tecnologia aclara
DESCRIPTION
Aclara integra tecnologías AMI de vanguardia comprobadamente eficaces en la captura, análisis y aplicación de la información requerida por las empresas de servicios públicos, a fin de satisfacer sus necesidades actuales y futuras.TRANSCRIPT
The NCC database stores meter readings from the system data
collectors. The data is displayed through a series of five tabs,
creating a simple roadmap through the software and providing
a variety of search and reporting options.
The STAR Network NCC allows utilities tobetter manage information about customeraccounts, meter transmitters, and datacollectors. What’s more, itmakes it easytotransfer gas, water, and electric meter data tobilling, customer service, accounting, andother utility applications.
www.Aclara.comCapturing data. Liberating knowledge.™
STAR® Network NCCNETWORK CONTROL COMPUTER
The STAR Network NCC delivers
Record processingSynchronizes records established byhand-held field programmers with the NCC
Alarm notificationSends a message when an alarm is insertedin the database
Data captureMaintains account number, meter type,meter transmission unit ID, meter serialnumber, and alarm parameters for all utilitymeters
Demand responseSupports demand parameters and intervalreads for electric meters
Capturing data. Liberating knowledge.™
As the system’s central computer system, the network control computer (NCC) collects,validates, processes, stores, and regularly transmits meter readings gathered from thesystem’s meter transmission units (MTUs) and data collector units (DCUs) over FCC-licensed, 450- to 470-MHz radio frequencies. The NCC provides billing, customer service,accounting, and other utility departments with access to valuable account information.
STAR® Network NCC
Customize this tab name to match internalnaming conventions
Search detailed MTU data on an individualunit or account basis
Run reports on MTU readings, consumption,transmission records, maintenance, anddiagnostics
Manage MTU Data
Search individual unit or system DCU databy date range
Edit DCU information
Run DCU system reports on calls, RSSi,diagnostics, and battery voltage
Run individual DCU reports on calls, RSSi,diagnostic messages, battery voltage, andtemperature
Manage DCU Data
www.Aclara.com
Track MTU installations and fieldprogrammer records
Search database by MTU, account ID, installer,programmer, or keyword
Run reports on installs, programmer records,missing records, and missing wake-up signals
Create or edit wake-up and programmerrecords with the appropriate access rights
Track MTU Installations
View existing reports or configure newones for a selected date range
Monitor MTUs in logical groups or byindividual account number
Edit report groups by criteria oraccount number
Create and View Reports
Configure and manage system settings
Define user roles, utilities, alarms, meters,and archiving parameters
Open to only those with appropriateaccess rights
Configure System Settings
Aclara23905 Mercantile Road, Beachwood, OH 44122 | P: 800.969.1057 | F: [email protected] | www.Aclara.com
09/08©2008 Aclara. All rights reserved. STAR® Network is a registered trademark of Aclara RF Systems Inc.
The STAR Network NCC allows utilities to better manage information about customer accounts, meter transmitters, and data collectors.
For more information on the STAR ® Network system and the benefits of powerful AMI/AMR,visit our website at www.Aclara.com.
Gas
SCADA, IVR,
OMS, GIS, CIS, or
other applications
Client
workstations
ElectricWater
• Application server
• Database server
Network ControlComputer
STAR® Network NCCSystem Diagram
Data CollectorUnit II
MeterTransmission
Units
Our proven, wide-area network (WAN) backhaul options
support data-intense applications such as real-time pricing,
demand response, remote leak detection, and always-on
connections to the utility.
Each STAR Network DCU II delivers
Reliable technologyCommunicates with FCC-licensed, narrow-band transceivers
Safety and securityInitiates an immediate message transfer upon receipt of an event or alarm from an MTU
Robust operationDelivers Part 90 radio technology to transmit commands to MTUs.
Rugged, weatherproof designMounts on buildings, utility poles, or towers
WAN compatibilityCommunicates over cellular, fiber-optic, Ethernet, Wi-Fi, and WiMAX networks
FCC complianceMeets requirements under Part 15 and Part 90 for a Class A digital device
Backwards compatibilityReplaces older style models of the DCU
The STAR Network DCU II enhances yourAMI network by providing reliable andflexible two-way communication for electric,water, and gas meters.
STAR® Network DCU IIDATA COLLECTOR UNIT
www.AclaraTech.comCapturing data. Liberating knowledge.™
The DCU II transmits and receives
data over individual 450- to 470-MHz
radio frequencies. Powered by a
battery that can be recharged by a
solar panel or AC power supply, the
DCU time stamps, processes, and
stores diagnostic information and
data collected from meter transmission
units (MTUs). The DCU transmits the
data for further processing to the
utility's network control computer
(NCC) and sends commands and
alerts back to the MTUs.
Data Collector Unit (DCU) II
SCADA, IVR,
OMS, GIS, CIS, or
other applications
STAR Network DCU IISystem Diagram
Gas MTU
STAR® Network DCU II
Client
workstations
The STAR Network DCU II collects meter reading data from STAR Network meter transmission units (MTUs) and transfers it to the NCC,providing the benefits of valuable AMI/AMR.
Aclara23905 Mercantile Road, Beachwood, OH 44122 | P: 800.969.1057 | F: [email protected] | www.AclaraTech.com
05/08©2008 Aclara. All rights reserved. STAR Network is a registered trademark of Aclara RF Systems Inc.
Network ControlComputer (NCC)
• Application server• Database server
Electric MTU
Water MTU
Create Your Intelligent Infrastructure™
METER TRANSMISSION UNIT3300 Water MTU
3321-012-RB
3322-012-RB
3321-012-DB
3322-012-DB
3321-012-RBW
3322-012-RBW
3321-012-DBW
3322-012-DBW
ModelsPulse, single-port MTU
Pulse, dual-port MTU
Encoder, single-port MTU
Encoder, dual-port MTU
Pulse, single-port MTU with extended range
Pulse, dual-port MTU with extended range
Encoder, single-port MTU with extended range
Encoder, dual-port MTU with extended range
STAR® Network
3000 Series
Delivers two-way communication •
Captures hourly meter data •
Provides system-wide •time synchronization
Supports up to 8-digit registers •
Maintains a 20-year permanent battery •
Operates over FCC-licensed •radio frequencies
Delivers two-way communication and a time-synchronized network to provide a utility with a snapshot of system water consumption at a single point in time.
The 3300 water MTU uses the powerful STAR Network RF technology to transmit hourly, interval usage data, and two-way communication to the utility. The MTU supports up to 8-digit registers and delivers time-stamped reads on a time-synchronized network, allowing for advanced water distribution management.
Time Synchronization
The 3300 water MTU features time synchronization to ensure that all system clocks are set to the same time. This allows a utility to take a complete system read and use the data to reconcile the amount of water entering the system to the billable water that is consumed, thus identifying the probability of system leaks.
Aclara30400 Solon Road, Solon, Ohio 44139 | P: 800.969.1057 | F: [email protected] | www.Aclara.com
©2010 Aclara. All rights reserved. STAR is a registered trademark of Aclara RF Systems Inc.329-R1
STAR® Network 3300 Water MTU
Standard System ReportsDuplicate meter serial number request•Duplicate MTUs report•Reception report•Tamper report•Total consumption•Zero consumption•Missing reads•MTU:DCU redundancy•
Notes:1: Two-way communication for time synchronization and time management2: Pit/vault installation under non-metallic lid3: Battery life is stated at default settings4: Standard range5: Refer to Aclara standard warranty for details6: Reports all digits that are electronically available from register7: Pulse input only
Specifications are subject to change without notice.
Hourly Reads
The 3300 water MTU delivers hourly, time-stamped reads, providing detailed information about water usage and identifying anomalies such as potential leaks and meter tampering.
Network type
Transmit/receive frequency
Antenna
Installation locations
Read interval
Transmit interval
Inputs
Wire length
Battery life
End point to end point time difference
Physical characteristics
Weight
Color
Operating temp range
Operating humidity
Transmit power options
Approvals
Warranty
Meter compatibility
Network topology
Network compatibility
Handheld interface
Meter interface
Data resolution
Maximum meter pulse frequency
Two-way1
450-470 MHz (FCC licensed)
Internal
Interior wall mount, exterior wall mount, pit/vault2
Hourly–top of the hour readings default
Four times per day default
Single or dual
12 feet-22 AWG solid wire
20 years3,4
< 1 min
6.38” W x 4.25” H x 1.44” D
1 lb
Gray
-30ºC to +70ºC
0% - 100% condensing
Standard and extended range available
FCC part 90 : Industry Canada RSS-119
20 years5
All major manufactures of water meters
STAR Network
Aclara DCU IIJ
Windows Mobile handheld
Pulse or encoder
4-8 digits6
Three pulses per second7
Specifications
System Data Support
The STAR Network system provides full data support from the meter to your utility office. The system’s Network Control Computer (NCC) manages and searches MTU data, tracks MTU installations, configures system settings and user roles, and creates reports to monitor MTUs in logical groups or by individual accounts.
Create Your Intelligent Infrastructure™ www.Aclara.com
STAR® Network 4000 Series
Pinpoint accuracyIdentify precise leak locations with correlated, time-synchronized sound recordings.
Hands-off operationPerform automated data collection with minimal attention by operators.
Added valueAdd leak detection easily to two-way STAR Network AMI systems.
Installation flexibilityImplement permanent or “lift and shift” deployment.
ConservationEnhance efforts by containing leaks and water loss.
Built for extreme conditionsEnvironmentally sealed MTU prevents damage caused by water or snow.
Material compatibilityWorks on pipes made of a range of materials including metal, concrete and non-metallic types.
STAR ZoneScan system benefits
STAR® ZoneScanCORRELATED ACOUSTIC LEAK DETECTION SYSTEM
Find and fix leaks fast with the Aclara STAR ZoneScan leak-detection system. The industry’s only remotely correlated acoustic leak-detection system cost-effectively identifies small leaks before they become major problems.The system combines acoustic data loggers from Gutermann International with Aclara STAR Network technology to provide fully integrated leak detection through fixed-network advanced metering infrastructure (AMI). Time-synchronized sound recordings are initiated through the STAR ZoneScan meter transmission unit (MTU), which sends the resulting data back through fixed-network infrastructure to the utility for presentation. Web-based application software correlates the data between loggers and provides visual identification of high probability leak locations.
327-R4 12/11
Aclara945 Hornet Drive, Hazelwood, MO 63042 | P: 800.297.2728 | F: [email protected] | www.Aclara.com
©2011 Aclara. All rights reserved. Aclara and STAR are registered trademarks of Aclara.All other trademarks belong to their respective owners.
STAR® ZoneScan
SpecificationsNetwork Type Two-way1 STAR Network
Transmit/receive frequency 450-470 MHz, FCC licensed2
Antenna Internal
Cable length Six feet with watertight connector
Amplitude measurement duration Two hours (default)
Correlation recording duration One 12-second recording (default)
Data transmission Once per day
MTU battery life Five years3
Physical dimensions MTU diameter 5-1/8 inch; Lid diameter 7-1/4 inch
Operating temp range -30°C to +70°C
Operating humidity 0- 100 percent condensing
Transmit power 0.25 W
Approvals FCC part 90
Network compatibility Aclara DCU IIJ/NCC v7.3.4 or higher with STAR ZoneScan software module
Handheld interface Windows Mobile handheld
Notes:1: Two-way communication is required for time synchronization.2: A dedicated frequency is recommended for STAR ZoneScan.3: MTU battery life is stated at default settings. Refer to STAR ZoneScan MTU warranty for details. Specifications are subject to change without notice.
System Components The STAR ZoneScan leak-detection system includes:
• Gutermann model 820 acoustic logger with watertight connector cable
• Circular, 7-1/4” diameter non-metallic lid • STAR ZoneScan software module• Gutermann software license
CONFIDENTIAL INTERNAL COMMUNICATIONS – DO NOT DISTRIBUTE
Our customers have asked for it...and we are delivering.Introducing Aclara™ STAR® Network Water and Gas MTUs with Two-Way Communication
Aclara is preparing to launch a family of MTUs that moves beyond meter reading efficiency and provides the two-way communications needed for advanced distribution system management. This new generation of water and gas MTUs is part of the Aclara Intelligent Infrastucture™ platform to help our customers meet their needs and and improve our internal processes for ordering and manufacturing the products.
Over the next year Aclara will release several versions of the MTU with varying and increasing features and pricepoints to meet the requirements of specific applications. This document is designed to educate you on the new Aclara products and their uses. As we approach specific launch dates, and as new materials are created, you will receive additional emails or documents with more information.
Click on any of the buttons below to learn more about our water and gas product lines:
MTU Series Descriptionand Compatibility
Ordering Information Upcoming Product Materials
Two-Way Communicationsand Time Synchronization
Introducing Aclara STAR Network Water and Gas MTUs with Two-Way Communication
Confidential Internal Communications
BACK TO PAGE 1Two-Way Communications and Time Synchronization
The Series 3000 and Series 4000 MTUs introduce two-way communication to the Aclara STAR Networks for gas and water utilities. This creates a new level of data and support we can provide our customers.
While two-way communication and its features are generally understood for most electric networks…all utilities are not created alike. Two-way communication brings different requirements for the gas and water industries.
Electric Network Two-Way
Communication
Series 3000 Series 4000
On-demand reads•Meter configuration•Demand response•Downloadable •firmwareHome area •networking
System time synchronization •for accurate, on-the-hour readings from every endpointTime-stamped reads• System reconciliation to •verify resource output compared to input
System time synchronization •for accurate, on-the-hour readings from every endpointTime-stamped reads•System reconciliation to •verify resource output compared to inputDownloadable firmware•On-demand reads (this will •affect battery life)
Introducing Aclara STAR Network Water and Gas MTUs with Two-Way Communication
Confidential Internal Communications
BACK TO PAGE 1MTU Series Description and Compatibility
Description
This is our current series of water and gas MTUs. All legacy MTU styles and part numbers (501-8150 and 501-7712) will remain the same.
One-way communcation MTUs using the new radio technology and the DCU2 with the J board for increased bandwidth.
Existing customers cannot interchange the higher series MTUs without upgrading to the DCU2 with the J board.
This is a good choice for new customers who only need one-way communication and the ability for hourly reads.
This series provides basic two-way communication to the MTU. Primarily used for system time synchronization, the two-way communciation will ensure that all units on the network are time set within 30 seconds of each other. This synchronized time then allows for accurate, time-stamped readings and system reconciliation to compare resource input to output.
This series provides on-demand, two-way communication. The utility can request and receive an immediate read from the MTU.The Series 3000 and Series 4000 MTUs will be able to co-exist on the STAR Network, giving users the flexibility to decide which endpoint and which features are required for individual locations. Series 4000 water and gas MTUs are planned for release in FY11 Q2.
Features & Benefits
One-way communication•Legacy AMR support•
Increased bandwidth•One-way communication•Hourly reads•Extended range version available•
Increased bandwidth•Basic two-way communication•Hourly reads•Extended range version available•Time synchronization•Time-stamped reads•
Increased bandwidth•On-demand reads •Hourly reads•Extended range version available•Time synchronization•Time-stamped reads•Downloadable firmware•
Compatability
All existing STAR NetworksDCU, DCU2, DCU2J•NCC software 5x, 6x, or 7x•
DCU2J•NCC software 7.3.1•
DCU2J•NCC software 7.3.1•
Works in conjuntion with 3000 •Series MTU networksDCU2J•NCC software 7.3.1•
One-
Way
Com
mun
icat
ion
Two-
Way
Com
mun
icat
ion
Serie
s 50
1Se
ries
2000
Serie
s 30
00Se
ries
4000
Introducing Aclara STAR Network Water and Gas MTUs with Two-Way Communication
Confidential Internal Communications
BACK TO PAGE 1Ordering Information
Continued on Next Page »
Part Numbers and Availability
Model Number Description Series
2321-012-DBW MTU,1-WAY,ENCDR,1P,EXT RNG,HRR Series 2000 Water
3322-012-RB MTU,2-WAY,PULSE,2P,STD RNG,HRR Series 3000 Water
3321-012-RB MTU,2-WAY,PULSE,1P,STD RNG,HRR Series 3000 Water
3321-012-DBW MTU,2-WAY,ENCDR,1P,EXT RNG,HRR Series 3000 Water
3322-012-DBW MTU,2-WAY,ENCDR,2P,EXT RNG,HRR Series 3000 Water
2321-012-RBW MTU,1-WAY,PULSE,1P,EXT RNG,HRR Series 2000 Water
3321-012-RBW MTU,2-WAY,PULSE,1P,EXT RNG,HRR Series 3000 Water
3322-012-RBW MTU,2-WAY,PULSE,2P,EXT RNG,HRR Series 3000 Water
3321-012-DB MTU,2-WAY,ENCDR,1P,STD RNG,HRR Series 3000 Water
3322-012-DB MTU,2-WAY,ENCDR,2P,STD RNG,HRR Series 3000 Water
3321-112-RBW MTU,2-WAY,PULSE,1P,EXT RNG,HRR Series 3000 Water
3321-005-RBW MTU,2-WAY,PULSE,1p,EXT RNG,HRR Series 3000 Water
3221-000-RBS MTU,2-WAY,WIRE,PLS,STD RNG,HRR Series 3000 Gas
3222-000-RBS MTU,2-WAY,WIRE,PLS,STD RNG,HRR Series 3000 Gas
3221-000-RBSW MTU,2-WAY,WIRE,PLS,EXT RNG,HRR Series 3000 Gas
3222-000-RBSW MTU,2-WAY,WIRE,PLS,EXT RNG,HRR Series 3000 Gas
3221-011-RBS MTU,2-WAY,AMER,RES,STD RNG,HRR Series 3000 Gas
3221-021-RBS MTU,2-WAY,RO11,RES,STD RNG,HRR Series 3000 Gas
Curr
ently
Avai
labl
ePl
anne
d fo
r FY1
0 Q
2Pl
anne
d fo
rFY
10 Q
1
The following lists the upcoming Series 2000 and Series 3000 MTUs to be released in the near future.
Introducing Aclara STAR Network Water and Gas MTUs with Two-Way Communication
Confidential Internal Communications
BACK TO PAGE 1
Part Numbers and Availability (Continued)
Ordering Information
Model Number Description Series
3221-031-RBS MTU,2-WAY,SPRG,RES,STD RNG,HRR Series 3000 Gas
3221-015-RBS MTU,2-WAY,AMER,COM,STD RNG,HRR Series 3000 Gas
3221-025-RBS MTU,2-WAY,ROCK,COM,STD RNG,HRR Series 3000 Gas
3221-035-RBS MTU,2-WAY,SPRG,COM,STD RNG,HRR Series 3000 Gas
3221-055-RBS MTU,2-WAY,DRSR,COM,STD RNG,HRR Series 3000 Gas
3221-065-RBS MTU,2-WAY,ROMT,COM,STD RNG,HRR Series 3000 Gas
3221-019-RBS MTU,2-WAY,AMER,CRB,STD RNG,HRR Series 3000 Gas
3221-039-RBS MTU,2-WAY,SPRG,CRB,STD RNG,HRR Series 3000 Gas
3221-059-RBS MTU,2-WAY,DRSR,CRB,STD RNG,HRR Series 3000 Gas
3221-011-RBSW MTU,2-WAY,AMER,RES,EXT RNG,HRR Series 3000 Gas
3221-021-RBSW MTU,2-WAY,RO11,RES,EXT RNG,HRR Series 3000 Gas
3221-031-RBSW MTU,2-WAY,SPRG,RES,EXT RNG,HRR Series 3000 Gas
3221-015-RBSW MTU,2-WAY,AMER,COM,EXT RNG,HRR Series 3000 Gas
3221-025-RBSW MTU,2-WAY,ROCK,COM,EXT RNG,HRR Series 3000 Gas
3221-035-RBSW MTU,2-WAY,SPRG,COM,EXT RNG,HRR Series 3000 Gas
3221-055-RBSW MTU,2-WAY,DRSR,COM,EXT RNG,HRR Series 3000 Gas
3221-065-RBSW MTU,2-WAY,ROMT,COM,EXT RNG,HRR Series 3000 Gas
3221-019-RBSW MTU,2-WAY,AMER,CRB,EXT RNG,HRR Series 3000 Gas
3221-039-RBSW MTU,2-WAY,SPRG,CRB,EXT RNG,HRR Series 3000 Gas
3221-059-RBSW MTU,2-WAY,DRSR,CRB,EXT RNG,HRR Series 3000 Gas
Plan
ned
for F
Y10
Q2/
Q3
Introducing Aclara STAR Network Water and Gas MTUs with Two-Way Communication
Confidential Internal Communications
BACK TO PAGE 1Ordering Information
Series MTU Part Numbering System
XXXX-XXX-XXXX
MTU style CustomizationRadio Behavior
(added as appropriate, all four slots do not have to be filled)
Part numbers will only be created by the engineering department as new MTUs are released.The following pages contain water and gas part number configuration keys and examples to help you understand how to read the numbering system.
Series MTU Part Numbering SystemWater Models
Series MTU Part Numbering SystemGas Models
All series MTUs will use a new consistent numbering system to identify the style and features of the MTU.Water and gas MTUs do have unique markers but all MTU part numbers will follow this basic format.
Introducing Aclara STAR Network Water and Gas MTUs with Two-Way Communication
Confidential Internal Communications
BACK TO PAGE 1Ordering Information
MTU Style, Package
Series MTU type Case style # of Ports
2Series 2000
3Series 3000
4Series 4000
3Water MTU
2General
(8150)
1Single
2Dual
X X X X
Radio Behavior
Register type Read rate Range
RPulse
DEncoder
BHourly
(leave blank for 2 x daily)
WExtended
(leave blank for standard)
X X X X
Customization
Connector Wire Length
0None
1Nicor
2Badger
3Neptune
4Neptune wire prep
Length in feet(standard is 12 feet)
X X X
Series 3000 Water MTU General (8150)
Single
3 3 2 1Pulse Hourly
R BNone 12 feet
0 1 2
Step 1The customer requests an MTU for a residential, pulse type water meter with a single port that can provide hourly reads.
Step 2Engineering builds the MTU configuration number using the water key.
Step 3An order is placed in E1 for part 3321-012-RB with the description MTU, 2-WAY, PULSE, 1P, STD RNG, HRR.
Example:
- -
- -
Series MTU Part Numbering SystemWater Models
Introducing Aclara STAR Network Water and Gas MTUs with Two-Way Communication
Confidential Internal Communications
BACK TO PAGE 1
MTU Style, Package
Series MTU type Case style # of Ports
2Series 2000
3Series 3000
4Series 4000
1Direct Mount
2Indirect Mount
1General (7712)
2General (8150)
3Low profile AM
4Low profile RO
5Low profile SP
6Low profile DR
7Commercial
1Single
2Dual
X X X X
Customization
Connector Metermanufacturer
0 X X0
Generic(No drive)
1American
2Rockwell
3Sprague
4Lancaster
5Dresser
6Romet
0Universal
1-4Residential
5-9Commercial
Meter style
Radio Behavior
Register type Read rate Alarm
RPulse
BHourly
(leave blank for 2 x daily)
STamper
Detection
X X X XRange
WExtended
(leave blank for standard)
Series 3000 Direct Mount
Low Profile AM
Single
3 1 3 1
Step 1The customer requests a direct mount MTU for an American residential gas meter with a single port that can provide hourly reads and tamper protection.
Step 2Engineering builds the MTU configuration number using the gas key.
Step 3An order is placed in E1 for part 3131-011-RBS with the description MTU, 2-WAY, AMER,RES,STD,RNG, HRR
Example:
Pulse Hourly Tamper Detection
R B SAmerican
0 1 1Residential
- -
- -
Ordering Information
Series MTU Part Numbering SystemGas Models
Introducing Aclara STAR Network Water and Gas MTUs with Two-Way Communication
Confidential Internal Communications
BACK TO PAGE 1Upcoming Product Materials
As we get closer to our external launch of the MTU series, we will release several documents and provide training to help explain the features, benefits, and specifications of the product lines.
LiteratureThe following documents are planned to help describe the one- and two-way networks and MTU series products in more detail. (Subject to change)
Aclara water and gas one-way communication and two-way communication network brochureThis will describe and compare the benefits of both communication types in the water and gas industries.
Aclara MTU Series brochureThis brochure will describe the features, benefits, and compatibility of the entire MTU series for water and gas.
Product data sheetsEach data sheet will include a product description, value, features and benefits, and specifications.
Series 2000 Water MTU•Series 3000 Water MTU•Series 3000 Gas MTU•
Training programsTraining sessions/webinars on the series MTUs will be held for additional product information.
Product catalogA reference guide of series MTUs with descriptions, specifications, and part numbers.