tile replacement mount€¦ · insert the grade-8 serrated flange bolt into the bottom of the post....

8
Tile Replacement Mount Elevated Water Seal Technology ® For use with Flat, S, & W shaped tiles Installation Instructions

Upload: others

Post on 08-Apr-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Tile Replacement Mount€¦ · Insert the grade-8 serrated flange bolt into the bottom of the post. Slide post into base plate channel. Line up post with the hole in the tile replacement

Tile Replacement Mount Elevated Water Seal Technology®

For use with Flat, S, & W shaped tiles

Installation Instructions

Page 2: Tile Replacement Mount€¦ · Insert the grade-8 serrated flange bolt into the bottom of the post. Slide post into base plate channel. Line up post with the hole in the tile replacement

BI 7.2.3-40 Dec-2019, Rev 12

Locate and remove the tile that will be replaced by the tile replacement flashing. Remove tile to the left of and above the mount location. Locate rafter and mark center. Measure 83/4" up from bottom of the adjacent tiles and mark the location with a horizontal line across rafter.

2 31

Align the base plate over rafter so the lag holes line up with the rafter line and horizontal line aligns with the post groove. The orientation of the base plate can be flipped east-west for post location versatility of up to 121/4". Mark location of lag holes on the roof.

Drill two pilot holes using 1/8" bit to a depth of 23/4". Be sure lags go into center of rafter for strongest attachment. Pilot holes reduce rafter splitting. Fill pilot holes with appropriate sealant and align lag holes over the pilot holes.

Waterproof at underlayment level according to roofing manufacturer instructions and Tile Roofing Institute Guidelines. Alternative flashing methods may be approved by the AHJ at their discretion.

6

7

4

Insert the grade-8 serrated flange bolt into the bottom of the post. Slide post into base plate channel. Line up post with the hole in the tile replacement flashing. Leave loose for adjustments.

Place the tile replacement flashing over the post and mount, allowing flashing to interlock with surrounding tiles properly. Secure the post by tightening it down using a pair of channel lock pliers. Replace surrounding tiles.

5

Use T-30 Torx bit and impact gun to secure mount into rafter with provided hardware.

Instructions: QMTR - Tile Replacement MountInstallation Tools Required: stud finder, tape measure, utility knife, drill with 1/8" bit, impact gun with T-30 Torx bit, channel lock pliers, caulking gun, appropriate sealant compatible with EPDM rubber and roofing materials, roofing bar, and hand broom.

NOTE: Installation method is the same for all tile replacement flashing profiles.

1

WARNING: Quick Mount PV products are NOT designed and should NOT be used for anchoring fall protection equipment. CAUTION: Prior to installation, check that proper screw embedment will be achieved for the necessary site load and roofing configurations.

8

Apply a bead of sealant where the post meets the flashing. Slip the EPDM collar over the post and onto the flashing.

Page 3: Tile Replacement Mount€¦ · Insert the grade-8 serrated flange bolt into the bottom of the post. Slide post into base plate channel. Line up post with the hole in the tile replacement

BI 7.2.3-40 Dec-2019, Rev 12

Three-course method flashing on all four sides.

Option 1.

Additional Installation Notes - Tile Replacement Mount

Flashing Tile Roofs in Florida

Optional Methods for Securing Top Flashing

In the State of Florida tile roofs require that the sub-flashing must be flashed ON ALL FOUR SIDES per the TRI/FRSA Florida High Wind Concrete and Clay Tile Installation Manual. For more information, check out Quick Mount PV's Waterproofing Tile Roof Mount sub-flashing: Three-Course Method instructions. Alternative flashing methods may be approved by the AHJ at their discretion.

For replacement flashings susceptible to movement, additional measures may be taken to secure the replacement flashing flush to the roof.

OPTION 1 - Using a pair of tin snips, snip the bottom lip on the right side of the replacement flashing approximately 3/4" inch from the edge and bend the tab under the adjacent tile to help keep the replacement flashing flush to the roof.

OPTION 2 - Adhere flashing to adjacent tile using roofing adhesive compatible with contacted materials and environmental conditions, according to the TRI Guidelines (see sections MC-21 & MC-24).

Page 4: Tile Replacement Mount€¦ · Insert the grade-8 serrated flange bolt into the bottom of the post. Slide post into base plate channel. Line up post with the hole in the tile replacement

BI 7.2.3-40 Dec-2019, Rev 122

1

2

3

4

ITEM NO. DESCRIPTION QTY.

1 FLASHING, .040" X 12" X 7.5", SHEET, 5052-H32, MILL 1

2 TILE REPLACEMENT BASE, 8.125", 6061-T6, MILL 1

3 WASHER, SEALING, 5/16" ID X 3/4" OD, EPDM BONDED SS 2

4 STRUCTURAL SCREW, QMPV, BUTTON HEAD, 5/16" X 4", T-30, STEEL, COATED 2

8DO NOT SCALE DRAWING

SHEET 1 OF 2

RAD

SCALE: 1:2 WEIGHT:

REV

ASIZE

TITLE:

DATE:

DRAWN BY:DIMENSIONS ARE IN INCHESTOLERANCES:FRACTIONAL 1/8TWO PLACE DECIMAL .19THREE PLACE DECIMAL .094

PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF QUICK MOUNT PV. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF QUICK MOUNT PV IS PROHIBITED. COPYRIGHT © 2019 QUICK MOUNT PV

5 4 3 2 1

UNLESS OTHERWISE SPECIFIED:

1.52

QMTR-BM: TILE REPLACEMENT, BASE MOUNT

4/5/2019

6.125

SLIDE POST ALONG CHANNEL TO DESIRED LOCATION

8.13

3.44

1.94

2.438

SCALE 1:5

RACKING NOT INCLUDED

3.216

3.25 MIN4.50 MAX

1.375

TILE REPLACEMENT FLASHING,POST, AND HARDWARESOLD SEPARATELY

(QMTR-F3.25, QMTR-W4, QMTR-S3.25)

WEST ORIENTATION

12.00

7.50

THIS EDGE TOWARDS ROOF RIDGE

EAST ORIENTATION

8DO NOT SCALE DRAWING

SHEET 2 OF 2

RAD

SCALE: 1:4 WEIGHT:

REV

ASIZE

TITLE:

DATE:

DRAWN BY:DIMENSIONS ARE IN INCHESTOLERANCES:FRACTIONAL 1/8TWO PLACE DECIMAL .19THREE PLACE DECIMAL .094

PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF QUICK MOUNT PV. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF QUICK MOUNT PV IS PROHIBITED. COPYRIGHT © 2019 QUICK MOUNT PV

5 4 3 2 1

UNLESS OTHERWISE SPECIFIED:

1.52

QMTR-BM: TILE REPLACEMENT, BASE MOUNT

4/5/2019

Page 5: Tile Replacement Mount€¦ · Insert the grade-8 serrated flange bolt into the bottom of the post. Slide post into base plate channel. Line up post with the hole in the tile replacement

BI 7.2.3-40 Dec-2019, Rev 123

123

456RA

CKI

NG

NO

T IN

CLU

DED

THIS

ED

GE

TOW

ARD

S RO

OF

RID

GE

BASE

MO

UNT

SOLD

SE

RARA

TELY

(QM

TR-B

M)

AV

AIL

ABL

E IN

MIL

L, A

ND

BLA

CK

FIN

ISHE

S

ITEM

N

O.

DES

CRI

PTIO

NQ

TY.

1C

AP

SCRE

W, S

ERRA

TED

FLA

NG

E, H

EX H

EAD

, 5/

16"-1

8 X

1" U

NC

-2A

, GRA

DE

8, Z

INC

1

2PO

ST, 1

-1/4

" OD

X 3

-1/4

", 60

63-T

5/60

63-T

6,

MIL

L1

3W

ASH

ER, S

EALI

NG

, 5/

16" I

D X

1-1

/4" O

D,

EPD

M B

ON

DED

SS

1

4FL

ASH

ING

, REP

LAC

EMEN

T TIL

E, F

LAT,

1"

CO

NE,

ALU

MIN

UM, M

ILL

1

5C

OLL

AR,

CO

UNTE

R FL

ASH

ING

, 1-1

/4" I

D

EPD

M1

6C

AP

SCRE

W, H

EX H

EAD

, 5/1

6"-1

8 X

1" U

NC

-2A

, NYL

ON

PA

TCH,

W/C

APT

IVE

WA

SHER

, 1"

OD

, 18-

8 SS

1 7D

O N

OT

SCA

LE D

RAW

ING

SHEE

T 1 O

F 1

RAD

SCA

LE: 1

:4W

EIG

HT:

REV

ASIZE

TITLE

:

DA

TE:

DRA

WN

BY:

DIM

ENSI

ON

S A

RE IN

INC

HES

TOLE

RAN

CES

:FR

AC

TION

AL

1/8

TWO

PLA

CE

DEC

IMA

L

.19

THRE

E PL

AC

E D

ECIM

AL

.0

94PR

OPR

IETA

RY A

ND

CO

NFI

DEN

TIAL

THE

INFO

RMA

TION

CO

NTA

INED

IN T

HIS

DRA

WIN

G IS

THE

SO

LE P

ROPE

RTY

OF

QUI

CK

MO

UNT

PV.

AN

Y RE

PRO

DUC

TION

IN P

ART

OR

AS

A W

HOLE

WITH

OUT

THE

W

RITT

EN P

ERM

ISSI

ON

OF

QUI

CK

MO

UNT

PV IS

PRO

HIBI

TED

. C

OPY

RIG

HT ©

201

9 Q

UIC

K M

OUN

T PV

54

32

1

UNLE

SS O

THER

WIS

E SP

ECIF

IED

:

1.23

QM

TR-F

3.25

: TIL

E RE

PLA

CEM

ENT,

FL

AT

TILE,

3-1

/4" P

OST

6/6/

2019

Page 6: Tile Replacement Mount€¦ · Insert the grade-8 serrated flange bolt into the bottom of the post. Slide post into base plate channel. Line up post with the hole in the tile replacement

BI 7.2.3-40 Dec-2019, Rev 124

2 1

5

3

6RA

CKI

NG

NO

T IN

CLU

DED

4

BASE

MO

UNT

ASS

EMBL

Y SO

LD

SEPA

RATE

LY (Q

MTR

-BM

)

THIS

ED

GE

TOW

ARD

S RO

OF

RID

GE

AV

AIL

ABL

E IN

MIL

L, A

ND

BLA

CK

FIN

ISHE

S

ITEM

N

O.

DES

CRI

PTIO

NQ

TY.

1C

AP

SCRE

W, S

ERRA

TED

FLA

NG

E, H

EX H

EAD

, 5/

16"-1

8 X

1" U

NC

-2A

, GRA

DE

8, Z

INC

1

2PO

ST, 1

.25"

OD

X 4

", 60

63-T

5/60

63-T

6, M

ILL

1

3W

ASH

ER, S

EALI

NG

, 5/

16" I

D X

1-1

/4" O

D,

EPD

M B

ON

DED

SS

1

4FL

ASH

ING

, REP

LAC

EMEN

T TIL

E, W

-TIL

E, .6

25"

CO

NE,

ALU

MIN

UM, M

ILL

1

5C

OLL

AR,

CO

UNTE

R FL

ASH

ING

, 1-1

/4" I

D

EPD

M1

6C

AP

SCRE

W, H

EX H

EAD

, 5/1

6"-1

8 X

1" U

NC

-2A

, NYL

ON

PA

TCH,

W/C

APT

IVE

WA

SHER

, 1"

OD

, 18-

8 SS

1 7D

O N

OT

SCA

LE D

RAW

ING

SHEE

T 1 O

F 1

RAD

SCA

LE: 1

:5W

EIG

HT:

REV

ASIZE

TITLE

:

DA

TE:

DRA

WN

BY:

DIM

ENSI

ON

S A

RE IN

INC

HES

TOLE

RAN

CES

:FR

AC

TION

AL

1/8

TWO

PLA

CE

DEC

IMA

L

.19

THRE

E PL

AC

E D

ECIM

AL

.0

94PR

OPR

IETA

RY A

ND

CO

NFI

DEN

TIAL

THE

INFO

RMA

TION

CO

NTA

INED

IN T

HIS

DRA

WIN

G IS

THE

SO

LE P

ROPE

RTY

OF

QUI

CK

MO

UNT

PV.

AN

Y RE

PRO

DUC

TION

IN P

ART

OR

AS

A W

HOLE

WITH

OUT

THE

W

RITT

EN P

ERM

ISSI

ON

OF

QUI

CK

MO

UNT

PV IS

PRO

HIBI

TED

. C

OPY

RIG

HT ©

201

9 Q

UIC

K M

OUN

T PV

54

32

1

UNLE

SS O

THER

WIS

E SP

ECIF

IED

:

1.26

QM

TR-W

4: T

ILE

REPL

AC

EMEN

T,

W-T

ILE,

4" P

OST 6/

6/20

19

Page 7: Tile Replacement Mount€¦ · Insert the grade-8 serrated flange bolt into the bottom of the post. Slide post into base plate channel. Line up post with the hole in the tile replacement

BI 7.2.3-40 Dec-2019, Rev 12

2 1

5

3

RAC

KIN

G N

OT

INC

LUD

ED

4

THIS

ED

GE

TOW

ARD

S RO

OF

RID

GE

BASE

MO

UNT

ASS

EMBL

Y SO

LD

SEPA

RATE

LY (Q

MTR

-BM

)

6

AV

AIL

ABL

E IN

MIL

L, A

ND

BLA

CK

FIN

ISHE

S

ITEM

N

O.

DES

CRI

PTIO

NQ

TY.

1C

AP

SCRE

W, S

ERRA

TED

FLA

NG

E, H

EX H

EAD

, 5/

16"-1

8 X

1" U

NC

-2A

, GRA

DE

8, Z

INC

1

2PO

ST, 1

-1/4

" OD

X 3

-1/4

", 60

63-T

5/60

63-T

6,

MIL

L1

3W

ASH

ER, S

EALI

NG

, 5/

16" I

D X

1-1

/4" O

D,

EPD

M B

ON

DED

SS

1

4FL

ASH

ING

, REP

LAC

EMEN

T TIL

E, S

-TIL

E, .6

25"

CO

NE,

ALU

MIN

UM, M

ILL

1

5C

OLL

AR,

CO

UNTE

R FL

ASH

ING

, 1-1

/4" I

D

EPD

M1

6C

AP

SCRE

W, 5

/16"

-18

X 1"

UN

C-2

A, N

YLO

N

PATC

H, W

/ C

APT

IVE

WA

SHER

, 1"O

D, 1

8-8S

S1 7

DO

NO

T SC

ALE

DRA

WIN

GSH

EET 1

OF

1

RAD

SCA

LE: 1

:5W

EIG

HT:

REV

ASIZE

TITLE

:

DA

TE:

DRA

WN

BY:

DIM

ENSI

ON

S A

RE IN

INC

HES

TOLE

RAN

CES

:FR

AC

TION

AL

1/8

TWO

PLA

CE

DEC

IMA

L

.19

THRE

E PL

AC

E D

ECIM

AL

.0

94PR

OPR

IETA

RY A

ND

CO

NFI

DEN

TIAL

THE

INFO

RMA

TION

CO

NTA

INED

IN T

HIS

DRA

WIN

G IS

THE

SO

LE P

ROPE

RTY

OF

QUI

CK

MO

UNT

PV.

AN

Y RE

PRO

DUC

TION

IN P

ART

OR

AS

A W

HOLE

WITH

OUT

THE

W

RITT

EN P

ERM

ISSI

ON

OF

QUI

CK

MO

UNT

PV IS

PRO

HIBI

TED

. C

OPY

RIG

HT ©

201

9 Q

UIC

K M

OUN

T PV

54

32

1

UNLE

SS O

THER

WIS

E SP

ECIF

IED

:

1.17

QM

TR-S

3.25

: TIL

E RE

PLA

CEM

ENT,

S-

TILE,

3-1

/4" P

OST

6/6/

2019

5

Page 8: Tile Replacement Mount€¦ · Insert the grade-8 serrated flange bolt into the bottom of the post. Slide post into base plate channel. Line up post with the hole in the tile replacement

BI 7.2.3-40 Dec-2019, Rev 12

925-478-8269 | www.quickmountpv.com | [email protected]

2700 Mitchell Dr. | Walnut Creek, CA 94598

©2019 by Quick Mount PV. All rights reserved.