tri chlorine generator instruction manual and ......the zodiac tri chlorine generator comes with two...

28
TRi ChloRine GeneRaToR insTRuCTion Manual and WaRRanTy CaRd

Upload: others

Post on 23-Oct-2020

17 views

Category:

Documents


0 download

TRANSCRIPT

  • TRi ChloRine GeneRaToR

    insTRuCTion Manual and WaRRanTy CaRd

  • 1

    Part: Qty: description:

    a. 1 TRiPowerpack

    b. 1 Chlorinegeneratingcell

    c. 1 Powerpackbracket

    d. 2 Reducingbushes

    This KiT ConTains:

  • 1

    WelCoMe To ZodiaC

    CongratulationsonyourpurchaseofaproductfromtheZodiacrangeofpoolcareproducts.Zodiacproductsaredesignedtoletyouspendmoretimeenjoyingyourpoolandlessonmaintenance.

    iMPoRTanT infoRMaTion

    YOUMUSTREADTHISINFORMATIONBEFOREINSTALLATION.ALWAYSREADTHELABELANDOPERATIONMANUALBEFOREUSING.PLEASEKEEPYOURMANUALASITCONTAINSYOURWARRANTY.

  • 2 3

    ZodiaC Believes in safeTy fiRsT

    AtZodiac,wetakesafetyseriously.Alwaysexercisecautionwhenusingelectricalappliancesandfollowtheinstructions.Failuretodosocouldresultinpermanentinjury,electrocutionordrowning.

    GeneRal WaRninGs

    Zodiacsaltwaterchlorinegeneratorsaredesignedfordomesticswimmingpooluseonly.Contraryusecouldaffectperformanceandvoidwarranty.

    Operatingachlorinegeneratorwithoutwaterflowingthroughthecellmaycauseabuildupofflammablegases,resultinginfireorexplosion.

    Keepequipmentoutofreachofchildren.

    Adamagedsupplycordshouldonlybereplacedbythemanufacturer,authorizedserviceagentorelectrician.

    Wheninstallingandusingthiselectricalequipment,alwaysfollowbasicsafetyprecautions.

    Beforeperforminginstallation,disconnectallpower.

    Forswimmingpools,Australianstandardsrecommendaminimumof1PartPerMillion(ppm)offreeavailablechlorinemustbemaintainedatalltimes.

    ServicetoZodiacequipmentshouldonlybecarriedoutbyqualifiedandauthorizedpoolprofessionals.

  • 2 3

    ZodiaC Believes in safeTy fiRsT

    Child safeTy

    Childrenshouldnotbeallowedtooperateorperformmaintenanceonthisproduct.

    Noone,particularlychildren,shouldsit,step,lean,orclimbonanyofyourpool’soperationalsystem.

    Intheinterestsofchildsafety,allcomponentsofapool’soperationalsystemshouldbelocatedatleast3.5metresawayfromthepool.

    eleCTRiCal haZaRd

    Toavoidaccidentalcontactwithlawnmowersandhedgetrimmers,powercordsshouldremainwithinsightandabovegroundatalltimes.

    TheZodiacTRIPowerpackmustnotcomeintocontactwithwaterandmustbeinstalledatleast3.5metresfromtheinsidewallofyourswimmingpool.

    Shouldalackofwaterbedetected,theunit’selectronicflowswitchisdesignedtoturnoffthesystem.Interferingwiththeelectronicflowswitchcouldresultinpersonalinjuryand/ordamagetothecell.

    Onepumpperelectricalsocketonly(noancillaryequipmentshouldbeconnectedtothesameoutlet).

    Thisapplianceisnotintendedforusebypersons(includingchildren)withreducedphysical,sensoryormentalcapabilities,orlackofexperienceandknowledge,unlesstheyhavebeengivensupervisionorinstructionconcerninguseoftheappliancebyapersonresponsiblefortheirsafety.

    Childrenshouldbesupervisedtoensurethattheydonotplaywiththeappliance.

    TheinstallationofthechlorinatorshouldbecarriedoutbyaqualifiedpersoninaccordancewiththeAustralianwiringrulesAS/NZS3000.

    Thechlorinatorpowerpackshouldbelocatedinthecorrectpoolzoneandconnectedtosupplyviaapoweroutletthatisprotectedbyaresidualcurrentdevice(RCD)havingaratedresidualoperatingcurrentnotexceeding30mA.ThepoweroutletshouldhaveadegreeofprotectionsuitableforthepoolzoneEnsurethatequipotentialbondingofallpartsofthepoolinstallationiscarriedout.

  • 4 5

    insTallaTion Guide

    ThefollowingstepswillhelpyougetupandrunningwithyournewZodiacTRiChlorinegenerator.

    PosiTioninG The PoWeR PaCK

    1. Locateasuitablespaceforthepowerpackbracket.Itshouldbeinstallednofurtherthan1.8metresawayfromthecell-ideallyinafiltrationshedorclosetothefiltrationequipment.

    PLEASENOTE:iffixingtoapostitmusthaveawaterproofpanelfitted(behindtheunit),atleast450mmwideand470mmhigh.

    2. Usingscrewsprovided,fastenthebracketsecurelytothewallandpositionthepowerpackonthebracket.Plugintopowerpoint,butdon’tturnonthepower.

    PosiTioninG The ChloRine GeneRaTinG Cell

    PLEASENOTE:Thecellshouldalwaysbethelastdeviceplacedonthewaterpipe(Inthereturnlinetothepool).

    3. Ensurethecellisplacedhorizontally,withtheInletpipeconnectingtothefittingclosesttothecelllead.

    4. Usingscrewbarrelfittings(supplied),attachthecelltothepipe.Ifusing40mmpipe,youwillneedtofitthecellusingthereducingbushes(alsosupplied).

    5. Whenconnectingtheleadfromthepowerpacktothecellmatchupthecorrespondingcoloursandpins,thenfittheendcap.

    (Note:EitherREDwirecanbeconnectedtoeitherREDpinontheelectrode.)

    6. PlugyourpoolpumpintotheoutletsocketinthebottomoftheTRi(thiswillallowtheTRitimertocontrolthefiltrationtimes)

    7. OnceallconnectionsaretogetherpressthemainspowerswitchtoON.

  • 4 5

    naviGaTion BuTTons

    UsethefollowingUIbuttonstoaccessandselectallmenusandcommands:

    on/off

    TurnUIpoweron/off.

    uP/doWn

    Scrollup/downwithincurrentmenutohighlightaspecificmenucommand.

    Menu/BaCK

    Entersintothemainmenu,andusedtogobacktopreviousmenu.

    seleCT/enTeR

    Select/enterscurrenthighlightedmenucommand.Displaythenextrelatedcommandoractivatetheselectedfunction

  • 6 7

    usinG inBuilT CloCK and TiMeRs

    Whenitcomestochlorination,everypoolisdifferent.Togetwhat’srightforyou,youwillneedtosettheunit’sclockandtimers.

    seTTinG The CloCK

    1. Switchpoweron.

    2. Waitforthestart-upsequencetocomplete.

    3. Pressthe buttontoentertheMAINMENU.

    4. Use / buttonsandscrolltoSETCLOCK.

    5. Press .

    6. Use / buttonstosetthehours.

    7. Press tosavethehours.

    8. Usethe / buttonstosettheminutes.

    9. Press tosavetheminutes.

    TRiwillthenreturntotheMAINMENU.

    10.Press toreturntotheoperatingscreen.

    NOTE:Thetimeisdisplayedin24Hourformat

  • 6 7

    TuRninG ChloRine GeneRaTion on

    ThechlorinegenerationoftheTRicanbecontrolledinanumberofways:

    1. Manuallysettoanoutputlevel,withtheoperatingtimesdeterminedbyanexternaltimer.

    2. Usingthein-builttimersontheTRiunit(referto‘TheTimers’)

    3. Usingaconnectiontoanexternalcontroller(referto‘Connectingtoacontroller’).

    Toturnthechlorinegenerationonmanually,presstheON/OFFbutton.Theoutputlevelcanbesetasdescribedin‘SettingtheChlorineOutput.’NOTE:Forsafetyreasons,theTRichlorinegeneratorwillcontinuallydosechlorineforamaximumof30hoursifleftrunningwithno‘OFF’time–unlessconnectedtoenexternalcontroller.Afterthistime

    theTRiwillswitchto‘OFF’.

    The TiMeRs

    TheZodiacTRichlorinegeneratorcomeswithtwoinbuilttimersthatswitchthefiltrationandchlorinationsystemonandoffasrequired.

    Duringswimmingseason,considerrunningthesystemforaround8hoursaday.Thiscanbeincreasedto10hoursduringperiodsofveryhotweather.

    Inwinter,itmayonlybenecessarytorunyourpool’sfiltrationsystemfor4hoursaday.Theseshorterperiodsofactivitywilllengthenthelifeoftheunit’selectrode.

    Forbestyearroundresults,settheunittooperateduringthecoolerhoursoftheearlymorning,eveningorwhenswimmersareusingthepool.

    PRoGRaMMinG The TiMeRs

    Toactivatethetimer,youwillneedtoenterbothanONandOFFtime.IfnoOFFtimeisentered,thechlorinegeneratorwillswitchoffatthedefaulttimeof12:00am(0:00).

    Youwillknowthatavalidtimehasbeenenteredwhena“T”SymbolisdisplayedinthetoprighthandcorneroftheLCDdisplaywhentheunitisdisplayingthe‘operatingscreen’.

    usinG inBuilT CloCK and TiMeRs

  • 8 9

    usinG inBuilT CloCK and TiMeRs

    Toprogramthetimer:

    1. Pressthe button.

    2. Press buttontomovearrowto‘SETTIMERS’.

    3. Press toenterthe‘SETTIMERS’menu.

    4. Press / toselectthetimeryouwishtoset.(Timer1orTimer2)

    5. Press .

    6. Press / tosetthehours(ontime).

    7. Press tosavethehours.

    8. Press / tosettheminutes(ontime).

    9. Press tosavetheminutes.

    10.Press / tosetthehours(offtime).

    11.Press tosavethehours.

    12.Press / tosettheminutes(offtime).

    13.Press tosavetheminutes.

    TRiwillreturntothe‘SETTIMERS’menu.

  • 8 9

    CleaRinG The TiMeRs

    Toclearthetimer:

    1. Pressthe button.

    2. Press / buttontoscrollto‘SETTIMERS’.

    3. Press toenterthe‘SETTIMERS’menu.

    4. Press / toscrollto‘CLEARTIMERS’.

    5. Press .

    Aconfirmationmessagewillappearonthescreen.

    exTeRnal TiMe CloCK

    Attimes,itmaybedesirabletocontrolchlorinegenerationusinganexternaltimeswitch.IfthechlorinegeneratoristurnedON,andtheexternaltimerfailstoswitchthemainspoweroffwithin30hours,theZodiacTRiwillautomaticallystopchlorinatinginordertopreventoverchlorination.

    Tosetthechlorinegeneratortorunfromanexternalclock:

    1. CleartheTimerbyfollowingtheprocedureoutlinedin‘ClearingtheTimers’.

    2. Pressthe buttontoturnthechlorinegeneratoron.

    usinG inBuilT CloCK and TiMeRs

  • 10 11

    seTTinG The ChloRine ouTPuT

    Theamountofchlorinerequiredbyyourpoolisdependentonanumberoffactorsincludingthesizeofthepool,thenumberofusersandtheclimate.

    Outputwillappearasapercentageonthescreenreadout,monitorthelevelaccordingtothereadingovertimewillhelpensureoptimumoutput.

    ForuserswhoupgradetotheTRi-PROmodel,chlorineoutputwillbecontrolledautomatically.

    TosetChlorineOutputlevels:

    1. Pressthe buttontoturnthechlorinegeneratoron.

    2. Pressthe / buttonstosetthedesiredoutputlevel.

    PLEASENOTE:ifusingapoolcoveryouwillneedtoreducethechlorineproductionsubstantially,pleaseuseLOWmodeifyouuseacover.SimplypressLOWbutton.

    ChloRine ouTPuT levels

  • 10 11

    CoRReCT seTTinGs foR youR TRi ConTRolled Pool

    fre

    e

    Ch

    lori

    ne

    (p

    pm

    )

    ph

    To

    tal

    alk

    alin

    ity

    (pp

    m)

    Cal

    ciu

    m

    hard

    ne

    ss

    (pp

    m)

    Cyan

    uri

    c a

    cid

    (p

    pm

    )

    sal

    t l

    eve

    l (p

    pm

    ) s

    en

    sors

    au

    stra

    lian

    sta

    nd

    ard

    1–3

    7.2–7.8

    80–300

    90–300

    30–50

    4000-7000

    ide

    al r

    ead

    ing/

    ran

    ge

    1–3

    7.5

    80–140

    90–300

    504000ppm

    at27ºC**

    To

    in

    cre

    ase

    *

    Add

    chlorine

    orincrease

    outputof

    equipm

    ent

    Addbuffer

    orsodaash

    (sodium

    carbonate)

    Add

    sodium

    bicarbonate

    Add

    calcium

    chloride

    Add

    Cyanuric

    acid

    AddSalt

    To

    de

    cre

    ase

    *

    Add

    muriatic

    acid

    Add

    muriatic

    acidor

    dryacid

    Partially

    drain

    &refillpool

    Partially

    drain

    &refillpool

    Partially

    drain

    &refillpool

    fre

    qu

    en

    cy o

    f te

    stin

    g (i

    n p

    eak

    se

    aso

    n)

    Weekly

    Weekly

    Weekly

    Weekly

    Weekly

    Monthly

    Quarterly

    Co

    RR

    eC

    T s

    eT

    Tin

    Gs

    fo

    R y

    ou

    R T

    Ri

    Co

    nT

    Ro

    ll

    ed

    Po

    ol

  • 12 13

    IfyouuseanautomationorcontrollersystemtocontrolyourpoolyouwillneedtoconfigureyourTRiChlorinegeneratortoallow“communication”betweenthetwo.

    you must set the controller type on the TRi before making the wiring connection.

    seTTinG The ConTRolleR (To be done before making a wiring connection)

    1. SwitchpowertotheTRiuniton.

    2. Waitforthestart-upsequencetocomplete.

    3. Pressthe button.

    4. Pressthe buttontoscrolldownto‘CONTROLLER’.

    5. Press toenterthecontrollermenu.

    6. Press / tohighlightthecontrollerbeingused.

    7. Press tosavethecontrollersetting.

    8. TRiwillreturntothemainmenu.

    9. Press toreturntotheoperatingscreen.

    ConneCTinG To a ConTRolleR

  • 12 13

    aTTenTion Jandy ‘Rev l’ oR laTeR useRs

    ItiscriticalthatthecontrollersettingbesettothecorrectZodiac,JandyorPentaircontrollerdesignation.ThereareanumberofdifferentrevisionslockedintotheTRisoftware.Pleaseseetheusermanualtodeterminethemodeland/orrevisionyouareusing.Iftheincorrectsettingisselected,damagecanbecausedtotheJandyAqualinkControlUnit.

    CauTion When WiRinG To a ConTRolleR

    IMPORTANT

    Wiringofthecontrollershouldbecompletedbyanauthorisedpoolequipmentinstaller.

    Beforeanywiringconnections/disconnectionsensuremainspowerisremovedfromboththecontrollerandtheZodiacTRiunit.

    Whenconnectedtoacontroller,theTRiChlorinegeneratoractsasthe‘slave’-respondingtorequests.Thismeanstimersettingsareignoredandtheoutputsettingscannotbechanged,althoughallother‘menu’functionsarestillaccessible,exceptforLOWandBOOSTmodes.

    WiRinG To a ConTRolleR

    ThefollowinginstructionsshouldbereadinconjunctionwiththeinstallationguideprovidedwiththeController.

    1. Removesilver‘dress’coverbypressinginatthesideswhereindicatedbelowandlift.

    2. Removethetwoscrewswhichattachthelowercovertothemainunit:

    ConneCTinG To a ConTRolleR

  • 14 15

    ConneCTinG To a ConTRolleR

    3. RemovethelowercoverfromtheTRiunit.NOTE:IfusingeitherpHupgradeorPROunit–carefullydisconnecttheribboncablefromtheTRiunit.

    4. RemovethesmallwhitebungclosesttothecentreofthelowerpaneloftheTRiunit.

    5. Threadthecontrollercablethroughthehole(agrommetmaybenecessarydependingonthesizeofthecablebeingused).

    6. Attachacabletietothecontrollercableasshowninthediagram.Thewiringcolourcodesareoutlinedbelow:

    DependingonthemakeoftheController,makethefollowingwiringconnections:

    Polaris eos / Jandy / Zodiac aqualink / aqualink TRi

    Greenwire(0V)to‘0V’terminalontheTRi

    Redwiretothe(+V)‘POS’terminalontheTRi

    Yellow/White(B)wireto‘B’terminalonTRi

    Blackwire(A)to‘A’terminalonTRi

    Pentair intellitouch

    GREENwireto‘B’terminalonTRi

    Redwireto‘POS’terminalonTRi

    Yellowwireto‘A’terminalonTRi

    Blackwireto‘0V’terminalonTRi

  • 14 15

    TesTinG The WiRinG ConneCTion

    OnceaconnectionhasbeenmadebetweentheControllerandtheChlorinegenerator,itwillneedtobetested.

    1. TurnonthepowertotheControllerandtheZodiacTRi.

    2. Ifsuccessful,a‘ ’symbolwillappearinthetoprighthandcornerofthescreenafterabout20seconds.

    3. Ifthecontrollerdoesnotconnect,turnpowerofftoboththedevicesandtryagain.

    veRify The WiRinG ConneCTions

    Toverifytheconnection:

    1. SwitchtheTRiunitonandcheckthecontrollersetting(followinstructionsunder‘SETTINGCONTROLLER’.

    2. Re-testtheconnection. Note:Forsafetyreasons,theZodiacTRirevertstotheOFFsettingifthecommunication

    connectionislost.

    ConneCTion To ConTRolleR foR Pool/sPa CoMBinaTions

    ToconnectaZodiacTRiunittoPoolorSpaValves,youwillneedtomakea“splice”intothecontrollinesfromtheController,locatedinsidethecontrolleritself.

    Forfurtherinformation,consulttheinstallationmanualoftheControllerbeingused.

    ConneCTinG To a ConTRolleR

  • 16 17

    Ifyourpoolhasacover,youshouldsettheoutputlevelto“low”.Thisisalsoknownas“winter”mode.

    Reducingyourchlorineoutputwillhelppreventdamagetoyourpool’scoverandotherequipment.

    Manual seTTinG

    1. ToselectLowmodepress .

    Thiswilldropthechlorineoutputtoaround10%.

    2. ‘Low’willappearonthescreen. Note:LoworWintermodecannotbeselectedwhenTRiisbeing

    controlledbyanexternalcontroller.

    auToMaTiC seTTinG

    TheZodiacTRicanbeconnectedtothevalvesofanautomaticpool/spasystem.

    Whentheinputfromthevalvesissetto‘Low’theTRiwillautomaticallyrevertto‘Low’modeandtheoutputwillbelockedat10%

    Detailsofthewiringconnectionareoutlinedinthe‘‘ConnectiontoAutomaticPool/SpaValve”sectionofthismanual.

    for users who have upgraded to the TRi-ph or TRi-PRo, the automatic ph/aCl control function is disabled when in loW mode.

    seTTinG The Mode To loW: Important If usIng a pool cover

  • 16 17

    Attimesyourpoolmayrequirealargerthannormalapplicationofchlorine.TheBoostfunctionisusedtorapidlyaddchlorine.

    InBOOSTor“Superchlorinate”mode,outputsettingsaretemporarilyoverriddenandthechlorinegeneratorrunsfor24hoursat100%ChlorineProduction.

    In‘TIMER’mode,thecirculationpumpwillrunfor24hours,beforeautomaticallyrevertingtopreviousoutput/timersettings.

    In‘MANUAL’mode,thechlorinegeneratorwillrunat100%foracumulativetotalof24hoursbeforerevertingtothepreviousoutputsetting.

    NOTE:

    The‘BOOST’modecannotbeengagedunderthefollowingcurcumstances:

    1) IftheTRiisinthe‘OFF’operatingmode.Thechlorinatormustbe‘ON’forBOOSTtobeengaged.

    2) IfyouhaveupgradedtotheTRi-PRO

    3) OrfromthefrontpanelwhentheTRiisbeingcontrolledbyanexternalcontroller.

    InmostcasesaBOOSTfunctioncanbesetfromthecontrollermenu.

    Consultyourthirdpartycontrollermanualformoreinformation.

    seTTinG The BoosT Mode

    ToactivatetheBOOSTsetting:

    Pressthe button.

    ‘BOOST’willbedisplayedonthescreenandchlorinegenerationwillcommence.

    The BoosT seTTinG

  • 18 19

    TheZodiacTRichlorinegeneratorautomaticallyprovidesanumberofinbuiltwarningsthatcanhelpidentifyproblemsandoffersolutions.

    ToaccesstheHELPmenu:

    1. Pressthe button.

    2. Usingthe / buttons,scrolltothe‘HELP/DIAG’menu.

    3. Press toenterthe‘HELP/DIAG’menu.

    4. Onceinthe‘HELP/DIAG’menu,usethe / buttonstoscrollto

    theerror/warningthathasbeendisplayed.

    5. Press .

    Anumberofsuggestedsolutionsaremomentarilydisplayed,inorderofpriority.

    Afterdisplaying,theTRiautomaticallyrevertsbacktothe‘HELP/DIAG’menu.

    6. Toexittothedefaultoperatingscreenwait~5seconds

    ORpressthe button.

    helP and TRouBleshooTinG

  • 18 19

    TokeepyourTRiUnitinthebestpossibleconditionitisrecommendedregularmaintenanceshouldbeperformed.

    insPeCTinG and CleaninG The eleCTRode

    InareasthatexperiencecalciumhardnesstheTRielectrodewillbenefitfromcleaning.

    Tocleanyourelectrode:

    1. Switchoffthefilterpumpandchlorinegenerator,closenecessaryvalvesandunplugthecellterminalcap.

    2. Unscrewtheretainingringandremovetheelectrode.Ifcalciumbuildupispresent,immersetheelectrodeincellcleaningsolutionwithoutimmersingtheterminals.

    3. WerecommendusingZodiacSaltChlorinatorCellCleanertocleantheelectrode.Howeveryoucanmixyourownbycarefullyaddingone(1)partofHydrochloric(Muriatic)acidtoten(10)partswater.Strongersolutionswillshortenterminallife.

    4. Allowthecleaningsolutiontodissolvethecalciumdepositsforabout10minutes.DisposeofthecleaningsolutionatanapprovedCouncilDepotandneverintostormwaterorsewagedrains.

    6. Rinsetheelectrodeincleanwaterandre-fittheelectrodeinthecellhousing.

    7. Replacethecellheadandplugassemblyandresetvalvesandswitches.TurnpumpandTRion.

    8. Confirmchlorineoutputandsettingsonthepowerpack.Timersettingswillbeautomaticallyretained.

    MainTenanCe

  • 20 21

    eRRoRs and WaRninGs. WhaT They Mean.

    no floW

    Diagnosis:Insufficientwaterflowinthecell.Thiscouldmeanthecirculationpumphasceasedtofunction,orthefilterneedscleaning.Thechlorineoutputwillbeturnedoffatthistime.

    CheCK salT

    Diagnosis:Saltlevelisbetween3000and4000ppm,dependingonthewatertemperature.

    Alwaysmaintainasaltlevelabove4000ppm.ifyoudon’tknowwhatyoursaltlevelisorhowtotestit,consultyourlocalpoolcareprofessional.

    CheCK PoWeR suPPly

    Diagnosis:Therecouldbeaproblemwiththepowersupply.Turnpoweroffatthepowerpointandconsultyourlocalpoolcareprofessional.

    CleaninG

    Diagnosis:Thecellisintheprocessofreversingpolarity.Waitapproximately5minutesandchlorineproductionshouldresumeasnormal.

  • 20 21

    TRouBleshooTinG

    additional information about this product can be found at zodiac.com.au

    Forfurtherinformationandassistancepleaseconsultyourlocalpoolprofessional.

    Your Local Dealer:

  • 22 23

    express Warranty*ZodiacGroupAustralia Pty Ltd (Zodiac australia)warrants that theZodiacTRiSaltwaterChlorineGeneratorwillbefreefromdefectsinmaterialsandworkmanshipfortheperiodof3yearsfromthedateofpurchase.

    * The warranty applicable to commercial application is limited to 12 months from the date of installation.

    Conditions

    1 Thisexpresswarrantyonly applies if theProducthasbeenpurchasedfromadealerauthorisedbyZodiacAustraliatosupplyit(authorised dealer).

    PurchasefromanAuthorisedDealerensuresthattheproductisagenuineZodiacproduct,thatitistheversiondesignedforAsiaPacificconditions,and that thePurchaserhasaccess toappropriate technicalknowledgeandadvice.

    2 ZodiacAustralia’s liabilityunder thisexpresswarranty is limited, at itsoption,totherepairorreplacementoftheProductorthepaymentofthecostofhavingtheProductrepairedorreplaced.

    3 Thisexpresswarrantydoesnotapplyinthefollowingcircumstances:

    (a)if the Product has not been installed in accordancewithZodiac’sinstallationinstructions;

    (b)iftheProducthasbeenmodifiedotherthanasauthorisedbyZodiacAustraliaorifacomponentparthasbeenreplacedbyapartthatisnotagenuineZodiacproduct;

    (c)if a defect results fromuse of the Product outside recommendedoperatingconditions;or

    (d)if a defect results from damage (including damage to any internalelectronics)causedbyapowersurgeorlightningstrike.

    Zodiac chlorinators are designed and tested in accordance withInternational Standard EN 61000-6-1 immunitymeasurements. Theyaredesignedtotolerateminorfluctuations(2000volts)inpowersupplythatcanbereasonablyexpectedtooccurintheenergygrid.Theywillnottoleratepowersurgesoutsidetheselimitsnorwilltheywithstandlightningstrikes.

    ZodiaC ausTRalia - exPRess WaRRanTy and GuaRanTees

  • 22 23

    ZodiaC ausTRalia - exPRess WaRRanTy and GuaRanTees

    4 Withoutlimiting3above,productssoldbyZodiacAustraliaaredesignedforusewithswimmingpoolwaterbalancedinaccordancewithAustralianStandardAS3633-1989withapHrangeof7.0-7.8.Maximumchlorinereadingsshouldnotexceed4ppm.Wherepoolwaterisnotmaintainedwithintheseparameters,ZodiacAustraliawillnotberesponsibleunderthisexpresswarrantyforanyresultingdamage,includingdamagecausedbycorrosion,scalingorstressloading.

    5 Replacementpartssuppliedunderthisexpresswarrantyarewarrantedtobefreefromdefectsinmaterialsandworkmanshipfortheremainderofthewarrantyperiodorfor12monthsfromthesupplyofthereplacement,whicheverislonger.

    6 WarrantyclaimsrelatingtoreplacementoftheelectrodesforLMseries,Cseries,DuoClearandDserieschlorinatorsaresubjecttothefollowingpro-ratapricingprocedure.ThePurchasermustpayforthereplacementelectrodeaproportionofthecostequaltothatproportionofthewarrantyperiod duringwhich theoriginal electrode functioned effectively. Thewarrantyperiodforthereplacementelectrodeistheremainderofthewarrantyperiodfortheoriginalelectrodeor12monthsfromthesupplyofthereplacement,whicheverislonger.ThePurchasermustpayfullcostforanyreplacementelectrodesafterthefirstreplacement.

    Product warranty registration

    7 PurchasersshouldregistertheirProductsassoonasconvenientlypossibleafterpurchasebycompletingaProductWarrantyRegistrationFormandpostingittoZodiacAustraliaattheaddressshownontheFormorbyregisteringonlineatwww.zodiac.com.au.

    8 Productregistrationmustoccur,andproofofpurchasemustbereceivedbyZodiacAustralia,priortoanywarrantyworkbeingapproved.Whereapplicable,aserialnumber,installationdateandnameofinstallerisrequiredaspartoftheregistrationprocess.

  • 24 25

    ZodiaC ausTRalia - exPRess WaRRanTy and GuaRanTees

    how to make a warranty claim

    9 ThePurchasermusttelephoneoremailZodiacAustraliaCustomerServiceandobtainawarrantyIDnumberforthewarrantyclaim.

    Contactdetailsare:

    Zodiac Group australia Pty ltd 219WoodparkRoadSmithfieldNSW2164

    Customer service Telephone:1800688552Emailaddress:[email protected]

    10ZodiacAustralia reserves the right to determine, in relation to eachwarrantyclaim,whethertheProductshouldbereturnedtotheAuthorisedDealerat theaddresswhere thePurchaserpurchased theProductorwhetherwarrantyservicewillbeprovidedinthefield,repairedataZodiacworkshoporatthepremisesofanauthorizedZodiacwarrantyagent.

    11 IfitisnecessaryforthePurchasertoincurfreightchargesinmakingavalidclaimunderthiswarranty,ZodiacAustraliawillreimbursethePurchaserforchargesreasonablyincurreduponproofofthecharges.

  • 24 25

    ZodiaC ausTRalia - exPRess WaRRanTy and GuaRanTees

    additional guarantees, rights and remediesaustralian Purchasers - Guarantees under the australian Consumer law

    12Thebenefitsofthisexpresswarrantyareinadditiontootherguarantees,rights and remediesAustralian consumers have under theAustralianConsumerLaw.

    13ZodiacAustraliaproductscomewithguaranteesthatcannotbeexcludedundertheAustralianConsumerLaw.Youareentitledtoareplacementorrefundforamajorfailureandforcompensationforanyotherreasonablyforeseeablelossordamage.Youarealsoentitledtohavethegoodsrepairedorreplacedifthegoodsfailtobeofacceptablequalityandthefailuredoesnotamounttoamajorfailure.

    Purchasers in other Countries

    14ThelawsandregulationsofothercountriesmayconferonPurchasersinthosecountriesadditionalrightsandremedies.Totheextentthattheycannotbeexcludedormodified,Purchasershavethebenefitsofthoserightsandremediesinadditiontothebenefitsofthisexpresswarranty.Tothefullextentthatitispermissibletodoso,thoseadditionalrightsandremediesareexcludedormodifiedsoastobeconsistentwithZodiacAustralia’sexpresswarranty.

    inConsisTenCy WiTh WaRRanTy sTaTeMenTs in PRoduCT Manuals oR oTheR doCuMenTs aCCoMPanyinG PRoduCTs

    Ifanywarrantystatements inaZodiacAustraliaproductmanualorotherdocumentareinconsistentwiththeaboveExpressWarrantyandGuarantees,theaboveoverridesandreplacestheinconsistentstatements.

  • ZodiacisaregisteredtrademarkofZodiacGroupAustraliaPtyLtdABN87002641965

    ZodiaC CusToMeR seRviCe CenTRe

    ZodiacGroupAustralia:

    219WoodparkRd,Smithfield,NSW2164Australia

    Tel:1800688552Fax:1300781688

    Email:[email protected]

    Duetoconstantdevelopmentsandimprovements,specificationsmaychangewithoutnotice.

    Improperusecouldaffectperformanceandvoidwarranty.

    ©CopyrightZodiacAustraliaLtd2013

    W176781REV.A