Page 1: Underfloor Heating Specialists - IBD Distribution | The ... Spreader Plates (Double Groove) ensure even and speedy distribution of heat from underfloor heating pipes and the correct

Underfloor Heating Specialists

Page 2: Underfloor Heating Specialists - IBD Distribution | The ... Spreader Plates (Double Groove) ensure even and speedy distribution of heat from underfloor heating pipes and the correct

Envirotube will design, deliver and can even install your system giving you the complete solution.

New BuildsRenovations

Barn Conversions Luxury Apartments

Offices Schools and Nursing Homes

Extensions Conservatories

There are a huge number of benefits to using an underfloor heating system. Here are just a few of them:

Comfort – a correctly designed and installed system runs efficiently and supports the body’s natural requirements for warm feet and a cool head. The heat rise uniformly from

the floor rather than having warm pockets around radiators.

Silence – underfloor heating is virtually silent running.

Low Maintenance – no need for manual operations such as bleeding radiators.

Cost effective – lower water temperature means lower heating bills.

Space – more space in the property as there are no radiators to get in the way.

Aesthetics – no radiators to get in the way of where you want to place your furniture.

Individual room control – you control what temperature your rooms are heated to on an individual basis – for example you can have your bedroom at a different temperature from

your living room.

Healthy living – less dust movement in the room and floors will dry more quickly after cleaning.

Environment – lower fuel usage means lower CO2 emissions, better for the environment.

What makes us different?

Envirotube specialises in designing bespoke energy efficient underfloor heating that meets all heating needs.

Why use underfloor heating?

Page 3: Underfloor Heating Specialists - IBD Distribution | The ... Spreader Plates (Double Groove) ensure even and speedy distribution of heat from underfloor heating pipes and the correct

The Envirotube underfloor heating solution provides a fully warranted product which is de-signed specifically for your installation.This guarantees compatibility with the primary generator whether that be a conventional fuel powered boiler or a renewable energy source, such as a heat pump system. This is espe-cially important if you are using a heat pump, as the efficiency of the system is compromised if the heat emitter is not designed to match its output and operating parameters.

All Envirotube systems are designed using BS EN 12831 standard heat loss calculations and in strict accordance with the Microgeneration Certification Scheme quality guidelines. This ensures that the system will perform as it is designed to do and the energy efficiencies of the primary generator are safeguarded.

Envirotube systems are also very easy to commission and to put in into operation. As well as providing all the information needed by the installer, all manifolds include flow meters, temperature gauges (on both flow and return) and automatic air vents. Installation instruc-tions are provided on A3 sized plastic laminated sheets. These contain all the information the installer requires to ensure that the system performs as intended.

The solution comprises:• EU Standards Compliant Pex-a and Pex-Al-Pex Pipe• Manifold Systems• Room Thermostat Control System• Design and Commissioning Drawings and Documentation• 15 year Insurance Backed Warranty

Our Design Service

Page 4: Underfloor Heating Specialists - IBD Distribution | The ... Spreader Plates (Double Groove) ensure even and speedy distribution of heat from underfloor heating pipes and the correct

Aluminium Spreader Plates (Double Groove) ensure even and speedy distribution of heat from underfloor heating pipes and the correct positioning of the pipes during installation.

Standard ‘Over Joist’ Aluminium Spreader Plate

Reverse ‘Fit From Below’ Aluminium Spreader Plates

Specification:- Reverse aluminium Spreader Plates fit underneath floor boards and between joists.- Aluminium Spreader Plates are designed to fit between numerous joist sizings.- Pipework easily clips into preformed grooves.- Underfloor heating pipe is fixed in the grooves of the plates, insulation is placed in the void below the plates to minimise downward heat loss and dissipate the heat even across the floor.

Specification: - Aluminium Spreader Plates (Double Bend) ensure even and speedy distribution of heat from under-floor heating pipes to fit into situations where the floor has already been laid.- Reverse aluminium Spreader Plates fit underneath floor boards and between joists.- Aluminium Spreader Plates are designed to fit between numerous joist sizings.- Pipework easily clips into preformed grooves.- Underfloor heating pipe is fixed in the grooves of the plates, insulation is placed in the void below the plates to minimise downward heat loss and dissipate the heat even across the floor.- Insulation is then installed up against the plates.

Aluminium Spreader Plates (Double Groove) ensure even and speedy distribution of heat from underfloor heating pipes and the correct positioning of the pipes during installation.

Standard Groved Foil Back Foamboard

Grooved Chipboard Floor

Pre-grooved Insulation Panels comprise a rigid thermal insulation material with radiuses grooves suitable for standard 16mm underfloor heating pipe.

Suitability:-New build -Extensions -Retrofits

Suitability:- New builds (Timber frame) - Below joists - Retrofits

Specification:- Aluminium foil covers the surface of the foam board to minimalise heat loss through the floor.- Perfect for a variety of installation types.- Fast quick and easy to install.- Great for levelling miss matched floor heights.

Suitability:- Existing properties - Over timber joist for first floors- Extension refurbishments

Page 5: Underfloor Heating Specialists - IBD Distribution | The ... Spreader Plates (Double Groove) ensure even and speedy distribution of heat from underfloor heating pipes and the correct

Pre-grooved foil face 22mm board with radiuses grooves of a specified diameter and pattern positioned in the upper surface. Foil face heat diffusion layer covering all of the board including the grooves and then the continuous pipework is pressed into place.

Suitability:- Existing properties - Over timber joist for first floors- Extension refurbishments

Grooved Chipboard Floor

Low Profile Grooved Foil Back Foamboard

Specification:- The choice of insulation material, panel thickness and the diameter and pattern of the grooves is be-spoke to the client’s specific design and performance requirements.- Pre-grooved Insulation Boards provide a flexible, cost effective solution for Floating Floors, Suspended Timber Floors, Floor on Floor and Battened Floor systems.-No supplementary fixings are required as the process of pressing the pipework into the diffusion plates is sufficient to retain it securely in the correct position.

Suitability:- Existing properties - Over timber joist for first floors- Extension refurbishments

Pre-grooved Insulation Panels comprise a rigid thermal insulation material with radiuses grooves suitable for standard 12mm under-

Specification:- Pre-grooved Insulation panels comprise a rigid thermal insulation material with radii grooves of a specified diameter and pattern positioned in the upper surface. - Aluminium foil covers the surface of the foam board to minimalise heat loss through the floor.- Perfect for retrofitting properties with limited ceiling height.- Great for levelling miss matched floor heights.- Cost effective solution.

Profix Panel

Specification:- Extremely low 18mm overall thickness.- The snap clips help to fasten the panels together and the multiple break points with V shaped notches aid in cutting knife alignment.- Benefits from a unique slide and lock to connect the panels together.- Ultra-low profile for either a 10mm or a 12mm pipe.

The high structural integrity of the Profix Panel enables the direct appli-cation of a highly thermally conductive screed replacement board which, in addition to optimising heat transfer, enables either a tiled, vinyl, or thin laminate floor to be bonded directly to it or for a low tog carpet and underlay to be laid directly onto it. Suitability:- Retrofits- New builds/Extensions/Renovations - Over existing flooring/ Any floor covering

Page 6: Underfloor Heating Specialists - IBD Distribution | The ... Spreader Plates (Double Groove) ensure even and speedy distribution of heat from underfloor heating pipes and the correct

Standard Screed Installation

Specification:-Very High heat output -Tried and tested solution which is the most cost effective solution for new builds-Underfloor heating is fully sealed within the buildings construction-Very simple to install

Screeded floor systems are the most common underfloor heating system for the ground floor level in properties (Or other levels a beam and block flooring is in place) The heating pipe is clipped via staples or using a clip rail system to the board to hold the pipe in place whilst the screed is either poured or laid on top.

Manifold Systems

Suitability:- New Build - Extensions - Over solid concrete slab - Beam and block

Envirotube manifold systems are supplied to suit the application. Low temperature heat pump systems will normally have a circulating pump integral to the system suitable for supporting the Un-derfloor Heating System without the need for additional pumps. Boilers will require blending valves and circulation pumps on the manifold. To comply with underfloor heating installation standards a “high limit” thermostat must also be fitted. All Envirotube high temperature manifolds include these as standard items.

Page 7: Underfloor Heating Specialists - IBD Distribution | The ... Spreader Plates (Double Groove) ensure even and speedy distribution of heat from underfloor heating pipes and the correct

Multi-layer pipe for heating systems only, made from a 5-layer composite material using PE-RT as the inner and outer layers coupled with a 0.25mm thick aluminium core. The two further layers are adhesive, to band the aluminium to the inner and outer PE-RT layer.PERT/AL/PE-RT Alpert multilayer can run straight from a distribution point to an outlet point without the need to cut the pipe. This reduces the requirement for joints thus reducing the possibility of leaks. Multi-layer pipe has no memory so it doesn’t spring or resist when laying, so it is ideal for single installer.

The Envirotube 5-layer high quality PE-RT has a very high flexibility, even more flexible than tradi-tional PE-X pipes. The production line in the factory in Sweden is equipped with high technical detection devices to make sure all pipes are leaving the factory in absolute top quality condition. Our pipe can be produced in any dimension used for floor heating applications. Generally, PE-RT pipes are coiled from 200m. The length of the coil is of course customised upon request.

80m, 100m, 120m and 500mPipe DimensionsCoil SizeOperating TemperatureMax TemperatureMax Pressure Mechanical PropertiesCompositionPipe RoughnessMin Bend Radius Water Capacity Thermal Properties Thermal Conductivity Expansion Coeffiecient

General

70° C95° C

10.0 Bar

Inner Pipe PE-RT / External Pipe PE-RT0.007 mm/m

5 x OD Water Capacity mm - 0.113l/m

0.45 W/m K0.026 mm/m K

16mm OD x 12mm ID x 2.0mm WT

DensityProperty

Softening TemperatureElongation At BreakTensile Strength

Expansion Coeffiecient Thermal Conductivity

0.93 - 0.94 g/cm³Value

> 120° C>500%17MPa

0.4 W/(m K)

MultiAI Pipe (PE-RT/AL/PE-RT)

Key Benefits:- No incrustation- Oxygen diffusion tight- Corrosion resistance- Low weight- High form stability after bending- Excellent long-run life expectancy- Easy, fast and safe installation

FlexiP Pipe (PE-RT)

Key Benefits:- Outstanding PE-Xa material- No incrustation- Oxygen diffusion tight- Corrosion and abrasion resistance- Low weight- Bending flexibility- Excellent long-run behaviour- High chemical resistance

Page 8: Underfloor Heating Specialists - IBD Distribution | The ... Spreader Plates (Double Groove) ensure even and speedy distribution of heat from underfloor heating pipes and the correct

Envirotube UK LtdUnit 11 Enterprise Park

Black Moor RoadEbblake Industrial Estate

VerwoodDorset

BH31 6YSTel: 01202 825682Fax: 01202 827933

www.envirotube.co.uk

· All systems designed for your specific project· Supports MCS MIS3005 for Heat Pump Applications

· Includes web enabled control systems with iPhone and iPad apps· 15 year Insurance Backed Warranty

· Full design documentation with commissioning drawings