test equipment dräger aerotest navy is used to monitor the … · 2019. 12. 3. · dräger...

6
Dräger Aerotest ® Navy Test Equipment Specially designed to meet the requirements of the Navy, the Dräger Aerotest ® Navy is used to monitor the purity of breathing air in the high pressure range. ST-1344-2004 Transport case Measuring device Instructions for Use Dräger Tubes® Pressure reducer Adapter 200/300 bar

Upload: others

Post on 03-Oct-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Test Equipment Dräger Aerotest Navy is used to monitor the … · 2019. 12. 3. · Dräger Aerotest® Navy | 03 ST-1179-2008 Dräger Aerotest® Simultan HP Dräger Aerotest® Simultan

Dräger Aerotest® NavyTest Equipment

Specially designed to meet the requirements of the Navy, theDräger Aerotest® Navy is used to monitor the purity of breathing air in thehigh pressure range.

ST-1

344-2

004

Transport case

Measuring device

Instructions for Use

Dräger Tubes®

Pressure reducer

Adapter 200/300

bar

Page 2: Test Equipment Dräger Aerotest Navy is used to monitor the … · 2019. 12. 3. · Dräger Aerotest® Navy | 03 ST-1179-2008 Dräger Aerotest® Simultan HP Dräger Aerotest® Simultan

Benefits

02 | Dräger Aerotest® Navy

Tested breathing air

Using the Dräger Aerotest Navy, it is possible to determine the quality of the breathing air which is suppliedby a compressor or a compressed gas cylinder (up to a maximum pressure of 300 bar). By means of the testsystem, the reliable testing of the breathing air is ensured according to the US navy standard.

Pollutant detection and measurement

The Dräger Aerotest Navy determines the quantity of various potential pollutants: It is possible to reliablydetermine carbon monoxide, carbon dioxide, hydro steam and oil in the compressed air either individuallyor simultaneously. Specifically adjusted to the different fields of application of the navy, this test system alsomeasures the oxygen amount of between 5% and 23% volume.

Fast and easy to use

The measuring device can be used independently of power supplies and, using conventional tools, can beconnected with a G5/8, CGA 347 or .825 -14 NGO-RH-EXT connector to the high-pressure compressed airsupply system to be monitored easily and without problems. After only five minutes, the quick check deliversprecise and reliable measurement results and informs about the degree of the contamination.

Always ready for use

All components of the Dräger Aerotest Navy are arranged in a compact, convenient case and ready for use.

Page 3: Test Equipment Dräger Aerotest Navy is used to monitor the … · 2019. 12. 3. · Dräger Aerotest® Navy | 03 ST-1179-2008 Dräger Aerotest® Simultan HP Dräger Aerotest® Simultan

Related Products

Dräger Aerotest® Navy | 03

ST-1

179-

2008

Dräger Aerotest® Simultan HP

Dräger Aerotest® Simultan HP is used to determine the quality ofrespiratory air in high-pressure applications. In combination with thenew Dräger Oil Impactor the system offers a unique quality level for themonitoring of compressed air.

D-5

7229

-201

2

Dräger OxyTest 2000

The Dräger Oxytest 2000 can determine the oxygen content of breathingair and oxygen mixtures, such as nitrox. This mobile testing system isindispensable, especially for professional diving applications.

Page 4: Test Equipment Dräger Aerotest Navy is used to monitor the … · 2019. 12. 3. · Dräger Aerotest® Navy | 03 ST-1179-2008 Dräger Aerotest® Simultan HP Dräger Aerotest® Simultan

Technical Data

04 | Dräger Aerotest® Navy

Dräger Aerotest® NavyDimensions of carrying case (L x W x H in mm) 400 x 300 x 91Weight (kg) approx. 3.0Operating temperature 15 °C to 25 °C, 1,013 mbarMin. operating pressure (bar) 10Primary pressure max. (bar) 300Flow rate (l/min) 0.2, 4.0; 1 strokeSupply pressure (set on delivery) (bar) 8.5

Ordering Information

Dräger Aerotest® Navy

Dräger Aerotest® Navy, complete, comprising: 65 25 9601 pressure reducer with hand-tight connection1 measuring device for 4 tubes2 adapters1 stopwatch1 break-off facility for tubes, Dräger TO 70001 box of 10 Dräger-Tubes®, carbon dioxide (CO2) 100/a-P

1 box of 10 Dräger-Tubes®, carbon monoxide (CO) 5/a-P1 box of 10 Dräger-Tubes®, water vapour (H2O) 20/a-P

1 box of 10 Dräger-Tubes®, 10 DR Oil PN1 box of 8 Dräger-Tubes® plus 2 connecting tubes8 DR oxygen (O2) 5% B

1 accuro gas detector pump1 set of spare parts for accuro gas detector pump1 bubble test1 Instructions for Use1 transport case (blue)

Dräger Aerotest® Navy, without Dräger-Tubes® andDräger accuro gas detector pump

65 25 970

Page 5: Test Equipment Dräger Aerotest Navy is used to monitor the … · 2019. 12. 3. · Dräger Aerotest® Navy | 03 ST-1179-2008 Dräger Aerotest® Simultan HP Dräger Aerotest® Simultan

Notes

Dräger Aerotest® Navy | 05

Page 6: Test Equipment Dräger Aerotest Navy is used to monitor the … · 2019. 12. 3. · Dräger Aerotest® Navy | 03 ST-1179-2008 Dräger Aerotest® Simultan HP Dräger Aerotest® Simultan

Notes

06 | Dräger Aerotest® Navy

Not all products, features, or services are for sale in all countries.Mentioned Trademarks are only registered in certain countries and not necessarily in the countryin which this material is released. Go to www.draeger.com/trademarks to find the current status.

CORPORATE HEADQUARTERSDrägerwerk AG & Co. KGaAMoislinger Allee 53–5523558 Lübeck, Germanywww.draeger.com

REGION DACHDräger Safety AG & Co. KGaARevalstraße 123560 Lübeck, GermanyTel +49 451 882 0Fax +49 451 882 [email protected]

REGION EUROPEDräger Safety AG & Co. KGaARevalstraße 123560 Lübeck, GermanyTel +49 451 882 0Fax +49 451 882 [email protected]

REGION MIDDLE EAST, AFRICADräger Safety AG & Co. KGaABranch OfficeP.O. Box 505108Dubai, United Arab EmiratesTel +971 4 4294 600Fax +971 4 4294 [email protected]

REGION ASIA PACIFICDraeger Singapore Pte. Ltd.25 International Business Park#04-20/21 German CentreSingapore 609916Tel +65 6308 9400Fax +65 6308 [email protected]

REGION CENTRALAND SOUTH AMERICADräger Panama S. de R.L.59 East Street, Nuevo PaitillaHouse 30, San Francisco TownPanama City, PanamaTel +507 377 9100Fax +507 377 [email protected]

Locate your Regional SalesRepresentative at:www.draeger.com/contact

90 4

6 65

1 |

18.0

2-4

| H

Q |

PP

| S

ubje

ct to

mod

ifica

tions

| ©

201

8 D

räge

rwer

k AG

& C

o. K