ultrasonic meters catalog fms - plandata · temperature compensation: specifications lcd 2 lines 16...

8
FMS Ultrasonic Meters Catalog Ultrasonic meter is the ideal choice for continuous and discrete measurement of level and flow for liquid, solid and gas, without physical contact We develop, build and sell standard and customized ultrasonic solutions for process control From a single instrument, to complex infrastructure, we have all you need for measure, log, transmit, process, control and monitor Under the FMS logo, Plandata join years of software and electronic experience, to the excellence of it’s partners and suppliers FMS is a commercial brand of Plandata. All other brands referenced on this document are property of their owners. Plandata CSI Ltda http://www.plandata.com.br phone 55+11+55624981 Ultrasonic measurement bring advantages because they are higienic, precise, quick, immune, reliable, simple, economic, versatile. Our systems offer a set of parameters for configuration and customization to suit your preferences and needs Shot: Power of wave Temp: Temperature of environment Sample: Intensity of measurement Freq: Frequency adjustment Password: Access protection Flume/Weir/Tank/Pipe: Choose types EngUnit: Choose engineering unit Trimpot: Digital fine calibration Output: Interface type Range: Limits of operation Margin: Stabilization under turbulence and much more Here you will find a complete guide to our ultrasonic solutions Fluid Management System

Upload: others

Post on 16-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Ultrasonic Meters Catalog FMS - Plandata · Temperature compensation: SPECIFICATIONS LCD 2 lines 16 column, keyboard 4 keys, LSD 13 x10 mm 0,5% 1% ABS, IP65-40 to +90 celcius

FMSUltrasonic Meters Catalog

Ultrasonic meter is the ideal choice for

continuous and discrete measurement

of level and flow for

liquid, solid and gas,

without physical contact

We develop, build and sell standard and customized ultrasonic solutions for

process control

From a single instrument, to complex

infrastructure, we have all you need

for measure, log, transmit, process,

control and monitor

Under the FMS logo, Plandata join years of software and electronic

experience, to the excellence of it’s partners and suppliers

FMS is a commercial brand of Plandata. All other brands referenced on this document

are property of their owners.

Plandata CSI Ltdahttp://www.plandata.com.br

phone 55+11+55624981

Ultrasonic measurement bring advantages because they are

higienic, precise, quick,

immune, reliable, simple,

economic, versatile.

Our systems offer a set of parameters for configuration and customization to

suit your preferences and needs

Shot: Power of wave

Temp: Temperature of environment

Sample: Intensity of measurement

Freq: Frequency adjustment

Password: Access protection

Flume/Weir/Tank/Pipe: Choose types

EngUnit: Choose engineering unit

Trimpot: Digital fine calibration

Output: Interface type

Range: Limits of operation

Margin: Stabilization under turbulence

and much more

Here you will find a complete guide to our ultrasonic solutions

Fluid Management System

Page 2: Ultrasonic Meters Catalog FMS - Plandata · Temperature compensation: SPECIFICATIONS LCD 2 lines 16 column, keyboard 4 keys, LSD 13 x10 mm 0,5% 1% ABS, IP65-40 to +90 celcius

Available for tanks of different sizes and shapes. .

Measurement and linearization in several engineering units like mts, kgs, lts, etc.

Specially usefull for food, beverage, chemical, environment, monitoring, oil, álcohol, mining, agriculture, water, wastewater and effluent among others.

Level range from 100 mm to 12000mm or wider on request.

Ultrasonic Level Meter/Switch

Ultrasonic Flow Meter/Switch

Non contact level measurement for liquid and solid.

Recommended for agriculture, water treatment, wastewater, effluent and others.

Several models for any type of flume like Parshall, Palmer-Bowlus, Leopold-Lagco,H, HS, etc andWeirs of type Retangular, V-notch,Cipolletti, etc.

Totalization as standard and datalog as an option.

Flow range from 0,1 l/s up to 4000 l/s or wider on request. Measure instantaneous flow

in open channel like flumes and weirs.

ULM130

UFM130

SPECIFICATIONS

LCD 2 lines 16 column, keyboard 4 keys, LSD 13 x10 mm 0,5%

1% or less than 1mm ABS, IP65

-40 to +90 celcius 1mt as standard extensible to up 100mts

-30 to +55 celcius -40 to +90 celcius

85% 100%

IP68 110VAC or 220VAC, both 50/60HZ or 24VDC

All types typical 1,6 watts max 6 watts

Analog Output: 0-10V, 4-20mA, Relays Analog Input: Pressure, Temperature and others on request Digital Rs232, Rs485, Ethernet, GSM/GPRS, SSFH Radio

Modbus as standard or customized on request

Model ULM140-1: 100mm to 2000mm Model ULM140-2: 200mm to 4000mm Model ULM140-3: 250mm to 6000mm Model ULM140-4 350mm to 8000mm Model ULM140-5 400mm to 12000mm

1,7 Kg BSP 1”

182mm x 172mm x 92mm Manual as standard, Automatic as option

Not recommended for liquids with dense foam

HMI:Repeatability:Precision:Cabinet Material and Protection: Liquid Temperature:Cable lenght:Cabinet Temperature:Transducer Temperature:Cabinet RH:Transducer RH:Transducer Protection:Power:Liquid type:Load:Interfaces options:

Digital protocol:Level range:

Weight:Process connection:Dimension:Temperature compensation:

SPECIFICATIONS

LCD 2 lines 16 column, keyboard 4 keys, LSD 13 x10 mm 0,5%

1% ABS, IP65

-40 to +90 celcius 1mt as standard extensible to up 100mts

-30 to +55 celcius -40 to +90 celcius

85% 100%

IP68 110VAC or 220VAC, both 50/60HZ or 24VDC

All types typical 1,6 watts max 6 watts

Analog Output: 0-10V, 4-20mA, Relays Analog Input: Pressure, Temperature and others on request Digital Rs232, Rs485, Ethernet, GSM/GPRS, SSFH Radio

Modbus as standard or customized on request 0,1 l/s to 4000 l/s

1,7 Kg BSP 1”

182mm x 172mm x 92mm Manual as standard, Automatic as option

Not recommended for liquids with dense foam

HMI:Repeatability:Precision:Cabinet Material and Protection: Liquid Temperature:Cable lenght:Cabinet Temperature:Transducer Temperature:Cabinet RH:Transducer RH:Transducer Protection:Power:Liquid type:Load:Interfaces options:

Digital protocol:Flow range:Weight:Process connection:Dimension:Temperature compensation:

Page 3: Ultrasonic Meters Catalog FMS - Plandata · Temperature compensation: SPECIFICATIONS LCD 2 lines 16 column, keyboard 4 keys, LSD 13 x10 mm 0,5% 1% ABS, IP65-40 to +90 celcius

Ultrasonic Flow Meter

Measure instantaneous and totalized, volumetric liquid flow in pipes (clamp-on)

Available for pipes of different material like steel, iron and many plastics.

Non-intrusive external clamp-on transducers, no need to cut or drill pipes.

Interference free. No pressure drop.

Large standard flow range from 10 l/s to 4000 l/s or other on request.

Wide range of pipe diameters coverage 25mm to 6000 mm. Almost all type of liquids.

Datalog standard available.

SPECIFICATIONS

LCD 2 lines 16 column, keyboard 4 keys 0,5%

1% IP65 0 to 100 celcius

5mts as standard or customized -30 to +80 celcius

-40 to +100 celcius 85%

100% IP68 1 mt water immersion

110VAC or 220VAC, both 50/60HZ or 24-36VDC All types with <10000 ppm solids suspension 10 l/s to 4000 l/s

Analog Output: 0-10V, 4-20mA, Relays Analog Input: Pressure, Temperature and others on request Digital Rs232, Rs485, Ethernet, GSM/GPRS, SSFH Radio

Modbus as standard or customized

Model UFM140-1: 12,5mm to 100mm Model UFM140-2: 50mm to 700mm Model UFM140-3: 275mm to 6000mm

2,5 KgNot recomended for lined pipes (see our UFM150 models)

HMI:Repeatability:Precision:Cabinet Protection:Liquid Temperature:Cable lenght:Cabinet Temperature:Transducer Temperature:Cabinet RH:Transducer RH:Transducer Protection:Power:Liquid type:Flow range:Interfaces options:

Digital protocol:Pipe diameters:

Weight:

UFM140

Measure instantaneous and totalized, volumetric liquid flow in pipes (wetted)

Suitable for pipes of different material like steel, iron and many plastics. For use with pipes that can not accept external transducers like lined pipes.

Intrusive transducers.Require drill into pipes.

Minimal negligible pressure drop, less than 0,1%

Large standard flow range from 10 l/s to 4000 l/s or other on request.

Wide range of pipe diameters coverage 80mm to 6000 mm. Almost all type of liquids.

Better precision.

Datalog standard available.

Ultrasonic Flow Meter UFM150 SPECIFICATIONS

LCD 2 lines 16 column, keyboard 4 keys 0,5%

Less than 1% IP65 0 to 100 celcius

5mts as standard or customized -30 to +80 celcius

-40 to +100 celcius 85%

100% IP68 1 mt water immersion

110VAC or 220VAC, both 50/60HZ or 24-36VDC All types with <10000 ppm solids suspension 10 l/s to 4000 l/s

Analog Output: 0-10V, 4-20mA, Relays Analog Input: Pressure, Temperature and others on request Digital Rs232, Rs485, Ethernet, GSM/GPRS, SSFH Radio

Modbus as standard or customized

Model UFM150-1: 80mm to 200mm Model UFM150-2: 180mm to 700mm Model UFM150-3: 500 to 6000mm

2,5 KgNot recomended for pipes bellow 80mm (see our UFM160 models)

HMI:Repeatability:Precision:Cabinet Protection:Liquid Temperature:Cable lenght:Cabinet Temperature:Transducer Temperature:Cabinet RH:Transducer RH:Transducer Protection:Power:Liquid type:Flow range:Interfaces options:

Digital protocol:Pipe diameters:

Weight:

Page 4: Ultrasonic Meters Catalog FMS - Plandata · Temperature compensation: SPECIFICATIONS LCD 2 lines 16 column, keyboard 4 keys, LSD 13 x10 mm 0,5% 1% ABS, IP65-40 to +90 celcius

Ultrasonic Flow Meter

Available for pipes of different material like steel, iron and many plastics.

Flow cell, with pre assembled transducers providerobust and long term stability.

Interference free. No pressure drop.

Medium standard flow range from 10 l/s to 3000 l/s

Specific range of pipe diameters coverage 10mm to 1000 mm. Almost all type of liquids.

Datalog standard available.

SPECIFICATIONS

LCD 2 lines 16 column, keyboard 4 keys 0,5%

Less than 1% IP65 0 to 100 celcius

5mts as standard or customized -30 to +80 celcius

-40 to +100 celcius 85%

100% IP68 1 mt water immersion

110VAC or 220VAC, both 50/60HZ or 24-36VDC All types with <10000 ppm solids suspension 10 l/s to 3000 l/s

Analog Output: 0-10V, 4-20mA, Relays Analog Input: Pressure, Temperature and others on request

Digital Rs232, Rs485, Ethernet, GSM/GPRS, SSFH Radio Modbus as standard or customized

Model UFM160-1: 10mm to 50mm Model UFM160-2: 50mm to 1000mm

Available on request Steel and Iron

HMI:Repeatability:Precision:Cabinet Protection:Liquid Temperature:Cable lenght:Cabinet Temperature:Transducer Temperature:Cabinet RH:Transducer RH:Transducer Protection:Power:Liquid type:Flow range:Interfaces options:

Digital protocol:Pipe diameters:

Weight:Flow Cell Material:

Measureinstantaneous and totalized, volumetric liquid flow in pipes (flow cell)

UFM160

Ultrasonic Flow Meter

Measureinstantaneous and to volum in pi

talized,etric liquid flow

pes (portable)

Available for pipes of different material like steel, iron and many plastics.

Non-intrusive external clamp-on transducers, no need to cut or drill pipes. Password protected.

Interference free. No pressure drop.

Large standard flow range from 10 l/s to 4000 l/s or other on request.

Wide range of pipe diameters coverage 25mm to 6000 mm. Almost all type of liquids.

Datalog standard included. Wireless supervisory via Spread Spectrum Radio or GSM/GPRS on request.

Battery charger included. Standard battery for 10 hours of continuous operation.

SPECIFICATIONS

LCD 4 lines 16 column, keyboard 18 keys 0,5%

Less than 1% IP65 0 to 100 celcius

5mts as standard or customized on request -30 to +80 celcius

-40 to +100 celcius 85%

100% IP68

110VAC or 220VAC, both 50/60HZ for charger All types with <10000 ppm solids suspension 10 l/s to 4000 l/s

Analog Output: 0-10V, 4-20mA, Relays Analog Input: Pressure, Temperature and others on request Digital Rs232, Rs485, Ethernet, GSM/GPRS, SSFH Radio

Modbus as standard or customized

Model UFM170-1: 12,5mm to 100mm Model UFM170-2: 50mm to 700mm Model UFM170-3: 275 to 6000mm

6 KgAAA rechargeable NiMH

HMI:Repeatability:Precision:Cabinet Protection:Liquid Temperature:Cable lenght:Cabinet Temperature:Transducer Temperature:Cabinet RH:Transducer RH:Transducer Protection:Power:Liquid type:Flow range:Interfaces options:

Digital protocol:Pipe diameters:

Weight:Battery:

UFM170

Page 5: Ultrasonic Meters Catalog FMS - Plandata · Temperature compensation: SPECIFICATIONS LCD 2 lines 16 column, keyboard 4 keys, LSD 13 x10 mm 0,5% 1% ABS, IP65-40 to +90 celcius

Ultrasonic Flow Meter

Measureinstantaneous and totalized, volumetric gas flow in pipes (clamp-on)

Available for pipes of different material like steel, iron and many plastics. Messure flow of most kind of gás including natural, corrosive, tóxic, compressed air etc ...

Non-intrusive external clamp-on transducers, no need to cut or drill pipes.

Interference free. No pressure drop.

Large standard flow range from 14 m/s to 150 m/s.

Wide range of pipe diameters coverage 20mm to 600 mm. Support several temperature and pressure profiles.

Datalog standard available. Explosion proof as option Class 1, Div 1, Groups BCD.

SPECIFICATIONS

LCD 2 lines 16 column, keyboard 34 keys 0,5%

1% to 5% depending on diameter and channels used IP65

-40 to +230 celcius 5mts as standard or customized

-10 to +55 celcius -20 to +60 celcius

85% 100%

IP68 110VAC or 220VAC, both 50/60HZ or 24VDC

All types with minimum density volume 0-1000000 m3/s, velocity 14-150 m/s

Analog Output: 0-10V, 4-20mA, Relays Analog Input: Pressure, Temperature and others on request

Digital Rs232, Rs485, Ethernet, GSM/GPRS, SSFH Radio Modbus as standard or customized

Model UFM180-1: 20mm to 100mm Model UFM180-2: 100mm to 200mm Model UFM180-3: 200mm to 300mm Model UFM180-4: 300mm to 600mm

5Kg Steel and Aluminun

360x290x130 mm 20D upstream, 10D downstream, free flow

HMI:Repeatability: <Precision:Cabinet Protection:Gas Temperature:Cable lenght:Cabinet Temperature:Transducer Temperature:Cabinet RH:Transducer RH:Transducer Protection:Power:Gas type:Flow range:Interfaces options:

Digital protocol:Pipe diameters:

Weight:Transducer Material:Dimension:Requirement:

UFM180

Measureinstantaneous and totalized, volumetric steam flow in exhaust or waste pipes and chimneys (wetted)

Available for pipes and tubulation of any material like steel, iron, concrete and plastics. Measure flow of most kind of vapor and smoke.

Intrusive transducers..

Negligible interference to flow.

Support aggressive, high dust, high temperature and low speed media.

Standard flow range from 0 m/s to 40 m/s.

Wide range of pipe diameters coverage 1000mm to 10000 mm. Support several temperature and pressure profiles with automatic compensation.

Datalog standard available.

SPECIFICATIONS

LCD 2 lines 16 column, keyboard 34 keys 0,5%

2% depending on diameter and channels used Ip54, Ip65 depending on parts

0 to +400 celciusFan system for transducer cooling and cleaning

-10 to +50 celcius -40 to +80 celcius

85% 100%

IP68 110VAC or 220VAC, both 50/60HZ or 24VDC

Smoke and Vapor volume 0-3000000 m3/h, velocity 0-40 m/s

Analog Output: 0-10V, 4-20mA, Relays Analog Input: Pressure, Temperature and others on request

Digital Rs232, Rs485, Ethernet, GSM/GPRS, SSFH Radio Modbus as standard or customized

Model UFM190-1: 2000mm to 5000mm Model UFM190-2: 3500mm to 8000mm Model UFM190-3: 4500mm to 10000mm

25 to 35Kg Steel and Ceramic

360x400x230 mm 20D upstream, 10D downstream, free flow

HMI:Repeatability: <Precision:Cabinet Protection:Gas Temperature:Ventilation: Cabinet Temperature:Transducer Temperature:Cabinet RH:Transducer RH:Transducer Protection:Power:Media type:Flow range:Interfaces options:

Digital protocol:Duct diameters:

Weight:Transducer Material:Dimension:Requirement:

Ultrasonic Flow Meter UFM190

Page 6: Ultrasonic Meters Catalog FMS - Plandata · Temperature compensation: SPECIFICATIONS LCD 2 lines 16 column, keyboard 4 keys, LSD 13 x10 mm 0,5% 1% ABS, IP65-40 to +90 celcius

Digital Interfaces (options)

Provide easy way for monitoring, controling and supervisioning your instrument and data remotely.

Data output and configuration input using standardModbus RTU protocol or a customized protocol on request.

Baudrates up to 115Kbps

Deliver measured data directly into your PC or PLC.

Serial Rs232and Rs485CommunicationInterfaces

SPECIFICATIONS

Rs232: 5-15 mts depending on environment Rs485: 500-1000 mts depending on environment

IP65 -40 to +90

Connector type: Standard DB9Cable Range:

Connector Protection:Operation Temperature:

Ethernet TCP/IPCommunicationInterface

Provide easy way for monitoring, controling and supervisioning your instrument and data remotely.

Data output and configuration input using standardModbus TCP protocol or a customized protocol on request.

Baudrates up to 100/1000Kbps

Deliver measured data directly into your LAN(local area network) or WAN (wide area network).

Conventional: 250 mts depending on environment Fiber Optic: > 1000 mts

IP65 -40 to +90

SPECIFICATIONS

Connector type: Standard RJ45Cable Range:

Connector Protection:Operation Temperature:

Page 7: Ultrasonic Meters Catalog FMS - Plandata · Temperature compensation: SPECIFICATIONS LCD 2 lines 16 column, keyboard 4 keys, LSD 13 x10 mm 0,5% 1% ABS, IP65-40 to +90 celcius

GSM/GPRSCellular WireLessCommunicationInterface

Provide a way to connect your instrument each other or to a remote Data Base Server or SCADA.

You may store data into the Data Base Server supplied by your local carrier or we can develop your own custom, private Data Base Server on request. Data Base Server collect and store your data over a LAN(local area network) or WAN (wide area network).

GSM dual band.

Data output and configuration input using standardModbus TCP, HTTP, OPCServer, SMS protocols or a customized protocol on request.

Baudrates up to 14Kbps.

Global approvals and most carriers compatibility.

MMCX/SIM 850/1900MHz and 900/1800MHz

10 1 and 2

-30 to +55 Yes

Yes

Ascii TXT, DBF, MSSQL, XLS Excell, or other on request

Modbus TCP, HTTP, OPCServer, SMS or custom Up to 4000 points/station

Windows 200x for Data Base & SCADA

SPECIFICATIONS

Antenna Connector type:GSM band:GPRS Class:GSM Class:Operation Temperature: Dial up:Auto Answer:DataBase Options:

Protocols:SCADA:Requirements:

FHSS RadioDigitalWireLess CommunicationInterface

Provide a way to connect your instrument each other or to a remote Data Base Server or SCADA.

You may store data into the Data Base Server supplied by your IT or we can develop a custom Data Base Server on request. Data Base Server store your data collected from a LAN(local area network) or WAN (wide area network).

FHSS Frequency Hopping Spread Spectrum is licence free on most countries.

Data output and configuration input using standardModbus RTU, Modbus TCP protocol or a customized protocol on request.

Baudrates up to 19Kbps. Deliver data right into your PC, PLC, LAN or WAN..

Standard ISM 902/928MHz

-30 to +55 Programable max1 Watt

Point to Point, Point to Multipoint, Multipoint to Multipoint

Ascii TXT, DBF, MSSQL, Excell XLS, or other on request

12VDC -100dBm

48 +- 32Km with line of sight

max 19Kbps Rs232, Rs485, Ethernet

Modbus RTU or Modbus TCP 22 x 75 x 110 mm

Windows 200x for Data Base & SCADA

SPECIFICATIONS

Antenna Connector Type:Band:Operation Temperature: Load:Topologies:DataBase Options:

Power:Sensitivity:Channels:Range:Baud Rate:Digital Output:Protocol:Dimensions:SCADA: Up to 4000 points/stationRequirements:

Page 8: Ultrasonic Meters Catalog FMS - Plandata · Temperature compensation: SPECIFICATIONS LCD 2 lines 16 column, keyboard 4 keys, LSD 13 x10 mm 0,5% 1% ABS, IP65-40 to +90 celcius

Analog OutputInterface0-5V, 0-10V4-20mA, 0-20mA

Analog Interfaces (options)

Analog signaling output.Output the engineering unit of your choice.Voltage 0-10VDC or 0-5VDCCurrent 4-20mA or 0-20mAHigh resolution.High immunity.Long distance cabling.1 to 5 output per instrument

16 bits Max 700 OhmsI

-30 to +55 24VDC

1 to 5 each meter

SPECIFICATIONS

Resolution:Impedance:Operation Temperature: Voltage for current loop:Outputs:

Relays OutputInterface110VAC, 220VAC,24VDC

Resistive 5Ah 120VAC or 240VAC or 24VDC

-40 to +70 max 10Ahmax 50 Ohms

300 switch/min 10ms max

5ms max Silver alloy

SPECIFICATIONS

Load Type:Nominal Power Rate:Operation Temperature: Switching Current:Initial Resistance: Mechanical Life:Switch Time:Release Time:Contact Material:

Ideal for pump, valves, mixers, alarms etc..Double set points assignmentsSpecial set points on request.3 relays 5Ah, 6 relays 2Ah and 9 relays 1Ah as standard or custom specification on request.

Auxiliar Sensor InputInterface.Temperature,Pressureand others

We integrate auxiliar sensor inputs to improve your ultrasonic flow & level FMS metering system.

Pressure, Temperature and more.

For compensation, for process control or research.

Especial software routines can be made on request.

Robust and reliable sensors supplied by our market leader partners.

Steel AISI 316 Better than 0,25%

-25 from +75 24VDC to 36VDC

from Ip65 to Ip68 Immersible available on request 0/160mmCA to 0/2500mmCA

-20C to +600C

SPECIFICATIONS

Materials:Precision:Operation Temperature: Voltage for current loop:Protection: Pressure Ranges:Temperature Ranges:

FMS is a commercial make of Plandata. All other makes are property of their owners. Plandata reserve the right to modify any specification without previous advertise