toetac 10° xpressaz621074.vo.msecnd.net/syk-mobile-content-cdn/global...stryker does not dispense...

2
ToeTac ® 10° Xpress Hammertoe fixation system

Upload: others

Post on 24-Aug-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ToeTac 10° Xpressaz621074.vo.msecnd.net/syk-mobile-content-cdn/global...Stryker does not dispense medical advice and recommends that surgeons be trained in the use of any particular

ToeTac® 10° XpressHammertoe fixation system

Page 2: ToeTac 10° Xpressaz621074.vo.msecnd.net/syk-mobile-content-cdn/global...Stryker does not dispense medical advice and recommends that surgeons be trained in the use of any particular

Includes unique, sterile, cup and cone reamers designed for PIP joint preparation

Compact kit includes all instruments needs for procedure

Sterile, single-use kits may reduce the risk of cross-contamination and post-operative infection, improving patient safety1

10° angulation

Biocompatible, non-resorbable polymer

Radiolucent implant allows for visualization of the fusion site

ToeTac 10° XpressHammertoe fixation system

Joint preparation

Angled

PEEK

Sterile

A surgeon must always rely on his or her own professional clinical judgment when deciding whether to use a particular product when treating a particular patient. Stryker does not dispense medical advice and recommends that surgeons be trained in the use of any particular product before using it in surgery. The information presented is intended to demonstrate the breadth of Stryker product offerings. A surgeon must always refer to the package insert, product label and/or instructions for use before using any Stryker product. Products may not be available in all markets because product availability is subject to the regulatory and/or medical practices in individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area. Stryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks: Stryker, ToeTac. All other trademarks are trademarks of their respective owners or holders.

This document is only approved for use in the USA.

Content ID: TTX-SS-3, 08-2017 Copyright © 2017 Stryker

References1. Siegel, Geoffrey, MD, et. al. Cost analysis and surgical site infection rates in total knee arthroplasty comparing traditional vs. single-use instrumentation. The Journal of

Arthroplasty 30 (2015) 2271-2274.

Visit footankle.stryker.com or email us at [email protected].

Manufacturer:Stryker GmbHBohnackerweg 1 2545 Selzach, Switzerland

stryker.com

Foot & Ankle

Reamers Proximal and middle phalanx reamers.

Driver Novel driver concept ensures proper seating of implant.

Cannulated Tap Tap is laser marked to

ensure the proper depth has been reached.

Cannulated Drill Bit 2.7mm, 3.2mm or 3.7mm AO Quick Connect drill bits with laser marks for accuracy.

ToeTac 10 degree angled PEEK implant available in three sizes.

K-wire1.1mm with double-ended trocar tip.

Job # 0720_2017, Proof 6, Priscilla, 8/30/2017