Flexible Cables, PVC And Rubber Temperature limits: -5 to +70°C flexing. -20 to +70°C fixed. *Bending radius: Static - 6 x overall diameter. Flexing - 15 x overall diameter. Core identification: 2 core - Black with White numbers. 3 core and above - Black with White numbers plus Green/Yellow. Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. 7 core - Blue, Brown, Black, Grey, White, Red, Green/Yellow. Should not be installed at temperatures below -5°C. TYPE YY CONTROL CABLES Plain annealed flexible copper conductors, PVC insulated, PVC sheathed. Grey. 300/500 volts grade, generally to BS6500 and VDE 0250. CCC Conductor Stranding No. Of Weight Overall Gland Code Size (mm) Cores (Kg/Km) Diameter Size (mm 2 ) (mm) (mm) YY2X/75 0.75 24/0.20 2 46 5.60 20/16 YY3X/75 0.75 24/0.20 3 52 5.70 20/16 YY4X/75 0.75 24/0.20 4 64 6.20 20/16 YY5X/75 0.75 24/0.20 5 77 7.00 20/16 YY7X/75 0.75 24/0.20 7 95 7.30 20/16 YY12X/75 0.75 24/0.20 12 155 9.50 20S YY18X/75 0.75 24/0.20 18 221 11.10 20 YY25X/75 0.75 24/0.20 25 305 13.20 20 YY34X/75 0.75 24/0.20 34 460 16.70 25 YY50X/75 0.75 24/0.20 50 578 18.40 25 YY65X/75 0.75 24/0.20 65 850 23.50 32 YY2X1 1 32/0.20 2 55 6.00 20/16 YY3X1 1 32/0.20 3 66 6.10 20/16 YY4X1 1 32/0.20 4 82 6.70 20/16 YY5X1 1 32/0.20 5 93 7.50 20/16 YY7X1 1 32/0.20 7 121 8.10 20S YY12X1 1 32/0.20 12 200 11.00 20S YY18X1 1 32/0.20 18 318 12.70 20 YY25X1 1 32/0.20 25 415 15.50 25 YY34X1 1 32/0.20 34 575 18.30 25 YY41X1 1 32/0.20 41 665 19.00 25 YY50X1 1 32/0.20 50 815 21.30 32 YY65X1 1.0 32/0.20 65 1055 25.60 32 YY2X1/5 1.5 30/0.25 2 69 6.60 20/16 YY3X1/5 1.5 30/0.25 3 87 7.00 20/16 YY4X1/5 1.5 30/0.25 4 110 7.60 20/16 YY5X1/5 1.5 30/0.25 5 124 8.10 20S YY7X1/5 1.5 30/0.25 7 176 9.20 20S YY8X1/5 1.5 30/0.25 8 230 11.20 20 YY10X1/5 1.5 30/0.25 10 265 12.40 20 YY12X1/5 1.5 30/0.25 12 290 13.10 20 YY18X1/5 1.5 30/0.25 18 424 14.80 25 YY25X1/5 1.5 30/0.25 25 565 18.00 25 YY34X1/5 1.5 30/0.25 34 775 21.00 32 YY50X1/5 1.5 30/0.25 50 1095 24.20 32 YY65X1/5 1.5 30/0.25 65 1390 28.80 40 57 * All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. CCC2016A5Artwork.qxp_Layout 1 23/10/2017 19:24 Page 57

Upload: lexuyen

Post on 20-May-2018

212 views

Category:

Documents


0 download

TRANSCRIPT

Flexible Cables, PVC And Rubber

Temperature limits:-5 to +70°C flexing.-20 to +70°C fixed.

*Bending radius:Static - 6 x overall diameter.Flexing - 15 x overall diameter.

Core identification:2 core - Black with Whitenumbers.3 core and above - Black with White numbers plusGreen/Yellow.

Also available with colouredcores as follows:2 core - Blue, Brown.3 core - Blue, Brown,Green/Yellow.4 core - brown, black, grey,green/yellow.5 core - Blue, Brown, Black,Grey, Green/Yellow.7 core - Blue, Brown, Black,Grey, White, Red, Green/Yellow.

Should not be installed attemperatures below -5°C.

TYPE YY CONTROL CABLESPlain annealed flexible copper conductors, PVC insulated, PVC sheathed.Grey. 300/500 volts grade, generally to BS6500 and VDE 0250.

CCC Conductor Stranding No. Of Weight Overall Gland Code Size (mm) Cores (Kg/Km) Diameter Size (mm2) (mm) (mm) YY2X/75 0.75 24/0.20 2 46 5.60 20/16 YY3X/75 0.75 24/0.20 3 52 5.70 20/16 YY4X/75 0.75 24/0.20 4 64 6.20 20/16 YY5X/75 0.75 24/0.20 5 77 7.00 20/16 YY7X/75 0.75 24/0.20 7 95 7.30 20/16 YY12X/75 0.75 24/0.20 12 155 9.50 20S YY18X/75 0.75 24/0.20 18 221 11.10 20 YY25X/75 0.75 24/0.20 25 305 13.20 20 YY34X/75 0.75 24/0.20 34 460 16.70 25 YY50X/75 0.75 24/0.20 50 578 18.40 25 YY65X/75 0.75 24/0.20 65 850 23.50 32 YY2X1 1 32/0.20 2 55 6.00 20/16 YY3X1 1 32/0.20 3 66 6.10 20/16 YY4X1 1 32/0.20 4 82 6.70 20/16 YY5X1 1 32/0.20 5 93 7.50 20/16 YY7X1 1 32/0.20 7 121 8.10 20S YY12X1 1 32/0.20 12 200 11.00 20S YY18X1 1 32/0.20 18 318 12.70 20 YY25X1 1 32/0.20 25 415 15.50 25 YY34X1 1 32/0.20 34 575 18.30 25 YY41X1 1 32/0.20 41 665 19.00 25 YY50X1 1 32/0.20 50 815 21.30 32 YY65X1 1.0 32/0.20 65 1055 25.60 32 YY2X1/5 1.5 30/0.25 2 69 6.60 20/16 YY3X1/5 1.5 30/0.25 3 87 7.00 20/16 YY4X1/5 1.5 30/0.25 4 110 7.60 20/16 YY5X1/5 1.5 30/0.25 5 124 8.10 20S YY7X1/5 1.5 30/0.25 7 176 9.20 20S YY8X1/5 1.5 30/0.25 8 230 11.20 20 YY10X1/5 1.5 30/0.25 10 265 12.40 20 YY12X1/5 1.5 30/0.25 12 290 13.10 20 YY18X1/5 1.5 30/0.25 18 424 14.80 25 YY25X1/5 1.5 30/0.25 25 565 18.00 25 YY34X1/5 1.5 30/0.25 34 775 21.00 32 YY50X1/5 1.5 30/0.25 50 1095 24.20 32 YY65X1/5 1.5 30/0.25 65 1390 28.80 40

57*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius(MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities oftheir cable, it is not a specification defined in standards.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.