the centro nacional de aceleradores rafael garcia-tenorio vice-director c.n.a. ministerio de...

29
The Centro Nacional de Aceleradores RAFAEL GARCIA- TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

Upload: destiny-perez

Post on 27-Mar-2015

214 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

The Centro Nacional

de Aceleradores

RAFAEL GARCIA-TENORIO

VICE-DIRECTOR C.N.A.

MINISTERIO

DE EDUCACION Y CIENCIA

Page 2: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

Centro Nacional de Aceleradores

• Established as an agreement between the University of Sevilla, Junta de Andalucia and C.S.I.C. in 1997.

• A National facility open to national and international collaboration with:

- Other Universities and Health Care Centers (public, private).- Public Research Institutes.- Private companies.

A good environment for the training od scientists and technicians

ISO 27000 and ISO 9001 Certifications

Page 3: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

CNA building, Parque Tecnológico Cartuja 93 (former place of Australian Pavillion during World Exposition 1992))

Page 4: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

CNA Personnel (Sept. 2012)

• Staff (permanent, PhD): 9• Doctors (temp): 12• Post-Graduates (temp): 9• Administration: 3• Technicians: 9

• Total: 42

Page 5: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

CNA Personnel

Page 6: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

Institutional Agreements

-IAEA Collaboration Centre

-Collaboration with ENRESA (National Company in charge of the Nuclear Waste Mangement in Spain)

- Collaboration with CIEMAT.

- Collaboration with Virgen del Rocio Hospital

- Collaboration with ALTER Co. (irrdiation of aerospatial components)

- Collaboration with CSN (Spanish Nuclear Safety Council)

OPAC “Optimization of particle accelerators”Marie Curie ITN; partners: 10 institutions.

European Project

Page 7: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

Scientific Production

Summary 2007-2008 2009-2010

Finnanced Projects

35 46

Artícles ISI 68 107

Congress Contributions

69 99

Ph D Tesis + Master Works

2+4 2+6

Page 8: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

CNA General Information

2008 2012 Increment

Budget 1130 k€ 1172k€ 4%

Personnel 33 42 27%

Permanent Staff 5 10 100%

Turnover 65 k€ 128 k€ (2011)

97%

Big Installations 3 5+1 100%

Page 9: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

Scientific Objectives of CNA

• A Centre of Reference in material analysis through the application of IBA techniques.

• A Centre of Reference in AMS and in 14C dating• A Centre of Reference in the development of

radiation detectors instrumentation. • A Centre of Reference in Medical Image and in

Radiopharmaceutical syntheses.• A Centre of Reference in the development and

application of irradiation tests

To be….

Page 10: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

A Centre of Reference in material analysis through the application of IBA techniques.

Page 11: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

Spintronics applications

Study of defects after ion implantation of transition metals (Ni) in SiC monocristals for application in spin electronics

Collaboration: ICMM, MFA (Budapest); INSP (Paris); UNAM (Mexico)Ref: PSSc 5(2008)1374; NIMB 267(2009)1097

Page 12: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

Archaeometry studies using Archaeometry studies using external beamexternal beam

Large and non suitable for vacuum samples Large and non suitable for vacuum samples can be analyzed with the external beamcan be analyzed with the external beam

Page 13: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

Micro-probe μ-PIXE

Hot-particle Analysis

Pu (L)

Pu (L)

U (L)

U (L)

A15 Scan 100x100 m2

HP3 Scan 75x75 m2

Pu and U concentration maps in hot particles with origin in the Palomares nuclear accident. Both elements are confined inside the particle.

Page 14: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

A Centre of Reference in AMS and in 14C dating

Page 15: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

14C: Bomb pulse effect in Mexico

-100

0

100

200

300

400

500

600

700

800

900

1948 1958 1968 1978 1988 1998 2008

D14

C (‰

)México

NH zone 2 (Hua and Barbetti, 2004)

NH zone 3 (Hua and Barbetti, 2004)

Niwot Rich, Colorado, clean air(Turnbull et al., 2007)

Jungfraujoch, clean air (Levin andKromer, 2004)

Page 16: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

Effect of Nuclear release of 129I in the Baltic and North Sea

J. Environ. Radioact., 1992, 15, 231

Algae from the coast of Sweden in the North and the Baltic Sea

North Sea is much more affected by the releases of Sellafield and La Hague. No exchange with the Baltic Sea.

Page 17: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

Plutonium isotopes in air filter samples(Seville)

Seasonal trend (high values in summer).

They were correlated with Saharan Dust Intrusion

Page 18: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

A Centre of Reference in the development of radiation detectors instrumentation

Page 19: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

Tracking detectors

(CNA-Saclay-GANIL) Collaboration

Page 20: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

Characterization of a strip Si detector for Radiotherapy dosis measurement

U.Sevilla-CNA-INABENSA-HUVM-ESII

Si strip detector inside a cilindrical phantom

Measurement with a clinical electron accelerator

PATENT SUBMITTED

Page 21: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

Neutron line @ CNA: astrophysics

Performed two different activations that should correspond to measure the Maxwellian Average Cross Section (MACS) of 181Ta at kT=30 keV and kT=55 keV by using MACS of Au as reference.

The MACS is the fundamental ingredient for the calculation of the reaction rates of the elements with A>56 in the Universe.

EXPERIMENTAL SETUP AT CNAChamber designed, constructed and tested at LNL-INFN.Copper backing developed at Seville. Water cooling flowing around. Lithium foil.

Page 22: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

A Centre of Reference in Medical Image and in Radiopharmaceutical syntheses.

Page 23: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

Some molecules prepared at CNA

• Na[18F]F for osseous and renal studies

O

N

N

O

O

Boc

OODMTrNos

O

N

NH

O

O

OH

F18

1) [18F]F/CH3CN

2) HCl

[18F]FLT

[18F]FLT as a cellular growth marker to obtain images for cancer diagnosis

For pre-clinic research the following radio-pharmaceuticals are produced in CNA: FLT, FMISO, BF4, NaF y 11C-metionina

Page 24: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

Cerebral Metabolism: Hipoxia-Ischemia

• Brain is pressed by a Fogarty balloon, and effects are monitored with FDG-PET and F-MISO images

Project developed in collaboration with the Pediatric Neurosurgery Unit of the Hospital Virgen del Rocío.

Fogarty balloon

PtiO2 sensor

Page 25: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

A Centre of Reference in the development and application of irradiations tests

Page 26: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

Radiation hardness in fibre optics sensors Radiation hardness in fibre optics sensors used in particle-physics experimentsused in particle-physics experiments

In a first experiment it was determined the existence of a relation between the type of coating of the sensor and its response under irradiation of protons.

In un second experiment it has been analyzed the effect of the protonic radiation in the response of nude sensors (withgout coating).

(Detectors from “Large Hadron Collider”-(Detectors from “Large Hadron Collider”-CERN)CERN)

Collaboration IFCA - CNA

Page 27: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

Response of luminiscent materials to ionic radiation

Reactors of Losses (escaping)

Fusion of fast ions

Diagnosis Luminiscence in

scintillators (ZnS(Ag))

Luminosity Afterglow

Detectors for plasma in ITER

Page 28: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA

Creation of a Service for irradiation of aeroespatial components

Irradiation of electronic circuits(total dose and SEE)

Irradiation of solar cells

Page 29: The Centro Nacional de Aceleradores RAFAEL GARCIA-TENORIO VICE-DIRECTOR C.N.A. MINISTERIO DE EDUCACION Y CIENCIA