test report no l026/...
TRANSCRIPT
![Page 1: TEST REPORT No l026/ 19,0'1.20'17activefuel.de/wp-content/uploads/2017/09/ISO-16750-Original.pdf · BULGARIAN INSTITUTE OF METROLOGY ACCREDITED EMC TESTING LABORATORY Solla, quarter](https://reader036.vdocument.in/reader036/viewer/2022081522/5fb47d08f8446a516d711d7f/html5/thumbnails/1.jpg)
vBULGARIAN INSTITUTE OF METROLOGY
ACCREDITED EMC TESTING LABORATORYSofia, quader "Poligona",2 "Prof. P. Mutalchiov" str.
Certificato for accroditation rcg No 257 nU I 17.03.2016lvalid until 20,05.20'18issued by EA BAS according to standa.d BDS EN ISO/lEC 17025:2006
Sheet ITotalsheets 9
TEST REPORT
No l026/ 19,0'1.20'17
3. Manufacturer:
4, Standards:
1. Equipmenl und€rte3t:
2. Appllcant:
Eleckonic fuel activatortype EFA-120
Ecomoto Engineering Ltd.Sofia. Petko Karavelov str. bl. 62, etr 6, ap.21
Ecomoto Engineedng Ltd.
BDS ISO 16750-2:20'15 - p. 4.6.4
'l sample., S/N 463874241
No AY-02-1297126.08.2016
26 .09 .2016 , 17 .01 .2017
26 .09 .2016 , 17 .01 .2017
5. Number of tested samDlo:
6.
7.
Numb€r and date of order:
Date of receiving EUT:
8. Date ofmeasutement:
Head of E[rC Testing laboratory:
Assoc. Prof. N. Pa
e-mail: [email protected] fax (+359 2) 8762 819httpJ/www.bim.government.bg
Test report No 1026 / 19.01.20'17
![Page 2: TEST REPORT No l026/ 19,0'1.20'17activefuel.de/wp-content/uploads/2017/09/ISO-16750-Original.pdf · BULGARIAN INSTITUTE OF METROLOGY ACCREDITED EMC TESTING LABORATORY Solla, quarter](https://reader036.vdocument.in/reader036/viewer/2022081522/5fb47d08f8446a516d711d7f/html5/thumbnails/2.jpg)
BULGARIAN INSTITUTE OF METROLOGY
ACCREDITED EMC TESTING LABORATORYSolla, quarter "Pollgona",2 "Prof. P, Mutafchiev" str.
Certiticate for accreditation reg No 257 nW 17.03.2016 lralid until 20.05.2018issued by EA BAS accordlng to standard BDS EN ISO/IEC 17025:2006
Sheel2Total sheets I
9. Applled standards ror used testlng methods
BDS ISO 16750-212015 Road vehicles - Environmental conditions and t€sting foreleckical and eleclronic equipmentPart 2t Electrical loads
e-mail: [email protected] (+359 2) 8762 819httpJ/wwwbim.govemment.bg
Test report No 1026 / 19.01.2017
![Page 3: TEST REPORT No l026/ 19,0'1.20'17activefuel.de/wp-content/uploads/2017/09/ISO-16750-Original.pdf · BULGARIAN INSTITUTE OF METROLOGY ACCREDITED EMC TESTING LABORATORY Solla, quarter](https://reader036.vdocument.in/reader036/viewer/2022081522/5fb47d08f8446a516d711d7f/html5/thumbnails/3.jpg)
BULGARIAN INSTITUTE OF METROLOGY
ACCREDITED EMC TESTING LABORATORYSotia, quarter "Poligona", 2 "Prof. P. Mulafchiev" str.
Certificate tor accreditatlon reg No 257 na '17.03.2016 lvalid unti|20.05.2018issued bv EA BAS according to standard BDS EN ISO/lEC 17025:2006
Sheet 3Total sheets 9
10, Test condit ion'10.1 Environmental condit ion
TemperatureRelative humidityPressute
10.2 Power Supply:
Equipment under test is powered with
10.3 Configurationsl
from 20,5 "C to 21,3 'C
from 30,3 % RH to 44,6 o/o RHfrom 94,9 kPa to 95,2 kPa
12 V DC and 24 V DC.
e-mail: [email protected] ,ifax (+359 2)8762 819htlp://www.bim.government.bg
Test report No 1026 / 19.01.2017
![Page 4: TEST REPORT No l026/ 19,0'1.20'17activefuel.de/wp-content/uploads/2017/09/ISO-16750-Original.pdf · BULGARIAN INSTITUTE OF METROLOGY ACCREDITED EMC TESTING LABORATORY Solla, quarter](https://reader036.vdocument.in/reader036/viewer/2022081522/5fb47d08f8446a516d711d7f/html5/thumbnails/4.jpg)
![Page 5: TEST REPORT No l026/ 19,0'1.20'17activefuel.de/wp-content/uploads/2017/09/ISO-16750-Original.pdf · BULGARIAN INSTITUTE OF METROLOGY ACCREDITED EMC TESTING LABORATORY Solla, quarter](https://reader036.vdocument.in/reader036/viewer/2022081522/5fb47d08f8446a516d711d7f/html5/thumbnails/5.jpg)
BULGARIAN INSTITUTE OF METROLOGY
ACCREDITED EMC TESTING LABORATORYSotla, quarter "Poligona", 2 "Prof. P. Mutafchiev" str.
Certificate for accredftatlon reg No 257 nW 17.03.2016lvalid untll 20.05.2018iasued by EA BAS according to standard BDS EN ISO/IEC 17025:2006
Sheet 5Total sheets 9
I1. RESULTS
CONTENTS
Index pags
'11.1 lmmunityto transient electricalconductivity in power lines - pulses 5a (test A) and 65b (test B)
e-mail: [email protected] fax (+359 2) 8762 819httpJ/www.bim.govemment.bg
Test report No 1026 / 19.01.2017
![Page 6: TEST REPORT No l026/ 19,0'1.20'17activefuel.de/wp-content/uploads/2017/09/ISO-16750-Original.pdf · BULGARIAN INSTITUTE OF METROLOGY ACCREDITED EMC TESTING LABORATORY Solla, quarter](https://reader036.vdocument.in/reader036/viewer/2022081522/5fb47d08f8446a516d711d7f/html5/thumbnails/6.jpg)
BULGARIAN INSTITUTE OF METROLOGY
ACCREDITED EMC TESTING LABORATORYSofla, quarter "Poligona",2 "Prof. P. Mutafchiev" str.
Cortificate for accreditation reg No 257 nW 17.03.20'16lvalid until20-05,20't8issued by EA BAS accordinq to alandard BDS EN ISO/IEC 17025:2006
Shee16Total sheets I
'l1.1 lmmunlty to tranaient €lectrical conductivity in power lines - pulsEs 5a (tost A) and 5b(tost B)
Standard: BDS ISO 16750-2:2015
Method: BDS ISO 16750-212015 - p.4.6.4.2.2 and p. 4.6.4.2.3
Acceptance criteda : According to p.4.6.4.3 of BDS ISO 16750-2:2015
Pulse paramoters : Pulse 5a (test A) Pulse 5b (test B)
Ua: 12V 24V 12V 24V
Us€: 101 V 202V ' i01 V 2O2V
Us suppressedr 35 V 58 V
t r : sms sms sms sms
td: 400 ms 350 ms 400 ms 350 ms
Ria : 4A 8c ) 40 8C)
Period botween pulses: 60 s 60 s 60 s 60 s
Number of pulses: 10 10 5 5
Working regim6: Standby
Result: No failures
Deviatlon from the method: No deviation from the method
Note:
e-mail: [email protected] fax (+359 2) 8762 819httpJ/wwwbim.governmenl.bg
Test rcpott No 1026 / 19.01.2017
![Page 7: TEST REPORT No l026/ 19,0'1.20'17activefuel.de/wp-content/uploads/2017/09/ISO-16750-Original.pdf · BULGARIAN INSTITUTE OF METROLOGY ACCREDITED EMC TESTING LABORATORY Solla, quarter](https://reader036.vdocument.in/reader036/viewer/2022081522/5fb47d08f8446a516d711d7f/html5/thumbnails/7.jpg)
BULGARIAN INSTITUTE OF METROLOGY
ACCREDITED EMC TESTING LABORATORYSofia, quarter "Poligona", 2 "Prof. P. Mutafchiev" str.
Certfficato for accrcditation reg No 257 nW 17.03,2016 lvalid unti|20.05.2018lssued by EA BAS accordlng to standard BDS EN ISO/IEC 17025:2006
Shee17Total sheets 9
O,S1ur-U^1*ll
0,1(trr-U^)+Ua
0
Fig. 'l Puls€ 5a shape (test A)
Uq0,9(Us'UlJ + U;
0 ,1 (Us"Ud+U^UA
0
Fig. 2 Pulse 5b shape (test B)
e-mail: [email protected],ifax (+359 2) 8762 819htlpJ/www.bim.govemment.bg
Tsst repod No 1026 / 19.01.2017
![Page 8: TEST REPORT No l026/ 19,0'1.20'17activefuel.de/wp-content/uploads/2017/09/ISO-16750-Original.pdf · BULGARIAN INSTITUTE OF METROLOGY ACCREDITED EMC TESTING LABORATORY Solla, quarter](https://reader036.vdocument.in/reader036/viewer/2022081522/5fb47d08f8446a516d711d7f/html5/thumbnails/8.jpg)
BULGARIAN INSTITUTE OF METROLOGY
ACCREDITED EMC TESTING LABORATORYSofia, quarter "Poligona", 2 "Prof. P. Mutafchiev" str.
Certificate for accreditation reg No 257 nW 17.03.2016 lvalid unti120,05,20't8issued by EA BAS according to standard BDS EN ISO/IEC 17025:2006
Sheel8Total sheels 9
11.' l . l Used test 6quipment:
Type Mod€l Manufacturer S/N
Automatictest NSG5000 SCHAFFNERLtd. 199905-224EK 4706-D-K-15033-01-00system / 02.02.2016 TESEO GmbH
4707-D-K-15033-01-00/ 01.02.2016 TESEO GmbH4708-D,K-15033-01-00/ 02.02.2016 TESEQ GmbH
Battery NSG 5004- SCHAFFNER Ltd. 20O002-102DP 4708-D-K-1503341-00
Cedifical6 for calibmlion
i 01.02.2016IESEO GmbH
simufator 125A / 02.02.2016 TESEQ GmbH
High energy NSG 5005A SCHAFFNER Ltd. 18(750- 4706-O-K-1s0s3-01-00pulse genorator 0005104-00) i 02 02 2016 TESEO GmbH
Output INA 5025 SCHAFFNER Ltd. 20005-0011N 4707-D-K-15033-01-00impedancosimulator
11,,|,2. Used software:
Manufacturer Name Version Year/Build
Schaffner Instrument Autostar 4.02-06 2005
e-mail: emclab@abv-bgPhone fiax (+359 2) 8762 819http://www-bim.govemment.bg
Tesl rcporl No 1026 / 19.01.2017
![Page 9: TEST REPORT No l026/ 19,0'1.20'17activefuel.de/wp-content/uploads/2017/09/ISO-16750-Original.pdf · BULGARIAN INSTITUTE OF METROLOGY ACCREDITED EMC TESTING LABORATORY Solla, quarter](https://reader036.vdocument.in/reader036/viewer/2022081522/5fb47d08f8446a516d711d7f/html5/thumbnails/9.jpg)
BULGARIAN INSTITUTE OF METROLOGY
ACCREDITED EMG TESTING LABORATORYSofia, quarter "Poligona", 2 "Prof, P. Mutafchiev" str.
Certfficale for accr€ditation 169 No 257 nW 17,03,2016lvalld unti|20.05.2018issuod by EA BAS according to standard BDS EN ISO/IEC 17025:2006
NOTES:
Sheet ITotal sheels I
The results could be related only to the testing sample.Coping of the test reportforbidden without written consent of the testing laboralory.
The reported expanded uncgrtainty of measurement is stated as the combined standard uncertainty ofmeasurement multiplied by a covorago factor of k=2, witch for a normal dist bution coresponds to acoverage probability of approximately 95 %
T€st p€rform€d by:
Borislava l\4edzhidieva
Hoad of Testing laboratory "EMC":
Assoc. Prof. N. Panteleev Ph.D
1 .2.
e-mailr [email protected] fax (+359 2) 8762 819httpJ rwwbim.govemment.bg
Test report No 1026 / 19.01.20'17