the best patient safety choice today, and tomorrow€¦ · masimo america masimo europe masimo asia...

2
Masimo SET ® pulse oximetry: the original and best read-through motion and low perfusion pulse oximeter. 1,2 Clinically proven in over 100 independent clinical studies. Linked to improved care and reduced medical errors. 3,4,5 Optional Rainbow technology platform allows carboxyhemoglobin (SpCO ® ) and methemoglobin (SpMet TM ) measurements. Undiagnosed methemoglobin and carboxyhembglobin have been directly linked to increased morbidity and mortality. SpCO and SpMet parameters can be factory ordered or added in the field with a simple software upgrade. Rainbow technology allows expansion to future parameters as they are cleared for market. Enhanced probe-off detection with Rainbow sensors. Color display allows immediate differentiation of critical measurements. The best patient safety choice today, and tomorrow

Upload: others

Post on 17-Jun-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: The best patient safety choice today, and tomorrow€¦ · Masimo America Masimo Europe Masimo Asia Pacific tel +1 949 297 7000 tel +33 (0) 4 72 17 93 70 tel +65-9889-9389 fax +1

■ Masimo SET® pulse oximetry: the original and best read-through motion and low perfusion pulse oximeter.1,2 Clinically proven in over 100 independent clinical studies.

■ Linked to improved care and reduced medicalerrors.3,4,5

■ Optional Rainbow technology platform allows carboxyhemoglobin (SpCO®) and methemoglobin (SpMetTM) measurements.

■ Undiagnosed methemoglobin and carboxyhembglobin have been directly linked to increased morbidity and mortality.

■ SpCO and SpMet parameters can be factory ordered or added in the field with a simple software upgrade. Rainbow technology allows expansion to future parameters as theyare cleared for market.

■ Enhanced probe-off detection with Rainbowsensors.

■ Color display allows immediate differentiation ofcritical measurements.

The best patient safety choice today, and tomorrow

Page 2: The best patient safety choice today, and tomorrow€¦ · Masimo America Masimo Europe Masimo Asia Pacific tel +1 949 297 7000 tel +33 (0) 4 72 17 93 70 tel +65-9889-9389 fax +1

Specifications

performance*measurement range

SpO2: 0 - 100%SpMet: 0 - 99.9%SpCO: 0 - 99%Pulse Rate: 25 - 240 (bpm)Perfusion Index: 0.02% - 20%Pleth Variability Index: 0 - 100%

SpO2 accuracySaturation: 70% to 100%**

No MotionAdults, Pediatrics: ±2 digitsNeonates: ±3 digits

Motion 6

Adults, Pediatrics: ±3 digitsNeonates: ±3 digits

Low Perfusion 8

Adults, Pediatrics: ±2 digitsNeonates: ±3 digits

pulse rate accuracyPulse Rate: 25 - 240 bpm

No MotionAdults, Pediatrics, Neonates: ±3 digits

MotionAdults, Pediatrics, Neonates: ±5 digits

Low PerfusionAdults, Pediatrics, Neonates: ±3 digits

SpMet accuracy (1% - 15%)Methemoglobin Saturation Accuracy (%SpMet) +1 digits9

SpCO accuracy (1% - 40%)Carboxyhemoglobin Saturation Accuracy (%SpCO)*** +3 digits9

resolutionOxyhemogolobin Saturation (%SpO2): 1%Carboxyhemoglobin Saturation (%SpCO), digital display 1%Methemoglobin Saturation (%SpMet), digital display 0.1%Pulse Rate (bpm): 1 bpm

electricalstandalone

AC Power requirements: 100 - 240 VAC, 47 - 63 HzPower consumption: 55 VAFuses: 1 Amp, Fast Acting, Metric, (5x20mm), 250V

batteriesHandheld

Type: NiMHCapacity: 4 hours10

Charging time: 3 hoursStandalone (model RDS-1B only)

Type: NiMHCapacity: 10 hours10

Charging time: 6 hours

environmentalOperating Temperature: 41°F to 104°F (5°C to 40°C)Storage Temperature: -40°F to 158°F (-40°C to +70°C)Operating Humidity: 5% to 95%, non-condensingOperating Altitude: 500 mbar to 1060 mbar pressure,

-1000 ft to 18,000 ft (-304 m to 5,486 m)

physical characteristicsdimensionsHandheld: 8.9” x 3.5” x 2.1” (22.6 cm x 8.9 cm x 5.3 cm)Standalone: 3.5” x 10.5” x 7.7” (8.9 cm x 26.7 cm x 19.6cm)

weightHandheld: 1.2 lbs (0.54 kg)Docking Station (models RDS-1, 2, and 3): 2.5 lbs (1.14 kg)

(model RDS-1B): 3.1 lbs (1.41 kg)Standalone (models RDS-1, 2, and 3): 3.7 lbs (1.68 kg)

(model RDS-1B): 4.3 lbs (1.95 kg)

trendingProvides 72 hours of trending at 2 second resolution and up to 18 days at 10second resolution of SpO2, SpMet, SpCO, Pulse Rate, and Perfusion Indexwith output to serial printer or other serial devices.

SpO2 modesAveraging mode: 2, 4, 8,10,12,14 or 16 seconds 11

Sensitivity: Normal, APOD, and Maximum 12

alarmsAudible and visual alarms for high and low saturation (SpO2 1-100%, SpMet 0.1 - 100%, SpCO 1 - 100%, and pulse rate 25 - 240)

display/indicatorsData display: %SpO2, %SpMet, %SpCO, pulse rate,

pleth waveform, alarm status, trends, status messages,Signal IQ, perfusion index, MAX and APOD sensitivities and FastSat

Display Color BlackType: TFT Color LCDPixels: 480 x 272 dotsDot Pitch: 0.20 mm

output interfacePhilips Vuelink, Spacelabs Universal Flexport, RadNet TM (models RDS-1/1B,RDS-3)

Features

■ Masimo SET is clinically proven to be the highestsensitivity and specificity pulse oximeter in the world1,2

■ Rainbow technology uses 7+ wavelengths of light tocontinuously and noninvasively measurecarboxyhemoglobin (SpCO ®) and methemoglobin(SpMetTM), as well as providing the most reliableprobe-off detection

■ Perfusion Index (PI) with trending capability indicatesarterial pulse signal strength and may be used as adiagnostic tool during low perfusion7

■ Pleth Variability Index (PVI): captures vital thoracicpressure changes that may compromise normalcardiac function affecting systemic circulation

■ Accurate on cyanotic patients**

■ Signal IQ ® waveform for signal identification andquality indication during excessive motion and lowsignal to noise situations

■ FastSat ® tracks rapid changes in arterial O2 withhigh fidelity unlike any other pulse oximeter

■ Variable pitch provides tonal variance for every 1%change in saturation

■ SatShare® interface allows transfer of SpO2 andpulse rate to existing multiparameter monitor andallows for the reading of SpCO and SpMet onadjacent Radical-7 monitor

■ Automatic screen rotation provides upright displayfor vertical or horizontal monitor positioning (not available on the RDS-2 model)

■ Remote alarming interface

■ Up to eighteen days of trending

■ Detachable portable hand-held for patienttransport

3D Alarm System Option

■ Desat Index AlarmTM enables clinicians to detectan increasing quantity of smaller desaturationsthat may precede declining respiratory status

■ PI Delta AlarmTM alerts clinicians to specifiedchanges in perfusion, often a reliable indicator ofillness severity 7

* Specifications based on Masimo SET v7 software.** With LNOP-Blue Sensors on cyanotic patients. Accuracy from 60 - 100 +4 digits.*** When using a Masimo Rainbow reusable sensor.

References:1 Hay WW, Rodden DJ, Collins SM, Melera DL, Hale KA, Fashaw LM, Reliability of

conventional and new oximetry in neonatal patients. Journal of Perinatology.2002; 22:360-366.

2 Barker SJ. “Motion-resistant” pulse oximetry: a comparison of new and oldmodels. Anesthesia Analgesia 2002; 95:967-72.

3 Durbin CG, Rostow SK. Crit Care Med 2002;30(8):1735-1740.4 Chow LC, Wright KW, Sola A, and the SCMC Oxygen Admin Study Group.

Pediatrics 2003;111(2): 339-345.

Masimo America Masimo Europe Masimo Asia Pacifictel +1 949 297 7000 tel +33 (0) 4 72 17 93 70 tel +65-9889-9389fax +1 949 297 7001 fax +33 (0) 4 78 35 78 08

[email protected] [email protected] [email protected]

©2007 Masimo Corporation. Masimo, SET, APOD, , Accuratemonitoring when you need it most, Radical-7, APOD, FastSat, SignalIQ, SIQ, SatShare, SmartTone, RadNet, Desat Index Alarm, and PIDelta Alarm, Pulse CO-Oximeter are trademarks or registeredtrademarks of Masimo Corporation. Rainbow is a trademark ofMasimo Laboratories. All rights reserved.

5 Granelli AD, Mellander M,Sunnegardh J, Sandberg K,Ostman-Smith I. Acta Paediatrica2005;94:1590-1596.

6 Continuous rubbing and tappingmotions at 2 to 4 Hz at anamplitude of 1 to 2 cm andcontinuous random frequencymotion between 1 to 5 Hz at anamplitude of 2 to 3 cm

7 Defelice C, Latini G, Vacca P,Kapotic RJ, Eur J Pediatr2002;161:561-562.

8 Perfusion Index >0.02% and %Transmission > 5%

9 Accuracy has been validated onhealthy adult volunteers against alaboratory co-oximeter

10 When using a new, fully chargedbattery

11 With FastSat the averaging time isdependent on the input signal

12 Maximum Sensitivity modedisables APOD, but maximizesmeasuring ability

1-877-4-masimo www.masimo.com 40 Parker Irvine, CA 92618 U.S.A. 949.297.7000

7525

-437

5A-1

206

RDS-

1RD

S-2

RDS-

3

Automatic Display Rotation (Gravity Activated) Provides forvertical and horizontal positioning to maximize spaceutilization and visibility.

Motion Excessive Motion

Signal IQ

Pleth.Pleth.

Signal IQ

As the plethysmograph waveform gets corrupted with motion, the Signal IQ ® indicator shows the locationof the pulse, while the height of the vertical bar indicates the quality of the values displayed. When thesignal quality is compromised during excessive motion, a “Low Signal IQ” message is displayed.

Radical-7 Quick Trend feature allows for one-touch button access to parameter trendinginformation with the ability to adjust the trending data for specific patient conditions.