training from 220 kv substastion
DESCRIPTION
Training From 220 Kv SubstastionTRANSCRIPT
![Page 1: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/1.jpg)
A Summer Training Presentation on
“Operation and maintenance of EHV equipment and Transmission system”
2013-2014
Presented by:Vikas Jangir
Electrical Engineering
Rajdhani Engineering College Jaipur
Department of ‘Electrical Engineering
![Page 2: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/2.jpg)
Introduction of a substation
Intermediate link between
Generating station & Consumers Important part of T&D Step down high voltages
Sanganer GSS Capacity : 220 kV,132kV,33 kV
![Page 3: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/3.jpg)
220 kv GSS Sanganer• History of GSS.
1. Established in 19812 1981 – Heerapura 132kV was there3 1998 – KTPS 220kv was added4 2002 – Heerapura-I 220kv was added5 2005 – Heerapura-II 220kv added
• Incoming feeders.1 Heerapura I – 220kV
2 KTPS – 220kV
3 Heerapura II -220kV
![Page 4: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/4.jpg)
Outgoing feeders• 132kv lines
1. Mansarovar I 2. Mansarovar –II
3. Balawala
4. Niwai
5. Sitapura
6. chaksu
• 33kv lines
1. Muhana Mandi
2. Malpura
3. Vatika
4. Phagi
5. Sitapura
6. Sanganer
7. Durgapura-I
8. Durgapura-II
• 11kv lines
1. Tejawala
2. Industrial
3. Pream Nagar
4. Muhana
![Page 5: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/5.jpg)
Single line diagram
![Page 6: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/6.jpg)
GSS
![Page 7: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/7.jpg)
Classification of substation. • Basis of Nature of Duties
1. Step-Up or primary Substations
2. Primary Grid Substations
3. Step-Down or Distribution Substations
• Basis of Importance
1. Grid Substations
2. Town Substations
• Basis of Service Rendered
1. Transformer Substations
2. Switching Substations
3. Converting Substations
![Page 8: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/8.jpg)
Classification on the Basis of Operating Voltage
1. High Voltage Substations
2. Extra High Voltage Substations
3. Ultra High Voltage Substations
Classification on the Basis of Design
1. Indoor Type Substations
2. Outdoor Type Substations
![Page 9: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/9.jpg)
Equipment For Substation• Lightning Arresters• Main Bus-Bars• Wave Trap• Switchgear• Power Transformer• Instruments Transformers• Capacitor voltage transformer• Isolators • Circuit Breakers • Insulators • Fuses• Protective Relays• Station Insulators• Batteries
![Page 10: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/10.jpg)
Lightning arrester• Protective device• Equipment use power poles and towers, power
transformers, circuit breakers, bus structures, and steel superstructures in substations
![Page 11: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/11.jpg)
Wave trapper • Trap signals and send it to PLCC control Room• For information purpose
![Page 12: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/12.jpg)
Bus-bars• Carry electrical supply• Maximum load
![Page 13: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/13.jpg)
Switchgears • Controlling equipment• Protecting equipment
1. Equipment • Air break Switches, Oil Switches,Isolators,Circuit breaker• Earthing Switch
![Page 14: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/14.jpg)
Air switch breaker Isolators
![Page 15: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/15.jpg)
Circuit breakers• Used to Close or open
electrical circuit • -It cab be operated manually
or automatically
Classification of C.B1. Water circuit breaker
2. Air circuit breaker
3. Air blast circuit breaker
4. Sulphur-hexa-fluoride circuit breaker
5. Vacuum circuit breaker
![Page 16: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/16.jpg)
Power transformer
![Page 17: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/17.jpg)
Types of Transformer
• Power transformer• Current transformer• Potential transformer• Capacitance voltage transformer• Distribution transformer
faults in transformer• Internal faults• External faults
![Page 18: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/18.jpg)
Current transformer • Reduced high voltage in
a fixed voltage and measurements purpose also
Potential transformer• Measurement of electric
currents and protective relays
![Page 19: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/19.jpg)
Faults in transformerExternal faults• Must be disconnected• Not allowed to operate for
long time• Failure of coolant
Protection• Buchholz protection• Overheating protection • Cooling fans
Internal faults• Short circuit in windings• Fire inside transformer • Over heating
Protection• Fire protection system• Protection against
magnetizing inrush current
![Page 20: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/20.jpg)
Cooling in transformer
![Page 21: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/21.jpg)
Fire protection system• N2O2• Nitrogen injection, when control panel receive indication
![Page 22: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/22.jpg)
Substation earthing• Every instrument earthed• Lighting arresters
![Page 23: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/23.jpg)
Control room
Protection
![Page 24: Training From 220 Kv Substastion](https://reader033.vdocument.in/reader033/viewer/2022061503/563dbb45550346aa9aabbc8e/html5/thumbnails/24.jpg)
Battery Room• Very crucial section of GSS as batteries provide power
back up and also DC power for DC signaling of control equipments and fire protection system