4
TÜV Rheinland LGA Products GmbH Furniture Test Institute Nuremberg TÜVRheinland ® LGAI~I Reported to: König Komfort + Rennsitze GmbH Steinbeisstraße 5 74360 Ilsfeld Gemany Test- report No 21147863-2-001 Order-No. 1055747-2 Object: Order: Monitoring chair s with and without sliding seat König SECUR 24 Basic and Exc1usive König Office-Line OL 210-N and OL 300-N BMA SECUR 24 Basic and Exc1usive (3 reference sampies supplied by the manufacturer) Test to British Standard 5459 Part 2, ed. 2000 Franz Rackl Test Officer Findings: The monotoring chair models "König SECUR 24 Basic and Exc1usive" König Office-Line OL 210-N and OL 300-N, BMA SECUR 24 Basic and Exc1usive were tested in accordance with the guidelines laid out in British Standard BS 5459 Part 2, ed. 2000. The test methods and requirements of this standard are for users up to a weight of 150 kg and a daily use of up to 24 hours. In summary it can be stated, that the monotoring chair models" König SECUR 24 Basic and Ex- c1usive "König Office-Line OL 210-N and OL 300-N, BMA SECUR 24 Basic and Exc1usive meet the requirements ofBritish Standard BS 5459 : Part 2. The following pages contain technical data and details of the test. Nuremberg,2010-03-30 569 hy/ra/~e TÜV Rheinland LGA Products GmbH Furniture Test Institute /r:f( Dip!. lng. (FH R. Heym Head of Co petence Centre / This test re,/rt consists of 6 pages. Except when otherwise approved / licensed by LGA this test report may only be published and used in unagbreviated original phrasing and form. The test report contains the result of one single examination of the individual test sampIe and does not represent any universally valid evaluation of the quaIWes of all products from serial production. Should the con- tent of the test report need any interpretation the German text shall be leading. P:\QMBL\QMBLN\Berichle\2010\21147863-2-001.doc TÜV Rheinland LGA Products GmbH Tillyslraße 2· 90431 Nürnberg Tel. +49911-655-5831 • Fax +49911-655-5834 eMail: [email protected] www.luv.com/safely page 1 of 4 Residence and register court Nürnberg HRB 20613 Managing Oireclors: Hans-Hermann Ueffing, Jörg Mähler Tax-No: 216/5715/1213 VAT No: OE 811835490

Upload: ngotram

Post on 04-Mar-2018

215 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Test- report - BMA ergonomics · PDF fileTest to British Standard 5459 Part 2, ed. 2000 ... The test report contains the result of one single examination of the ... Tel. +49911-655-5831

TÜV Rheinland LGA Products GmbHFurniture Test Institute Nuremberg

TÜVRheinland ®

LGAI~I

Reported to: König Komfort + Rennsitze GmbHSteinbeisstraße 574360 IlsfeldGemany

Test-reportNo 21147863-2-001Order-No. 1055747-2

Object:

Order:

Monitoring chair s with and without sliding seatKönig SECUR 24 Basic and Exc1usiveKönig Office-Line OL 210-N and OL 300-NBMA SECUR 24 Basic and Exc1usive(3 reference sampies supplied by the manufacturer)

Test to British Standard 5459 Part 2, ed. 2000

Franz RacklTest Officer

Findings:The monotoring chair models "König SECUR 24 Basic and Exc1usive" König Office-LineOL 210-N and OL 300-N, BMA SECUR 24 Basic and Exc1usive were tested in accordancewith the guidelines laid out in British Standard BS 5459 Part 2, ed. 2000.The test methods and requirements of this standard are for users up to a weight of 150 kgand a daily use of up to 24 hours.In summary it can be stated, that the monotoring chair models" König SECUR 24 Basic and Ex-c1usive "König Office-Line OL 210-N and OL 300-N, BMA SECUR 24 Basic andExc1usive meet the requirements ofBritish Standard BS 5459 : Part 2.

The following pages contain technical data and details of the test.

Nuremberg,2010-03-30569 hy/ra/~e

TÜV RheinlandLGA Products GmbHFurniture Test Institute

/r:f(Dip!. lng. (FH R. HeymHead of Co petence Centre

/

This test re,/rt consists of 6 pages. Except when otherwise approved / licensed by LGA this test report may only be published andused in unagbreviated original phrasing and form. The test report contains the result of one single examination of the individual testsampIe and does not represent any universally valid evaluation of the quaIWes of all products from serial production. Should the con-tent of the test report need any interpretation the German text shall be leading.

P:\QMBL\QMBLN\Berichle\2010\21147863-2-001.doc

TÜV Rheinland LGA Products GmbHTillyslraße 2· 90431 NürnbergTel. +49911-655-5831 • Fax +49911-655-5834eMail: [email protected] • www.luv.com/safely

page 1 of 4

Residence and register court Nürnberg HRB 20613Managing Oireclors: Hans-Hermann Ueffing, Jörg MählerTax-No: 216/5715/1213 VAT No: OE 811835490

Page 2: Test- report - BMA ergonomics · PDF fileTest to British Standard 5459 Part 2, ed. 2000 ... The test report contains the result of one single examination of the ... Tel. +49911-655-5831

TÜV Rheinland LGA Products GmbHFurniture Test Institute Nuremberg

Test Results

Object

TÜVRheinland ®

LGA~INo. 21147863-2-001Order no. 1055747-2

Article:

Article no.:

Number of samples:SamplesDelivered by:

Delivered:Reg. No.:

Scope of testsGeneral examination

Monitoring chairs (with and without sliding seat)

König SECUR 24 Basic and ExclusiveKönig Office-Line OL 21O-N and OL 300-NBMA SECUR 24 Basic and Exclusive

3 reference samples + several gas lifts

König Komfort + Rennsitze GmbH andBMA-ERGONOMICS BV30.11.,22.12.2009,15.02. and 10.03.201010028981-1/2,30056,32006 and 32910

Technical test in accordance with BS 5459 : 2000

Applicability of test resultsThe test results refer solely to the samples tested. The digital pictures shown in this report are foradditional information only and are not part of this report.

Measurement incertaintyUnless otherwise stated all dimensions are measured to an accuracy according to DIN 7168-g forold constructions resp. DIN ISO 2768 part 1 "c" for new constructions. For all other physical val-ues the measurement incertainty is < 5 %.The test has been carried out at standard climate 23°C/50 % r.h.

P:\QMBL \QMBLN\Berichte\201 0\2114 7863-2-001.docl Seite 2 von 4

Page 3: Test- report - BMA ergonomics · PDF fileTest to British Standard 5459 Part 2, ed. 2000 ... The test report contains the result of one single examination of the ... Tel. +49911-655-5831

TÜV Rheinland LGA Products GmbHFurniture Test Institute Nuremberg

TÜVRheinland ®

LGAI~INo. 21147863-2-001Order no. 1055747-2

General examination

Brief description of the sampies• Seat height adjustable by means of gas spring

from STABILUS• Denomination of gas spring: Stab 0 Mat

DIN 4550-4 203901 500 N 362 09 Rl• Seat mechanism made of aluminum die cast

with tilt action variable blockableby means of a Bloc 0 Lift gas spring

• Initial tension adjustable by means ofrotaion knob

• Sliding seat adjustable in 8 positions• Separate backrest inclination variable

adjustable by hand wheel• Lumbal support variable adjustable in height

and depth• Foldable armrests adjustable in inclination• Base made of aluminum die cast (AL G350)• 5 brake unloaded twin wheel swivel castors

type "H" and "W"• Lettering of castors: Move 60• Castor manufacturer: Gross + Froelich

P:\QMBL\QMBLN\Berichte\2010\21147863-2-001.docl Seite 3 von 4

Page 4: Test- report - BMA ergonomics · PDF fileTest to British Standard 5459 Part 2, ed. 2000 ... The test report contains the result of one single examination of the ... Tel. +49911-655-5831

TÜV Rheinland LGA Products GmbHFurniture Test Institute Nuremberg

TÜVRheinland ®

LGAI~INo. 21147863-2-001Order no. 1055747-2

ummary 0 es san resu sClause Test description Test parameters Title

A.5.1 Fore-and-aft safety Seat loadV, 10400N passBack load H, 400 NFront edgeload V2 10400 Nmax. number of cycles 500.000

A.5.2 Seat impact Drop height 350 mm pass

A.5.3 Back impact Drop height 330 mm passAngle 48°

A.5A Drop Drop height 450 mm pass

A.5.5 Side-to-side safety Load 1.200 N passmax. number of cycles 250.000

A.6.2.\ Forward overtuming Load 600 N; 20 N pass

A.6.2.2 Sideways overtuming Load 350 N; 250 N; 20 N

A:6A Rearward overturning 13 discs

A.6.3.2 Accidental rearward See clause A.6.3.2 passOvertuming

A7.2 Arm sideway static load Horizontal force 600 N pass

A7.3 Arm down ward static load Vertical force 1.200 N pass

A.7A Arm impact Angle 48° pass

A.7.5 Chair swivelling Vertical force 1.200N passCycles 100.000

A.7.6 Seat height adjustment Vertical force 1.200 N, pass

10000 Cycles

A.7.9 Locking device fatigue Back load H, 400N passCycles 500.000

Requirements to BS 5459, ed. 2000S [t t d h