uc santa cruz standard plaster installation and details severe … · 2020-03-18 · standard...

81
CAMPUS STANDARDS APPENDIX I UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014

Upload: others

Post on 16-May-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

CAMPUS STANDARDS APPENDIX I

UC SANTA CRUZ

STANDARD PLASTER INSTALLATION AND DETAILS

SEVERE WEATHER

February 21, 2014

Page 2: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 1 of 13

WINDOW INSTALLATION SEQUENCING GUIDE

Issued By:

Pyatok Architects and Allana Buick & Bers Inc.

Issue Date:

02/21/14

These documents must be printed in COLOR

Notes:

1. Details and photos show the windows at Kresge only. Sequencing is identical for the Stevenson windows, but refer to ASI 016 (01/03/14) and ASI 016-R1 (01/17/14) for details of the Stevenson windows.

2. Any conditions that do not allow the installation to be performed as outlined in this guide require immediate notification of the Architect.

3. Where elements on details and instructions are noted to be “soldered”. Elements are to be “soldered water-tight”, not just “spot” or “tack” soldered.

Page 3: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 2 of 13

Window Sill Detail (Detail 1/AK9.01A)

The rough opening is prepared by applying the Air & Water Barrier min. 3

inches into the rough opening.

Apply primer in raw wood surfaces in rough opening

to receive SAF.

Page 4: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 3 of 13

ALL SAF installed to roll flat with J-Roller.

SAF corner pieces installed at bottom corners 4” up

jambs.

Page 5: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 4 of 13

GSM angle along sill butted up to tapered shim and

secured with “S.S. Pan-Head screws” or “hot-dip

galvanized ring-shanks nails” to sill.

SAF butterfly patches installed at sill GSM angle to

jamb intersections.

Page 6: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 5 of 13

12” wide SAF installed min. 4” over sheathing face, onto

the GSM angle to interior edge of sill R.O.

SAF butterflies installed at outside framing corners of

sill.

Page 7: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 6 of 13

Window Jamb Detail (Detail 2/AK9.01A)

12” wide SAF installed along jamb over

sheathing face 4” and extending 4” beyond

rough opening @ top & bottom.

Page 8: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 7 of 13

SAF butterfly patches installed at jamb to

head framing outside corners.

Window Head Detail (Detail 3/AK9.01A)

Page 9: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 8 of 13

9” wide SAF installed over window head and extended

to outside edge of jamb SAF.

Apply continuous bead of Silicone sealant at window

head and jamb sides.

Do not apply sealant along sill.

Page 10: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 9 of 13

Window installed into rough opening into continuous

bead of sealant along head and jambs. Fasten with “S.S.

Pan-Head Screws”.

Note: Install window shims as necessary. Use “1/16 inch

drain mesh” shims.

Horseshoe Shims or 1/16 inch plastic drainage shims

installed along sill flange are acceptable.

Note: If drainage shims used do not extend past window

frame width.

IMPORTANT:

STOP HERE AND WAIT FOR SEALANT TO CURE BEFORE PROCEEDING!!!

Page 11: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 10 of 13

9” wide SAF installed over window flange jambs,

extended 6” beyond sill & head rough openings

9” wide SAF installed over window head, extended to outside edge of jamb SAF.

Page 12: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 11 of 13

GSM head flashing installed over window head. Fasten

using “S.S. Pan-Head Screws” or “hot-dip

galvanized ring-shank nails”.

9” wide SAF installed over GSM head flashing.

Page 13: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 12 of 13

Dress top edge of head flashing with continuous bead of silicone sealant.

Provide backer rod in void between window frame and

R.O. @ jambs and head (Interior Side).

Use appropriate size backer

rod. Do not braid multiple rods together to fill wider

gap.

Page 14: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 13 of 13

Install GSM angles along jambs, set in a full-bed of

sealant. (Interior Side)

Provide sealant joint between window assembly and angle along sill, jambs,

and header. (Interior Side)

Page 15: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 1 of 11

DOOR INSTALLATION SEQUENCING GUIDE

Issued By:

Pyatok Architects and Allana Buick & Bers Inc.

Issue Date:

02/21/14

These documents must be printed in COLOR

Notes:

1. Details and photos show an out-swinging door. Sequencing is identical for in-swinging doors.

2. Any conditions that do not allow the installation to be performed as outlined in this guide require immediate notification of the Architect.

3. Where elements on details and instructions are noted to be “soldered”. Elements are to be “soldered water-tight”, not just “spot” or “tack” soldered.

Page 16: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 2 of 11

Door Threshold @ Landing

(Detail 3/AS9.10)

Sealant applied

along door sill and

wall flanges.

Page 17: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 3 of 11

Fully soldered GSM sill pan set in full bed of sealant under sill

and wall flanges. Sill pan to be set in

recessed nailer, see detail (not shown in

mockup photo)

Apply hot-dip galvanized ring-

shank nail fasteners along vertical surfaces only.

Confirm podium waterproofing

installed onto door sill pan and up jambs prior to door frame

installation.

Page 18: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 4 of 11

Remove flange from bottom corners of door frame jambs prior to setting into

rough opening.

ALL SAF installed to roll flat with J-Roller.

Page 19: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 5 of 11

Exterior Door Jamb (Detail 2/AK9.10A)

Install SAF along door jambs and 3” onto header rough

opening.

Note: If Air and Water Barrier is

applied onto full face of Jamb R.O. SAF

can be omitted.

Page 20: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 6 of 11

Exterior Door Head (Detail 1/AK9.10A)

12” wide SAF installed into full length of rough

opening extending out over sheathing 4”

Page 21: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 7 of 11

Door frame set into rough opening and secured to structure

with “pan-head screws” or “hot-dip

galvanized ring-shank nails.

24 GA GSM L-Metal installed, with

minimum 1/4” contact between L-Metal and Door Frame, set in

sealant.

Page 22: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 8 of 11

6” wide SAF installed over L-Metal and

under plaster stop.

NOTE: GSM Drip to be installed prior to installation of SAF

over L-metal.

GSM head flashing installed, head

flashing to overhang over door frame.

Page 23: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 9 of 11

Plaster stop/J-mold installed, butted up to GSM head flashing.

Note: Plaster stop in-line with head

flashing end dams.

Page 24: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 10 of 11

6” wide SAF installed over plaster stop

flange and extended over head flashing flange along jambs.

9” wide SAF installed over window head

flashing.

Page 25: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 11 of 11

Dress top edge of horizontal seam with continuous bead of

silicone sealant.

Page 26: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 1 of 11  

PODIUM/LANDING INSTALLATION SEQUENCING GUIDE 

Issued By:

Pyatok Architects and Allana Buick & Bers Inc.

Issue Date:

02/21/14

These documents must be printed in COLOR

Notes:

1. In the field, the landings are a concrete slab, not the wood frame shown in the mockup photos. Proper prepping and verifying slab slope away from the building will be required on site.

2. Any conditions that do not allow the installation to be performed as outlined in this guide require immediate notification of the Architect.

3. Where elements on details and instructions are noted to be “soldered”. Elements are to be “soldered water-tight”, not just “spot” or “tack” soldered.

 

Page 27: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 2 of 11  

Podium WP Typical Wall @ Landing (Detail 2/AK8.21)

Prior to installation of podium WP

confirm preceding installations

complete (i.e. sheet metal saddles, door sill pans, continuous wall flashing, etc).

Page 28: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 3 of 11  

Clean the substrate(s) to receive podium

waterproofing before proceeding with application of

podium WP system.

PRIMER is to be applied onto ALL

substrates receiving the podium WP

membrane.

Page 29: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 4 of 11  

Tape podium waterproofing edge line. Waterproofing

to extend up to edge of Air & Water

Barrier.

1st Coat of podium waterproofing

applied (approx. 90 mils).

Page 30: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 5 of 11  

Podium WP @ Door Threshold

Following the

application of 1st coat of the WP

membrane install the uncured

neoprene onto the door sill pan.

Note: Do not apply neoprene @ face of jamb R.O. & feather WP membrane to minimize build-up

Podium WP @ Typ. Base Flashing

Condition

Uncured neoprene applied following

application of the 1st coat of WP membrane.

Page 31: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 6 of 11  

Podium WP @ Deck Edge at Landing (Detail 1/AK8.21)

Apply 1st coat of WP onto deck edge and place ½ the width of

the uncured neoprene onto

horizontal surface of edge and allowing min 3” of neoprene

onto vertical surface.

Page 32: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 7 of 11  

Apply a bonding adhesive (sealant) onto the vertical

surface of the deck edge to receive the uncured neoprene

“Pig Ear” the corners of the overhanging

neoprene. Do not slice neoprene at outside corners.

Page 33: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 8 of 11  

Apply WP membrane over

uncured neoprene over deck edge.

Set 24 GA S.S.

Edge Metal into WP membrane and

fasten as required.

Note: Apply PRIMER onto S.S.

edge metal on surfaces to come in

contact with WP membrane (top and bottom of horizontal leg of edge metal).

Page 34: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 9 of 11  

Clean surface edge metal to receive

podium WP prior to application.

Field Application of Podium WP

Following

completion of WP detailing (i.e. base

flashings, deck edges, saddles,

etc.)

Apply 1st coat of podium WP (min. 90

mils)

Page 35: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 10 of 11  

2nd Coat of podium waterproofing

applied (approx. 125 mils) onto

reinforcing fabric.

Note: Feather podium WP at door

jambs and sheathing face area

for door frame to prevent build-up.

Apply protection course over 2nd Coat

of podium WP.

Note: For critical build-up areas only provide 1-layer of protection coarse

(i.e. door jambs, lath accessories, etc)

IMPORTANT:

Perform Manufacturer’s required testing

prior to installations of

drain mat & concrete

overburden

Page 36: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 11 of 11  

Install UV metal counter flashing with

hemmed edge on bottom of leg and

fasten with “stainless steel pan-

head screws” or “hot-dip galvanized ring-shank nails”.

 

Page 37: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 1 of 26  

LATH & PLASTER/WALL PENETRATION INSTALLATION SEQUENCING GUIDE 

Issued By:

Pyatok Architects and Allana Buick & Bers Inc.

Issue Date:

02/21/14

These documents must be printed in COLOR

Notes:

1. This document describes the installation for the plaster accessories, waterproofing for the electrical boxe penetrations, pipe penetrations, wall cap vents, louver vents, and scaffold tie-backs.

2. In the field, the landings are a concrete slab, not the wood frame shown in the mockup photos. Proper prepping and verifying slab slope away from the building will be required on site.

3. Any conditions that do not allow the installation to be performed as outlined in this guide require immediate notification of the Architect.

4. Where elements on details and instructions are noted to be “soldered”. Elements are to be “soldered water-tight”, not just “spot” or “tack” soldered.

 

Page 38: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 2 of 26  

Base of Wall (Detail 3/AK8.01A)

Install GSM Drip Edge at Base of Wall onto substrate coated

with Air & Water barrier with “S.S.

Pan-Head screws” or “hot-dip galvanized ring-shank nails”.

Note: Mitered joints to be set in a full bed of sealant 2” wide filling

back of profile.

Page 39: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 3 of 26  

ALL SAF installed to roll flat with J-Roller.

Install 9” wide SAF lapped over top leg of

GSM Drip Edge.

Page 40: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 4 of 26  

Dress top edge of SAF with continuous

bead of silicone sealant.

Install 9” wide SAF onto substrate at

locations where lath accessories are to be installed (i.e. control joints, corner aids,

inside corners, etc.)

Page 41: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 5 of 26  

Scaffolding Bolt WP (Detail 10/AK8.01)

Apply SAF “sill” at bolt onto sheathing

with Air & Water Barrier (Step 2)

Page 42: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 6 of 26  

Apply second piece of SAF “head” at bolt, staggered vertically

3” (Step 3)

Apply sealant along top edge of SAF and

all around bolt (Step 4)

Page 43: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 7 of 26  

Electrical Wall Penetration

(Detail 2/AK8.02)

Install S.S. flashing around electrical box, and fasten with “S.S. Pan-Head screws” or “hot-dip galvanized nails” as required.

Note: Plaster stop

around electrical box flashing to be continuous.

Page 44: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 8 of 26  

Install 9” wide SAF alongside flanges of

electrical box flashing.

Apply SAF along top flange of electrical

box flashing.

Page 45: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 9 of 26  

Dress top edge of SAF with continuous

bead of sealant to seal horizontal seam.

Fabricated Penetration Flashing (Detail 12/AK8.01)

Page 46: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 10 of 26  

Install 1-piece or 2-piece (for 2-piece flashing, provide

sealant at lap seams) and fasten to

substrate as required.

Note: Provide sufficient gap

between flange and pipe to allow for backer rod and sealant or non-

expanding foam.

Step 1: Install 9” wide SAF along side

flanges

Step 2: Install 9” wide SAF along top flange

Step 3: Dress top edge of SAF with

continuous bead of sealant to seal

horizontal seam.

Page 47: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 11 of 26  

Make-Up Air Wall Cap Termination (Detail 2/AK8.61)

Install fully-soldered wall cap with insect

screen into R.O. coated with Air &

Water Barrier 3” into opening and fasten with “S.S. Pan-Head screws” or “hot-dip

galvanized ring-shank nails”.

Note: Plaster stop around wall cap flashing to be continuous.

Page 48: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 12 of 26  

Install 9” wide SAF along jambs of wall

cap flanges

Install 9” wide SAF along top flange of

wall cap

Page 49: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 13 of 26  

Dress top edge of SAF with continuous

bead of sealant to seal horizontal seam

Louver Flashing Sequence Diagram (Detail 4/AK9.02)

Page 50: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 14 of 26  

Louver Sill Detail (Detail 1/AK9.02)

The rough opening is prepared by applying

the Air & Water Barrier min. 3 inches

into the R.O.

Apply primer on raw wood surfaces in

R.O. to receive SAF.

Page 51: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 15 of 26  

No Photo (Similar to window installation, but without sloping shim)

SAF corner pieces installed at bottom

corners 4” up jambs.

 

Install GSM angle along sill. Set in

sealant and fasten with “S.S. pan-head Screws” or “hot-dip galvanized nails”

placed approximately within 3/8” from

interior face of louver.

Page 52: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 16 of 26  

SAF butterfly patches installed at sill GSM

angle to jamb intersections.

(Photo from window installation, but can be applied to louver

installation)

Install 12” wide SAF min. 4” over

sheathing face, onto the GSM angle to interior edge of sill

R.O.

(Photo from window installation, but can be applied to louver

installation)

Page 53: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 17 of 26  

SAF butterflies installed at outside framing corners of

sill.

(Photo from window installation, but can be applied to louver

installation)

  

 

Louver Jamb Detail (Detail 2/AK9.02)

Page 54: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 18 of 26  

Install 6” wide SAF installed along full face of jamb and

head rough opening if Air & Water Barrier

has not been applied over full depth of rough opening.

Install fully-soldered GSM collar flashing

around opening. Fasten with “S.S.

pan-head screws” or “hot-dip galvanized

nails”.

Page 55: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 19 of 26  

6” wide SAF at jams, over collar flashing extended 6” beyond

sill & head rough openings.

  

 

Louver Head Detail (Detail 2/AK9.02)

Page 56: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 20 of 26  

6” wide SAF installed over window head, extended to outside edge of jamb SAF.

GSM head flashing installed over the

louver head, fasten with “S.S. pan-head screws” or “hot-dip galvanized nails”.

Page 57: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 21 of 26  

9” wide SAF installed over GSM head

flashing

No Photo

Dress top edge of head flashing with continuous bead of

silicone sealant.

Page 58: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 22 of 26  

Install louver into rough opening and set in sealant along

sill angle.

Install GSM angle along jambs & header

into louver, set in a bed of sealant,

fastened with “S.S. pan-head screws”.

Note: Where

opening is not accessible from the

interior, install angles before

louver

Page 59: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 23 of 26  

Fasten louver to angle, from front or back as required by

manufacturer. Provide sealant joint

between louver assembly and angle

along jambs and header (interior side).

Apply backer rod and sealant between louver and collar

flashing around sill and jam.

Apply sealant

between louver and head flashing

Page 60: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 24 of 26  

Base of Wall (Detail 3/AK8.01A)

Installation of drain mat fastened to

substrate with staples and nails where

necessary

IMPORTANT: Fasten ALL

accessories to sheathing PRIOR to

lath.

Page 61: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 25 of 26  

Drainage layer geotextile fabric to be lapped over seams.

Stucco stop with no weep holes fastened over drainage layer at

base of wall.

Page 62: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

Page 26 of 26  

Control joint accessories fastened prior to installation of

lath

Lath fastened a minimum of 6” o.c.

with grip-rite fastener, and minimum 3” minimum lap at

edges.

 

Page 63: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

1611 Telegraph Avenue | Suite 200 | Oakland, CA 94612 | p:510-465-7010 f:510-465-8575 | www.pyatok.com

Architect’s Supplemental Instructions No. 035 Mockup Manual Installation Guides_DETAILS

PROJECT: UC, Santa Cruz Infill Apartment Repairs Santa Cruz, CA 95064 Project No. 1652

ARCHITECT’S SUPPLEMENTAL INSTRUCTION NO: 035 Mockup Manual Installation Guides_DETAILS

OWNER: UC, Santa Cruz Physical Planning & Construction 1156 High Street, Barn G Santa Cruz, CA 95064

DATE OF ISSUANCE: 02/21/14

CONTRACT FOR: Phase 1

FROM ARCHITECT: Pyatok Architects, Inc. 1611 Telegraph Ave., #200 Oakland, CA 94612

CONTRACT DATE: Amendment 2: 9/3/13

TO CONTRACTOR: Blach Construction Company 469 El Camino Real, Suite 100 Santa Clara, CA 95050

ARCHITECT’S PROJECT NUMBER: 1308

The Work shall be carried out in accordance with the following supplemental instructions issued in accordance with the Contract Documents without change in the Contract Sum or Contract Time. Proceeding with the Work in accordance with these instructions indicates your acknowledgement that there will be no change in Contract Sum or Contract Time. DESCRIPTION: Attached are the revised and new details associated with the Mockup Manual Installation Guides that were never issued through an official ASI. Please use these details to replace any preexisting details. Below is a list of the details attached, the details that were revised through a separate ASI (reference ASI noted), and the details that did not require revisions. Revisions bubbled in red on detail sheets. ATTACHMENTS (REVISED DETAILS):

1. ASK 2.06R1 – Kresge Window Sill Detail (1/AK9.01A) 2. ASK 2.07R2 – Kresge Window Jam Detail (2/AK9.01A) 3. ASK 2.08R2 – Kresge Window Head Detail (3/AK9.01A) 4. ASK 2.09R1 – Stevenson Window Sill Detail (1/AS9.01A) 5. ASK 2.10R1 – Stevenson Window Jam Detail (2/AS9.01A) 6. ASK 2.11R1 – Stevenson Window Head Detail (3/AS9.01A) 7. ASK 2.13R1 – Louver Sill Detail (1/AK9.02, 1/AS9.02) 8. ASK 2.14R1 – Louver Jamb Detail (2/AK9.02, 2/AS9.02) 9. ASK 2.15R1 – Louver Head Detail (3/AK9.02, 3/AS9.02) 10. ASK 2.16R1 – Exterior Door Head (1/AK9.10A, 1/AS9.10A) 11. ASK 2.17R1 – Exterior Door Jamb (2/AK9.10A, 2/AS9.10A) 12. ASK 2.18R1 – Exterior Door Threshold at Landing (3/AK9.10A, 3/AS9.10A)

OWNER:

ARCHITECT:

CONSULTANT:

CONTRACTOR:

FIELD:

Via e-mail

Page 64: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

1611 Telegraph Avenue | Suite 200 | Oakland, CA 94612 | p:510-465-7010 f:510-465-8575 | www.pyatok.com

13. ASK 2.20R1 – Scaffolding Bolt Waterproofing Diagram (10/AS8.01, 10/AS8.01) 14. ASK 2.21 – GSM Door Pan Flashing (4/AS9.10, 4/AK9.10) 15. ASK 2.22 – Enlarged Wall at Landing (10/AS8.21, 10/AK8.21) 16. ASK 2.23 – Enlarged Deck Edge Detail (9/AS8.21, 9/AK8.21) (NOT REVISED, BUT INCLUDED AS PART OF

MOCKUP MANUAL) 17. ASK 2.24 – Fabricated Penetration Flashing (12/AK8.01, 12/AS8.01)

REVISED DETAILS ISSUED THROUGH SEPARATE ASI’S:

1. ASI 018 a. ASK 5.01 – b. ASK 5.02 – c. ASK 5.02 –

2. ASI 028 a. ASK 2.03R1 -

DETAILS THAT DID NOT REQUIRE REVISION:

1. ASI 016 a. ASK 2.01 – b. ASK 2.12 – Louver Flashing & Sequence Diagram

ISSUED BY THE ARCHITECT:

Curtis M. Caton Jr., AIA, Principal _____________________________________ ________________________________________________ (Signature) (Printed Name and Title)

Page 65: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

3/4" VERT. LEG x 1" 24 GAGSM ANGLE

3/4" THICK WD. WINDOW SILL, BACKPRIME

1/2" WD. WINDOW APRON

CONT. SLOPED SHIM

1/16" HORSESHOE SHIM AT+/- 12" O.C.

ALUMINUM WINDOW, SEESPECIFICATIONS

CONT. SEALANT BEAD

SAF, WRAPPED UP ONTO ANGLEAND FULL DEPTH OF R.O.

SEALANT

(EXISTING STRUCTURE)DRAINAGE LAYER

AIR AND WATER BARRIER,CONT. ONTO SHIM

1/2"

SHADE

1/8" GAP FROM WINDOWTO ANGLE. (MAX. 3/16")

GYP. BD. PATCHAS REQ'D.

REF. DWG:

SCALE:

TITLE: DWG. NO:

ATTACHED TO:

DATE:

1611 Telegraph Avenue, Suite 200Oakland, California 94612

510.465.7010 p | 510.465.8575 fwww.pyatok.com

6" = 1'-0"

2/21/2014 5:58:06 PM

01/17/14 ASK2.06-R1

KRESGE - WINDOW SILL DETAIL

U.C. SANTA CRUZ INFILL APARTMENTSREPAIRS 1/AK9.01A

Page 66: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

+/- 1/4" WIDE JOINT W/SEALANT

12" SAF, LAP O/ WINDOW FIN

SAF, CONT. INTO FULL DEPTH OFROUGH OPENING

CEMENT PLASTER

1"X1", 24 GA GSM ANGLE W/HEMMED EDGE. SET IN A FULLBED OF SEALANT O/ SAF ANDFASTEN @ 12" O.C., MIN.

SET HEAD AND JAMB FLANGES IN SEALANT

ALUMINUM WINDOW, SEESPECIFICATIONS

GYP. BD. WINDOW WRAP

5/8" SHIM

(EXISTING STRUCTURE)

DRAINAGE LAYER

AIR AND WATER BARRIER,CONT. MIN. 3" INTO ROUGHOPENING

~ 1

3/16

"

SHADE OVERLAP PAST JAMB, TYP.

2"

SHADE5/8"

1/4"

L-METAL

MIN. SPACE REQ'D FROMG.S.M. ANGLE TO F.O.GYP. BD.

BACKER ROD

REF. DWG:

SCALE:

TITLE: DWG. NO:

ATTACHED TO:

DATE:

1611 Telegraph Avenue, Suite 200Oakland, California 94612

510.465.7010 p | 510.465.8575 fwww.pyatok.com

6" = 1'-0"

2/21/2014 6:00:12 PM

02/13/14 ASK2.07-R2

KRESGE - WINDOW JAMB DETAIL

U.C. SANTA CRUZ INFILL APARTMENTSREPAIRS 2/AK9.01A

Page 67: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

12" SAF, EXTEND O/ HEAD FLASHINGS

GSM HEAD FLASHING (PAINT)W/ END CLOSURE AND END DAMS.EXTEND UP WALL 4" MIN.

ALUMINUM WINDOW, SEESPECIFICATIONS

9" SAF, LAP O/ WINDOW FIN

+/- 1/4" JOINT W/ SEALANT

L-METAL, TYP.

GYP. BD. WINDOW WRAP

12" SAF, RUN CONT. INTO FULLDEPTH OF ROUGH OPENING

CEMENT PLASTER

SET HEAD AND JAMB FLANGES IN SEALANT

(EXISTING STRUCTURE)

SEALANT FILLET

DRAINAGE LAYER

AIR AND WATER BARRIER,CONT. MIN. 3" INTO ROUGHOPENING

~ 3 9/16"

BLACKOUTWINDOW SHADEUNIT

1-1/8" X 3-1/2"CONTINUOUS PAINTEDBLOCKING

SHADE

1 1/8"

DRESS EDGE W/ SEALANT TOSEAL HORIZ. SEAM ABOVE(NOT SHOWN)

BACKER ROD

REF. DWG:

SCALE:

TITLE: DWG. NO:

ATTACHED TO:

DATE:

1611 Telegraph Avenue, Suite 200Oakland, California 94612

510.465.7010 p | 510.465.8575 fwww.pyatok.com

6" = 1'-0"

2/21/2014 6:02:09 PM

02/13/14

ASK 2.08-R2KRESGE - WINDOW HEAD DETAIL

U.C. SANTA CRUZ INFILL APARTMENTS REPAIRS3/AK9.01A

Page 68: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

3/4" VERT. LEG x 1" 24 GAGSM ANGLE

3/4" WD. WINDOW SILL

1/2"

1/2" WD. WINDOW APRON

ALUMINUM WINDOW,SEE SPECIFICATIONS

CONT. SEALANT BEAD

SEALANT

(EXISTING STRUCTURE)

1/16" HORSESHOE SHIM AT +/-12" O.C.

SAF, WRAPPED UP ONTO ANGLEAND FULL DEPTH OF R.O.

DRAINAGE LAYER

AIR AND WATER BARRIER,CONT. ONTO SHIM

CONTINUOUS SLOPED SHIM

~ 2 11/16"

SHADE

GYP. BD. PATCHAS REQ'D.

1/8" GAP FROM WINDOWTO ANGLE. (MAX. 3/16")

REF. DWG:

SCALE:

TITLE: DWG. NO:

ATTACHED TO:

DATE:

1611 Telegraph Avenue, Suite 200Oakland, California 94612

510.465.7010 p | 510.465.8575 fwww.pyatok.com

6" = 1'-0"

2/21/2014 6:23:25 PM

02/21/14 ASK2.09-R1

STEVENSON - WINDOW SILL DETAIL

U.C. SANTA CRUZ INFILL APARTMENTSREPAIRS 1/AS9.01A

Page 69: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

SAF, CONT. INTOFULL DEPTH OFROUGH OPENING

ALUMINUM WINDOW,SEE SPECIFICATIONS

GYP. BD.WINDOW WRAP

(EXISTING STRUCTURE)

+/- 1/4" WIDE JOINT W/SEALANT

1"X1", 24 GA GSM ANGLEW/ HEMMED EDGE. SETIN A FULL BED OFSEALANT O/ SAF ANDFASTEN @ 12" O.C., MIN.

12" SAF, LAP O/ WINDOW FIN

CEMENT PLASTER

SET HEAD AND JAMB FLANGES IN SEALANT

DRAINAGE LAYER

AIR AND WATER BARRIER, CONT. MIN. 3"INTO ROUGH OPENING.

5/8” SHIM

~ 2

11/1

6"

SHADE OVERLAP PAST JAMB, TYP.

3 1/2"

SHADE

L-METAL

1/4"MIN. SPACE REQ'DFROM G.S.M. ANGLETO F.O. GYP. BD.

REF. DWG:

SCALE:

TITLE: DWG. NO:

ATTACHED TO:

DATE:

1611 Telegraph Avenue, Suite 200Oakland, California 94612

510.465.7010 p | 510.465.8575 fwww.pyatok.com

6" = 1'-0"

2/21/2014 6:18:48 PM

02/21/14 ASK2.10-R1

STEVENSON - WINDOW JAMB DETAIL

U.C. SANTA CRUZ INFILL APARTMENTSREPAIRS 2/AS9.01A

Page 70: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

ALUMINUM WINDOW,SEE SPECIFICATIONS

+/- 1/4" JOINT WITH SEALANT

L-METAL, TYP.

GYP. BD. WINDOW WRAP

(EXISTING STRUCTURE)

SET HEAD AND JAMB FLANGES IN SEALANT

SEALANT FILLET

12" SAF, EXTEND O/ HEAD FLASHINGS

GSM HEAD FLASHING (PAINT)W/ END CLOSURE AND END DAMS.EXTEND UP WALL 4" MIN.

9" SAF, LAP O/ WINDOW FIN

12" SAF, CONT. INTO FULL DEPTHOF ROUGH OPENING

CEMENT PLASTER

DRAINAGE LAYER

AIR AND WATER BARRIER,CONT. MIN. 3" INTO ROUGHOPENING.

5 1/16"

BLACKOUTWINDOW SHADEUNIT

2-3/8" X 3-1/2"CONTINUOUS PAINTEDBLOCKING

SHADE

2 5/8"

DRESS EDGE W/ SEALANT TOSEAL HORIZ. SEAM ABOVE(NOT SHOWN)

BACKER ROD

REF. DWG:

SCALE:

TITLE: DWG. NO:

ATTACHED TO:

DATE:

1611 Telegraph Avenue, Suite 200Oakland, California 94612

510.465.7010 p | 510.465.8575 fwww.pyatok.com

6" = 1'-0"

2/21/2014 6:17:03 PM

02/21/14

ASK 2.11-R1STEVENSON - WINDOW HEAD DETAIL

U.C. SANTA CRUZ INFILL APARTMENTS REPAIRS3/AS9.01A

Page 71: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

INSECT SCREEN

CONT. 1" x 1" GSM L ANGLE. HEMVERTICAL EDGE. SET IN FULL

BED OF SEALANT CONT.AROUND OPENING.

FASTEN ANGLE TO FRAMING

(EXISTING STRUCTURE)

AIR AND WATER BARRIER. CONT.MIN. 3" INTO R.O.

12" S.A.F., WRAP UP OVERINSTALLATION ANGLE AND INTOFULL DEPTH OF R.O.

PLYWOOD SHEATHING

SEALANT AND BACKER ROD

FASTENER

CEMENT PLASTER W/ METALLATH

FULLY SOLDERED FOUR SIDEDGSM COLLAR FLASHING, 4"FLANGE

REPAIR GYP. BD. FINISHWHERE OCCURS

SECURE LOUVER TO ANGLE IN AFULL BED OF SEALANT

INSTALLATION ANGLE AT JAMBS(BEYOND). SEE DETAIL

DRAINAGE LAYER

SHIM

LOUVER

3/8"

GSM COLLAR FLASHINGBEYOND

REF. DWG:

SCALE:

TITLE: DWG. NO:

ATTACHED TO:

DATE:

1611 Telegraph Avenue, Suite 200Oakland, California 94612

510.465.7010 p | 510.465.8575 fwww.pyatok.com

6" = 1'-0"

2/21/2014 6:15:08 PM

01/28/14 ASK2.13R1

LOUVER SILL DETAIL

U.C. SANTA CRUZ INFILL APARTMENTSREPAIRS 1/AK9.02 & 1/AS9.02

Page 72: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

INSECT SCREEN

CONT. 1" x 1" GSM L ANGLE. SETIN FULL BED OF SEALANT

CONTINUOUS AROUND OPENING.

FASTEN ANGLE TO FRAMING

(EXISTING STRUCTURE)

AIR AND WATER BARRIER.CONT. MIN. 3" INTO R.O.

PLYWOODSHEATHING

SEALANT ANDBACKER ROD

FASTENER

CEMENT PLASTER W/METAL LATH FULLY SOLDERED FOUR

SIDED GSM COLLARFLASHING, 4" FLANGE

REPAIR GYP. BD. FINISH

FASTEN LOUVER TO ANGLE, FROMFRONT OR BACK AS REQ'D BY

MANUFACTURER. SET IN SEALANT

INSTALLATION ANGLE AT BASE(BEYOND). SEE DETAIL

DRAINAGE LAYER

SHIM

LOUVER3/8"

PLAN

6" SAF OVER GSMCOLLAR FLASHING

GSM COLLAR FLASHINGBEYOND

SAF ALONG ENTIRE FACE OF R.O.

REF. DWG:

SCALE:

TITLE: DWG. NO:

ATTACHED TO:

DATE:

1611 Telegraph Avenue, Suite 200Oakland, California 94612

510.465.7010 p | 510.465.8575 fwww.pyatok.com

6" = 1'-0"

2/21/2014 6:13:17 PM

01/28/14 ASK2.14R1

LOUVER JAMB DETAIL

U.C. SANTA CRUZ INFILL APARTMENTSREPAIRS 2/AK9.02 & 2/AS9.02

Page 73: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

GSM COLLAR FLASHING,BEYOND

CONT. INSTALLATION ANGLE. SETIN FULL BED OF SEALANT

CONTINUOUS AROUND OPENING.

FASTENER ANGLE TO FRAME

(EXISTING STRUCTURE) 6" SAF OVER GSM COLLARFLASHING

AIR AND WATER BARRIER.MIN. 3" INTO R.O.

PLYWOOD SHEATHING

SEALANT

FASTENER

CEMENT PLASTER W/ METALLATH

24GA GSM HEAD FLASHING, 4"FLANGE. OVER COLLAR FLASHING

REPAIR GYP. BD. FINISHWHERE OCCURS

SECURE LOUVER TO ANGLE IN AFULL BED OF SEALANT - FROMFRONT OR BACK AS REQ'D BYASSEMBLY

INSTALLATION ANGLE ATJAMBS (BEYOND). SEE DETAIL

DRAINAGE LAYER

INSECT SCREEN

LOUVER

1"

9" SAF OVER HEAD FLASHING

FULLY SOLDERED GSM COLLARFLASHING, 4" FLANGE

DRESS EDGE W/ SEALANT TOSEAL HORIZ. SEAM ABOVE(NOT SHOWN)

SAF ALONG ENTIRE FACE OF R.O.

REF. DWG:

SCALE:

TITLE: DWG. NO:

ATTACHED TO:

DATE:

1611 Telegraph Avenue, Suite 200Oakland, California 94612

510.465.7010 p | 510.465.8575 fwww.pyatok.com

6" = 1'-0"

2/21/2014 6:10:41 PM

01/28/14 ASK2.15R1

LOUVER HEAD DETAIL

U.C. SANTA CRUZ INFILL APARTMENTSREPAIRS 3/AK9.02 & 3/AS9.02

Page 74: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

(E) GYPSUM BOARD

OUTSWING EXTERIOR DOOR: SEE DOORSCHEDULE

STEEL DOOR FRAME

WEATHERSTRIPPING/ SMOKESEAL

(E) HEADERCEMENT PLASTER

LAP S.A.F. INTO DOOR R.O. AND UP WALL ASSHOWN OVER AIR AND WATER BARRIER, UNDER

HEAD FLASHING

PLYWOOD SHEATHING

DOOR FRAME ANCHOR PER MANUF.

.GSM HEAD FLASHING (PAINT)-OVERHANG OVER DOOR FRAME

9" SAF, OVER HEAD FLASHING

DRAINAGE LAYER

AIR AND WATER BARRIER CONT.MIN. 3" INTO R.O.

1/4"

GAP

DRESS EDGE W/ SEALANT TOSEAL HORIZ. SEAM

AT RATED DOORSGYP. BD. MUSTEXTEND INTO FRAMETHROAT MIN. 1/2",REPLACE INT. WALLPANELS AS REQ'D.

REF. DWG:

SCALE:

TITLE: DWG. NO:

ATTACHED TO:

DATE:

1611 Telegraph Avenue, Suite 200Oakland, California 94612

510.465.7010 p | 510.465.8575 fwww.pyatok.com

3" = 1'-0"

2/21/2014 6:08:34 PM

01/28/14 ASK2.16R1

KRESGE - EXTERIOR DOOR HEAD

U.C. SANTA CRUZ INFILL APARTMENTSREPAIRS

NOTE: 1/ AS9.10A SIMILAR (IN-SWING DOOR AT STEVENSON)

1/AK9.10A & 1/AS9.10A

Page 75: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

CEMENT PLASTER

(E) GYPSUM BOARD: 5/8"TYPE 'X'

OUTSWING EXTERIOR DOOR:SEE DOOR SCHEDULE

STEEL DOOR FRAME

WEATHERSTRIPPING/SMOKESEAL

BACKER ROD AND SEALANTPLYWOOD SHEATHING

GSM PLASTER STOP/ J-MOLD, TYP.

DOOR FRAME ANCHOR PERMANUF. MIN. 3 PER JAMB, TYP.

24 GA GSM L-METAL W/ 4" LEG. PROVIDEMIN. 1/4" CONTACT BTWN. L-METAL ANDDOOR FRAME. SEAL CONTACT POINT.

DRAINAGE LAYER

AIR AND WATER BARRIER,CONT. MIN. 3" INTO R.O.

SAF, 9" WIDE. OVER PLASTERSTOP

SAF, 6" WIDE. OVER L-METAL, UNDER PLASTERSTOPALIGN

AT RATED DOORS GYP. BD. MUST EXTENDINTO FRAME THROAT MIN. 1/2", REPLACEINT. WALL PANELS AS REQ'D.

SAF, ALONG FULL FACE OF R.O..REQ'D. ONLY IF FULL FACE OF R.O.NOT COVERED BY AIR & WATERBARRIER

AT BASE OF FRAME, SEAL FRAME TOTOPPING SLAB (FOAM AND SEALANT)

REF. DWG:

SCALE:

TITLE: DWG. NO:

ATTACHED TO:

DATE:

1611 Telegraph Avenue, Suite 200Oakland, California 94612

510.465.7010 p | 510.465.8575 fwww.pyatok.com

3" = 1'-0"

2/21/2014 6:06:35 PM

02/21/14 ASK2.17R1

KRESGE - EXTERIOR DOOR JAMB

U.C. SANTA CRUZ INFILL APARTMENTSREPAIRS

NOTE: 2/ AS9.10A SIMILAR (IN-SWING DOOR AT STEVENSON)

2/AK9.10A & 2/AS9.10A

Page 76: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

INSWING DOOR: SEE DOOR SCHEDULE

WEATHERSTRIPPING/ SMOKESEAL:SEE SPECS.

NEW CONCRETE TOPPING SLABDRAINAGE MAT

HOT FLUID APPLIED WATERPROOFING MEMBRANE, TYP.(CROSS HATCH). RUN UP ONTO SILL PAN

SEALANT & BACKER ROD

GSM SILL PAN WITH INTEGRAL END CAPS AT JAMS, SET INFULL BED OF SEALANT APPLIED UNDER SILL & END CAPS.MAINTAIN VERTICAL SHAPE OF END DAM (DO NOT CRIMPDOWN ONTO MEMBRANE). SEE DETAIL 4/AK9.10

ALUMINUM SADDLE THRESHOLD, SET INMASTIC SEALANT @ EACH END. INSTALLW/ SCREWS SET IN SEALANT.

SEAL DOOR FRAME TO CONCRETE SLAB(FOAM & SEALANT).

(EXISTING STRUCTURE)

PROTECTION BOARD. DO NOT OVERLAPLAYERS TO AVOID EXCESSIVE BUILD-UP

CANT

FLOORING

NEOPRENE REINFORCING (THICK LINE),RUN UP ONTO SILL PAN

REINFORCING FABRIC (DASHED)

2 LAYERS 1/2" CDX PLYWD

1-1/4" GYPCRETESUB-FLOORACOUSTICAL MAT

1-1/2" FACTORY-PROVIDED SCREWFASTENER. SET INSEALANT AND SEALHEAD.

8 3/4" STEEL DOOR FRAME

DOOR SHOE(PEMKO 216_FG)

.SLOPE

MA

X.

1/2"

5 1/2"

- 1/8”T.O. TOPPING SLAB

0”T.O. GYPCRETE

NOTE: 3/ AK9.10A SIMILAR (OUT-SWING DOOR AT KRESGE)

REF. DWG:

SCALE:

TITLE: DWG. NO:

ATTACHED TO:

DATE:

1611 Telegraph Avenue, Suite 200Oakland, California 94612

510.465.7010 p | 510.465.8575 fwww.pyatok.com

6" = 1'-0"

2/21/2014 5:54:14 PM

02/21/14

ASK 2.18R1EXTERIOR DOOR THRESHOLD @ LANDING

U.C. SANTA CRUZ INFILL APARTMENTS REPAIRS3/AK9.10A & 3/AS9.10A

ASI 035

Page 77: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

STEP 1:APPLY AIR& WATERBARRIERAROUNDBOLT

STEP 2:APPLY SAF"SILL" ATBOLT

STEP 3:APPLY SAF"HEAD" ATBOLT

STEP 4:APPLYSEALANTALL AROUNDBOLT & SAF

REF. DWG:

SCALE:

TITLE: DWG. NO:

ATTACHED TO:

DATE:

1611 Telegraph Avenue, Suite 200Oakland, California 94612

510.465.7010 p | 510.465.8575 fwww.pyatok.com

3" = 1'-0"

2/21/2014 6:04:13 PM

01/27/14 ASK2.20R1

SCAFFOLDING BOLT WATERPROOFINGDIAGRAM

U.C. SANTA CRUZ INFILL APARTMENTSREPAIRS 10/AS8.01, 10/AK8.01

Page 78: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

NOTE:1. TYP. EXT. DOOR FLASHING2. FABRICATE PAN FLASHING OF 24GAUGE GALVANIZED SHEET METAL.FOLD UP VERTICAL EDGE BELOWTHRESHOLD. DO NOT NAIL ATHORIZONTAL SURFACE.

SOLDER ALL JOINTS, TYP.

3/4” HIGH END DAM. HEM EDGE.SEE DETAIL.

4"

4"

5-1/2”

MATCH ROUGH OPENING WIDTH

TO TOP OFSTRUCTURAL SLAB.

FIELD VERIFY

4"

REF. DWG:

SCALE:

TITLE: DWG. NO:

ATTACHED TO:

DATE:

1611 Telegraph Avenue, Suite 200Oakland, California 94612

510.465.7010 p | 510.465.8575 fwww.pyatok.com

3" = 1'-0"

2/21/2014 6:26:24 PM

02/21/14

ASK 2.21GSM DOOR PAN FLASHING

U.C. SANTA CRUZ INFILL APARTMENTS REPAIRS4/AS9.10, 4/AK.10

Page 79: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

STD. WEIGHT CONC. TOPPING SLAB, MIN 1-1/2"

HOT FLUID APPLIED WATERPROOFINGMEMBRANE, TYP. (CROSS HATCH)

DRAINAGE MAT

(E) CONC. SLAB ON METAL DECK

HOT FLUID APPLIEDMEMBRANE FILLET

PROTECTION COURSE (GREY)

WIRE REINFORCEMENT

STAINLESS STEEL FLASHING, EXTENDABOVE DRIP EDGE OF WEEP SCREED 3"MIN. & 1/2" BELOW TOP OF PAVING. HEMBOTTOM @ EDGE

CONTINUOUS 24GA. GSM WALL FLASHING

NEOPRENE REINFORCING, RUN UP WALL

REINFORCING FABRIC (DASHED)

BACKER ROD AND SEALANT OVERCOMBRESSIBLE FILLER BOARD

REF. DWG:

SCALE:

TITLE: DWG. NO:

ATTACHED TO:

DATE:

1611 Telegraph Avenue, Suite 200Oakland, California 94612

510.465.7010 p | 510.465.8575 fwww.pyatok.com

6" = 1'-0"

2/21/2014 6:31:52 PM

02/21/14

ASK 2.22ENLARGED WALL AT LANDING

U.C. SANTA CRUZ INFILL APARTMENTSREPAIRS 10/AS8.21, 10/AK8.21

Page 80: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

STAINLES STEEL CON-FORM DECK EDGE METAL

NEOPRENE REINFORCEMENT OVER EDGE METAL.SEE DETAIL #3.

HOT FLUID APPLIED WATERPROOFING MEMBRANE, TYP.(CROSS HATCH)

DRAINAGE COMPOSITE

REMOVE EDGE OF (E) SLAB6"

1/2"

PROTECTION BOARD (GREY)

REINFORCING FABRIC (DASHED)

24GA STAINLESS STEEL EDGE METAL. SET IN WPMEMBRANE AND FASTEN @ 6" O.C., 2-ROWS STAGGERED

NEOPRENEREINFORCING WRAP, DOWN FACE OF WALL,OVER BONDING ADHESIVE

REF. DWG:

SCALE:

TITLE: DWG. NO:

ATTACHED TO:

DATE:

1611 Telegraph Avenue, Suite 200Oakland, California 94612

510.465.7010 p | 510.465.8575 fwww.pyatok.com

6" = 1'-0"

2/21/2014 4:39:58 PM

02/21/14

ASK 2.23ENLARGED DECK EDGE DETAIL

U.C. SANTA CRUZ INFILL APARTMENTSREPAIRS 9/AS8.21, 9/AK8.21

Page 81: UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE … · 2020-03-18 · STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER February 21, 2014 . Page 1 of 13 WINDOW

CEMENT PLASTER

METAL LATH

SAF

FASTENER

PLYWOOD SHEATHING

FULLY SOLDERED SHEET METALESCUTCHEON FLASHING. TO BE 2-PIECEWHERE PENETRATION IS EXISTING.

ALL

SID

ES3/

8" T

YP.

.SEE NOTE 2

SEALANT FILLETCONTINUOUS

PENETRATION, VARIES, MAYBE ROUND OR SQUARE

AIR AND WATER BARRIER. APPLYONTO PENETRATION, TYP.

DRESS EDGE W/ SEALANT TOSEAL HORIZ. SEAM, NOT SHOWN

NOTES:

WHERE SHEATHING GAP IS GREATER THAN 1/8", INSTALL LOW EXPANSION URETHANE FOAM INACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. SHAVE CURED FOAM FLUSH WITHSHEATHING.

SHEATHING GAP OF 1/8" OR LESS, TYP. ALL SIDES NO FOAM REQUIRED.

1.

2.

SEE NOTE 1BACKER ROD AND SEALANT.WHERE PENETRATION MUST BEFIRE-RATED, REPLACE BACKERROD W/ FIRE CAULKING.

REF. DWG:

SCALE:

TITLE: DWG. NO:

ATTACHED TO:

DATE:

1611 Telegraph Avenue, Suite 200Oakland, California 94612

510.465.7010 p | 510.465.8575 fwww.pyatok.com

12" = 1'-0"

2/21/2014 6:36:20 PM

02/21/14

ASK 2.24FABRICATED PENETRATION FLASHING

U.C. SANTA CRUZ INFILL APARTMENTSREPAIRS

12/AK8.01 & 12/AS8.01