the pump is designed to suck sea water from intake to ... · web viewthe pump is designed to suck...
TRANSCRIPT
![Page 1: The pump is designed to suck sea water from Intake to ... · Web viewThe pump is designed to suck sea water from Intake to condenser. Since start ing service in 2014, vibration of](https://reader036.vdocument.in/reader036/viewer/2022062509/6101db414f59fe2d4d2142c9/html5/thumbnails/1.jpg)
Equipment: Circulating Water Pump 1BLocation: CommonPump Specifications Motor SpecificationsType: Vertical Manufacturer: HyundaiNo. of blade 5 Power: 3300 kWModel: Speed: 295 rpmCapacity: 45280 m3/h Voltage: 11000 VTotal Head: 22.37 m Phase: 3
Poles: 20Frequency: 50 Hz
Point SymbolMotor outboard M1Motor inboard M2Shaft vibration SThrust bearing axial vibration Z
The pump is designed to suck sea water from Intake to condenser.
1
M1
M2
S
Z
![Page 2: The pump is designed to suck sea water from Intake to ... · Web viewThe pump is designed to suck sea water from Intake to condenser. Since start ing service in 2014, vibration of](https://reader036.vdocument.in/reader036/viewer/2022062509/6101db414f59fe2d4d2142c9/html5/thumbnails/2.jpg)
Since starting service in 2014, vibration of motor gradually increase after each low tide event (suction pressure reduces 2 times per months).
- In Apr 2016, the motor vibration is maximum 5mm/s when suction level is 6.5m
- In 2018 and 2019, the pump is trip by vibration at NDE motor 1 times, and many time peak to 7.1mm/s, but not trip due to delay in logic
2
![Page 3: The pump is designed to suck sea water from Intake to ... · Web viewThe pump is designed to suck sea water from Intake to condenser. Since start ing service in 2014, vibration of](https://reader036.vdocument.in/reader036/viewer/2022062509/6101db414f59fe2d4d2142c9/html5/thumbnails/3.jpg)
Data collected by CSI 2600 vibration analyzer, from port of the Pump’s vibration monitoring system
At normal tide level (7m)o Motor NDE side: dominant peak at 2X
3
![Page 4: The pump is designed to suck sea water from Intake to ... · Web viewThe pump is designed to suck sea water from Intake to condenser. Since start ing service in 2014, vibration of](https://reader036.vdocument.in/reader036/viewer/2022062509/6101db414f59fe2d4d2142c9/html5/thumbnails/4.jpg)
o Motor DE side: also dominant peak at 2X, and some peak around 140Hz (which is not appear when collect data by portable analyzer)
4
![Page 5: The pump is designed to suck sea water from Intake to ... · Web viewThe pump is designed to suck sea water from Intake to condenser. Since start ing service in 2014, vibration of](https://reader036.vdocument.in/reader036/viewer/2022062509/6101db414f59fe2d4d2142c9/html5/thumbnails/5.jpg)
o Shaft vibration: dominant peak at 1X, 2X peak appear
5
![Page 6: The pump is designed to suck sea water from Intake to ... · Web viewThe pump is designed to suck sea water from Intake to condenser. Since start ing service in 2014, vibration of](https://reader036.vdocument.in/reader036/viewer/2022062509/6101db414f59fe2d4d2142c9/html5/thumbnails/6.jpg)
o Axial vibration at thrush bearing: peak at 5x with noise floor raises
6
![Page 7: The pump is designed to suck sea water from Intake to ... · Web viewThe pump is designed to suck sea water from Intake to condenser. Since start ing service in 2014, vibration of](https://reader036.vdocument.in/reader036/viewer/2022062509/6101db414f59fe2d4d2142c9/html5/thumbnails/7.jpg)
At low tide level (6.4m)o Motor NDE side: vibration level is much higher than normal tide, but dominant
peak still 2X
7
![Page 8: The pump is designed to suck sea water from Intake to ... · Web viewThe pump is designed to suck sea water from Intake to condenser. Since start ing service in 2014, vibration of](https://reader036.vdocument.in/reader036/viewer/2022062509/6101db414f59fe2d4d2142c9/html5/thumbnails/8.jpg)
o Motor DE side: same situation as NDE side, but amplitude does not increase as much as NDE
8
![Page 9: The pump is designed to suck sea water from Intake to ... · Web viewThe pump is designed to suck sea water from Intake to condenser. Since start ing service in 2014, vibration of](https://reader036.vdocument.in/reader036/viewer/2022062509/6101db414f59fe2d4d2142c9/html5/thumbnails/9.jpg)
o Shaft vibration: does not change much compare with normal tide
9
![Page 10: The pump is designed to suck sea water from Intake to ... · Web viewThe pump is designed to suck sea water from Intake to condenser. Since start ing service in 2014, vibration of](https://reader036.vdocument.in/reader036/viewer/2022062509/6101db414f59fe2d4d2142c9/html5/thumbnails/10.jpg)
o Axial vibration at thrush bearing
10