test report on behalf of jiangmen oneder industrial co.,ltd … resistencia al fuego manilla... ·...

19
Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China Tel.: +86-755-27454498, Email: [email protected] Report No.: B-S171215807 Page 1 of 24 TEST REPORT On Behalf of Jiangmen oneder industrial Co.,LTD Prepared For : Jiangmen oneder industrial Co.,LTD No.12, Duruan road north two, Pengjiang, Jiangmen, Guangdong, China Prepared By : Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China Date of Test : Sep. 10-28,2017 Date of Report : Sep.29, 2017 Report Number : B-S171215807

Upload: others

Post on 06-Oct-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TEST REPORT On Behalf of Jiangmen oneder industrial Co.,LTD … resistencia al fuego manilla... · Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang,

Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China Tel.: +86-755-27454498, Email: [email protected]

Report No.: B-S171215807

Page 1 of 24

TEST REPORT

On Behalf of

Jiangmen oneder industrial Co.,LTD

Prepared For : Jiangmen oneder industrial Co.,LTD

No.12, Duruan road north two, Pengjiang, Jiangmen, Guangdong, China

Prepared By : Beide (SHENZHEN) Product Service Limited

6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China

Date of Test : : Sep. 10-28,2017

Date of Report : : Sep.29, 2017

Report Number : : B-S171215807

Page 2: TEST REPORT On Behalf of Jiangmen oneder industrial Co.,LTD … resistencia al fuego manilla... · Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang,

Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China Tel.: +86-755-27454498, Email: [email protected]

Report No.: B-S171215807

Page 2 of 24

Test Report

EN 1634-1 Fire resistance and smoke control tests for door and

shutter assemblies, openable windows and elements of building hardware

Part 1: Fire resistance test for door and shutter assemblies and openable windows

Testing laboratory …………………...... : Beide (SHENZHEN) Product Service Limited

Address ……………………………….... : 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen,

China

Report body.........…………………….... : Beide (SHENZHEN) Product Service Limited

Address (China) ………………………. : 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen,

China

Applicant ……………………………….. : Jiangmen oneder industrial Co.,LTD

Address ………………………………….: No.12, Duruan road north two, Pengjiang, Jiangmen, Guangdong, China

Client No…………………………………: 07505898

Standard ……………………………….. : EN 1634-1:2014

Test Result …………………………….. : Compliance with

EN 1634-1:2014

Procedure deviation …………………... : N.A.

Non-standard test method …………….: N.A.

Type of test object …………………….. : Lever handles

Trademark ……………………………... : N.A.

Model/type reference ………………..... : OD-TH101

Manufacturer …………………………... : Jiangmen oneder industrial Co.,LTD

Address ……………………………….... : No.12, Duruan road north two, Pengjiang, Jiangmen, Guangdong, China

Page 3: TEST REPORT On Behalf of Jiangmen oneder industrial Co.,LTD … resistencia al fuego manilla... · Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang,

Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China Tel.: +86-755-27454498, Email: [email protected]

Report No.: B-S171215807

Page 3 of 19

General remarks This report shall not be reproduced except in full without the written approval of the testing laboratory.

The test results presented in this report relate only to the item(s) tested.

"(see appended table)" refers to a table appended to the report.

“(see remark #)” refers to a remark appended to the report.

“(see Annex #)" refers to an annex appended to the report.

Throughout this report a comma (point) is used as the decimal separator.

Remark:

Photo view:

(See appendix 1)

Page 4: TEST REPORT On Behalf of Jiangmen oneder industrial Co.,LTD … resistencia al fuego manilla... · Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang,

Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China Tel.: +86-755-27454498, Email: [email protected]

Report No.: B-S171215807

Page 4 of 19

Possible test case verdicts :

Test case does not apply to the test object …….. : N (.A.)

Test object does meet the requirement …….…… : P(ass)

Test object does not meet the requirement ……. : F(ail)

Test by : Beide (SHENZHEN) Product Service Limited .

6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an

Dist, Shenzhen, China

Reported by : Sep.28,2017 Signature / Rocky Date

Checked by : Sep.28,2017 Signature / Apollo Date

Approved by : Sep.29,2017 Signature / Bruce Date

Page 5: TEST REPORT On Behalf of Jiangmen oneder industrial Co.,LTD … resistencia al fuego manilla... · Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang,

EN 1634-1

Clause Requirement Test Result - Remark Verdict

Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China Tel.: +86-755-27454498, Email: [email protected]

Report No.: B-S171215807

Page 5 of 19

6 Test specimen P

6.1 General P

6.2 Size P

6.3 Number P

6.4 Design P

6.5 Construction P

6.6 Verification P

6.7 Building hardware P

7 Installation of test specimen P

7.1 General P

7.2 Supporting construction P

7.2.1 General P

7.2.2 Standard supporting construction P

7.2.3 Erection of standard supporting and associated supporting constructions

P

7.3 Gaps P

8 Conditioning P

8.1 Moisture content P

8.2 Mechanical P

9 Application of instrumentation P

9.1 Thermocouples P

9.1.1 Furnace thermocouples (plate thermometers) P

9.1.2 Unexposed face thermocouples P

9.1.2.1 General P

9.1.2.2 Average temperature P

9.1.2.3 Maximum temperature P

9.1.2.3.1 General P

9.1.2.3.2 Temperature of frame P

9.1.2.3.3 Temperature of door leaf or shutter P

9.1.2.3.4 Temperatures of other areas P

9.1.2.4 Maximum temperature (supplementary procedure)

P

9.1.2.4.1 General P

Page 6: TEST REPORT On Behalf of Jiangmen oneder industrial Co.,LTD … resistencia al fuego manilla... · Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang,

EN 1634-1

Clause Requirement Test Result - Remark Verdict

Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China Tel.: +86-755-27454498, Email: [email protected]

Report No.: B-S171215807

Page 6 of 19

9.1.2.4.2 Temperature of door leaf or shutter P

9.1.2.4.3 Temperature of other areas P

9.2 Pressure P

9.3 Deflection P

9.4 Radiation N

10 Test procedure P

10.1 Pre-test examination and preparation P

10.1.1 General P

10.1.2 Gap measurements P

10.1.3 Closing force measurements P

10.1.4 Final setting P

10.2 Fire resistance test P

10.2.1 General P

10.2.2 Integrity P

10.2.3 Insulation P

10.2.4 Radiation N

11 Performance criteria P

11.1 Integrity P

11.2 Insulation P

11.2.1 General P

11.2.2 Discrete areas P

11.2.3 Average temperature rise P

11.2.4 Maximum temperature rise (normal procedure - Classification I2 according to EN 13501-2)

P

11.2.5 Maximum temperature rise (supplementary procedure - Classification I1 according to EN 13501-2)

P

11.3 Radiation P

12 Test report P

In addition to the items required by EN 1363-1, the following shall also be included in the test report:

P

a) reference that the test was carried out in accordance with EN 1634-1;

EN1634-1 P

b) details of how the test specimen was verified P

Page 7: TEST REPORT On Behalf of Jiangmen oneder industrial Co.,LTD … resistencia al fuego manilla... · Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang,

EN 1634-1

Clause Requirement Test Result - Remark Verdict

Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China Tel.: +86-755-27454498, Email: [email protected]

Report No.: B-S171215807

Page 7 of 19

as described in 6.6;

c) reference to which standard supporting construction was chosen, if appropriate;

P

d) description of the associated supporting construction, if appropriate; the constructional details of the associated supporting construction shall be verified in the same way and shall be as thoroughly described as those of the test specimen;

P

e) information concerning the conditioning of the supporting construction in the light of the relaxations allowed in Annex A;

P

f) description of the type of floor covering, if any, used in the test construction;

P

g) gap measures as required by 10.1.2 and the permitted gap size as in 13.3.3.2.5;

P

h) closing forces as required by 10.1.3 including, if the test specimen was locked, latched or held in the closed position by a closing device during the test;

P

i) information concerning any mechanical conditioning performed upon the test specimen;

P

j) results stated in terms of the elapsed time, in completed minutes, between the commencement of the test and the time to failure of integrity and, when required, the time to failure of insulation under the normal and, if appropriate, the supplementary procedure and, where required, the full time history of the radiation as specified in EN 1363-2; the results shall be reported on each of the performance criteria listed in Clause 11;

P

k) in cases where the sponsor has requested that the test be continued beyond the first failure, all other failures shall also be recorded.

P

l) reference to the full test report; P

m) name of the producer/supplier of the item of building hardware under test; its trade name and/or the manufacturer's code for the product, a visual representation and a full description of the product including any protection, with particular reference to dimension of components, location and fixing details and materials used within the building hardware items;

P

n) full description of any intumescent or ablative protection applied adjacent to the item of building hardware

P

o) duration for which the test specimen complied with the relevant criteria, expressed in minutes from the start of the test;

P

p) full description of the test specimen including construction, dimensions, mass, direction of

P

Page 8: TEST REPORT On Behalf of Jiangmen oneder industrial Co.,LTD … resistencia al fuego manilla... · Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang,

EN 1634-1

Clause Requirement Test Result - Remark Verdict

Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China Tel.: +86-755-27454498, Email: [email protected]

Report No.: B-S171215807

Page 8 of 19

opening, fixing method, all items of hardware and materials.

13 Field of direct application of test results P

13.1 General P

13.2 Materials and construction P

13.2.1 General P

13.2.2 Specific restrictions on materials and construction

P

13.2.2.1 Timber construction P

13.2.2.2 Metal construction P

13.2.2.3 Glazed constructions P

13.2.3 Decorative finishes P

13.2.3.1 Paint P

13.2.3.2 Decorative laminates P

13.2.4 Fixings P

13.2.5 Building hardware P

13.3 Permissible size variations P

13.3.1 General P

13.3.2 Test periods P

13.3.3 Size variation related to product type P

13.3.3.1 General P

13.3.3.2 Hinged and pivoted doorsets and openable windows

P

13.3.3.2.1 For size variations (see Annex B) P

13.3.3.2.2 Other changes P

13.3.3.2.3 Side and transom panels P

13.3.3.2.4 Timber constructions P

13.3.3.2.5 Gaps P

13.3.3.3 Horizontally sliding and vertically sliding doorsets including sectional doors

P

13.3.3.4 Steel single skin folding shutters (uninsulated) P

13.3.3.5 Sliding and folding doorsets (insulated) P

13.3.3.6 Rolling shutter doorsets P

13.3.3.7 Operable fabric curtains P

13.4 Asymmetrical assemblies P

13.4.1 General P

Page 9: TEST REPORT On Behalf of Jiangmen oneder industrial Co.,LTD … resistencia al fuego manilla... · Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang,

EN 1634-1

Clause Requirement Test Result - Remark Verdict

Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China Tel.: +86-755-27454498, Email: [email protected]

Report No.: B-S171215807

Page 9 of 19

13.4.2 Specific rules P

13.5 Supporting constructions P

13.5.1 General P

13.5.2 Rigid standard supporting constructions (high or low density)

P

13.5.3 Flexible standard supporting constructions P

13.5.4 Specific rules for hinged or pivoted doorsets P

13.6 Associated supporting constructions P

Page 10: TEST REPORT On Behalf of Jiangmen oneder industrial Co.,LTD … resistencia al fuego manilla... · Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang,

EN 1634-1

Clause Requirement Test Result - Remark Verdict

Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China Tel.: +86-755-27454498, Email: [email protected]

Report No.: B-S171215807

Page 10 of 19

Page 11: TEST REPORT On Behalf of Jiangmen oneder industrial Co.,LTD … resistencia al fuego manilla... · Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang,

EN 1634-1

Clause Requirement Test Result - Remark Verdict

Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China Tel.: +86-755-27454498, Email: [email protected]

Report No.: B-S171215807

Page 11 of 19

ltem Description

1. Door Set

Frame

i. overall size

: 97 mm×56 mm with 56 wide×18 mm

deep rebate

ii. Fixingmethod ii.fixing method

: self adhered into grooves within the

rebate of the frame sections

Door Leaf

i. lippings

: Sapele hardwood 54 mm wide×8 mm

thick along the vertical edges

2. Hinges

Manufacturer : Jiangmen oneder industrial co.,LTD

Reference : 4"× 4"

Material : Stainless steel

Overall sizes

i. knuckle : 106 mm long × 14.2 mm diameter

ii. blades

: 101 mm long × 42 mm wide × 3 mm thick

Fixings

i. type : Countersunk head wood screws

ii. material : Steel

iii. size : 31 mm long × 4.8 mm diameter

iv. number off per blade : 4

v. maximum distance of fixing screws

from exposed face of door leaf : 32 mm

Bedding material

i. overall size : 101 mm long × 42 mm wide × 2 mm thick

3.Hinges

Manufacturer : Jiangmen oneder industrial co.,LTD

Reference : 3" x 4"

Material : Stainless steel

Overall sizes

i. knuckle : 106 mm long × 14.2 mm diameter

Page 12: TEST REPORT On Behalf of Jiangmen oneder industrial Co.,LTD … resistencia al fuego manilla... · Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang,

EN 1634-1

Clause Requirement Test Result - Remark Verdict

Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China Tel.: +86-755-27454498, Email: [email protected]

Report No.: B-S171215807

Page 12 of 19

ii. blades : 101 mm long × 29.5 mm wide × 3 mm

thick

Fixings

i. type : Countersunk head wood screws

ii. material : Steel

iii. size : 31 mm long × 4.8 mm diameter

iv. number off per blade : 4

v. maximum distance of fixing screws

from exposed face of door leaf : 19.5 mm

Bedding material

i. overall size

: 101 mm long × 29.5 mm wide × 2 mm thick

4.Hinges

Manufacturer : Jiangmen oneder industrial co.,LTD

Reference : 3.5"× 3.5"

Material : Stainless steel

Overall sizes

i. knuckle : 88.9 mm long × 11.2 mm diameter

ii. blades

: 88.9 mm long × 38 mm wide × 2 mm thick

Fixings

i. type : Countersunk head wood screws

ii. material : Steel

iii. size : 31 mm long × 4.8 mm diameter

iv. number off per blade : 4

v. maximum distance of fixing screws

from exposed face of door leaf : 19.5 mm

Bedding material

i. overall size

: 88.9 mm long × 38 mm wide × 2 mm thick

5.Latch

Manufacturer : Jiangmen oneder industrial co.,LTD

Reference : OD-ML001E

Material : Steel

Overall size

i. fore plate : 240 mm×24 mm

ii. strike plate : 205 mm×22 mm

Page 13: TEST REPORT On Behalf of Jiangmen oneder industrial Co.,LTD … resistencia al fuego manilla... · Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang,

EN 1634-1

Clause Requirement Test Result - Remark Verdict

Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China Tel.: +86-755-27454498, Email: [email protected]

Report No.: B-S171215807

Page 13 of 19

iii. casing : 172 mm high×86 mm wide×15.3 deep

iv. latch bolt : 26.8 mm×12.8 mm with 13 mm throw

v. lock bolt

: 34.8 mm×8.8 mm with 11 mm&21 mm

double throw

Latch force : Newton metres(Nm)

Operation of latch bolt : Disengaged

Operation of lock bolt : Disengaged

Fixing method : Screwed

Bedding material to casing

i. overall size : To suit casing × 1 mm thick

Bedding material to back of fore plate

i. overall size : To suit fore plate × 2 mm thick

Cylinder

i. manufacturer : Jiangmen oneder industrial co.,LTD

ii. reference : OD-LK108

iii. material : Brushed steel

iv. overall size

: 32.4 mm high×9.6 mm wide×16.8 mm

diameter ×80 mm long

Lever handles

i. manufacturer : Jiangmen oneder industrial co.,LTD

ii. reference : OD-TH101

iii. material : Stainless steel

iv. overall size

: 140 mm long×19 mm diameter with 60 mm

projection complete with 53 mm

diameter backing roses and 53 mm

diameter escutcheons with 10 mm

projection

Flush Bolts

Manufacturer : Jiangmen oneder industrial co.,LTD

Reference : OD-DB005SS

Material : Stainless Steel

Overall sizes

i. fore plate

: 203mm × 19mm

ii. Bolt : 11mm diameter

Fixing method : Screwed

Page 14: TEST REPORT On Behalf of Jiangmen oneder industrial Co.,LTD … resistencia al fuego manilla... · Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang,

EN 1634-1

Clause Requirement Test Result - Remark Verdict

Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China Tel.: +86-755-27454498, Email: [email protected]

Report No.: B-S171215807

Page 14 of 19

Page 15: TEST REPORT On Behalf of Jiangmen oneder industrial Co.,LTD … resistencia al fuego manilla... · Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang,

EN 1634-1

Clause Requirement Test Result - Remark Verdict

Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China Tel.: +86-755-27454498, Email: [email protected]

Report No.: B-S171215807

Page 15 of 19

Test photo

The exposed face of the doorset prior to the start of the test

The unexposed face of the doorset The unexposed face of the doorset

after a test duration of 30minutes after a test duration of 90minutes

Page 16: TEST REPORT On Behalf of Jiangmen oneder industrial Co.,LTD … resistencia al fuego manilla... · Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang,

EN 1634-1

Clause Requirement Test Result - Remark Verdict

Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China Tel.: +86-755-27454498, Email: [email protected]

Report No.: B-S171215807

Page 16 of 19

Temperature and Deflection data

Mean Furnace Temperature, Together With The Temperature/Time Relationship Specified In The

Standard

Time Mins

Specified Furnace Temperature

Deg.C

Actual Furnace Temperature

Deg.C

0 2 4 6 8

10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90

20 445 544 603 646 678 706 728 748 766 781 796 809 820 832 842 852 860 869 877 885 892 899 906 912 918 924 930 935 940 945 947 950 951 953 955 956 958 960 961 963 964 966 967 969 970

31 394 616 610 634 676 706 722 756 776 772 788 818 837 849 855 857 861 867 871 877 882 887 892 899 909 919 932 952 962 965 967 968 970 972 973 975 977 978 980 981 982 985 986 987 988

Page 17: TEST REPORT On Behalf of Jiangmen oneder industrial Co.,LTD … resistencia al fuego manilla... · Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang,

EN 1634-1

Clause Requirement Test Result - Remark Verdict

Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China Tel.: +86-755-27454498, Email: [email protected]

Report No.: B-S171215807

Page 17 of 19

Individual And Mean Temperatures Recorded On The Unexposed Surface Of The Doorset

Time

Mins

T/C Number

2 Deg.C

T/C Number

3 Deg.C

T/C Number

4 Deg.C

T/C Number

5 Deg.C

T/C Number

6 Deg.C

T/C Temp.

Deg.C

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90

20 20 20 20 20 20 20 21 22 23 24 26 27 29 30 32 34 36 38 40 43 46 49 53 57 59 61 66 70 73 63 64 66 68 71 72 74 75 77 79 81 80 82 85 87 89

19 19 19 19 19 19 20 20 21 22 23 24 25 26 28 30 31 34 36 38 41 43 46 49 53 57 52 53 67 62 67 65 68 69 70 71 73 74 76 78 79 80 82 84 86 88

20 20 22 23 23 22 22 23 25 26 28 30 32 33 35 37 39 41 43 45 47 50 53 55 58 61 57 58 60 65 71 72 73 74 74 75 76 79 82 86 89 92 94 95 97 98

20 20 20 20 20 20 21 21 23 24 26 27 29 30 32 34 36 38 40 42 44 46 49 52 55 57 60 64 67 70 73 73 74 75 76 77 78 79 80 81 82 84 84 86 88 90

20 20 20 20 20 20 21 21 22 23 24 25 27 28 30 31 33 36 38 40 43 45 48 51 54 57 60 64 67 70 73 74 74 75 76 78 79 80 81 82 83 84 85 86 88 89

20 20 20 20 20 20 21 21 23 24 25 26 28 29 31 33 35 37 39 41 44 46 49 52 55 58 58 61 64 68 69 71 72 74 76 76 77 78 79 80 81 82 83 85 87 89

Page 18: TEST REPORT On Behalf of Jiangmen oneder industrial Co.,LTD … resistencia al fuego manilla... · Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang,

EN 1634-1

Clause Requirement Test Result - Remark Verdict

Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China Tel.: +86-755-27454498, Email: [email protected]

Report No.: B-S171215807

Page 18 of 19

Individual Temperatures Recorded On The Unexposed Surface Of The Doorset

Time

Mins

T/C Number

7 Deg.C

T/C Number

8 Deg.C

T/C Number

9 Deg.C

T/C Number

10 Deg.C

T/C Number

11 Deg.C

T/C Temp.

12 Deg.C

0 2 4 6 8

10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90

20 21 22 23 23 22 23 23 26 28 30 32 33 34 36 38 40 42 44 47 49 52 55 59 65 71 68 72

117 87 88 89 90 91 92 94 96

102 108 121 125 123 121 125

118 108

22 22 23 24 24 24 25 26 29 31 33 35 37 39 39 40 41 43 45 46 48 51 53 56 69 83 64 60 59 59

137 128 115 113 108 103 106 121 122 128 146 131 128 119 117 115

22 22 24 25 25 25 25 28 30 33 36 39 41 43 45 47 49 51 53 55 57 60 63 67 72 55 51 51 52 62 63 65 66 67 69 71 72 73 75 77 78 79 81 83 85 88

22 22 22 22 22 22 22 25 28 31 33 36 38 41 33 45 47 49 51 53 55 57 60 63 67 69 70 71 68 57 59 62 64 65 67 69 70 71 73 74 76 77 79 81 82 84

22 22 22 22 22 22 22 22 23 24 25 26 26 28 29 31 33 35 37 40 43 46 49 53 56 60 64 68 72 63 57 58 60 61 63 64 65 68 70 71 72 75 78 79 82 85

22 22 25 24 24 25 26 27 29 30 33 35 37 40 42 45 47 49 52 54 55 58 60 62 65 63 56 58 63 69 70 76 78 79 82 85 92 96 97 99

103 106 108 117 112 109

Page 19: TEST REPORT On Behalf of Jiangmen oneder industrial Co.,LTD … resistencia al fuego manilla... · Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang,

EN 1634-1

Clause Requirement Test Result - Remark Verdict

Beide (SHENZHEN) Product Service Limited 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao’an Dist, Shenzhen, China Tel.: +86-755-27454498, Email: [email protected]

Report No.: B-S171215807

Page 19 of 19

Individual Temperatures Recorded On The Unexposed Surface Of Door Frame

...................................... END .........................................................

Time

Mins

T/C Number

13 Deg.C

T/C Number

14 Deg.C

T/C Number

15 Deg.C

T/C Number

17 Deg.C

T/C Number

18 Deg.C

T/C Number

19 Deg.C

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90

22 22 22 22 22 22 22 23 24 25 26 28 29 31 32 34 36 37 40 42 45 47 50 53 57 60 63 67 70 73 76 77 78 78 79 80 81 82 83 85 86 87 88 90 91 92

21 21 26 31 33 32 34 33 34 37 39 40 41 43 45 47 48 49 50 53 56 59 61 71 87

109 84 86

496 * * * * * * * * * * * * * * * * *

17 18 24 25 28 27 24 24 24 26 28 28 30 32 34 37 40 43 44 47 48 80

126 88 77 76 58

276 298 476

* * * * * * * * * * * * * * * *

16 16 16 16 16 16 19 24 27 28 28 30 34 37 39 38 39 40 41 43 44 45 46 47 48 48 50 50 52 54 53 51 53 54 55 57 58 58 59 60 61 62 64 64 65 66

17 17 17 17 17 17 17 17 19 21 24 25 27 29 31 32 33 32 32 30 28 25 23 22 22 23 22 23 23 24 24 25 25 26 27 27 28 29 29 30 31 32 34 33 33 35

17 18 18 18 18 18 18 19 20 22 24 27 30 33 35 37 39 40 41 42 43 45 47 49 60 76 58 55 57 65 88 71 73 75 77 79 80 81 82 84 85 83 79 77 75 71