tubing pumps reglo-e dc motor with optical encoder oem · motor light barrier k pin 1 gnd pin 2 +...

15
OEM Side view (mm) Front view (mm) + + 1 2 3 Motor Light barrier k PIN 1 GND PIN 2 + 5V PIN 3 Frequency output (TTL level) DC motor with optical encoder and gear box Diagram and electrical connections Mounting cut-out (mm) Tubing pumps REGLO-E 02.3.6 30.09.05 Data sheet ISMATEC SA, A Unit of IDEX Corporation, Feldeggstrasse 6, CH-8152 Glattbrugg, Switzerland Phone +41 (0)44 874 94 94, Fax +41 (0)44 810 52 92, [email protected], www.ismatec.com ISO 9001 ca. 0.002–38.4 * ml/min 26 105 23 3 88 90 40 1 channel 12 rollers Technical specifications Pump model REGLO-E MS/CA1-12 Motor type DC motor with encoder Gear ratio 25:1 Rotation speed* 3.2–160 rpm a ) 1.6–160 rpm b ) Flow rates* 0.002–38.4 ml/min Motor control* optional control unit Power consumption max. 10 W Optical encoder 120 impulses/motor rev. Channels 1 Pump rollers 12 Weight 0.560 kg Tubing type 3-stop collared tubing Tubing i.d. 0.13–3.17 mm Cassettes MS/CA Click'n'go, POM Cassettes (Spare part / Option) IS 3510 MS/CA Click'n'go, POM-C 2 ) IS 0649 MS/CA Pressure lever, POM-C IS 3629 MS/CA Pressure lever, PVDF 2 ) Standard equipment k Please see data sheet 09.1 Flow rates 1 ) Tubing ml per Tubing ml per i.d. mm revolution i.d. mm revolution 0.13 0.00093 1.14 0.067 0.19 0.0021 1.22 0.075 0.25 0.0038 1.30 0.083 0.38 0.0088 1.42 0.094 0.44 0.012 1.52 0.10 0.51 0.016 1.65 0.12 0.57 0.019 1.75 0.13 0.64 0.024 1.85 0.13 0.76 0.033 2.06 0.15 0.89 0.044 2.29 0.17 0.95 0.050 2.54 0.19 1.02 0.056 2.79 0.21 1.09 0.063 3.17 0.24 1 ) Water, Tygon ® tubing, without differential pressure k Calculation example for flow rate rpm x ml per revolution = ml/min 160 x 0.24 = 38.4 Ask for the ISMATEC ® Pump Tubing Selection Guide. Nominal voltage Type REGLO-E MS/CA1-12 Order No. 12 V DC IS 3258 Ordering information Please note Specifications valid for the following ISMATEC ® control units: a ) REGLO-E Analog - see data sheet 08.1 b ) REGLO-E Digital - see data sheet 08.2 *

Upload: others

Post on 01-Nov-2019

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Tubing pumps REGLO-E DC motor with optical encoder OEM · Motor Light barrier k PIN 1 GND PIN 2 + 5V PIN 3 Frequency output (TTL level) DC motor with optical encoder and gear box

OEMSide view (mm)

Front view (mm)

+

+123

Motor

Light barrier

k

PIN 1 GNDPIN 2 + 5VPIN 3 Frequency output (TTL level)

DC motor with optical encoderand gear box

Diagram and electrical connections

Mounting cut-out (mm)

Tubing pumps REGLO-E

0 2 . 3 . 6 3 0 . 0 9 . 0 5

Data

shee

t

ISMATEC SA, A Unit of IDEX Corporation, Feldeggstrasse 6, CH-8152 Glattbrugg, SwitzerlandPhone +41 (0)44 874 94 94, Fax +41 (0)44 810 52 92, [email protected], www.ismatec.com ISO

9001

ca. 0.002–38.4* ml/min

26

105 233

88

9040

1channel

12rollers

Technical specifi cationsPump model REGLO-E MS/CA1-12Motor type DC motor with encoderGear ratio 25:1Rotation speed* 3.2–160 rpm a) 1.6–160 rpm b) Flow rates* 0.002–38.4 ml/min Motor control* optional control unitPower consumption max. 10 WOptical encoder 120 impulses/motor rev.Channels 1Pump rollers 12Weight 0.560 kgTubing type 3-stop collared tubingTubing i.d. 0.13–3.17 mmCassettes MS/CA Click'n'go, POM

Cassettes (Spare part / Option)IS 3510 MS/CA Click'n'go, POM-C 2)IS 0649 MS/CA Pressure lever, POM-CIS 3629 MS/CA Pressure lever, PVDF

2) Standard equipmentk Please see data sheet 09.1

Flow rates1) Tubing ml per Tubing ml per i.d. mm revolution i.d. mm revolution 0.13 0.00093 1.14 0.067 0.19 0.0021 1.22 0.075 0.25 0.0038 1.30 0.083 0.38 0.0088 1.42 0.094 0.44 0.012 1.52 0.10 0.51 0.016 1.65 0.12 0.57 0.019 1.75 0.13 0.64 0.024 1.85 0.13 0.76 0.033 2.06 0.15 0.89 0.044 2.29 0.17 0.95 0.050 2.54 0.19 1.02 0.056 2.79 0.21 1.09 0.063 3.17 0.241) Water, Tygon® tubing, without differential pressure

k Calculation example for fl ow rate rpm x ml per revolution = ml/min 160 x 0.24 = 38.4

Ask for the ISMATEC® Pump Tubing Selection Guide.

Nominal voltage Type REGLO-E MS/CA1-12 Order No. 12 VDC IS 3258

Ordering information

Please note

Specifi cations valid for the followingISMATEC® control units:a) REGLO-E Analog - see data sheet 08.1b) REGLO-E Digital - see data sheet 08.2

*

Page 2: Tubing pumps REGLO-E DC motor with optical encoder OEM · Motor Light barrier k PIN 1 GND PIN 2 + 5V PIN 3 Frequency output (TTL level) DC motor with optical encoder and gear box

OEMSide view (mm)

Front view (mm)

+

+123

Motor

Light barrier

k

PIN 1 GNDPIN 2 + 5VPIN 3 Frequency output (TTL level)

DC motor with optical encoderand gear box

Diagram and electrical connections

Mounting cut-out (mm)

Tubing pumps REGLO-E

0 2 . 3 . 5 3 0 . 0 9 . 0 5

Data

shee

t

ISMATEC SA, A Unit of IDEX Corporation, Feldeggstrasse 6, CH-8152 Glattbrugg, SwitzerlandPhone +41 (0)44 874 94 94, Fax +41 (0)44 810 52 92, [email protected], www.ismatec.com ISO

9001

26

105 233

ca. 0.002–56* ml/min1

channel8

rollers

Technical specifi cationsPump model REGLO-E MS/CA1-08Motor type DC motor with encoderGear ratio 25:1Rotation speed* 3.2–160 rpm a) 1.6–160 rpm b) Flow rates* 0.002–56 ml/min Motor control* optional control unitPower consumption max. 10 WOptical encoder 120 impulses/motor rev.Channels 1Pump rollers 8Weight 0.560 kgTubing type 3-stop collared tubingTubing i.d. 0.13–3.17 mmCassettes MS/CA Click'n'go, POM

Cassettes (Spare part / Option)IS 3510 MS/CA Click'n'go, POM-C 2)IS 0649 MS/CA Pressure lever, POM-CIS 3629 MS/CA Pressure lever, PVDF

2) Standard equipmentk Please see data sheet 09.1

Flow rates1) Tubing ml per Tubing ml per i.d. mm revolution i.d. mm revolution 0.13 0.0011 1.14 0.078 0.19 0.0023 1.22 0.088 0.25 0.0041 1.30 0.098 0.38 0.0094 1.42 0.11 0.44 0.013 1.52 0.13 0.51 0.017 1.65 0.15 0.57 0.021 1.75 0.16 0.64 0.026 1.85 0.17 0.76 0.036 2.06 0.20 0.89 0.049 2.29 0.24 0.95 0.056 2.54 0.27 1.02 0.063 2.79 0.31 1.09 0.072 3.17 0.351) Water, Tygon® tubing, without differential pressure

k Calculation example for fl ow rate rpm x ml per revolution = ml/min 160 x 0.35 = 56

Ask for the ISMATEC® Pump Tubing Selection Guide.

Nominal voltage Type REGLO-E MS/CA1-08 Order No. 12 VDC IS 3206

Ordering information

Please note

Specifi cations valid for the followingISMATEC® control units:a) REGLO-E Analog - see data sheet 08.1b) REGLO-E Digital - see data sheet 08.2

*

Page 3: Tubing pumps REGLO-E DC motor with optical encoder OEM · Motor Light barrier k PIN 1 GND PIN 2 + 5V PIN 3 Frequency output (TTL level) DC motor with optical encoder and gear box

OEMSide view (mm)

Front view (mm)

+

+123

Motor

Light barrier

k

PIN 1 GNDPIN 2 + 5VPIN 3 Frequency output (TTL level)

DC motor with optical encoderand gear box

Diagram and electrical connections

Mounting cut-out (mm)

Tubing pumps REGLO-E

0 2 . 3 . 4 3 0 . 0 9 . 0 5

Data

shee

t

ISMATEC SA, A Unit of IDEX Corporation, Feldeggstrasse 6, CH-8152 Glattbrugg, SwitzerlandPhone +41 (0)44 874 94 94, Fax +41 (0)44 810 52 92, [email protected], www.ismatec.com ISO

9001

26

105 233

ca. 0.003–68.8*ml/min1

channel 6

rollers

Technical specifi cationsPump model REGLO-E MS/CA1-06Motor type DC motor with encoderGear ratio 25:1Rotation speed* 3.2–160 rpm a) 1.6–160 rpm b)Flow rates* 0.003–68.8 ml/min Motor control* optional control unitPower consumption max. 10 WOptical encoder 120 impulses/motor rev.Channels 1Pump rollers 6Weight 0.560 kgTubing type 3-stop collared tubingTubing i.d. 0.13–3.17 mmCassettes MS/CA Click'n'go, POM

Cassettes (Spare part / Option)IS 3510 MS/CA Click'n'go, POM-C 2)IS 0649 MS/CA Pressure lever, POM-CIS 3629 MS/CA Pressure lever, PVDF

2) Standard equipmentk Please see data sheet 09.1

Flow rates1) Tubing ml per Tubing ml per i.d. mm revolution i.d. mm revolution 0.13 0.0014 1.14 0.09 0.19 0.0028 1.22 0.10 0.25 0.0048 1.30 0.11 0.38 0.011 1.42 0.13 0.44 0.014 1.52 0.15 0.51 0.019 1.65 0.17 0.57 0.024 1.75 0.19 0.64 0.030 1.85 0.21 0.76 0.042 2.06 0.25 0.89 0.057 2.29 0.29 0.95 0.064 2.54 0.33 1.02 0.073 2.79 0.37 1.09 0.083 3.17 0.431) Water, Tygon® tubing, without differential pressure

k Calculation example for flow rate rpm x ml per revolution = ml/min 160 x 0.43 = 68.8

Ask for the ISMATEC® Pump Tubing Selection Guide.

Nominal voltage Type REGLO-E MS/CA1-06 Order No. 12 VDC IS 3205 24 VDC IS 3205A

Ordering information

Please note

Specifi cations valid for the followingISMATEC® control units:a) REGLO-E Analog - see data sheet 08.1b) REGLO-E Digital - see data sheet 08.2

*

Page 4: Tubing pumps REGLO-E DC motor with optical encoder OEM · Motor Light barrier k PIN 1 GND PIN 2 + 5V PIN 3 Frequency output (TTL level) DC motor with optical encoder and gear box

OEMSide view (mm)

Front view (mm)

+

+123

Motor

Light barrier

k

PIN 1 GNDPIN 2 + 5VPIN 3 Frequency output (TTL level)

DC motor with optical encoderand gear box

Diagram and electrical connections

Mounting cut-out (mm)

Tubing pumps REGLO-E

0 2 . 3 . 9 3 0 . 0 9 . 0 5

Data

shee

t

ISMATEC SA, A Unit of IDEX Corporation, Feldeggstrasse 6, CH-8152 Glattbrugg, SwitzerlandPhone +41 (0)44 874 94 94, Fax +41 (0)44 810 52 92, [email protected], www.ismatec.com ISO

9001

88

9040

39

105 3 36

ca. 0.002–38.4* ml/min2

channels 12rollers

Ordering information

Nominal voltage Type REGLO-E MS/CA2-12 Order No. 12 VDC IS 3124

Flow rates1) Tubing ml per Tubing ml per i.d. mm revolution i.d. mm revolution 0.13 0.00093 1.14 0.067 0.19 0.0021 1.22 0.075 0.25 0.0038 1.30 0.083 0.38 0.0088 1.42 0.094 0.44 0.012 1.52 0.10 0.51 0.016 1.65 0.12 0.57 0.019 1.75 0.13 0.64 0.024 1.85 0.13 0.76 0.033 2.06 0.15 0.89 0.044 2.29 0.17 0.95 0.050 2.54 0.19 1.02 0.056 2.79 0.21 1.09 0.063 3.17 0.241) Water, Tygon® tubing, without differential pressure

k Calculation example for fl ow rate rpm x ml per revolution = ml/min 160 x 0.24 = 38.4

Ask for the ISMATEC® Pump Tubing Selection Guide.

Technical specifi cationsPump model REGLO-E MS/CA2-12Motor type DC motor with encoderGear ratio 25:1Rotation speed* 3.2–160 rpm a) 1.6–160 rpm b) Flow rates* 0.002–38.4 ml/min Motor control* optional control unitPower consumption max. 10 WOptical encoder 120 impulses/motor rev.Channels 2Pump rollers 12Weight 0.620 kgTubing type 3-stop collared tubingTubing i.d. 0.13–3.17 mmCassettes MS/CA Click'n'go, POM

Cassettes (Spare part / Option)IS 3510 MS/CA Click'n'go, POM-C 2)IS 0649 MS/CA Pressure lever, POM-CIS 3629 MS/CA Pressure lever, PVDF

2) Standard equipmentk Please see data sheet 09.1

Please note

Specifi cations valid for the followingISMATEC® control units:a) REGLO-E Analog - see data sheet 08.1b) REGLO-E Digital - see data sheet 08.2

*

Page 5: Tubing pumps REGLO-E DC motor with optical encoder OEM · Motor Light barrier k PIN 1 GND PIN 2 + 5V PIN 3 Frequency output (TTL level) DC motor with optical encoder and gear box

OEMSide view (mm)

Front view (mm)

+

+123

Motor

Light barrier

k

PIN 1 GNDPIN 2 + 5VPIN 3 Frequency output (TTL level)

DC motor with optical encoderand gear box

Diagram and electrical connections

Mounting cut-out (mm)

Tubing pumps REGLO-E

0 2 . 3 . 8 3 0 . 0 9 . 0 5

Data

shee

t

ISMATEC SA, A Unit of IDEX Corporation, Feldeggstrasse 6, CH-8152 Glattbrugg, SwitzerlandPhone +41 (0)44 874 94 94, Fax +41 (0)44 810 52 92, [email protected], www.ismatec.com ISO

9001

ca. 0.002–56* ml/min

39

105 3 36

88

9040

Nominal voltage Type REGLO-E MS/CA2-08 Order No. 12 VDC IS 3181

Ordering information

2channels

8rollers

Flow rates1) Tubing ml per Tubing ml per i.d. mm revolution i.d. mm revolution 0.13 0.0011 1.14 0.078 0.19 0.0023 1.22 0.088 0.25 0.0041 1.30 0.098 0.38 0.0094 1.42 0.11 0.44 0.013 1.52 0.13 0.51 0.017 1.65 0.15 0.57 0.021 1.75 0.16 0.64 0.026 1.85 0.17 0.76 0.036 2.06 0.20 0.89 0.049 2.29 0.24 0.95 0.056 2.54 0.27 1.02 0.063 2.79 0.31 1.09 0.072 3.17 0.351) Water, Tygon® tubing, without differential pressure

k Calculation example for fl ow rate rpm x ml per revolution = ml/min 160 x 0.35 = 56

Ask for the ISMATEC® Pump Tubing Selection Guide.

Technical specifi cationsPump model REGLO-E MS/CA2-08Motor type DC motor with encoderGear ratio 25:1Rotation speed* 3.2–160 rpm a) 1.6–160 rpm b) Flow rates* 0.002 –56 ml/min Motor control* optional control unitPower consumption max. 10 WOptical encoder 120 impulses/motor rev.Channels 2Pump rollers 8Weight 0.620 kgTubing type 3-stop collared tubingTubing i.d. 0.13–3.17 mmCassettes MS/CA Click'n'go, POM

Cassettes (Spare part / Option)IS 3510 MS/CA Click'n'go, POM-C 2)IS 0649 MS/CA Pressure lever, POM-CIS 3629 MS/CA Pressure lever, PVDF

2) Standard equipmentk Please see data sheet 09.1

Please note

Specifi cations valid for the followingISMATEC® control units:a) REGLO-E Analog - see data sheet 08.1b) REGLO-E Digital - see data sheet 08.2

*

Page 6: Tubing pumps REGLO-E DC motor with optical encoder OEM · Motor Light barrier k PIN 1 GND PIN 2 + 5V PIN 3 Frequency output (TTL level) DC motor with optical encoder and gear box

OEMSide view (mm)

Front view (mm)

+

+123

Motor

Light barrier

k

PIN 1 GNDPIN 2 + 5VPIN 3 Frequency output (TTL level)

DC motor with optical encoderand gear box

Diagram and electrical connections

Mounting cut-out (mm)

Tubing pumps REGLO-E

0 2 . 3 . 7 3 0 . 0 9 . 0 5

Data

shee

t

ISMATEC SA, A Unit of IDEX Corporation, Feldeggstrasse 6, CH-8152 Glattbrugg, SwitzerlandPhone +41 (0)44 874 94 94, Fax +41 (0)44 810 52 92, [email protected], www.ismatec.com ISO

9001

88

9040

39

105 3 36

ca. 0.003–68.8* ml/min2

channels6

rollers

Technical specifi cationsPump model REGLO-E MS/CA2-06Motor type DC motor with encoderGear ratio 25:1Rotation speed* 3.2–160 rpm a) 1.6–160 rpm b) Flow rates* 0.003–68.8 ml/min Motor control* optional control unitPower consumption max. 10 WOptical encoder 120 impulses/motor rev.Channels 2Pump rollers 6Weight 0.620 kgTubing type 3-stop collared tubingTubing i.d. 0.13–3.17 mmCassettes MS/CA Click'n'go, POM

Cassettes (Spare part / Option)IS 3510 MS/CA Click'n'go, POM-C 2)IS 0649 MS/CA Pressure lever, POM-CIS 3629 MS/CA Pressure lever, PVDF

2) Standard equipmentk Please see data sheet 09.1

Flow rates1) Tubing ml per Tubing ml per i.d. mm revolution i.d. mm revolution 0.13 0.0014 1.14 0.09 0.19 0.0028 1.22 0.10 0.25 0.0048 1.30 0.11 0.38 0.011 1.42 0.13 0.44 0.014 1.52 0.15 0.51 0.019 1.65 0.17 0.57 0.024 1.75 0.19 0.64 0.030 1.85 0.21 0.76 0.042 2.06 0.25 0.89 0.057 2.29 0.29 0.95 0.064 2.54 0.33 1.02 0.073 2.79 0.37 1.09 0.083 3.17 0.431) Water, Tygon® tubing, without differential pressure

k Calculation example for fl ow rate rpm x ml per revolution = ml/min 160 x 0.43 = 68.8

Ask for the ISMATEC® Pump Tubing Selection Guide.

Nominal voltage Type REGLO-E MS/CA2-06 Order No. 12 VDC IS 3180

Ordering information

Please note

Specifi cations valid for the followingISMATEC® control units:a) REGLO-E Analog - see data sheet 08.1b) REGLO-E Digital - see data sheet 08.2

*

Roller-head supported

Page 7: Tubing pumps REGLO-E DC motor with optical encoder OEM · Motor Light barrier k PIN 1 GND PIN 2 + 5V PIN 3 Frequency output (TTL level) DC motor with optical encoder and gear box

OEMSide view (mm)

Front view (mm)

+

+123

Motor

Light barrier

k

PIN 1 GNDPIN 2 + 5VPIN 3 Frequency output (TTL level)

DC motor with optical encoderand gear box

Diagram and electrical connections

Mounting cut-out (mm)

Tubing pumps REGLO-E

0 2 . 3 . 1 2 3 0 . 0 9 . 0 5

Data

shee

t

ISMATEC SA, A Unit of IDEX Corporation, Feldeggstrasse 6, CH-8152 Glattbrugg, SwitzerlandPhone +41 (0)44 874 94 94, Fax +41 (0)44 810 52 92, [email protected], www.ismatec.com ISO

9001

47

105 3 44

88

9040

ca. 0.001– 24* ml/min3

channels 12rollers

Technical specifi cationsPump model REGLO-E MS/CA3-12Motor type DC motor with encoderGear ratio 25:1Rotation speed* 2–100 rpm a) 1–100 rpm b) Flow rates* 0.001–24 ml/min Motor control* optional control unitPower consumption max. 10 WOptical encoder 120 impulses/motor rev.Channels 3Pump rollers 12Weight 0.700 kgTubing type 3-stop collared tubingTubing i.d. 0.13–3.17 mmCassettes MS/CA Click'n'go, POM

Cassettes (Spare part / Option)IS 3510 MS/CA Click'n'go, POM-C 2)IS 0649 MS/CA Pressure lever, POM-CIS 3629 MS/CA Pressure lever, PVDF

2) Standard equipmentk Please see data sheet 09.1

Flow rates1) Tubing ml per Tubing ml per i.d. mm revolution i.d. mm revolution 0.13 0.00093 1.14 0.067 0.19 0.0021 1.22 0.075 0.25 0.0038 1.30 0.083 0.38 0.0088 1.42 0.094 0.44 0.012 1.52 0.10 0.51 0.016 1.65 0.12 0.57 0.019 1.75 0.13 0.64 0.024 1.85 0.13 0.76 0.033 2.06 0.15 0.89 0.044 2.29 0.17 0.95 0.050 2.54 0.19 1.02 0.056 2.79 0.21 1.09 0.063 3.17 0.241) Water, Tygon® tubing, without differential pressure

k Calculation example for fl ow rate rpm x ml per revolution = ml/min 100 x 0.24 = 24

Ask for the ISMATEC® Pump Tubing Selection Guide.

Nominal voltage Type REGLO-E MS/CA3-12 Order No. 12 VDC IS 3266

Ordering information

Please note

Specifi cations valid for the followingISMATEC® control units:a) REGLO-E Analog - see data sheet 08.1b) REGLO-E Digital - see data sheet 08.2

*

Page 8: Tubing pumps REGLO-E DC motor with optical encoder OEM · Motor Light barrier k PIN 1 GND PIN 2 + 5V PIN 3 Frequency output (TTL level) DC motor with optical encoder and gear box

OEMSide view (mm)

Front view (mm)

+

+123

Motor

Light barrier

k

PIN 1 GNDPIN 2 + 5VPIN 3 Frequency output (TTL level)

DC motor with optical encoderand gear box

Diagram and electrical connections

Mounting cut-out (mm)

Tubing pumps REGLO-E

0 2 . 3 . 1 1 3 0 . 0 9 . 0 5

Data

shee

t

ISMATEC SA, A Unit of IDEX Corporation, Feldeggstrasse 6, CH-8152 Glattbrugg, SwitzerlandPhone +41 (0)44 874 94 94, Fax +41 (0)44 810 52 92, [email protected], www.ismatec.com ISO

9001

47

105 3 44

88

9040

ca. 0.002– 35* ml/min3

channels 8

rollers

Technical specifi cationsPump model REGLO-E MS/CA3-08Motor type DC motor with encoderGear ratio 25:1Rotation speed* 2–100 rpm a) 1–100 rpm b) Flow rates* 0.002–35 ml/min Motor control* optional control unitPower consumption max. 10 WOptical encoder 120 impulses/motor rev.Channels 3Pump rollers 8Weight 0.700 kgTubing type 3-stop collared tubingTubing i.d. 0.13–3.17 mmCassettes MS/CA Click'n'go, POM

Cassettes (Spare part / Option)IS 3510 MS/CA Click'n'go, POM-C 2)IS 0649 MS/CA Pressure lever, POM-CIS 3629 MS/CA Pressure lever, PVDF

2) Standard equipmentk Please see data sheet 09.1

Flow rates1) Tubing ml per Tubing ml per i.d. mm revolution i.d. mm revolution 0.13 0.0011 1.14 0.078 0.19 0.0023 1.22 0.088 0.25 0.0041 1.30 0.098 0.38 0.0094 1.42 0.11 0.44 0.013 1.52 0.13 0.51 0.017 1.65 0.15 0.57 0.021 1.75 0.16 0.64 0.026 1.85 0.17 0.76 0.036 2.06 0.20 0.89 0.049 2.29 0.24 0.95 0.056 2.54 0.27 1.02 0.063 2.79 0.31 1.09 0.072 3.17 0.351) Water, Tygon® tubing, without differential pressure

k Calculation example for fl ow rate rpm x ml per revolution = ml/min 100 x 0.35 = 35

Ask for the ISMATEC® Pump Tubing Selection Guide.

Nominal voltage Type REGLO-E MS/CA3-08 Order No. 12 VDC IS 2872

Ordering information

Please note

Specifi cations valid for the followingISMATEC® control units:a) REGLO-E Analog - see data sheet 08.1b) REGLO-E Digital - see data sheet 08.2

*

Page 9: Tubing pumps REGLO-E DC motor with optical encoder OEM · Motor Light barrier k PIN 1 GND PIN 2 + 5V PIN 3 Frequency output (TTL level) DC motor with optical encoder and gear box

OEMSide view (mm)

Front view (mm)

+

+123

Motor

Light barrier

k

PIN 1 GNDPIN 2 + 5VPIN 3 Frequency output (TTL level)

DC motor with optical encoderand gear box

Diagram and electrical connections

Mounting cut-out (mm)

Tubing pumps REGLO-E

0 2 . 3 . 1 0 3 0 . 0 9 . 0 5

Data

shee

t

ISMATEC SA, A Unit of IDEX Corporation, Feldeggstrasse 6, CH-8152 Glattbrugg, SwitzerlandPhone +41 (0)44 874 94 94, Fax +41 (0)44 810 52 92, [email protected], www.ismatec.com ISO

9001

47

105 3 44

88

9040

ca. 0.002– 43* ml/min3

channels 6

rollers

Technical specifi cationsPump model REGLO-E MS/CA3-06Motor type DC motor with encoderGear ratio 25:1Rotation speed* 2–100 rpm a) 1–100 rpm b) Flow rates* 0.002–43 ml/min Motor control* optional control unitPower consumption max. 10 WOptical encoder 120 impulses/motor rev.Channels 3Pump rollers 6Weight 0.700 kgTubing type 3-stop collared tubingTubing i.d. 0.13–3.17 mmCassettes MS/CA Click'n'go, POM

Cassettes (Spare part / Option)IS 3510 MS/CA Click'n'go, POM-C 2)IS 0649 MS/CA Pressure lever, POM-CIS 3629 MS/CA Pressure lever, PVDF

2) Standard equipmentk Please see data sheet 09.1

Flow rates1) Tubing ml per Tubing ml per i.d. mm revolution i.d. mm revolution 0.13 0.0014 1.14 0.09 0.19 0.0028 1.22 0.10 0.25 0.0048 1.30 0.11 0.38 0.011 1.42 0.13 0.44 0.014 1.52 0.15 0.51 0.019 1.65 0.17 0.57 0.024 1.75 0.19 0.64 0.030 1.85 0.21 0.76 0.042 2.06 0.25 0.89 0.057 2.29 0.29 0.95 0.064 2.54 0.33 1.02 0.073 2.79 0.37 1.09 0.083 3.17 0.431) Water, Tygon® tubing, without differential pressure

k Calculation example for fl ow rate rpm x ml per revolution = ml/min 100 x 0.43 = 43

Ask for the ISMATEC® Pump Tubing Selection Guide.

Nominal voltage Type REGLO-E MS/CA3-06 Order No. 12 VDC IS 2871

Ordering information

Please note

Specifi cations valid for the followingISMATEC® control units:a) REGLO-E Analog - see data sheet 08.1b) REGLO-E Digital - see data sheet 08.2

*

Page 10: Tubing pumps REGLO-E DC motor with optical encoder OEM · Motor Light barrier k PIN 1 GND PIN 2 + 5V PIN 3 Frequency output (TTL level) DC motor with optical encoder and gear box

OEMSide view (mm)

Front view (mm)

+

+123

Motor

Light barrier

k

PIN 1 GNDPIN 2 + 5VPIN 3 Frequency output (TTL level)

DC motor with optical encoderand gear box

Diagram and electrical connections

Mounting cut-out (mm)

Tubing pumps REGLO-E

0 2 . 3 . 1 5 3 0 . 0 9 . 0 5

Data

shee

t

ISMATEC SA, A Unit of IDEX Corporation, Feldeggstrasse 6, CH-8152 Glattbrugg, SwitzerlandPhone +41 (0)44 874 94 94, Fax +41 (0)44 810 52 92, [email protected], www.ismatec.com ISO

9001

105 3 52

55

88

9040

ca. 0.001– 24* ml/min4

channels 12rollers

Technical specifi cationsPump model REGLO-E MS/CA4-12Motor type DC motor with encoderGear ratio 25:1Rotation speed* 2–100 rpm a) 1–100 rpm b) Flow rates* 0.001–24 ml/min Motor control* optional control unitPower consumption max. 10 WOptical encoder 120 impulses/motor rev.Channels 4Pump rollers 12Weight 0.780 kgTubing type 3-stop collared tubingTubing i.d. 0.13–3.17 mmCassettes MS/CA Click'n'go, POM

Cassettes (Spare part / Option)IS 3510 MS/CA Click'n'go, POM-C 2)IS 0649 MS/CA Pressure lever, POM-CIS 3629 MS/CA Pressure lever, PVDF

2) Standard equipmentk Please see data sheet 09.1

Flow rates1) Tubing ml per Tubing ml per i.d. mm revolution i.d. mm revolution 0.13 0.00093 1.14 0.067 0.19 0.0021 1.22 0.075 0.25 0.0038 1.30 0.083 0.38 0.0088 1.42 0.094 0.44 0.012 1.52 0.10 0.51 0.016 1.65 0.12 0.57 0.019 1.75 0.13 0.64 0.024 1.85 0.13 0.76 0.033 2.06 0.15 0.89 0.044 2.29 0.17 0.95 0.050 2.54 0.19 1.02 0.056 2.79 0.21 1.09 0.063 3.17 0.241) Water, Tygon® tubing, without differential pressure

k Calculation example for fl ow rate rpm x ml per revolution = ml/min 100 x 0.24 = 24

Ask for the ISMATEC® Pump Tubing Selection Guide.

Nominal voltage Type REGLO-E MS/CA4-12 Order No. 12 VDC IS 3135

Ordering information

Please note

Specifi cations valid for the followingISMATEC® control units:a) REGLO-E Analog - see data sheet 08.1b) REGLO-E Digital - see data sheet 08.2

*

Page 11: Tubing pumps REGLO-E DC motor with optical encoder OEM · Motor Light barrier k PIN 1 GND PIN 2 + 5V PIN 3 Frequency output (TTL level) DC motor with optical encoder and gear box

OEMSide view (mm)

Front view (mm)

+

+123

Motor

Light barrier

k

PIN 1 GNDPIN 2 + 5VPIN 3 Frequency output (TTL level)

DC motor with optical encoderand gear box

Diagram and electrical connections

Mounting cut-out (mm)

Tubing pumps REGLO-E

0 2 . 3 . 1 4 3 0 . 0 9 . 0 5

Data

shee

t

ISMATEC SA, A Unit of IDEX Corporation, Feldeggstrasse 6, CH-8152 Glattbrugg, SwitzerlandPhone +41 (0)44 874 94 94, Fax +41 (0)44 810 52 92, [email protected], www.ismatec.com ISO

9001

105 3 52

55

88

9040

ca. 0.002– 35* ml/min4

channels 8

rollers

Technical specifi cationsPump model REGLO-E MS/CA4-08Motor type DC motor with encoderGear ratio 25:1Rotation speed* 2–100 rpm a) 1–100 rpm b) Flow rates* 0.002–35 ml/min Motor control* optional control unitPower consumption max. 10 WOptical encoder 120 impulses/motor rev.Channels 4Pump rollers 8Weight 0.780 kgTubing type 3-stop collared tubingTubing i.d. 0.13–3.17 mmCassettes MS/CA Click'n'go, POM

Cassettes (Spare part / Option)IS 3510 MS/CA Click'n'go, POM-C 2)IS 0649 MS/CA Pressure lever, POM-CIS 3629 MS/CA Pressure lever, PVDF

2) Standard equipmentk Please see data sheet 09.1

Flow rates1) Tubing ml per Tubing ml per i.d. mm revolution i.d. mm revolution 0.13 0.0011 1.14 0.078 0.19 0.0023 1.22 0.088 0.25 0.0041 1.30 0.098 0.38 0.0094 1.42 0.11 0.44 0.013 1.52 0.13 0.51 0.017 1.65 0.15 0.57 0.021 1.75 0.16 0.64 0.026 1.85 0.17 0.76 0.036 2.06 0.20 0.89 0.049 2.29 0.24 0.95 0.056 2.54 0.27 1.02 0.063 2.79 0.31 1.09 0.072 3.17 0.351) Water, Tygon® tubing, without differential pressure

k Calculation example for fl ow rate rpm x ml per revolution = ml/min 100 x 0.35 = 35

Ask for the ISMATEC® Pump Tubing Selection Guide.

Nominal voltage Type REGLO-E MS/CA4-08 Order No. 12 VDC IS 3183

Ordering information

Please note

Specifi cations valid for the followingISMATEC® control units:a) REGLO-E Analog - see data sheet 08.1b) REGLO-E Digital - see data sheet 08.2

*

Page 12: Tubing pumps REGLO-E DC motor with optical encoder OEM · Motor Light barrier k PIN 1 GND PIN 2 + 5V PIN 3 Frequency output (TTL level) DC motor with optical encoder and gear box

OEMSide view (mm)

Front view (mm)

+

+123

Motor

Light barrier

k

PIN 1 GNDPIN 2 + 5VPIN 3 Frequency output (TTL level)

DC motor with optical encoderand gear box

Diagram and electrical connections

Mounting cut-out (mm)

Tubing pumps REGLO-E

0 2 . 3 . 1 3 3 0 . 0 9 . 0 5

Data

shee

t

ISMATEC SA, A Unit of IDEX Corporation, Feldeggstrasse 6, CH-8152 Glattbrugg, SwitzerlandPhone +41 (0)44 874 94 94, Fax +41 (0)44 810 52 92, [email protected], www.ismatec.com ISO

9001

105 3 52

55

88

9040

ca. 0.002– 43* ml/min4

channels 6

rollers

Technical specifi cationsPump model REGLO-E MS/CA4-06Motor type DC motor with encoderGear ratio 25:1Rotation speed* 2–100 rpm a) 1–100 rpm b) Flow rates* 0.002–43 ml/min Motor control* optional control unitPower consumption max. 10 WOptical encoder 120 impulses/motor rev.Channels 4Pump rollers 6Weight 0.780 kgTubing type 3-stop collared tubingTubing i.d. 0.13–3.17 mmCassettes MS/CA Click'n'go, POM

Cassettes (Spare part / Option)IS 3510 MS/CA Click'n'go, POM-C 2)IS 0649 MS/CA Pressure lever, POM-CIS 3629 MS/CA Pressure lever, PVDF

2) Standard equipmentk Please see data sheet 09.1

Flow rates1) Tubing ml per Tubing ml per i.d. mm revolution i.d. mm revolution 0.13 0.0014 1.14 0.09 0.19 0.0028 1.22 0.10 0.25 0.0048 1.30 0.11 0.38 0.011 1.42 0.13 0.44 0.014 1.52 0.15 0.51 0.019 1.65 0.17 0.57 0.024 1.75 0.19 0.64 0.030 1.85 0.21 0.76 0.042 2.06 0.25 0.89 0.057 2.29 0.29 0.95 0.064 2.54 0.33 1.02 0.073 2.79 0.37 1.09 0.083 3.17 0.431) Water, Tygon® tubing, without differential pressure

k Calculation example for fl ow rate rpm x ml per revolution = ml/min 100 x 0.43 = 43

Ask for the ISMATEC® Pump Tubing Selection Guide.

Nominal voltage Type REGLO-E MS/CA4-06 Order No. 12 VDC IS 3182

Ordering information

Please note

Specifi cations valid for the followingISMATEC® control units:a) REGLO-E Analog - see data sheet 08.1b) REGLO-E Digital - see data sheet 08.2

*

Page 13: Tubing pumps REGLO-E DC motor with optical encoder OEM · Motor Light barrier k PIN 1 GND PIN 2 + 5V PIN 3 Frequency output (TTL level) DC motor with optical encoder and gear box

OEMSide view (mm)

Front view (mm)

+

+123

Motor

Light barrier

k

PIN 1 GNDPIN 2 + 5VPIN 3 Frequency output (TTL level)

DC motor with optical encoderand gear box

Diagram and electrical connections

Mounting cut-out (mm)

Tubing pumps REGLO-E

0 2 . 3 . 1 8 3 0 . 0 9 . 0 5

Data

shee

t

ISMATEC SA, A Unit of IDEX Corporation, Feldeggstrasse 6, CH-8152 Glattbrugg, SwitzerlandPhone +41 (0)44 874 94 94, Fax +41 (0)44 810 52 92, [email protected], www.ismatec.com ISO

9001

63

105 3 60

88

9040

ca. 0.001– 24* ml/min5

channels 12rollers

Technical specifi cationsPump model REGLO-E MS/CA5-12Motor type DC motor with encoderGear ratio 25:1Rotation speed* 2–100 rpm a) 1–100 rpm b) Flow rates* 0.001–24 ml/min Motor control* optional control unitPower consumption max. 10 WOptical encoder 120 impulses/motor rev.Channels 5Pump rollers 12Weight 0.860 kgTubing type 3-stop collared tubingTubing i.d. 0.13–3.17 mmCassettes MS/CA Click'n'go, POM

Cassettes (Spare part / Option)IS 3510 MS/CA Click'n'go, POM-C 2)IS 0649 MS/CA Pressure lever, POM-CIS 3629 MS/CA Pressure lever, PVDF

2) Standard equipmentk Please see data sheet 09.1

Flow rates1) Tubing ml per Tubing ml per i.d. mm revolution i.d. mm revolution 0.13 0.00093 1.14 0.067 0.19 0.0021 1.22 0.075 0.25 0.0038 1.30 0.083 0.38 0.0088 1.42 0.094 0.44 0.012 1.52 0.10 0.51 0.016 1.65 0.12 0.57 0.019 1.75 0.13 0.64 0.024 1.85 0.13 0.76 0.033 2.06 0.15 0.89 0.044 2.29 0.17 0.95 0.050 2.54 0.19 1.02 0.056 2.79 0.21 1.09 0.063 3.17 0.241) Water, Tygon® tubing, without differential pressure

k Calculation example for fl ow rate rpm x ml per revolution = ml/min 100 x 0.24 = 24

Ask for the ISMATEC® Pump Tubing Selection Guide.

Nominal voltage Type REGLO-E MS/CA5-12 Order No. 12 VDC IS 3347

Ordering information

Please note

Specifi cations valid for the followingISMATEC® control units:a) REGLO-E Analog - see data sheet 08.1b) REGLO-E Digital - see data sheet 08.2

*

Page 14: Tubing pumps REGLO-E DC motor with optical encoder OEM · Motor Light barrier k PIN 1 GND PIN 2 + 5V PIN 3 Frequency output (TTL level) DC motor with optical encoder and gear box

OEMSide view (mm)

Front view (mm)

+

+123

Motor

Light barrier

k

PIN 1 GNDPIN 2 + 5VPIN 3 Frequency output (TTL level)

DC motor with optical encoderand gear box

Diagram and electrical connections

Mounting cut-out (mm)

Tubing pumps REGLO-E

0 2 . 3 . 1 7 3 0 . 0 9 . 0 5

Data

shee

t

ISMATEC SA, A Unit of IDEX Corporation, Feldeggstrasse 6, CH-8152 Glattbrugg, SwitzerlandPhone +41 (0)44 874 94 94, Fax +41 (0)44 810 52 92, [email protected], www.ismatec.com ISO

9001

63

105 3 60

88

9040

ca. 0.002– 35* ml/min5channels

8rollers

Technical specifi cationsPump model REGLO-E MS/CA5-08Motor type DC motor with encoderGear ratio 25:1Rotation speed* 2–100 rpm a) 1–100 rpm b) Flow rates* 0.002 – 35 ml/min Motor control* optional control unitPower consumption max. 10 WOptical encoder 120 impulses/motor rev.Channels 5Pump rollers 8Weight 0.860 kgTubing type 3-stop collared tubingTubing i.d. 0.13–3.17 mmCassettes MS/CA Click'n'go, POM

Cassettes (Spare part / Option)IS 3510 MS/CA Click'n'go, POM-C 2)IS 0649 MS/CA Pressure lever, POM-CIS 3629 MS/CA Pressure lever, PVDF

2) Standard equipmentk Please see data sheet 09.1

Flow rates1) Tubing ml per Tubing ml per i.d. mm revolution i.d. mm revolution 0.13 0.0011 1.14 0.078 0.19 0.0023 1.22 0.088 0.25 0.0041 1.30 0.098 0.38 0.0094 1.42 0.11 0.44 0.013 1.52 0.13 0.51 0.017 1.65 0.15 0.57 0.021 1.75 0.16 0.64 0.026 1.85 0.17 0.76 0.036 2.06 0.20 0.89 0.049 2.29 0.24 0.95 0.056 2.54 0.27 1.02 0.063 2.79 0.31 1.09 0.072 3.17 0.351) Water, Tygon® tubing, without differential pressure

k Calculation example for fl ow rate rpm x ml per revolution = ml/min 100 x 0.35 = 35

Ask for the ISMATEC® Pump Tubing Selection Guide.

Nominal voltage Type REGLO-E MS/CA5-08 Order No. 12 VDC IS 3185

Ordering information

Please note

Specifi cations valid for the followingISMATEC® control units:a) REGLO-E Analog - see data sheet 08.1b) REGLO-E Digital - see data sheet 08.2

*

Page 15: Tubing pumps REGLO-E DC motor with optical encoder OEM · Motor Light barrier k PIN 1 GND PIN 2 + 5V PIN 3 Frequency output (TTL level) DC motor with optical encoder and gear box

OEMSide view (mm)

Front view (mm)

+

+123

Motor

Light barrier

k

PIN 1 GNDPIN 2 + 5VPIN 3 Frequency output (TTL level)

DC motor with optical encoderand gear box

Diagram and electrical connections

Mounting cut-out (mm)

Tubing pumps REGLO-E

0 2 . 3 . 1 6 3 0 . 0 9 . 0 5

Data

shee

t

ISMATEC SA, A Unit of IDEX Corporation, Feldeggstrasse 6, CH-8152 Glattbrugg, SwitzerlandPhone +41 (0)44 874 94 94, Fax +41 (0)44 810 52 92, [email protected], www.ismatec.com ISO

9001

63

105 3 60

88

9040

ca. 0.002– 43* ml/min5

channels 6

rollers

Technical specifi cationsPump model REGLO-E MS/CA5-06Motor type DC motor with encoderGear ratio 25:1Rotation speed* 2–100 rpm a) 1–100 rpm b) Flow rates* 0.002–43 ml/min Motor control* optional control unitPower consumption max. 10 WOptical encoder 120 impulses/motor rev.Channels 5Pump rollers 6Weight 0.860 kgTubing type 3-stop collared tubingTubing i.d. 0.13–3.17 mmCassettes MS/CA Click'n'go, POM

Cassettes (Spare part / Option)IS 3510 MS/CA Click'n'go, POM-C 2)IS 0649 MS/CA Pressure lever, POM-CIS 3629 MS/CA Pressure lever, PVDF

2) Standard equipmentk Please see data sheet 09.1

Flow rates1) Tubing ml per Tubing ml per i.d. mm revolution i.d. mm revolution 0.13 0.0014 1.14 0.09 0.19 0.0028 1.22 0.10 0.25 0.0048 1.30 0.11 0.38 0.011 1.42 0.13 0.44 0.014 1.52 0.15 0.51 0.019 1.65 0.17 0.57 0.024 1.75 0.19 0.64 0.030 1.85 0.21 0.76 0.042 2.06 0.25 0.89 0.057 2.29 0.29 0.95 0.064 2.54 0.33 1.02 0.073 2.79 0.37 1.09 0.083 3.17 0.431) Water, Tygon® tubing, without differential pressure

k Calculation example for fl ow rate rpm x ml per revolution = ml/min 100 x 0.43 = 43

Ask for the ISMATEC® Pump Tubing Selection Guide.

Nominal voltage Type REGLO-E MS/CA5-06 Order No. 12 VDC IS 3184

Ordering information

Please note

Specifi cations valid for the followingISMATEC® control units:a) REGLO-E Analog - see data sheet 08.1b) REGLO-E Digital - see data sheet 08.2

*