uf 01
TRANSCRIPT
-
7/27/2019 UF 01
1/6
APCUltrafiltrationMembranes
ltrafiltration or UFis a pressure- drivenmembrane separation process thathelps to remove particulate matter
from aqueous solutions such as water.
APC UF membranes typically have pore sizesin the range of 0.03 m and efficiently removebacteria and most viruses, colloids, turbidityand silt. Materials that are used in UF arepolymeric and are naturally hydrophilic.
APC UF membranes are made from high-grade Polyethersulfone (PES)-based sevenpore membrane fibers material to form ahollow fiber membrane that is very durableand less prone to breakage. The hollow fiberhas a dense layer or skin on both the insideand outside surfaces, forming a double-walled structure that contributes to itsstrength. All membranes are assembled inone bundle rigidly fixed onto potting resinsand protected by a PVC housing.
APC UF membrane fouling resistance is improved by making the membrane surface morehydrophilic. With uniform pore size and inside-out flow, the UF membrane creates a barrierwithout sacrificing performance.
APC UF membranesutilize a double-walled hollow fiber membrane with a very small porediameter for excellent removal of particulate matter and bacteria, and most viruses and colloids.
-
7/27/2019 UF 01
2/6
-
7/27/2019 UF 01
3/6
Applications:
Pre-filtration of RO installations and desalinationplants
o Filtration of bacteria, viruses and other waterbornemicroorganisms
An effective alternative ( Quality and Cost )to Automatic filters (Sand, Disc, Cartridges.)
o Drinking water treatment systems, Point of Entry andPoint of Use
Ground, well, river and Lakes water filtration
Emergency drinking water system
-
7/27/2019 UF 01
4/6
-
7/27/2019 UF 01
5/6
Technical specification of theAPC Ultrafiltration membrane:
Pore size of membrane : 0.03 m
Type of membrane : Multibore / Seven Pore
Number of bores per fiber : 7
Material of membrane : Polyethersulfone
Diameter bores ID : 0.9 mm
Diameter fiber OD : 4.2 mm
MWCO : 100 150 kD
Maximum system pressure : 10 bar
Trans membrane pressure :
operation : 0.5 1 bar
maximum : 2.5 bar
Productivity clean water at 25C < 800 l/m/bar/HR
pH range during operation : 3 10
Maximum water temperature :40C& 80C(Special housing)
pH range during cleaning : 1 13
The UF membrane removes pathogens like
APC Ultrafiltration membrane effective removals of microbial infection:
Pathogenic germs: Bacterium: Micro-organisme : Fungi :
Germes arobies 37CGermes arobies 22CColiformes totaux 37CColiformes fcaux 44CStreptococoques fcaux
Escherichia coli (E-coli)Enterococcus feacallsStaphylocoque aureusStaphylocoque haemolyticusEnterabacter cloacaePseumomonas aeruginosaLegionella pneumophilaLegionella spp
Amoeba associated bacteriaMycobacteriumVibrio cholera
Entamoeba coliGiardia lambliaCrypotosporodium parvumHymenolepsia nanaSchistosoma mansoni
Ascaris suum
Cadida albicansRhodotorula mucilaginosaSaccharomyces cerevisae
Coliformestotaux Staphylocoque aureus Giardia lamblia Cadida albicans
-
7/27/2019 UF 01
6/6
Element Data Model APC-420FL
Model APC-440FL
Model APC-640 FL
Material housing PVC -U PVC-U PVC-U
Material flanges PVC -U PVC-U PVC-U
mm inch mm inch mm inch
A - Element length overall 593 23.35 1160 45.67 1220 48.0
B - Housing length 577 22.72 1060 41.73 1143 45
C - Element length 525 20.67 1010 39.36 1060 41.7
D 200 7.87 225 8.86 320 12.6
E 98 3.86 98 3.86 155 6.1
F 200 7.87 200 7.87 285 11.22Housing OD 90 3.54 90 3.54 160 6.3
Permeate connection -outer diameter 3/4 inch 3/4 inch 1 inch
Feed connection - outer diameter 3/4 inch 3/4 inch 1 inch
Flush connection - outer diameter 1/2 inch 1/2 inch 3/4 inch
Kg Ib Kg Ib Kg Ib
Weight 7 15.75 11 24.25 15 33.0
Material- Polyethersulfone x x x
Material flanges - Capillary multibore x x x
Number of bores per membrane 7 7 7
mm inch mm inch mm inch
Diameter bores ID 0.8 0.031 0.8 0.031 0.8 0.03
Diameter fiber OD 4.2 0.17 4.2 0.17 4.2 0.17MWCO ( Mol. Wt. Cut off Range) 100,000-150,000 Daltons x x x
m2
Inch2
m2
Inch2
m2
Inch
Membrane Area 2.2 3410 4.5 6975 13 1860
Typical Process Conditions
Maximum operating temperature 400
C/ 1040
F & 80 C / 208 F (S. Housing) x x x
Maximum system pressure 7.5 bar / 108.8 psi x x x
Typical TMP -Trans membrane pressure
Operation: 0.5 -1 bar / 7.25 - 14.5 psi x x x
Maximum: 2.5 bar / 36.26 psi x x x
Clean water productivity at 250C / 77
0F 800 L/m
2/Hror0.036 L/ in
2Hr x x x
Process productivity 70-120 L/m2/Hror0.00325 - 0.0054 L/ in
2Hr x x x
Backward/forward flush cycle flow 250 L/m2/Hr or 0.0113 L/ in
2/Hr x x x
M3/Hr GPM M3/Hr GPM M3/Hr GPMTypical permeate flow 100L/M2/Hr 0.22 1 o.45 2 1.3 5.73
pH range during operation PH 3-11 PH 3-11 PH 3-11
Cleaning
Soaking time during cleaning Minutes 10-15Min. 10-15Min. 10-15Min.
pH range during cleaning PH 1-11 PH 1-11 PH 1-11
Disinfecting chemicals
Hhypochlorite ( NaOCL) 50 -200 ppm 50 -200 ppm 50 -200 ppm
Hydrogen peroxide (H2O2) 100-200 ppm 100-200 ppm 100-200 ppm
UF Membrane Modules TABLE-1
5035 North Service Rd., Unit ABurlington, Ont. L7L 5
Tel: (905) 332-7669 Fax (905) 332-75
www.senvc.c