this article and any supplementary material should be cited as follows: lindner hy, langius-eklöf...
TRANSCRIPT
![Page 1: This article and any supplementary material should be cited as follows: Lindner HY, Langius-Eklöf A, Hermansson LM. Testretest reliability and rater agreements](https://reader035.vdocument.in/reader035/viewer/2022072013/56649e555503460f94b4cfd1/html5/thumbnails/1.jpg)
This article and any supplementary material should be cited as follows: Lindner HY, Langius-Eklöf A, Hermansson LM. Testretestreliability and rater agreements of Assessment of Capacity for Myoelectric Control version 2.0. J Rehabil Res Dev. 2014;51(4):635–44. http://dx.doi.org/10.1682/JRRD.2013.09.0197
Slideshow ProjectDOI:10.1682/JRRD.2013.09.0197JSP
Test-retest reliability and rater agreements of Assessment of Capacity
for Myoelectric Control version 2.0
Helen Y. N. Lindner, PhD; Ann Langius-Eklöf, PhD; Liselotte M. N. Hermansson, PhD
![Page 2: This article and any supplementary material should be cited as follows: Lindner HY, Langius-Eklöf A, Hermansson LM. Testretest reliability and rater agreements](https://reader035.vdocument.in/reader035/viewer/2022072013/56649e555503460f94b4cfd1/html5/thumbnails/2.jpg)
This article and any supplementary material should be cited as follows: Lindner HY, Langius-Eklöf A, Hermansson LM. Testretestreliability and rater agreements of Assessment of Capacity for Myoelectric Control version 2.0. J Rehabil Res Dev. 2014;51(4):635–44. http://dx.doi.org/10.1682/JRRD.2013.09.0197
Slideshow ProjectDOI:10.1682/JRRD.2013.09.0197JSP
• Aim– Evaluate test-retest reliability and rater agreements of
Assessment of Capacity for Myoelectric Control (ACMC) version 2.0.
• Relevance– ACMC is an observation-based assessment that
evaluates ability to control myoelectric prosthetic hand in bimanual activities
– Stability of ACMC measures has not been evaluated over time.
![Page 3: This article and any supplementary material should be cited as follows: Lindner HY, Langius-Eklöf A, Hermansson LM. Testretest reliability and rater agreements](https://reader035.vdocument.in/reader035/viewer/2022072013/56649e555503460f94b4cfd1/html5/thumbnails/3.jpg)
This article and any supplementary material should be cited as follows: Lindner HY, Langius-Eklöf A, Hermansson LM. Testretestreliability and rater agreements of Assessment of Capacity for Myoelectric Control version 2.0. J Rehabil Res Dev. 2014;51(4):635–44. http://dx.doi.org/10.1682/JRRD.2013.09.0197
Slideshow ProjectDOI:10.1682/JRRD.2013.09.0197JSP
Method
• Upper-limb prosthesis users:– Performed standardized activity twice, 2 to 5 wk apart.
• Activity performances were:– Video recorded.– Assessed by 2 ACMC raters.
• Data were analyzed by:– Weighted kappa.– Intraclass correlation coefficient (ICC).– Bland-Altman.
![Page 4: This article and any supplementary material should be cited as follows: Lindner HY, Langius-Eklöf A, Hermansson LM. Testretest reliability and rater agreements](https://reader035.vdocument.in/reader035/viewer/2022072013/56649e555503460f94b4cfd1/html5/thumbnails/4.jpg)
This article and any supplementary material should be cited as follows: Lindner HY, Langius-Eklöf A, Hermansson LM. Testretestreliability and rater agreements of Assessment of Capacity for Myoelectric Control version 2.0. J Rehabil Res Dev. 2014;51(4):635–44. http://dx.doi.org/10.1682/JRRD.2013.09.0197
Slideshow ProjectDOI:10.1682/JRRD.2013.09.0197JSP
Results• Test-retest reliability– Weighted kappa: fair to excellent. – ICC: 0.94.– Bland-Altman: 1 user outside limits of agreement.– Minimal detectable change (MDC):0.55 logits (1 rater)
and 0.69 logits (2 raters). • Interrater reliability– Weighted kappa agreements: fair to excellent.– ICC: 0.95 (test) and 0.92 (retest).
• Intrarater agreement– Excellent.
![Page 5: This article and any supplementary material should be cited as follows: Lindner HY, Langius-Eklöf A, Hermansson LM. Testretest reliability and rater agreements](https://reader035.vdocument.in/reader035/viewer/2022072013/56649e555503460f94b4cfd1/html5/thumbnails/5.jpg)
This article and any supplementary material should be cited as follows: Lindner HY, Langius-Eklöf A, Hermansson LM. Testretestreliability and rater agreements of Assessment of Capacity for Myoelectric Control version 2.0. J Rehabil Res Dev. 2014;51(4):635–44. http://dx.doi.org/10.1682/JRRD.2013.09.0197
Slideshow ProjectDOI:10.1682/JRRD.2013.09.0197JSP
Conclusion
• Evidence regarding stability of ACMC version 2.0 measures over time is satisfactory.
• MDC value can be clinically useful. • Further research is needed to determine:– Minimal clinically important difference.– Responsiveness of ACMC.