer PollutantsControlled

    AfterburnerCombustionParameters

    CaptureEfficiency

    (%)

    Destruction/CollectionEfficiency

    (%)

    21 CE 021 PER 011 018 Fabric Filter - Low Temperature, i.e., T

  • ST. PAUL, MN 55155-4194

    Show: Active and Pending RecordsAction: PER 012AQD Facility ID: 15700015Facility Name:

    MINNESOTA POLLUTION CONTROL AGENCYAIR QUALITY520 LAFAYETTE ROAD

    12 November, 2014 10:02

    FACILITY DESCRIPTION: EMISSION UNIT (EU)

    MaxFuelInput

    (mil Btu)

    Federal-Mogul Corp Powertrain Systems

    RetiredBy

    (Action)

    Operator DescriptionID No. EmissionUnit

    Status

    AddedBy

    (Action)

    ControlEquip.

    ID No(s).

    Stack/Vent

    ID No(s).

    OperatorID

    for Item

    Insignif-icant

    Activity

    SICManufacturer ModelNumber

    Max.Design

    Capacity

    MaximumDesign

    Capacity

    Materials Units n Units d

    1 FM Charge Handling BridgeCrane

    EU 001 Active PER 011 SV 001 (M) Hr 3321Northern Engineering 10 Ton 10.25 Ton

    2 FM Charge Handling BridgeCrane - Material HandlingEquipment

    EU 001 Active PER 012 SV 001 (M) Hr 3321Northern Engineering 10 Ton 10.25 Ton

    4.83 Two Natural Gas FiredPreheater Buckets

    EU 002 Removed PER 011 Hr 3321Lindberg CF-53-C 9 Ton

    4 Two Existing CorelessInduction Furnaces

    EU 003 Removed EIS 001 Hr 3321Lindberg NFGe 10/2500 4 Ton

    5 FM Inductotherm CorelessFurnace #3

    EU 004 Active PER 011 CE 015SV 030 (M) Hr 3321Inductotherm Linemelt 2500 KW 2.3 Ton

    6 FM Inductotherm CorelessFurnace #3 - Furnace

    EU 004 Active PER 012 CE 015SV 030 (M) Hr 3321Inductotherm Linemelt 2500 KW 2.3 Ton

    7 High Pressure Molding LinePouring & Cooling

    EU 005 Removed PER 011 Hr 3321Inductotherm Linemelt Inductopour 5.7 Ton

    8 Match Blowmatic Molding LinePouring & Cooling

    EU 006 Removed EIS 001 Hr 3321Beardsley & Piper 85B .63 Ton

    9 High Pressure Molding LinePunchout

    EU 007 Active PER 011 CE 018SV 041 (M) Hr 3321KW NA 8.5 Ton

    10 High Pressure Molding LinePunchout - PressingEquipment

    EU 007 Active PER 012 CE 018SV 041 (M) Hr 3321KW NA 8.5 Ton

    11 FM Casting Conveying andCooling

    EU 008 Active PER 011 CE 018SV 041 (M) Hr 3321General Kinematics NA 8.5 Ton

    12 FM Casting Conveying andCooling - Conveyor

    EU 008 Active PER 012 CE 018SV 041 (M) Hr 3321General Kinematics NA 8.5 Ton

    13 Shotblast Cleaning of Castings#1

    EU 009 Active PER 011 CE 002SV 004 (M) Hr 3321Wheelabrator 28 Cubic Feet 2.92 Ton

    14 Shotblast Cleaning of Castings#1 - Abrasive Equipment

    EU 009 Active PER 012 CE 002SV 004 (M) Hr 3321Wheelabrator 28 Cubic Feet 2.92 Ton

    15 Tumble Cleaning of CastingsEU 010 Removed PER 011 SV 006 (M) Hr 3321Wheelabrator 14 Cubic Feet 6.33 Ton

    16 Foundry Sand MullerEU 011 Active PER 011 CE 018SV 041 (M) Hr 3321Beardsley & Piper 85B 0.881 Ton

    17 Foundry Sand Muller -Sanding Equipment

    EU 011 Active PER 012 CE 018SV 041 (M) Hr 3321Beardsley & Piper 85B 0.881 Ton

    18 Sand Receiving SiloEU 012 Active EIS 001 CE 005SV 007 (M) Hr 3321Custom 100 Ton 6 Ton

    19 Sand Receiving Silo - Silo/BinEU 012 Active PER 012 CE 005SV 007 (M) Hr 3321Custom 100 Ton 6 Ton

    Page 1 of 17 (a)

  • 12 November, 2014 10:02

    FACILITY DESCRIPTION: EMISSION UNIT (EU)

    ID No. ElevatorType

    BottleneckPct.Fuel/

    SpaceHeat

    Firing MethodAddedBy

    (Action)

    RemovalDate

    InitialStartup

    Date

    Comm-ence

    Const.Date

    EmissionUnit

    Status

    1 EU 001 PER 011 01/01/197901/01/1979Active

    2 EU 001 PER 012 01/01/197901/01/1979Active

    3 EU 002 0PER 011 12/31/200401/01/197901/01/1979Removed

    4 EU 003 EIS 001 12/31/199801/01/197901/01/1979Removed

    5 EU 004 PER 011 11/01/199410/01/1994Active

    6 EU 004 PER 012 11/01/199410/01/1994Active

    7 EU 005 PER 011 12/31/200202/01/198801/01/1988Removed

    8 EU 006 EIS 001 12/31/199802/01/199001/01/1990Removed

    9 EU 007 PER 011 02/01/198601/01/1986Active

    10 EU 007 PER 012 02/01/198601/01/1986Active

    11 EU 008 PER 011 02/01/198601/01/1986Active

    12 EU 008 PER 012 02/01/198601/01/1986Active

    13 EU 009 PER 011 02/01/197901/01/1979Active

    14 EU 009 PER 012 02/01/197901/01/1979Active

    15 EU 010 PER 011 12/31/199802/01/197901/01/1979Removed

    16 EU 011 PER 011 02/01/198801/01/1988Active

    17 EU 011 PER 012 02/01/198801/01/1988Active

    18 EU 012 EIS 001 01/01/197901/01/1979Active

    19 EU 012 PER 012 01/01/197901/01/1979Active

    Page 1 of 17 (b)

  • ST. PAUL, MN 55155-4194

    Show: Active and Pending RecordsAction: PER 012AQD Facility ID: 15700015Facility Name:

    MINNESOTA POLLUTION CONTROL AGENCYAIR QUALITY520 LAFAYETTE ROAD

    12 November, 2014 10:02

    FACILITY DESCRIPTION: EMISSION UNIT (EU)

    MaxFuelInput

    (mil Btu)

    Federal-Mogul Corp Powertrain Systems

    RetiredBy

    (Action)

    Operator DescriptionID No. EmissionUnit

    Status

    AddedBy

    (Action)

    ControlEquip.

    ID No(s).

    Stack/Vent

    ID No(s).

    OperatorID

    for Item

    Insignif-icant

    Activity

    SICManufacturer ModelNumber

    Max.Design

    Capacity

    MaximumDesign

    Capacity

    Materials Units n Units d

    20 Sand Receiving SiloEU 013 Active PER 011 CE 006CE 015

    SV 008 (M)SV 030 (P)

    Hr 3321Custom 100 Ton 6 Ton

    21 Sand Receiving Silo - Silo/BinEU 013 Active PER 012 CE 006CE 015

    SV 008 (M)SV 030 (P)

    Hr 3321Custom 100 Ton 6 Ton

    22 Isocure Core MakingEU 014 Removed EIS 001 Hr 3321Shalco U180 CB .45 Ton

    23 Isocure Core MakingEU 015 Removed EIS 001 Hr 3321Shalco 4-101 .45 Ton

    224 Core OvenEU 016 Removed EIS 001 Hr 3321Despatch DO500 Type ILA1 .67 Ton

    125 Core OvenEU 017 Removed EIS 001 Hr 3321Despatch DO100 .33 Ton

    6.426 Gray Iron Chip DryerEU 018 Removed EIS 001 SV 013 (M) Hr 3321Lindberg RCD-4000 2 Ton

    4.827 Gray Iron Heat Treating OvenEU 019 Removed PER 010 3321Johnston 4x16x4 Car Type

    828 CO2 Core MakingEU 020 Removed EIS 001 Hr 3321Custom NA .25 Ton

    29 Pepset Sand SystemEU 021 Removed EIS 003 SV 016 (M) Hr 3321NA NA 1.2 Ton

    30 Pepset Mold Making SystemEU 022 Removed PER 003 Min 3321Strong Skott for mixer NA 3450 Ft3(s)

    131 Aluminum Heat TreatingEU 023 Active PER 011 SV 018 (M) 3321Despatch NA

    132 Aluminum Heat Treating -Other Combustion

    EU 023 Active PER 012 SV 018 (M) 3321Despatch NA

    5.06633 Aluminum Foundry CentralMelting Furnace

    EU 024 Active PER 011 SV 019 (M) Hr 3321MPH ACM-2500-OP .83 Ton

    5.06634 Aluminum Foundry CentralMelting Furnace - Furnace

    EU 024 Active PER 012 SV 019 (M) Hr 3321MPH ACM-2500-OP .83 Ton

    835 Aluminum Foundry HoldingCrucibles

    EU 025 Removed PER 011 Hr 3321Lindberg NA .15 Ton

    836 Aluminum Foundry HoldingFurnaces

    EU 026 Active PER 011 SV 021 (P) Hr 3321F W Schafer NA .15 Ton

    837 Aluminum Foundry HoldingFurnaces - Furnace

    EU 026 Active PER 012 SV 021 (P) Hr 3321F W Schafer NA .15 Ton

    38 Spraying Mold Release onLiqui-Forge Molds

    EU 027 Removed EIS 001 SV 022 (M) Yr 3321NA NA 240000 Ft3

    39 Cleaning Aluminum Castings(Cutting)

    EU 028 Retired PER 011 Hr 3321Custom NA .83 Ton

    5.240 Aluminum Chip DryingEU 029 Removed PER 011 SV 024 (M) Hr 3321Coreco NA 1 Ton

    41 BoilerEU 030 Removed PER 011 3321Burnham

    42 PlatingEU 031 Removed PER 011 Min 3321Clinton Supply Co NA 2500 Ft3(s)

    Page 2 of 17 (a)

  • 12 November, 2014 10:02

    FACILITY DESCRIPTION: EMISSION UNIT (EU)

    ID No. ElevatorType

    BottleneckPct.Fuel/

    SpaceHeat

    Firing MethodAddedBy

    (Action)

    RemovalDate

    InitialStartup

    Date

    Comm-ence

    Const.Date

    EmissionUnit

    Status

    20 EU 013 PER 011 01/01/197901/01/1979Active

    21 EU 013 PER 012 01/01/197901/01/1979Active

    22 EU 014 EIS 001 12/31/199801/01/197901/01/1979Removed

    23 EU 015 EIS 001 12/31/199801/01/197901/01/1979Removed

    24 EU 016 0EIS 001 12/31/199801/01/197901/01/1979Removed

    25 EU 017 0EIS 001 12/31/199801/01/197901/01/1979Removed

    26 EU 018 0EIS 001 12/31/199801/01/197901/01/1979Removed

    27 EU 019 0PER 010 08/01/200301/01/197901/01/1979Removed

    28 EU 020 0EIS 001 12/31/199801/01/197501/01/1975Removed

    29 EU 021 EIS 003 12/31/199901/01/198001/01/1980Removed

    30 EU 022 PER 003 10/01/199901/01/198001/01/1980Removed

    31 EU 023 0PER 011 01/01/197501/01/1975Active

    32 EU 023 0PER 012 01/01/197501/01/1975Active

    33 EU 024 0PER 011 07/01/199005/15/1990Active

    34 EU 024 0PER 012 07/01/199005/15/1990Active

    35 EU 025 0PER 011 01/01/199801/01/196801/01/1968Removed

    36 EU 026 0PER 011 01/01/197801/01/1978Active

    37 EU 026 0PER 012 01/01/197801/01/1978Active

    38 EU 027 EIS 001 12/31/199801/01/198601/01/1986Removed

    39 EU 028 PER 011 01/01/196001/01/1960Retired

    40 EU 029 0PER 011 02/01/200301/01/197801/01/1978Removed

    41 EU 030 0PER 011 02/28/200703/01/199903/01/1999Removed

    42 EU 031 PER 011 02/28/200701/01/194501/01/1945Removed

    Page 2 of 17 (b)

  • ST. PAUL, MN 55155-4194

    Show: Active and Pending RecordsAction: PER 012AQD Facility ID: 15700015Facility Name:

    MINNESOTA POLLUTION CONTROL AGENCYAIR QUALITY520 LAFAYETTE ROAD

    12 November, 2014 10:02

    FACILITY DESCRIPTION: EMISSION UNIT (EU)

    MaxFuelInput

    (mil Btu)

    Federal-Mogul Corp Powertrain Systems

    RetiredBy

    (Action)

    Operator DescriptionID No. EmissionUnit

    Status

    AddedBy

    (Action)

    ControlEquip.

    ID No(s).

    Stack/Vent

    ID No(s).

    OperatorID

    for Item

    Insignif-icant

    Activity

    SICManufacturer ModelNumber

    Max.Design

    Capacity

    MaximumDesign

    Capacity

    Materials Units n Units d

    1.743 BoilerEU 032 Removed PER 010 SV 025 (M) 3321Weil-McLain LBG-10

    .3844 BoilerEU 033 Active PER 011 SV 028 (M) Hr Heat3321Bryan CL-24-ST .38 Mmbtu

    .3845 Boiler - BoilerEU 033 Active PER 012 SV 028 (M) Hr Heat3321Bryan CL-24-ST .38 Mmbtu

    .4546 BoilerEU 034 Active PER 011 SV 029 (M) Hr Heat3321Weil-McLain LG-6 .45 Mmbtu

    .4547 Boiler - BoilerEU 034 Active PER 012 SV 029 (M) Hr Heat3321Weil-McLain LG-6 .45 Mmbtu

    48 FM Inductotherm CorelessFurnace #2

    EU 035 Active PER 011 CE 015SV 030 (M) Hr 3321ABB IFM-6 7.00 Ton

    49 FM Inductotherm CorelessFurnace #2 - Furnace

    EU 035 Active PER 012 CE 015SV 030 (M) Hr 3321ABB IFM-6 7.00 Ton

    50 High Pressure Molding LinePouring & Cooling

    EU 036 Active PER 011 CE 015SV 030 (M) Hr 3321Kunkel Wagner EPM 8.50 Ton

    51 High Pressure Molding LinePouring & Cooling - PouringEquipment

    EU 036 Active PER 012 CE 015SV 030 (M) Hr 3321Kunkel Wagner EPM 8.50 Ton

    52 Tumble Cleaning of CastingsEU 037 Removed PER 010 CE 002SV 004 Hr 3321Didion 16.25 Ton

    0.353 Aluminum Foundry HeatTreating Oven - SOW

    EU 038 Active PER 011 SV 031 (M) Hr Heat3321Despatch PWE3-15-16 0.3 Mmbtu

    0.354 Aluminum Foundry HeatTreating Oven - SOW -Dryer/Oven, unknown firingmethod

    EU 038 Active PER 012 SV 031 (M) Hr Heat3321Despatch PWE3-15-16 0.3 Mmbtu

    55 BoilerEU 039 Removed PER 011 3321Slant/Fin GG399

    0.7556 Sleeve Machine Shop TreatingOven

    EU 040 Active PER 011 SV 032 (M) Hr Heat3321Despatch PSD3-495-G 0.75 Mmbtu

    0.7557 Sleeve Machine Shop TreatingOven - Other Emission Unit

    EU 040 Active PER 012 SV 032 (M) Hr Heat3321Despatch PSD3-495-G 0.75 Mmbtu

    58 FM Inductotherm CorelessFurnace #1

    EU 041 Active PER 011 CE 015SV 030 (M) Hr 3321ABB IFM-6 7.00 Ton

    59 FM Inductotherm CorelessFurnace #1 - Furnace

    EU 041 Active PER 012 CE 015SV 030 (M) Hr 3321ABB IFM-6 7.00 Ton

    60 Air Blowout Gun Line 1EU 042 Active PER 011 CE 015SV 030 (M) Hr 3321Guardair 75XT 32.34 Lb

    61 Air Blowout Gun Line 1 -Blowing Equipment

    EU 042 Active PER 012 CE 015SV 030 (M) Hr 3321Guardair 75XT 32.34 Lb

    62 Coating Application Wand Line1

    EU 043 Active PER 011 SV 033 (M) Hr 3321Federal-Mogul 70140200 32.34 Lb

    Page 3 of 17 (a)

  • 12 November, 2014 10:02

    FACILITY DESCRIPTION: EMISSION UNIT (EU)

    ID No. ElevatorType

    BottleneckPct.Fuel/

    SpaceHeat

    Firing MethodAddedBy

    (Action)

    RemovalDate

    InitialStartup

    Date

    Comm-ence

    Const.Date

    EmissionUnit

    Status

    43 EU 032 100PER 010 12/31/199801/01/194501/01/1945Removed

    44 EU 033 100PER 011 01/01/197001/01/1970Active

    45 EU 033 100PER 012 01/01/197001/01/1970Active

    46 EU 034 100PER 011 01/01/194301/01/1943Active

    47 EU 034 100PER 012 01/01/194301/01/1943Active

    48 EU 035 PER 011 12/01/199906/29/1999Active

    49 EU 035 PER 012 12/01/199906/29/1999Active

    50 EU 036 PER 011 12/01/199906/29/1999Active

    51 EU 036 PER 012 12/01/199906/29/1999Active

    52 EU 037 PER 010 12/31/2002Removed

    53 EU 038 PER 011 01/15/200101/01/2001Active

    54 EU 038 PER 012 01/15/200101/01/2001Active

    55 EU 039 100PER 011 02/28/2007Removed

    56 EU 040 PER 011Active

    57 EU 040 PER 012Active

    58 EU 041 PER 011 12/01/199906/29/1999Active

    59 EU 041 PER 012 12/01/199906/29/1999Active

    60 EU 042 PER 011 09/01/200006/26/2000Active

    61 EU 042 PER 012 09/01/200006/26/2000Active

    62 EU 043 PER 011 09/01/200006/26/2000Active

    Page 3 of 17 (b)

  • ST. PAUL, MN 55155-4194

    Show: Active and Pending RecordsAction: PER 012AQD Facility ID: 15700015Facility Name:

    MINNESOTA POLLUTION CONTROL AGENCYAIR QUALITY520 LAFAYETTE ROAD

    12 November, 2014 10:02

    FACILITY DESCRIPTION: EMISSION UNIT (EU)

    MaxFuelInput

    (mil Btu)

    Federal-Mogul Corp Powertrain Systems

    RetiredBy

    (Action)

    Operator DescriptionID No. EmissionUnit

    Status

    AddedBy

    (Action)

    ControlEquip.

    ID No(s).

    Stack/Vent

    ID No(s).

    OperatorID

    for Item

    Insignif-icant

    Activity

    SICManufacturer ModelNumber

    Max.Design

    Capacity

    MaximumDesign

    Capacity

    Materials Units n Units d

    63 Coating Application Wand Line1 - Spray Booth/Coating Line

    EU 043 Active PER 012 SV 033 (M) Hr 3321Federal-Mogul 70140200 32.34 Lb

    64 Line #1 Long Tube AbrasiveBlasting Unit

    EU 044 Active PER 011 CE 015SV 030 (M) Hr 3321US Filter/Wheelabrator 6 1.75 Ton

    65 Line #1 Long Tube AbrasiveBlasting Unit - AbrasiveEquipment

    EU 044 Active PER 012 CE 015SV 030 (M) Hr 3321US Filter/Wheelabrator 6 1.75 Ton

    66 Abrasive Blasting Unit #2EU 045 Removed PER 011 Hr Casting3321US Filter/Wheelabrator 7 26 Each

    67 Abrasive Blasting Unit #3EU 046 Removed PER 011 Hr Casting3321US Filter/Wheelabrator 7 26 Each

    68 Casting Cutting Station 1-1EU 047 Active PER 011 CE 015SV 030 (M) Hr 3321Yasec Yamashino Seik OL 0.35 Ton

    69 Casting Cutting Station 1-1 -Casting Equipment

    EU 047 Active PER 012 CE 015SV 030 (M) Hr 3321Yasec Yamashino Seik OL 0.35 Ton

    70 Casting Cutting Station 1-2EU 048 Active PER 011 CE 015SV 030 (M) Hr 3321Yasec Yamashino Seik OL 0.35 Ton

    71 Casting Cutting Station 1-2 -Casting Equipment

    EU 048 Active PER 012 CE 015SV 030 (M) Hr 3321Yasec Yamashino Seik OL 0.35 Ton

    72 Casting Cutting Station 1-3EU 049 Active PER 011 CE 015SV 030 (M) Hr 3321Yasec Yamashino Seik OL 0.35 Ton

    73 Casting Cutting Station 1-3 -Casting Equipment

    EU 049 Active PER 012 CE 015SV 030 (M) Hr 3321Yasec Yamashino Seik OL 0.35 Ton

    74 Casting Cutting Station 1-4EU 050 Active PER 011 CE 015SV 030 (M) Hr 3321Yasec Yamashino Seik OL 0.35 Ton

    75 Casting Cutting Station 1-4EU 050 Removed PER 012 Hr 3321Yasec Yamashino Seik OL 0.35 Ton

    76 Casting Cutting Station 1-5EU 051 Active PER 011 CE 015SV 030 (M) Hr 3321Yasec Yamashino Seik OL 0.35 Ton

    77 Casting Cutting Station 1-5EU 051 Removed PER 012 Hr 3321Yasec Yamashino Seik OL 0.35 Ton

    78 Machining Lathe 1-1EU 052 Active PER 011 CE 015SV 030 (M) Hr 3321Okuma Lathes LU-25 0.3182 Ton

    79 Machining Lathe 1-1 -Machining Equipment

    EU 052 Active PER 012 CE 016SV 039 (M) Hr 3321Okuma Lathes LU-25 0.3182 Ton

    80 Machining Lathe 1-2EU 053 Active PER 011 CE 015SV 030 (M) Hr 3321Okuma Lathes LU-25 0.3182 Ton

    81 Machining Lathe 1-2 -Machining Equipment

    EU 053 Active PER 012 CE 016SV 039 (M) Hr 3321Okuma Lathes LU-25 0.3182 Ton

    82 Machining Lathe 1-3EU 054 Active PER 011 CE 015SV 030 (M) Hr 3321Okuma Lathes LU-25 0.3182 Ton

    83 Machining Lathe 1-3 -Machining Equipment

    EU 054 Active PER 012 CE 016SV 039 (M) Hr 3321Okuma Lathes LU-25 0.3182 Ton

    84 Machining Lathe 1-4EU 055 Active PER 011 CE 015SV 030 (M) Hr 3321Okuma Lathes LU-25 0.3182 Ton

    Page 4 of 17 (a)

  • 12 November, 2014 10:02

    FACILITY DESCRIPTION: EMISSION UNIT (EU)

    ID No. ElevatorType

    BottleneckPct.Fuel/

    SpaceHeat

    Firing MethodAddedBy

    (Action)

    RemovalDate

    InitialStartup

    Date

    Comm-ence

    Const.Date

    EmissionUnit

    Status

    63 EU 043 PER 012 09/01/200006/26/2000Active

    64 EU 044 PER 011 09/01/200006/26/2000Active

    65 EU 044 PER 012 09/01/200006/26/2000Active

    66 EU 045 PER 011 11/30/200709/01/200006/26/2000Removed

    67 EU 046 PER 011 11/30/200709/01/200006/26/2000Removed

    68 EU 047 PER 011 09/01/200006/26/2000Active

    69 EU 047 PER 012 09/01/200006/26/2000Active

    70 EU 048 PER 011 09/01/200006/26/2000Active

    71 EU 048 PER 012 09/01/200006/26/2000Active

    72 EU 049 PER 011 09/01/200006/26/2000Active

    73 EU 049 PER 012 09/01/200006/26/2000Active

    74 EU 050 PER 011 09/01/200006/26/2000Active

    75 EU 050 PER 012 09/01/200006/26/2000Removed

    76 EU 051 PER 011 09/01/200006/26/2000Active

    77 EU 051 PER 012 09/01/200006/26/2000Removed

    78 EU 052 PER 011 09/01/200006/26/2000Active

    79 EU 052 PER 012 09/01/200006/26/2000Active

    80 EU 053 PER 011 09/01/200006/26/2000Active

    81 EU 053 PER 012 09/01/200006/26/2000Active

    82 EU 054 PER 011 09/01/200006/26/2000Active

    83 EU 054 PER 012 09/01/200006/26/2000Active

    84 EU 055 PER 011 09/01/200006/26/2000Active

    Page 4 of 17 (b)

  • ST. PAUL, MN 55155-4194

    Show: Active and Pending RecordsAction: PER 012AQD Facility ID: 15700015Facility Name:

    MINNESOTA POLLUTION CONTROL AGENCYAIR QUALITY520 LAFAYETTE ROAD

    12 November, 2014 10:02

    FACILITY DESCRIPTION: EMISSION UNIT (EU)

    MaxFuelInput

    (mil Btu)

    Federal-Mogul Corp Powertrain Systems

    RetiredBy

    (Action)

    Operator DescriptionID No. EmissionUnit

    Status

    AddedBy

    (Action)

    ControlEquip.

    ID No(s).

    Stack/Vent

    ID No(s).

    OperatorID

    for Item

    Insignif-icant

    Activity

    SICManufacturer ModelNumber

    Max.Design

    Capacity

    MaximumDesign

    Capacity

    Materials Units n Units d

    85 Machining Lathe 1-4 -Machining Equipment

    EU 055 Active PER 012 CE 016SV 039 (M) Hr 3321Okuma Lathes LU-25 0.3182 Ton

    86 Brushing Unit Machine Line1-1

    EU 056 Active PER 011 CE 016SV 039 (M) Hr 3321Yoshida Unit 1 0.875 Ton

    87 Brushing Unit Machine Line1-1 - Abrasive Equipment

    EU 056 Active PER 012 CE 016SV 039 (M) Hr 3321Yoshida Unit 1 0.875 Ton

    88 Brushing Unit Machine Line2-1

    EU 057 Active PER 011 CE 016SV 039 (M) Hr 3321Yoshida Unit 2 0.875 Ton

    89 Brushing Unit Machine Line2-1 - Abrasive Equipment

    EU 057 Active PER 012 CE 016SV 039 (M) Hr 3321Yoshida Unit 2 0.875 Ton

    90 Line #1 Casting FinishingStation #7

    EU 058 Removed PER 011 Hr 3321Okuma Lathes LR25 97 Each

    0.158791 Die Heater Burner 1-1EU 059 Active PER 011 SV 035 (M) Hr Heat3321North American Mfg. C ISD-8312 0.1587 Mmbtu

    0.158792 Die Heater Burner 1-1 -Process Heater

    EU 059 Active PER 012 SV 035 (M) Hr Heat3321North American Mfg. C ISD-8312 0.1587 Mmbtu

    0.158793 Die Heater Burner 1-2EU 060 Active PER 011 SV 035 (M) Hr Heat3321North American Mfg. C ISD-8312 0.1587 Mmbtu

    0.158794 Die Heater Burner 1-2 -Process Heater

    EU 060 Active PER 012 SV 035 (M) Hr Heat3321North American Mfg. C ISD-8312 0.1587 Mmbtu

    0.158795 Die Heater Burner 1-3EU 061 Active PER 011 SV 035 (M) Hr Heat3321North American Mfg. C ISD-8312 0.1587 Mmbtu

    0.158796 Die Heater Burner 1-3 -Process Heater

    EU 061 Active PER 012 SV 035 (M) Hr Heat3321North American Mfg. C ISD-8312 0.1587 Mmbtu

    0.158797 Die Heater Burner 1-4EU 062 Active PER 011 SV 035 (M) Hr Heat3321North American Mfg. C ISD-8312 0.1587 Mmbtu

    0.158798 Die Heater Burner 1-4 -Process Heater

    EU 062 Active PER 012 SV 035 (M) Hr Heat3321North American Mfg. C ISD-8312 0.1587 Mmbtu

    0.158799 Die Heater Burner 1-5EU 063 Active PER 011 SV 035 (M) Hr Heat3321North American Mfg. C ISD-8312 0.1587 Mmbtu

    0.1587100 Die Heater Burner 1-5 -Process Heater

    EU 063 Active PER 012 SV 035 (M) Hr Heat3321North American Mfg. C ISD-8312 0.1587 Mmbtu

    0.1587101 Die Heater Burner 1-6EU 064 Active PER 011 SV 035 (M) Hr Heat3321North American Mfg. C ISD-8312 0.1587 Mmbtu

    0.1587102 Die Heater Burner 1-6 -Process Heater

    EU 064 Active PER 012 SV 035 (M) Hr Heat3321North American Mfg. C ISD-8312 0.1587 Mmbtu

    0.1587103 Die Heater Burner 1-7EU 065 Active PER 011 SV 035 (M) Hr Heat3321North American Mfg. C ISD-8312 0.1587 Mmbtu

    0.1587104 Die Heater Burner 1-7 -Process Heater

    EU 065 Active PER 012 SV 035 (M) Hr Heat3321North American Mfg. C ISD-8312 0.1587 Mmbtu

    0.1587105 Die Heater Burner 1-8EU 066 Active PER 011 SV 035 (M) Hr Heat3321North American Mfg. C ISD-8312 0.1587 Mmbtu

    Page 5 of 17 (a)

  • 12 November, 2014 10:02

    FACILITY DESCRIPTION: EMISSION UNIT (EU)

    ID No. ElevatorType

    BottleneckPct.Fuel/

    SpaceHeat

    Firing MethodAddedBy

    (Action)

    RemovalDate

    InitialStartup

    Date

    Comm-ence

    Const.Date

    EmissionUnit

    Status

    85 EU 055 PER 012 09/01/200006/26/2000Active

    86 EU 056 PER 011 09/01/200006/26/2000Active

    87 EU 056 PER 012 09/01/200006/26/2000Active

    88 EU 057 PER 011 09/01/200006/26/2000Active

    89 EU 057 PER 012 09/01/200006/26/2000Active

    90 EU 058 PER 011 11/30/200709/01/200006/26/2000Removed

    91 EU 059 PER 011 09/01/200006/26/2000Active

    92 EU 059 PER 012 09/01/200006/26/2000Active

    93 EU 060 PER 011 09/01/200006/26/2000Active

    94 EU 060 PER 012 09/01/200006/26/2000Active

    95 EU 061 PER 011 09/01/200006/26/2000Active

    96 EU 061 PER 012 09/01/200006/26/2000Active

    97 EU 062 PER 011 09/01/200006/26/2000Active

    98 EU 062 PER 012 09/01/200006/26/2000Active

    99 EU 063 PER 011 09/01/200006/26/2000Active

    100 EU 063 PER 012 09/01/200006/26/2000Active

    101 EU 064 PER 011 09/01/200006/26/2000Active

    102 EU 064 PER 012 09/01/200006/26/2000Active

    103 EU 065 PER 011 09/01/200006/26/2000Active

    104 EU 065 PER 012 09/01/200006/26/2000Active

    105 EU 066 PER 011 09/01/200006/26/2000Active

    Page 5 of 17 (b)

  • ST. PAUL, MN 55155-4194

    Show: Active and Pending RecordsAction: PER 012AQD Facility ID: 15700015Facility Name:

    MINNESOTA POLLUTION CONTROL AGENCYAIR QUALITY520 LAFAYETTE ROAD

    12 November, 2014 10:02

    FACILITY DESCRIPTION: EMISSION UNIT (EU)

    MaxFuelInput

    (mil Btu)

    Federal-Mogul Corp Powertrain Systems

    RetiredBy

    (Action)

    Operator DescriptionID No. EmissionUnit

    Status

    AddedBy

    (Action)

    ControlEquip.

    ID No(s).

    Stack/Vent

    ID No(s).

    OperatorID

    for Item

    Insignif-icant

    Activity

    SICManufacturer ModelNumber

    Max.Design

    Capacity

    MaximumDesign

    Capacity

    Materials Units n Units d

    0.1587106 Die Heater Burner 1-8 -Process Heater

    EU 066 Active PER 012 SV 035 (M) Hr Heat3321North American Mfg. C ISD-8312 0.1587 Mmbtu

    0.1587107 Die Heater Burner 1-9EU 067 Active PER 011 SV 035 (M) Hr Heat3321North American Mfg. C ISD-8312 0.1587 Mmbtu

    0.1587108 Die Heater Burner 1-9 -Process Heater

    EU 067 Active PER 012 SV 035 (M) Hr Heat3321North American Mfg. C ISD-8312 0.1587 Mmbtu

    0.1587109 Die Heater Burner 1-10EU 068 Active PER 011 SV 035 (M) Hr Heat3321North American Mfg. C ISD-8312 0.1587 Mmbtu

    0.1587110 Die Heater Burner 1-10 -Process Heater

    EU 068 Active PER 012 SV 035 (M) Hr Heat3321North American Mfg. C ISD-8312 0.1587 Mmbtu

    111 Air Blowout Gun Line 2EU 069 Active PER 011 CE 016SV 039 (M) Hr 3321Guardair 75XT 32.34 Lb

    112 Air Blowout Gun Line 2 -Blowing Equipment

    EU 069 Active PER 012 CE 016SV 039 (M) Hr 3321Guardair 75XT 32.34 Lb

    113 Coating Application Wand Line2

    EU 070 Active PER 011 CE 016SV 039 (M) Hr 3321Federal-Mogul 70140200 32.34 Lb

    114 Coating Application Wand Line2 - Spray Booth/Coating Line

    EU 070 Active PER 012 CE 016SV 039 (M) Hr 3321Federal-Mogul 70140200 32.34 Lb

    115 Line #2 Abrasive Blasting Unit#1 Long Tube

    EU 071 Active PER 011 CE 016SV 039 (M) Hr 3321US Filter/Wheelabrator 6 1.75 Ton

    116 Line #2 Abrasive Blasting Unit#1 Long Tube - AbrasiveEquipment

    EU 071 Active PER 012 CE 016SV 039 (M) Hr 3321US Filter/Wheelabrator 6 1.75 Ton

    117 Line #2 Abrasive Blasting Unit#2

    EU 072 Removed PER 011 Hr Casting3321US Filter/Wheelabrator 7 26 Each

    118 Line #2 Abrasive Blasting Unit#3

    EU 073 Removed PER 011 Hr Casting3321US Filter/Wheelabrator 7 26 Each

    119 Casting Cutting Station 2-1EU 074 Active PER 011 CE 016SV 039 (M) Hr 3321Yasec Yamashino Seik OL 0.35 Ton

    120 Casting Cutting Station 2-1 -Casting Equipment

    EU 074 Active PER 012 CE 016SV 039 (M) Hr 3321Yasec Yamashino Seik OL 0.35 Ton

    121 Casting Cutting Station 2-2EU 075 Active PER 011 CE 016SV 039 (M) Hr 3321Yasec Yamashino Seik OL 0.35 Ton

    122 Casting Cutting Station 2-2 -Casting Equipment

    EU 075 Active PER 012 CE 016SV 039 (M) Hr 3321Yasec Yamashino Seik OL 0.35 Ton

    123 Casting Cutting Station 2-3EU 076 Active PER 011 CE 016SV 039 (M) Hr 3321Yasec Yamashino Seik OL 0.35 Ton

    124 Casting Cutting Station 2-3 -Casting Equipment

    EU 076 Active PER 012 CE 016SV 039 (M) Hr 3321Yasec Yamashino Seik OL 0.35 Ton

    125 Casting Cutting Station 2-4EU 077 Active PER 011 CE 016SV 039 (M) Hr 3321Yasec Yamashino Seik OL 0.35 Ton

    126 Casting Cutting Station 2-4EU 077 Removed PER 012 Hr 3321Yasec Yamashino Seik OL 0.35 Ton

    Page 6 of 17 (a)

  • 12 November, 2014 10:02

    FACILITY DESCRIPTION: EMISSION UNIT (EU)

    ID No. ElevatorType

    BottleneckPct.Fuel/

    SpaceHeat

    Firing MethodAddedBy

    (Action)

    RemovalDate

    InitialStartup

    Date

    Comm-ence

    Const.Date

    EmissionUnit

    Status

    106 EU 066 PER 012 09/01/200006/26/2000Active

    107 EU 067 PER 011 09/01/200006/26/2000Active

    108 EU 067 PER 012 09/01/200006/26/2000Active

    109 EU 068 PER 011 09/01/200006/26/2000Active

    110 EU 068 PER 012 09/01/200006/26/2000Active

    111 EU 069 PER 011 12/01/200304/01/2003Active

    112 EU 069 PER 012 12/01/200304/01/2003Active

    113 EU 070 PER 011 12/01/200304/01/2003Active

    114 EU 070 PER 012 12/01/200304/01/2003Active

    115 EU 071 PER 011 12/01/200304/01/2003Active

    116 EU 071 PER 012 12/01/200304/01/2003Active

    117 EU 072 PER 011 11/30/200712/01/200304/01/2003Removed

    118 EU 073 PER 011 11/30/200712/01/200304/01/2003Removed

    119 EU 074 PER 011 12/01/200304/01/2003Active

    120 EU 074 PER 012 12/01/200304/01/2003Active

    121 EU 075 PER 011 12/01/200304/01/2003Active

    122 EU 075 PER 012 12/01/200304/01/2003Active

    123 EU 076 PER 011 12/01/200304/01/2003Active

    124 EU 076 PER 012 12/01/200304/01/2003Active

    125 EU 077 PER 011 12/01/200304/01/2003Active

    126 EU 077 PER 012 12/01/200304/01/2003Removed

    Page 6 of 17 (b)

  • ST. PAUL, MN 55155-4194

    Show: Active and Pending RecordsAction: PER 012AQD Facility ID: 15700015Facility Name:

    MINNESOTA POLLUTION CONTROL AGENCYAIR QUALITY520 LAFAYETTE ROAD

    12 November, 2014 10:02

    FACILITY DESCRIPTION: EMISSION UNIT (EU)

    MaxFuelInput

    (mil Btu)

    Federal-Mogul Corp Powertrain Systems

    RetiredBy

    (Action)

    Operator DescriptionID No. EmissionUnit

    Status

    AddedBy

    (Action)

    ControlEquip.

    ID No(s).

    Stack/Vent

    ID No(s).

    OperatorID

    for Item

    Insignif-icant

    Activity

    SICManufacturer ModelNumber

    Max.Design

    Capacity

    MaximumDesign

    Capacity

    Materials Units n Units d

    127 Casting Cutting Station 2-5EU 078 Active PER 011 CE 016SV 039 (M) Hr 3321Yasec Yamashino Seik OL 0.35 Ton

    128 Casting Cutting Station 2-5EU 078 Removed PER 012 Hr 3321Yasec Yamashino Seik OL 0.35 Ton

    129 Machining Lathe 2-1EU 079 Active PER 011 CE 015SV 030 (M) Hr 3321Okuma Lathes LU-25 0.3182 Ton

    130 Machining Lathe 2-1 -Machining Equipment

    EU 079 Active PER 012 CE 016SV 039 (M) Hr 3321Okuma Lathes LU-25 0.3182 Ton

    131 Machining Lathe 2-2EU 080 Active PER 011 CE 015SV 030 (M) Hr 3321Okuma Lathes LU-25 0.3182 Ton

    132 Machining Lathe 2-2 -Machining Equipment

    EU 080 Active PER 012 CE 016SV 039 (M) Hr 3321Okuma Lathes LU-25 0.3182 Ton

    133 Machining Lathe 2-3EU 081 Active PER 011 CE 015SV 030 (M) Hr 3321Okuma Lathes LU-25 0.3182 Ton

    134 Machining Lathe 2-3 -Machining Equipment

    EU 081 Active PER 012 CE 016SV 039 (M) Hr 3321Okuma Lathes LU-25 0.3182 Ton

    135 Brushing Unit Machine Line3-1

    EU 082 Active PER 011 CE 016SV 039 (M) Hr 3321Yoshida Unit 3 0.875 Ton

    136 Brushing Unit Machine Line3-1 - Abrasive Equipment

    EU 082 Active PER 012 CE 016SV 039 (M) Hr 3321Yoshida Unit 3 0.875 Ton

    137 Brushing Unit Machine Line4-1

    EU 083 Active PER 011 CE 016SV 039 (M) Hr 3321Yoshida Unit 4 0.875 Ton

    138 Brushing Unit Machine Line4-1 - Abrasive Equipment

    EU 083 Active PER 012 CE 016SV 039 (M) Hr 3321Yoshida Unit 4 0.875 Ton

    139 LIne #2 Casting FinishingStation #6

    EU 084 Removed PER 011 Hr 3321Okuma Lathes LR25 97 Each

    140 Line #2 Casting FinishingStation #7

    EU 085 Removed PER 011 Hr 3321Okuma Lathes LR25 97 Each

    0.5141 Die Heater Burner 2-1EU 086 Active PER 011 SV 036 (M) Hr Heat3321Applied Thermo Techno Custom 0.5 Mmbtu

    0.5142 Die Heater Burner 2-1 -Process Heater

    EU 086 Active PER 012 SV 036 (M) Hr Heat3321Applied Thermo Techno Custom 0.5 Mmbtu

    0.5143 Die Heater Burner 2-2EU 087 Active PER 011 SV 036 (M) Hr Heat3321Applied Thermo Techno Custom 0.5 Mmbtu

    0.5144 Die Heater Burner 2-2 -Process Heater

    EU 087 Active PER 012 SV 036 (M) Hr Heat3321Applied Thermo Techno Custom 0.5 Mmbtu

    0.5145 Die Heater Burner 2-3EU 088 Active PER 011 SV 036 (M) Hr Heat3321Applied Thermo Techno Custom 0.5 Mmbtu

    0.5146 Die Heater Burner 2-3 -Process Heater

    EU 088 Active PER 012 SV 036 (M) Hr Heat3321Applied Thermo Techno Custom 0.5 Mmbtu

    0.25147 Die Heater Burner 2-4EU 089 Removed PER 011 Hr Heat3321Applied Thermo Techno Custom 250000 Btu

    0.25148 Die Heater Burner 2-5EU 090 Removed PER 011 Hr Heat3321Applied Thermo Techno Custom 250000 Btu

    Page 7 of 17 (a)

  • 12 November, 2014 10:02

    FACILITY DESCRIPTION: EMISSION UNIT (EU)

    ID No. ElevatorType

    BottleneckPct.Fuel/

    SpaceHeat

    Firing MethodAddedBy

    (Action)

    RemovalDate

    InitialStartup

    Date

    Comm-ence

    Const.Date

    EmissionUnit

    Status

    127 EU 078 PER 011 12/01/200304/01/2003Active

    128 EU 078 PER 012 12/01/200304/01/2003Removed

    129 EU 079 PER 011 12/01/200304/01/2003Active

    130 EU 079 PER 012 12/01/200304/01/2003Active

    131 EU 080 PER 011 12/01/200304/01/2003Active

    132 EU 080 PER 012 12/01/200304/01/2003Active

    133 EU 081 PER 011 12/01/200304/01/2003Active

    134 EU 081 PER 012 12/01/200304/01/2003Active

    135 EU 082 PER 011 12/01/200304/01/2003Active

    136 EU 082 PER 012 12/01/200304/01/2003Active

    137 EU 083 PER 011 12/01/200304/01/2003Active

    138 EU 083 PER 012 12/01/200304/01/2003Active

    139 EU 084 PER 011 11/30/200712/01/200304/01/2003Removed

    140 EU 085 PER 011 11/30/200712/01/200304/01/2003Removed

    141 EU 086 PER 011 12/01/200304/01/2003Active

    142 EU 086 PER 012 12/01/200304/01/2003Active

    143 EU 087 PER 011 12/01/200304/01/2003Active

    144 EU 087 PER 012 12/01/200304/01/2003Active

    145 EU 088 PER 011 12/01/200304/01/2003Active

    146 EU 088 PER 012 12/01/200304/01/2003Active

    147 EU 089 PER 011 12/01/200304/01/2003Removed

    148 EU 090 PER 011 12/01/200304/01/2003Removed

    Page 7 of 17 (b)

  • ST. PAUL, MN 55155-4194

    Show: Active and Pending RecordsAction: PER 012AQD Facility ID: 15700015Facility Name:

    MINNESOTA POLLUTION CONTROL AGENCYAIR QUALITY520 LAFAYETTE ROAD

    12 November, 2014 10:02

    FACILITY DESCRIPTION: EMISSION UNIT (EU)

    MaxFuelInput

    (mil Btu)

    Federal-Mogul Corp Powertrain Systems

    RetiredBy

    (Action)

    Operator DescriptionID No. EmissionUnit

    Status

    AddedBy

    (Action)

    ControlEquip.

    ID No(s).

    Stack/Vent

    ID No(s).

    OperatorID

    for Item

    Insignif-icant

    Activity

    SICManufacturer ModelNumber

    Max.Design

    Capacity

    MaximumDesign

    Capacity

    Materials Units n Units d

    0.25149 Die Heater Burner 2-6EU 091 Removed PER 011 Hr Heat3321Applied Thermo Techno Custom 250000 Btu

    0.25150 Die Heater Burner 2-7EU 092 Removed PER 011 Hr Heat3321Applied Thermo Techno Custom 250000 Btu

    0.25151 Die Heater Burner 2-8EU 093 Removed PER 011 Hr Heat3321Applied Thermo Techno Custom 250000 Btu

    0.25152 Die Heater Burner 2-9EU 094 Removed PER 011 Hr Heat3321Applied Thermo Techno Custom 250000 Btu

    0.25153 Die Heater Burner 2-10EU 095 Removed PER 011 Hr Heat3321Applied Thermo Techno Custom 250000 Btu

    154 Line #1 Centrifugal Pouring &Cooling

    EU 096 Active PER 011 CE 015SV 030 (M) Hr 3321Duca Custom 1.75 Ton

    155 Line #1 Centrifugal Pouring &Cooling - Pouring Equipment

    EU 096 Active PER 012 CE 015SV 030 (M) Hr 3321Duca Custom 1.75 Ton

    156 Line #2 Centrifugal Pouring &Cooling

    EU 097 Active PER 011 CE 016SV 039 (M) Hr 3321Otani Custom 1.75 Ton

    157 Line #2 Centrifugal Pouring &Cooling - Pouring Equipment

    EU 097 Active PER 012 CE 016SV 039 (M) Hr 3321Otani Custom 1.75 Ton

    158 JV Charge Handling BridgeCrane

    EU 098 Active PER 011 SV 044 (M) Hr 3321Konecranes 10 ton 3.50 Ton

    159 JV Charge Handling BridgeCrane - Material HandlingEquipment

    EU 098 Active PER 012 SV 044 (M) Hr 3321Konecranes 10 ton 3.50 Ton

    160 FM Inductotherm CorelessFurnace #5

    EU 099 Active PER 011 CE 017SV 040 (M) Hr 3321Inductotherm 2000 KW VIP DT-2 2.31 Ton

    161 FM Inductotherm CorelessFurnace #5 - Furnace

    EU 099 Active PER 012 CE 017SV 040 (M) Hr 3321Inductotherm 2000 KW VIP DT-2 2.31 Ton

    162 FM Inductotherm CorelessFurnace #6

    EU 100 Active PER 011 CE 017SV 040 (M) Hr 3321Inductotherm 2000 KW VIP DT-2 2.31 Ton

    163 FM Inductotherm CorelessFurnace #6 - Furnace

    EU 100 Active PER 012 CE 017SV 040 (M) Hr 3321Inductotherm 2000 KW VIP DT-2 2.31 Ton

    164 Line #3 Centrifugal Pouring &Cooling

    EU 101 Active PER 011 CE 019SV 045 (M) Hr 3321ABP Induction Minipour 3.5 3.5 Ton

    165 Line #3 Centrifugal Pouring &Cooling - Pouring Equipment

    EU 101 Active PER 012 CE 019SV 045 (M) Hr 3321ABP Induction Minipour 3.5 3.5 Ton

    166 Air Blowout Gun Line 3EU 102 Active PER 011 CE 019SV 045 (M) Hr 3321Guardair 75XT 64.68 Lb

    167 Air Blowout Gun Line 3 -Blowing Equipment

    EU 102 Active PER 012 CE 019SV 045 (M) Hr 3321Guardair 75XT 64.68 Lb

    168 Coating Application Wand Line3

    EU 103 Active PER 011 CE 019SV 045 (M) Hr 3321Federal-Mogul 70140200 64.68 Lb

    Page 8 of 17 (a)

  • 12 November, 2014 10:02

    FACILITY DESCRIPTION: EMISSION UNIT (EU)

    ID No. ElevatorType

    BottleneckPct.Fuel/

    SpaceHeat

    Firing MethodAddedBy

    (Action)

    RemovalDate

    InitialStartup

    Date

    Comm-ence

    Const.Date

    EmissionUnit

    Status

    149 EU 091 PER 011 12/01/200304/01/2003Removed

    150 EU 092 PER 011 12/01/200304/01/2003Removed

    151 EU 093 PER 011 12/01/200304/01/2003Removed

    152 EU 094 PER 011 12/01/200304/01/2003Removed

    153 EU 095 PER 011 12/01/200304/01/2003Removed

    154 EU 096 PER 011 12/01/200304/01/2003Active

    155 EU 096 PER 012 12/01/200304/01/2003Active

    156 EU 097 PER 011 12/01/200304/01/2003Active

    157 EU 097 PER 012 12/01/200304/01/2003Active

    158 EU 098 PER 011 12/01/200304/01/2003Active

    159 EU 098 PER 012 12/01/200304/01/2003Active

    160 EU 099 PER 011 12/01/200304/01/2003Active

    161 EU 099 PER 012 12/01/200304/01/2003Active

    162 EU 100 PER 011 12/01/200304/01/2003Active

    163 EU 100 PER 012 12/01/200304/01/2003Active

    164 EU 101 PER 011 09/01/200601/01/2006Active

    165 EU 101 PER 012 09/01/200601/01/2006Active

    166 EU 102 PER 011 10/01/200601/01/2005Active

    167 EU 102 PER 012 10/01/200601/01/2005Active

    168 EU 103 PER 011 10/01/200601/01/2005Active

    Page 8 of 17 (b)

  • ST. PAUL, MN 55155-4194

    Show: Active and Pending RecordsAction: PER 012AQD Facility ID: 15700015Facility Name:

    MINNESOTA POLLUTION CONTROL AGENCYAIR QUALITY520 LAFAYETTE ROAD

    12 November, 2014 10:02

    FACILITY DESCRIPTION: EMISSION UNIT (EU)

    MaxFuelInput

    (mil Btu)

    Federal-Mogul Corp Powertrain Systems

    RetiredBy

    (Action)

    Operator DescriptionID No. EmissionUnit

    Status

    AddedBy

    (Action)

    ControlEquip.

    ID No(s).

    Stack/Vent

    ID No(s).

    OperatorID

    for Item

    Insignif-icant

    Activity

    SICManufacturer ModelNumber

    Max.Design

    Capacity

    MaximumDesign

    Capacity

    Materials Units n Units d

    169 Coating Application Wand Line3 - Spray Booth/Coating Line

    EU 103 Active PER 012 CE 019SV 045 (M) Hr 3321Federal-Mogul 70140200 64.68 Lb

    170 Line #3 Abrasive Blasting Unit#1 Long Tube

    EU 104 Active PER 011 CE 019SV 045 (M) Hr 3321US Filter/Wheelabrator 6 3.5 Ton

    171 Line #3 Abrasive Blasting Unit#1 Long Tube - AbrasiveEquipment

    EU 104 Active PER 012 CE 019SV 045 (M) Hr 3321US Filter/Wheelabrator 6 3.5 Ton

    172 Line #3 Abrasive Blasting Unit#2

    EU 105 Removed PER 011 Hr 3321US Filter/Wheelabrator 7 338 Each

    173 Line #3 Abrasive Blasting Unit#3

    EU 106 Removed PER 011 Hr 3321US Filter/Wheelabrator 7 338 Each

    174 Casting Cutting Station 3-1EU 107 Active PER 011 CE 019SV 045 (M) Hr 3321Yasec Yamashino Seik OL 0.7 Ton

    175 Casting Cutting Station 3-1 -Casting Equipment

    EU 107 Active PER 012 CE 019SV 045 (M) Hr 3321Yasec Yamashino Seik OL 0.7 Ton

    176 Casting Cutting Station 3-2EU 108 Active PER 011 CE 019SV 045 (M) Hr 3321Yasec Yamashino Seik OL 0.7 Ton

    177 Casting Cutting Station 3-2 -Casting Equipment

    EU 108 Active PER 012 CE 019SV 045 (M) Hr 3321Yasec Yamashino Seik OL 0.7 Ton

    178 Casting Cutting Station 3-3EU 109 Active PER 011 CE 019SV 045 (M) Hr 3321Yasec Yamashino Seik OL 0.7 Ton

    179 Casting Cutting Station 3-3 -Casting Equipment

    EU 109 Active PER 012 CE 019SV 045 (M) Hr 3321Yasec Yamashino Seik OL 0.7 Ton

    180 Casting Cutting Station 3-4EU 110 Active PER 011 CE 019SV 045 (M) Hr 3321Yasec Yamashino Seik OL 0.7 Ton

    181 Casting Cutting Station 3-4 -Casting Equipment

    EU 110 Active PER 012 CE 019SV 045 (M) Hr 3321Yasec Yamashino Seik OL 0.7 Ton

    182 Casting Cutting Station 3-5EU 111 Active PER 011 CE 019SV 045 (M) Hr 3321Yasec Yamashino Seik OL 0.7 Ton

    183 Casting Cutting Station 3-5 -Casting Equipment

    EU 111 Active PER 012 CE 019SV 045 (M) Hr 3321Yasec Yamashino Seik OL 0.7 Ton

    184 Machining Lathe 5-1EU 112 Active PER 011 CE 019SV 045 (M) Hr 3321Okuma LU-400 0.3182 Ton

    185 Machining Lathe 5-1 -Machining Equipment

    EU 112 Active PER 012 CE 019SV 045 (M) Hr 3321Okuma LU-400 0.3182 Ton

    186 Machining Lathe 5-2EU 113 Active PER 011 CE 019SV 045 (M) Hr 3321Okuma LU-400 0.3182 Ton

    187 Machining Lathe 5-2 -Machining Equipment

    EU 113 Active PER 012 CE 019SV 045 (M) Hr 3321Okuma LU-400 0.3182 Ton

    188 Machining Lathe 5-3EU 114 Active PER 011 CE 019SV 045 (M) Hr 3321Okuma LU-400 0.3182 Ton

    189 Machining Lathe 5-3 -Machining Equipment

    EU 114 Active PER 012 CE 019SV 045 (M) Hr 3321Okuma LU-400 0.3182 Ton

    Page 9 of 17 (a)

  • 12 November, 2014 10:02

    FACILITY DESCRIPTION: EMISSION UNIT (EU)

    ID No. ElevatorType

    BottleneckPct.Fuel/

    SpaceHeat

    Firing MethodAddedBy

    (Action)

    RemovalDate

    InitialStartup

    Date

    Comm-ence

    Const.Date

    EmissionUnit

    Status

    169 EU 103 PER 012 10/01/200601/01/2005Active

    170 EU 104 PER 011 10/01/200601/01/2005Active

    171 EU 104 PER 012 10/01/200601/01/2005Active

    172 EU 105 PER 011 11/30/200710/01/200601/01/2005Removed

    173 EU 106 PER 011 11/30/200710/01/200601/01/2005Removed

    174 EU 107 PER 011 09/01/200601/01/2006Active

    175 EU 107 PER 012 09/01/200601/01/2006Active

    176 EU 108 PER 011 09/01/200601/01/2006Active

    177 EU 108 PER 012 09/01/200601/01/2006Active

    178 EU 109 PER 011 09/01/200601/01/2006Active

    179 EU 109 PER 012 09/01/200601/01/2006Active

    180 EU 110 PER 011 09/01/200601/01/2006Active

    181 EU 110 PER 012 09/01/200601/01/2006Active

    182 EU 111 PER 011 09/01/200601/01/2006Active

    183 EU 111 PER 012 09/01/200601/01/2006Active

    184 EU 112 PER 011 09/01/200601/01/2006Active

    185 EU 112 PER 012 09/01/200601/01/2006Active

    186 EU 113 PER 011 09/01/200601/01/2006Active

    187 EU 113 PER 012 09/01/200601/01/2006Active

    188 EU 114 PER 011 09/01/200601/01/2006Active

    189 EU 114 PER 012 09/01/200601/01/2006Active

    Page 9 of 17 (b)

  • ST. PAUL, MN 55155-4194

    Show: Active and Pending RecordsAction: PER 012AQD Facility ID: 15700015Facility Name:

    MINNESOTA POLLUTION CONTROL AGENCYAIR QUALITY520 LAFAYETTE ROAD

    12 November, 2014 10:02

    FACILITY DESCRIPTION: EMISSION UNIT (EU)

    MaxFuelInput

    (mil Btu)

    Federal-Mogul Corp Powertrain Systems

    RetiredBy

    (Action)

    Operator DescriptionID No. EmissionUnit

    Status

    AddedBy

    (Action)

    ControlEquip.

    ID No(s).

    Stack/Vent

    ID No(s).

    OperatorID

    for Item

    Insignif-icant

    Activity

    SICManufacturer ModelNumber

    Max.Design

    Capacity

    MaximumDesign

    Capacity

    Materials Units n Units d

    190 Machining Lathe 5-4EU 115 Active PER 011 CE 019SV 045 (M) Hr 3321Okuma LU-400 0.3182 Ton

    191 Machining Lathe 5-4 -Machining Equipment

    EU 115 Active PER 012 CE 019SV 045 (M) Hr 3321Okuma LU-400 0.3182 Ton

    192 Machining Lathe 6-1EU 116 Active PER 011 CE 019SV 045 (M) Hr 3321Okuma LU-400 0.3182 Ton

    193 Machining Lathe 6-1 -Machining Equipment

    EU 116 Active PER 012 CE 019SV 045 (M) Hr 3321Okuma LU-400 0.3182 Ton

    194 Machining Lathe 6-2EU 117 Active PER 011 CE 019SV 045 (M) Hr 3321Okuma LU-400 0.3182 Ton

    195 Machining Lathe 6-2 -Machining Equipment

    EU 117 Active PER 012 CE 019SV 045 (M) Hr 3321Okuma LU-400 0.3182 Ton

    196 Machining Lathe 6-3EU 118 Active PER 011 CE 019SV 045 (M) Hr 3321Okuma LU-400 0.3182 Ton

    197 Machining Lathe 6-3 -Machining Equipment

    EU 118 Active PER 012 CE 019SV 045 (M) Hr 3321Okuma LU-400 0.3182 Ton

    0.595248198 Die Heater Burner 3-1EU 119 Active PER 011 SV 043 (M) Hr Heat3321Yamashino Seiki Co. LT OP-8 595248 Btu

    0.595248199 Die Heater Burner 3-1 -Process Heater

    EU 119 Active PER 012 SV 043 (M) Hr Heat3321Yamashino Seiki Co. LT OP-8 595248 Btu

    0.595248200 Die Heater Burner 3-2EU 120 Active PER 011 SV 043 (M) Hr Heat3321Yamashino Seiki Co. LT OP-8 595248 Btu

    0.595248201 Die Heater Burner 3-2 -Process Heater

    EU 120 Active PER 012 SV 043 (M) Hr Heat3321Yamashino Seiki Co. LT OP-8 595248 Btu

    0.595248202 Die Heater Burner 3-3EU 121 Active PER 011 SV 043 (M) Hr Heat3321Yamashino Seiki Co. LT OP-8 595248 Btu

    0.595248203 Die Heater Burner 3-3 -Process Heater

    EU 121 Active PER 012 SV 043 (M) Hr Heat3321Yamashino Seiki Co. LT OP-8 595248 Btu

    .25204 Die Heater Burner 3-4EU 122 Removed PER 011 Hr Heat3321Yamashino Seiki Co. LT OP-8 .25 Mmbtu

    .25205 Die Heater Burner 3-5EU 123 Removed PER 011 Hr Heat3321Yamashino Seiki Co. LT OP-8 .25 Mmbtu

    .25206 Die Heater Burner 3-6EU 124 Removed PER 011 Hr Heat3321Yamashino Seiki Co. LT OP-8 .25 Mmbtu

    .25207 Die Heater Burner 3-7EU 125 Removed PER 011 Hr Heat3321Yamashino Seiki Co. LT OP-8 .25 Mmbtu

    .25208 Die Heater Burner 3-8EU 126 Removed PER 011 Hr Heat3321Yamashino Seiki Co. LT OP-8 .25 Mmbtu

    .25209 Die Heater Burner 3-9EU 127 Removed PER 011 Hr Heat3321Yamashino Seiki Co. LT OP-8 .25 Mmbtu

    .25210 Die Heater Burner 3-10EU 128 Removed PER 011 Hr Heat3321Yamashino Seiki Co. LT OP-8 .25 Mmbtu

    211 Shotblast Cleaning of Castings#2

    EU 129 Active PER 011 CE 002SV 004 (M) Hr 3321wheelabrator 28 cubic feet 2.92 Ton

    212 Shotblast Cleaning of Castings#2 - Abrasive Equipment

    EU 129 Active PER 012 CE 002SV 004 (M) Hr 3321wheelabrator 28 cubic feet 2.92 Ton

    Page 10 of 17 (a)

  • 12 November, 2014 10:02

    FACILITY DESCRIPTION: EMISSION UNIT (EU)

    ID No. ElevatorType

    BottleneckPct.Fuel/

    SpaceHeat

    Firing MethodAddedBy

    (Action)

    RemovalDate

    InitialStartup

    Date

    Comm-ence

    Const.Date

    EmissionUnit

    Status

    190 EU 115 PER 011 09/01/200601/01/2006Active

    191 EU 115 PER 012 09/01/200601/01/2006Active

    192 EU 116 PER 011 09/01/200601/01/2006Active

    193 EU 116 PER 012 09/01/200601/01/2006Active

    194 EU 117 PER 011 09/01/200601/01/2006Active

    195 EU 117 PER 012 09/01/200601/01/2006Active

    196 EU 118 PER 011 09/01/200601/01/2006Active

    197 EU 118 PER 012 09/01/200601/01/2006Active

    198 EU 119 PER 011 10/01/200601/01/2005Active

    199 EU 119 PER 012 10/01/200601/01/2005Active

    200 EU 120 PER 011 10/01/200601/01/2005Active

    201 EU 120 PER 012 10/01/200601/01/2005Active

    202 EU 121 PER 011 10/01/200601/01/2005Active

    203 EU 121 PER 012 10/01/200601/01/2005Active

    204 EU 122 PER 011 10/01/200601/01/2005Removed

    205 EU 123 PER 011 10/01/200601/01/2005Removed

    206 EU 124 PER 011 10/01/200601/01/2005Removed

    207 EU 125 PER 011 10/01/200601/01/2005Removed

    208 EU 126 PER 011 10/01/200601/01/2005Removed

    209 EU 127 PER 011 10/01/200601/01/2005Removed

    210 EU 128 PER 011 10/01/200601/01/2005Removed

    211 EU 129 PER 011 01/31/200001/01/2000Active

    212 EU 129 PER 012 01/31/200001/01/2000Active

    Page 10 of 17 (b)

  • ST. PAUL, MN 55155-4194

    Show: Active and Pending RecordsAction: PER 012AQD Facility ID: 15700015Facility Name:

    MINNESOTA POLLUTION CONTROL AGENCYAIR QUALITY520 LAFAYETTE ROAD

    12 November, 2014 10:02

    FACILITY DESCRIPTION: EMISSION UNIT (EU)

    MaxFuelInput

    (mil Btu)

    Federal-Mogul Corp Powertrain Systems

    RetiredBy

    (Action)

    Operator DescriptionID No. EmissionUnit

    Status

    AddedBy

    (Action)

    ControlEquip.

    ID No(s).

    Stack/Vent

    ID No(s).

    OperatorID

    for Item

    Insignif-icant

    Activity

    SICManufacturer ModelNumber

    Max.Design

    Capacity

    MaximumDesign

    Capacity

    Materials Units n Units d

    213 Shotblast Cleaning of Castings#3

    EU 130 Active PER 011 CE 002SV 004 (M) Hr 3321wheelabrator 28 cubic feet 2.92 Ton

    214 Shotblast Cleaning of Castings#3 - Abrasive Equipment

    EU 130 Active PER 012 CE 002SV 004 (M) Hr 3321wheelabrator 28 cubic feet 2.92 Ton

    215 Line #3 Charge Handling &Conveyor

    EU 131 Active PER 011 SV 044 (M) Hr 3321Kinergy Corp KDF-30/48-EHD 3.5 Ton

    216 Line #3 Charge Handling &Conveyor - Conveyor

    EU 131 Active PE