thermal insulation system - sia polfix insulation.pdf · thermal insulation system 4masterplast...

20
THERMAL INSULATION SYSTEM

Upload: dangthien

Post on 04-Jun-2018

252 views

Category:

Documents


0 download

TRANSCRIPT

THERMAL INSULATION SYSTEM

THERMAL INSULATION SYSTEMMASTERPLAST GROUP INTERNATIONAL2

THERMAL INSULATION SYSTEM GENERAL DESCRIPTION OF THE SYSTEM

This short description introduces the Thermomaster external thermal insulation composite system and its components. This product catalogue and THERMOMASTER® Instruction Guidline issued by MASTERPLAST GROUP provide more detailed information about the system.

Components and structure of the THERMOMASTER® A02 EPS system:

Components and structure of the THERMOMASTER® rock wool system:

Before the start of construction works, the building must be examined: the material and the thickness of the wall, the potential thermal bridges and their positions, the quality and moisture content of the surface (underground), as well as the quality and the thickness of the existing plaster layer.

1. THERMOMASTER® Socle profile 2. MASTERFIX® PRO or FALFIX Plus adhesive - 2.5–4 kg/m2

3. ISOMASTER® EPS H 80 thermal insulation 4. Anchor (when required) 5. Corner bead with mesh 6. MASTERFIX® PRO or FALFIX base coat 3–3.5 kg/m2

7. MASTERNET® fiberglass mesh 1.1m2/m2

8. MASTERFIX® PRO or FALFIX base coat 9. CORATREND® 1.6–2 dl/m2

10. CORATREND® finishing layer 2.3–3 kg/m2

11. embossed XPS insulation12. CORAMIX marble plaster 4–5 kg/m2

11.

1.

5.3.

2.

4.

12.

10.

9.

8.

7.

6.

1. THERMOMASTER® socle profile 2. MASTERFIX® ROCK adhesive 4-5 kg/m2

3. NOBASIL FKD stone wool thermal insulation 4. Anchor (when required) 5. Corner bead with mesh 6. MASTERFIX® ROCK base coat 6–7 kg/m2

7. MASTERNET fiberglass mesh 1.1 m2/m2

8. MASTERFIX® ROCK base coat 9. Coramix key coat 2–3 dl/m2 10. Coramix silicone finishing coat 2.3–3 kg/m2

11. embossed XPS insulation12. CORAMIX marble plaster 4–5 kg/m2

11. 1.

5.

3.2.

4.

12.

10.

9. 8.

7. 6.

THERMAL INSULATION SYSTEM3MASTERPLAST GROUP INTERNATIONAL

Depending on the material and thickness of the wall, the following insulation thickness are recommended to be observed (for apartments or offices):

Material ISOMASTER® U value (W/m2K) Improvement of the insulation EPS 80 achieved with the ability of the structure achieved Insulation THER MO MAS TER® the THERMOMASTER®

thickness system system

Small-sized solid brick (25 cm) 8 cm 0.39 79% Small-sized solid brick (38 cm) 8 cm 0.38 74% Reinforced-concrete wall, (20 cm) 9 cm 0.38 87% Panel building 6 cm 0.37 58% Hollow brick (B30 – 30cm) 8 cm 0.37 75% Modern hollow brick (30 cm) 7* cm 0.29 60% Porous concrete (30 cm) 4* cm 0.31 53%

*in case of walls mentioned above, application of the thicker insulation than required is necessary in considerations of risk of vapour condensation. In bathrooms and wet spaces the internal surface of the walls must be tiled up to the ceiling, and only silicone finishing coat can be applied outside (for more details see: THERMOMASTER® Instruction Guidline).

Recommendations for the application of the system:The wall must be free of loose plasters, particles and paints, if necessary, the surface unevenness can be repaired by cement plaster. In case of strongly absorbing wall (e.g. porenbeton), it is recommended to use MASTERFIX® PRIMER). First step is the fixing of the socle profile by hammer fixed expansion plug (4 pcs/m), minimum 30 cm above the level of ground or pavement. The unevenness of the wall can be equalised with levelling pieces, the lengthening of the socle profile is with profile connector . The temperature of air must be over (+)5 C during the adhesion of ISOMASTER® EPS boards. The adhesive material could happen with MASTERFIX® PRO or FALFIX Plus. The dry material is mixed with water as specified on the packaging and mixed again after 2–3 minutes of rest. The mixed adhesive should be used within 20–30 minutes depending on the ambient temperature, but dilution of it after mixing is not allowed. The adhesive should be applied alongside, around as well as in 2-3 spots on the surface of the insulting sheets, (do not apply the bonding material onto the edges of the board). The bonded surface is min 30% of the tight-jointed ISOMASTER® EPS board, the thickness of the adhesive should be 0.5–2.0 cm. After setting of the adhesive (minimum 1–2 days, depending on the temperature), the following step is the eliminating of the surface unevenness and anchoring. If the height of the fa ade is less than 8 m, anchoring is only necessary, when the bonded surface were critical (e.g. plastered, painted, strongly absorbing). Over 8 meter building height, supplementary anchoring is always important, 4 – 8 –12 pcs/m2 is recommended, depending on the type of anchor, material of the wall and the building height (for more details see: THERMOMASTER® Instruction Guidline). The respective anchoring depths must be always observed, and kept (e.g. in consideration of the thickness of existing plastering).The application of the corner profiles happens before applying of the base coat and fiberglass mesh. This working process is sensitive to weather conditions, the ideal ambient and surface temperature is (+)5 – (+)25 °C. During the setting of the base coat (depending on weather but minimum 1–3 days), the temperature is not allowed to sink under (+)5°C, in case of too warm (over (+)25 °C) or windy weather, supplementary precautions must be made. For base coating MASTERFIX® PRO or FALFIX Plus are also applicable. The adequately mixed material must be used within 20–30 minutes. The mate-rial (~3 kg/m in the first layer) is applied onto the ISOMASTER® EPS surface by a notched trowel, then the fiberglass mesh must be embedded with 10 cm overlapping. The second layer of base coat requires only ~1.5 kg/m2 material.A thin key coat (CORATREND Primer or Coramix Primer) is necessary after setting of the base coat, which is intended to act as a preparation for the application of the finishing coat. Before applying the finishing coat, the primer must be com-pletely dried. The top coat (Coratrend or Coramix) can be made of acrylic or silicon dispersion. A considerable advantage of silicone dispersion, that its vapour transmission and water-repellent ability is better. Floated and ribbed structure with particle size of 1.5 mm and 2 mm can be chosen. When choosing the colour of the finishing coat, it mustb considered, that the same colour of look differently on big surface than on the colour patterns.

THERMAL INSULATION SYSTEMMASTERPLAST GROUP INTERNATIONAL4

Before the colouring works, the following tasks must be performed:• on a façade, only material made of the same production charge (indicated on label) can be used, otherwise the materials

derived from different charges must be mixed. • the plaster deposited on the cover of the bucket must be scraped back into the bucket. • CORATREND® render can be diluted with maximum 0.5 – 2.5 dl of water / bucket, depending on the weather conditions,

the amount of added pigment and the absorption capacity of the base coat. For every bucket the same quantity of water must be added, then mixed evenly, but the dilution extends the setting time on the wall, especially when the vapour content of the air is high.

Applying of CORATREND® top coat is also very sensitive to weather, warm and windy weather is not suitable for high quality work. The optimal temperature is about (+)15 - (+)25 °C. Between (+)25 - (+)30 °C, colouring could happen only on shaded surface. Cold weather (below 10 °C) and the high vapour content (over 75%) is not proper. Fresh top coat should be protected from wind, intensive UV radiation freezing and rain. For the insulation of the socle part of the building, XPS thermal insulation can be used, the bonding and coating happens on similar way, but the finishing layer is CORAMIX marble plaster.

Store vertically

To be kept indoors, in a dry place, protected from rain

Protected from sun and radiating heat

Product Description

Technical and Safety Data Sheet

CE certificate

Frost hazard

Expiry date: 1 year from production

Icons

THERMAL INSULATION SYSTEM5MASTERPLAST GROUP INTERNATIONAL

Material: alkaliresistant fiberglassApplication: Strenghtening mesh for Thermomaster® external thermal insulation sys-tem and reinforcement of internal cement plaster and plastic waterproofing.Quantity: 1.1 m2/net m2

Types: 125, 145, and 160 g/m2

Tensile strength after ageing: (MD/XD) MASTERNET® PREMIUM R-96 (125g) = 1100/900 N/5 cm MASTERNET® PREMIUM R-117 (145g) = 1500/1200 N/5 cm MASTERNET® PREMIUM R-131 (160g) = 1500/1500 N/5 cmRelevant specifications: Mastermesh 145 and 160 comply with the requirements of ETAG 004 and EN 13499.

Type of mesh Roll size Code

MASTERNET® PREMIUM R-96 (125 g) 1.1 m×50 fm=55 m2 0101-096WH055MASTERNET® PREMIUM R-117 (145 g) 1.1 m×50 fm=55 m2 0101-117WH055MASTERNET® PREMIUM R-131 (160 g) 1.1 m×50 fm=55 m2 0101-131WH055

PREMIUM fibreglass mesh

Material: alkaliresistant fiberglassApplication: Strenghtening mesh for Thermomaster® external thermal insulation system and reinforcement of internal cement plaster and plastic waterproofing.Quantity: 1.1 m2/net m2

Types: 125, 145, and 160 g/m2

Tensile strength after ageing (MD/XD) MASTERNET® A-125 = 800/1050 N/5 cm MASTERNET® A-145 = 1100/1450 N/5 cm MASTERNET® A-160 = 1250/1800 N/5 cmRelevant specifications: Mastermesh 145 and 160 comply with the requirements of ETAG 004.

Type of mesh Roll size Code

MASTERNET® A-125 1m×50 fm=50 m2 0102-125WH000

MASTERNET® A-145 1m×50 fm=50 m2 0102-145WH000

MASTERNET® A-160 1m×50 fm=50 m2 0102-160WH000

fibreglass mesh

THERMAL INSULATION SYSTEM6MASTERPLAST GROUP INTERNATIONAL

Material: expanded polystyreneApplication: Thermal insulation of external thermal insulation systems, covered with proper finishing coat (e.g. acrylic or silicone rendering).Quantity: 1.02 m2/net m2

Designation: EPS EN 13163 T2-L2-W2-S2-P4-BS125-CS(10)80-DS(N)2-DS(70)1-TR150Compression strength: 80 kPa Marking: red lineReaction to fire: Euroclasse: E (according to EN 13501-1)Relevant specifications: EN 13163 and EN 13499

Width Available Code

2 cm 0,24 m3/bale, 24 pcs/bale 0501-08002000

3 cm 0,24 m3/bale, 16 pcs/bale 0501-08003000

4 cm 0,24 m3/bale, 12 pcs/bale 0501-08004000

5 cm 0,25 m3/bale, 10 pcs/bale 0501-08005000

6 cm 0,24 m3/bale, 8 pcs/bale 0501-08006000

7 cm 0,245 m3/bale, 7 pcs/bale 0501-08007000

8 cm 0,24 m3/bale, 6 pcs/bale 0501-08008000

10 cm 0,25 m3/bale, 5 pcs/bale 0501-08010000

12 cm 0,24 m3/bale, 4 pcs/bale 0501-08012000

Other thickness with special delivery date for order

Material: water-repellent insulation, made of synthetic resin bonded mineral wool fibres. Field of application: Thermal, sound and fire-resistant insulation of external thermal insula-tion systems, covered with proper finishing coat (e.g. silicone rendering).Designation: MW-EN 13162 -T5 - DS(TH) - CS(10)40 - TR15 – WS - WL(P) - MU1,4 Density: 20-50 mm, 150 kg/m2, 60-160 mm, 140 kg/m2 Declared thermal conductivity (λD): 0.039 W/mK. Reaction to fire: A1 Compression strength (10%): 40 kPa (40 –160 mm) Tearing strength (perpendicular to faces): 15 kPa (40 –160 mm) Water vapour resistance factor (μ): 1.4 Size of board: 600 × 1000 mm

Width Available Code

NOBASIL FKD 2 cm 7.2 m2 0519-FKD02000

NOBASIL FKD 5 cm 3 m2 0519-FKD05000

NOBASIL FKD 6 cm 2.4 m2 0519-FKD06000

NOBASIL FKD 8 cm 1.8 m2 0519-FKD08000

NOBASIL FKD 10 cm 1.8 m2 0519-FKD10000

Only for order

EPS H-80

NOBASIL FKD (TF) stone wool thermal insulation

THERMAL INSULATION SYSTEM7MASTERPLAST GROUP INTERNATIONAL

Material: embossed extruded polystyrene with flat edge profileApplication: thermal insulation of external thermal insulation systems, even at surfaces exposed to wetness (e.g.: by socle)Quantity: 1.02 m2/net m2

Designation: XPS EN 13164 T1-CS(10/Y)200-DS(TH)-DLT(2)5-CC(2/1.5/50)100-MU200-TR200Compression strength: 200-300 kPa Reaction to fire: Euroclasse: E (according to EN 13501-1)Relevant specifications: EN 13164 and EN 13499

Width Available Code

2 cm 0.300 m3/bale, 20 pcs/bale 0510-28002000

3 cm 0.315 m3/bale, 14 pcs/bale 0510-28003000

4 cm 0.300 m3/bale, 10 pcs/bale 0510-28004000

5 cm 0.300 m3/bale, 8 pcs/bale 0510-28005000

6 cm 0.315 m3/bale, 7 pcs/bale 0510-28006000

8 cm 0.300 m3/bale, 5 pcs/bale 0510-28008000

10 cm 0.300 m3/bale, 4 pcs/bale 0510-28010000

12 cm 0.360 m3/bale, 4 pcs/bale 0510-28012000

2800 CStyrodur®

Material: ready to use liquid dispersion Application: very thin key coat which may be applied to the base coat and is intended to act as a preparation for the application of the finishing coat. It also can be used as a general primer.Coverage: 1–1.5 dl/m2 of the concentrated primerDilution: depending on the water-absorbing ability of the base coat or surface (maximum in the ratio of: 1 part of primer : 3 part of water)Temperature during application: (+)5 – (+)25°C (above (+)25°C it’s need additional measure)Drying time: 2–6 hours

Available Code

1 litre can 0103-10001001

5 litre can 0103-10001005

PRO adhesive and base coat render

Material: cement-bonding adhesive mortar with synthetic resin additive Application: it is used for the fixing of the insulation product (e.g. EPS, XPS) to the wall or applied directly onto the insulation product for the embedding of the fiberglass mesh - this layer provides most of the mechanical properties of the rendering. Coverage: as an adhesive: 2.5–4 kg/m2, as a base coat: 3 kg/m2 (in first layer)Application temperature: (+)5 – (+)25°C (above (+)25°C it’s need additional measure)Bond strength: 120kPa to EPS boardsApplicable: within 20 minutes after mixingRelated regulations: ETAG 004, EN 13499, EN 13499

Available Code

25 kg bag (1050 kg/palette) 0103-01111025

PRIMER

THERMAL INSULATION SYSTEM8 MASTERPLAST GROUP INTERNATIONAL

Material: cement-bonding adhesive mortar with synthetic resin additive and high vapour transmission ability.Application: it is used for the fixing of the stone-wool insulation (e.g. Nobasil FKD) to the wall or applied directly onto the insulation product for the embedding of the fiberglass mesh - this layer provides most of the mechanical properties of the rendering. Coverage: as an adhesive for total surface of the insulation (so-called lamell wool): 7-9 kg/m2, for ~40% partial surface fixing: ~4-5 kg/m2, as a base coat: ~6 kg/m2 (in first layer)Application temperature: (+)5 – (+)25°C (above (+)25°C it’s need additional measure)Applicable: within 20 minutes after mixingRelated regulations: ETAG 004, EN 13499

Available Code

25 kg bag (1050 kg/pallets) 0103-01201025

adhesive and base coat render

Material: cement-bonding adhesive mortar with synthetic resin additive Application: it is used for the fixing of the insulation product (e.g. EPS, XPS) to the wall or applied directly onto the insulation product for the embedding of the fiberglass mesh – this layer provides most of the mechanical properties of the rendering. Coverage: as an adhesive: 2.5–4 kg/m2, as a base coat: 3 kg/m2 (in first layer)Application temperature: (+)5 – (+)25°C (above (+)25°C it’s need additional measure)Bond strength: 150 kPa to EPS boardsApplicable: within 30 minutes after mixingRelated regulations: ETAG 004, EN 13499

Available Code

25 kg bag (1000 kg/palette) 0103-03001025

Material: ready to use liquid, mixture of pigments and fillers dispersed in water acrilyc dispersion with additives Application: very thin key coat, which may be applied to the base coat and is intended to act as a preparation for the application of the finishing coat Coratrend.Coverage: 1.6–2 dl/m2 Dilution: depending on the water-absorbing ability of the base coat or surface (maximum in the ratio of: 2 part of primer : 1 part of water)Temperature during application: (+)5 – (+)25 °C (above (+)25 °C it’s need additional measure)Drying time: 2–6 hoursStorage, expiry date: under dry conditions, protected against atmospheric exposure, especially sun-ra-diation and other heat sources. Storing temperature is between (+)5 °C and (+)25 °C. In case of the pre-scribed storage and handling conditions, the expiry date of the product is 18 months after production.

Available Code:

in buckets of 8 and 16 litres 0179-0…….

primer

THERMAL INSULATION SYSTEM9MASTERPLAST GROUP INTERNATIONAL

Material: ready to use paste, mixture of aggregates, pigments and fillers dispersed in copolymer of styreneacrylic dispersion with additives.Properties: the dried coat is flexible, durable, UV-resistant with good water-repellent ability.Application: it is applied to the base coat as a top coat of Thermomaster or other EPS based ETICS systems and it contributes to the protection of the system against weath-ering and provide a decorative finish. It is also applicable as a finishing layer of properly dried (at least 3 months) cement plaster inside and outside of the buildings.Coverage: – floated rendering with maximum particle size 1.5 mm: 2.2–2.5 kg/m2 – floated rendering with maximum particle size 2.0 mm: 2.5–2.8 kg/m2 – ribbed rendering with maximum particle size 1.5 mm: 2.5–2.8 kg/m2 – ribbed rendering with maximum particle size 2.0 mm: 2.8–3.0 kg/m2

Temperature during application: (+)5 – (+)25 °C Drying time: 12–24 hours (depending on weather conditions)Storage, expiry date: under dry conditions, protected against atmospheric exposure, especially sun-radiation and other heat sources. Storing temperature is between (+)5 °C and (+)25 °C. In case of the prescribed storage and handling conditions, the expiry date of the product is 18 months after production.Available: in buckets of 25 kg

Code

Floated - 1.5 mm 0171-1… Ribbed – 1.5 mm 0172-1…Floated - 2 mm 0171-2… Ribbed - 2 mm 0172-2…

acrylic finishing coat

universal primer

Material: ready to use liquid, mixture of pigments and fillers dispersed in wateracrilyc dispersion with additives Application: very thin key coat, which may be applied to the base coat and is intended to act as a preparation for the application of the finishing coat Coramix.Coverage: 2 - 3 dl/m2 of the concentrated primerDilution: depending on the water-absorbing ability of the base coat or surface (maximum in the ratio of: 2 part of primer : 1 part of water)Temperature during application: (+)5 – (+)25 °C Drying time: 4 – 6 hoursStorage, expiry date: under dry conditions, protected against atmospheric expo-sure, especially sun-radiation and other heat sources. Storing temperature is between (+)5 °C and (+)25°C. In case of the prescribed storage and handling con-ditions, the expiry date of the product is 12 months after production.

Available Code

5 kg 0159-0000500525 kg 0159-00000025

THERMAL INSULATION SYSTEM10MASTERPLAST GROUP INTERNATIONAL

silicone finishing coat

marble plaster

Material: ready to use paste, mixture of aggregates, pigments and fillers dispersed in silicone emulsion with additives.Properties: the dried coat is flexible, UV-resistant with good water-repellent and vapour trans-mission ability. Application: it is applied to the base coat as a top coat of Thermomaster (or other EPS and mineralwool based) ETICS systems. It contributes to the protection of the system against weathering and provide a decorative finish. It is also applicable as a finishing layer of properly dried (at least 3 months) cement plaster inside and outside of the buildingsCoverage: - floated rendering with maximum particle size 1.5 mm: 2.2–2.5 kg/m2 - floated rendering with maximum particle size 2.0 mm: 2.5–2.8 kg/m2 - ribbed rendering with maximum particle size 1.5 mm: 2.5–2.8 kg/m2

- ribbed rendering with maximum particle size 2.0 mm: 2.8–3.0 kg/m2

Temperature during application: (+)10 – (+)25 °C Drying time: ~24 hours (depending on weather conditions)Storage, expiry date: under dry conditions, protected against atmospheric exposure, espe-cially sun-radiation and other heat sources. Storing temperature is between (+)5 °C and (+)25 °C. In case of the prescribed storage and handling conditions, the expiry date of the product is 12 months after production.Available: in buckets of 25 kg

Code

Scraped 1.5 mm 0161-1… Rolling grains of 1.5 mm 0162-1…Scraped 2 mm 0161-2… Rolling grains of 2 mm 0162-2…

Material: ready to use paste, mixture of synthetic-resin, coloured marble granules and additives.Application: it is applied as a top coat to the base coat of XPS boards at the socle. Coverage: 4 – 5 kg/m2

Properties: the dried coat is flexible, moisture- and UV-resistant with good water-repellent ability. Application temperature: +10 – 25 °C.Drying time: ~72 hours (20 °C 65% of vapour)Storage, expiry date: under dry conditions, protected against atmospheric exposure, especial-ly sun-radiation and other heat sources. Storing temperature is between (+)5 °C and (+)25 °C. In case of the prescribed storage and handling conditions, the expiry date of the product is 12 months after production.Available: in buckets of 23 kg

Code

0123-......

THERMAL INSULATION SYSTEM11MASTERPLAST GROUP INTERNATIONAL

Material: aluminumApplication: Intended to be used before the bonding of the first row of EPS, with perforated water- dripping part. Additional products: Hammer fixed expansion plug, profile connector, plastic spacer

Product name Available Code

UZ 20 (2 cm) 2 m×25 pcs=50 m/bundle 0110-0Z020000UZ 30 (3 cm) 2 m×25 pcs=50 m/bundle 0110-0Z030000UZ 40 (4 cm) 2 m×25 pcs=50 m/bundle 0110-0Z040000UZ 50 (5 cm) 2 m×25 pcs=50 m/bundle 0110-0Z050000UZ 60 (6 cm) 2 m×25 pcs=50 m/bundle 0110-0Z060000UZ 70 (7 cm) 2 m×25 pcs=50 m/bundle 0110-0Z070000UZ 80 (8 cm) 2 m×25 pcs=50 m/bundle 0110-0Z080000UZ 100 (10 cm) 2 m×25 pcs=50 m/bundle 0110-0Z100000UZ 120 (12 cm) 2 m×25 pcs=50 m/bundle 0110-0Z120000

UZ Socle profile

Material: Polypropylene sleeve with plastic nailApplication: for mechanical fixing of the thermal insulation boardsQuantity: according to the installation guidline (4 – 6 – 8 – 12 pcs/m2)Sizes: Sleeve diameter: Ø10 mm, lengths of anchor: 70 – 90 – 110 – 120 – 140 – 160 mmTension load in concrete and solid brick (planning value): 012 kN, anchoring depth: 40 mmTension load in hollow brick (planning value): 0.08 kN, anchoring depth: min. 50 mm

Product name Packaging Code

THERMOMASTER® D 10/70 mm 250 pcs/box 0115-00070250THERMOMASTER® D 10/90 mm 250 pcs/box 0115-00090250THERMOMASTER® D 10/110 mm 250 pcs/box 0115-00110250THERMOMASTER® D 10/120 mm 250 pcs/box 0115-00120250THERMOMASTER® D 10/140 mm 250 pcs/box 0115-00140250THERMOMASTER® D 10/160 mm 250 pcs/box 0115-00160250

D anchor

THERMAL INSULATION SYSTEM12 MASTERPLAST GROUP INTERNATIONAL

D PLUS anchor

D-H anchor with plastic cap and metal nail

Material: Polypropylene sleeve with plastic nailApplication: for mechanical fixing of the thermal insulation boardsQuantity: according to the installation guidline (4 – 6 – 8 – 12 pcs/m2)Sizes: Sleeve diameter: Ø10 mm, lengths of anchor: 90 – 110 – 130 – 150 – 170 – 190 mmTension load in concrete and solid brick (planning value): 0.18kN, anchoring depth: 40 mmTension load in hollow brick (planning value): 0.09kN, anchoring depth: min. 50 mm

Product name Packaging Code

THERMOMASTER® D-PLUS 10/90 mm 250 pcs/box 0115-10090250THERMOMASTER® D-PLUS 10/110 mm 250 pcs/box 0115-10110250THERMOMASTER® D-PLUS 10/130 mm 250 pcs/box 0115-10130250THERMOMASTER® D-PLUS 10/150 mm 250 pcs/box 0115-10150250THERMOMASTER® D-PLUS 10/170 mm 250 pcs/box 0115-10170250THERMOMASTER® D-PLUS 10/190 mm 250 pcs/box 0115-10190250

Material: Polyamide sleeve, coated steel nail with polyamide capApplication: for mechanical fixing of the thermal insulation boardsQuantity: according to the installation guidline (4 – 6 – 8 –12 pcs/m2) Sizes: Sleeve diameter: Ø8mm, lengths of anchor: 90 – 110 – 130 – 150 – 170 – 190 mmTension load in concrete and solid brick (planning value): 0.3 kN, anchoring depth: 40 mmTension load in hollow brick (planning value): 0.18 kN, anchoring depth: 50 mm

Product name Available Code

THERMOMASTER® D-H 8/90 mm 250 pcs/box 0118-00090250THERMOMASTER® D-H 8/110 mm 250 pcs/box 0118-00110250THERMOMASTER® D-H 8/130 mm 250 pcs/box 0118-00130250THERMOMASTER® D-H 8/150 mm 250 pcs/box 0118-00150250THERMOMASTER® D-H 8/170 mm 250 pcs/box 0118-00170250THERMOMASTER® D-H 8/190 mm 250 pcs/box 0118-00190250

THERMAL INSULATION SYSTEM13MASTERPLAST GROUP INTERNATIONAL

Material: Impact resistantolypropyleneApplication: For fixing both EPS and mineral wool insulation – in combination with appropriate screws – to façade walls made of timber, metal, plasterboard, etc.Quantity: according to the installation guidline (8–12 pcs/m2)

Available Code

100 pcs/box 0116-00010100

D-WM insulation flange with cover cap

ALU corner bead

PVC corner bead

Material: made of aluminium with bonded fiberglass meshApplication: embedded in the base coat, it improves the protection and mechanical resistance of the corners, accelerate the works, because the fiberglass mesh is not necessary to be folded over the cornerType: ALU corner with 7+7 cm,10+10 cm or 10+15 cm wide fiberglass mesh

Type Available Code

THERMOMASTER® ALU-L 7+7 2.5 m × 50 pcs=125 m/bundle 0105-07070000THERMOMASTER® ALU 10+10 2.5 m × 50 pcs=125 m/bundle 0105-10100000THERMOMASTER® ALU 10+15 2.5 m × 50 pcs=125 m/bundle 0105-10150000

Material: made of PVC with bonded fiberglass meshApplication: embedded in the base coat, it improves the protection and mechanical resistance of the corners, accelerate the works, because the fiberglass mesh is not necessary to be folded over the corner. Type: PVC corner with 10+10cm or 10+15cm wide fiberglass mesh

Type Packaging Code

THERMOMASTER® PVC 10+10 2.5 m × 50 pcs=125 m/bundle 0107-10100000THERMOMASTER® PVC 10+15 2.5 m × 50 pcs=125 m/bundle 0107-10150000

THERMAL INSULATION SYSTEM14 MASTERPLAST GROUP INTERNATIONAL

PVC-B balcony profile with mesh

Material: made of PVC with alkali-resistant fiberglass meshApplication: fixed at the lower edges of balcony slabs, it prevents the water from flowing back, that could cause frost damages.

Length Packaging Code

2.5 m 2.5 m × 20 pcs=50 m/bundle 0109-00250000

W-PROF Connecting profile to frames

Material: hard PVC profile with flexible, watertight, self-adhesive stripApplication: Self-adhesive PVC-profile with sealing lips including fibre mesh for exact connections to soffits with insulation systems, sealing lips and movement joint. Minimum fixing temperature: +5 °C.

Length Packaging Code

2.5 m 2.5 m × 20 pcs = 50 m/bundle 0112-00250000

Material: polyamide sleeve with plastic nail strengthened with fibreglass.Application: for mechanical fixing of the thermal insulation boardsQuantity: according to the installation guidline (4 – 6 – 8 – 12 pcs/m2)Sizes: sleeve diameter: Ø8mm, lengths of anchor: 75 – 95 – 115 – 135 – 155 mm Tension load in concrete and solid brick (planning value): 0.27 kN, depth of anchoring: 25 mm Tension load in hollow brick (planning value): 0.15 kN, depth of fix depth of anchoring: 35 mm

Length Packaging Code

75 mm 200 pcs/box 0114-00075000 95 mm 200 pcs/box 0114-00095000115 mm 200 pcs/box 0114-00115000135 mm 200 pcs/box 0114-00135000155 mm 200 pcs/box 0114-00155000175 mm 200 pcs/box 0114-00175000

IDK-T anchor

THERMAL INSULATION SYSTEM15MASTERPLAST GROUP INTERNATIONAL

Polyamide sleeve, coated steel nail with polyamide capApplication: for mechanical fixing of the thermal insulation boardsQuantity: according to the installation guidline (4 – 6 – 8 – 12 pcs/m2)Sizes: sleeve diameter: Ø8 mm, lengths of anchor: 75 – 95 – 115 – 135 – 155 – 175 – 195 – 215 – 235 – 255 – 275 – 295 mmTension load in concrete and solid brick (planning value): 0.27 kN, depth of anchoring: 25 mm Tension load in hollow brick (planning value): 0.15 kN, depth of fix depth of anchoring: 35 mm

Length Packaging Code

115 mm 200 pcs/box 0114-10115000135 mm 200 pcs/box 0114-10135000155 mm 200 pcs/box 0114-10155000175 mm 100 pcs/box 0114-10175000195 mm 100 pcs/box 0114-10195000215 mm 100 pcs/box 0114-10215000235 mm 100 pcs/box 0114-10235000

TID-T anchor

Material: PlasticApplication: it ensures the proper lengthening of socle profiles

Width Packaging Code

30 mm 100 pcs/box 0111-03000000

Profile connector

Material: plasticApplication: it ensures the levelleing of uneven surface under the socle profile.Marking: 3 mm – green, 5 mm – yellow, 10 mm – light blue

With Packaging Code

3 mm 100 pcs/box 0112-03000000 5 mm 100 pcs/box 0112-0500000010 mm 100 pcs/box 0112-10000000

plastic spacer for socle profiles

THERMAL INSULATION SYSTEM16 MASTERPLAST GROUP INTERNATIONAL

Material: AluminumApplication: embedded in the base coat, it improves the protection and mechanical resistance of the corners, but the fiberglass mesh must be folded over at the profile.Length: 2 – 2.5 – 3 m

Type Packaging Code

MASTERPROFIL® ALU 12 × 24 2 m 2 m × 50 pcs=100 m/bundle 0104-12200100MASTERPROFIL® ALU 12 × 24 2.5 m 2.5 m × 50 pcs=125 m/bundle 0104-12250125MASTERPROFIL® ALU 12 × 24 3 m 3 m × 50 pcs=150 m/bundle 0104-12300150

MASTERPROFIL® ALU 24 × 24 2 m 2 m × 50 pcs=100 m/bundle 0104-24200100MASTERPROFIL® ALU 24 × 24 2.5 m 2.5 m × 50 pcs=125 m/bundle 0104-24250125MASTERPROFIL® ALU 24 × 24 3 m 3 m × 50 pcs=150 m/bundle 0104-24300150

MASTERPROFIL® ALU-L 2 m × 50 pcs=100 m/bundle 0104-20200100MASTERPROFIL® ALU-L 2.5 m × 50 pcs=125 m/bundle 0104-20250125MASTERPROFIL® ALU-L 3 m × 50 pcs=150 m/bundle 0104-20300150

MASTERPROFIL® ALU 135° 2 m × 50 pcs=100 m/bundle 0104-35200100MASTERPROFIL® ALU 135° 2.5 m × 50 pcs=125 m/bundle 0104-35250125MASTERPROFIL® ALU 135° 3 m*50 pcs=150 m/bundle 0104-35300150

ALU corner bead for jointing

Edge protection PVC profile

PVC Arch form profile

Material: PVCApplication: embedded in the base coat, it improves the protection and mechanical resistance of the corners, but the fiberglass mesh must be folded over at the profile.

Type Packaging Code

MASTERPROFIL® PVC 2.5 m 2.5 m × 20 pcs=50 m/bundle 0106-00250000

Material: PVCApplication: embedded in the base coat, it improves the protection and mechanical resistance of curved edges (e.g. arches).

Length Available Code

2.5 m 2.5 m × 20 pcs=50 m/bundle 0108-00250000

THERMAL INSULATION SYSTEM17MASTERPLAST GROUP INTERNATIONAL

Material: AluminumApplication: fixed at the lower edges of balcony slabs or above windows, it prevents the water from flowing back, that could cause frost damages

Type Packaging Code

9011 2.5 m × 20 pcs/bundle 0109-19011000

9011 – Water drip alu profile

9011

Material: PVC, with alkali-resistant fiberglass meshApplication: Corner profile in PVC on roll with bonded glassfibre mesh The folding line allows corner executions of different angels (e.g. 135°). The roll length of 50 m allows joint free lining. Borders of different win-dow sizes can be done without waste.Advantage: easy-to-use due to the rolled packaging, universally appli-cable to most of the wall corner angles.

Type Packaging Code

3752 50 m/roll 0108-13752000

3752 – PVC corner profile with folding line, with mesh

THERMAL INSULATION SYSTEM18 MASTERPLAST GROUP INTERNATIONAL

Material: PVC, with flexible tapes in the middle and alkali-resistant fiberglass meshApplication: Embedded in the base coat for covering of expansion joints. Only for vertical application!

Type Available Code

3035 2.5 m/pcs 0121-13035000

3035 – Expansion joint PVC profile

Material: Polypropylene sleeve with steel nail Application: For the fastening of e.g. socle profile, UD profile in the floor, ceiling or wall. Sizes: sleeve diameter: Ø6 mm, with different lengths (40 – 60 – 80 mm).Rules of installation: Anchorage depth: 35 mm in solid brick or concrete, 45 mm in hollow brick (cavity brick),

Type: Available: Code

6 × 40 200 pcs/box 0717-64002000 6 × 60 200 pcs/box 0717-66002000 6 × 80 100 pcs/box 0717-68001000

PLUG dowel

19MASTERPLAST GROUP INTERNATIONAL

For further information and downloads, please visit to our website

www.masterplastgroup.com

Notes

MASTERPLAST Group Zrt.8143 Sárszentmihály, Árpád u. 1/a, HungaryPhone: +36-22-801-300, Fax.: +36-22-801-382 E-mail: [email protected]

MASTERPLAST Kft.8143 Sárszentmihály, Árpád u. 1/a., HungaryPhone: +36-22-801-300Fax: +36-22-801-382E-mail: [email protected]

MASTERPLAST România s.r.l.410605 Oradea, Şos. Borşului, nr. 45, RomaniaPhone: +40-259-465-456, Fax: +40-259-435-134E-mail: [email protected]

Î.C.S. MASTERPLAST CONSTRUCT S.R.L.2019, şos. Munceşti, nr.799/3, Chişinău, Republica MoldovaPhone / Fax: +373-22-524-148Phone: +373-69-314-042E-mail: [email protected]

MASTERPLAST YU d.o.o.24000 Subotica, Bodrogvari Ferenc 172, SerbiaPhone: +381- 24-625-825 Fax: +381-24-625-804E-mail: [email protected]

MASTERPLAST d.o.o.31304 Duboševica, Trg Hrvatske Mladeži 2, CroatiaPhone: +385-31-736-512; Fax: +38-5-31-736-513E-mail: [email protected]

MASTER PLAST s.r.o925 21 Sládkovičovo, Veľkoúľanská cesta 1339, SlovakiaPhone: +421-31-784-2181Fax: +421-31-784-2180E-mail: [email protected]

MASTER PLAST PLUS s.r.o.19600 Praha 9-Treboradice, Za tratí 197, Czech RepublicPhone: +42-0-286-850-565, Fax: +42-0-286-850-386E-mail: [email protected]

MASTERPLAST SP. z o.o.Ul. Kolejowa 23, 62-090 Rokietnica, PolandPhone: +48-61-896-35-58/59; +48-61-816-19-97;Fax. +48-61-814-11-79E-mail: [email protected]

MASTERPLAST DeutschlandProduktions- und Vertriebs GmbH39114 Magdeburg, Breite Str. 6f, Germany04519 Rackwitz, Kömmlitzer Str. 13, GermanyPhone: +49-0-34294-84662Fax: +49-0-34294-84663E-mail: [email protected]

MASTERPLAST Ukraina T.O.B.88000 Uzhgorod, Pavlovich u.5., UkrainePhone / Fax: +380-312-656093; +380-312-656073E-mail: [email protected]

MASTERPLAST Bulgaria EOOD1532 Sofia, MSK Kazichene, BulgariaPhone / Fax: +359-2-978-9791; +359-2-978-9764E-mail: [email protected]

Doo MASTERPLAST6250, Kičevo, 11 Septemvri 43, MacedoniaPhone: +389-45-223-766;Fax: +389-45-224-804E-mail: [email protected]

MASTERPLAST KO SHPK10000 Pristina, Rr. Drini i bardh , KosovoPhone: +377-44-250-877; +381-63-555-074E-mail: [email protected]

d.o.o. MASTERPLAST MONT85000 Bar, Jovana Tomaševića G-9, MontenegroPhone: +382-85-353-544; +382-69-657-131;Fax: +382-85-353-544E-mail: [email protected]

MASTERPLAST ÖSTERREICHProduktions- & Vertriebs GmbH3021 Pressbaum, Hauptstraße 119-5/4, AustriaPhone/ Fax: +43-0-2233-52244Mobile: +43-(0)676 - 710 80 82E-mail: [email protected]

MASTERPLAST ALB Sh.p.kTirane Llagja Ali Demi Kruga Shemsije Haka, AlbaniaE-mail: [email protected]

MASTERPLAST IGMIN D.O.O.78000 Banja Luka, Tunjice bb., Bosna i HercegovinaPhone: +387-51-386-486,

+387-51-386-437Fax: +387-51-388-966E-mail: [email protected]

MASTERPLAST China200433 Shanghai, Rm 1305, No. 2158 Siping Road, Fuqing Guoding Building, Yangpu District, ChinaPhone: +86 21 5506 2799Phone/Fax: +86 21 55063899E-mail: [email protected]