tssr
DESCRIPTION
telecomTRANSCRIPT
document.xlsx
Technical Site Survey ReportFor Collocation Site
Project: Mobitel Stage-VII
Region ZTE Ericsson Huawei
Site ID:
Site Name:
ZTE Engineer:
Sub Contractor name:
Sub Contractor Engineer:
Survey Date:
(V1.05-20101216)
document.xlsx
Technical Site Survey ReportFor Collocation Site
(V1.05-20101216)
1. Current Information
Site Type 2G 900 2G 1800 3G
1.1 Site Basic Information
Survey Item Survey Contents
Site address:
Coordinates Latitude: Longitude: Altitude:
Owner : Operator:
Telephone: Mobile phone:
Name
Telephone:
Equipment room location Equipment installation cabinet:
Roof top Shelter
Greenfield Building
Outdoor Cabinet
Other
Flat land Rocky land
Hand Carry to Rooftops Floors No.
Is there any evidence of flooding near the site? Ie water stained,wall. Yes
Any Special Delivery System Required? Crane Boomtruck
The Distance to the Site from Colombo < 50km 50<D<150km
Access Restriction Yes No Please specify:
Access on 7 Day Yes No If No,Please specify:
Twenty-four hours Yes No If No,Please specify:
Prior appointment for access ( person to be informed before site access )
No Yes Telephone:
Contact person:
Site access key Mobitel Access Key No Landlord Key Other Access Key
Parking space available Yes No
Equipment delivery to its position by Hand Lift Crane
Safe access to all equipment parts & antennas (lifeline systems, fall arrest systems, anchors.)
Yes No
If NO, please specify missing items:
Remarks
Some information is unusual,please remark here:
Site locatin information
Site Owner Information
Mobitel regional leader
Site environment checking
Building Floor No(Excluding Ground Floor):
Distance of Manual Transport required, (Flat land, Rocky land, or Hill), if the distance is >50m
Site access information
Other(mention in remarks)
1.2 Site Existing InformationMeter Cubical Meter Cubical installed Yes NO
SPD Is Meter To ACPDB length > 20m? YES
Power supply
AC DC
Voltage: V Voltage: V
Armod cable length from MC to ACPDB Spare breaker Qty:
Armod cable dimension Breaker/Per capacity:
Additional space for ZTE ACPDB: Rectifier Qty.
Spare Total Breaker Qty:
Spare Total Breaker capacity: Rectifier 1Type out Put Amperage:
Additional breaker Qty: Rectifier 2 Type out Put Amperage:
Additional Breaker capacity: Battery Type and capacity:
Spare AC outlet Qty for test equipment: Battery Type and capacity:
Three phase Single phase
If more than 1 BTS present, Are the AC power cable laid in the same path? Yes
If No, please specify the power cable length in path 2:
ECB
Avaible ECB Qty (Outdoor): Available ECB Qty (Indoor):
Spare ECB holesQty(Outdoor): Spare ECB holes Qty(Indoor):
Required ECB Qty (Outdoor): Required ECB Qty (Indoor):
Gap between available ECBs of the tower:
Tower
Tower Type: Self Support tower (SST) Guyed Mast tower (GMT)
Monopole Tower
Tower Leg Qty 3LEGS 4LEGS Tower Leg type: Anguar Tubular
Tower Height:
Qty of spare antenna poles :
Transmission Equipment type MW Optical transceiver
Remarks
1.3 Existing GSM System information
System 1 Type
GSM 900 BTS Qty DCS 1800
Ericsson 2207 Ericsson 2207
2206 2206
Huawei 3012 Huawei 3012
3012AE 3012AE
3900 3900
3900A 3900A
ZTE 8900 ZTE 8900
8900A 8900A
Rack Qty Rack Qty
Indoor Outdoor Indoor Outdoor
Antenna
Frequency 900MHz 1800MHz 2100MHz
Ant. Type Single Band Dual Band Tri Band
Spare port Type 900MHz 1800MHz 2100MHz
Spare port condition Good Bad With Dust Cap Without Dust Cap
Sector 1 Sector 2 Sector 3
Azimuth (º)
Downtilt (º)E M E M E M Can Ajust the tilt
Elec
Height (m)
Jumper (Ant.) Length (m)
Jumper connector type to Ant Din or N Type
Existing equipment information
`
TMA
IF use TMA Input Yes or No
TMA Qty
Type
Feeder
Type Input 1/2",7/8"or 1 1/4"
connector type Din or N Type
Length (m)
Jumper (BS) Length (m)
System 2 Type
GSM 900 BTS Qty DCS 1800
Ericsson 2207 Ericsson 2207
2206 2206
Huawei 3012 Huawei 3012
3012AE 3012AE
3900 3900
3900A 3900A
ZTE 8900 ZTE 8900
8900A 8900A
Rack Qty Rack Qty
Indoor Outdoor Indoor Outdoor
Antenna
Frequency 900MHz 1800MHz 2100MHz
Ant. Type Single Band Dual Band Tri Band
Spare port QTY 900MHz 1800MHz 2100MHz
Spare port condition Good Bad With Dust Cap Without Dust Cap
Sector 1 Sector 2 Sector 3
Azimuth (º)
Downtilt (º)E M E M E M Can Ajust the tilt
Elec
Height (m)
Jumper (Ant.) Length (m)
Jumper connector type to Ant Din or N Type
TMA
IF use TMA Input Yes or No
TMA Qty
Type
Feeder
Type Input 1/2",7/8"or 1 1/4"
connector type Din or N Type
Length (m)
Jumper (BS) Length (m)
Jumper connector type to BS Input DIN S/R or N type.
Remarks
Existing equipment information
System 3 Type
GSM 900 BTS Qty DCS 1800
Ericsson 2207 Ericsson 2207
2206 2206
Huawei 3012 Huawei 3012
3012AE 3012AE
3900 3900
3900A 3900A
ZTE 8900 ZTE 8900
8900A 8900A
Rack Qty Rack Qty
Indoor Outdoor Indoor Outdoor
Antenna
Frequency 900MHz 1800MHz 2100MHz
Ant. Type Single Band Dual Band Tri Band
Spare port QTY 900MHz 1800MHz 2100MHz
Spare port condition Good Bad With Dust Cap Without Dust Cap
Sector 1 Sector 2 Sector 3
Azimuth (º)
Downtilt (º)E M E M E M Can Ajust the tilt
Elec
Height (m)
Jumper (Ant.) Length (m)
Jumper connector type to Ant Din or N Type
TMA
IF use TMA Input Yes or No
TMA Qty
Type
Feeder
Type Input 1/2",7/8"or 1 1/4"
connector type Din or N Type
Length (m)
Jumper (BS) Length (m)
Jumper connector type to BS Input DIN S/R or N type.
Remarks
System 4Type
GSM 900 BTS Qty DCS 1800
Ericsson 2207 Ericsson 2207
2206 2206
Huawei 3012 Huawei 3012
3012AE 3012AE
3900 3900
3900A 3900A
ZTE 8900 ZTE 8900
8900A 8900A
Rack Qty Rack Qty
Indoor Outdoor Indoor Outdoor
Antenna
Frequency 900MHz 1800MHz 2100MHz
Ant. Type Single Band Dual Band Tri Band
Spare port QTY 900MHz 1800MHz 2100MHz
Spare port condition Good Bad With Dust Cap Without Dust Cap
Sector 1 Sector 2 Sector 3
Azimuth (º)
Existing equipment information
Existing equipment information
Antenna
Downtilt (º)E M E M E M Can Ajust the tilt
Elec
Height (m)
Jumper (Ant.) Length (m)
Jumper connector type to Ant Din or N Type
TMA
IF use TMA Input Yes or No
TMA Qty
Type
Feeder
Type Input 1/2",7/8"or 1 1/4"
connector type Din or N Type
Length (m)
Jumper (BS) Length (m)
Jumper connector type to BS Input DIN S/R or N type.
Remarks
1.4 Existing UMTS 2100 Antenna, Feeder, TMA and RF informationUMTS 2100 BTS Qty
Huawei DBS 3800
DBS 3900
BTS 3900
ZTE 8900 ZTE 8900
8900A 8900A
Rack Qty
Indoor Outdoor Indoor
Antenna
Share with Other System? No Yes If yes,Please specify:
Frequency 900MHz 1800MHz 2100MHz
Ant. Type Single Band Dual Band Tri Band
Spare port QTY 900MHz 1800MHz 2100MHz
Spare port condition Good Bad With Dust Cap Without Dust Cap
Sector 1 Sector 2 Sector 3
Azimuth (º)
Downtilt (º)E M E M E M Can Ajust the tilt
Elec
Height (m)
Jumper (Ant.) Length (m)
Jumper connector type to RRU
Length (m)
Remarks
Existing equipmentinformation
Fiber from RRU to BBU
1.5 Existing MW Information
IDU Information
IDU Qty. Dimension:(No.of U)
Detail description of each unit:
IDU Installed in: 19''Sevice Rack In NodeB/BTS Rack TX Cabinet
DCDB switch for IDU Yes No
E1 connecter type at end point: BNC (L) BNC (S) SMB
Link type SDH PDH
IF cable type 75 Ω 120 Ω
Patch Panel Yes No If Yes,Qty :
MW Antenna
Mounting Type Pole Mounting Wall Mounting Tower Mounting
Ant Qty:
Does Antenna mounting with ODU? Yes No
Remarks
1.6 Other Information not in the above Table
Description of discovered CW-defects or other deficiencies (include photos):
Other Information not in the above Table,such as:
1. Current Information
1.1 Site Basic Information
Survey Contents
Hill
No
4WD
Other Access Key
Other(mention in remarks)
A
Rectifier 1Type out Put Amperage:
Rectifier 2 Type out Put Amperage:
No
Pole
Tower Leg type: Anguar Tubular
BTS Qty
Outdoor
Can Ajust the tilt
Mech
Din or N Type
Input Yes or No
Input 1/2",7/8"or 1 1/4"
Din or N Type
BTS Qty
Outdoor
Can Ajust the tilt
Mech
Din or N Type
Input Yes or No
Input 1/2",7/8"or 1 1/4"
Din or N Type
Input DIN S/R or N type.
BTS Qty
Outdoor
Can Ajust the tilt
Mech
Din or N Type
Input Yes or No
Input 1/2",7/8"or 1 1/4"
Din or N Type
Input DIN S/R or N type.
BTS Qty
Outdoor
Can Ajust the tilt
Mech
Din or N Type
Input Yes or No
Input 1/2",7/8"or 1 1/4"
Din or N Type
Input DIN S/R or N type.
Outdoor
If yes,Please specify:
Can Ajust the tilt
Mech
TX Cabinet
SMZ
Other
2. New ZTE equipment information
Site Type 2G 900 2G 1800 3G
2.1 Site information
Space Checking
Equipment Type Indoor Outdoor
Enough Space for cabinet? Yes No
Need Site acquisition(Just for outdoor sites)? Yes No
Enough vertical cable space? Yes No
Need Extention Bars for Vertical Ladder Yes No
Enough Space for Extention Bars Yes No
Extension Bars (Provide The Drawing) No Yes Qty:
Enough horizontal cable space for fiber & power Yes No
Need extention ladder from tower to cabinet? Yes No
Enough Space for Ant?(Include Sectoral & MW) Yes No
Need additional Ant-mount? No Yes Qty:
Enough space for mount ZTE RRU Yes No
CommentsIn case of "No" for the above requirement,specify solution:
ECBNeed aditional ECBs for Tower No Yes Qty:
CEB supply AC power available? Yes No
AC Phase: 3 Phase 1 Phase
2.2 GSM SolutionGSM System 1
GSM 900 Qty DCS1800 Qty
ZTE BS8900 BC8910 ZTE BS8900 BC8910
PC8910 PC8910
RC8910 RC8910
Ericsson 2207 Ericsson 2207
2206 2206
Huawei 3012 Huawei 3012
3012AE 3012AE
3900 3900
3900A 3900A
Equipment Base Need Additional Steel Frame? No Yes If Yes,Qty:
Antenna and TMA
Can share existing antennas No Yes System Type :Antenna Band New Ant. Ant.type Ant. Height Azimuth Tilt(°)
900MHz Cell1
1800MHz Cell2
2100MHz Cell3
TMA Need TMA? No Yes If Yes,Qty:
Need NSBT? No Yes If Yes,Qty:
Feeder, Jumper etc.
Cell1 Cell 2 Cell 3Jumper Length from Antenna To Feeder/TMA (m)Feeder Length (m)Jumper Length from Feeder/NSBT To BTS (m)If have TMA,Jumper Length from TMA To Feeder (m)
Cable & Pipe
GI Pipe from Meter to BTS
PVC Pipe from the BTS to RRU (fiber & Power)
E1 cable Lenghth: Alarm cable Length:
Remarks
ECB interconnected ground cable Lenghth(35mm2) :
MC To ACDB Power Cable Length (4X16mm2):
BTS Configuration
ACPDB To BTS Power Cable Length (4X6mm2):
SPD Ground Cable Length (25 mm2):
Battety Cabinet Ground Cable Length (25 mm2):
BTS/BBU Ground Cable Length (25mm2):
SPD Pole Ground Cable Length (35 mm2):
GSM System 2
GSM 900 Qty DCS1800 Qty
ZTE BS8900 BC8910 ZTE BS8900 BC8910
PC8910 PC8910
RC8910 RC8910
Ericsson 2207 Ericsson 2207
2206 2206
Huawei 3012 Huawei 3012
3012AE 3012AE
3900 3900
3900A 3900A
Equipment Base Need Additional Steel Frame? No Yes If Yes,Qty:
Antenna and TMA
Can share existing antennas No Yes System Type :Antenna Band New Ant. Ant.type Ant. Height Azimuth Tilt(°)
900MHz Cell1
1800MHz Cell2
2100MHz Cell3
TMA Need TMA? No Yes If Yes,Qty:
Need NSBT? No Yes If Yes,Qty:
Feeder, Jumper etc.
Cell1 Cell 2 Cell 3Jumper Length from Antenna To Feeder/TMA (m)Feeder Length (m)Jumper Length from Feeder/NSBT To BTS (m)If have TMA,Jumper Length from TMA To Feeder (m)
Cable & Pipe
ACPDB To BTS Power Cable Length:
SPD Ground Cable Length:
Battety Cabinet Ground Cable Length:
BTS/BBU Ground Cable Length:
GI Pipe from Meter to BTS
PVC Pipe from the BTS to tower (fiber & Power)
E1 cable Lenghth: Alarm cable Length:
Remarks
GSM System 3
GSM 900 Qty DCS1800 Qty
ZTE BS8900 BC8910 ZTE BS8900 BC8910
PC8910 PC8910
RC8910 RC8910
Ericsson 2207 Ericsson 2207
2206 2206
Huawei 3012 Huawei 3012
3012AE 3012AE
3900 3900
3900A 3900A
Equipment Base Need Additional Steel Frame? No Yes If Yes,Qty:
Antenna and TMA
Can share existing antennas No Yes System Type :Antenna Band New Ant. Ant.type Ant. Height Azimuth Tilt(°)
900MHz Cell1
1800MHz Cell2
2100MHz Cell3
TMA Need TMA? No Yes If Yes,Qty:
Need NSBT? No Yes If Yes,Qty:
Feeder, Jumper etc.
Cell1 Cell 2 Cell 3Jumper Length from Antenna To Feeder/TMA (m)Feeder Length (m)Jumper Length from Feeder/NSBT To BTS (m)If have TMA,Jumper Length from TMA To Feeder (m)
Cable & Pipe
ACPDB To BTS Power Cable Length:
SPD Ground Cable Length:
Battety Cabinet Ground Cable Length:
BTS/BBU Ground Cable Length:
GI Pipe from Meter to BTS
PVC Pipe from the BTS to tower (fiber & Power)
E1 cable Lenghth: Alarm cable Length:
Remarks
BTS Configuration
BTS Configuration
GSM System 4
GSM 900 Qty DCS1800 Qty
ZTE BS8900 BC8910 ZTE BS8900 BC8910
PC8910 PC8910
RC8910 RC8910
Ericsson 2207 Ericsson 2207
2206 2206
Huawei 3012 Huawei 3012
3012AE 3012AE
3900 3900
3900A 3900A
Equipment Base Need Additional Steel Frame? No Yes If Yes,Qty:
Antenna and TMA
Can share existing antennas No Yes System Type :Antenna Band New Ant. Ant.type Ant. Height Azimuth Tilt(°)
900MHz Cell1
1800MHz Cell2
2100MHz Cell3
TMA Need TMA? No Yes If Yes,Qty:
Need NSBT? No Yes If Yes,Qty:
Feeder, Jumper etc.
Cell1 Cell 2 Cell 3Jumper Length from Antenna To Feeder/TMA (m)Feeder Length (m)Jumper Length from Feeder/NSBT To BTS (m)If have TMA,Jumper Length from TMA To Feeder (m)
Cable & Pipe
ACPDB To BTS Power Cable Length:
SPD Ground Cable Length:
Battety Cabinet Ground Cable Length:
BTS/BBU Ground Cable Length:
GI Pipe from Meter to BTS
PVC Pipe from the BTS to tower (fiber & Power)
E1 cable Lenghth: Alarm cable Length:
Remarks
2.3 UMTS SolutionUMTS 2100 Qty UMTS 2100 Qty
ZTE BS8700 BC8910 Huawei DBS 3800
PC8910 DBS 3900
R8880 &OLPB BTS 3900
Equipment Base Need Additional Steel Frame? No Yes If Yes,Qty:
Antenna
Can share existing antennas No Yes System Type :
Antenna Band New Ant. Ant.type Ant. Height Azimuth Tilt(°)
Cell1
2100MHz Cell2
Cell3
GPS
Clearnce
Location of Installation:
Cable Length to BTS
Jumper, Fiber etc.
Cell1 Cell 2 Cell 3
Jumper Length from Antenna To RRU (m)
RRU Power Cable Length from RRU to outdoor LPB (m)
Fiber Length (m)
OLPB Power Cable Length from Rectifier To Outdoor LPB (m)
Cable & Pipe
ACPDB To NODEB Power Cable Length:
SPD Ground Cable Length:
Battery Cabinet Ground Cable Length:
BBU Ground Cable Length:
GI Pipe from Meter to NODEB
PVC Pipe from NODEB to tower (fiber & Power)
E1 cable Lenghth: Alarm cable Length:
Remarks
BTS Configuration
Node BConfiguration
Share with GSM
2.4 ZTE MW SolutionIDU Qty: Dimension (No.ofU):
Space Checking
Need Rectifier for IDU in case of TX Indoor Yes No
Enough space for Rectifier in TX Indoor Yes No
Enough space for TX Rack Outdoor Yes No
Yes No
IF yes mention rack type and Numbere of free U : / , /
Enough space for IF cable of ZTE MW Yes No
Enough space for ZTE MW antenna Yes No
Need new 19" rack for IDU Yes No
Need separate Outdoor TX Rack for IDU Yes No
Distance for E1 cable from BTS/NodeB Outdoor To TX Indoor(m)
Comments In case of "No" for the above requirement,specify solution:
DCDB When ZTE MW IDU,need new DCDB Yes No
E1 Cable Length E1 Cable Qty
Alam Cable Length Alam Cable Qty
Power Cable Length
GI Pipe from TX Inside to BTS/NodeB Outside length
Remarks
Any other information not above and any suspect obstacles for LOS (Line Of Sight) please remark here:
Enough Space for ZTE MW IDU Mount in the existing Rack (for the Capacity of existing MW is not enough)
Cable (for TX Rack inside the cabin)
2. New ZTE equipment information
Tilt(°)
Cell 3
Tilt(°)
Cell 3
Tilt(°)
Cell 3
Tilt(°)
Cell 3
Tilt(°)
Cell 3
TSSR for Swap Site
<本文中的所有信息均为中兴通讯股份有限公司内部信息,未经允许,不得外传> 共 43 页 , 第 14 页
3. Photos ListNO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
18
19
20
21
22
23
26
27
28
29
30
31
TSSR for Swap Site
<本文中的所有信息均为中兴通讯股份有限公司内部信息,未经允许,不得外传> 共 43 页 , 第 15 页
3. Photos ListNecessary photoes must provided: Actual aerial view of sites ( fromTower top)
Panoramic Photo(45Deg per)( Should be over lap)
Equipment Room/Cabinet Outlook(Can be identify the cabin properly)
Location of power source
Close view of Existing antennna Ports (all direction ) (all port should be clearly visible)
Existing Room/Cabinet inside (can have several photos to cover the place)
Existing Equipment detail Inlook (close and inside veiw of the equipment)
Existing Equipment detail Outlook (take with proper distance to fit to the hard copy)
Existing ACPDB box inside(with labels)
Existing Rectifier Rack inside
DC Breakers with lable
Existing RF antenna (all operator) (need to check the space to installe antennas)l
Existing MW IDU
Existing Tower
Existing vertical cable ladder
Existing horizontal cable ladder
Evidence of Crane(if need Crane)
Location for ZTE Equipment( if can pre-installation)(Proposed Location)
IDU Grounding(ECB end)
ODU Grounding(ECB or Tower end)
All ECB connection ponit (Should be clearly visible)
Cable Entry Port Photo(To be taken parralally to horiziontal)
Meter Cubical Photo (front & back)
CW Defects #1
CW Defects #2
Exisiting TMA (Sector A)
Exisiting TMA (Sector B)
Exisiting TMA (Sector C)
TSSR for Swap Site
<本文中的所有信息均为中兴通讯股份有限公司内部信息,未经允许,不得外传> 共 43 页 , 第 16 页
If taken
TSSR for Swap Site
5
4. Site Sketch(The drawing should be clear)
4.1 Site Location Map
TSSR for Swap Site
5
4.2 Outside existing layout diagram (outside of cabin) : Include all operators
4.3 ZTE proposed Outside layout sketch
TSSR for Swap Site
5
4.4 Inside site layout diagram (inside cabin): Include all operators
TSSR for Swap Site
5
4.5 ZTE proposed Equipment location Inside Cabin layout sketch
TSSR for Swap Site
5
4.6 Cable ladder diagram for inside cabin separately.
TSSR for Swap Site
5
4.7 Elevation of Tower for Existing Antenna ( All antenna mounted points should clearly visible)
TSSR for Swap Site
5
4.8 Elevation of Tower for proposed ZTE Antenna ( All antenna mounted points should clearly visible)
TSSR for Swap Site
5
4.9 Vertical cable ladder diagram ( for additional cable and additional ladder or Extension Bars)
TSSR for Swap Site
5
4.10 Horizontal cable ladder diagram( plan View) ( for additional cable and additional ladder)
TSSR for Swap Site
5
4.10 Horizontal cable ladder diagram( Elevation View) ( for additional cable and additional ladder)
TSSR for Swap Site
5
4.11 RF Connection Scheme(include the feeder,fiber and power cables)(from antenna to BTS/Nodeb in all detail).
TSSR for Swap Site
5
No GSM Material list Detail Description1 ZXDU 68 w201 Rack with CSU Battery Temp Sensros 12 BBU with all cards(With ALL CARDS CC / UBPG/ FS,etc…) 13 ZXDU 68 W201 Accesseries |+ZXD2400(V4.0) 30A Rectifier| -3+ Battery Cable 14 12V135Ah Gel VRLA Battery 165 Battery Racks(For 2 BB) 16 RC 8910 Rack assembly(1800) 17 RSU 80W 900M 38 RSU to FS Fiber
9 RRU 1800M 310 Installation Accessories 111 Feeder Cable
12 Fiber Cable 1800
13 Feeder Clamp
14 Fiber Clamp
15 Power clamp
16 Feeder earth kit
17 Fiber earth Kit
18 ECBs 119 ANT Jumper Cable(RF-08700-029) L
20 ANT Jumper Cable (RF-96514-016) S
21 RF Feeder Connector
22 SFP ports 6
26 FCE monitor combine cable (between 2 BC8910 FCE) 1
27 blue outdoor cable 25mm 1628 black outdoor cable 25mm 1629 Ground cab cable 25mm 1030 Green outdoor cable 35mm
31 Digital Distribution Moudle |FMPX529-DDF75//SM19JA 132 DC Cable (16mm) Black 1533 DC Cable(16mm) Blue 1534 Inter RSU Cables (TX/RX) 635 TMA 336 Bias t 337 Bais t cabes 338 Antenna -900 039 Antenna - 1800 340 Clamps - 738546 for 1800 KATHREIN Antenna 341 Bracket - 732317 for 1800 KATHREIN Antenna 642 Antenna - Dual band 043 Antenna - Triple-band 046 4×6mm2 power cord 1047 4×16mm2 power cord 048 Metal tube with PVC surface 2549 20
★QTY
yellow/green Grunding cable 16mm2
50 ACDB for outdoor site 151 SPD1 V25-B+C/3 320V,C25-B+C/NPE-255V 152 SRF SF340A-NE-SG 153 40A4P MCB
54 3900 Convertion Plates 355 39012 Convertion Plates
56 APM 200 Convertion Plates
57 ZTE Pinth GF
58 ZTE Pinth RT
59 Cabe Tray GF
60 Cabe Tray RT
61 Extension Bar
62 Nut & Bolt for Plinth 12
63 GI pipe for power cable with connection joints (units in Bars, 1 Bar=5.8 m) 064 Antenna Bracket (Antenna Mounting Poles ) 3
65 SPD ACBD POLE Without Base Plate GF with End Cap 166 SPD ACBD POLE With Base Plate RT with End Cap 167 Meter Cubical
UNIT★
Box
BoxBox
Box
BoxBoxmm
Box
Pcs
Pcs
MMM
Pcs
MM
PcsPcsPcsPcsPcsPcsPcsPcsPcsPcsMMMM
setsetsetPcs
EachEachEachPcsPcsPcsPcsPcsPcsPcsSet
EachEach
UMTS Material list Detail Description1 ZXDU 68 w201 Rack with CSU Battery Temp Sensros
2 BBU with all cards(With ALL CARDS CC / UBPG/ FS,etc…)
3 ZXDU 68 W201 Accesseries |+ZXD2400(V4.0) 30A Rectifier| -3+ Battery Cable
4 12V135Ah Gel VRLA Battery
5 Battery Raks(For 2 BB)
6 RC 8910 Rack assembly(1800)
7 RRU
8 Installation Accessories
9 Fiber Cable
10 Fiber Clamp
11 Power clamp
12 Fiber earth Kit
13 ECBs
14 Digital Distribution Moudle |FMPX529-DDF75//SM19JA
15 Antenna - Dual band Directional Antenna | 5755.00//742266//CNPX308M-4P-E1//DBXLH-6565C-VTM
16 Antenna - Triple-band 65degree dual porlarization (6ports) RET Antenna
17 RF-08700-029 | 626970000100 V1.5
18 Metal tube with PVC surface
19 Earth Cable 25mm
20 Earth Cable 35mm
21 DC Cable (16mm) Black
22 DC Cable(16mm) Blue
23 3900 Conversion Plate
24 3012 Converstion Plate
25 3012 Battery Converstion Plate
26 APM200 Converstion Plate
27 ACDB for outdoor site28 SPD1 V25-B+C/3 320V,C25-B+C/NPE-255V
29 SRF SF340A-NE-SG
30 4×6mm2 power cord
31 4×16mm2 power cord
32 GI pipe for power cable with connection joints (units in Bars, 1 Bar=5.8 m)
33 Nut & Bolts for Plinth34 Meter Cubical
QTY★ UNIT★
1 Box11 Box
16 Box113 Box1 Box
1 Box1 Pcs0 Pcs3 Pcs6 Pcs
20 M
20 MM
15 M15 M1 Pcs0 Pcs0 Pcs0 Pcs0 set0 set0 set
10 M0 M
1 Pcs4 Pcs