Page 1: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

Triangle Flexible LSZH Shipboard/Offshore

Cables issue 9.1

www.tricab.com Superior Cable Solutions

Page 2: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

1 Kuwaiti patrol boats. Designed and built by Austal Ships Australia.

www.austal.com

2 Production platform in Gulf of Thailand

3 ‘Sovereign Lady’ built by Sovereign Yachts New Zealand Limited.

www.sovereignyachts.co.nz

4 ’Benchijigua Express’ - 416ft high speed vehicle-passenger trimaran ferry by

Austal Ships Pty Ltd, WA. www.austal.com

1

2

4

3

Page 3: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

Approvals

Page 4: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E

8 . 0 . 12

CONTENTS

S H I P B O A R D C A B L E S

PR

OD

UCT

SE

RIE

S

Flam

e R

etar

dant

IEC

6033

2-1

AS

/NZS

1660

.5.6

Flam

e R

etar

dant

IEC

6033

2-3A

AS

/NZS

1660

.5.1

Hal

ogen

Fre

e

IEC

6075

4-1&

2

AS

/NZS

1660

.5.3

Sm

oke

Em

issi

on

IEC

6103

4-1&

2

AS

/NZS

1660

.5.2

Fire

Res

ista

nt

IEC

6033

1 A

S/N

ZS16

60.5

.5PA

GE

NU

MB

ER

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 12

Introduction 4

Low Smoke Zero Halogen (LSZH) - what does it mean? 6

Features and Benefits 8

POWER AND CONTROL

Unarmoured BV ✓ ✓ ✓ ✓ ✕ 12

Unarmoured MK ✓ ✓ ✓ ✓ ✕ 14

Braided/Armoured DV ✓ ✓ ✓ ✓ ✕ 16

INSTRUMENTATION

Collective screened

Unarmoured RC ✓ ✓ ✓ ✓ ✕ 18

Braided/Armoured RS ✓ ✓ ✓ ✓ ✕ 20

Individual and collective screened

Unarmoured EW ✓ ✓ ✓ ✓ ✕ 22

Braided/Armoured EG ✓ ✓ ✓ ✓ ✕ 24

POWER AND CONTROL – F i re Resistant

Unarmoured RR ✓ ✓ ✓ ✓ ✓ 26

Braided/Armoured BH ✓ ✓ ✓ ✓ ✓ 28

INSTRUMENTATION – F i re Resistant

Collective screened

Unarmoured ES ✓ ✓ ✓ ✓ ✓ 30

Braided/Armoured FJ ✓ ✓ ✓ ✓ ✓ 32

Individual and collective screened

Unarmoured FC ✓ ✓ ✓ ✓ ✓ 34

Braided/Armoured FL ✓ ✓ ✓ ✓ ✓ 36

SHOREPOWER EZ ✓ ✓ ✓ ✓ ✕ 38

SWITCHBOARD/PANEL WIRE UP ✓ ✓ ✓ ✓ ✕ 40

Page 5: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T E C H N I C A L I N F O R M A T I O N

O F F S H O R E O I L A N D G A S C A B L E S

PR

OD

UCT

SE

RIE

S

Flam

e R

etar

dant

IEC

6033

2-1

AS

/NZS

1660

.5.6

Flam

e R

etar

dant

IEC

6033

2-3A

AS

/NZS

1660

.5.1

Hal

ogen

Fre

e

IEC

6075

4-1&

2

AS

/NZS

1660

.5.3

Sm

oke

Em

issi

on

IEC

6103

4-1&

2

AS

/NZS

1660

.5.2

Fire

Res

ista

nt

IEC

6033

1 A

S/N

ZS16

60.5

.5PA

GE

NU

MB

ER

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 3

POWER AND CONTROL

Braided/Armoured PJ ✓ ✓ ✓ ✓ ✕ 42

INSTRUMENTATION

Collective screened

Braided/Armoured RB ✓ ✓ ✓ ✓ ✕ 44

Individual and collective screened

Braided/Armoured FZ ✓ ✓ ✓ ✓ ✕ 46

POWER AND CONTROL – F i re Resistant

Braided/Armoured HT ✓ ✓ ✓ ✓ ✓ 48

INSTRUMENTATION – F i re Resistant

Collective screened

Braided/Armoured FK ✓ ✓ ✓ ✓ ✓ 50

Individual and collective screened

Braided/Armoured FE ✓ ✓ ✓ ✓ ✓ 52

SWITCHBOARD/PANEL WIRE UP ✓ ✓ ✓ ✓ ✕ 54

55

Page 6: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 14

INTRODUCTION

Welcome to Issue 9.1 of our Shipboard/Offshore catalogue.

Triangle has been manufacturing and supplying specialized cables to the marine industry for over 30 years.

Our aim has always been to design and manufacture the most innovative cables possible, and supply them in the

most customer focused manner possible.

As a privately owned, family enterprise, we retain old fashioned values in how we conduct business and how we

treat our customers, our suppliers and our dedicated Triangle team.

Over the years, we have expanded our manufacturing and sales facilities throughout the world. We now operate

three production plants and fifteen sales/distribution offices. (see back page for details).

We have also significantly expanded our product range and associated Certifications/Approvals. We now produce

cables that conform to AS/NZS1660, IEC60092-350, IEEE45, IEEE1580,TypeP, BS6883 and NEK606(MUD).

We have developed proprietary processes and raw materials, that enable us to produce highly flexible LSZH

cables with reduced Bending Radius. This saves installation time and reduces both space and cable usage.

We look forward to personally discussing your requirements, and providing cost-effective solutions that add value

to your business.

108ft Orca Class inshore patrol vessel by Victoria Shipyard, Victoria BC

Page 7: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1
Page 8: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

LSZHLSZH simply translates to Low Smoke Zero Halogen and refers to the behaviour ofchemical compounds when combusted - specifically the quantity of smoke generatedand the toxicity of the emissions.

Halogens - What are they?Halogens are a group of five elements comprising; Fluorine, Chlorine, Bromine, Iodineand Astatine.

Halogens - and the effect of combustionIn their basic form, Halogens are very toxic, strong oxidizers and very chemicallyreactive. In the event of combustion, LSZH and non LSZH cables behave in verydifferent ways, as indicated below.

Fluorine Chlorine Bromine Iodine Astatine

Triangle LSZH Cables

NO HALOGENS HALOGEN EMISSIONS

CORROSIVEACIDS

LOW SMOKE DENSE SMOKE

NO ACIDS

Non LSZH Cables

LOW SMOKE ZERO HALOGEN (LSZH)What does it mean?

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 16

Page 9: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

What is the difference between LSZH and non LSZHcables?

LSZH cables have a zero Halogen content, emit no toxic fumes,generate very little smoke and produce no corrosive or causticacids. LSZH cables are therefore ideally suited for all marineapplications where personnel safety and protection of valuableequipment are of paramount importance.

Non LSZH cables, or Halogenated Cables, are typicallymanufactured from thermoplastic compounds, such as PVC. Oncombustion, these compounds generate highly toxic fumes thatcause severe irritation to the eyes, nose, mouth, throat andlungs. Increased concentrations are considered fatal to humans.

They also generate large volumes of dense black smoke thatblocks visibility and severely disrupts evacuation procedures. Thesmoke and fumes can also lead to suffocation from smokeinhalation. A one metre length of burning cable that contains

Triangle LSFLEX® - Insulation & Jacket Materials✓ are halogen free

✓ emit low smoke

✓ do not form corrosive acids

✓ have an extremely low fuel element

LOW SMOKE ZERO HALOGEN (LSZH)What does it mean?

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 7

IEC 60332-1IEC 60332-3(A)IEC 60754-1&2IEC 61034-1&2

AS/NZS1660.5.1AS/NZS1660.5.2AS/NZS1660.5.3AS/NZS1660.5.6

Triangle LSFLEX® - Insulation & Jacket Materials comply to the following standards:

Page 10: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

Fine Copper Stranding - Triangle uses very fine 0.3mmcopper wire for all conductors, in accordance with IEC60228 Class 5&6 and AS/NZS 1125.

Round Concentric Cores - Triangle exclusively manufactures round cores throughout its entire size range,and does not use sectorial conductors.

Lightweight - Triangle has developed specific productranges that have reduced weight.

Small OD - Triangle has developed specific product rangesthat have reduced OD's.

Flexible Construction - Triangle uses a combination offine conductors, special compounds and manufacturingprocess to produce a very flexible cable.

Metre marking - All Triangle cables are metre-marked asstandard, with a descending number (feet marking alsoavailable).

Product marking - Triangle offers personalized text mes-sages printed onto the cable at regular intervals, even forshort lengths.

Make to order facility - Triangle can manufacture cablesexactly to customer specifications.

F E A T U R E S B E N E F I T S

Significantly increased flexibility has numerous practical benefits, including reduced installation time and easiercable handing. These benefits translate directly intoreduced installation time and cost.

Standard lugs, terminals and connectors can be used, saving installation time, inventory and cost - also providingbetter electrical contact with standard round lugs.

Especially relevant to high speed craft, sailing yachts etc.where weight saving translates into improved performanceand overall cost benefits. Makes handling much easierduring installation.

Additional cables can be installed within a specified cabletray, ladder or conduit. A smaller bending radius benefitstight configurations, and smaller glands reduce cost.

Reduced installation time and cost, improved bendingradius and safer cable handling (especially larger sizes).

Assists the installation process and enables accurate stockmanagement.

Project Reference Codes, Company Name, Part Numbers,Quality Data, Marketing Information etc. can all be clearlymarked.

No need for the user to compromise or accept an alterna-tive cable. Customers receive exactly what they need.

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 18

FEATURES AND BENEFITS

Page 11: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

Global distribution - Triangle operates its own network ofcompany offices and warehouses worldwide. We currently have operations in Australia, NZ, North America and Asia.

Research & development - Triangle maintains a veryactive R&D programme. Working very closely with our salesteam and customers, we are continually improving cableperformance.

Quick response - Triangle has invested in manpower,machinery and materials to provide a short leadtimemanufacturing capability.

Reliable long-term partner - Triangle has been supplyinginnovative cable solutions since 1978. We believe in longterm partnerships and have a solid track record of successfully completed projects worldwide.

Approvals - Triangle maintains approvals from numerouscertification bodies, including LR, DNV, ABS, BV, GL, UL,CSA. If required, we also obtain specific case approval.

Quality accreditation - Triangle operates an accreditedQuality system in accordance with ISO 9001:2008, bothwithin our manufacturing plant and our global offices and warehouses.

We support customer projects wherever they may be,streamlining logistics, increasing supply reliability and saving time and money.

New cable technologies are introduced to our customerson an ongoing basis.

When cable is needed urgently, either due to an emer-gency or unexpected contingency, Triangle has the systemsin place to fast-track the manufacturing process, reducingdowntime and saving time and money.

We believe that satisfied customers are our strength andwe do everything in our power to ensure that we both growand prosper over the long term.

Reliable certification simplifies the task for procurementand engineering, saving time and money. It also allowscables left over from one project to be used for future projects.

We continually improve our quality performance, which in turn provides improved products and services to ourcustomers.

F E A T U R E S B E N E F I T S

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 9I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 9

Page 12: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1
Page 13: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

SHIPBOARD CABLES

POWER AND CONTROL

Unarmoured BV 12

Unarmoured MK 14

Braided/Armoured DV 16

INSTRUMENTATION

Collective screened

Unarmoured RC 18

Braided/Armoured RS 20

Individual and collective screened

Unarmoured EW 22

Braided/Armoured EG 24

POWER AND CONTROL – F i re Resistant

Unarmoured RR 26

Braided/Armoured BH 28

INSTRUMENTATION – F i re Resistant

Collective screened

Unarmoured ES 30

Braided/Armoured FJ 32

Individual and collective screened

Unarmoured FC 34

Braided/Armoured FL 36

SHOREPOWER EZ 38

SWITCHBOARD/PANEL WIRE UP 40

Page 14: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 112

BV

CONSTRUCTIONConductor: Finely stranded annealed copper

to IEC 60228 Class 5&6 & AS/NZS 1125.

Available in plain or tinned.

Insulation: LSFLEX®R-30, Cross-linked,

Polyolefinic, Thermoset, Flame Retardant,

Low Smoke, Zero Halogen (HF-90 to

IEC 60092-351) Splash resistant to oil,

skydrol, petrol, acid, sea water.

Resists ozone and UV.

Ripcord: High strength ripcord under jacket

Jacket: LSFLEX®S-50, Polyolefinic,

Flame Retardant, Low Smoke, Zero Halogen

(SHF-1 to IEC 60092-359) Splash resistant to

oil, skydrol, petrol, acid, sea water.

Resists ozone and UV.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING600/1000 Volts

CORE COLOURSTo customer specification

JACKET COLOURTo customer specification

STANDARDS

APPROVALS

APPLICATIONFlexible Power and Control cables suitable for all shipboard and marine applications.

NUMBER OF MINIMUM CONDUCTOR NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING DIAMETER OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS (mm) INSULATION (mm) (kg/km) (Amps)

AREA (mm2) (mm) (mm) NOMINAL

1c 6 20 3.1 4.6 6.7 85 52

1c 10 23 4.1 5.6 7.7 129 72

1c 16 27 5.1 6.7 9.0 188 96

1c 25 32 6.4 8.4 10.7 282 127

1c 35 37 7.8 9.8 12.3 385 157

1c 50 42 9.2 11.5 14.0 540 196

1c 70 48 10.8 13.3 16.0 730 242

1c 95 55 12.8 15.3 18.3 981 293

1c 120 61 14.5 17.3 20.4 1216 339

1c 150 69 16.3 19.5 22.9 1541 389

1c 185 76 18.0 21.7 25.2 1869 444

1c 240 84 20.3 24.2 28.0 2389 522

1c 300 93 22.5 27.2 31.1 2998 601

1c 400 104 26.0 30.7 34.8 3858 690

1c 500 116 29.2 34.4 38.7 4855 720

1c 630 130 32.8 38.4 43.2 6098 780

*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

AS/NZS 1125AS/NZS 1660.5.1AS/NZS 1660.5.2AS/NZS 1660.5.3AS/NZS 1660.5.6

IEC 60228IEC 60092-350 IEC 60092-353IEC 60332-1 IEC 60332-3-22 IEC 60754-1&2 IEC 61034-1&2

IEEE 45IEEE 1580

FLEXIBLE SHIPBOARD POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

APPROX. NUMBEROF WIRES

TRIANGLE CLASS 5 CLASS 6

84 84 192

144 80 320

224 128 512

350 200 800

490 280 1120

707 400 705

991 356 990

1344 485 1340

1692 614 1690

2124 765 2123

2584 994 1470

3344 1125 1905

4144 1530 2385

5488 2035 3200

6944 1768 4010

8736 3200 5020

LR, DNV, ABS, GL, BV, USCG, TC Transport Canada Marine Safety“Cable constructions, Jackets, and Innercomponents tested to UL 1309 - CSA C22.2 No. 245 for Cold Bend (-40C) and Cold Impact (-35C)”

Page 15: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

NUMBER OF MINIMUM OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS (mm) (kg/km) (Amps)

AREA (mm2) (mm) NOMINAL2c 1.5 24 8.1 86 202c 2.5 28 9.5 124 262c 4 31 10.3 163 342c 6 35 11.8 223 442c 10 41 13.8 334 612c 16 49 16.2 481 822c 25 59 19.8 745 1082c 35 68 22.7 1008 1333c 1.5 25 8.4 106 163c 2.5 30 10.1 149 213c 4 33 10.9 200 283c 6 37 12.5 276 363c 10 45 14.9 430 503c 16 52 17.4 626 673c 25 63 21.0 959 893c 35 73 24.2 1303 1103c 50 83 27.7 1836 1373c 70 96 32.0 2491 1693c 95 110 36.7 3354 2053c 120 123 41.0 4161 2373c 150 139 46.2 5289 2723c 185 154 51.2 6439 3113c 240 171 57.0 8219 3654c 1.5 28 9.5 126 164c 2.5 33 11.0 180 214c 4 36 12.1 250 284c 6 41 13.6 341 364c 10 49 16.3 535 504c 16 57 19.1 784 674c 25 70 23.3 1215 894c 35 80 26.8 1654 1104c 50 93 31.0 2351 1374c 70 107 35.6 3173 1694c 95 122 40.8 4275 2054c 120 137 45.8 5323 2374c 150 154 51.5 6763 2724c 185 171 57.0 8226 3115c 1.5 31 10.4 162 165c 2.5 37 12.2 235 215c 4 40 13.3 317 285c 6 46 15.2 437 365c 10 55 18.2 680 505c 16 64 21.3 990 675c 25 78 26.1 1526 895c 35 90 30.0 2071 1105c 50 104 34.7 2936 1375c 70 120 40.0 3972 1695c 95 137 45.8 5339 2055c 120 154 51.4 6635 2375c 150 173 57.8 8416 2725c 185 192 64.1 10253 3115c 240 214 71.3 13083 3657c 1.5 34 11.3 179 12

10c 1.5 43 14.3 254 1112c 1.5 44 14.8 293 1014c 1.5 47 15.6 333 1016c 1.5 50 16.7 382 919c 1.5 52 17.5 441 924c 1.5 61 20.5 557 827c 1.5 63 21.1 615 833c 1.5 69 22.9 743 737c 1.5 71 23.8 821 77c 2.5 39 13.1 258 16

10c 2.5 50 16.8 376 1412c 2.5 52 17.5 436 1314c 2.5 55 18.4 497 1216c 2.5 59 19.7 569 1219c 2.5 62 20.8 659 1124c 2.5 73 24.3 833 1027c 2.5 76 25.2 933 1033c 2.5 82 27.2 1116 937c 2.5 85 28.4 1249 9

*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 110°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 13

BVFLEXIBLE SHIPBOARD POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

CONDUCTORDIAMETER

(mm)

1.52.12.53.14.15.16.47.81.52.12.53.14.15.16.47.89.2

10.812.814.516.318.020.31.52.12.53.14.15.16.47.89.2

10.812.814.516.318.01.52.12.53.14.15.16.47.89.2

10.812.814.516.318.020.31.51.51.51.51.51.51.51.51.51.52.12.12.12.12.12.12.12.12.12.1

APPROX. NUMBEROF WIRES

TRIANGLE CLASS 5 CLASS 6- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120

- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990

1344 485 13401692 614 16902124 765 21232584 994 14703344 1125 1905

- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990

1344 485 13401692 614 16902124 765 21232584 994 1470

- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990

1344 485 13401692 614 16902124 765 21232584 994 14703344 1125 1905

- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -

Page 16: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 114

MK FLEXIBLE SHIPBOARD POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

CONSTRUCTIONConductor: Finely stranded annealed copper

to IEC 60228 Class 5&6 & AS/NZS 1125.

Available in plain or tinned.

Insulation: LSFLEX®R-30, Cross-linked,

Polyolefinic, Thermoset, Flame Retardant,

Low Smoke, Zero Halogen (HF-90 to

IEC 60092-351) Splash resistant to oil,

skydrol, petrol, acid, sea water.

Resists ozone and UV.

Ripcord: High strength ripcord under jacket

Jacket: LSFLEX®S-50, Polyolefinic,

Flame Retardant, Low Smoke, Zero Halogen

(SHF-1 to IEC 60092-359) Splash resistant to

oil, skydrol, petrol, acid, sea water.

Resists ozone and UV. Excellent abrasion

resistance.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING600/1000 Volts

CORE COLOURSTo customer specification

JACKET COLOURTo customer specification

STANDARDS

APPROVALS

APPLICATIONFlexible Power and Control cables suitable for all shipboard and marine applications.

AS/NZS 1125

AS/NZS 1660.5.1

AS/NZS 1660.5.2

AS/NZS 1660.5.3

AS/NZS 1660.5.6

IEC 60228

IEC 60092-350

IEC 60092-353

IEC 60332-1

IEC 60332-3-22

IEC 60754-1&2

IEC 61034-1&2

IEEE 45

IEEE 1580

NUMBER OF MINIMUM CONDUCTOR NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING DIAMETER OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS (mm) INSULATION (mm) (kg/km) (Amps)

AREA (mm2) (mm) (mm) NOMINAL

1c 6 20 3.1 4.6 6.7 85 52

1c 10 23 4.1 5.6 7.7 129 72

1c 16 27 5.1 6.7 9.0 188 96

1c 25 32 6.4 8.4 10.7 282 127

1c 35 37 7.8 9.8 12.3 385 157

1c 50 42 9.2 11.5 14.0 540 196

1c 70 48 10.8 13.3 16.0 730 242

1c 95 55 12.8 15.3 18.3 981 293

1c 120 61 14.5 17.3 20.4 1216 339

1c 150 69 16.3 19.5 22.9 1541 389

1c 185 76 18.0 21.7 25.2 1869 444

1c 240 84 20.3 24.2 28.0 2389 522

1c 300 93 22.5 27.2 31.1 2998 601

1c 400 104 26.0 30.7 34.8 3858 690

1c 500 116 29.2 34.4 38.7 4855 720

1c 630 130 32.8 38.4 43.2 6098 780

*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

APPROX. NUMBEROF WIRES

TRIANGLE CLASS 5 CLASS 6

84 84 192

144 80 320

224 128 512

350 200 800

490 280 1120

707 400 705

991 356 990

1344 485 1340

1692 614 1690

2124 765 2123

2584 994 1470

3344 1125 1905

4144 1530 2385

5488 2035 3200

6944 1768 4010

8736 3200 5020

LR, DNV, ABS, GL, BV, USCG, RAN

Transport Canada Marine Safety

“Cable constructions, Jackets, and Inner

components tested to UL 1309 - CSA C22.2 No. 245

for Cold Bend (-40C) and Cold Impact (-35C)”

DEF(AUST) 5000

Page 17: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 15

MKFLEXIBLE SHIPBOARD POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF MINIMUM OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS (mm) (kg/km) (Amps)

AREA (mm2) (mm) NOMINAL2c 1.5 24 8.1 86 202c 2.5 28 9.5 124 262c 4 31 10.3 163 342c 6 35 11.8 223 442c 10 41 13.8 334 612c 16 49 16.2 481 822c 25 59 19.8 745 1082c 35 68 22.7 1008 1333c 1.5 25 8.4 106 163c 2.5 30 10.1 149 213c 4 33 10.9 200 283c 6 37 12.5 276 363c 10 45 14.9 430 503c 16 52 17.4 626 673c 25 63 21.0 959 893c 35 73 24.2 1303 1103c 50 83 27.7 1836 1373c 70 96 32.0 2491 1693c 95 110 36.7 3354 2053c 120 123 41.0 4161 2373c 150 139 46.2 5289 2723c 185 154 51.2 6439 3113c 240 171 57.0 8219 3654c 1.5 28 9.5 126 164c 2.5 33 11.0 180 214c 4 36 12.1 250 284c 6 41 13.6 341 364c 10 49 16.3 535 504c 16 57 19.1 784 674c 25 70 23.3 1215 894c 35 80 26.8 1654 1104c 50 93 31.0 2351 1374c 70 107 35.6 3173 1694c 95 122 40.8 4275 2054c 120 137 45.8 5323 2374c 150 154 51.5 6763 2724c 185 171 57.0 8226 3115c 1.5 31 10.4 162 165c 2.5 37 12.2 235 215c 4 40 13.3 317 285c 6 46 15.2 437 365c 10 55 18.2 680 505c 16 64 21.3 990 675c 25 78 26.1 1526 895c 35 90 30.0 2071 1105c 50 104 34.7 2936 1375c 70 120 40.0 3972 1695c 95 137 45.8 5339 2055c 120 154 51.4 6635 2375c 150 173 57.8 8416 2725c 185 192 64.1 10253 3115c 240 214 71.3 13083 3657c 1.5 34 11.3 179 12

10c 1.5 43 14.3 254 1112c 1.5 44 14.8 293 1014c 1.5 47 15.6 333 1016c 1.5 50 16.7 382 919c 1.5 52 17.5 441 924c 1.5 61 20.5 557 827c 1.5 63 21.1 615 833c 1.5 69 22.9 743 737c 1.5 71 23.8 821 77c 2.5 39 13.1 258 16

10c 2.5 50 16.8 376 1412c 2.5 52 17.5 436 1314c 2.5 55 18.4 497 1216c 2.5 59 19.7 569 1219c 2.5 62 20.8 659 1124c 2.5 73 24.3 833 1027c 2.5 76 25.2 933 1033c 2.5 82 27.2 1116 937c 2.5 85 28.4 1249 9

*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 110°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

CONDUCTORDIAMETER

(mm)

1.52.12.53.14.15.16.47.81.52.12.53.14.15.16.47.89.2

10.812.814.516.318.020.31.52.12.53.14.15.16.47.89.2

10.812.814.516.318.01.52.12.53.14.15.16.47.89.2

10.812.814.516.318.020.31.51.51.51.51.51.51.51.51.51.52.12.12.12.12.12.12.12.12.12.1

APPROX. NUMBEROF WIRES

TRIANGLE CLASS 5 CLASS 6- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120

- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990

1344 485 13401692 614 16902124 765 21232584 994 14703344 1125 1905

- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990

1344 485 13401692 614 16902124 765 21232584 994 1470

- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990

1344 485 13401692 614 16902124 765 21232584 994 14703344 1125 1905

- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -

Page 18: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 116

DV

CONSTRUCTIONConductor: Finely stranded annealed copperto IEC 60228 Class 5&6 & AS/NZS 1125.Available in plain or tinned.

Insulation: LSFLEX®R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant, Low Smoke, Zero Halogen (HF-90 to IEC 60092-351) Splash resistant to oil, skydrol, petrol, acid, sea water. Resists ozone and UV.

Separator: Polypropylene Tape

Braid/Armour Options:Tinned Copper Wire Braid (90%)Galvanized Steel Wire Braid (90%)(Also available with drain wire under the braid)

Ripcord: High strength ripcord under jacket

Jacket: LSFLEX®S-50, Polyolefinic, Flame Retardant, Low Smoke, Zero Halogen (SHF-1 to IEC 60092-359) Splash resistant tooil, skydrol, petrol, acid, sea water. Resists ozone and UV.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING600/1000 Volts

CORE COLOURSTo customer specification

JACKET COLOURTo customer specification

STANDARDS

APPROVALS

APPLICATIONFlexible Power and Control cables suitable for all shipboard and marine applications where

mechanical or EMC protection is required.

AS/NZS 1125

AS/NZS 1660.5.1

AS/NZS 1660.5.2

AS/NZS 1660.5.3

AS/NZS 1660.5.6

IEC 60228

IEC 60092-350

IEC 60092-353

IEC 60331

IEC 60332-1

IEC 60332-3-22

IEC 60754-1&2

IEC 61034-1&2

IEEE 45

IEEE 1580

FLEXIBLE SHIPBOARD BRAIDED/ARMOURED POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF MINIMUM NOMINAL NOMINAL NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING OD OVER OD OVER OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS INSULATION BEDDING BRAID (mm) (kg/km) (Amps)

AREA (mm2) (mm) (mm) (mm) (mm) NOMINAL

1c 6 33 4.6 5.4 6.3 8.3 128 52

1c 10 38 5.6 6.5 7.3 9.6 190 72

1c 16 42 6.8 7.6 8.3 10.6 247 96

1c 25 50 8.4 9.2 10.0 12.5 356 127

1c 35 56 9.8 10.7 11.5 14.0 463 157

1c 50 63 11.5 12.3 13.1 15.8 635 196

1c 70 71 13.3 14.1 14.9 17.9 838 242

1c 95 80 15.3 16.2 17.0 20.1 1104 293

1c 120 88 17.3 18.1 18.9 22.0 1343 339

1c 150 98 19.5 20.4 21.2 24.5 1683 389

1c 185 107 21.7 22.5 23.3 26.9 2026 444

1c 240 118 24.2 25.1 25.9 29.6 2602 522

1c 300 129 27.2 28.0 28.3 32.3 3225 601

1c 400 147 30.7 31.5 32.3 36.7 4098 690

1c 500 162 34.4 35.2 36.0 40.5 5113 720

1c 630 180 38.4 39.3 40.1 45.0 6386 780

*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

APPROX. NUMBEROF WIRES

TRIANGLE CLASS 5 CLASS 6

84 84 192

144 80 320

224 128 512

350 200 800

490 280 1120

707 400 705

991 356 990

1344 485 1340

1692 614 1690

2124 765 2123

2584 994 1470

3344 1125 1905

4144 1530 2385

5488 2035 3200

6944 1768 4010

8736 3200 5020

CONDUCTORDIAMETER

(mm)

3.1

4.1

5.1

6.4

7.8

9.2

10.8

12.8

14.5

16.3

18.0

20.3

22.5

26.0

29.2

32.8

LR, DNV, ABS, GL, BV, USCG, TC Transport Canada Marine Safety“Cable constructions, Jackets, and Innercomponents tested to UL 1309 - CSA C22.2 No. 245 for Cold Bend (-40C) and Cold Impact (-35C)”

Page 19: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 17

DVFLEXIBLE SHIPBOARD BRAIDED/ARMOURED POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF MINIMUM NOMINAL NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING OD OVER OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS BEDDING BRAID (mm) (kg/km) (Amps)

AREA (mm2) (mm) (mm) (mm) NOMINAL

2c 1.5 40 6.8 7.6 9.9 156 202c 2.5 45 8.0 8.8 11.1 193 262c 4 49 8.9 9.7 12.2 243 342c 6 54 10.2 10.9 13.4 306 442c 10 63 12.2 12.9 15.6 438 612c 16 71 14.5 14.9 17.8 599 822c 25 86 17.7 18.3 21.4 876 1082c 35 97 20.4 21.0 24.3 1154 1333c 1.5 41 7.3 8.1 10.4 168 163c 2.5 48 8.6 9.4 11.9 220 213c 4 51 9.5 10.3 12.8 276 283c 6 57 10.9 11.6 14.3 362 363c 10 66 13.1 13.8 16.5 521 503c 16 75 15.5 15.9 18.8 728 673c 25 91 18.9 19.5 22.9 1088 893c 35 104 21.9 22.5 26.0 1445 1103c 50 118 25.0 25.8 29.6 1990 1373c 70 135 28.9 29.7 33.9 2678 1693c 95 154 33.2 34.0 38.4 3514 2053c 120 172 37.3 38.1 42.9 4344 2373c 150 192 42.0 42.9 48.0 5476 2723c 185 212 46.6 47.4 53.0 6625 3113c 240 235 52.0 52.8 58.8 8398 3654c 1.5 44 8.0 8.8 11.1 187 164c 2.5 51 9.5 10.3 12.8 255 214c 4 55 10.5 11.3 13.8 326 284c 6 62 12.0 12.7 15.4 431 364c 10 72 14.5 15.2 18.1 640 504c 16 83 17.2 17.6 20.7 902 674c 25 100 21.1 21.6 25.0 1343 894c 35 115 24.4 24.9 28.7 1807 1104c 50 131 27.9 28.7 32.7 2529 1374c 70 150 32.2 33.0 37.4 3357 1694c 95 171 37.0 37.9 42.6 4469 2054c 120 190 41.6 42.4 47.6 5525 2374c 150 213 46.9 47.7 53.3 6971 2724c 185 235 52.0 52.8 58.8 8435 3115c 1.5 49 8.9 9.7 12.2 222 165c 2.5 56 10.6 11.4 13.9 298 215c 4 61 11.7 12.5 15.2 392 285c 6 68 13.4 14.1 17.0 521 365c 10 80 16.2 16.9 20.0 777 505c 16 92 19.3 19.6 22.9 1100 675c 25 111 23.6 24.2 27.7 1644 895c 35 127 27.4 27.9 31.8 2244 1105c 50 146 31.3 32.1 36.5 3105 1377c 1.5 52 9.8 10.6 13.1 239 12

10c 1.5 65 12.7 13.5 16.2 329 1112c 1.5 68 13.3 14.1 17.0 379 1014c 1.5 71 14.0 14.8 17.7 423 1016c 1.5 75 14.9 15.7 18.6 469 919c 1.5 79 15.8 16.6 19.7 541 924c 1.5 91 18.6 19.5 22.8 674 927c 1.5 94 19.2 20.1 23.4 735 933c 1.5 101 20.9 21.7 25.2 874 937c 1.5 105 21.8 22.6 26.1 957 97c 2.5 61 11.6 12.5 15.2 334 21

10c 2.5 75 15.1 15.9 18.8 464 2012c 2.5 79 15.8 16.6 19.7 536 1814c 2.5 83 16.7 17.5 20.6 603 1816c 2.5 87 17.8 18.6 21.7 671 1619c 2.5 92 18.9 19.7 23.0 778 1524c 2.5 107 22.3 23.1 26.6 971 1527c 2.5 109 23.0 23.8 27.4 1064 1533c 2.5 118 25.0 25.8 29.6 1270 1537c 2.5 123 26.1 26.9 30.8 1409 15

*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

CONDUCTORDIAMETER

(mm)

1.52.12.53.14.15.16.47.81.52.12.53.14.15.16.47.89.2

10.812.814.516.318.020.31.52.12.53.14.15.16.47.89.2

10.812.814.516.318.01.52.12.53.14.15.16.47.89.21.51.51.51.51.51.51.51.51.51.52.12.12.12.12.12.12.12.12.12.1

APPROX. NUMBEROF WIRES

TRIANGLE CLASS 5 CLASS 6

- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120

- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990

1344 485 13401692 614 16902124 765 21232584 994 14703344 1125 1905

- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990

1344 485 13401692 614 16902124 765 21232584 994 1470

- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705

- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -

Page 20: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 118

RC

CONSTRUCTIONConductor: Finely stranded tinned annealed

copper to IEC 60228 Class 5&6 & AS/NZS 1125.

Insulation: LSFLEX®R-30, Cross-linked,

Polyolefinic, Thermoset, Flame Retardant

Low Smoke, Zero Halogen (HF-90 to

IEC 60092-351) Splash resistant to oil,

skydrol, petrol, acid, sea water.

Resists ozone and UV.

Screen: Aluminium/Laminate Tape

Drain Wire: Tinned annealed copper

Separator: Polypropylene Tape

Ripcord: High strength ripcord under jacket

Jacket: LSFLEX®S-50, Polyolefinic,

Flame Retardant, Low Smoke, Zero Halogen

(SHF-1 to IEC 60092-359) Splash resistant to

oil, skydrol, petrol, acid, sea water.

Resists ozone and UV.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING250 Volts

CORE COLOURSTo customer specification

JACKET COLOURTo customer specification

STANDARDS

APPROVALS

APPLICATIONFlexible Instrumentation cables suitable for all shipboard and marine applications.

AS/NZS 1125

AS/NZS 1660.5.1

AS/NZS 1660.5.2

AS/NZS 1660.5.3

AS/NZS 1660.5.6

IEC 60228

IEC 60092-350

IEC 60092-376

IEC 60332-1

IEC 60332-3-22

IEC 60754-1&2

IEC 61034-1&2

IEEE 45

IEEE 1580

FLEXIBLE SHIPBOARD INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR OVERALL APPROX.PAIRS (p) DIAMETER DIAMETER WEIGHT

X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL

1p 0.5 0.95 7.9 71

2p 0.5 (quad formation) 0.95 8.9 88

4p 0.5 0.95 13.2 135

8p 0.5 0.95 16.6 222

10p 0.5 0.95 18.1 268

12p 0.5 0.95 19.8 318

16p 0.5 0.95 21.6 392

20p 0.5 0.95 22.8 470

24p 0.5 0.95 24.0 540

27p 0.5 0.95 24.9 593

36p 0.5 0.95 28.8 782

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

MINIMUMBENDINGRADIUS

(mm)

24

27

40

50

54

59

65

68

72

75

86

LR, DNV, ABS, GL, BV, USCG, TC Transport Canada Marine Safety“Cable constructions, Jackets, and Innercomponents tested to UL 1309 - CSA C22.2 No. 245 for Cold Bend (-40C) and Cold Impact (-35C)”

Page 21: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 19

RCFLEXIBLE SHIPBOARD INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR OVERALL APPROX.PAIRS (p) DIAMETER DIAMETER WEIGHT

X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL

1p 0.75 1.2 8.4 82 2p 0.75 (quad formation) 1.2 9.5 105 4p 0.75 1.2 14.2 169 6p 0.75 1.2 16.0 223 8p 0.75 1.2 18.3 287

10p 0.75 1.2 19.9 348 12p 0.75 1.2 21.5 402 14p 0.75 1.2 22.7 462 16p 0.75 1.2 23.8 512 20p 0.75 1.2 24.9 606 24p 0.75 1.2 26.4 712 27p 0.75 1.2 27.4 784 36p 0.75 1.2 31.7 1036 1p 1.0 1.3 8.8 95 2p 1.0 (quad formation) 1.3 9.8 118 4p 1.0 1.3 14.9 193 8p 1.0 1.3 18.9 326

10p 1.0 1.3 20.5 396 12p 1.0 1.3 22.2 459 16p 1.0 1.3 24.6 587 20p 1.0 1.3 25.9 709 24p 1.0 1.3 27.3 822 27p 1.0 1.3 28.6 919 36p 1.0 1.3 32.8 1198 1p 1.5 1.5 8.9 107 2p 1.5 (quad formation) 1.5 10.6 147 4p 1.5 1.5 16.3 243 8p 1.5 1.5 20.8 431

10p 1.5 1.5 22.7 525 12p 1.5 1.5 24.6 611 16p 1.5 1.5 27.1 785 20p 1.5 1.5 28.6 951 24p 1.5 1.5 30.1 1108 27p 1.5 1.5 31.5 1240 36p 1.5 1.5 36.4 1637 1p 2.5 2.1 9.5 137 2p 2.5 (quad formation) 2.1 12.3 2104p 2.5 2.1 19.1 350 8p 2.5 2.1 24.8 632

10p 2.5 2.1 26.7 769 12p 2.5 2.1 29.2 913 16p 2.5 2.1 32.2 1176 20p 2.5 2.1 34.0 1430 24p 2.5 2.1 35.8 1671 27p 2.5 2.1 37.5 1870 36p 2.5 2.1 43.3 2470

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

NUMBER OF CONDUCTOR OVERALL APPROX.TRIADS (t) DIAMETER DIAMETER WEIGHT

X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL

1t 0.75 1.2 9.0 94 3t 0.75 1.2 13.4 170 4t 0.75 1.2 14.8 216 7t 0.75 1.2 17.9 338 1t 1.5 1.5 9.9 128 3t 1.5 1.5 15.2 255 4t 1.5 1.5 16.6 317 7t 1.5 1.5 20.4 518

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

MINIMUMBENDINGRADIUS

(mm)

25284348556064687175798295262945576167747882869827324962687481869094

10928375774808897

102107112130

MINIMUMBENDINGRADIUS

(mm)

2740445430465061

Page 22: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 120

RS

CONSTRUCTIONConductor: Finely stranded tinned annealed

copper to IEC 60228 Class 5&6 & AS/NZS 1125.

Insulation: LSFLEX®R-30, Cross-linked,

Polyolefinic, Thermoset, Flame Retardant

Low Smoke, Zero Halogen (HF-90 to

IEC 60092-351) Splash resistant to oil,

skydrol, petrol, acid, sea water.

Resists ozone and UV.

Screen: Aluminium/Laminate Tape

Drain Wire: Tinned annealed copper

Separator: Polypropylene Tape

Braid/Armour Options:

Tinned Copper Wire Braid (90%)

Galvanized Steel Wire Braid (90%)

Ripcord: High strength ripcord under jacket

Jacket: LSFLEX®S-50, Polyolefinic,

Flame Retardant, Low Smoke, Zero Halogen

(SHF-1 to IEC 60092-359) Splash resistant to

oil, skydrol, petrol, acid, sea water.

Resists ozone and UV.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING250 Volts

CORE COLOURSTo customer specification

JACKET COLOURTo customer specification

STANDARDS

APPROVALS

APPLICATIONFlexible Instrumentation cables suitable for all shipboard and marine applications, where

mechanical or EMC protection is required.

AS/NZS 1125

AS/NZS 1660.5.1

AS/NZS 1660.5.2

AS/NZS 1660.5.3

AS/NZS 1660.5.6

IEC 60228

IEC 60092-350

IEC 60092-376

IEC 60332-1

IEC 60332-3-22

IEC 60754-1&2

IEC 61034-1&2

FLEXIBLE SHIPBOARD COLLECTIVESCREENED BRAIDED/ARMOUREDINSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1p 0.5 0.95 5.7 6.6 9.1 129

2p 0.5 (quad form) 0.95 6.5 7.4 9.9 141

4p 0.5 0.95 10.5 11.5 14.2 201

8p 0.5 0.95 13.6 14.7 17.6 307

10p 0.5 0.95 14.9 16.0 18.9 353

12p 0.5 0.95 16.3 17.5 20.6 410

16p 0.5 0.95 18.1 19.3 22.6 504

20p 0.5 0.95 19.1 20.3 23.6 577

24p 0.5 0.95 20.5 21.7 25.3 668

27p 0.5 0.95 21.6 22.9 26.4 729

36p 0.5 0.95 24.6 25.9 29.7 958

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

IEEE 45

IEEE 1580

MINIMUMBENDINGRADIUS

(mm)

36

40

57

71

76

82

91

95

101

106

119

LR, DNV, ABS, GL, BV, USCG,

Transport Canada Marine Safety

“Cable constructions, Jackets, and Inner

components tested to UL 1309 - CSA C22.2 No. 245

for Cold Bend (-40C) and Cold Impact (-35C)”

Page 23: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 21

RSFLEXIBLE SHIPBOARD COLLECTIVESCREENED BRAIDED/ARMOUREDINSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1t 0.75 1.2 6.2 7.4 10.0 146 3t 0.75 1.2 9.9 11.2 14.4 237 4t 0.75 1.2 11.0 12.3 15.6 281 7t 0.75 1.2 13.6 14.9 18.7 419 1t 1.5 1.5 7.6 8.8 10.9 178 3t 1.5 1.5 12.5 13.8 16.1 321 4t 1.5 1.5 13.9 15.1 17.6 398 7t 1.5 1.5 17.2 18.5 21.2 608

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1p 0.75 1.2 5.8 7.1 9.6 141 2p 0.75 (quad form) 1.2 6.7 8.0 10.5 159 4p 0.75 1.2 10.5 12.3 15.0 234 8p 0.75 1.2 14.0 16.2 19.1 372

10p 0.75 1.2 15.3 17.6 20.7 441 12p 0.75 1.2 16.8 19.2 22.6 51314p 0.75 1.2 17.6 20.2 23.5 56916p 0.75 1.2 18.6 21.3 24.6 62520p 0.75 1.2 19.6 22.4 25.9 736 24p 0.75 1.2 21.0 23.9 27.5 842 27p 0.75 1.2 22.2 25.2 29.0 980 36p 0.75 1.2 25.2 28.6 32.5 1217 1p 1.0 1.3 6.0 7.3 9.8 151 2p 1.0 (quad form) 1.3 6.9 8.3 10.6 168 4p 1.0 1.3 11.2 13.0 15.7 261 8p 1.0 1.3 14.6 16.8 19.9 423

10p 1.0 1.3 15.9 18.2 21.4 493 12p 1.0 1.3 17.5 19.9 23.3 575 16p 1.0 1.3 19.4 22.1 25.6 715 20p 1.0 1.3 20.4 23.2 26.7 833 24p 1.0 1.3 21.9 24.8 28.6 1012 27p 1.0 1.3 23.1 26.2 29.9 1100 36p 1.0 1.3 26.3 29.7 33.8 1391 1p 1.5 1.5 7.1 7.9 10.4 170 2p 1.5 (quad form) 1.5 8.2 9.0 11.5 203 4p 1.5 1.5 13.5 14.3 17.2 325 8p 1.5 1.5 17.7 18.5 21.6 529

10p 1.5 1.5 19.3 20.2 23.5 631 12p 1.5 1.5 21.2 22.0 25.6 739 16p 1.5 1.5 23.6 24.4 28.2 927 20p 1.5 1.5 24.9 25.7 29.4 1089 24p 1.5 1.5 26.7 27.5 31.4 1301 27p 1.5 1.5 28.2 29.0 32.9 1423 36p 1.5 1.5 32.1 32.9 37.3 1817 1p 2.5 2.1 8.3 9.2 11.7 213 2p 2.5 (quad form) 2.1 9.7 10.5 13.0 269 4p 2.5 2.1 16.1 16.9 20.0 447 8p 2.5 2.1 21.2 22.0 25.5 757

10p 2.5 2.1 23.2 24.0 27.5 896 12p 2.5 2.1 25.4 26.3 30.0 1052 16p 2.5 2.1 28.3 29.1 33.1 1331 20p 2.5 2.1 29.8 30.7 34.8 1608 24p 2.5 2.1 32.0 32.8 37.2 1873 27p 2.5 2.1 33.8 34.6 39.2 2081 36p 2.5 2.1 38.5 39.3 44.1 2682

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

MINIMUMBENDINGRADIUS

(mm)

3842607683909498

104110116130394263808593

1021071141201354246698794

102113118126132149475280

102110120132139149157176

MINIMUMBENDINGRADIUS

(mm)

4058627544647185

Page 24: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 122

EW

CONSTRUCTIONConductor: Finely stranded tinned annealed

copper to IEC 60228 Class 5&6 & AS/NZS 1125.

Insulation: LSFLEX®R-30, Cross-linked,

Polyolefinic, Thermoset, Flame Retardant

Low Smoke, Zero Halogen (HF-90 to

IEC 60092-351) Splash resistant to oil,

skydrol, petrol, acid, sea water.

Resists ozone and UV.

Screen: Individual and Collective

Aluminium/Laminate Tape

Drain Wire: Tinned annealed copper

Separator: Polypropylene Tape

Ripcord: High strength ripcord under jacket

Jacket: LSFLEX®S-50, Polyolefinic,

Flame Retardant, Low Smoke, Zero Halogen

(SHF-1 to IEC 60092-359) Splash resistant to

oil, skydrol, petrol, acid, sea water.

Resists ozone and UV.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING250 Volts

CORE COLOURSTo customer specification

JACKET COLOURTo customer specification

STANDARDS

APPROVALS

APPLICATIONFlexible Instrumentation cables suitable for all shipboard and marine applications.

AS/NZS 1125

AS/NZS 1660.5.1

AS/NZS 1660.5.2

AS/NZS 1660.5.3

AS/NZS 1660.5.6

IEC 60228

IEC 60092-350

IEC 60092-376

IEC 60332-1

IEC 60332-3-22

IEC 60754-1&2

IEC 61034-1&2

IEEE 45

IEEE 1580

FLEXIBLE SHIPBOARD INDIVIDUAL & COLLECTIVE SCREENED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR OVERALL APPROX.PAIRS (p) DIAMETER DIAMETER WEIGHT

X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL

1p 0.5 0.95 7.9 69

2p 0.5 0.95 12.4 132

4p 0.5 0.95 14.7 180

8p 0.5 0.95 18.6 303

10p 0.5 0.95 20.3 367

12p 0.5 0.95 21.9 425

16p 0.5 0.95 24.2 543

20p 0.5 0.95 25.5 654

24p 0.5 0.95 27.1 759

27p 0.5 0.95 28.6 852

36p 0.5 0.95 32.3 1102

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

MINIMUMBENDINGRADIUS

(mm)

24

37

44

56

61

66

73

76

81

86

119

LR, DNV, ABS, GL, BV, USCG, TC

Transport Canada Marine Safety

“Cable constructions, Jackets, and Inner

components tested to UL 1309 - CSA C22.2 No. 245

for Cold Bend (-40C) and Cold Impact (-35C)”

Page 25: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 23

EWFLEXIBLE SHIPBOARD INDIVIDUAL & COLLECTIVE SCREENED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR OVERALL APPROX.PAIRS (p) DIAMETER DIAMETER WEIGHT

X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL

1p 0.75 1.2 8.4 80 2p 0.75 1.2 13.2 153 4p 0.75 1.2 15.8 212 8p 0.75 1.2 20.2 372

10p 0.75 1.2 21.8 442 12p 0.75 1.2 23.8 524 16p 0.75 1.2 26.4 671 20p 0.75 1.2 27.6 798 24p 0.75 1.2 29.5 943 27p 0.75 1.2 31.2 1057 36p 0.75 1.2 35.1 1371 1p 1.0 1.3 8.8 93 2p 1.0 1.3 13.6 172 4p 1.0 1.3 16.2 244 8p 1.0 1.3 20.8 433

10p 1.0 1.3 22.7 528 12p 1.0 1.3 24.5 614 16p 1.0 1.3 27.2 789 20p 1.0 1.3 28.6 957 24p 1.0 1.3 30.4 1117 27p 1.0 1.3 32.1 1252 36p 1.0 1.3 36.4 1646 1p 1.5 1.5 9.4 111 2p 1.5 1.5 14.8 211 4p 1.5 1.5 17.4 301 5p 1.5 1.5 18.7 356 8p 1.5 1.5 22.8 543

10p 1.5 1.5 24.6 651 12p 1.5 1.5 26.9 773 16p 1.5 1.5 29.7 995 20p 1.5 1.5 31.3 1209 24p 1.5 1.5 33.5 1430 27p 1.5 1.5 35.2 1587 36p 1.5 1.5 39.9 2087 1p 2.5 2.1 10.6 148 2p 2.5 2.1 17.1 288 4p 2.5 2.1 20.5 423 8p 2.5 2.1 26.5 765

10p 2.5 2.1 28.9 936 12p 2.5 2.1 31.5 1110 16p 2.5 2.1 34.8 1434 20p 2.5 2.1 36.7 1745 24p 2.5 2.1 39.2 2066 27p 2.5 2.1 41.2 2297 36p 2.5 2.1 46.7 3022

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

NUMBER OF CONDUCTOR OVERALL APPROX.TRIADS (t) DIAMETER DIAMETER WEIGHT

X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL1t 0.75 1.2 8.3 90 3t 0.75 1.2 13.6 208 4t 0.75 1.2 15.0 257 7t 0.75 1.2 18.1 406 1t 1.5 1.5 9.9 127 3t 1.5 1.5 16.4 308 4t 1.5 1.5 18.1 3947t 1.5 1.5 21.9 633

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

MINIMUMBENDINGRADIUS

(mm)

25404761657179838894

10526414962687382869296

109284452566874818994

101106120325161798794

104110118124140

MINIMUMBENDINGRADIUS

(mm)2541455430495466

Page 26: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 124

EG

CONSTRUCTIONConductor: Finely stranded tinned annealed

copper to IEC 60228 Class 5&6 & AS/NZS 1125.

Insulation: LSFLEX®R-30, Cross-linked,

Polyolefinic, Thermoset, Flame Retardant

Low Smoke, Zero Halogen (HF-90 to

IEC 60092-351) Splash resistant to oil,

skydrol, petrol, acid, sea water.

Resists ozone and UV.

Screen: Individual and Collective

Aluminium/Laminate Tape

Drain Wire: Tinned annealed copper

Separator: Polypropylene Tape

Braid/Armour Options:

Tinned Copper Wire Braid (90%)

Galvanized Steel Wire Braid (90%)

Ripcord: High strength ripcord under jacket

Jacket: LSFLEX®S-50, Polyolefinic,

Flame Retardant, Low Smoke, Zero Halogen

(SHF-1 to IEC 60092-359) Splash resistant to

oil, skydrol, petrol, acid, sea water.

Resists ozone and UV.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING250 Volts

CORE COLOURSTo customer specification

JACKET COLOURTo customer specification

STANDARDS

APPROVALS\

APPLICATIONFlexible Instrumentation cables suitable for all shipboard and marine applications, where

mechanical or EMC protection is required.

AS/NZS 1125

AS/NZS 1660.5.1

AS/NZS 1660.5.2

AS/NZS 1660.5.3

AS/NZS 1660.5.6

IEC 60228

IEC 60092-350

IEC 60092-376

IEC 60332-1

IEC 60332-3-22

IEC 60754-1&2

IEC 61034-1&2

FLEXIBLE SHIPBOARD INDIVIDUAL & COLLECTIVE SCREENED BRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1p 0.5 0.95 6.0 6.9 9.2 129

2p 0.5 0.95 10.0 11.0 13.5 239

4p 0.5 0.95 12.1 13.1 15.8 249

8p 0.5 0.95 15.6 16.8 19.9 398

10p 0.5 0.95 17.1 18.3 21.4 462

12p 0.5 0.95 18.7 19.9 23.2 538

16p 0.5 0.95 20.8 22.0 25.5 667

20p 0.5 0.95 21.9 23.1 26.6 772

24p 0.5 0.95 23.4 24.7 28.4 896

27p 0.5 0.95 24.7 26.0 29.7 982

36p 0.5 0.95 28.1 29.4 33.6 1265

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

IEEE 45

IEEE 1580

MINIMUMBENDINGRADIUS

(mm)

37

54

63

80

85

93

102

107

114

119

134

LR, DNV, ABS, GL, BV, USCG,

Transport Canada Marine Safety

“Cable constructions, Jackets, and Inner

components tested to UL 1309 - CSA C22.2 No. 245

for Cold Bend (-40C) and Cold Impact (-35C)”

Page 27: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 25

EGFLEXIBLE SHIPBOARD INDIVIDUAL & COLLECTIVE SCREENED BRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1t 0.75 1.2 5.0 7.8 10.1 141 3t 0.75 1.2 10.5 13.2 15.9 277 4t 0.75 1.2 11.7 14.5 17.4 340 7t 0.75 1.2 14.6 17.7 20.8 505 1t 1.5 1.5 6.4 8.7 11.0 170 3t 1.5 1.5 13.1 14.8 17.7 380 4t 1.5 1.5 14.6 16.3 19.3 463 7t 1.5 1.5 18.2 19.9 23.3 719

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1p 0.75 1.2 6.5 7.4 9.7 142 2p 0.75 1.2 10.8 11.9 14.6 289 4p 0.75 1.2 13.1 14.2 17.1 294 8p 0.75 1.2 17.1 18.2 21.3 467

10p 0.75 1.2 18.7 19.8 23.2 556 12p 0.75 1.2 20.4 21.6 25.0 637 16p 0.75 1.2 22.7 24.0 27.5 795 20p 0.75 1.2 23.9 25.2 28.9 940 24p 0.75 1.2 25.6 26.9 30.9 1094 27p 0.75 1.2 27.0 28.4 32.3 1227 36p 0.75 1.2 30.7 32.1 36.5 1549 1p 1.0 1.3 6.7 7.6 9.9 155 2p 1.0 1.3 11.2 12.2 14.9 318 4p 1.0 1.3 13.5 14.6 17.5 329 8p 1.0 1.3 17.6 18.8 21.9 532

10p 1.0 1.3 19.3 20.5 23.8 635 12p 1.0 1.3 21.1 22.3 25.9 742 16p 1.0 1.3 23.5 24.7 28.5 930 20p 1.0 1.3 24.7 26.0 29.7 1090 24p 1.0 1.3 26.5 27.8 31.7 1273 27p 1.0 1.3 27.9 29.3 33.2 1402 36p 1.0 1.3 31.7 33.2 37.5 1814 1p 1.5 1.5 7.3 8.2 10.5 174 2p 1.5 1.5 12.2 13.2 15.9 380 4p 1.5 1.5 14.8 15.9 18.8 387 8p 1.5 1.5 19.4 20.6 23.9 651

10p 1.5 1.5 21.2 22.4 25.9 779 12p 1.5 1.5 23.2 24.5 28.2 913 16p 1.5 1.5 25.8 27.1 31.0 1150 20p 1.5 1.5 27.1 28.5 32.4 1357 24p 1.5 1.5 29.1 30.5 34.6 1587 27p 1.5 1.5 30.7 32.1 36.5 1777 36p 1.5 1.5 34.9 36.4 41.0 2274 1p 2.5 2.1 8.5 9.5 12.0 219 2p 2.5 2.1 14.2 15.3 18.2 522 4p 2.5 2.1 17.3 18.5 21.6 520 8p 2.5 2.1 22.8 24.0 27.6 831

10p 2.5 2.1 24.9 26.2 30.0 100212p 2.5 2.1 27.3 28.7 32.6 117816p 2.5 2.1 30.4 31.8 36.0 1600 20p 2.5 2.1 32.0 33.4 37.8 1920 24p 2.5 2.1 34.3 35.8 40.4 2253 27p 2.5 2.1 36.2 37.8 42.5 2512 36p 2.5 2.1 41.2 42.8 48.0 3265

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

MINIMUMBENDINGRADIUS

(mm)

3958688593

1001101161231291464060708895

10411411912713315042647596

104113124130138146164487386

110120130144151161170192

MINIMUMBENDINGRADIUS

(mm)

4063708344717793

Page 28: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 126

RR

CONSTRUCTIONConductor: Finely stranded annealed copperto IEC 60228 Class 5&6 & AS/NZS 1125.Available in plain or tinned.

Flame Barrier: Fire Resistant, Halogen Free, Glass Mica Tape

Insulation: LSFLEX®R-30, Cross-linked,

Polyolefinic, Thermoset, Flame Retardant,

Low Smoke, Zero Halogen (HF-90 to

IEC 60092-351) Splash resistant to oil,

skydrol, petrol, acid, sea water.

Resists ozone and UV.

Ripcord: High strength ripcord under jacket

Jacket: LSFLEX®S-50, Polyolefinic,

Flame Retardant, Low Smoke, Zero Halogen

(SHF-1 to IEC 60092-359) Splash resistant to

oil, skydrol, petrol, acid, sea water.

Resists ozone and UV.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING600/1000 Volts

CORE COLOURSTo customer specification

JACKET COLOURTo customer specification

STANDARDS

APPROVALS

APPLICATIONFlexible Power and Control cables suitable for all shipboard and marine applications, where

circuit integrity is required under fire conditions

AS/NZS 1125AS/NZS 1660.5.1AS/NZS 1660.5.2AS/NZS 1660.5.3AS/NZS 1660.5.6

IEC 60228IEC 60092-350 IEC 60092-353IEC 60331-1IEC 60331-21IEC 60332-1 IEC 60332-3-22 IEC 60754-1&2 IEC 61034-1&2

FLEXIBLE SHIPBOARDFIRE RESISTANT POWER AND CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF MINIMUM NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS INSULATION (mm) (kg/km) (Amps)

AREA (mm2) (mm) (mm) NOMINAL

1c 6 37 5.4 7.5 101 52

1c 10 43 6.4 8.7 151 72

1c 16 49 7.5 9.8 211 96

1c 25 58 9.1 11.6 315 127

1c 35 65 10.6 13.1 417 157

1c 50 74 12.2 14.9 583 196

1c 70 85 14.0 17.0 779 242

1c 95 95 16.1 19.0 1029 293

1c 120 105 18.0 21.1 1272 339

1c 150 118 20.3 23.6 1603 389

1c 185 130 22.4 26.0 1938 444

1c 240 143 25.0 28.7 2466 522

1c 300 159 27.9 31.9 3093 601

1c 400 178 31.4 35.6 3955 690

1c 500 198 35.1 39.7 4981 720

1c 630 219 39.2 43.9 6219 780

*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

IEEE 45IEEE 1580

CONDUCTORDIAMETER

(mm)

3.1

4.1

5.1

6.4

7.8

9.2

10.8

12.8

14.5

16.3

18.0

20.3

22.5

26.0

29.2

32.8

APPROX. NUMBEROF WIRES

TRIANGLE CLASS 5 CLASS 6

84 84 192

144 80 320

224 128 512

350 200 800

490 280 1120

707 400 705

991 356 990

1344 485 1340

1692 614 1690

2124 765 2123

2584 994 1470

3344 1125 1905

4144 1530 2385

5488 2035 3200

6944 1768 4010

8736 3200 5020

LR, DNV, ABS, GL, BV, USCG, TCTransport Canada Marine Safety“Cable constructions, Jackets, and Innercomponents tested to UL 1309 - CSA C22.2 No. 245 for Cold Bend (-40C) and Cold Impact (-35C)”

Page 29: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 27

RRFLEXIBLE SHIPBOARDFIRE RESISTANT POWER AND CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF MINIMUM OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS (mm) (kg/km) (Amps)

AREA (mm2) (mm) NOMINAL

2c 1.5 48 9.7 121 202c 2.5 55 11.0 163 262c 4 60 12.0 211 342c 6 66 13.2 271 442c 10 77 15.5 400 612c 16 89 17.8 563 822c 25 106 21.2 829 1082c 35 121 24.2 1105 1333c 1.5 49 9.9 143 163c 2.5 59 11.8 200 213c 4 63 12.7 256 283c 6 71 14.2 341 363c 10 82 16.4 502 503c 16 95 19.0 714 673c 25 114 22.8 1072 893c 35 129 25.9 1435 1103c 50 147 29.5 1987 1373c 70 169 33.8 2666 1693c 95 191 38.3 3539 2053c 120 214 42.8 4391 2373c 150 240 48.0 5548 2723c 185 264 52.9 6724 3113c 240 293 58.7 8537 3654c 1.5 55 11.1 171 164c 2.5 64 12.9 241 214c 4 69 13.9 313 284c 6 78 15.6 420 364c 10 91 18.2 631 504c 16 105 21.1 901 674c 25 126 25.3 1354 894c 35 144 28.8 1816 1104c 50 164 32.8 2524 1374c 70 187 37.5 3389 1694c 95 213 42.7 4525 2054c 120 238 47.7 5609 2374c 150 267 53.4 7083 2724c 185 294 58.9 8580 3115c 1.5 62 12.4 209 165c 2.5 72 14.4 294 215c 4 77 15.5 383 285c 6 87 17.4 513 365c 10 102 20.4 773 505c 16 117 23.5 1105 675c 25 141 28.2 1660 895c 35 176 32.2 2228 1105c 50 184 36.8 3118 1377c 1.5 67 13.5 241 12

10c 1.5 87 17.5 352 1112c 1.5 91 18.2 406 1014c 1.5 95 19.1 463 1016c 1.5 102 20.4 529 919c 1.5 107 21.5 612 924c 1.5 127 25.4 785 927c 1.5 131 26.2 866 933c 1.5 142 28.4 1046 937c 1.5 147 29.5 1156 97c 2.5 78 15.7 344 21

10c 2.5 101 20.3 498 2012c 2.5 105 21.1 578 1814c 2.5 111 22.2 660 1816c 2.5 118 23.7 754 1619c 2.5 126 25.3 887 1524c 2.5 148 29.6 1119 1527c 2.5 152 30.5 1239 1533c 2.5 165 33.0 1497 1537c 2.5 173 34.6 1674 15

*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

CONDUCTORDIAMETER

(mm)

1.52.12.53.14.15.16.47.81.52.12.53.14.15.16.47.89.2

10.812.814.516.318.020.31.52.12.53.14.15.16.47.89.2

10.812.814.516.318.01.52.12.53.14.15.16.47.89.21.51.51.51.51.51.51.51.51.51.52.12.12.12.12.12.12.12.12.12.1

APPROX. NUMBEROF WIRES

TRIANGLE CLASS 5 CLASS 6

- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120

- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990

1344 485 13401692 614 16902124 765 21232584 994 14703344 1125 1905

- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990

1344 485 13401692 614 16902124 765 21232584 994 1470

- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705

- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -

Page 30: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 128

BH

CONSTRUCTIONConductor: Finely stranded annealed copperto IEC 60228 Class 5&6 & AS/NZS 1125.Available in plain or tinned.

Flame Barrier: Fire Resistant, Halogen Free, Glass Mica Tape

Insulation: LSFLEX®R-30, Cross-linked,

Polyolefinic, Thermoset, Flame Retardant,

Low Smoke, Zero Halogen (HF-90 to

IEC 60092-351) Splash resistant to oil,

skydrol, petrol, acid, sea water.

Resists ozone and UV.

Separator: Polypropylene Tape

Braid/Armour Options:Tinned Copper Wire Braid (90%) Galvanized Steel Wire Braid (90%)(Also available with drain wire under the braid)

Ripcord: High strength ripcord under jacket

Jacket: LSFLEX®S-50, Polyolefinic,

Flame Retardant, Low Smoke, Zero Halogen

(SHF-1 to IEC 60092-359) Splash resistant to

oil, skydrol, petrol, acid, sea water.

Resists ozone and UV.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING600/1000 Volts

CORE COLOURSTo customer specification

JACKET COLOURTo customer specification

STANDARDS

APPROVALS

APPLICATIONFlexible Power and Control cables suitable for all shipboard and marine applications, where circuit

integrity is required under fire conditions and mechanical or EMC protection is also required.

AS/NZS 1125AS/NZS 1660.5.1AS/NZS 1660.5.2AS/NZS 1660.5.3AS/NZS 1660.5.6

IEC 60228IEC 60092-350 IEC 60092-353IEC 60331-1IEC 60331-21IEC 60332-1 IEC 60332-3-22 IEC 60754-1&2 IEC 61034-1&2

FLEXIBLE SHIPBOARD FIRE RESISTANTBRAIDED/ARMOURED POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF MINIMUM NOMINAL NOMINAL NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING OD OVER OD OVER OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS INSULATION BEDDING BRAID (mm) (kg/km) (Amps)

AREA (mm2) (mm) (mm) (mm) (mm) NOMINAL

1c 6 46 5.4 6.2 7.0 9.3 162 52

1c 10 52 6.4 7.2 8.0 10.3 210 72

1c 16 58 7.5 8.3 9.1 11.6 279 96

1c 25 66 9.1 10.0 10.8 13.3 388 127

1c 35 75 10.6 11.4 12.2 14.9 506 157

1c 50 83 12.2 13.0 13.8 16.5 676 196

1c 70 93 14.0 14.9 15.7 18.6 885 242

1c 95 104 16.1 16.9 17.7 20.8 1158 293

1c 120 115 18.0 18.8 19.1 23.0 1414 339

1c 150 127 20.3 21.1 21.9 25.4 1762 389

1c 185 138 22.4 23.2 24.1 27.6 2099 444

1c 240 152 25.0 25.8 26.6 30.3 2644 522

1c 300 165 27.9 28.8 29.1 33.0 3287 601

1c 400 187 31.4 32.2 33.0 37.4 4192 690

1c 500 206 35.1 35.9 36.7 41.3 5226 720

1c 630 229 39.2 40.0 40.8 45.8 6512 780

*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

IEEE 45IEEE 1580

CONDUCTORDIAMETER

(mm)

3.1

4.1

5.1

6.4

7.8

9.2

10.8

12.8

14.5

16.3

18.0

20.3

22.5

26.0

29.2

32.8

APPROX. NUMBEROF WIRES

TRIANGLE CLASS 5 CLASS 6

84 84 192

144 80 320

224 128 512

350 200 800

490 280 1120

707 400 705

991 356 990

1344 485 1340

1692 614 1690

2124 765 2123

2584 994 1470

3344 1125 1905

4144 1530 2385

5488 2035 3200

6944 1768 4010

8736 3200 5020

LR, DNV, ABS, GL, BV, USCG, TCTransport Canada Marine Safety“Cable constructions, Jackets, and Innercomponents tested to UL 1309 - CSA C22.2 No. 245 for Cold Bend (-40C) and Cold Impact (-35C)”

Page 31: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 29

BHFLEXIBLE SHIPBOARD FIRE RESISTANTBRAIDED/ARMOURED POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF MINIMUM NOMINAL NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING OD OVER OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS BEDDING BRAID (mm) (kg/km) (Amps)

AREA (mm2) (mm) (mm) (mm) NOMINAL

2c 1.5 57 8.2 9.0 11.5 196 20

2c 2.5 64 9.5 10.3 12.8 248 26

2c 4 68 10.3 11.1 13.6 296 34

2c 6 75 11.5 12.4 15.1 371 44

2c 10 87 13.6 14.4 17.3 514 61

2c 16 97 15.8 16.6 19.5 683 82

2c 25 115 18.9 19.7 23.1 978 108

2c 35 130 21.6 22.5 26.0 1271 133

3c 1.5 60 8.7 9.5 12.0 215 16

3c 2.5 67 10.2 110 13.5 275 21

3c 4 73 11.0 11.8 14.6 343 28

3c 6 79 12.3 13.2 15.9 430 36

3c 10 91 14.5 15.4 18.3 609 50

3c 16 104 16.9 17.7 20.8 834 67

3c 25 122 20.3 21.1 24.4 1197 89

3c 35 138 23.2 24.0 27.6 1571 110

3c 50 157 26.6 27.4 31.3 2147 137

3c 70 177 30.4 31.3 35.4 2834 169

3c 95 201 34.8 35.6 40.1 3719 205

3c 120 223 38.8 39.7 44.6 4576 237

3c 150 248 43.6 44.4 49.6 5713 272

3c 185 273 48.1 48.9 54.5 6885 311

3c 240 302 53.5 54.3 60.3 8825 365

4c 1.5 65 9.6 10.5 13.0 247 16

4c 2.5 74 11.2 12.1 14.8 328 21

4c 4 79 12.2 13.0 15.7 405 28

4c 6 87 13.7 14.5 17.4 521 36

4c 10 100 16.1 17.0 20.1 746 50

4c 16 114 18.8 19.6 22.9 1030 67

4c 25 135 22.6 23.4 26.9 1489 89

4c 35 152 25.9 26.7 30.4 1963 110

4c 50 173 29.6 30.4 34.6 2715 137

4c 70 197 34.0 34.8 39.3 3575 169

4c 95 223 38.8 39.6 44.6 4723 205

4c 120 247 43.4 44.2 49.4 5791 237

4c 150 275 48.7 49.5 55.1 7268 272

4c 185 303 53.7 54.5 60.6 8761 311

5c 1.5 71 10.8 11.6 14.3 294 16

5c 2.5 80 12.5 13.4 16.1 385 21

5c 4 87 13.6 14.5 17.4 487 28

5c 6 95 15.3 16.1 19.0 620 36

5c 10 110 18.1 18.9 22.0 896 50

5c 16 127 21.0 21.8 25.4 1256 67

5c 25 149 25.3 26.1 29.9 1822 89

5c 35 170 29.0 29.9 34.0 2441 110

5c 50 192 33.3 34.1 38.5 3318 137

7c 1.5 77 11.9 12.7 15.4 319 12

12c 1.5 100 16.1 16.9 20.0 509 10

19c 1.5 117 19.2 20.0 23.4 733 9

24c 1.5 135 22.7 23.5 27.1 915 9

27c 1.5 140 23.5 24.3 28.0 1012 9

33c 1.5 150 25.5 26.3 30.0 1191 9

37c 1.5 157 26.6 27.4 31.3 1320 9

7c 2.5 90 13.8 15.1 18.0 436 21

12c 2.5 117 18.8 20.1 23.4 700 18

19c 2.5 136 22.5 23.8 27.3 1020 15

24c 2.5 159 26.7 27.9 31.8 1288 15

27c 2.5 163 27.5 28.8 32.7 1412 15

33c 2.5 176 29.9 31.1 35.3 1686 15

37c 2.5 184 31.2 32.4 36.8 1870 15

*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

CONDUCTORDIAMETER

(mm)

1.5

2.1

2.5

3.1

4.1

5.1

6.4

7.8

1.5

2.1

2.5

3.1

4.1

5.1

6.4

7.8

9.2

10.8

12.8

14.5

16.3

18.0

20.3

1.5

2.1

2.5

3.1

4.1

5.1

6.4

7.8

9.2

10.8

12.8

14.5

16.3

18.0

1.5

2.1

2.5

3.1

4.1

5.1

6.4

7.8

9.2

1.5

1.5

1.5

1.5

1.5

1.5

1.5

2.1

2.1

2.1

2.1

2.1

2.1

2.1

APPROX. NUMBEROF WIRES

TRIANGLE CLASS 5 CLASS 6

- - -

- - -

- - -

84 84 192

144 80 320

224 128 512

350 200 800

490 280 1120

- - -

- - -

- - -

84 84 192

144 80 320

224 128 512

350 200 800

490 280 1120

707 400 705

991 356 990

1344 485 1340

1692 614 1690

2124 765 2123

2584 994 1470

3344 1125 1905

- - -

- - -

- - -

84 84 192

144 80 320

224 128 512

350 200 800

490 280 1120

707 400 705

991 356 990

1344 485 1340

1692 614 1690

2124 765 2123

2584 994 1470

- - -

- - -

- - -

84 84 192

144 80 320

224 128 512

350 200 800

490 280 1120

707 400 705

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

- - -

Page 32: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 130

ES

CONSTRUCTIONConductor: Finely stranded tinned annealed

copper to IEC 60228 Class 5&6 & AS/NZS 1125.

Flame Barrier: Fire Resistant, Halogen Free,

Glass Mica Tape

Insulation: LSFLEX®R-30, Cross-linked,

Polyolefinic, Thermoset, Flame Retardant

Low Smoke, Zero Halogen (HF-90 to

IEC 60092-351) Splash resistant to oil,

skydrol, petrol, acid, sea water.

Resists ozone and UV.

Separator: Polypropylene Tape

Screen: Aluminium/Laminate Tape

Drain Wire: Tinned annealed copper

Separator: Polypropylene Tape

Ripcord: High strength ripcord under jacket

Jacket: LSFLEX®S-50, Polyolefinic,

Flame Retardant, Low Smoke, Zero Halogen

(SHF-1 to IEC 60092-359) Splash resistant to

oil, skydrol, petrol, acid, sea water.

Resists ozone and UV.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING250 Volts

CORE COLOURSTo customer specification

JACKET COLOURTo customer specification

STANDARDS

APPROVALS

APPLICATIONFlexible Instrumentation cables suitable for all shipboard and marine applications, where circuit

integrity is required under fire conditions.

AS/NZS 1125AS/NZS 1660.5.1AS/NZS 1660.5.2AS/NZS 1660.5.3AS/NZS 1660.5.6

IEC 60228IEC 60092-350 IEC 60092-376IEC 60331-1IEC 60331-21IEC 60332-1 IEC 60332-3-22 IEC 60754-1&2 IEC 61034-1&2

IEEE 45IEEE 1580

FLEXIBLE SHIPBOARD FIRE RESISTANTCOLLECTIVE SCREENED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR OVERALL APPROX.PAIRS (p) DIAMETER DIAMETER WEIGHT

X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL

1p 0.5 0.95 9.5 104

2p 0.5 (quad formation) 0.95 10.7 128

4p 0.5 0.95 16.5 206

8p 0.5 0.95 21.2 359

10p 0.5 0.95 23.1 435

12p 0.5 0.95 25.2 514

16p 0.5 0.95 27.7 641

20p 0.5 0.95 29.2 771

24p 0.5 0.95 31.2 908

27p 0.5 0.95 32.8 1002

36p 0.5 0.95 37.2 1312

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

MINIMUMBENDINGRADIUS

(mm)

47

53

82

106

115

126

138

145

156

164

186

LR, DNV, ABS, GL, BV, USCG, TCTransport Canada Marine Safety“Cable constructions, Jackets, and Innercomponents tested to UL 1309 - CSA C22.2 No. 245 for Cold Bend (-40C) and Cold Impact (-35C)”

Page 33: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 31

ESFLEXIBLE SHIPBOARD FIRE RESISTANTCOLLECTIVE SCREENED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR OVERALL APPROX.PAIRS (p) DIAMETER DIAMETER WEIGHT

X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL

1p 0.75 1.2 10.1 118 2p 0.75 (quad formation) 1.2 11.5 154 4p 0.75 1.2 17.5 249 6p 0.75 1.2 20.0 342 8p 0.75 1.2 22.9 440

10p 0.75 1.2 24.7 523 12p 0.75 1.2 27.0 620 14p 0.75 1.2 28.5 711 16p 0.75 1.2 29.8 792 20p 0.75 1.2 31.5 955 24p 0.75 1.2 33.7 1126 27p 0.75 1.2 35.3 1245 36p 0.75 1.2 40.1 1633 1p 1.0 1.3 10.3 129 2p 1.0 (quad formation) 1.3 11.7 169 4p 1.0 1.3 18.2 275 8p 1.0 1.3 23.5 485

10p 1.0 1.3 25.5 589 12p 1.0 1.3 27.7 685 16p 1.0 1.3 30.8 892 20p 1.0 1.3 32.3 1061 24p 1.0 1.3 34.6 1252 27p 1.0 1.3 36.5 1403 36p 1.0 1.3 41.1 1819 1p 1.5 1.5 10.8 147 2p 1.5 (quad formation) 1.5 12.4 198 4p 1.5 1.5 19.3 328 8p 1.5 1.5 24.9 589

10p 1.5 1.5 27.1 718 12p 1.5 1.5 29.7 852 16p 1.5 1.5 32.8 1094 20p 1.5 1.5 34.6 1327 24p 1.5 1.5 37.0 1568 27p 1.5 1.5 39.0 175636p 1.5 1.5 44.0 2284 1p 2.5 2.1 12.3 199 2p 2.5 (quad formation) 2.1 13.9 267 4p 2.5 2.1 22.5 466 8p 2.5 2.1 29.1 840

10p 2.5 2.1 31.7 1025 12p 2.5 2.1 34.6 1216 16p 2.5 2.1 38.3 1567 20p 2.5 2.1 40.4 1904 24p 2.5 2.1 43.2 2252 27p 2.5 2.1 45.6 2522 36p 2.5 2.1 51.6 3311

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

NUMBER OF CONDUCTOR OVERALL APPROX.TRIADS (t) DIAMETER DIAMETER WEIGHT

X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL

1t 0.75 1.2 10.6 131 3t 0.75 1.2 16.5 254 4t 0.75 1.2 18.3 324 7t 0.75 1.2 22.2 513 1t 1.5 1.5 11.5 172 3t 1.5 1.5 18.2 348 4t 1.5 1.5 20.1 444 7t 1.5 1.5 24.4 714

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

MINIMUMBENDINGRADIUS

(mm)

505787

100114123135142149157168176200515891

117127138154161173182205546296

1241351481641731851952206169

112145158173191202216228258

MINIMUMBENDINGRADIUS

(mm)

538391

1115791

100122

Page 34: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 132

FJ

CONSTRUCTIONConductor: Finely stranded tinned annealedcopper to IEC 60228 Class 5&6 & AS/NZS 1125.

Flame Barrier: Fire Resistant, Halogen Free, Glass Mica Tape

Insulation: LSFLEX®R-30, Cross-linked,

Polyolefinic, Thermoset, Flame Retardant

Low Smoke, Zero Halogen (HF-90 to

IEC 60092-351) Splash resistant to oil,

skydrol, petrol, acid, sea water.

Resists ozone and UV.

Separator: Polypropylene Tape

Drain Wire: Tinned annealed copper

Screen: Aluminium/Laminate Tape

Separator: Polypropylene Tape

Braid/Armour Options:Tinned Copper Wire Braid (90%)Galvanized Steel Wire Braid (90%)

Ripcord: High strength ripcord under jacket

Jacket: LSFLEX®S-50, Polyolefinic,

Flame Retardant, Low Smoke, Zero Halogen

(SHF-1 to IEC 60092-359) Splash resistant to

oil, skydrol, petrol, acid, sea water.

Resists ozone and UV.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING250 Volts

CORE COLOURSTo customer specification

JACKET COLOURTo customer specification

STANDARDS

APPROVALS

APPLICATIONFlexible Instrumentation cables suitable for all shipboard and marine applications, where circuitintegrity is required under fire conditions and mechanical or EMC protection is also required.

AS/NZS 1125

AS/NZS 1660.5.1

AS/NZS 1660.5.2

AS/NZS 1660.5.3

AS/NZS 1660.5.6

IEC 60228

IEC 60092-350

IEC 60092-376

IEC 60331-1

IEC 60331-21

IEC 60332-3-22

IEC 60754-1&2

IEC 61034-1&2

FLEXIBLE SHIPBOARD FIRE RESISTANT COLLECTIVE SCREENEDBRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1p 0.5 0.95 7.3 8.1 10.5 156

2p 0.5 (quad form) 0.95 8.4 9.2 11.7 185

4p 0.5 0.95 13.8 14.6 17.5 290

8p 0.5 0.95 18.1 18.9 22.0 458

10p 0.5 0.95 19.8 20.6 23.9 543

12p 0.5 0.95 21.7 22.5 26.1 634

16p 0.5 0.95 24.2 25.0 28.7 786

20p 0.5 0.95 25.5 26.3 30.0 911

24p 0.5 0.95 27.3 28.1 32.1 1058

27p 0.5 0.95 28.8 29.6 33.8 1085

36p 0.5 0.95 32.8 33.6 38.0 1384

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

IEEE 45

IEEE 1580

MINIMUMBENDINGRADIUS

(mm)

52

58

88

110

120

130

143

150

160

169

190

LR, DNV, ABS, GL, BV, USCG, TC

Transport Canada Marine Safety

“Cable constructions, Jackets, and Inner

components tested to UL 1309 - CSA C22.2 No. 245

for Cold Bend (-40C) and Cold Impact (-35C)”

Page 35: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 33

FJFLEXIBLE SHIPBOARD FIRE RESISTANT COLLECTIVE SCREENEDBRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1t 0.75 1.2 8.1 9.1 11.6 180 3t 0.75 1.2 13.6 14.6 17.6 337 4t 0.75 1.2 15.1 16.2 19.1 407 7t 0.75 1.2 18.7 19.9 23.2 625 1t 1.5 1.5 8.9 9.9 12.4 217 3t 1.5 1.5 15.0 16.1 19.0 428 4t 1.5 1.5 16.6 17.8 20.9 533 7t 1.5 1.5 20.6 21.9 25.4 834

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1p 0.75 1.2 7.6 8.6 10.9 173 2p 0.75 (quad form) 1.2 8.8 9.8 12.3 210 4p 0.75 1.2 14.3 15.4 18.3 330 8p 0.75 1.2 19.2 20.4 23.7 548

10p 0.75 1.2 21.0 22.2 25.7 651 12p 0.75 1.2 23.0 24.3 28.0 761 14p 0.75 1.2 24.2 25.5 29.3 847 16p 0.75 1.2 25.6 26.9 30.9 871 20p 0.75 1.2 27.0 28.3 32.3 1023 24p 0.75 1.2 28.9 30.3 34.5 1193 27p 0.75 1.2 30.6 32.0 36.4 1329 36p 0.75 1.2 34.8 36.3 40.9 1828 1p 1.0 1.3 7.8 8.8 11.1 184 2p 1.0 (quad form) 1.3 9.1 10.1 12.6 226 4p 1.0 1.3 15.0 16.1 19.0 360 8p 1.0 1.3 19.7 20.9 24.3 596

10p 1.0 1.3 21.6 22.8 26.4 711 12p 1.0 1.3 23.7 25.0 28.7 831 16p 1.0 1.3 26.3 27.7 31.6 1039 20p 1.0 1.3 27.8 29.2 33.1 1218 24p 1.0 1.3 29.8 31.2 35.4 1420 27p 1.0 1.3 31.5 32.9 37.3 1580 36p 1.0 1.3 35.8 37.4 42.2 2040 1p 1.5 1.5 8.3 9.3 11.8 208 2p 1.5 (quad form) 1.5 9.7 10.7 13.2 259 4p 1.5 1.5 16.1 17.2 20.3 428 8p 1.5 1.5 21.2 22.4 25.9 719

10p 1.5 1.5 23.2 24.4 28.2 860 12p 1.5 1.5 25.4 26.7 30.5 918 16p 1.5 1.5 28.3 29.7 33.8 1268 20p 1.5 1.5 29.8 31.2 35.4 1495 24p 1.5 1.5 32.0 33.4 37.8 1749 27p 1.5 1.5 33.8 35.3 39.9 1948 36p 1.5 1.5 38.5 40.1 45.1 2523 1p 2.5 2.1 9.6 10.6 13.1 263 2p 2.5 (quad form) 2.1 11.2 12.3 15.0 344 4p 2.5 2.1 18.8 20.0 23.3 572 8p 2.5 2.1 24.9 26.2 29.9 980

10p 2.5 2.1 27.2 28.6 32.5 1094 12p 2.5 2.1 29.9 31.3 35.5 1384 16p 2.5 2.1 33.3 34.7 39.3 1771 20p 2.5 2.1 35.1 36.6 41.2 2103 24p 2.5 2.1 37.6 39.2 44.0 2466 27p 2.5 2.1 39.8 41.4 46.4 2748 36p 2.5 2.1 45.3 47.0 52.4 3571

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

MINIMUMBENDINGRADIUS

(mm)

546291

118129140146154161172182204556395

1211321441581661771862115966

1021301411521691771891992256675

117150163177197206220232262

MINIMUMBENDINGRADIUS

(mm)

588895

1166295

104127

Page 36: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 134

FC

CONSTRUCTIONConductor: Finely stranded tinned annealed

copper to IEC 60228 Class 5&6 & AS/NZS 1125.

Flame Barrier: Fire Resistant, Halogen Free,

Glass Mica Tape

Insulation: LSFLEX®R-30, Cross-linked,

Polyolefinic, Thermoset, Flame Retardant

Low Smoke, Zero Halogen (HF-90 to

IEC 60092-351) Splash resistant to oil,

skydrol, petrol, acid, sea water.

Resists ozone and UV.

Separator: Polypropylene Tape

Screen: Individual and Collective

Aluminium/Laminate Tape

Drain Wire: Tinned annealed copper

Separator: Polypropylene Tape

Ripcord: High strength ripcord under jacket

Jacket: LSFLEX®S-50, Polyolefinic,

Flame Retardant, Low Smoke, Zero Halogen

(SHF-1 to IEC 60092-359) Splash resistant to

oil, skydrol, petrol, acid, sea water.

Resists ozone and UV.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING250 Volts

CORE COLOURSTo customer specification

JACKET COLOURTo customer specification

STANDARDS

APPROVALS

APPLICATIONFlexible Instrumentation cables suitable for all shipboard and marine applications, where

circuit integrity is required under fire conditions.

AS/NZS 1125AS/NZS 1660.5.1AS/NZS 1660.5.2AS/NZS 1660.5.3AS/NZS 1660.5.6

IEC 60228IEC 60092-350 IEC 60092-376IEC 60331-1IEC 60331-21IEC 60332-1 IEC 60332-3-22 IEC 60754-1&2 IEC 61034-1&2

FLEXIBLE SHIPBOARD FIRE RESISTANTINDIVIDUAL & COLLECTIVE SCREENEDINSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR OVERALL APPROX.PAIRS (p) DIAMETER DIAMETER WEIGHT

X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL

1p 0.5 0.95 9.5 101

2p 0.5 0.95 15.1 188

4p 0.5 0.95 18.0 257

8p 0.5 0.95 23.2 451

10p 0.5 0.95 25.3 547

12p 0.5 0.95 27.4 635

16p 0.5 0.95 30.3 812

20p 0.5 0.95 31.9 979

24p 0.5 0.95 34.1 1155

27p 0.5 0.95 35.8 1277

36p 0.5 0.95 40.6 1674

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

IEEE 45IEEE 1580

MINIMUMBENDINGRADIUS

(mm)

47

75

90

116

126

137

151

159

170

194

203

LR, DNV, ABS, GL, BV, USCG,Transport Canada Marine Safety“Cable constructions, Jackets, and Innercomponents tested to UL 1309 - CSA C22.2 No. 245 for Cold Bend (-40C) and Cold Impact (-35C)”

Page 37: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 35

FCFLEXIBLE SHIPBOARD FIRE RESISTANTINDIVIDUAL & COLLECTIVE SCREENEDINSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR OVERALL APPROX.PAIRS (p) DIAMETER DIAMETER WEIGHT

X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL

1p 0.75 1.2 10.1 115 2p 0.75 1.2 15.9 213 4p 0.75 1.2 19.1 296 8p 0.75 1.2 24.6 525

10p 0.75 1.2 26.9 640 12p 0.75 1.2 29.3 758 16p 0.75 1.2 32.4 971 20p 0.75 1.2 34.2 1173 24p 0.75 1.2 36.5 1383 27p 0.75 1.2 38.4 1532 36p 0.75 1.2 43.5 2009 1p 1.0 1.3 10.3 125 2p 1.0 1.3 16.3 234 4p 1.0 1.3 19.7 339 8p 1.0 1.3 25.4 603

10p 1.0 1.3 27.5 722 12p 1.0 1.3 30.0 856 16p 1.0 1.3 32.2 1100 20p 1.0 1.3 35.0 1333 24p 1.0 1.3 37.4 1574 27p 1.0 1.3 39.5 1763 36p 1.0 1.3 44.8 2313 1p 1.5 1.5 10.8 143 2p 1.5 1.5 17.3 275 4p 1.5 1.5 20.5 392 8p 1.5 1.5 26.9 710

10p 1.5 1.5 29.3 867 12p 1.5 1.5 32.0 1028 16p 1.5 1.5 35.4 1324 20p 1.5 1.5 37.3 1608 24p 1.5 1.5 39.9 1901 27p 1.5 1.5 42.1 2130 36p 1.5 1.5 47.7 2795 1p 2.5 2.1 12.3 193 2p 2.5 2.1 19.8 367 4p 2.5 2.1 23.8 536 8p 2.5 2.1 31.1 988

10p 2.5 2.1 33.9 1206 12p 2.5 2.1 37.0 1431 16p 2.5 2.1 40.9 1846 20p 2.5 2.1 43.0 2246 24p 2.5 2.1 46.0 2658 27p 2.5 2.1 48.6 2976 36p 2.5 2.1 55.0 3910

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

NUMBER OF CONDUCTOR OVERALL APPROX.TRIADS (t) DIAMETER DIAMETER WEIGHT

X CROSS SECTION (mm) (mm) (kg/km)AREA (mm2) NOMINAL1t 0.75 1.2 10.6 125 3t 0.75 1.2 17.9 296 4t 0.75 1.2 19.8 377 7t 0.75 1.2 23.9 599 1t 1.5 1.5 11.5 164 3t 1.5 1.5 19.3 391 4t 1.5 1.5 21.4 502 7t 1.5 1.5 26.1 822

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

MINIMUMBENDINGRADIUS

(mm)

507995

123134146162171182192216518198

1271371501611751871972245486

1021341461601771861992102386198

119155169185204215230243275

MINIMUMBENDINGRADIUS

(mm)538999

1195796

107130

Page 38: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 136

FL

CONSTRUCTIONConductor: Finely stranded tinned annealedcopper to IEC 60228 Class 5&6 & AS/NZS 1125.

Flame Barrier: Fire Resistant, Halogen Free, Glass Mica Tape

Insulation: LSFLEX®R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant Low Smoke, Zero Halogen (HF-90 to IEC 60092-351) Splash resistant to oil, skydrol, petrol, acid, sea water. Resists ozone and UV.

Separator: Polypropylene Tape

Drain Wire: Tinned annealed copper

Screen: Individual and CollectiveAluminium/Laminate Tape

Separator: Polypropylene Tape

Braid/Armour Options:Tinned Copper Wire Braid (90%) Galvanized Steel Wire Braid (90%)

Ripcord: High strength ripcord under jacket

Jacket: LSFLEX®S-50, Polyolefinic, Flame Retardant, Low Smoke, Zero Halogen (SHF-1 to IEC 60092-359) Splash resistant tooil, skydrol, petrol, acid, sea water. Resists ozone and UV.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING250 Volts

CORE COLOURSTo customer specification

JACKET COLOURTo customer specification

STANDARDS

APPROVALS

APPLICATIONFlexible Instrumentation cables suitable for all shipboard and marine applications, where circuit

integrity is required under fire conditions and mechanical or EMC protection is also required.

AS/NZS 1125

AS/NZS 1660.5.1

AS/NZS 1660.5.2

AS/NZS 1660.5.3

AS/NZS 1660.5.6

IEC 60228

IEC 60092-350

IEC 60092-376

IEC 60331-1

IEC 60331-21

IEC 60332-1

IEC 60332-3-22

IEC 60754-1&2

IEC 61034-1&2

FLEXIBLE SHIPBOARD FIRE RESISTANTINDIVIDUAL & COLLECTIVE SCREENED BRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1p 0.5 0.95 7.3 8.1 10.4 156

2p 0.5 0.95 12.7 13.5 16.2 340

4p 0.5 0.95 15.4 16.2 19.1 341

8p 0.5 0.95 20.2 21.0 24.3 559

10p 0.5 0.95 22.0 22.8 26.4 665

12p 0.5 0.95 24.1 24.9 28.7 775

16p 0.5 0.95 26.8 27.6 31.6 965

20p 0.5 0.95 28.3 29.1 33.0 1125

24p 0.5 0.95 30.3 31.1 35.2 1309

27p 0.5 0.95 32.0 32.8 37.1 1465

36p 0.5 0.95 36.4 37.2 41.9 1876

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

IEEE 45

IEEE 1580

MINIMUMBENDINGRADIUS

(mm)

52

81

96

121

132

143

158

165

176

186

210

LR, DNV, ABS, GL, BV, USCG,

Transport Canada Marine Safety

“Cable constructions, Jackets, and Inner

components tested to UL 1309 - CSA C22.2 No. 245

for Cold Bend (-40C) and Cold Impact (-35C)”

Page 39: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 37

FLFLEXIBLE SHIPBOARD FIRE RESISTANTINDIVIDUAL & COLLECTIVE SCREENED BRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1t 0.75 1.2 8.5 9.6 12.1 193 3t 0.75 1.2 15.4 16.7 19.8 419 4t 0.75 1.2 17.2 18.4 21.5 506 7t 0.75 1.2 21.1 22.5 26.0 776 1t 1.5 1.5 9.3 10.4 12.9 233 3t 1.5 1.5 16.8 18.1 21.2 522 4t 1.5 1.5 18.7 20.0 23.3 650 7t 1.5 1.5 23.1 24.5 28.2 1012

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1p 0.75 1.2 7.5 8.6 10.9 171 2p 0.75 1.2 13.2 14.3 17.2 398 4p 0.75 1.2 16.0 17.3 20.4 395 8p 0.75 1.2 21.1 22.4 25.9 653

10p 0.75 1.2 23.1 24.4 28.2 778 12p 0.75 1.2 25.3 26.7 30.4 895 16p 0.75 1.2 28.1 29.6 33.8 1137 20p 0.75 1.2 29.6 31.1 35.3 1331 24p 0.75 1.2 31.7 33.3 37.7 1552 27p 0.75 1.2 33.5 35.1 39.7 1726 36p 0.75 1.2 38.1 39.8 44.8 2227 1p 1.0 1.3 7.7 8.8 11.1 182 2p 1.0 1.3 13.5 14.7 17.6 431 4p 1.0 1.3 16.5 17.7 20.8 432 8p 1.0 1.3 21.6 23.0 26.5 723

10p 1.0 1.3 23.7 25.1 28.8 864 12p 1.0 1.3 26.0 27.4 31.1 1011 16p 1.0 1.3 28.9 30.4 34.5 1270 20p 1.0 1.3 30.4 31.9 36.3 1511 24p 1.0 1.3 32.6 34.2 38.5 1747 27p 1.0 1.3 34.4 36.1 40.6 1945 36p 1.0 1.3 39.2 40.9 45.9 2516 1p 1.5 1.5 8.2 9.3 11.8 209 2p 1.5 1.5 14.3 15.5 18.4 492 4p 1.5 1.5 17.5 18.8 21.9 493 8p 1.5 1.5 23.1 24.5 28.2 850

10p 1.5 1.5 25.3 26.7 30.4 1005 12p 1.5 1.5 27.7 29.2 33.1 1179 16p 1.5 1.5 30.8 32.3 36.7 1517 20p 1.5 1.5 32.5 34.0 38.4 1781 24p 1.5 1.5 34.8 36.4 41.0 2085 27p 1.5 1.5 36.8 38.4 43.2 2323 36p 1.5 1.5 41.8 43.6 48.8 3012 1p 2.5 2.1 9.5 10.6 13.1 264 2p 2.5 2.1 16.5 17.8 20.9 664 4p 2.5 2.1 20.2 21.6 24.9 648 8p 2.5 2.1 26.8 28.2 32.2 1134

10p 2.5 2.1 29.3 30.8 35.0 1366 12p 2.5 2.1 32.2 33.7 38.1 1604 16p 2.5 2.1 35.8 37.4 42.2 1056 20p 2.5 2.1 37.7 39.4 44.2 2446 24p 2.5 2.1 40.5 42.2 47.4 2892 27p 2.5 2.1 42.7 44.5 49.7 3201 36p 2.5 2.1 48.7 50.6 56.4 4186

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

MINIMUMBENDINGRADIUS

(mm)

5486

1021301411521691761881982245588

1041331441571731821932032295992

11014115216618419220521624466

104124161175190211221237248282

MINIMUMBENDINGRADIUS

(mm)

6099

10813064

106117141

Page 40: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 138

FLEXIBLE SHOREPOWER0.6/1kV 110°C

EZ

CONSTRUCTIONConductor: Finely stranded annealed copper

to IEC 60228 Class 5&6 & AS/NZS 1125.

Available in plain or tinned.

Insulation: LSFLEX®R-30 (X-HF-110)

Cross-linked, Thermoset, Elastomeric,

Flame Retardant, Low Smoke, Zero Halogen

Splash resistant to oil, skydrol, petrol, acid,

sea water. Resists ozone and UV.

Ripcord: High strength ripcord under jacket

Jacket: E-Rubber®N-40, Elastomeric Rubber,

Splash resistant to oil, skydrol, petrol, acid,

sea water. Resists ozone and UV.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING600/1000 Volts

CORE IDENTIFICATIONTo customer specification

JACKET COLOURTo customer specification

STANDARDS

APPLICATIONFlexible Shorepower cables suitable for all shipboard and marine applications.

AS/NZS 1125

AS/NZS 5000.1

AS/NZS 3191

NUMBER OF MINIMUM OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS (mm) (kg/km) (Amps)

AREA (mm2) (mm) NOMINAL

2c 1.5 27 9.1 105 28

2c 2.5 32 10.8 151 38

2c 4 35 11.8 197 50

2c 6 40 13.2 261 63

2c 10 52 17.5 460 88

2c 16 60 19.9 633 116

2c 25 72 24.1 950 154

2c 35 82 27.5 1265 190

*AS/NZS 3008, Table 11/14 (Fixed – Unenclosed spaced) 110°C operating temperature, 40°C ambient temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

CONDUCTORDIAMETER

(mm)

1.5

2.1

2.5

3.1

4.1

5.1

6.4

7.8

APPROX. NUMBEROF WIRES

TRIANGLE CLASS 5 CLASS 6

- - -

- - -

- - -

84 84 192

144 80 320

224 128 512

350 200 800

490 280 1120

Page 41: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

FLEXIBLE SHOREPOWER0.6/1kV 110°C

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 39

EZ

NUMBER OF MINIMUM OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS (mm) (kg/km) (Amps)

AREA (mm2) (mm) NOMINAL

3c 1.5 29 9.8 126 24

3c 2.5 34 11.3 177 32

3c 4 37 12.4 236 42

3c 6 42 14.1 324 54

3c 10 56 18.6 564 75

3c 16 63 21.1 788 99

3c 25 77 25.6 1187 131

3c 35 87 29.1 1588 162

3c 50 100 33.3 2203 204

3c 70 114 38.0 2943 255

3c 95 130 43.4 3925 306

3c 120 145 48.3 4857 360

3c 150 162 54.1 6138 413

3c 185 179 59.6 7451 470

3c 240 199 66.3 9454 599

3c 300 218 72.7 11788 638

4c 1.5 32 10.7 153 24

4c 2.5 37 12.4 216 32

4c 4 41 13.8 296 42

4c 6 47 15.7 406 54

4c 10 61 20.4 698 75

4c 16 70 23.2 980 99

4c 25 85 28.3 1491 131

4c 35 97 32.2 1996 162

4c 50 110 36.8 2774 204

4c 70 127 42.2 3727 255

4c 95 144 48.0 4967 306

4c 120 161 53.6 6164 360

4c 150 181 60.2 7808 413

4c 185 199 66.3 9462 470

4c 240 221 73.8 12038 559

4c 300 242 80.8 15015 638

5c 1.5 35 11.8 191 24

5c 2.5 42 13.9 275 32

5c 4 46 15.2 367 42

5c 6 52 17.3 501 54

5c 10 67 22.6 852 75

5c 16 77 25.6 1208 99

5c 25 94 31.2 1832 131

5c 35 107 35.8 2466 162

5c 50 123 41.1 3441 204

*AS/NZS 3008, Table 11/14 (Fixed – Unenclosed spaced) 110°C operating temperature, 40°C ambient temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions. Triangle Cables is not liable for any errors, omissions, etc., and reserves the right to modify specifications at any time

CONDUCTORDIAMETER

(mm)

1.5

2.1

2.5

3.1

4.1

5.1

6.4

7.8

9.2

10.8

12.8

14.5

16.3

18.0

20.3

22.5

1.5

2.1

2.5

3.1

4.1

5.1

6.4

7.8

9.2

10.8

12.8

14.5

16.3

18.0

20.3

22.5

1.5

2.1

2.5

3.1

4.1

5.1

6.4

7.8

9.2

APPROX. NUMBEROF WIRES

TRIANGLE CLASS 5 CLASS 6

- - -

- - -

- - -

84 84 192

144 80 320

224 128 512

350 200 800

490 280 1120

707 400 705

991 356 990

1344 485 1340

1692 614 1690

2124 765 2123

2584 994 1470

3344 1125 1905

4144 1530 2385

- - -

- - -

- - -

84 84 192

144 80 320

224 128 512

350 200 800

490 280 1120

707 400 705

991 356 990

1344 485 1340

1692 614 1690

2124 765 2123

2584 994 1470

3344 1125 1905

4144 1530 2385

- - -

- - -

- - -

84 84 192

144 80 320

224 128 512

350 200 800

490 280 1120

707 400 705

Page 42: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

UP

CONSTRUCTIONConductor: Finely stranded annealed copper

to IEC 60228 Class 5&6 & AS/NZS 1125.

Available in plain or tinned.

Insulation: LSFLEX®R-30, Cross-linked,

Polyolefinic, Thermoset, Flame Retardant,

Low Smoke, Zero Halogen (HF-90 to

IEC 60092-351) Splash resistant to oil,

skydrol, petrol, acid, sea water.

Resists ozone and UV.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING600/1000 Volts

CORE COLOURSTo customer specification

STANDARDS

APPROVALS

APPLICATIONFlexible Single Insulated Power Cables suitable for all shipboard and marine applications

AS/NZS 1125

AS/NZS 1660.5.1

AS/NZS 1660.5.2

AS/NZS 1660.5.3

AS/NZS 1660.5.6

IEC 60228

IEC 60092-350

IEC 60092-353

IEC 60332-1

IEC 60332-3-22

IEC 60754-1&2

IEC 61034-1&2

IEEE 45

IEEE 1580

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 140

FLEXIBLE SHIPBOARDSWITCHBOARD/PANEL WIRE0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF MINIMUM OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS (mm) (kg/km) (Amps)

AREA (mm2) (mm) NOMINAL

1c 0.75 7 2.6 13 16

1c 1.0 7 2.7 15 20

1c 1.5 7 2.9 20 26

1c 2.5 9 3.5 30 32

1c 4 10 3.9 44 43

1c 6 11 4.5 63 52

1c 10 14 5.6 99 72

1c 16 16 6.6 150 96

1c 25 21 8.3 236 127

1c 35 24 9.7 326 157

1c 50 28 11.3 471 196

1c 70 33 13.1 637 242

1c 95 38 15.2 865 293

1c 120 43 17.1 1076 339

1c 150 48 19.3 1370 389

1c 185 54 21.4 1667 444

1c 240 60 23.9 2040 522

1c 300 66 26.4 2654 601

1c 400 76 30.3 3509 690

1c 500 85 33.9 4439 720

1c 630 95 38.0 5585 780

*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions. Triangle Cables is not liable for any errors, omissions, etc., and reserves the right to modify specifications at any time

CONDUCTORDIAMETER

(mm)

1.2

1.3

1.5

2.1

2.5

3.1

4.1

5.1

6.4

7.8

9.2

10.8

12.8

14.5

16.3

18.0

20.3

22.5

26.0

29.2

32.8

APPROX. NUMBEROF WIRES

TRIANGLE CLASS 5 CLASS 6

- - -

- - -

- - -

- - -

- - -

84 84 192

144 80 320

224 128 512

350 200 800

490 280 1120

707 400 705

991 356 990

1344 485 1340

1692 614 1690

2124 765 2123

2584 994 1470

3344 1125 1905

4144 1530 2385

5488 2035 3200

6944 1768 4010

8736 3200 5020

LR, DNV, ABS, GL, BV, RAN, USCG,

Page 43: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

OFFSHORE CABLES

POWER AND CONTROL

Braided/Armoured PJ 42

INSTRUMENTATION

Collective screened

Braided/Armoured RB 44

Individual and collective screened

Braided/Armoured FZ 46

POWER AND CONTROL – F i re Resistant

Braided/Armoured HT 48

INSTRUMENTATION – F i re Resistant

Collective screened

Braided/Armoured FK 50

Individual and collective screened

Braided/Armoured FE 52

SWITCHBOARD/PANEL WIRE UP 54

Page 44: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 142

PJ

CONSTRUCTIONConductor: Finely stranded annealed copperto IEC 60228 Class 5&6 & AS/NZS 1125.Available in plain or tinned.

Insulation: LSFLEX®R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant, Low Smoke, Zero Halogen (HF-90 to IEC 60092-351) Splash resistant to oil, skydrol, petrol, acid, sea water. Resists ozone and UV.

Ripcord: High strength ripcord under bedding in multicores

Bedding: LSFLEX®S-50 Low Smoke, Zero Halogen (pressure extruded)

Braid/Armour Options:Galvanized Steel Wire Braid (90%)Tinned Copper Wire Braid (90%) (Also available with drain wire under the braid)

Ripcord: High strength ripcord under jacket

Jacket: LSFLEX®S-50, Polyolefinic, Flame Retardant, Low Smoke, Zero Halogen (SHF-1 to IEC 60092-359) Splash resistant tooil, skydrol, petrol, acid, sea water. Resists ozone and UV. SHF-2 also available.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING600/1000 Volts

CORE COLOURSTo customer specification

JACKET COLOURTo customer specification

STANDARDS

APPROVALS

APPLICATIONFlexible Power and Control cables suitable for all offshore applications, where mechanical

or EMC protection is required.

AS/NZS 1125AS/NZS 1660.5.1AS/NZS 1660.5.2AS/NZS 1660.5.3AS/NZS 1660.5.6

IEC 60228IEC 60092-350 IEC 60092-353IEC 60332-1 IEC 60332-3-22 IEC 60754-1&2 IEC 61034-1&2

NEK 606

FLEXIBLE OFFSHORE BRAIDED/ARMOURED POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF MINIMUM NOMINAL NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING OD OVER OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS BEDDING BRAID (mm) (kg/km) (Amps)

AREA (mm2) (mm) (mm) (mm) NOMINAL

1c 10 44 7.8 8.6 11.1 210 72

1c 16 49 8.8 9.6 12.3 281 96

1c 25 58 10.7 11.5 14.4 401 127

1c 35 63 12.1 12.9 15.9 512 157

1c 50 72 13.9 14.7 17.9 696 196

1c 70 80 15.7 16.5 20.0 905 242

1c 95 89 17.9 18.7 22.2 1176 293

1c 120 97 19.8 20.6 24.3 1431 339

1c 150 108 22.2 23.0 27.0 1789 389

1c 185 118 24.5 25.3 29.6 2150 444

1c 240 130 27.2 28.0 32.5 2708 522

1c 300 141 30.3 30.4 35.2 3355 601

1c 400 160 33.9 34.7 40.0 4292 690

1c 500 176 37.7 38.5 44.1 5348 720

1c 630 195 42.0 42.8 48.8 6659 780

*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

IEEE 45IEEE 1580

CONDUCTORDIAMETER

(mm)

4.1

5.1

6.4

7.8

9.2

10.8

12.8

14.5

16.3

18.0

20.3

22.5

26.0

29.2

32.8

APPROX. NUMBEROF WIRES

TRIANGLE CLASS 5 CLASS 6

144 80 320

224 128 512

350 200 800

490 280 1120

707 400 705

991 356 990

1344 485 1340

1692 614 1690

2124 765 2123

2584 994 1470

3344 1125 1905

4144 1530 2385

5488 2035 3200

6944 1768 4010

8736 3200 5020

LR, DNV, ABS, GL, BV, USCG, TCTransport Canada Marine Safety“Cable constructions, Jackets, and Innercomponents tested to UL 1309 - CSA C22.2 No. 245 for Cold Bend (-40C) and Cold Impact (-35C)”

Page 45: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 43

PJFLEXIBLE OFFSHOREBRAIDED/ARMOURED POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

NUMBER OF MINIMUM NOMINAL NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING OD OVER OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS BEDDING BRAID (mm) (kg/km) (Amps)

AREA (mm2) (mm) (mm) (mm) NOMINAL2c 1.5 46 8.1 8.9 11.6 169 202c 2.5 51 9.3 10.1 12.8 211 262c 4 55 10.3 11.1 13.9 260 342c 6 61 11.5 12.3 15.3 328 442c 10 71 13.7 14.5 17.7 464 612c 16 80 15.7 16.5 19.9 623 822c 25 95 19.2 20.0 23.7 901 1082c 35 107 22.1 22.9 26.8 1182 1333c 1.5 48 8.6 9.4 12.1 190 163c 2.5 53 9.9 10.7 13.4 243 213c 4 59 10.9 11.7 14.7 311 283c 6 64 12.2 13.0 16.0 392 363c 10 74 14.6 15.4 18.6 567 503c 16 84 16.6 17.4 20.9 776 673c 25 102 20.6 21.4 25.4 1158 893c 35 115 23.7 24.5 28.7 1529 1103c 50 130 27.2 28.0 32.5 2090 1373c 70 148 31.2 32.0 37.0 2784 1693c 95 168 35.6 36.4 41.9 3672 2053c 120 186 39.8 40.6 46.4 4506 2373c 150 208 44.9 45.7 52.0 5680 2723c 185 229 49.5 50.3 57.2 6857 3113c 240 253 55.2 56.0 62.4 8682 3654c 1.5 51 9.3 10.1 12.8 218 164c 2.5 59 10.9 11.7 14.7 293 214c 4 63 11.9 12.7 15.7 366 284c 6 69 13.3 14.1 17.3 475 364c 10 81 15.9 16.7 20.2 694 504c 16 92 18.5 19.3 23.0 968 674c 25 110 22.7 23.5 27.5 1427 894c 35 126 26.1 26.9 31.5 1909 1104c 50 142 30.4 30.8 35.6 2639 1374c 70 163 34.7 35.5 40.7 3514 1694c 95 185 39.6 40.4 46.2 4656 2054c 120 206 44.5 45.3 51.6 5759 2374c 150 230 49.9 50.7 57.5 7240 2724c 185 254 55.3 56.1 63.4 8762 3115c 1.5 56 10.4 11.2 13.9 254 165c 2.5 63 12.0 12.8 15.8 338 215c 4 68 13.1 13.9 17.1 434 285c 6 76 14.9 15.7 18.9 563 365c 10 88 17.8 18.6 22.1 830 505c 16 102 20.6 21.4 25.4 1175 675c 25 122 25.4 26.2 30.4 1736 895c 35 139 29.2 30.0 34.8 2325 1105c 50 159 33.8 34.6 39.8 3238 1375c 70 181 38.8 39.6 45.4 4313 1695c 95 206 44.5 45.3 51.6 5735 2055c 120 230 49.8 50.6 57.4 7069 2375c 150 258 56.0 56.8 64.4 8938 2725c 185 284 62.0 62.8 70.9 10809 3115c 240 315 69.1 69.9 78.8 13734 3657c 1.5 62 11.3 12.5 15.4 341 12

10c 1.5 75 14.3 15.5 18.7 462 1112c 1.5 77 14.8 16.0 19.3 511 1014c 1.5 81 15.6 16.8 20.2 572 1016c 1.5 85 16.5 17.7 21.1 626 919c 1.5 89 17.5 18.7 22.2 708 921c 1.5 94 18.6 19.8 23.5 777 924c 1.5 103 20.5 21.7 25.7 889 927c 1.5 105 21.1 22.3 26.3 958 933c 1.5 113 22.7 23.9 28.2 1119 937c 1.5 117 23.8 25.0 29.3 1224 97c 2.5 70 13.1 14.3 17.5 452 21

10c 2.5 85 16.6 17.8 21.3 617 2012c 2.5 89 17.5 18.7 22.2 697 1814c 2.5 93 18.4 19.6 23.3 783 1816c 2.5 98 19.5 20.7 24.4 863 1619c 2.5 104 20.8 22.0 25.9 993 1521c 2.5 109 22.0 23.2 27.2 1077 1524c 2.5 119 24.3 25.5 29.8 1231 1527c 2.5 122 25.0 26.2 30.5 1335 1533c 2.5 132 27.2 28.4 32.9 1579 1537c 2.5 137 28.2 29.4 34.2 1735 15

CONDUCTORDIAMETER

(mm)

1.52.12.53.14.15.16.47.81.52.12.53.14.15.16.47.89.2

10.812.814.516.318.020.31.52.12.53.14.15.16.47.89.2

10.812.814.516.318.01.52.12.53.14.15.16.47.89.2

10.812.814.516.318.020.31.51.51.51.51.51.51.51.51.51.51.52.12.12.12.12.12.12.12.12.12.12.1

APPROX. NUMBEROF WIRES

TRIANGLE CLASS 5 CLASS 6- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120

- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990

1344 485 13401692 614 16902124 765 21232584 994 14703344 1125 1905

- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990

1344 485 13401692 614 16902124 765 21232584 994 1470

- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990

1344 485 13401692 614 16902124 765 21232584 994 14703344 1125 1905

- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -

Page 46: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 144

RB

CONSTRUCTIONConductor: Finely stranded tinned annealedcopper to IEC 60228 Class 5&6 & AS/NZS 1125.

Insulation: LSFLEX®R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant Low Smoke, Zero Halogen (HF-90 to IEC 60092-351) Splash resistant to oil, skydrol, petrol, acid, sea water. Resists ozone and UV.

Separator: Polypropylene Tape

Screen: Aluminium/Laminate Tape

Drain Wire: Tinned annealed copper

Separator: Polypropylene Tape

Ripcord: High strength ripcord under bedding

Bedding: LSFLEX®S-50 Low Smoke, Zero Halogen (pressure extruded)

Braid/Armour Options:Galvanized Steel Wire Braid (90%)Tinned Copper Wire Braid (90%) (Also available with drain wire under the braid)

Ripcord: High strength ripcord under jacket

Jacket: LSFLEX®S-50, Polyolefinic, Flame Retardant, Low Smoke, Zero Halogen (SHF-1 to IEC 60092-359) Splash resistant tooil, skydrol, petrol, acid, sea water. Resists ozone and UV. SHF-2 also available.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING250 Volts

CORE COLOURSTo customer specification

JACKET COLOURTo customer specification

STANDARDS

APPROVALS

APPLICATIONFlexible Instrumentation cables suitable for all offshore applications, where mechanical or

EMC protection is required.

AS/NZS 1125AS/NZS 1660.5.1AS/NZS 1660.5.2AS/NZS 1660.5.3AS/NZS 1660.5.6

IEC 60228IEC 60092-350 IEC 60092-376IEC 60332-1 IEC 60332-3-22 IEC 60754-1&2 IEC 61034-1&2

NEK 606

FLEXIBLE OFFSHORE COLLECTIVE SCREENED BRAIDED/ARMOUREDINSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1p 0.5 0.95 7.8 8.7 11.2 146

2p 0.5(quad form) 0.95 8.6 9.5 12.2 173

4p 0.5 0.95 12.9 13.8 16.9 278

8p 0.5 0.95 16.2 17.1 20.6 404

10p 0.5 0.95 17.6 18.5 22.0 463

12p 0.5 0.95 19.1 20.0 23.7 528

16p 0.5 0.95 21.1 22.0 26.0 640

20p 0.5 0.95 22.1 23.0 27.0 719

24p 0.5 0.95 23.7 24.6 28.8 827

27p 0.5 0.95 24.8 25.7 30.0 894

36p 0.5 0.95 28.0 28.9 33.6 1129

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

IEEE 45

IEEE 1580

MINIMUMBENDINGRADIUS

(mm)

45

49

68

82

88

95

104

108

115

120

134

LR, DNV, ABS, GL, BV, USCG, RAN

Transport Canada Marine Safety

“Cable constructions, Jackets, and Inner

components tested to UL 1309 - CSA C22.2 No. 245

for Cold Bend (-40C) and Cold Impact (-35C)”

Page 47: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 45

RBFLEXIBLE OFFSHORE COLLECTIVE SCREENED BRAIDED/ARMOUREDINSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1t 0.75 1.2 8.7 9.6 12.3 178 3t 0.75 1.2 13.0 13.9 17.1 315 4t 0.75 1.2 14.4 15.3 18.5 372 7t 0.75 1.2 17.4 18.3 21.8 530 1t 1.5 1.5 9.6 10.5 13.2 217 3t 1.5 1.5 14.8 15.7 19.0 415 4t 1.5 1.5 16.2 17.1 20.6 500 7t 1.5 1.5 19.7 20.6 24.3 734

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1p 0.75 1.2 8.3 9.2 11.9 166 2p 0.75(quad form) 1.2 9.2 10.1 12.8 195 4p 0.75 1.2 14.1 15.0 18.2 325 8p 0.75 1.2 17.8 18.7 22.2 483

10p 0.75 1.2 19.2 20.1 23.8 560 12p 0.75 1.2 21.0 21.9 25.9 650 16p 0.75 1.2 23.0 23.9 28.1 78420p 0.75 1.2 24.3 25.2 29.5 899 24p 0.75 1.2 25.8 26.7 31.2 1027 27p 0.75 1.2 27.3 28.2 32.7 1126 36p 0.75 1.2 30.8 31.7 36.7 1427 1p 1.0 1.3 8.7 9.4 12.1 177 2p 1.0(quad form) 1.3 9.7 10.4 13.1 210 4p 1.0 1.3 15.0 15.4 18.7 350 8p 1.0 1.3 19.0 19.3 23.0 539

10p 1.0 1.3 20.7 20.7 24.5 615 12p 1.0 1.3 22.4 22.6 26.6 715 16p 1.0 1.3 24.8 24.9 29.1 877 20p 1.0 1.3 25.9 26.0 30.3 1000 24p 1.0 1.3 27.8 27.8 32.3 115727p 1.0 1.3 29.2 29.1 33.9 1274 36p 1.0 1.3 32.9 32.8 37.8 1602 1p 1.5 1.5 9.1 10.0 12.7 198 2p 1.5(quad form) 1.5 10.4 11.3 14.2 254 4p 1.5 1.5 15.8 16.7 20.1 421 8p 1.5 1.5 20.3 21.2 25.0 660

10p 1.5 1.5 21.9 22.8 26.8 772 12p 1.5 1.5 24.0 24.9 29.1 900 16p 1.5 1.5 26.3 27.2 31.7 1102 20p 1.5 1.5 27.8 28.7 33.2 1281 24p 1.5 1.5 29.5 30.4 35.2 1475 27p 1.5 1.5 31.2 32.1 37.1 1651 36p 1.5 1.5 35.2 36.1 41.4 2077 1p 2.5 2.1 10.5 11.4 14.4 255 2p 2.5(quad form) 2.1 11.8 12.7 15.7 321 4p 2.5 2.1 18.5 19.4 23.1 563 8p 2.5 2.1 23.9 24.8 29.1 919

10p 2.5 2.1 25.9 26.8 31.4 1081 12p 2.5 2.1 28.3 29.2 33.9 1263 16p 2.5 2.1 31.3 32.2 37.2 1681 20p 2.5 2.1 32.8 33.7 38.8 1829 24p 2.5 2.1 35.2 36.1 41.3 2130 27p 2.5 2.1 37.1 38.0 43.6 2370 36p 2.5 2.1 41.9 42.8 48.9 3040

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

MINIMUMBENDINGRADIUS

(mm)

4851738995

1041131181251311474852759298

106116121129135151515781

100107116127133141148166576393

116125136149155165174195

MINIMUMBENDINGRADIUS

(mm)

4969748753768297

Page 48: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 146

FZ

CONSTRUCTIONConductor: Finely stranded tinned annealedcopper to IEC 60228 Class 5&6 & AS/NZS 1125.

Insulation: LSFLEX®R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant Low Smoke, Zero Halogen (HF-90 to IEC 60092-351) Splash resistant to oil, skydrol, petrol, acid, sea water. Resists ozone and UV.

Separator: Polypropylene Tape

Screen: Individual and CollectiveAluminium/Laminate Tape

Drain Wire: Tinned annealed copper

Separator: Polypropylene Tape

Ripcord: High strength ripcord under bedding

Bedding: LSFLEX®F-10 Low Smoke, Zero Halogen (pressure extruded)

Braid/Armour Options:Galvanized Steel Wire Braid (90%)Tinned Copper Wire Braid (90%)(Also available with drain wire under the braid)

Ripcord: High strength ripcord under jacket

Jacket: LSFLEX®S-50, Polyolefinic, Flame Retardant, Low Smoke, Zero Halogen (SHF-1 to IEC 60092-359) Splash resistant tooil, skydrol, petrol, acid, sea water. Resists ozone and UV. SHF-2 also available.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING250 Volts

CORE COLOURSTo customer specification

JACKET COLOURTo customer specification

STANDARDS

APPROVALS

APPLICATIONFlexible Instrumentation cables suitable for all offshore applications, where mechanical orEMC protection is required.

AS/NZS 1125AS/NZS 1660.5.1AS/NZS 1660.5.2AS/NZS 1660.5.3AS/NZS 1660.5.6

IEC 60228IEC 60092-350 IEC 60092-376IEC 60332-1 IEC 60332-3-22 IEC 60754-1&2 IEC 61034-1&2

NEK 606

FLEXIBLE OFFSHORE INDIVIDUAL & COLLECTIVE SCREENED BRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1p 0.5 0.95 7.8 8.7 11.2 164

2p 0.5 0.95 12.0 12.9 15.9 273

4p 0.5 0.95 14.3 15.2 18.4 321

8p 0.5 0.95 18.1 19.0 22.7 476

10p 0.5 0.95 19.6 20.5 24.2 558

12p 0.5 0.95 21.4 22.3 26.2 647

16p 0.5 0.95 23.6 24.5 28.8 813

20p 0.5 0.95 24.7 25.6 29.9 929

24p 0.5 0.95 26.3 27.2 31.7 1043

27p 0.5 0.95 27.8 28.7 33.2 1133

36p 0.5 0.95 31.3 32.2 37.2 1388

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

IEEE 45

IEEE 1580

MINIMUMBENDINGRADIUS

(mm)

45

64

74

91

97

105

115

119

127

133

149

LR, DNV, ABS, GL, BV, USCG, RAN

Transport Canada Marine Safety

“Cable constructions, Jackets, and Inner

components tested to UL 1309 - CSA C22.2 No. 245

for Cold Bend (-40C) and Cold Impact (-35C)”

Page 49: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 47

FZFLEXIBLE OFFSHORE INDIVIDUAL & COLLECTIVE SCREENED BRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1t 0.75 1.2 9.4 9.6 12.3 179 3t 0.75 1.2 15.7 15.3 18.5 351 4t 0.75 1.2 17.4 16.6 20.0 417 7t 0.75 1.2 21.0 19.9 23.6 603 1t 1.5 1.5 10.1 10.5 13.2 233 3t 1.5 1.5 17.0 16.9 20.3 496 4t 1.5 1.5 18.8 18.6 22.1 605 7t 1.5 1.5 22.7 22.3 26.3 890

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1p 0.75 1.2 8.3 9.2 11.9 167 2p 0.75 1.2 12.9 13.8 17.0 311 4p 0.75 1.2 15.4 16.3 19.7 370 8p 0.75 1.2 19.5 20.4 24.2 566

10p 0.75 1.2 21.3 22.2 26.2 649 12p 0.75 1.2 23.1 24.0 28.2 805 16p 0.75 1.2 25.5 26.4 30.9 960 20p 0.75 1.2 26.9 27.8 32.3 1087 24p 0.75 1.2 28.6 29.5 34.3 1230 27p 0.75 1.2 30.3 31.2 35.9 1384 36p 0.75 1.2 34.2 35.1 40.3 1692 1p 1.0 1.3 8.5 9.4 12.1 178 2p 1.0 1.3 13.2 14.1 17.3 337 4p 1.0 1.3 15.5 16.4 19.8 401 8p 1.0 1.3 20.3 21.2 25.0 633

10p 1.0 1.3 21.9 22.8 26.8 746 12p 1.0 1.3 24.0 24.9 29.1 897 16p 1.0 1.3 26.3 27.2 31.7 108020p 1.0 1.3 27.8 28.7 33.2 1241 24p 1.0 1.3 29.5 30.4 35.2 1422 27p 1.0 1.3 31.2 32.1 37.1 1548 36p 1.0 1.3 35.2 36.1 41.4 1972 1p 1.5 1.5 9.1 10.0 12.7 212 2p 1.5 1.5 14.4 15.3 18.6 435 4p 1.5 1.5 17.3 18.2 21.6 515 8p 1.5 1.5 22.0 22.9 26.9 818

10p 1.5 1.5 24.0 24.9 29.2 1004 12p 1.5 1.5 26.0 26.9 31.4 115716p 1.5 1.5 28.8 29.7 34.5 1386 20p 1.5 1.5 30.4 31.3 36.3 1634 24p 1.5 1.5 32.3 33.2 38.3 1873 27p 1.5 1.5 34.2 35.1 40.3 2080 36p 1.5 1.5 38.6 39.5 45.2 2658 1p 2.5 2.1 10.5 11.4 14.4 269 2p 2.5 2.1 16.5 17.4 20.8 561 4p 2.5 2.1 19.8 20.7 24.4 661 8p 2.5 2.1 25.6 26.5 31.0 1115

10p 2.5 2.1 28.0 28.9 33.6 1306 12p 2.5 2.1 30.6 31.5 36.5 1522 16p 2.5 2.1 33.8 34.7 40.0 1903 20p 2.5 2.1 35.5 36.4 41.9 2242 24p 2.5 2.1 38.0 38.9 44.6 2612 27p 2.5 2.1 39.9 40.8 46.6 2874 36p 2.5 2.1 45.3 46.2 52.5 3723

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

MINIMUMBENDINGRADIUS

(mm)

48687997

105113124129137144161486979

100107116127133141148166517487

108117126138145153161181578398

124134146160167178186210

MINIMUMBENDINGRADIUS

(mm)

49748094538188

105

Page 50: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 148

HT

CONSTRUCTIONConductor: Finely stranded annealed copperto IEC 60228 Class 5&6 & AS/NZS 1125.Available in plain or tinned.

Flame Barrier: Fire Resistant, Halogen Free, Glass Mica Tape

Insulation: LSFLEX®R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant, Low Smoke, Zero Halogen (HF-90 to IEC 60092-351) Splash resistant to oil, skydrol, petrol, acid, sea water. Resists ozone and UV.

Ripcord: High strength ripcord under bedding

Bedding: LSFLEX®F-10 Low Smoke, Zero Halogen (pressure extruded)

Braid/Armour Options:Galvanized Steel Wire Braid (90%)Tinned Copper Wire Braid (90%) (Also available with drain wire under the braid)

Ripcord: High strength ripcord under jacketin multicores

Jacket: LSFLEX®S-50, Polyolefinic, Flame Retardant, Low Smoke, Zero Halogen (SHF-1 to IEC 60092-359) Splash resistant tooil, skydrol, petrol, acid, sea water. Resists ozone and UV. SHF-2 also available.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING600/1000 Volts

CORE COLOURSTo customer specification

JACKET COLOURTo customer specification

STANDARDS

APPROVALS

APPLICATIONFlexible Power and Control cables suitable for all offshore applications, where circuit integrityis required under fire conditions and mechanical or EMC protection is also required.

AS/NZS 1125AS/NZS 1660.5.1AS/NZS 1660.5.2AS/NZS 1660.5.3AS/NZS 1660.5.6

IEC 60228IEC 60092-350 IEC 60092-353IEC 60331-1IEC 60331-21IEC 60332-1 IEC 60332-3-22 IEC 60754-1&2 IEC 61034-1&2

NEK 606

FLEXIBLE OFFSHORE FIRE RESISTANTBRAIDED/ARMOURED POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF MINIMUM NOMINAL NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING OD OVER OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS BEDDING BRAID (mm) (kg/km) (Amps)

AREA (mm2) (mm) (mm) (mm) NOMINAL

1c 10 60 8.4 9.3 12.0 241 72

1c 16 66 9.5 10.4 13.1 311 96

1c 25 76 11.3 12.2 15.2 435 127

1c 35 83 12.7 13.6 16.6 561 157

1c 50 93 14.5 15.4 18.6 739 196

1c 70 103 16.3 17.2 20.7 955 242

1c 95 116 18.5 19.4 23.1 1242 293

1c 120 127 20.6 21.5 25.5 1514 339

1c 150 139 22.8 23.7 27.7 1859 389

1c 185 152 25.1 26.0 30.3 2226 444

1c 240 166 27.8 28.7 33.3 2684 522

1c 300 182 30.5 31.4 36.3 3419 601

1c 400 204 34.6 35.5 40.7 4397 670

1c 500 225 38.4 39.3 45.0 5484 720

1c 630 248 42.6 43.5 49.5 6789 780

*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

IEEE 45

IEEE 1580

CONDUCTORDIAMETER

(mm)

4.1

5.1

6.4

7.8

9.2

10.8

12.8

14.5

16.3

18.0

20.3

22.5

26.0

29.2

32.8

APPROX. NUMBEROF WIRES

TRIANGLE CLASS 5 CLASS 6

144 80 320

224 128 512

350 200 800

490 280 1120

707 400 705

991 356 990

1344 485 1340

1692 614 1690

2124 765 2123

2584 994 1470

3344 1125 1905

4144 1530 2385

5488 2035 3200

6944 1768 4010

8736 3200 5020

LR, DNV, ABS, GL, BV, USCG,

Transport Canada Marine Safety

“Cable constructions, Jackets, and Inner

components tested to UL 1309 - CSA C22.2 No. 245

for Cold Bend (-40C) and Cold Impact (-35C)”

Page 51: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 49

HTFLEXIBLE OFFSHORE FIRE RESISTANTBRAIDED/ARMOURED POWER & CONTROL0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF MINIMUM NOMINAL NOMINAL OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING OD OVER OD OVER DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS BEDDING BRAID (mm) (kg/km) (Amps)

AREA (mm2) (mm) (mm) (mm) NOMINAL2c 1.5 65 9.4 10.3 13.0 209 202c 2.5 74 10.9 11.8 14.7 270 262c 4 78 11.7 12.6 15.5 317 342c 6 85 12.9 13.8 17.0 392 442c 10 96 15.1 16.0 19.2 530 612c 16 109 17.4 18.3 21.8 711 822c 25 128 20.7 21.6 25.6 1009 1082c 35 144 23.6 24.5 28.7 1305 1333c 1.5 68 9.9 10.8 13.5 237 163c 2.5 77 11.5 12.4 15.4 311 213c 4 81 12.4 13.3 16.2 373 283c 6 90 13.9 14.8 18.0 474 363c 10 102 16.0 16.9 20.4 657 503c 16 116 18.5 19,4 23.1 893 673c 25 135 22.1 23.0 26.9 1269 893c 35 151 25.1 26.0 30.3 1657 1103c 50 171 28.6 29.5 34.3 2251 1373c 70 193 32.6 33.5 39.2 2943 1693c 95 218 37.2 38.1 43.7 3876 2053c 120 242 41.5 42.4 48.4 4758 2373c 150 269 46.3 47.2 53.8 5943 2723c 185 296 51.2 52.1 59.1 7165 3113c 240 327 56.8 57.7 65.3 8695 3654c 1.5 74 11.0 11.9 14.9 286 164c 2.5 82 12.6 13.5 16.4 363 214c 4 89 13.7 14.6 17.8 455 284c 6 97 15.2 16.1 19.3 566 364c 10 111 17.8 18.7 22.2 802 504c 16 127 20.3 21.4 25.4 1110 674c 25 148 24.5 25.4 29.4 1587 894c 35 168 27.9 28.8 33.6 2094 1104c 50 189 31.8 32.7 37.7 2837 1374c 70 213 36.3 37.2 42.7 3740 1694c 95 242 41.4 42.3 48.3 4931 2054c 120 268 46.1 47.0 53.5 6054 2374c 150 298 51.7 52.6 59.7 7588 2724c 185 328 57.1 58.0 65.6 9144 3115c 1.5 80 12.1 13.0 16.0 328 165c 2.5 91 14.1 15.0 18.2 434 215c 4 96 15.1 16.0 19.3 530 285c 6 107 17.0 17.9 21.3 681 365c 10 121 19.7 20.6 24.3 961 505c 16 138 22.8 23.7 27.7 1323 675c 25 164 27.4 28.3 32.8 1928 895c 35 186 31.2 32.1 37.1 2557 1105c 50 210 35.6 36.5 42.0 3479 1375c 70 239 40.8 41.7 47.7 4603 1695c 95 269 46.3 47.2 53.8 6051 2055c 120 299 51.8 52.7 59.8 7447 2375c 150 334 58.1 59.0 66.8 9360 2725c 185 367 64.1 65.0 73.3 11271 3115c 240 406 71.1 72.0 81.1 13702 3657c 1.5 86 13.2 14.1 17.3 387 12

10c 1.5 107 17.0 17.9 21.4 539 1112c 1.5 111 17.7 18.6 22.1 601 1014c 1.5 116 18.6 19.5 23.2 676 1016c 1.5 122 19.7 20.6 24.4 745 919c 1.5 129 21.0 21.9 25.9 859 921c 1.5 136 22.3 23.2 27.2 931 924c 1.5 149 24.6 25.5 29.8 1068 927c 1.5 154 25.4 26.3 30.7 1170 933c 1.5 165 27.5 28.4 33.0 1370 937c 1.5 171 28.6 29.5 34.3 1506 97c 2.5 97 15.3 16.2 19.5 508 21

10c 2.5 121 19.6 20.5 24.2 712 2012c 2.5 127 20.6 21.5 25.5 821 1814c 2.5 133 21.7 22.6 26.6 914 1816c 2.5 140 23.0 23.9 28.1 1023 1619c 2.5 148 24.5 25.4 29.6 1168 1521c 2.5 157 25.9 26.8 31.3 1284 1524c 2.5 172 28.7 29.6 34.3 1471 1527c 2.5 176 29.6 30.5 35.2 1616 1533c 2.5 190 32.1 33.0 38.0 1898 1537c 2.5 199 33.6 34.5 39.7 2104 15

*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

CONDUCTORDIAMETER

(mm)

1.52.12.53.14.15.16.47.81.52.12.53.14.15.16.47.89.2

10.812.814.516.318.020.31.52.12.53.14.15.16.47.89.2

10.812.814.516.318.01.52.12.53.14.15.16.47.89.2

10.812.814.516.318.020.31.51.51.51.51.51.51.51.51.51.51.52.12.12.12.12.12.12.12.12.12.12.1

APPROX. NUMBEROF WIRES

TRIANGLE CLASS 5 CLASS 6

- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120

- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990

1344 485 13401692 614 16902124 765 21232584 994 14703344 1125 1905

- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990

1344 485 13401692 614 16902124 765 21232584 994 1470

- - -- - -- - -

84 84 192144 80 320224 128 512350 200 800490 280 1120 707 400 705991 356 990

1344 485 13401692 614 16902124 765 21232584 994 14703344 1125 1905

- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -- - -

Page 52: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 150

FK

CONSTRUCTIONConductor: Finely stranded tinned annealedcopper to IEC 60228 Class 5&6 & AS/NZS 1125.

Flame Barrier: Fire Resistant, Halogen Free, Glass Mica Tape

Insulation: LSFLEX®R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant Low Smoke, Zero Halogen (HF-90 to IEC 60092-351) Splash resistant to oil, skydrol, petrol, acid, sea water. Resists ozone and UV.

Separator: Polypropylene Tape

Screen: Aluminium/Laminate Tape

Drain Wire: Tinned annealed copper

Ripcord: High strength ripcord under bedding

Bedding: LSFLEX®F-10 Low Smoke, Zero Halogen (pressure extruded)

Braid/Armour Options:Galvanized Steel Wire Braid (90%)Tinned Copper Wire Braid (90%) (Also available with drain wire under the braid)

Ripcord: High strength ripcord under jacket

Jacket: LSFLEX®S-50, Polyolefinic, Flame Retardant, Low Smoke, Zero Halogen (SHF-1 to IEC 60092-359) Splash resistant tooil, skydrol, petrol, acid, sea water. Resists ozone and UV. SHF-2 also available.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING250 Volts

CORE COLOURSTo customer specification

JACKET COLOURTo customer specification

STANDARDS

APPROVALS

APPLICATIONFlexible Instrumentation cables suitable for all offshore applications, where circuit integrity isrequired under fire conditions and mechanical or EMC protection is also required.

AS/NZS 1125

AS/NZS 1660.5.1

AS/NZS 1660.5.2

AS/NZS 1660.5.3

AS/NZS 1660.5.6

IEC 60228

IEC 60092-350

IEC 60092-376

IEC 60331-1

IEC 60331-21

IEC 60332-1

IEC 60332-3-22

IEC 60754-1&2

IEC 61034-1&2

NEK 606

FLEXIBLE OFFSHORE FIRE RESISTANTCOLLECTIVE SCREENED BRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1p 0.5 0.95 9.3 10.2 12.9 189

2p 0.5(quad form) 0.95 10.6 11.5 14.4 236

4p 0.5 0.95 16.1 17.0 20.4 387

8p 0.5 0.95 20.7 21.6 25.6 603

10p 0.5 0.95 22.4 23.3 27.3 686

12p 0.5 0.95 24.4 25.3 29.6 797

16p 0.5 0.95 27.0 27.9 32.4 974

20p 0.5 0.95 28.3 29.2 34.0 1121

24p 0.5 0.95 30.3 31.2 36.0 1277

27p 0.5 0.95 31.8 32.7 37.7 1404

36p 0.5 0.95 35.9 36.8 42.4 1778

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

IEEE 45

IEEE 1580

MINIMUMBENDINGRADIUS

(mm)

64

72

102

128

136

148

162

170

180

189

212

LR, DNV, ABS, GL, BV, USCG,

Transport Canada Marine Safety

“Cable constructions, Jackets, and Inner

components tested to UL 1309 - CSA C22.2 No. 245

for Cold Bend (-40C) and Cold Impact (-35C)”

Page 53: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 51

FKFLEXIBLE OFFSHORE FIRE RESISTANTCOLLECTIVE SCREENED BRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1t 0.75 1.2 10.5 11.4 14.3 236 3t 0.75 1.2 16.1 17.0 20.5 435 4t 0.75 1.2 17.8 18.7 22.2 519 7t 0.75 1.2 21.6 22.5 26.5 766 1t 1.5 1.5 11.2 12.1 15.1 277 3t 1.5 1.5 17.7 18.6 22.1 542 4t 1.5 1.5 19.4 20.3 24.0 657 7t 1.5 1.5 23.8 24.7 28.9 999

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1p 0.75 1.2 9.8 10.7 13.4 206 2p 0.75 (quad form) 1.2 11.2 12.1 15.0 262 4p 0.75 1.2 17.3 18.2 21.7 442 8p 0.75 1.2 22.1 23.0 27.0 690

10p 0.75 1.2 24.1 25.0 29.3 813 12p 0.75 1.2 26.2 27.1 31.6 935 16p 0.75 1.2 28.9 29.8 34.6 1149 20p 0.75 1.2 30.5 31.4 36.4 1343 24p 0.75 1.2 32.5 33.4 38.4 1522 27p 0.75 1.2 34.3 35.2 40.5 1690 36p 0.75 1.2 38.8 39.7 45.4 2148 1p 1.0 1.3 10.2 11.1 13.8 223 2p 1.0 (quad form) 1.3 11.4 12.3 15.3 278 4p 1.0 1.3 17.8 18.7 22.1 471 8p 1.0 1.3 22.7 23.6 27.6 741

10p 1.0 1.3 24.7 25.6 29.9 876 12p 1.0 1.3 27.1 28.0 32.5 1019 16p 1.0 1.3 29.7 30.6 35.4 1244 20p 1.0 1.3 31.4 32.3 37.3 1459 24p 1.0 1.3 33.6 34.5 39.7 1689 27p 1.0 1.3 35.3 36.2 41.4 1843 36p 1.0 1.3 39.8 40.7 46.5 2348 1p 1.5 1.5 10.7 11.6 14.5 250 2p 1.5 (quad form) 1.5 12.0 12.9 15.9 311 4p 1.5 1.5 18.8 19.7 23.4 545 8p 1.5 1.5 24.3 25.2 29.5 882

10p 1.5 1.5 26.3 27.2 31.7 1035 12p 1.5 1.5 28.8 29.7 34.4 1208 16p 1.5 1.5 31.8 32.7 37.8 1498 20p 1.5 1.5 33.6 34.5 39.8 1764 24p 1.5 1.5 35.8 36.7 42.2 2034 27p 1.5 1.5 37.8 38.7 44.2 2241 36p 1.5 1.5 42.7 43.6 49.6 2865 1p 2.5 2.1 12.0 12.9 15.8 303 2p 2.5 (quad form) 2.1 13.8 14.7 17.9 404 4p 2.5 2.1 21.7 22.6 26.6 712 8p 2.5 2.1 281 29.1 33.9 1190

10p 2.5 2.1 30.8 31.7 36.7 1416 12p 2.5 2.1 33.7 34.6 39.8 1653 16p 2.5 2.1 37.2 38.1 43.7 2061 20p 2.5 2.1 39.1 40.0 45.7 2424 24p 2.5 2.1 41.8 42.7 48.8 2822 27p 2.5 2.1 44.2 45.1 51.3 3139 36p 2.5 2.1 49.9 50.8 57.6 4024

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

MINIMUMBENDINGRADIUS

(mm)

6775

1091351461581731821922032276976

1111381491621771861992072337379

1171471591721891992112212487989

133169183199218229244257288

MINIMUMBENDINGRADIUS

(mm)

7110211113375

111120145

Page 54: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 152

FE

CONSTRUCTIONConductor: Finely stranded annealed copperto IEC 60228 Class 5&6 & AS/NZS 1125.Available in plain or tinned.

Flame Barrier: Fire Resistant, Halogen Free, Glass Mica Tape

Insulation: LSFLEX®R-30, Cross-linked,Polyolefinic, Thermoset, Flame Retardant Low Smoke, Zero Halogen (HF-90 to IEC 60092-351) Splash resistant to oil, skydrol, petrol, acid, sea water. Resists ozone and UV.

Separator: Polypropylene Tape

Screen: Individual and CollectiveAluminium/Laminate Tape

Drain Wire: Tinned annealed copper

Separator: Polypropylene Tape

Ripcord: High strength ripcord under bedding

Bedding: LSFLEX®F-10 Low Smoke, Zero Halogen (pressure extruded)

Braid/Armour Options:Galvanized Steel Wire Braid (90%)Tinned Copper Wire Braid (90%) (Also available with drain wire under the braid)

Ripcord: High strength ripcord under jacket

Jacket: LSFLEX®S-50, Polyolefinic, Flame Retardant, Low Smoke, Zero Halogen (SHF-1 to IEC 60092-359) Splash resistant tooil, skydrol, petrol, acid, sea water. Resists ozone and UV. SHF-2 also available.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING250 Volts

CORE COLOURSTo customer specification

JACKET COLOURTo customer specification

STANDARDS

APPROVALS

APPLICATIONFlexible Instrumentation cables suitable for all offshore applications, where circuit integrityis required under fire conditions and mechanical or EMC protection is also required.

AS/NZS 1125

AS/NZS 1660.5.1

AS/NZS 1660.5.2

AS/NZS 1660.5.3

AS/NZS 1660.5.6

IEC 60228

IEC 60092-350

IEC 60092-376

IEC 60331-1

IEC 60331-21

IEC 60332-1

IEC 60332-3-22

IEC 60754-1&2

IEC 61034-1&2

NEK 606

FLEXIBLE OFFSHORE FIRE RESISTANTINDIVIDUAL & COLLECTIVE SCREENEDBRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1p 0.5 0.95 9.3 10.7 12.9 189

2p 0.5 0.95 14.7 15.6 18.8 379

4p 0.5 0.95 17.5 18.4 21.9 449

8p 0.5 0.95 22.4 23.3 27.3 701

10p 0.5 0.95 24.5 25.4 29.6 828

12p 0.5 0.95 26.5 27.4 31.9 951

16p 0.5 0.95 29.4 30.3 35.0 1170

20p 0.5 0.95 31.0 31.9 36.8 1378

24p 0.5 0.95 32.9 33.8 39.1 1567

27p 0.5 0.95 34.8 35.7 41.0 1722

36p 0.5 0.95 39.3 40.2 46.0 2188

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

IEEE 45

IEEE 1580

MINIMUMBENDINGRADIUS

(mm)

64

94

110

137

148

160

175

184

195

205

230

LR, DNV, ABS, GL, BV, USCG,

Transport Canada Marine Safety

“Cable constructions, Jackets, and Inner

components tested to UL 1309 - CSA C22.2 No. 245

for Cold Bend (-40C) and Cold Impact (-35C)”

Page 55: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 53

FEFLEXIBLE OFFSHORE FIRE RESISTANTINDIVIDUAL & COLLECTIVE SCREENEDBRAIDED/ARMOURED INSTRUMENTATION250V 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX TRIADS (t) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1t 0.75 1.2 10.5 11.4 14.3 236 3t 0.75 1.2 17.4 18.4 21.8 487 4t 0.75 1.2 19.1 20.0 23.7 586 7t 0.75 1.2 23.2 24.1 28.3 869 1t 1.5 1.5 11.2 12.1 15.1 277 3t 1.5 1.5 18.8 19.7 23.4 606 4t 1.5 1.5 20.9 21.8 25.7 746 7t 1.5 1.5 25.3 26.2 30.5 1110

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

NUMBER OF CONDUCTOR NOMINAL NOMINAL OVERALL APPROX PAIRS (p) DIAMETER OD OVER OD OVER DIAMETER WEIGHT

X CROSS SECTION (mm) BEDDING BRAID (mm) (kg/km)AREA (mm2) (mm) (mm) NOMINAL

1p 0.75 1.2 9.8 10.7 13.4 206 2p 0.75 1.2 15.5 16.4 19.9 432 4p 0.75 1.2 18.6 19.5 23.2 509 8p 0.75 1.2 24.0 24.9 29.2 813

10p 0.75 1.2 26.0 26.9 31.4 951 12p 0.75 1.2 28.4 29.3 34.1 1106 16p 0.75 1.2 31.4 32.4 37.4 1365 20p 0.75 1.2 33.0 33.9 39.1 1586 24p 0.75 1.2 35.3 36.2 41.5 1818 27p 0.75 1.2 37.3 38.2 43.7 2020 36p 0.75 1.2 42.1 43.0 49.1 2573 1p 1.0 1.3 10.2 11.1 13.8 223 2p 1.0 1.3 15.8 16.7 20.2 461 4p 1.0 1.3 18.7 19.6 23.3 543 8p 1.0 1.3 24.6 25.5 29.8 886

10p 1.0 1.3 26.9 27.8 32.3 1051 12p 1.0 1.3 29.1 30.0 34.8 1212 16p 1.0 1.3 32.3 33.2 38.2 1503 20p 1.0 1.3 34.0 34.9 40.2 1768 24p 1.0 1.3 36.2 37.1 42.6 2038 27p 1.0 1.3 38.2 39.1 44.9 2265 36p 1.0 1.3 43.2 44.1 50.3 2892 1p 1.5 1.5 10.7 11.6 14.5 251 2p 1.5 1.5 16.9 17.8 21.3 523 4p 1.5 1.5 20.3 21.2 24.9 622 8p 1.5 1.5 26.0 26.9 31.4 1022

10p 1.5 1.5 28.4 29.3 34.1 1215 12p 1.5 1.5 31.1 32.0 37.0 1428 16p 1.5 1.5 34.4 35.3 40.6 1765 20p 1.5 1.5 36.0 36.9 42.4 2070 24p 1.5 1.5 38.6 39.5 45.2 2407 27p 1.5 1.5 40.7 41.6 47.6 2677 36p 1.5 1.5 46.0 46.9 53.5 3426 1p 2.5 2.1 12.0 12.9 15.8 304 2p 2.5 2.1 19.1 20.0 23.7 674 4p 2.5 2.1 23.0 23.9 28.1 805 8p 2.5 2.1 30.1 31.0 35.8 1351

10p 2.5 2.1 32.7 33.6 38.6 1599 12p 2.5 2.1 35.7 36.6 42.1 1889 16p 2.5 2.1 38.6 40.5 46.3 2364 20p 2.5 2.1 41.7 42.6 48.6 2805 24p 2.5 2.1 44.6 45.5 51.8 3269 27p 2.5 2.1 47.1 48.0 54.6 363636p 2.5 2.1 53.4 54.3 61.7 4717

Triangle Cables is not liable for any errors, ommisions, etc., and reserves the right to modify specifications at any time

MINIMUMBENDINGRADIUS

(mm)

6799

11614615717018719620821924569

10111714916117419120121322425273

10612515717018520321222623826779

118141179193211231243259273308

MINIMUMBENDINGRADIUS

(mm)

7110911914175

117129152

Page 56: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

UP

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 154

CONSTRUCTIONConductor: Finely stranded annealed copper

to IEC 60228 Class 5&6 & AS/NZS 1125.

Available in plain or tinned.

Insulation: LSFLEX®R-30, Cross-linked,

Polyolefinic, Thermoset, Flame Retardant,

Low Smoke, Zero Halogen (HF-90 to

IEC 60092-351) Splash resistant to oil,

skydrol, petrol, acid, sea water.

Resists ozone and UV.

OPERATING TEMP-40°C to +110°C

VOLTAGE RATING600/1000 Volts

CORE COLOURSTo customer specification

STANDARDS

APPROVALSLR, DNV, ABS, GL, BV, USCG, RAN

APPLICATIONFlexible Single Insulated Power Cables suitable for all shipboard and marine applications

AS/NZS 1125

AS/NZS 1660.5.1

AS/NZS 1660.5.2

AS/NZS 1660.5.3

AS/NZS 1660.5.6

IEC 60228

IEC 60092-350

IEC 60092-353

IEC 60332-1

IEC 60332-3-22

IEC 60754-1&2

IEC 61034-1&2

IEEE 45

IEEE 1580

FLEXIBLE OFFSHORE SWITCHBOARD/PANEL WIRE0.6/1kV 110°C LSZH Oxygen Index >32, HCL Emission <0.5%

NUMBER OF MINIMUM OVERALL APPROX. CURRENT CONDUCTORS (c) BENDING DIAMETER WEIGHT RATING* X CROSS SECTION RADIUS (mm) (kg/km) (Amps)

AREA (mm2) (mm) NOMINAL

1c 0.75 7 2.6 13 16

1c 1.0 7 2.7 15 20

1c 1.5 7 2.9 20 26

1c 2.5 9 3.5 30 32

1c 4 10 3.9 44 43

1c 6 11 4.5 63 52

1c 10 14 5.6 99 72

1c 16 16 6.6 150 96

1c 25 21 8.3 236 127

1c 35 24 9.7 326 157

1c 50 28 11.3 471 196

1c 70 33 13.1 637 242

1c 95 38 15.2 865 293

1c 120 43 17.1 1076 339

1c 150 48 19.3 1370 389

1c 185 54 21.4 1667 444

1c 240 60 23.9 2040 522

1c 300 66 26.4 2654 601

1c 400 76 30.3 3509 690

1c 500 85 33.9 4439 720

1c 630 95 38.0 5585 780

*IEC 60092-352:2005 Table B.4 – Current carrying capacities in continuous service, 90°C operating temperature, 45°C ambient air temperature. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions. Triangle Cables is not liable for any errors, omissions, etc., and reserves the right to modify specifications at any time

CONDUCTORDIAMETER

(mm)

1.2

1.3

1.5

2.1

2.5

3.1

4.1

5.1

6.4

7.8

9.2

10.8

12.8

14.5

16.3

18.0

20.3

22.5

26.0

29.2

32.8

APPROX. NUMBEROF WIRES

TRIANGLE CLASS 5 CLASS 6

- - -

- - -

- - -

- - -

- - -

84 84 192

144 80 320

224 128 512

350 200 800

490 280 1120

707 400 705

991 356 990

1344 485 1340

1692 614 1690

2124 765 2123

2584 994 1470

3344 1125 1905

4144 1530 2385

5488 2035 3200

6944 1768 4010

8736 3200 5020

Page 57: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

TECHNICALINFORMATION

Product Coding 56

Lugging Recommendation 57

Installation Recommendation 58

Conductor Data 59

Current Carrying Capacities/ MUD Fluid Immersion Tests 60

Fire Performance Testing 61

Ripcord Technology 62

Drum Handling Procedures 63

Page 58: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 156

PRODUCT CODING

1. PRODUCT SERIES

eg. (PJ series)

2. JACKET TYPE (Shipboard/Offshore Cables only)

A = SHF-1

C = SHF-2

M = SHF-2 Mud

3. CORE COLOUR CONFIGURATION

eg. SEE COLOUR CODES BELOW

4. BRAID/ARMOUR

A= Aluminum Braid / Overbraid Armor

B= Bronze Braid / Overbraid Armor

E= Polyester + drain wire + Tinned Copper

Wire Braid

F= Tinned Copper Wire Braid + Aluminum

Overbraid Armor

G= Galvanized Steel Wire Braid

K= Bare Copper Wire Braid + drain wire

L= Tinned Copper Wire Braid + drain wire

M= Galvanized Steel Wire Braid + drain wire

P= Plain Copper Wire Braid

R= Aluminum/Polyester + drain wire

S= Steel Wire Armor

T= Tinned Copper Wire Braid

W=Tinned Copper Wire Braid + Bronze Overbraid Armor

X= Not Applicable

5. CONDUCTOR

D= Tinned Annealed Copper Wire

N= Plain Annealed Copper Wire

6. NUMBER OF CONDUCTORS/PAIRS/TRIADS

7. CORE TYPE

C= Power/Control

P= Pair

T= Triad

Q= Quad

8. CONDUCTORCROSS SECTIONAREA (mm2)

9. JACKET COLOUR

OR= Orange

BK= Black

WH= White

GY= Grey

BR= Brown

RE= Red

BL= Blue

GN= Green

EA= Green/Yellow (Earth)

SHIPBOARD /OFFSHORE CABLE - PRODUCT CODES

21 3 4 5 6 7 8 9

PJ C -PA GN/4 C 2.5 BK

COLOUR CODES

Power 1C 2C 3C 4C 5C STANDARD

PF BK BK-WH BK-WH-RE BK-WH-RE-GN BK-WH-RE-OR-GN US (IEEE 45/1580)

PV WH RE-BK BK-WH-RE BK-WH-RE-EA BK-WH-RE-OR-EA US (IEEE 45/1580)

PJ WH BR-BL BR-BL-EA BR-BK-GY-EA BR-BK-GY-BL-EA EUROPE (UK) w/Earth

PA WH RE-BK RE-BK-EA RE-WH-BL-EA RE-WH-BL-BK-EA AUSTRALIA (Fixed)

PD WH BR-BL BR-BL-EA BR-BL-BK-EA BR-WH-BL-BK-EA AUSTRALIA (Flexible)

Control

CG White with Numbers & Words + Green

CA White with Numbers & Words + Earth

CB White with Numbers & Words No Earth or Green

Instrumentation Pairs Triads

DE WH-BK with Numbers & Words WH-BK-RE with Numbers & Words

“1 ONE-1 ONE”, “2 TWO-2 TWO”, etc “1 ONE-1 ONE-1 ONE”, “2 TWO-2 TWO-2 TWO”, etc

Single Pair and Single Triad Wires are not printed.

Page 59: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 57

LUGGING RECOMMENDATION

Cut at required length and remove.

Cut section and slide towards the end ofthe conductor* (allow 5mm clearance)

Place standard lug at the end of conductor

Gently push both lug and section until theymeet the jacket. Cut and remove section.

Compress lug using hexagonal die and

hydraulic crimper

*Stripping at 25mm maximum lengths is recommended. For longerlengths cutting and stripping in 25mm sections is advised.

1

2

3

4

5

Page 60: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 158

INSTALLATION RECOMMENDATION

CORRECTION FACTORS FOR CABLE CURRENT RATING

Bunching of cable

Where more than six cables are bunched together and

operating at their maximum capacity, a correction factor of 0.85

should be applied (assuming insufficient free air circulation).

Single core cables are exempted from this requirement

Ambient temperature

The maximum current ratings in this catalogue are based on an

ambient temperature of 45°C. For other ambient temperatures,

the correction factors shown below should be applied.

* Shorepower cable only

INSTALLATION

Cable runs should be fixed in straight lines as far as

practicable. The minimum bending radius for cable should be

selected in accordance with the table below.

The installation of cables across expansion joints in any

structure should be avoided. Where this is not feasible,

a loop of cable sufficient to accommodate the expansion of

the joint should be provided. The internal radius of the loop is

to be at least 12 times the overall diameter of the cable.

Cables should be installed away from heat sources as far as

practicable. If this cannot be avoided and there is possibility

of damage to the cable, then suitable shields, insulation or

other protective measures should be installed.

Cables are not to be coated or painted with materials

which may adversely affect their jacket or fire performance.

Cables should be installed away from sources of mechanical

damage, as far as is practicable. If this cannot be avoided the

cables should be protected with suitable metallic casing.

VOLTAGE DROP

When selecting cable size, consideration must be given tovoltage drop. Refer to formula and table below:

Vd = L x I mV/Am1000

Where: Vd = voltage drop in volts

L = route length of cable in meters

I = current to be carried in amps

mV/Am = millivolts per ampere metre value

(the drop in voltage shall not exceed 5% of supply voltage)

CONDUCTOR SIZE - SHORT CIRCUIT RATING

The short circuit current ratings in this catalogue are based ona one second duration. To calculate the maximum permissibleshort circuit ratings, the following formula should be applied.

C x 146

t

C = cross section area of conductor in mm2

t = short circuit time in seconds

MAXIMUM INSTALLATION TENSION

To calculate the maximum allowable tension of cables duringinstallation the following formula should be applied:

50 x C x Nc

C = cross section area of conductor in mm2

Nc = total number of cores

Maximum tension must not exceed 20,000N (kg = N/9.81)

* All information above is intended as a guide only

Unbraided all sizes 4X

Unbraided, fire resistant all sizes 8X

Braided all sizes 6X

Braided, fire resistant all sizes 10X

Nylon protected all sizes 15X

Cable Cable MinimumConstruction OD bending radius

(times cable OD)

35°C 40°C 45°C 50°C 55°C 60°C 65°C

90 1.10 1.05 1.00 0.94 0.88 0.82 0.74

110* 1.04 1.00 0.96 0.93 0.89 0.85 0.81

Maximum conductor

temperature

°°CC

Ambient air temperature

0.5 - 65 - -0.75 - 99 - -

1 - 132 - 49.71.5 215 198 30.0 31.92.5 358 330 16.4 17.44 572 528 10.2 10.86 858 792 6.81 7.2310 1430 1320 4.05 4.30

16 2288 2112 2.55 2.7125 3575 3300 1.62 1.7235 25005 4620 1.17 1.2550 7150 6600 0.872 0.92970 10010 9240 0.615 0.65795 13585 12540 0.457 0.491120 17150 15840 0.373 0.403150 21450 19800 0.316 0.344185 26455 24420 0.269 0.296240 34320 31680 0.227 0.252300 42900 39600 0.202 0.227400 57200 52800 0.183 0.208500 75100 66000 0.170 0.195630 90090 83160 0.159 0.184

Cross Short Circuit Voltage DropSectional Current at 50Hz

Area (Amps for (mV/Am)(mm2) 1 second)

90°C 110°C 90°C 110°C

Page 61: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 59

CONDUCTOR DATA

CONVERSION TABLE - CROSS-SECTIONAL AREA

AWG/MCM TO MM2

AWG mm2

20 0.51918 0.82316 1.3114 2.0812 3.3110 5.268 8.376 13.304 21.152 33.621 42.41

1/0 53.492/0 67.433/0 85.014/0 107.2

MCM mm2

250 126.7300 152.0350 177.3400 202.7450 228.0500 253.4550 278.7600 304.0650 329.4700 354.7750 380.0800 405.4850 430.7900 456.0950 481.4

1000 506.71250 633.41500 760.01750 886.72000 1013.4

CONDUCTOR - CONSTRUCTION

Triangle uses very fine 0.3mm copper wires to ensure maximum

flexibility and ease of use. The following table from IEC 60228

provides a comparative analysis.

size (mm2) Triangle class 2 class 5 class 6

0.5 7 X 0.30 7 X 0.30 16 X 0.20 28 X 0.150.75 12 X 0.30 7 X 0.37 24 X 0.20 42 X 0.15

1 14 X 0.30 7 X 0.43 32 X 0.20 56 X 0.151.5 21 X 0.30 7 X 0.52 30 X 0.25 84 X 0.152.5 35 X 0.30 19 X 0.41 50 X 0.25 140 X 0.154 56 X 0.30 19 X 0.52 56 X 0.30 224 X 0.156 84 X 0.30 19 X 0.64 84 X 0.30 192 X 0.2010 144 X 0.30 49 X 0.51 80 X 0.40 320 X 0.2016 224 X 0.30 49 X 0.65 128 X 0.40 512 X 0.2025 350 X 0.30 84 X 0.62 200 X 0.40 800 X 0.2035 490 X 0.30 133 X 0.58 280 X 0.40 1120 X 0.20

50 707 X 0.30 133 X 0.69 400 X 0.40 705 X 0.3070 980 X 0.30 189 X 0.69 356 X 0.50 999 X 0.3095 1344 X 0.30 259 X 0.69 485 X 0.50 1340 X 0.30120 1672 X 0.30 336 X 0.67 614 X 0.50 1699 X 0.30150 2090 X 0.30 592 X 0.69 765 X 0.50 2123 X 0.40185 2584 X 0.30 494 X 0.69 994 X 0.50 1470 X 0.40240 3344 X 0.30 627 X 0.70 1125 X 0.50 1905 X 0.40300 4144 X 0.30 61 X 2.50 1530 X 0.50 2385 X 0.40400 5488 X 0.30 61 X 2.89 2035 X 0.50 3200 X 0.40500 6944X 0.30 61 X 3.20 1768 X 0.50 4010 X 0.40630 8736 X 0.30 59 X 3.70 3200 X 0.50 5020 X 0.40

CONDUCTOR - DC RESISTANCE

To calculate the DC Resistance of copper conductors for a given

temperature (°C), the resistance at 20°C, as detailed must be

multiplied by the appropriate correction factor below.

AMBIENT CorrectionTemperature Factor(°C)

20 1.00025 1.02030 1.03935 1.05940 1.07945 1.09850 1.11855 1.13860 1.15765 1.17770 1.19675 1.21680 1.23685 1.25590 1.275

OVERALL DIAMETER OF CABLEEXCEEDING NOT EXCEEDING

(mm) (mm)

NON-ARMOUREDCABLES

(mm)

ARMOUREDCABLES

(mm)

- 8 200 2506 13 250 30013 20 300 35020 30 350 40030 - 400 450

normal Maximum resistance ofcross- conductor at 20°CsectionalArea plain copper Tinned Copper(mm2) Ohm/Km Ohm/Km

0.5 39.0 40.10.75 26.0 26.7

1 19.5 20.01.5 13.3 13.72.5 7.98 8.214 4.95 5.096 3.30 3.3910 1.91 1.9516 1.21 1.2425 0.780 0.79535 0.554 0.56550 0.386 0.39370 0.272 0.27795 0.206 0.210120 0.161 0.164150 0.129 0.132185 0.106 0.108240 0.0801 0.0817300 0.0641 0.0654400 0.0486 0.0495500 0.0384 0.0391630 0.0287 0.0292

SECURING OF CABLES

Cables should be effectively supported and secured

using flame retardant clips, saddles or straps. Special

care should be taken to avoid any damage caused by

excessive tensioning during installation.

The distance between fixing points should be

selected according to cable type and probability of

vibration, but should not exceed 450mm.

Where cables are installed below cable trays, ladder

or supports, the fixing distance for securing the cable

should be in accordance with the table below.

Page 62: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

CURRENT CARRYING CAPACITIESMUD FLUID IMMERSION TESTS

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 160

MUD Fluid Immersion TestsSpecific grades of our Cable Jackets have been tested by Underwriters Laboratories and meet or exceed theFluid Immersion schedules as listed in NEK-TS-606:2009 – MUD and IEC 600092-350-SHF-2 / MUD Annex G

Page 63: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

FIRE PERFORMANCE TESTING - (IEC 60332-3, AS/NZS 1660.5.1) (IEC 60331, AS/NZS 1660.5.5)

(IEC 60754-1&2, AS/NZS 1660.5.3) (IEC 60134-1&2, AS/NZS 1660.5.2)

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 61

Page 64: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

TRIANGLE CABLES INTRODUCES RIPCORD TECHNOLOGY

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 162

STEP 1 STEP 2

STEP 3 STEP 4

Page 65: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

RECOMMENDED CABLE DRUM HANDLING PROCEDURES

I S S U E 9 . 1 T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S 63

Page 66: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

T R I A N G L E F L E X I B L E L S Z H S H I P B O A R D / O F F S H O R E C A B L E S I S S U E 9 . 164

Triangle Flexible400mm2 Cablebending radius

(actual size)

Bending Radius is the Only truemeasure for cable flexibility.

Triangle manufactures the most flexible cableswith the smallest bending radius!

104mm

Page 67: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1
Page 68: Triangle Flexible LSZH Shipboard/Offshore Cables issue 9obmgnew.weebly.com/uploads/1/1/4/1/11412142/marine_cat_9.1.pdf · triangle flexible lszh shipboard/offshore cables issue 8.0.1

Marine Catalogue issue 9.1

Manufacturing FacilitiesMelbourne, AUSTRALIANakorn Ratchasima, THAILANDWorcester, MA USA

Sales/Distribution Offices

AUSTRALIA

AdelaideBrisbaneHobartMelbournePerthSydneyTownsville

MALAYSIA

Kuala Lumpur

NEW ZEALAND

AucklandChristchurchWellington

THAILAND

BangkokNakorn Ratchasima

USA

HoustonSeattleWorcester

Superior Cable Solutions www.tricab.com