thermal bypass checklist round-table thermal bypass checklist round-table

23
Thermal Bypass Thermal Bypass Checklist Checklist Round-Table Round-Table

Upload: alexis-hahn

Post on 27-Mar-2015

230 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

Thermal Bypass Thermal Bypass Checklist Checklist

Round-TableRound-Table

Page 2: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

WHAT IS THERMAL BYPASS?WHAT IS THERMAL BYPASS?

7070o o FF

7070o o FF

3030o o FF

5050o o FF

Page 3: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

WHAT THERMAL BYPASS LOOKS LIKEWHAT THERMAL BYPASS LOOKS LIKE

Page 4: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

GENERALGENERAL

Builder not required to sign Builder not required to sign checklist if he/she has not checklist if he/she has not verified any items.verified any items.

Maximum of four items allowed Maximum of four items allowed for builder refers to numbered for builder refers to numbered items, not bullets. items, not bullets.

Page 5: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

THERMAL BYPASS CHECKLIST: THERMAL BYPASS CHECKLIST:

1. INSULATION ALIGNMENT1. INSULATION ALIGNMENT

Insulated Insulated sloped sloped ceilings:ceilings: Air barrier Air barrier required required except if except if closed cell closed cell spray foamspray foam

Page 6: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

THERMAL BYPASS CHECKLIST: THERMAL BYPASS CHECKLIST:

1. INSULATION ALIGNMENT1. INSULATION ALIGNMENT

Doors to Doors to unconditioned unconditioned spaces shall meet spaces shall meet IECC insulation IECC insulation requirements for requirements for exterior doors and exterior doors and include full include full weatherstripping.weatherstripping.

Page 7: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

THERMAL BYPASS CHECKLIST:THERMAL BYPASS CHECKLIST: 1. INSULATION ALIGNMENT1. INSULATION ALIGNMENT

Slab Edge Insulation:Slab Edge Insulation:(Climate Zones 4 and higher)(Climate Zones 4 and higher)

InteriorInteriorExteriorExterior

Plan for Flooring!!!Plan for Flooring!!!

Page 8: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

Band Joists:Band Joists:

Highly encourageHighly encourage,, but don’t require complete air barrier detail but don’t require complete air barrier detail

except:except:– Garage/House Interface (Item #1)Garage/House Interface (Item #1)– Cantilevered Floor (Item #6) Cantilevered Floor (Item #6) – Porch Roof (Item #12)Porch Roof (Item #12)

THERMAL BYPASS CHECKLIST:THERMAL BYPASS CHECKLIST: 1. INSULATION ALIGNMENT1. INSULATION ALIGNMENT

Page 9: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

THERMAL BYPASS CHECKLIST:THERMAL BYPASS CHECKLIST: 2. SHOWER/TUB EXTERIOR WALL2. SHOWER/TUB EXTERIOR WALL

Page 10: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

THERMAL BYPASS CHECKLIST: THERMAL BYPASS CHECKLIST:

3. INSULATED FLOOR OVER 3. INSULATED FLOOR OVER GARAGEGARAGE

Improper Improper insulation! insulation! It must touch It must touch the surface it the surface it is intended to is intended to insulate. insulate. Critical to Critical to check for air check for air gap!gap!

Page 11: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

THERMAL BYPASS CHECKLIST:THERMAL BYPASS CHECKLIST: 4. WALLS ADJOINING UNCOND. SPACES4. WALLS ADJOINING UNCOND. SPACES

Key Areas:Key Areas: Attic Knee WallsAttic Knee Walls Double WallsDouble Walls Skylight ShaftsSkylight Shafts Porches (TBC # 14)Porches (TBC # 14)

Page 12: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

THERMAL BYPASS CHECKLIST:THERMAL BYPASS CHECKLIST: 4. WALLS ADJOINING UNCOND. SPACES4. WALLS ADJOINING UNCOND. SPACES

Double WallsDouble Walls

Air BarrierAir Barrier

HeaHeatt

Page 13: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

THERMAL BYPASS CHECKLIST:THERMAL BYPASS CHECKLIST: 4. WALLS ADJOINING UNCOND. SPACES4. WALLS ADJOINING UNCOND. SPACES

Courtesy of Consol Courtesy of Consol

Page 14: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

THERMAL BYPASS CHECKLIST:THERMAL BYPASS CHECKLIST: 4. WALLS ADJOINING UNCOND. SPACES4. WALLS ADJOINING UNCOND. SPACES

Courtesy of Consol Courtesy of Consol

Page 15: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

THERMAL BYPASS CHECKLIST:THERMAL BYPASS CHECKLIST: 4. WALLS ADJOINING UNCOND. SPACES4. WALLS ADJOINING UNCOND. SPACES

Courtesy of Consol Courtesy of Consol

Page 16: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

THERMAL BYPASS CHECKLIST: THERMAL BYPASS CHECKLIST:

4. WALLS ADJOINING UNCOND. SPACES4. WALLS ADJOINING UNCOND. SPACES

SkylightSkylight

Air BarrierAir Barrier Air BarrierAir Barrier

AtticAttic

InsulatiInsulationon

Skylight ShaftSkylight Shaft

Page 17: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

THERMAL BYPASS CHECKLIST:THERMAL BYPASS CHECKLIST:

4. WALLS ADJOINING UNCOND. SPACES4. WALLS ADJOINING UNCOND. SPACES

14”14”

Exposed area = ~30 sq.ft.Exposed area = ~30 sq.ft.Need insulation and air barrier Need insulation and air barrier

Tubular SkylightTubular Skylight

Page 18: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

THERMAL BYPASS CHECKLIST:THERMAL BYPASS CHECKLIST: 6. CANTILEVERED FLOOR6. CANTILEVERED FLOOR

Thermal Thermal BypassBypass

Thermal Thermal BypassBypass

Tips:Tips:Consider spray Consider spray foam insulation foam insulation installed to installed to desired thickness desired thickness because it can because it can serve as both serve as both insulation and an insulation and an air barrier.air barrier.Critical to Critical to check air gap check air gap at floor.at floor.

Seal EdgesSeal Edges

Fill withFill withInsulationInsulation

AddAddBlockingBlocking

Page 19: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

THERMAL BYPASS CHECKLIST:THERMAL BYPASS CHECKLIST:

8. FLUE SHAFT8. FLUE SHAFT

Image courtesy of EnergyLogic

TIP:TIP:Specially Specially

colored fire-colored fire-rated foam now rated foam now

available for available for sealing difficult sealing difficult air gaps at flue air gaps at flue

openingsopenings

Page 20: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

THERMAL BYPASS CHECKLIST: THERMAL BYPASS CHECKLIST:

11. FIREPLACE SHAFT WALL11. FIREPLACE SHAFT WALL

Page 21: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

WRAP-UPWRAP-UP

Any other concerns?Any other concerns?

Page 22: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

ANSWER...ANSWER...

One more thought…One more thought…

““It wasn’t raining It wasn’t raining when Noah built when Noah built the Ark.”the Ark.”

Howard DuffHoward Duff

Page 23: Thermal Bypass Checklist Round-Table Thermal Bypass Checklist Round-Table

HOW TO GET MORE INFORMATIONHOW TO GET MORE INFORMATION

On the Web at:http://www.energystar.gov/homeshttp://www.energystar.gov/homes