THERMAL INSULATION SYSTEM GENERAL DESCRIPTION OF THE SYSTEM
This short description introduces the Thermomaster external thermal insulation composite system and its components. This product catalogue and THERMOMASTER® Instruction Guidline issued by MASTERPLAST GROUP provide more detailed information about the system.
Components and structure of the THERMOMASTER® A02 EPS system:
Components and structure of the THERMOMASTER® rock wool system:
Before the start of construction works, the building must be examined: the material and the thickness of the wall, the potential thermal bridges and their positions, the quality and moisture content of the surface (underground), as well as the quality and the thickness of the existing plaster layer.
1. THERMOMASTER® Socle profile 2. MASTERFIX® PRO or FALFIX Plus adhesive - 2.5–4 kg/m2
3. ISOMASTER® EPS H 80 thermal insulation 4. Anchor (when required) 5. Corner bead with mesh 6. MASTERFIX® PRO or FALFIX base coat 3–3.5 kg/m2
7. MASTERNET® fiberglass mesh 1.1m2/m2
8. MASTERFIX® PRO or FALFIX base coat 9. CORATREND® 1.6–2 dl/m2
10. CORATREND® finishing layer 2.3–3 kg/m2
11. embossed XPS insulation12. CORAMIX marble plaster 4–5 kg/m2
11.
1.
5.3.
2.
4.
12.
10.
9.
8.
7.
6.
1. THERMOMASTER® socle profile 2. MASTERFIX® ROCK adhesive 4-5 kg/m2
3. NOBASIL FKD stone wool thermal insulation 4. Anchor (when required) 5. Corner bead with mesh 6. MASTERFIX® ROCK base coat 6–7 kg/m2
7. MASTERNET fiberglass mesh 1.1 m2/m2
8. MASTERFIX® ROCK base coat 9. Coramix key coat 2–3 dl/m2 10. Coramix silicone finishing coat 2.3–3 kg/m2
11. embossed XPS insulation12. CORAMIX marble plaster 4–5 kg/m2
11. 1.
5.
3.2.
4.
12.
10.
9. 8.
7. 6.
THERMAL INSULATION SYSTEM3MASTERPLAST GROUP INTERNATIONAL
Depending on the material and thickness of the wall, the following insulation thickness are recommended to be observed (for apartments or offices):
Material ISOMASTER® U value (W/m2K) Improvement of the insulation EPS 80 achieved with the ability of the structure achieved Insulation THER MO MAS TER® the THERMOMASTER®
thickness system system
Small-sized solid brick (25 cm) 8 cm 0.39 79% Small-sized solid brick (38 cm) 8 cm 0.38 74% Reinforced-concrete wall, (20 cm) 9 cm 0.38 87% Panel building 6 cm 0.37 58% Hollow brick (B30 – 30cm) 8 cm 0.37 75% Modern hollow brick (30 cm) 7* cm 0.29 60% Porous concrete (30 cm) 4* cm 0.31 53%
*in case of walls mentioned above, application of the thicker insulation than required is necessary in considerations of risk of vapour condensation. In bathrooms and wet spaces the internal surface of the walls must be tiled up to the ceiling, and only silicone finishing coat can be applied outside (for more details see: THERMOMASTER® Instruction Guidline).
Recommendations for the application of the system:The wall must be free of loose plasters, particles and paints, if necessary, the surface unevenness can be repaired by cement plaster. In case of strongly absorbing wall (e.g. porenbeton), it is recommended to use MASTERFIX® PRIMER). First step is the fixing of the socle profile by hammer fixed expansion plug (4 pcs/m), minimum 30 cm above the level of ground or pavement. The unevenness of the wall can be equalised with levelling pieces, the lengthening of the socle profile is with profile connector . The temperature of air must be over (+)5 C during the adhesion of ISOMASTER® EPS boards. The adhesive material could happen with MASTERFIX® PRO or FALFIX Plus. The dry material is mixed with water as specified on the packaging and mixed again after 2–3 minutes of rest. The mixed adhesive should be used within 20–30 minutes depending on the ambient temperature, but dilution of it after mixing is not allowed. The adhesive should be applied alongside, around as well as in 2-3 spots on the surface of the insulting sheets, (do not apply the bonding material onto the edges of the board). The bonded surface is min 30% of the tight-jointed ISOMASTER® EPS board, the thickness of the adhesive should be 0.5–2.0 cm. After setting of the adhesive (minimum 1–2 days, depending on the temperature), the following step is the eliminating of the surface unevenness and anchoring. If the height of the fa ade is less than 8 m, anchoring is only necessary, when the bonded surface were critical (e.g. plastered, painted, strongly absorbing). Over 8 meter building height, supplementary anchoring is always important, 4 – 8 –12 pcs/m2 is recommended, depending on the type of anchor, material of the wall and the building height (for more details see: THERMOMASTER® Instruction Guidline). The respective anchoring depths must be always observed, and kept (e.g. in consideration of the thickness of existing plastering).The application of the corner profiles happens before applying of the base coat and fiberglass mesh. This working process is sensitive to weather conditions, the ideal ambient and surface temperature is (+)5 – (+)25 °C. During the setting of the base coat (depending on weather but minimum 1–3 days), the temperature is not allowed to sink under (+)5°C, in case of too warm (over (+)25 °C) or windy weather, supplementary precautions must be made. For base coating MASTERFIX® PRO or FALFIX Plus are also applicable. The adequately mixed material must be used within 20–30 minutes. The mate-rial (~3 kg/m in the first layer) is applied onto the ISOMASTER® EPS surface by a notched trowel, then the fiberglass mesh must be embedded with 10 cm overlapping. The second layer of base coat requires only ~1.5 kg/m2 material.A thin key coat (CORATREND Primer or Coramix Primer) is necessary after setting of the base coat, which is intended to act as a preparation for the application of the finishing coat. Before applying the finishing coat, the primer must be com-pletely dried. The top coat (Coratrend or Coramix) can be made of acrylic or silicon dispersion. A considerable advantage of silicone dispersion, that its vapour transmission and water-repellent ability is better. Floated and ribbed structure with particle size of 1.5 mm and 2 mm can be chosen. When choosing the colour of the finishing coat, it mustb considered, that the same colour of look differently on big surface than on the colour patterns.
THERMAL INSULATION SYSTEMMASTERPLAST GROUP INTERNATIONAL4
Before the colouring works, the following tasks must be performed:• on a façade, only material made of the same production charge (indicated on label) can be used, otherwise the materials
derived from different charges must be mixed. • the plaster deposited on the cover of the bucket must be scraped back into the bucket. • CORATREND® render can be diluted with maximum 0.5 – 2.5 dl of water / bucket, depending on the weather conditions,
the amount of added pigment and the absorption capacity of the base coat. For every bucket the same quantity of water must be added, then mixed evenly, but the dilution extends the setting time on the wall, especially when the vapour content of the air is high.
Applying of CORATREND® top coat is also very sensitive to weather, warm and windy weather is not suitable for high quality work. The optimal temperature is about (+)15 - (+)25 °C. Between (+)25 - (+)30 °C, colouring could happen only on shaded surface. Cold weather (below 10 °C) and the high vapour content (over 75%) is not proper. Fresh top coat should be protected from wind, intensive UV radiation freezing and rain. For the insulation of the socle part of the building, XPS thermal insulation can be used, the bonding and coating happens on similar way, but the finishing layer is CORAMIX marble plaster.
Store vertically
To be kept indoors, in a dry place, protected from rain
Protected from sun and radiating heat
Product Description
Technical and Safety Data Sheet
CE certificate
Frost hazard
Expiry date: 1 year from production
Icons
THERMAL INSULATION SYSTEM5MASTERPLAST GROUP INTERNATIONAL
Material: alkaliresistant fiberglassApplication: Strenghtening mesh for Thermomaster® external thermal insulation sys-tem and reinforcement of internal cement plaster and plastic waterproofing.Quantity: 1.1 m2/net m2
Types: 125, 145, and 160 g/m2
Tensile strength after ageing: (MD/XD) MASTERNET® PREMIUM R-96 (125g) = 1100/900 N/5 cm MASTERNET® PREMIUM R-117 (145g) = 1500/1200 N/5 cm MASTERNET® PREMIUM R-131 (160g) = 1500/1500 N/5 cmRelevant specifications: Mastermesh 145 and 160 comply with the requirements of ETAG 004 and EN 13499.
Type of mesh Roll size Code
MASTERNET® PREMIUM R-96 (125 g) 1.1 m×50 fm=55 m2 0101-096WH055MASTERNET® PREMIUM R-117 (145 g) 1.1 m×50 fm=55 m2 0101-117WH055MASTERNET® PREMIUM R-131 (160 g) 1.1 m×50 fm=55 m2 0101-131WH055
PREMIUM fibreglass mesh
Material: alkaliresistant fiberglassApplication: Strenghtening mesh for Thermomaster® external thermal insulation system and reinforcement of internal cement plaster and plastic waterproofing.Quantity: 1.1 m2/net m2
Types: 125, 145, and 160 g/m2
Tensile strength after ageing (MD/XD) MASTERNET® A-125 = 800/1050 N/5 cm MASTERNET® A-145 = 1100/1450 N/5 cm MASTERNET® A-160 = 1250/1800 N/5 cmRelevant specifications: Mastermesh 145 and 160 comply with the requirements of ETAG 004.
Type of mesh Roll size Code
MASTERNET® A-125 1m×50 fm=50 m2 0102-125WH000
MASTERNET® A-145 1m×50 fm=50 m2 0102-145WH000
MASTERNET® A-160 1m×50 fm=50 m2 0102-160WH000
fibreglass mesh
THERMAL INSULATION SYSTEM6MASTERPLAST GROUP INTERNATIONAL
Material: expanded polystyreneApplication: Thermal insulation of external thermal insulation systems, covered with proper finishing coat (e.g. acrylic or silicone rendering).Quantity: 1.02 m2/net m2
Designation: EPS EN 13163 T2-L2-W2-S2-P4-BS125-CS(10)80-DS(N)2-DS(70)1-TR150Compression strength: 80 kPa Marking: red lineReaction to fire: Euroclasse: E (according to EN 13501-1)Relevant specifications: EN 13163 and EN 13499
Width Available Code
2 cm 0,24 m3/bale, 24 pcs/bale 0501-08002000
3 cm 0,24 m3/bale, 16 pcs/bale 0501-08003000
4 cm 0,24 m3/bale, 12 pcs/bale 0501-08004000
5 cm 0,25 m3/bale, 10 pcs/bale 0501-08005000
6 cm 0,24 m3/bale, 8 pcs/bale 0501-08006000
7 cm 0,245 m3/bale, 7 pcs/bale 0501-08007000
8 cm 0,24 m3/bale, 6 pcs/bale 0501-08008000
10 cm 0,25 m3/bale, 5 pcs/bale 0501-08010000
12 cm 0,24 m3/bale, 4 pcs/bale 0501-08012000
Other thickness with special delivery date for order
Material: water-repellent insulation, made of synthetic resin bonded mineral wool fibres. Field of application: Thermal, sound and fire-resistant insulation of external thermal insula-tion systems, covered with proper finishing coat (e.g. silicone rendering).Designation: MW-EN 13162 -T5 - DS(TH) - CS(10)40 - TR15 – WS - WL(P) - MU1,4 Density: 20-50 mm, 150 kg/m2, 60-160 mm, 140 kg/m2 Declared thermal conductivity (λD): 0.039 W/mK. Reaction to fire: A1 Compression strength (10%): 40 kPa (40 –160 mm) Tearing strength (perpendicular to faces): 15 kPa (40 –160 mm) Water vapour resistance factor (μ): 1.4 Size of board: 600 × 1000 mm
Width Available Code
NOBASIL FKD 2 cm 7.2 m2 0519-FKD02000
NOBASIL FKD 5 cm 3 m2 0519-FKD05000
NOBASIL FKD 6 cm 2.4 m2 0519-FKD06000
NOBASIL FKD 8 cm 1.8 m2 0519-FKD08000
NOBASIL FKD 10 cm 1.8 m2 0519-FKD10000
Only for order
EPS H-80
NOBASIL FKD (TF) stone wool thermal insulation
THERMAL INSULATION SYSTEM7MASTERPLAST GROUP INTERNATIONAL
Material: embossed extruded polystyrene with flat edge profileApplication: thermal insulation of external thermal insulation systems, even at surfaces exposed to wetness (e.g.: by socle)Quantity: 1.02 m2/net m2
Designation: XPS EN 13164 T1-CS(10/Y)200-DS(TH)-DLT(2)5-CC(2/1.5/50)100-MU200-TR200Compression strength: 200-300 kPa Reaction to fire: Euroclasse: E (according to EN 13501-1)Relevant specifications: EN 13164 and EN 13499
Width Available Code
2 cm 0.300 m3/bale, 20 pcs/bale 0510-28002000
3 cm 0.315 m3/bale, 14 pcs/bale 0510-28003000
4 cm 0.300 m3/bale, 10 pcs/bale 0510-28004000
5 cm 0.300 m3/bale, 8 pcs/bale 0510-28005000
6 cm 0.315 m3/bale, 7 pcs/bale 0510-28006000
8 cm 0.300 m3/bale, 5 pcs/bale 0510-28008000
10 cm 0.300 m3/bale, 4 pcs/bale 0510-28010000
12 cm 0.360 m3/bale, 4 pcs/bale 0510-28012000
2800 CStyrodur®
Material: ready to use liquid dispersion Application: very thin key coat which may be applied to the base coat and is intended to act as a preparation for the application of the finishing coat. It also can be used as a general primer.Coverage: 1–1.5 dl/m2 of the concentrated primerDilution: depending on the water-absorbing ability of the base coat or surface (maximum in the ratio of: 1 part of primer : 3 part of water)Temperature during application: (+)5 – (+)25°C (above (+)25°C it’s need additional measure)Drying time: 2–6 hours
Available Code
1 litre can 0103-10001001
5 litre can 0103-10001005
PRO adhesive and base coat render
Material: cement-bonding adhesive mortar with synthetic resin additive Application: it is used for the fixing of the insulation product (e.g. EPS, XPS) to the wall or applied directly onto the insulation product for the embedding of the fiberglass mesh - this layer provides most of the mechanical properties of the rendering. Coverage: as an adhesive: 2.5–4 kg/m2, as a base coat: 3 kg/m2 (in first layer)Application temperature: (+)5 – (+)25°C (above (+)25°C it’s need additional measure)Bond strength: 120kPa to EPS boardsApplicable: within 20 minutes after mixingRelated regulations: ETAG 004, EN 13499, EN 13499
Available Code
25 kg bag (1050 kg/palette) 0103-01111025
PRIMER
THERMAL INSULATION SYSTEM8 MASTERPLAST GROUP INTERNATIONAL
Material: cement-bonding adhesive mortar with synthetic resin additive and high vapour transmission ability.Application: it is used for the fixing of the stone-wool insulation (e.g. Nobasil FKD) to the wall or applied directly onto the insulation product for the embedding of the fiberglass mesh - this layer provides most of the mechanical properties of the rendering. Coverage: as an adhesive for total surface of the insulation (so-called lamell wool): 7-9 kg/m2, for ~40% partial surface fixing: ~4-5 kg/m2, as a base coat: ~6 kg/m2 (in first layer)Application temperature: (+)5 – (+)25°C (above (+)25°C it’s need additional measure)Applicable: within 20 minutes after mixingRelated regulations: ETAG 004, EN 13499
Available Code
25 kg bag (1050 kg/pallets) 0103-01201025
adhesive and base coat render
Material: cement-bonding adhesive mortar with synthetic resin additive Application: it is used for the fixing of the insulation product (e.g. EPS, XPS) to the wall or applied directly onto the insulation product for the embedding of the fiberglass mesh – this layer provides most of the mechanical properties of the rendering. Coverage: as an adhesive: 2.5–4 kg/m2, as a base coat: 3 kg/m2 (in first layer)Application temperature: (+)5 – (+)25°C (above (+)25°C it’s need additional measure)Bond strength: 150 kPa to EPS boardsApplicable: within 30 minutes after mixingRelated regulations: ETAG 004, EN 13499
Available Code
25 kg bag (1000 kg/palette) 0103-03001025
Material: ready to use liquid, mixture of pigments and fillers dispersed in water acrilyc dispersion with additives Application: very thin key coat, which may be applied to the base coat and is intended to act as a preparation for the application of the finishing coat Coratrend.Coverage: 1.6–2 dl/m2 Dilution: depending on the water-absorbing ability of the base coat or surface (maximum in the ratio of: 2 part of primer : 1 part of water)Temperature during application: (+)5 – (+)25 °C (above (+)25 °C it’s need additional measure)Drying time: 2–6 hoursStorage, expiry date: under dry conditions, protected against atmospheric exposure, especially sun-ra-diation and other heat sources. Storing temperature is between (+)5 °C and (+)25 °C. In case of the pre-scribed storage and handling conditions, the expiry date of the product is 18 months after production.
Available Code:
in buckets of 8 and 16 litres 0179-0…….
primer
THERMAL INSULATION SYSTEM9MASTERPLAST GROUP INTERNATIONAL
Material: ready to use paste, mixture of aggregates, pigments and fillers dispersed in copolymer of styreneacrylic dispersion with additives.Properties: the dried coat is flexible, durable, UV-resistant with good water-repellent ability.Application: it is applied to the base coat as a top coat of Thermomaster or other EPS based ETICS systems and it contributes to the protection of the system against weath-ering and provide a decorative finish. It is also applicable as a finishing layer of properly dried (at least 3 months) cement plaster inside and outside of the buildings.Coverage: – floated rendering with maximum particle size 1.5 mm: 2.2–2.5 kg/m2 – floated rendering with maximum particle size 2.0 mm: 2.5–2.8 kg/m2 – ribbed rendering with maximum particle size 1.5 mm: 2.5–2.8 kg/m2 – ribbed rendering with maximum particle size 2.0 mm: 2.8–3.0 kg/m2
Temperature during application: (+)5 – (+)25 °C Drying time: 12–24 hours (depending on weather conditions)Storage, expiry date: under dry conditions, protected against atmospheric exposure, especially sun-radiation and other heat sources. Storing temperature is between (+)5 °C and (+)25 °C. In case of the prescribed storage and handling conditions, the expiry date of the product is 18 months after production.Available: in buckets of 25 kg
Code
Floated - 1.5 mm 0171-1… Ribbed – 1.5 mm 0172-1…Floated - 2 mm 0171-2… Ribbed - 2 mm 0172-2…
acrylic finishing coat
universal primer
Material: ready to use liquid, mixture of pigments and fillers dispersed in wateracrilyc dispersion with additives Application: very thin key coat, which may be applied to the base coat and is intended to act as a preparation for the application of the finishing coat Coramix.Coverage: 2 - 3 dl/m2 of the concentrated primerDilution: depending on the water-absorbing ability of the base coat or surface (maximum in the ratio of: 2 part of primer : 1 part of water)Temperature during application: (+)5 – (+)25 °C Drying time: 4 – 6 hoursStorage, expiry date: under dry conditions, protected against atmospheric expo-sure, especially sun-radiation and other heat sources. Storing temperature is between (+)5 °C and (+)25°C. In case of the prescribed storage and handling con-ditions, the expiry date of the product is 12 months after production.
Available Code
5 kg 0159-0000500525 kg 0159-00000025
THERMAL INSULATION SYSTEM10MASTERPLAST GROUP INTERNATIONAL
silicone finishing coat
marble plaster
Material: ready to use paste, mixture of aggregates, pigments and fillers dispersed in silicone emulsion with additives.Properties: the dried coat is flexible, UV-resistant with good water-repellent and vapour trans-mission ability. Application: it is applied to the base coat as a top coat of Thermomaster (or other EPS and mineralwool based) ETICS systems. It contributes to the protection of the system against weathering and provide a decorative finish. It is also applicable as a finishing layer of properly dried (at least 3 months) cement plaster inside and outside of the buildingsCoverage: - floated rendering with maximum particle size 1.5 mm: 2.2–2.5 kg/m2 - floated rendering with maximum particle size 2.0 mm: 2.5–2.8 kg/m2 - ribbed rendering with maximum particle size 1.5 mm: 2.5–2.8 kg/m2
- ribbed rendering with maximum particle size 2.0 mm: 2.8–3.0 kg/m2
Temperature during application: (+)10 – (+)25 °C Drying time: ~24 hours (depending on weather conditions)Storage, expiry date: under dry conditions, protected against atmospheric exposure, espe-cially sun-radiation and other heat sources. Storing temperature is between (+)5 °C and (+)25 °C. In case of the prescribed storage and handling conditions, the expiry date of the product is 12 months after production.Available: in buckets of 25 kg
Code
Scraped 1.5 mm 0161-1… Rolling grains of 1.5 mm 0162-1…Scraped 2 mm 0161-2… Rolling grains of 2 mm 0162-2…
Material: ready to use paste, mixture of synthetic-resin, coloured marble granules and additives.Application: it is applied as a top coat to the base coat of XPS boards at the socle. Coverage: 4 – 5 kg/m2
Properties: the dried coat is flexible, moisture- and UV-resistant with good water-repellent ability. Application temperature: +10 – 25 °C.Drying time: ~72 hours (20 °C 65% of vapour)Storage, expiry date: under dry conditions, protected against atmospheric exposure, especial-ly sun-radiation and other heat sources. Storing temperature is between (+)5 °C and (+)25 °C. In case of the prescribed storage and handling conditions, the expiry date of the product is 12 months after production.Available: in buckets of 23 kg
Code
0123-......
THERMAL INSULATION SYSTEM11MASTERPLAST GROUP INTERNATIONAL
Material: aluminumApplication: Intended to be used before the bonding of the first row of EPS, with perforated water- dripping part. Additional products: Hammer fixed expansion plug, profile connector, plastic spacer
Product name Available Code
UZ 20 (2 cm) 2 m×25 pcs=50 m/bundle 0110-0Z020000UZ 30 (3 cm) 2 m×25 pcs=50 m/bundle 0110-0Z030000UZ 40 (4 cm) 2 m×25 pcs=50 m/bundle 0110-0Z040000UZ 50 (5 cm) 2 m×25 pcs=50 m/bundle 0110-0Z050000UZ 60 (6 cm) 2 m×25 pcs=50 m/bundle 0110-0Z060000UZ 70 (7 cm) 2 m×25 pcs=50 m/bundle 0110-0Z070000UZ 80 (8 cm) 2 m×25 pcs=50 m/bundle 0110-0Z080000UZ 100 (10 cm) 2 m×25 pcs=50 m/bundle 0110-0Z100000UZ 120 (12 cm) 2 m×25 pcs=50 m/bundle 0110-0Z120000
UZ Socle profile
Material: Polypropylene sleeve with plastic nailApplication: for mechanical fixing of the thermal insulation boardsQuantity: according to the installation guidline (4 – 6 – 8 – 12 pcs/m2)Sizes: Sleeve diameter: Ø10 mm, lengths of anchor: 70 – 90 – 110 – 120 – 140 – 160 mmTension load in concrete and solid brick (planning value): 012 kN, anchoring depth: 40 mmTension load in hollow brick (planning value): 0.08 kN, anchoring depth: min. 50 mm
Product name Packaging Code
THERMOMASTER® D 10/70 mm 250 pcs/box 0115-00070250THERMOMASTER® D 10/90 mm 250 pcs/box 0115-00090250THERMOMASTER® D 10/110 mm 250 pcs/box 0115-00110250THERMOMASTER® D 10/120 mm 250 pcs/box 0115-00120250THERMOMASTER® D 10/140 mm 250 pcs/box 0115-00140250THERMOMASTER® D 10/160 mm 250 pcs/box 0115-00160250
D anchor
THERMAL INSULATION SYSTEM12 MASTERPLAST GROUP INTERNATIONAL
D PLUS anchor
D-H anchor with plastic cap and metal nail
Material: Polypropylene sleeve with plastic nailApplication: for mechanical fixing of the thermal insulation boardsQuantity: according to the installation guidline (4 – 6 – 8 – 12 pcs/m2)Sizes: Sleeve diameter: Ø10 mm, lengths of anchor: 90 – 110 – 130 – 150 – 170 – 190 mmTension load in concrete and solid brick (planning value): 0.18kN, anchoring depth: 40 mmTension load in hollow brick (planning value): 0.09kN, anchoring depth: min. 50 mm
Product name Packaging Code
THERMOMASTER® D-PLUS 10/90 mm 250 pcs/box 0115-10090250THERMOMASTER® D-PLUS 10/110 mm 250 pcs/box 0115-10110250THERMOMASTER® D-PLUS 10/130 mm 250 pcs/box 0115-10130250THERMOMASTER® D-PLUS 10/150 mm 250 pcs/box 0115-10150250THERMOMASTER® D-PLUS 10/170 mm 250 pcs/box 0115-10170250THERMOMASTER® D-PLUS 10/190 mm 250 pcs/box 0115-10190250
Material: Polyamide sleeve, coated steel nail with polyamide capApplication: for mechanical fixing of the thermal insulation boardsQuantity: according to the installation guidline (4 – 6 – 8 –12 pcs/m2) Sizes: Sleeve diameter: Ø8mm, lengths of anchor: 90 – 110 – 130 – 150 – 170 – 190 mmTension load in concrete and solid brick (planning value): 0.3 kN, anchoring depth: 40 mmTension load in hollow brick (planning value): 0.18 kN, anchoring depth: 50 mm
Product name Available Code
THERMOMASTER® D-H 8/90 mm 250 pcs/box 0118-00090250THERMOMASTER® D-H 8/110 mm 250 pcs/box 0118-00110250THERMOMASTER® D-H 8/130 mm 250 pcs/box 0118-00130250THERMOMASTER® D-H 8/150 mm 250 pcs/box 0118-00150250THERMOMASTER® D-H 8/170 mm 250 pcs/box 0118-00170250THERMOMASTER® D-H 8/190 mm 250 pcs/box 0118-00190250
THERMAL INSULATION SYSTEM13MASTERPLAST GROUP INTERNATIONAL
Material: Impact resistantolypropyleneApplication: For fixing both EPS and mineral wool insulation – in combination with appropriate screws – to façade walls made of timber, metal, plasterboard, etc.Quantity: according to the installation guidline (8–12 pcs/m2)
Available Code
100 pcs/box 0116-00010100
D-WM insulation flange with cover cap
ALU corner bead
PVC corner bead
Material: made of aluminium with bonded fiberglass meshApplication: embedded in the base coat, it improves the protection and mechanical resistance of the corners, accelerate the works, because the fiberglass mesh is not necessary to be folded over the cornerType: ALU corner with 7+7 cm,10+10 cm or 10+15 cm wide fiberglass mesh
Type Available Code
THERMOMASTER® ALU-L 7+7 2.5 m × 50 pcs=125 m/bundle 0105-07070000THERMOMASTER® ALU 10+10 2.5 m × 50 pcs=125 m/bundle 0105-10100000THERMOMASTER® ALU 10+15 2.5 m × 50 pcs=125 m/bundle 0105-10150000
Material: made of PVC with bonded fiberglass meshApplication: embedded in the base coat, it improves the protection and mechanical resistance of the corners, accelerate the works, because the fiberglass mesh is not necessary to be folded over the corner. Type: PVC corner with 10+10cm or 10+15cm wide fiberglass mesh
Type Packaging Code
THERMOMASTER® PVC 10+10 2.5 m × 50 pcs=125 m/bundle 0107-10100000THERMOMASTER® PVC 10+15 2.5 m × 50 pcs=125 m/bundle 0107-10150000
THERMAL INSULATION SYSTEM14 MASTERPLAST GROUP INTERNATIONAL
PVC-B balcony profile with mesh
Material: made of PVC with alkali-resistant fiberglass meshApplication: fixed at the lower edges of balcony slabs, it prevents the water from flowing back, that could cause frost damages.
Length Packaging Code
2.5 m 2.5 m × 20 pcs=50 m/bundle 0109-00250000
W-PROF Connecting profile to frames
Material: hard PVC profile with flexible, watertight, self-adhesive stripApplication: Self-adhesive PVC-profile with sealing lips including fibre mesh for exact connections to soffits with insulation systems, sealing lips and movement joint. Minimum fixing temperature: +5 °C.
Length Packaging Code
2.5 m 2.5 m × 20 pcs = 50 m/bundle 0112-00250000
Material: polyamide sleeve with plastic nail strengthened with fibreglass.Application: for mechanical fixing of the thermal insulation boardsQuantity: according to the installation guidline (4 – 6 – 8 – 12 pcs/m2)Sizes: sleeve diameter: Ø8mm, lengths of anchor: 75 – 95 – 115 – 135 – 155 mm Tension load in concrete and solid brick (planning value): 0.27 kN, depth of anchoring: 25 mm Tension load in hollow brick (planning value): 0.15 kN, depth of fix depth of anchoring: 35 mm
Length Packaging Code
75 mm 200 pcs/box 0114-00075000 95 mm 200 pcs/box 0114-00095000115 mm 200 pcs/box 0114-00115000135 mm 200 pcs/box 0114-00135000155 mm 200 pcs/box 0114-00155000175 mm 200 pcs/box 0114-00175000
IDK-T anchor
THERMAL INSULATION SYSTEM15MASTERPLAST GROUP INTERNATIONAL
Polyamide sleeve, coated steel nail with polyamide capApplication: for mechanical fixing of the thermal insulation boardsQuantity: according to the installation guidline (4 – 6 – 8 – 12 pcs/m2)Sizes: sleeve diameter: Ø8 mm, lengths of anchor: 75 – 95 – 115 – 135 – 155 – 175 – 195 – 215 – 235 – 255 – 275 – 295 mmTension load in concrete and solid brick (planning value): 0.27 kN, depth of anchoring: 25 mm Tension load in hollow brick (planning value): 0.15 kN, depth of fix depth of anchoring: 35 mm
Length Packaging Code
115 mm 200 pcs/box 0114-10115000135 mm 200 pcs/box 0114-10135000155 mm 200 pcs/box 0114-10155000175 mm 100 pcs/box 0114-10175000195 mm 100 pcs/box 0114-10195000215 mm 100 pcs/box 0114-10215000235 mm 100 pcs/box 0114-10235000
TID-T anchor
Material: PlasticApplication: it ensures the proper lengthening of socle profiles
Width Packaging Code
30 mm 100 pcs/box 0111-03000000
Profile connector
Material: plasticApplication: it ensures the levelleing of uneven surface under the socle profile.Marking: 3 mm – green, 5 mm – yellow, 10 mm – light blue
With Packaging Code
3 mm 100 pcs/box 0112-03000000 5 mm 100 pcs/box 0112-0500000010 mm 100 pcs/box 0112-10000000
plastic spacer for socle profiles
THERMAL INSULATION SYSTEM16 MASTERPLAST GROUP INTERNATIONAL
Material: AluminumApplication: embedded in the base coat, it improves the protection and mechanical resistance of the corners, but the fiberglass mesh must be folded over at the profile.Length: 2 – 2.5 – 3 m
Type Packaging Code
MASTERPROFIL® ALU 12 × 24 2 m 2 m × 50 pcs=100 m/bundle 0104-12200100MASTERPROFIL® ALU 12 × 24 2.5 m 2.5 m × 50 pcs=125 m/bundle 0104-12250125MASTERPROFIL® ALU 12 × 24 3 m 3 m × 50 pcs=150 m/bundle 0104-12300150
MASTERPROFIL® ALU 24 × 24 2 m 2 m × 50 pcs=100 m/bundle 0104-24200100MASTERPROFIL® ALU 24 × 24 2.5 m 2.5 m × 50 pcs=125 m/bundle 0104-24250125MASTERPROFIL® ALU 24 × 24 3 m 3 m × 50 pcs=150 m/bundle 0104-24300150
MASTERPROFIL® ALU-L 2 m × 50 pcs=100 m/bundle 0104-20200100MASTERPROFIL® ALU-L 2.5 m × 50 pcs=125 m/bundle 0104-20250125MASTERPROFIL® ALU-L 3 m × 50 pcs=150 m/bundle 0104-20300150
MASTERPROFIL® ALU 135° 2 m × 50 pcs=100 m/bundle 0104-35200100MASTERPROFIL® ALU 135° 2.5 m × 50 pcs=125 m/bundle 0104-35250125MASTERPROFIL® ALU 135° 3 m*50 pcs=150 m/bundle 0104-35300150
ALU corner bead for jointing
Edge protection PVC profile
PVC Arch form profile
Material: PVCApplication: embedded in the base coat, it improves the protection and mechanical resistance of the corners, but the fiberglass mesh must be folded over at the profile.
Type Packaging Code
MASTERPROFIL® PVC 2.5 m 2.5 m × 20 pcs=50 m/bundle 0106-00250000
Material: PVCApplication: embedded in the base coat, it improves the protection and mechanical resistance of curved edges (e.g. arches).
Length Available Code
2.5 m 2.5 m × 20 pcs=50 m/bundle 0108-00250000
THERMAL INSULATION SYSTEM17MASTERPLAST GROUP INTERNATIONAL
Material: AluminumApplication: fixed at the lower edges of balcony slabs or above windows, it prevents the water from flowing back, that could cause frost damages
Type Packaging Code
9011 2.5 m × 20 pcs/bundle 0109-19011000
9011 – Water drip alu profile
9011
Material: PVC, with alkali-resistant fiberglass meshApplication: Corner profile in PVC on roll with bonded glassfibre mesh The folding line allows corner executions of different angels (e.g. 135°). The roll length of 50 m allows joint free lining. Borders of different win-dow sizes can be done without waste.Advantage: easy-to-use due to the rolled packaging, universally appli-cable to most of the wall corner angles.
Type Packaging Code
3752 50 m/roll 0108-13752000
3752 – PVC corner profile with folding line, with mesh
THERMAL INSULATION SYSTEM18 MASTERPLAST GROUP INTERNATIONAL
Material: PVC, with flexible tapes in the middle and alkali-resistant fiberglass meshApplication: Embedded in the base coat for covering of expansion joints. Only for vertical application!
Type Available Code
3035 2.5 m/pcs 0121-13035000
3035 – Expansion joint PVC profile
Material: Polypropylene sleeve with steel nail Application: For the fastening of e.g. socle profile, UD profile in the floor, ceiling or wall. Sizes: sleeve diameter: Ø6 mm, with different lengths (40 – 60 – 80 mm).Rules of installation: Anchorage depth: 35 mm in solid brick or concrete, 45 mm in hollow brick (cavity brick),
Type: Available: Code
6 × 40 200 pcs/box 0717-64002000 6 × 60 200 pcs/box 0717-66002000 6 × 80 100 pcs/box 0717-68001000
PLUG dowel
19MASTERPLAST GROUP INTERNATIONAL
For further information and downloads, please visit to our website
www.masterplastgroup.com
Notes
MASTERPLAST Group Zrt.8143 Sárszentmihály, Árpád u. 1/a, HungaryPhone: +36-22-801-300, Fax.: +36-22-801-382 E-mail: [email protected]
MASTERPLAST Kft.8143 Sárszentmihály, Árpád u. 1/a., HungaryPhone: +36-22-801-300Fax: +36-22-801-382E-mail: [email protected]
MASTERPLAST România s.r.l.410605 Oradea, Şos. Borşului, nr. 45, RomaniaPhone: +40-259-465-456, Fax: +40-259-435-134E-mail: [email protected]
Î.C.S. MASTERPLAST CONSTRUCT S.R.L.2019, şos. Munceşti, nr.799/3, Chişinău, Republica MoldovaPhone / Fax: +373-22-524-148Phone: +373-69-314-042E-mail: [email protected]
MASTERPLAST YU d.o.o.24000 Subotica, Bodrogvari Ferenc 172, SerbiaPhone: +381- 24-625-825 Fax: +381-24-625-804E-mail: [email protected]
MASTERPLAST d.o.o.31304 Duboševica, Trg Hrvatske Mladeži 2, CroatiaPhone: +385-31-736-512; Fax: +38-5-31-736-513E-mail: [email protected]
MASTER PLAST s.r.o925 21 Sládkovičovo, Veľkoúľanská cesta 1339, SlovakiaPhone: +421-31-784-2181Fax: +421-31-784-2180E-mail: [email protected]
MASTER PLAST PLUS s.r.o.19600 Praha 9-Treboradice, Za tratí 197, Czech RepublicPhone: +42-0-286-850-565, Fax: +42-0-286-850-386E-mail: [email protected]
MASTERPLAST SP. z o.o.Ul. Kolejowa 23, 62-090 Rokietnica, PolandPhone: +48-61-896-35-58/59; +48-61-816-19-97;Fax. +48-61-814-11-79E-mail: [email protected]
MASTERPLAST DeutschlandProduktions- und Vertriebs GmbH39114 Magdeburg, Breite Str. 6f, Germany04519 Rackwitz, Kömmlitzer Str. 13, GermanyPhone: +49-0-34294-84662Fax: +49-0-34294-84663E-mail: [email protected]
MASTERPLAST Ukraina T.O.B.88000 Uzhgorod, Pavlovich u.5., UkrainePhone / Fax: +380-312-656093; +380-312-656073E-mail: [email protected]
MASTERPLAST Bulgaria EOOD1532 Sofia, MSK Kazichene, BulgariaPhone / Fax: +359-2-978-9791; +359-2-978-9764E-mail: [email protected]
Doo MASTERPLAST6250, Kičevo, 11 Septemvri 43, MacedoniaPhone: +389-45-223-766;Fax: +389-45-224-804E-mail: [email protected]
MASTERPLAST KO SHPK10000 Pristina, Rr. Drini i bardh , KosovoPhone: +377-44-250-877; +381-63-555-074E-mail: [email protected]
d.o.o. MASTERPLAST MONT85000 Bar, Jovana Tomaševića G-9, MontenegroPhone: +382-85-353-544; +382-69-657-131;Fax: +382-85-353-544E-mail: [email protected]
MASTERPLAST ÖSTERREICHProduktions- & Vertriebs GmbH3021 Pressbaum, Hauptstraße 119-5/4, AustriaPhone/ Fax: +43-0-2233-52244Mobile: +43-(0)676 - 710 80 82E-mail: [email protected]
MASTERPLAST ALB Sh.p.kTirane Llagja Ali Demi Kruga Shemsije Haka, AlbaniaE-mail: [email protected]
MASTERPLAST IGMIN D.O.O.78000 Banja Luka, Tunjice bb., Bosna i HercegovinaPhone: +387-51-386-486,
+387-51-386-437Fax: +387-51-388-966E-mail: [email protected]
MASTERPLAST China200433 Shanghai, Rm 1305, No. 2158 Siping Road, Fuqing Guoding Building, Yangpu District, ChinaPhone: +86 21 5506 2799Phone/Fax: +86 21 55063899E-mail: [email protected]