unsolicited alarm and information messages reference · unsolicited alarm and information messages...
TRANSCRIPT
EAGLEUnsolicited Alarm and Information Messages Reference
Release 46.5
E86978 Revision 3
January 2018
EAGLE Unsolicited Alarm and Information Messages Reference, Release 46.5
E86978 Revision 3
Copyright © 1993, 2018, Oracle and/or its affiliates. All rights reserved.
This software and related documentation are provided under a license agreement containing restrictions onuse and disclosure and are protected by intellectual property laws. Except as expressly permitted in yourlicense agreement or allowed by law, you may not use, copy, reproduce, translate, broadcast, modify, license,transmit, distribute, exhibit, perform, publish, or display any part, in any form, or by any means. Reverseengineering, disassembly, or decompilation of this software, unless required by law for interoperability, isprohibited.
The information contained herein is subject to change without notice and is not warranted to be error-free. Ifyou find any errors, please report them to us in writing.
If this is software or related documentation that is delivered to the U.S. Government or anyone licensing it onbehalf of the U.S. Government, then the following notice is applicable:
U.S. GOVERNMENT END USERS: Oracle programs, including any operating system, integrated software,any programs installed on the hardware, and/or documentation, delivered to U.S. Government end users are"commercial computer software" pursuant to the applicable Federal Acquisition Regulation and agency-specific supplemental regulations. As such, use, duplication, disclosure, modification, and adaptation of theprograms, including any operating system, integrated software, any programs installed on the hardware,and/or documentation, shall be subject to license terms and license restrictions applicable to the programs.No other rights are granted to the U.S. Government.
This software or hardware is developed for general use in a variety of information management applications.It is not developed or intended for use in any inherently dangerous applications, including applications thatmay create a risk of personal injury. If you use this software or hardware in dangerous applications, then youshall be responsible to take all appropriate fail-safe, backup, redundancy, and other measures to ensure itssafe use. Oracle Corporation and its affiliates disclaim any liability for any damages caused by use of thissoftware or hardware in dangerous applications.
Oracle and Java are registered trademarks of Oracle and/or its affiliates. Other names may be trademarks oftheir respective owners.
Intel and Intel Xeon are trademarks or registered trademarks of Intel Corporation. All SPARC trademarks areused under license and are trademarks or registered trademarks of SPARC International, Inc. AMD, Opteron,the AMD logo, and the AMD Opteron logo are trademarks or registered trademarks of Advanced MicroDevices. UNIX is a registered trademark of The Open Group.
This software or hardware and documentation may provide access to or information about content, products,and services from third parties. Oracle Corporation and its affiliates are not responsible for and expresslydisclaim all warranties of any kind with respect to third-party content, products, and services unlessotherwise set forth in an applicable agreement between you and Oracle. Oracle Corporation and its affiliateswill not be responsible for any loss, costs, or damages incurred due to your access to or use of third-partycontent, products, or services, except as set forth in an applicable agreement between you and Oracle.
Contents
1 About This User's Guide
Overview.................................................................................................................................................... 1-1
Scope and Audience ................................................................................................................................. 1-1
Documentation Admonishments ........................................................................................................... 1-2
Manual Organization .............................................................................................................................. 1-2
My Oracle Support (MOS)....................................................................................................................... 1-3
Emergency Response................................................................................................................................ 1-3
Related Publications ................................................................................................................................. 1-4
Customer Training.................................................................................................................................... 1-4
Locate Product Documentation on the Oracle Help Center Site ....................................................... 1-4
2 Message Type
System Alarm Levels................................................................................................................................ 2-1
Output Messages ...................................................................................................................................... 2-1
Unsolicited Alarm Messages (UAM) ..................................................................................................... 2-3
Unsolicited Information Messages (UIM)............................................................................................. 2-3
3 UAM and UIM Troubleshooting Procedures
UAMs.......................................................................................................................................................... 3-1
0001 - Card has reset ........................................................................................................................ 3-1
0008 - Active MASP has become isolated ..................................................................................... 3-1
0012 - Invalid HW for Integrated Measurements ........................................................................ 3-2
0013 - Card is isolated from the system......................................................................................... 3-2
0028 - IMT Bus util rate exceeds major thresh.............................................................................. 3-3
0031 - HIPR2 detected a major Congested Second...................................................................... 3-4
0041 - LSMS bulk load required ..................................................................................................... 3-5
0047 - Card type not valid for application .................................................................................... 3-5
0051 - TSC sync is in simplex mode............................................................................................... 3-5
0053 - Standby TDM failure ............................................................................................................ 3-5
0058 - Critical customer trouble detected ..................................................................................... 3-6
0059 - Major customer trouble detected ........................................................................................ 3-6
0063 - Critical holdover clock trbl detected .................................................................................. 3-7
iii
0064 - Major holdover clock trouble detected .............................................................................. 3-7
0077 - Card temperature is critical lvl:T2 ...................................................................................... 3-7
0078 - Card temperature exceeds nominal lvl:T1....................................................................... 3-11
0080 - Shelf FAN bit is OFF ........................................................................................................... 3-16
0081 - Shelf FAN bit is ON ............................................................................................................ 3-16
0082 - Alarm in Fuse panel............................................................................................................ 3-16
0084 - IP Connection Unavailable ................................................................................................ 3-17
0088 - Clocks A and B TSCs are out of sync ............................................................................... 3-28
0092 - MDAL not responding ....................................................................................................... 3-29
0099 - Incompatible HW for provisioned slot ............................................................................ 3-29
0108 - Major IMT failure detected ................................................................................................ 3-30
0111 - Failure on both IMT A and IMT B..................................................................................... 3-33
0112 - Major failures detected on both IMTs............................................................................... 3-33
0115 - Linkset IP TPS threshold exceeded................................................................................... 3-33
0120 - ENUM SYSTEM is not available....................................................................................... 3-35
0121 - ENUM SYSTEM is available.............................................................................................. 3-35
0122 - ENUM SYSTEM normal, card(s) abnormal .................................................................... 3-35
0123 - ENUM SYSTEM is removed.............................................................................................. 3-36
0124 - ENUM Threshold -Level1 exceeded ................................................................................ 3-36
0125 - ENUM Threshold -Level 2 exceeded ............................................................................... 3-36
0126 - ENUM Threshold Condition cleared ............................................................................... 3-37
0127 - ENUM card capacity exceeded ......................................................................................... 3-37
0128 - All clocks have failed.......................................................................................................... 3-37
0129 - ENUM Card TPS is normal................................................................................................ 3-38
0132 - Loading failed: table not found......................................................................................... 3-38
0133 - Loading failed: data read Error......................................................................................... 3-38
0134 - Loading failed: bad checksum returned .......................................................................... 3-39
0135 - Loading failed: GPL load timeout .................................................................................... 3-39
0136 - Loading failed: data load timeout .................................................................................... 3-40
0137 - Loading failed: invalid GPL .............................................................................................. 3-40
0138 - Loading failed: GPL format error ..................................................................................... 3-40
0139 - Loading failed: disk read prep error ................................................................................ 3-41
0140 - Loading failed: disk read response error ......................................................................... 3-41
0141 - Loading failed: disk read failed ........................................................................................ 3-41
0152 - LIM(s) have been denied STPLAN service ..................................................................... 3-42
0153 - STPLAN not available ........................................................................................................ 3-42
0157 - OA&M IP Security feature risk detected ......................................................................... 3-43
0158 - OA&M IP Security feature risk cleared ........................................................................... 3-43
0162 - 1116-P, 1116-S clocks failed................................................................................................. 3-44
0164 - 1114-S, 1116-S clocks failed................................................................................................. 3-44
0166 - 1114-S, 1116-P, 1116-S clocks failed.................................................................................... 3-45
0169 - 1114-P, 1116-P clocks failed................................................................................................. 3-45
0170 - 1114-P, 1116-P, 1116-S clocks failed .................................................................................... 3-46
iv
0171 - 1114-P, 1114-S clocks failed................................................................................................. 3-47
0172 - 1114-P, 1114-S, 1116-S clocks failed.................................................................................... 3-47
0173 - 1114-P, 1114-S, 1116-P clocks failed.................................................................................... 3-48
0185 - 1116-PHS, 1116-SHS clocks failed...................................................................................... 3-49
0187 - 1114-SHS, 1116-SHS clocks failed...................................................................................... 3-50
0189 - 1114-SHS, 1116-PHS,1116-SHS clocks failed .................................................................... 3-50
0192 - 1114-PHS, 1116-PHS clocks failed ..................................................................................... 3-51
0193 - 1114-PHS, 1116-PHS,1116-SHS clks failed........................................................................ 3-52
0194 - 1114-PHS, 1114-SHS clocks failed...................................................................................... 3-53
0195 - 1114-PHS, 1114-SHS,1116-SHS clks failed ........................................................................ 3-54
0196 - 1114-PHS, 1114-SHS,1116-PHS clks failed........................................................................ 3-55
0197 - All high speed clocks have failed ..................................................................................... 3-56
0201 - REPT-LKF: remote NE loopback....................................................................................... 3-56
0202 - REPT-LKF: HWP - too many link interrupts................................................................... 3-57
0203 - REPT-LKF: lost data............................................................................................................ 3-57
0204 - REPT-LKF: XER - ERM threshold exceeded.................................................................... 3-58
0205 - REPT-LKF: APF - lvl-2 T1 expd (ready)........................................................................... 3-58
0206 - REPT-LKF: APF - lvl-2 T1 expd (not ready) .................................................................... 3-58
0207 - REPT-LKF: APF - lvl-2 T3 expired .................................................................................... 3-59
0208 - REPT-LKF: APF - lvl-2 T2 expired .................................................................................... 3-59
0209 - REPT-LKF: APF - failed proving period .......................................................................... 3-59
0210 - REPT-LKF: OSA - received SIO......................................................................................... 3-60
0211 - REPT-LKF: OSA - received SIN......................................................................................... 3-60
0212 - REPT-LKF: OSA - received SIE ......................................................................................... 3-60
0213 - REPT-LKF: OSA - received SIOS....................................................................................... 3-61
0214 - REPT-LKF: ABN - rcvd 2 of 3 invalid BSN...................................................................... 3-61
0215 - REPT-LKF: ABN - rcvd 2 of 3 invalid FIB........................................................................ 3-61
0216 - REPT-LKF: remote congestion timeout............................................................................ 3-62
0217 - REPT-LKF: XDA - excess acknowledge delay ................................................................ 3-62
0218 - REPT-LKF: COO - rcvd changeover order ...................................................................... 3-63
0219 - REPT-LKF: false congestion restart .................................................................................. 3-64
0220 - REPT-LKF: MTP link restart delayed............................................................................... 3-64
0222 - REPT-LKF: remote FE loopback........................................................................................ 3-65
0224 - REPT-LKF: link test failed.................................................................................................. 3-65
0230 - REPT-LKF: local blocked - thermal................................................................................... 3-65
0232 - REPT-LKF: remote blocked................................................................................................ 3-66
0233 - REPT-LINK-MANUAV: local blocked ............................................................................. 3-66
0234 - REPT-LKF: RMI remote inhibited..................................................................................... 3-66
0235 - REPT-LINK-MGTINH: local inhibited............................................................................. 3-67
0236 - REPT-LKF: not aligned....................................................................................................... 3-67
0237 - REPT-LKF: LM Timer NO-CREDIT expired ................................................................... 3-68
0238 - REPT-LKF: XDA-Timer NO-RESPONSE expired .......................................................... 3-69
0239 - REPT-LKF: MBL-local processor outage.......................................................................... 3-69
v
0240 - REPT-LKF: rcvd remote processor outage....................................................................... 3-69
0241 - REPT-LKF: rcvd remote out of service............................................................................. 3-70
0242 - REPT-LKF:rcvd remote protocol error ............................................................................. 3-70
0243 - REPT-LKF:rcvd remote mgmt inititated.......................................................................... 3-70
0244 - REPT-LKF: FAC – DS1/E1 LOS failure............................................................................ 3-71
0245 - REPT-LKF: FAC – DS1/E1 LOF failure............................................................................ 3-71
0246 - REPT-LKF: FAC – DS1/E1 LCD failure ........................................................................... 3-72
0247 - REPT-LKF: XER - ISERM threshold exceeded ................................................................ 3-72
0248 - DDL Unstable ...................................................................................................................... 3-72
0249 - DDL Stable ........................................................................................................................... 3-73
0261 - MPS unavailable.................................................................................................................. 3-73
0262 - GTT Duplicate Actn processing stopped......................................................................... 3-74
0276 - Insufficient HW for IP7 provisioning............................................................................... 3-74
0277 - AS Unavailable .................................................................................................................... 3-75
0283 - LNP Ported LRNs approaching Feat. Cap. ..................................................................... 3-75
0285 - LNP Ported NPAs approaching Feat. Cap. ..................................................................... 3-76
0287 - RTDB Table Level 2 FAK Cap Exceeded.......................................................................... 3-76
0288 - RTDB Table Level 1 FAK Cap exceeded .......................................................................... 3-77
0291 - GLS is at minimum service limit....................................................................................... 3-77
0292 - GLS is not available ............................................................................................................ 3-78
0297 - Incorrect port configuration .............................................................................................. 3-79
0300 - TVG Grant Failure............................................................................................................... 3-79
0308 - Node isolated due to SLK failures .................................................................................... 3-81
0313 - DPC is prohibited................................................................................................................ 3-82
0318 - REPT-LKSTO: Link set prohibited.................................................................................... 3-83
0319 - REPT-MTPLP-DET: Circ rte det(cong) ............................................................................. 3-84
0320 - REPT-MTPLP-SUST: Sustained circ rt(cong) .................................................................. 3-85
0325 - DPC subsystem is blocked................................................................................................. 3-86
0326 - DPC subsystem is prohibited ............................................................................................ 3-86
0330 - System SCCP TPS Threshold exceeded ........................................................................... 3-87
0331 - SCCP is not available.......................................................................................................... 3-88
0332 - DPC Subsystem is prohibited and blocked..................................................................... 3-89
0334 - DPC Subsystem is Abnormal ............................................................................................ 3-89
0336 - LIM(s) have been denied SCCP service ........................................................................... 3-90
0338 - X-LIST space full-entry(s) discarded................................................................................ 3-91
0341 - OAP Unavailable................................................................................................................. 3-92
0342 - SEAS UAL unavailable....................................................................................................... 3-94
0343 - SEAS X.25 Link unavailable .............................................................................................. 3-95
0345 - All SEAS UAL sessions unavailable................................................................................. 3-96
0348 - SEAS is at min service limit ............................................................................................... 3-97
0349 - SEAS unavailable ................................................................................................................ 3-99
0350 - OAP terminals inhibited .................................................................................................. 3-102
0354 - One OAP terminal unavailable....................................................................................... 3-104
vi
0356 - LSMS is unavailable.......................................................................................................... 3-106
0358 - LSMS connection unavailable ......................................................................................... 3-108
0360 - EMS Agent unavailable.................................................................................................... 3-110
0362 - LSMS is at min. service limit ........................................................................................... 3-111
0367 - Temp Key(s) expiring soon .............................................................................................. 3-112
0368 - Temp Key(s) have expired ............................................................................................... 3-112
0369 - REPT-T1F:FAC-T1 unavailable........................................................................................ 3-113
0370 - Critical Platform Failure(s) .............................................................................................. 3-113
0371 - Critical Application Failure(s)......................................................................................... 3-113
0372 - Major Platform Failure(s)................................................................................................. 3-114
0373 - Major Application Failure(s) ........................................................................................... 3-114
0376 - REPT-T1F:FAC-T1 LOS failure ........................................................................................ 3-115
0377 - REPT-T1F:FAC-T1 LOF failure........................................................................................ 3-115
0378 - REPT-T1F:FAC-T1 Remote Alarm .................................................................................. 3-115
0379 - REPT-T1F:FAC-T1 Alarm................................................................................................. 3-115
0381 - REPT-E1F:FAC-E1 LOS failure ........................................................................................ 3-116
0382 - REPT-E1F:FAC-E1 LOF failure........................................................................................ 3-116
0383 - REPT-E1F:FAC-E1 AIS detected...................................................................................... 3-116
0384 - REPT-E1F:FAC-E1 Far End Failure................................................................................. 3-116
0385 - REPT-E1F:FAC-E1 10E-3 BER failed............................................................................... 3-117
0387- REPT-E1F:FAC-E1 unavailable......................................................................................... 3-117
0389 - Card Responding Normally ............................................................................................ 3-117
0390 - Illegal Address Error ........................................................................................................ 3-117
0391 - Card not responding Error .............................................................................................. 3-118
0392 - OA&M IP Security feature is OFF .................................................................................. 3-118
0395 - INP Subsystem is not available....................................................................................... 3-119
0396 - INP Subsystem is disabled .............................................................................................. 3-119
0403 - 1114 E1/T1 clock requires TDM-GTI.............................................................................. 3-120
0404 - 1116 E1/T1 clock requires TDM-GTI.............................................................................. 3-120
0405 - 1114, 1116 E1/T1 clock requires TDM-GTI .................................................................... 3-121
0406 - 1114 Clock selection mismatch ........................................................................................ 3-121
0407 - 1116 Clock selection mismatch ........................................................................................ 3-122
0408 - 1114, 1116 Clock selection mismatch .............................................................................. 3-123
0422 - Insufficient extended memory ........................................................................................ 3-124
0424 - LNP Subsystem is not available...................................................................................... 3-124
0427 - LNP Subsystem degraded, card(s) abnormal ............................................................... 3-125
0428 - INP Subsystem degraded, card(s) abnormal ................................................................ 3-125
0429 - ATINPQ Subsystem degraded, card(s) abnormal ........................................................ 3-126
0435 - LNP Subsystem is disabled ............................................................................................. 3-126
0436 - LNP ACG node overload................................................................................................. 3-126
0437 - System SCCP TPS Capacity Exceeded ........................................................................... 3-127
0438 - Degraded Mode, Invalid OAM HW config................................................................... 3-127
0441 - Incorrect MBD - CPU........................................................................................................ 3-128
vii
0442 - RTDB database capacity is 90% full................................................................................ 3-128
0443 - RTDB database corrupted................................................................................................ 3-133
0446 - RTDB database capacity is 80% full................................................................................ 3-134
0449 - RTDB resynchronization in progress ............................................................................. 3-138
0450 - Invalid HW for Integrated GLS ...................................................................................... 3-139
0451 - RTDB reload required....................................................................................................... 3-139
0452 - Exceeded Service Error Threshold Lvl 1........................................................................ 3-139
0453 - Exceeded Service Error Threshold Lvl 2........................................................................ 3-140
0455 - EIR Subsystem is not available ....................................................................................... 3-141
0456 - EIR Subsystem is disabled ............................................................................................... 3-142
0460 - EIR Subsystem degraded, card(s) abnormal ................................................................. 3-142
0466 - STC Network Unavailable ............................................................................................... 3-143
0468 - All STC Networks Unavailable....................................................................................... 3-143
0469 - All STC Cards Unavailable .............................................................................................. 3-143
0473 - EROUTE System Capacity Exceeded............................................................................. 3-144
0482 - Card(s) have been denied EROUTE service.................................................................. 3-144
0483 - DEIR System is not available........................................................................................... 3-144
0484 - DEIR System normal, card(s) abnormal ........................................................................ 3-144
0485 - DEIR System is available ................................................................................................. 3-145
0486 - DEIR Threshold - Level1 exceeded................................................................................. 3-145
0487 - DEIR System Threshold - Level2 exceeded................................................................... 3-145
0488 - DEIR Threshold Condition Cleared ............................................................................... 3-146
0489 - DEIR capacity exceeded................................................................................................... 3-146
0490 - DEIR normal ...................................................................................................................... 3-146
0491 - Connection TPS exceeded................................................................................................ 3-146
0492 - Connection TPS normal ................................................................................................... 3-147
0493 - Diameter Connection Down............................................................................................ 3-147
0494 - Diameter Connection UP ................................................................................................. 3-147
0495 - Diameter Connection Closed .......................................................................................... 3-148
0496 - DEIR System is removed.................................................................................................. 3-148
0497 - REPT-J1F:FAC-J1 LOS failure .......................................................................................... 3-148
0498 - REPT-J1F:FAC-J1 LOF failure .......................................................................................... 3-148
0499 - REPT-J1F:FAC-J1 Remote Alarm .................................................................................... 3-149
0501 - OAM ITT sample Minor Alarm ...................................................................................... 3-149
0502 - OAM ITT sample Minor Alarm ...................................................................................... 3-149
0503 - OAM ITT sample Critical Alarm .................................................................................... 3-150
0504 - REPT-J1F:FAC-J1 Alarm................................................................................................... 3-150
0505 - RRCVRY-J1F:FAC-J1 available ........................................................................................ 3-150
0506 - REPT-J1F:FAC-J1 unavailable.......................................................................................... 3-150
0514 - Standby MASP inhibited.................................................................................................. 3-151
0517 - Degraded Mode - multiple cards failed......................................................................... 3-151
0518 - Measurements subsystem unavailable .......................................................................... 3-152
0520 - Frame power usage reached LVL3 ................................................................................. 3-152
viii
0521 - Frame power usage reached LVL2 ................................................................................. 3-153
0528 - Service is not available ..................................................................................................... 3-153
0529 - Service is disabled............................................................................................................. 3-154
0534 - RTX is prohibited .............................................................................................................. 3-154
0537 - Ethernet error threshold exceeded ................................................................................. 3-155
0539 - Ethernet Interface Down .................................................................................................. 3-159
0541 - MSU cksum error threshold exceeded........................................................................... 3-160
0546 - SEAS Terminal Unavailable............................................................................................. 3-163
0547 - Service degraded............................................................................................................... 3-165
0548 - GTT HexTree DB corrupted. TPS derated ..................................................................... 3-165
0549 - GTT HexTree DB incoherent. TPS derated .................................................................... 3-166
0550 - GTT HexTree DB alarm cleared ...................................................................................... 3-166
0551 - V-Flex Subsystem is not available................................................................................... 3-166
0552 - V-Flex Subsystem is disabled .......................................................................................... 3-166
0556 - V-Flex Subsystem degraded, card(s) abnormal ............................................................ 3-167
0561 - Can't establish Hi Bit rate;All HW OK........................................................................... 3-167
0563 - IMT Bit rate mismatch detected...................................................................................... 3-168
0565 - ATINPQ Subsystem is not available .............................................................................. 3-169
0566 - ATINPQ Subsystem is disabled ...................................................................................... 3-169
0570 - Incompatible flash image for sys rel............................................................................... 3-170
0573 - BERT Test Failed................................................................................................................ 3-173
0575 - Card type not HIPR2 ........................................................................................................ 3-173
0576 - All FC Network Unavailable........................................................................................... 3-174
0588 - FC Port De-activated......................................................................................................... 3-174
0592 - AIQ Subsystem is not available ...................................................................................... 3-174
0593 - AIQ: Subsystem is disabled ............................................................................................. 3-175
0598 - Subsystem degraded, card(s) abnormal ........................................................................ 3-175
0619 - SIP SYSTEM is not available............................................................................................ 3-176
0620 - SIP SYSTEM is available .................................................................................................. 3-176
0622 - SIP Threshold - Level1...................................................................................................... 3-176
0623 - SIP Threshold - Level2...................................................................................................... 3-177
0624 - SIP Threshold Condition Cleared................................................................................... 3-177
0625 - SIP SYSTEM normal, card(s) abnormal ......................................................................... 3-177
0626 - SIP Threshold Level Critical ............................................................................................ 3-178
0627 - SFLOG SYSTEM is not available..................................................................................... 3-178
0628 - SFLOG SYSTEM is available ........................................................................................... 3-178
0629 - SFLOG SYSTEM is removed ........................................................................................... 3-179
0630 - Throttle Threshold - exceeded......................................................................................... 3-179
0631 - Throttle Threshold - cleared ............................................................................................ 3-179
0632 - Alarm Threshold - exceeded ........................................................................................... 3-180
0633 - Alarm Threshold - cleared ............................................................................................... 3-181
0901 - Card DB load timeout, check GLS SS............................................................................. 3-181
0903 - IP Link A is down ............................................................................................................. 3-182
ix
0905 - IP Link B is down .............................................................................................................. 3-183
0908 - HW cannot support purchased TPS rate ....................................................................... 3-185
0911 - Dynamic database is inconsistent ................................................................................... 3-185
UIMs ....................................................................................................................................................... 3-187
1000 - MTP rcvd UPU - user part is not SCCP ......................................................................... 3-187
1020 - IARCDPN NPP Service is off .......................................................................................... 3-187
1021 - IARCGPN NPP Service is off .......................................................................................... 3-188
1022 - System Meas. limit exceeded for LSONISMT............................................................... 3-188
1026 - System Meas Limit exceeded for LSORIGNI................................................................ 3-189
1027 - System Meas Limit exceeded for LSDESTNI ................................................................ 3-189
1028 - System Meas. Limit exceeded for ORIGNI/NINC ...................................................... 3-189
1030 - Inh EIR SS request already outstanding ........................................................................ 3-189
1031 - Failure Inhibiting EIR SS .................................................................................................. 3-190
1032 - Set ETS Mismatch.............................................................................................................. 3-190
1061 - Meas sync not allowed from old version....................................................................... 3-190
1062 - String Data Dump ............................................................................................................. 3-190
1063 - SCCP screen set is too large ............................................................................................. 3-191
1072 - SLTC failure: no response ................................................................................................ 3-191
1075 - MTP: link bypassed SLT phase ....................................................................................... 3-192
1080 - disk measurement status unreadable............................................................................. 3-193
1081 - MTP: Changeback T5 timeout......................................................................................... 3-193
1082 - Amem single bit error report........................................................................................... 3-194
1083 - REPT COND: system alive .............................................................................................. 3-194
1086 - LFS test aborted with OAM switchover ........................................................................ 3-194
1087 - MTP RSTRT rcvd unexpected user traffic ..................................................................... 3-194
1088 - REPT-MTP-RSTRT MTP Restart started........................................................................ 3-195
1089 - RCVRY-MTP-RSTRT MTP Restart completed .............................................................. 3-195
1095 - ITU GWY:GRS buffer full................................................................................................. 3-195
1096 - ITU GWY:RSC buffer full................................................................................................. 3-196
1097 - ITU GWY:CGB buffer full ................................................................................................ 3-196
1098 - Unexpected disk access timeout ..................................................................................... 3-196
1099 - String Data Dump ............................................................................................................. 3-196
1101 - SDRAM Single Bit Error Report ..................................................................................... 3-197
1104 - IP Connection Failed......................................................................................................... 3-197
1105 - REPT EVT:IMT GPL reloading........................................................................................ 3-198
1106 - REPT COND:IMT GPL reloading ................................................................................... 3-198
1114 - Database BACKUP started............................................................................................... 3-198
1115 - Database RESTORE started.............................................................................................. 3-198
1116 - Database action ended - OK............................................................................................. 3-199
1117 - Database action ended - FAIL.......................................................................................... 3-199
1118 - TOD change affects MEAS collection ............................................................................ 3-199
1119 - Cards out of phase with flash procedure ...................................................................... 3-199
1120 - TRBL Queue is full:elements overwritten ..................................................................... 3-200
x
1124 - SIP: Dgts truncated in 302 response ............................................................................... 3-200
1132 - SLAN DLK ping test completed ..................................................................................... 3-200
1133 - Diameter msg decode failed ............................................................................................ 3-201
1134 - Diameter msg encode Failed ........................................................................................... 3-201
1135 - Invalid diameter Msg received........................................................................................ 3-201
1136 - Invalid Diameter Msg length........................................................................................... 3-202
1137 - Diameter AVP Decode Fail .............................................................................................. 3-202
1138 - Connection Refused .......................................................................................................... 3-202
1139 - DEIROPTS: DEIR Global Response is ON..................................................................... 3-203
1140 - DEIROPTS: DEIR Global Response is OFF.................................................................... 3-203
1141 - AIN INP Qry rejected: AINPQ is OFF ........................................................................... 3-203
1142 - GWS Strip Stop Action Failed ......................................................................................... 3-204
1143 - GTT(FLOBR) failure: duplicate settype ......................................................................... 3-204
1144 - GTT(FLOBR) warning: duplicate settype...................................................................... 3-204
1145 - MBR decoding failed ........................................................................................................ 3-205
1146 - REPT-XLST-TIMO: X-LIST entry expired ...................................................................... 3-205
1149 - SLK Level-3 T19 timer expired........................................................................................ 3-206
1150 - SLK Inhibit Denied ........................................................................................................... 3-206
1151 - SLK Inhibit Response Timeout ........................................................................................ 3-207
1152 - SLK Uninhibit Denied ...................................................................................................... 3-207
1153 - SLK Uninhibit Response Timeout................................................................................... 3-207
1154 - MSU received threshold exceeded.................................................................................. 3-207
1155 - MSU-rejected threshold exceeded .................................................................................. 3-208
1156 - Minor congestion event detected.................................................................................... 3-208
1157 - Major congestion event detected .................................................................................... 3-208
1158 - Minor HIPR2 switching capacity reached ..................................................................... 3-209
1159 - Major HIPR2 switching capacity reached...................................................................... 3-209
1164 - Inh LNP SS request already outstanding....................................................................... 3-209
1166 - ACG Node Overload Level Change............................................................................... 3-209
1167 - SIP connection established............................................................................................... 3-210
1168 - SIP connection terminated ............................................................................................... 3-210
1170 - OAMHC Meas transition complete. ............................................................................... 3-210
1171 - Schd UI Rpt disbld-link cnt exceeds 700........................................................................ 3-211
1172 - REPT-OVSZMSG: MTP MSU too large to rte................................................................ 3-211
1174 - Inh INP SS request alrdy outstanding............................................................................ 3-211
1176 - Unexpected DB version - Using UDT ............................................................................ 3-212
1185 - GTI input clock anomalies detected ............................................................................... 3-212
1186 - Meas data load failure: old version ................................................................................ 3-212
1187 - Table Checksum Mismatch .............................................................................................. 3-213
1188 - DB Subset Checksum Mismatch ..................................................................................... 3-213
1194 - IP Connection Refused, RHOST mismatch ................................................................... 3-213
1197 - IP Connection refused ...................................................................................................... 3-214
1198 - IP Connection, Cannot resolve RHOST(S)..................................................................... 3-214
xi
1199 - LNP DTH Measurements Discarded for DPC .............................................................. 3-215
1200 - INW ALT card as first to be preloaded .......................................................................... 3-215
1201 - INW MAIN card as last to be reset................................................................................. 3-216
1202 - INW Asserted DDL inhibition ........................................................................................ 3-216
1203 - INW Card reset command issued................................................................................... 3-216
1204 - INW Waiting for card loading validation...................................................................... 3-216
1205 - INW Detected card loaded .............................................................................................. 3-217
1206 - INW Detected card reset or removed............................................................................. 3-217
1207 - INW Allowed card to skip DDL inhibited .................................................................... 3-217
1208 - INW Removed DDL inhibition ....................................................................................... 3-217
1209 - INW Need to reset/remove/inhibit card...................................................................... 3-218
1210 - INW Card failed to reset .................................................................................................. 3-218
1211 - INW Failed to assert DDL inhibition.............................................................................. 3-218
1212 - INW Failed to remove DDL inhibition .......................................................................... 3-218
1213- INW Card failed to DDL crossload ................................................................................. 3-219
1214 - INW Allowed card to DDL crossload ............................................................................ 3-219
1233 - MTP Invalid ITU TFR RCVD .......................................................................................... 3-219
1234 - LNP Day Meas. Discarded for NPANXX ...................................................................... 3-220
1235 - Unable to connect Primary SFLOG Server .................................................................... 3-220
1236 - Unable to connect both SFLOG Servers......................................................................... 3-220
1237 - Dynamic database audit not current .............................................................................. 3-221
1238 - Full LNP database reload initiated................................................................................. 3-221
1239 - Ntwrk Card Reload Failed during Upg......................................................................... 3-222
1240 - MAP SCCP Validation Fail .............................................................................................. 3-222
1241 - SCCP Card logging capacity exceeded .......................................................................... 3-223
1251 - Measurements data copy failure..................................................................................... 3-223
1252 - Report generation failure ................................................................................................. 3-223
1253 - Report transfer failure FTP Server.................................................................................. 3-224
1254 - Scheduled transfer failure................................................................................................ 3-224
1257 - DB restore has cleared and Disabled PDS ..................................................................... 3-224
1298 - SIP message decode failed ............................................................................................... 3-224
1305 - MTP rcvd UPU - User SCCP, Cause invalid.................................................................. 3-225
1306 - GSMOPTS: EIR Global Response is ON ........................................................................ 3-225
1307 - GSMOPTS: EIR Global Response is OFF ....................................................................... 3-226
1308 - Updates inhibited: Target-Cell CRC Fail ....................................................................... 3-226
1309 - Updates inhibited: Source-Cell CRC Fail ...................................................................... 3-226
1310 - System Meas. Limit exceeded for LRN.......................................................................... 3-227
1311 - System Meas. Limit exceeded for NPANXX ................................................................. 3-227
1312 - LSS: Interrogation Type missing ..................................................................................... 3-227
1313 - LSS: Invalid Interrogation Type ...................................................................................... 3-228
1314 - LSS: MSISDN missing ...................................................................................................... 3-228
1315 - ICNP: Response PC prohibited....................................................................................... 3-228
1316 - ICNP: Invalid Message received..................................................................................... 3-228
xii
1317 - ICNP: Response PC unknown ........................................................................................ 3-229
1318 - ICNP: OPC/DPC correlation problem .......................................................................... 3-229
1319 - ICNP: IDCA not reachable............................................................................................... 3-229
1320 - FPT value unprovisioned for frame ............................................................................... 3-230
1321 - Eagle RTDB Birthdate Mismatch .................................................................................... 3-230
1322 - Eagle RTDB Levels Invalid .............................................................................................. 3-230
1323 - Eagle/Elap TN Quantity Mismatch ............................................................................... 3-231
1324 - Eagle/Elap NPANXX Quantity Mismatch.................................................................... 3-231
1325 - Eagle/Elap LRN Quantity Mismatch ............................................................................ 3-231
1326 - Eagle RTDB Depth Alert .................................................................................................. 3-231
1331 - IP Route Table Entry Conflict .......................................................................................... 3-232
1333 - UA RCVD MSG DISCARDED ........................................................................................ 3-232
1334 - UA TX MSG DISCARDED .............................................................................................. 3-235
1335 - Table Information.............................................................................................................. 3-236
1336 - UA ERROR MSG RECEIVED.......................................................................................... 3-236
1340 - REPT COND: TRBL resynch required ........................................................................... 3-237
1345 - CRD Auto-Clear Sent to All MTP Cards ....................................................................... 3-238
1347 - IS-41 Digits - Bad Encoding Scheme .............................................................................. 3-238
1348 - IS-41 Number of dgts exceeds the maximum ............................................................... 3-238
1349 - MSU invalid size – discarded.......................................................................................... 3-239
1350 - Discrd Rcvd Lrg MSU CTRL-FEAT Off ......................................................................... 3-239
1351 - Discrd Trans Lrg MSU Unsupported SLK..................................................................... 3-240
1352 - Discrd Rcvd Lrg MSU Unsptd Outbnd SLK................................................................. 3-240
1353 - DTA Bypassed for Rcvd Lrg MSU.................................................................................. 3-241
1354 - STPLAN Copy Bypassed for Lrg MSU.......................................................................... 3-241
1356 - EXT BERT terminated with OAM switchover .............................................................. 3-242
1357 - Negotiation at 100Mbps/Full Duplex failed................................................................. 3-242
1358 - MSU discarded - too big after MTP conv....................................................................... 3-242
1359 - SCCP Looping Detected................................................................................................... 3-243
1360 - Inv SR-5129 msg rcvd, Bad Src........................................................................................ 3-244
1361 - Inv SR-5129 msg rcvd, Bad Dst. ...................................................................................... 3-244
1362 - Inv SR-5129 msg rcvd, Bad Ver........................................................................................ 3-245
1363 - SR-5129 Err Msg rcvd Err Code 1(Bad Src) ................................................................... 3-245
1364 - SR-5129 Err Msg rcvd Err Code 2(Bad Dst)................................................................... 3-245
1365 - SR-5129 Err Msg rcvd Err Code 3(Bad Ver)................................................................... 3-245
1366 - SR-5129 Err Msg rcvd Err Code Other........................................................................... 3-246
1367 - SOIP connection failed. .................................................................................................... 3-246
1368 - Inv SR-5129 msg rcvd, Other........................................................................................... 3-246
1369 - ISUP IAM decode failed................................................................................................... 3-247
1370 - ISUP IAM Cld Pty decode failed .................................................................................... 3-247
1371 - ISUP encode Failed ........................................................................................................... 3-247
1372 - SLTC Failure-SLTM not sent, Invalid SIO ..................................................................... 3-248
1373 - TFC Generated for Congested Link ............................................................................... 3-248
xiii
1374 - SMS B-Party address decode failed................................................................................ 3-249
1375 - SMS B-party Failed to modify TCAP MSU ................................................................... 3-249
1376 - SMS Failed to modify B-Party digits .............................................................................. 3-250
1378 - Inh VFlex SS request already outstanding .................................................................... 3-251
1379 - Failure Inhibiting VFlex SS .............................................................................................. 3-251
1380 - VFLEX: No RN digits provisioned ................................................................................. 3-251
1381 - VFlex: CD entry not found............................................................................................... 3-252
1382 - Too many digits for DRA parameter.............................................................................. 3-252
1383 - SLTC Failed: No route to APC on linkset ...................................................................... 3-252
1392 - IDPRCDPN(X) NPP SERVICE is OFF............................................................................ 3-253
1393 - IDPRCGPN NPP SERVICE is OFF ................................................................................. 3-254
1394 - Flushing undelivered MSUs............................................................................................ 3-255
1395 - Inh ATINPQ SS request alrdy outstanding ................................................................... 3-256
1396 - Failure Inhibiting ATINPQ SS......................................................................................... 3-256
1407 - Unexpected SI in TIF Stop Action................................................................................... 3-256
1408 - TIF: Modified MSU too large to route............................................................................ 3-257
1410 - MOSMS: Migrated Subscriber with no entity............................................................... 3-258
1411 - TIF CgPN NS Failure: CC mismatch in DN .................................................................. 3-258
1416 - MAP Missing Mandatory Parameters ........................................................................... 3-258
1417 - PublicKey doesn’t match known-host file..................................................................... 3-259
1424 - IMT A [B] requested to re-align at LOW [HIGH] Rate................................................ 3-259
1425 - SMS A-party Address decode failed .............................................................................. 3-260
1426 - S-Port: Missing GRN for srvc prtd subs ........................................................................ 3-260
1427 - IAR CdPN parameter invalid or not found .................................................................. 3-260
1428 - IAR CgPN parameter invalid or not found................................................................... 3-261
1429 - IAR TRIGTYPE invalid or not found ............................................................................. 3-261
1430 - IAR CdPN parameter encoding failed........................................................................... 3-261
1431 - IAR CgPN parameter encoding failed ........................................................................... 3-262
1433 - AIQ: Inhibit request already pending ............................................................................ 3-262
1434 - AIQ: Failure Inhibiting SS................................................................................................ 3-262
1435 - AIQ: TriggerType not provisioned ................................................................................. 3-262
1436 - AIQ: Unsupported Digits(Dialed) length...................................................................... 3-263
1437 - IMT [A|B]: Rate change not initiated ............................................................................ 3-263
1439 - SIP card exceeded threshold TPS.................................................................................... 3-264
1440 - G-Flex MLR: Op with bad MSISDN skipped................................................................ 3-264
1441 - IP Info mismatch, card reset required ............................................................................ 3-264
1442 - Invalid EMP SCR Message Received ............................................................................. 3-265
1445 - LNP Day Meas. Discarded for LRN ............................................................................... 3-265
1449 - Binding Failed for screen set: <screen set name>......................................................... 3-265
1450 - IDPRCDPN CDPN Encoding Failed.............................................................................. 3-266
1451 - IDPRCGPN CGPN Encoding Failed .............................................................................. 3-266
1452 - Invalid IP Address from SCTP Heartbeat Response.................................................... 3-267
1453 - EE Collection started ........................................................................................................ 3-267
xiv
1454 - EE Collection end.............................................................................................................. 3-267
1455 - EE Queue full, Packets Dropped..................................................................................... 3-268
1456 - Hub Congested, Packets Dropped ................................................................................. 3-268
1457 - GEDTI Port Enabled ......................................................................................................... 3-268
1458 - GEDTI Port Disabled ........................................................................................................ 3-269
1459 - TCP Connection lost b/w IPSM and EEPC................................................................... 3-269
1460 - GWS Duplicate Stop Action Failed ................................................................................ 3-269
1461 - Link status on card needs re-sync................................................................................... 3-269
1462 - EE not Configured............................................................................................................. 3-270
1463 - ENUM connection established........................................................................................ 3-270
1464 - ENUM connection terminated ........................................................................................ 3-270
1466 - ENUM Dflt Prof & query type mismatch...................................................................... 3-270
1467 - ENUM msg decode failed................................................................................................ 3-271
1468 - ENUM rcvd invalid msg.................................................................................................. 3-271
1469 - ENUM request rejected .................................................................................................... 3-271
1471 - ENUM matching prof for qry not found ....................................................................... 3-272
1472 - SCTP Buffer full timer expired, Restart ......................................................................... 3-272
1473 - Unable to connect to socket ............................................................................................. 3-272
1475 - TOBR Multiple Comp: Translation found ..................................................................... 3-273
1476 - TCAPMulComp: Dup Opcode MSU discarded ........................................................... 3-273
1491 - Terminal enabled............................................................................................................... 3-273
1492 - Terminal failed................................................................................................................... 3-274
1493 - SSH Host Keys Regenerated............................................................................................ 3-274
1494 - SSH Host Keys Loaded .................................................................................................... 3-275
A UAM Balancing Matrix
AIQ System Alarms.................................................................................................................................. A-1
ATINP System Alarms ............................................................................................................................. A-1
Card Alarms .............................................................................................................................................. A-2
CDT (Customer Defined Trouble) Alarms ............................................................................................ A-6
Clock (Holdover Clock) Alarms ............................................................................................................. A-6
Clock System Alarms ............................................................................................................................... A-7
DCM Alarms.............................................................................................................................................. A-8
DLK Alarms............................................................................................................................................... A-8
DPC Alarms............................................................................................................................................... A-9
DPC System Alarms ............................................................................................................................... A-10
DSM Alarms ............................................................................................................................................ A-11
E1 Port Alarms ........................................................................................................................................ A-11
EIR Alarms............................................................................................................................................... A-12
ENET System Alarms............................................................................................................................. A-12
ENUM System Alarms........................................................................................................................... A-13
EROUTE Alarms..................................................................................................................................... A-13
Ethernet Error Threshold Alarms......................................................................................................... A-14
xv
Fast Copy System Alarms...................................................................................................................... A-14
Frame Alarms.......................................................................................................................................... A-14
Fuse Alarms............................................................................................................................................. A-15
GLS Alarms.............................................................................................................................................. A-15
GPL Alarms ............................................................................................................................................. A-16
Group Broadcast Alarms ....................................................................................................................... A-16
GTT Alarms ............................................................................................................................................. A-16
HS Clock System Alarms....................................................................................................................... A-17
IMT Bus Alarms ...................................................................................................................................... A-18
IMT System Alarms................................................................................................................................ A-18
INP System Alarms ................................................................................................................................ A-19
IP7CONN Alarms................................................................................................................................... A-19
IP7 Alarms ............................................................................................................................................... A-20
Linkset Alarms ........................................................................................................................................ A-20
LNP System Alarms ............................................................................................................................... A-21
LSMS Connection Alarms ..................................................................................................................... A-21
LSMS System Alarms ............................................................................................................................. A-22
MCPM Alarms ........................................................................................................................................ A-22
MEAS System Alarms ............................................................................................................................ A-23
MPS (ELAP/EPAP) Alarms .................................................................................................................. A-23
MPS Alarm Support ............................................................................................................................... A-24
RTX System Alarms................................................................................................................................ A-24
SCCP Service Alarms ............................................................................................................................. A-25
SCCP System Alarms ............................................................................................................................. A-25
SCTP Retransmit Alarms....................................................................................................................... A-26
SEAS OAP Alarms.................................................................................................................................. A-26
SEAS System Alarms.............................................................................................................................. A-27
SEAS X25 Alarms.................................................................................................................................... A-27
Security Log Alarm................................................................................................................................. A-28
Security System Alarms......................................................................................................................... A-28
SFLOG System Alarms .......................................................................................................................... A-29
SLK Alarms.............................................................................................................................................. A-29
STPLAN Alarms ..................................................................................................................................... A-33
<subsystem> System Alarms................................................................................................................ A-34
System Alarms ........................................................................................................................................ A-34
System GPL Alarms................................................................................................................................ A-35
T1 Port Alarms ........................................................................................................................................ A-35
Terminal Alarms ..................................................................................................................................... A-36
V-Flex System Alarms ............................................................................................................................ A-36
X-LIST Alarms......................................................................................................................................... A-36
B Unsolicited Output Message Groups
Application Subsystem Unsolicited Output Message Group ............................................................ B-1
xvi
Card Unsolicited Output Message Group ............................................................................................ B-7
Clock Unsolicited Output Message Group ......................................................................................... B-11
Database Unsolicited Output Message Group ................................................................................... B-13
GTT Unsolicited Output Message Group ........................................................................................... B-13
Gateway Screening Unsolicited Output Message Group ................................................................. B-17
Link Maintenance Unsolicited Output Message Group ................................................................... B-19
Measurements Maintenance Unsolicited Output Message Group ................................................. B-26
Monitor Unsolicited Output Message Group..................................................................................... B-27
MPS Unsolicited Output Message Group........................................................................................... B-28
Program Update Unsolicited Output Message Group...................................................................... B-29
SEAS Maintenance Unsolicited Output Message Group.................................................................. B-29
Security Administration Unsolicited Output Message Group ........................................................ B-30
SLAN Maintenance Unsolicited Output Message Group ................................................................ B-30
System Maintenance Unsolicited Output Message Groups ............................................................. B-31
UIM Redirect Unsolicited Output Message Group ........................................................................... B-37
C Auto-Inhibit Hardware Verification Codes
Hardware Verification Codes in UAMs................................................................................................. C-1
xvii
xviii
List of Figures
2-1 Output Message Format............................................................................................................. 2-23-1 Card LEDs.................................................................................................................................. 3-31
xix
xx
List of Tables
1-1 Admonishments........................................................................................................................... 1-23-1 Maintenance Activity Hierarchy............................................................................................... 3-83-2 Maintenance Activity Hierarchy............................................................................................. 3-123-3 Maximum Sockets/Associations per Card............................................................................ 3-753-4 See (DCM/DSM/EDCM/SSEDCM) Ethernet Error Statistics......................................... 3-1563-5 GEI (E5-ENET/E5-ENET-B) Ethernet Error Statistics....................................................... 3-1583-6 CAUSE Parameters................................................................................................................. 3-2213-7 SG Received Messages Discarded........................................................................................ 3-2333-8 SG Messages Discarded in the Transmit Path..................................................................... 3-235A-1 AIQ System Alarms.................................................................................................................... A-1A-2 ATINP System Alarms............................................................................................................... A-2A-3 Card Alarms................................................................................................................................. A-2A-4 CDT (Customer Defined Trouble) Alarms.............................................................................. A-6A-5 Clock (Holdover) Alarms........................................................................................................... A-6A-6 Clock System Alarms.................................................................................................................. A-7A-7 DCM Alarms................................................................................................................................ A-8A-8 DLK Alarms................................................................................................................................. A-8A-9 DPC Alarms................................................................................................................................. A-9A-10 DPC System Alarms................................................................................................................. A-10A-11 DSM Alarms.............................................................................................................................. A-11A-12 E1 Port Alarms.......................................................................................................................... A-11A-13 EIR Alarms................................................................................................................................. A-12A-14 ENET System Alarms............................................................................................................... A-12A-15 ENUM System Alarms............................................................................................................. A-13A-16 EROUTE Alarms....................................................................................................................... A-13A-17 Ethernet Error Threshold Alarms........................................................................................... A-14A-18 Fast Copy System Alarms........................................................................................................ A-14A-19 Frame Alarms............................................................................................................................ A-15A-20 Fuse Alarms............................................................................................................................... A-15A-21 GLS Alarms................................................................................................................................ A-15A-22 GPL Alarms............................................................................................................................... A-16A-23 Group Broadcast Alarms......................................................................................................... A-16A-24 GTT System Alarms.................................................................................................................. A-17A-25 HS Clock System Alarms......................................................................................................... A-17A-26 IMT Bus Alarms........................................................................................................................ A-18A-27 IMT System Alarms.................................................................................................................. A-18A-28 INP System Alarms................................................................................................................... A-19A-29 IP Connection Alarms.............................................................................................................. A-20A-30 IP Connection Alarms.............................................................................................................. A-20A-31 Linkset Alarms.......................................................................................................................... A-20A-32 LNP System Alarms................................................................................................................. A-21A-33 LSMS Connection Alarms........................................................................................................ A-22A-34 LSMS System Alarms............................................................................................................... A-22A-35 MCPM Alarms........................................................................................................................... A-22A-36 MEAS System Alarms.............................................................................................................. A-23A-37 MPS (ELAP/EPAP) Alarms..................................................................................................... A-23A-38 MPS Alarm Support................................................................................................................. A-24A-39 RTX System Alarms.................................................................................................................. A-24A-40 SCCP Service Alarms............................................................................................................... A-25A-41 SCCP System Alarms............................................................................................................... A-25A-42 SCTP Retransmit Alarms......................................................................................................... A-26
xxi
A-43 SEAS Major OAP Alarms........................................................................................................ A-27A-44 SEAS Minor OAP Alarms........................................................................................................ A-27A-45 SEAS System Alarms................................................................................................................ A-27A-46 SEAS X25 Alarms...................................................................................................................... A-28A-47 Security Log Alarms................................................................................................................. A-28A-48 Security System Alarms........................................................................................................... A-28A-49 SFLOG System Alarms............................................................................................................. A-29A-50 SLK Alarms................................................................................................................................ A-29A-51 STPLAN Alarms........................................................................................................................ A-33A-52 <subsystem> System Alarms.................................................................................................. A-34A-53 System Alarms........................................................................................................................... A-34A-54 System GPL Alarms.................................................................................................................. A-35A-55 T1 Port Alarms.......................................................................................................................... A-35A-56 Terminal Alarms........................................................................................................................ A-36A-57 V-Flex System Alarms.............................................................................................................. A-36A-58 X-LIST Alarms........................................................................................................................... A-36B-1 Application Subsystem Unsolicited Output Message Group............................................... B-1B-2 Card Unsolicited Output Message Group .............................................................................. B-7B-3 Clock Unsolicited Output Message Group .......................................................................... B-11B-4 Database Unsolicited Output Message Group..................................................................... B-13B-5 GTT Unsolicited Output Message Group ............................................................................ B-13B-6 GWS Unsolicited Output Message Group ........................................................................... B-17B-7 Link Maintenance Unsolicited Output Message Group..................................................... B-19B-8 Measurements Maintenance Unsolicited Output Message Group ................................... B-26B-9 Monitor Unsolicited Output Message Group ...................................................................... B-27B-10 MPS Unsolicited Output Message Group ............................................................................ B-28B-11 Program Update Unsolicited Output Message Group........................................................ B-29B-12 SEAS Maintenance Unsolicited Output Message Group ................................................... B-29B-13 Security Administration Unsolicited Output Message Group........................................... B-30B-14 SLAN Maintenance Unsolicited Output Message Group .................................................. B-30B-15 System Maintenance Unsolicited Output Message Groups............................................... B-31B-16 UIM Redirect Unsolicited Output Message Group............................................................. B-37C-1 Auto-Inhibit Hardware Verification Codes............................................................................. C-1
xxii
1About This User's Guide
This chapter describes the content and structure of the user's guide, indicates how toobtain help, details where to find related documentation, and provides other generalinformation.
OverviewUnsolicited Alarm and Information Messages Reference describes the EAGLE systemunsolicited alarm (UAM) and unsolicited information (UIM) messages sent to thesystem terminal whenever there is a system fault, whenever a previous fault conditionis corrected, or when a subsystem, equipment, and/or service is placed in or takenout-of-service. Each message has a trouble code and text associated with the troublecondition.
Note: EAGLE supporting ANSI networks make use of the LNP and SEASfeatures. EAGLE supporting ITU networks do not include these systems.
The manual is organized as follows:
• About This User's Guide provides general information about the organization ofthis manual.
• Message Type describes the different alarms and message types used in theEAGLE.
• UAM and UIM Troubleshooting Procedures provides procedures to use inresponse to unsolicited alarm messages (UAMs) and unsolicited informationmessages (UIMs) displayed by the EAGLE.
• In addition, the appendices of this manual provide useful reference material formaintenance, diagnostic, and troubleshooting activities:
– Appendix A: UAM Balancing Matrix
– Appendix B: Unsolicited Output Message Groups
– Appendix C: Auto-Inhibit Hardware Verification Codes
• Glossary that provides a list of acronyms and abbreviations
Scope and AudienceThis manual is intended for maintenance personnel who must maintain the EAGLE.The technician should be familiar with SS7 protocols. The manual provides preventiveand corrective procedures that will aid maintenance personnel in maintaining theEAGLE.
About This User's Guide 1-1
Preventive maintenance procedures are routines to be carried out on a scheduled basisto help prevent system failures. These routines are industry-standardrecommendations and may be adopted to fit any company maintenance plan.
The corrective maintenance procedures are those used in response to a system alarmor output message. These procedures are EAGLE-specific and aid in the detection,isolation, and repair of faults.
Documentation AdmonishmentsAdmonishments are icons and text throughout this manual that alert the reader toassure personal safety, to minimize possible service interruptions, and to warn of thepotential for equipment damage.
Table 1-1 Admonishments
Icon Description
Danger:
(This icon and text indicate the possibility ofpersonal injury.)
Warning:
(This icon and text indicate the possibility ofequipment damage.)
Caution:
(This icon and text indicate the possibility ofservice interruption.)
Topple:
(This icon and text indicate the possibility ofpersonal injury and equipment damage.)
Manual OrganizationThis document is organized into the following chapters:
• About This User's Guide contains overview information about this referencemanual, scope and audience and how to get technical assistance.
• Message Type provides an overview of the format of the alarm messages and theirpurpose.
• UAM and UIM Troubleshooting Procedures lists the alarm and informationmessages and their troubleshooting procedures.
• UAM Balancing Matrix includes tables with alarm types, severity and theirclearing alarms.
• Unsolicited Output Message Groups provides a list of alarms and informationmessages and their corresponding output groups.
Documentation Admonishments
1-2 EAGLE Unsolicited Alarm and Information Messages Reference
• Auto-Inhibit Hardware Verification Codes lists the auto-inhibit hardwareverification codes.
My Oracle Support (MOS)MOS (https://support.oracle.com) is your initial point of contact for all productsupport and training needs. A representative at Customer Access Support (CAS) canassist you with MOS registration.
Call the CAS main number at 1-800-223-1711 (toll-free in the US), or call the OracleSupport hotline for your local country from the list at http://www.oracle.com/us/support/contact/index.html. When calling, make the selections in the sequenceshown below on the Support telephone menu:
1. Select 2 for New Service Request
2. Select 3 for Hardware, Networking and Solaris Operating System Support
3. Select one of the following options:
• For Technical issues such as creating a new Service Request (SR), Select 1
• For Non-technical issues such as registration or assistance with MOS, Select 2
You will be connected to a live agent who can assist you with MOS registration andopening a support ticket.
MOS is available 24 hours a day, 7 days a week, 365 days a year.
Emergency ResponseIn the event of a critical service situation, emergency response is offered by theCustomer Access Support (CAS) main number at 1-800-223-1711 (toll-free in the US),or by calling the Oracle Support hotline for your local country from the list at http://www.oracle.com/us/support/contact/index.html. The emergency response providesimmediate coverage, automatic escalation, and other features to ensure that the criticalsituation is resolved as rapidly as possible.
A critical situation is defined as a problem with the installed equipment that severelyaffects service, traffic, or maintenance capabilities, and requires immediate correctiveaction. Critical situations affect service and/or system operation resulting in one orseveral of these situations:
• A total system failure that results in loss of all transaction processing capability
• Significant reduction in system capacity or traffic handling capability
• Loss of the system’s ability to perform automatic system reconfiguration
• Inability to restart a processor or the system
• Corruption of system databases that requires service affecting corrective actions
• Loss of access for maintenance or recovery operations
• Loss of the system ability to provide any required critical or major troublenotification
My Oracle Support (MOS)
About This User's Guide 1-3
Any other problem severely affecting service, capacity/traffic, billing, andmaintenance capabilities may be defined as critical by prior discussion and agreementwith Oracle.
Related PublicationsFor information about additional publications related to this document, refer to theOracle Help Center site. See Locate Product Documentation on the Oracle Help CenterSite for more information on related product publications.
Customer TrainingOracle University offers training for service providers and enterprises. Visit our website to view, and register for, Oracle Communications training:
http://education.oracle.com/communication
To obtain contact phone numbers for countries or regions, visit the Oracle UniversityEducation web site:
www.oracle.com/education/contacts
Locate Product Documentation on the Oracle Help Center SiteOracle Communications customer documentation is available on the web at the OracleHelp Center (OHC) site, http://docs.oracle.com. You do not have to register to accessthese documents. Viewing these files requires Adobe Acrobat Reader, which can bedownloaded at http://www.adobe.com.
1. Access the Oracle Help Center site at http://docs.oracle.com.
2. Click Industries.
3. Under the Oracle Communications subheading, click the OracleCommunications documentation link.
The Communications Documentation page appears. Most products covered bythese documentation sets will appear under the headings "Network SessionDelivery and Control Infrastructure" or "Platforms."
4. Click on your Product and then the Release Number.
A list of the entire documentation set for the selected product and release appears.
5. To download a file to your location, right-click the PDF link, select Save targetas (or similar command based on your browser), and save to a local folder.
Related Publications
1-4 EAGLE Unsolicited Alarm and Information Messages Reference
2Message Type
This chapter provides an overview of the format of the messages and their generalpurpose.
System Alarm LevelsThere are three levels of alarms in the EAGLE system. They are:
CriticalA critical alarm is an indication of a severe service affecting problem that can berelated to traffic, billing, and maintenance capabilities and requires immediatemaintenance attention, regardless of time of day.
MajorA major alarm is an indication of a problem that seriously affects system operation,maintenance and administration, etc. and requires immediate attention. The urgencyis less than in critical situations because of a lesser immediate or impending effect onsystem performance, customers, and operating company operations and revenue.
MinorA minor alarm is an indication of a problem that does not have a serious impact onservice, and does not require immediate maintenance attention.
Note: Some UAMs are considered informational if they satisfy the followingconditions in the SNMP V2 traps generated by EAGLE E5OAM:
1. The Alarm Level is stated as "No alarm condition" in this user's guide.
2. The alarm is not intended to clear any higher severity UAM as per thecorresponding UAM Balancing Matrix.
These UAMs are informational only and neither contribute to the total numberof alarms in the system nor change the alarm state of the device on EAGLE.
Output MessagesThe EAGLE generates output messages in response to command input or faultconditions in the EAGLE or in the network. The format for these messages is generallyuniform. Some messages include additional data.
Network messages provide the text description of the event, and on the lines belowthe text line, any additional information.
The following example shows the general format of an output message.
Message Type 2-1
Figure 2-1 Output Message Format
The fields in an output message (shown in the figure above) are described next:
• Host CLLI code - a maximum of one alpha character and ten alphanumericcharacters. The CLLI code uniquely identifies the system in terms of its physicallocation. The CLLI code must be unique among all elements in the system.
The CLLI code consists of the following:
– City = 4 characters
– State = 2 characters
– Building = 2 characters
– Equipment type = 3 characters
• Date - The date the message was generated, in the format year-month-day.
• Time - The time the message was generated with time zone, in the format hour:minutes: second time zone.
• System Release Number - contains a system identifier and the version IDnumber. The system identifier, can be EAGLE or EAGLE5 depending on theproduct key enabled on the system. The version ID number has the softwarerelease specific GPL set that is expected to be installed on the system as approvedloads. The format of the version ID number is in the form of maj.min.maint,defined as follows:
– maj - the major release ID
– min - the minor release ID
– maint - the maintenance release ID
• Alarm Level - a one or two character indicator of the alarm level, defined asfollows:
– *C = Critical Alarm
– ** = Major Alarm
– * = Minor Alarm
– blank = No Alarm
• Message Sequence Number - This number is an index for all output messages.The number increments sequentially for every message. The output messagesoriginating from the card in location 1113 has a range from 0001 through 4999. Therange for location 1115 is 5000 through 9999.
Output Messages
2-2 EAGLE Unsolicited Alarm and Information Messages Reference
• Message Reference Number - Messages that are associated with a specific actionare numbered for reference. These messages are defined in this chapter, along witha corrective action.
• Affected Device - The device that caused the message to be generated. Thisgenerally describes the card type.
Network messages with additional data display the additional lines below the textstring and message reference number (MRN). See individual messages for examples ofoutput.
All network messages are non-alarm and are used to notify the user of network events.There may or may not be a procedure associated with these messages.
Unsolicited Alarm Messages (UAM)The system sends unsolicited alarm messages to the system terminal whenever there isa system fault, whenever a previous fault condition is corrected, when a subsystem,equipment, and/or service is placed in or taken out of service. Each message has atrouble code and text associated with the trouble condition.
Unsolicited Information Messages (UIM)The system sends unsolicited information messages to the system terminal wheneverthere is a non-service affecting condition. This includes MSUs with invalidinformation, conversion failures, and/or a failed gateway screening function. Eachmessage has a numbered code and informational text associated with the condition.
Unsolicited Alarm Messages (UAM)
Message Type 2-3
Unsolicited Information Messages (UIM)
2-4 Unsolicited Alarm and Information Messages Reference
3UAM and UIM Troubleshooting Procedures
UAMsThe following are UAMs that may be displayed.
0001 - Card has reset
This could have been the result of a manual reset, or software reset. If the systemsoftware detects trouble with a card, the processors on the card (application orcommunication processors) are reset by software. The system software is responsiblefor this function.
Example
RLGHNCXA21W 94-02-07 12:01:43 EST EAGLE 35.0.0** 0014.0001 ** CARD 1113 OAM Card has reset
Alarm Level: Major
Recovery
1. The system recovers from this condition by reloading the card software.
If the card continually resets, replace the affected card. Refer to the Maintenancemanual for card removal/replacement procedures.
The recovery message sequence should be similar to:
** 0057.0001 ** CARD 1201 SS7ANSI Card has reset 0058.0096 CARD 1201 SS7ANSI Card has been reloaded 0059.0236 SLK 1201,A nc00027 REPT-LKF: not aligned 0060.0236 SLK 1201,B nc00027 REPT-LKF: not aligned 0061.0200 SLK 1201,A nc00027 RCVRY-LKF: link available 0062.0200 SLK 1201,B nc00027 RCVRY-LKF: link available
2. If the card resets without explanation or continues to reset, contact the My OracleSupport (MOS).
0008 - Active MASP has become isolated
This messages indicates the active MASP has a fault and the system switched to thestandby MASP. This could be caused by the MASP losing a connection to the IMT, afailure with the GPSM-II card, or a card reset.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0** 0014.0008 ** CARD 1113 OAM Active MASP has become isolated
UAM and UIM Troubleshooting Procedures 3-1
Alarm Level: Major
Recovery
1. Enter the following command to check the status of the IMT: rept-stat-imt
If the IMT is at fault, verify the IMT cables are connected to the shelf backplane(refer to the Installation Manual for cable locations).
2. If the state of the IMT appears good but the GPSM-II boots repeatedly, tryreseating the GPSM-II card.
If the problem persists, replace the GPSM-II card. Refer to the Maintenance manualfor card removal/replacement procedures.
3. If the trouble does not clear, obtain any obituary reports and contact the My OracleSupport (MOS).
0012 - Invalid HW for Integrated Measurements
The E5-OAM Integrated Measurements feature runs on the E5-MASP card. This UAMindicates that the E5-OAM Integrated Measurements feature is enabled and on, butone of the paired E5-MASP cards was removed from the active or standby MASPlocations and replaced with an incompatible GPSM-II (OAM) card.
Example
** 0014.0012 ** CARD 1113 OAM Invalid HW for Integrated Measurements
Alarm Level: Major
Recovery
1. Replace the GPSM-II (OAM) card in the active or standby position with a workingE5-MASP card so that the E5-OAM Integrated Measurements feature can runcorrectly.
Refer to the Maintenance manual for card removal/replacement procedures.
0013 - Card is isolated from the system
This indicates a card has become isolated and is unable to communicate to other cardsin the system. This could be caused by a defective card, a power failure occurred onthe card, a thermtrip when the shutdown temperature is exceeded, or the systemsoftware ordering a reset.
This also appears when the card has been manually reset by a command.
Example
RLGHNCXA21W 94-02-07 12:01:43 EST EAGLE 35.0.0** 0014.0013 ** CARD 1113 OAM Card is isolated from the system ASSY SN: 102199815a1234
Alarm Level: Major
Recovery
1. Enter the following command to check the status of the card:
rept-stat-card:loc=x:mode=full
UAMs
3-2 EAGLE Unsolicited Alarm and Information Messages Reference
where x is the card location stenciled on the shelf of the system.
Following is an example of the possible output using card 1106:
integrat40 00-05-24 10:37:22 EST EAGLE 35.0.0 CARD VERSION TYPE APPL PST SST AST 1106 021-101-000 TSM SCCP IS-NR Active ----- ALARM STATUS = No Alarms. IMT VERSION = 021-001-000 PROM VERSION = 021-001-000 IMT BUS A = Conn IMT BUS B = Conn CLOCK A = Active CLOCK B = Idle CLOCK I = Idle MBD BIP STATUS = valid DB STATUS = valid DBD MEMORY SIZE = 64M SCCP SERVICE = 1201, , 1214, 1215, 1217, 1102 SCCP % OCCUP = 0% SLK A PST = OOS-MT LS=ls11234567 CLLI= SLK B PST = OOS-MT LS=ls11345678 CLLI= SNM TVG RESULT = 24 hr: ------, 5 min: ------ SLAN TVG RESULT = 24 hr: ------, 5 min: ------ SCCP TVG RESULT = 24 hr: ------, 5 min: ------ Command Completed.
2. If only one card is isolated, wait to see if the card is recovering.
If not, reset the card.
3. If resetting the card does not clear the fault, reseat the card.
Note: For EPM-B based cards, the CPU shuts down automatically when theshutdown temperature is exceeded (thermtrip). After the temperature returnsto normal operating conditions, you must reseat the card to restore operation.
4. If reseating the card does not clear the fault, replace the card.
Refer to the Maintenance manual for card removal/replacement procedures.
5. If the alarm still does not clear, contact the My Oracle Support (MOS).
0028 - IMT Bus util rate exceeds major thresh
This message indicates that the combined IMT bus utilization rate has exceeded itsmajor threshold level.
Example
RLGHNCXA21W 09-02-07 12:01:43 EST EAGLE 41.1.0** 0590.0028 ** IMT SYSTEM IMT Bus util rate exceeds major thresh
Alarm Level: Major
Recovery
1. Note the time, duration, and frequency of the alarm(s).
UAMs
UAM and UIM Troubleshooting Procedures 3-3
2. Enter the rept-stat-mux command to note the rate at which the high-speed ringis operating.
3. Note any unusual conditions, such as one IMT bus inhibited, mate failed, SS7 linkfailures, etc.
4. If this is an isolated occurrence, no further action is required other than monitoringthe system for a re-occurrence.
5. If the problem persists and the high-speed ring is operating at "low bit rate," this isan indication that the system is operating at low capacity and an upgrade of thehigh-speed ring to operate at "high rate" is required. Contact the My OracleSupport (MOS) for information on how to purchase the HIPR2 High Rate Modefeature.
6. If the problem persists and the high-speed ring is operating at "high rate," contactthe My Oracle Support (MOS) for assistance.
0031 - HIPR2 detected a major Congested Second
This message indicates that the congestion on an IMT bus segment has reached a level2 congestion threshold. A congested second is a one-second time slice that contains 10or more congestion events that happen on that node.
When there are no major congested second events reported for a node for a period offive minutes, the major congested alarm is replaced with the minor congested secondalarm for that node.
Example
RLGHNCXA21W 09-02-07 12:01:43 EST EAGLE 41.1.0** 0590.0031 ** Card 1110 HIPR2 detected a major Congested Second
Alarm Level: Major
Recovery
1. Note the time, duration, and frequency of the alarm(s).
2. Enter the rept-stat-mux command to note the rate at which the high-speed ringis operating.
3. Note any unusual conditions, such as one IMT bus inhibited, mate failed, SS7 linkfailures, etc.
4. Note the segment(s) reporting the congestion.
5. If this is an isolated occurrence, no further action is required other than monitoringthe system for a re-occurrence.
6. If the problem persists and the high-speed ring is operating at "low rate," this is anindication that the system is operating at capacity and an upgrade of the high-speed ring to operate at "high rate" is required. Contact the My Oracle Support(MOS) for information on how to purchase the HIPR2 High Rate Mode feature.
7. If the problem persists and the high-speed ring is operating at "high rate," contactthe My Oracle Support (MOS) for assistance.
UAMs
3-4 EAGLE Unsolicited Alarm and Information Messages Reference
0041 - LSMS bulk load required
This message indicates that the entire system LNP database must be repopulated,either from the LSMS or a backup disk. This process must be started manually.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0* C0009.0041 *C LSMS SYSTEM LSMS bulk load required
Alarm Level: Critical
Recovery
Refer to the LNP Database Synchronization Manual for the LSMS Bulk Load procedure.
0047 - Card type not valid for application
This message indicates that a TSM card was replaced by an ASM card. The ASM cardis automatically inhibited because it is no longer supported.
Example
station1234 00-11-30 16:28:08 EST EAGLE 35.0.0** 0012.0047 ** CARD 1109 Card type not valid for applicationHW VERIFICATION CODE: xxx
HWVERIFICATIONCODE: xxx
Alarm Level: Major
Recovery
Replace the ASM card with the correct version of the TSM card.
Refer to the Maintenance manual for card removal/replacement procedures.
0051 - TSC sync is in simplex mode
Due to one or both GPSM-II cards being replaced with MCAPs after the feature bithas been set, the hardware configuration no longer supports the TSC Synchronizationfeature.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0051 ** CARD 1113 OAM TSC sync is in simplex mode
Alarm Level: Major
Recovery
Replace the MCAP(s) with GPSM-II card(s).
Refer to the Maintenance manual for card removal/replacement procedures.
0053 - Standby TDM failure
This message indicates that the communication between the GPSM-II and TDM hasfailed.
Example
UAMs
UAM and UIM Troubleshooting Procedures 3-5
station1234 94-03-30 16:28:08 EST EAGLE 35.0.0** 0012.0053 ** CARD 1113 OAM Standby TDM failure
Alarm Level: Major
Recovery
1. Enter the following command to verify card status:
rept-stat-card
2. Enter the following command to verify the database status:
rept-stat-db
3. Replace the failed TDM, that is in IS-ANR state with the backup TDM.
Note: If possible, replace the card during the maintenance window.
Refer to the Maintenance manual for card removal/replacement procedures.
0058 - Critical customer trouble detected
A critical customer trouble has been detected. There are connections on the controlshelf backplane for customer detected troubles (CDTs). Each connection is assigned anidentifier 1-16. CDT connections 2-4 are applicable to UAM 0058. CDT connections 6-8are applicable to UAM 0059. CDT connections 10-16 are applicable to UAM 0060. Thecustomer determines the connections on the backplane (these are dry contact closures).The system reports the alarm according to the connection location.
Example
RLGHNCXA21W 96:07:02 11:02:30 EST EAGLE 35.0.0*C 0100.0058 *C CDT 4 Critical customer trouble detected
Alarm Level: Critical
Recovery
Follow local procedures for clearing the indicated trouble.
0059 - Major customer trouble detected
A major customer trouble has been detected. There are connections on the control shelfbackplane for customer detected troubles (CDTs). Each connection is assigned anidentifier 1-16. CDT connections 2-4 are applicable to UAM 0058. CDT connections 6-8are applicable to UAM 0059. CDT connections 10-16 are applicable to UAM 0060. Thecustomer determines the connections on the backplane (these are dry contact closures).The system reports the alarm according to the connection location.
Example
RLGHNCXA21W 96:07:02 11:02:30 EST EAGLE 35.0.0** 0100.0059 ** CDT 8 Major customer trouble detected
Alarm Level: Major
Recovery
Follow local procedures for clearing the indicated trouble.
UAMs
3-6 EAGLE Unsolicited Alarm and Information Messages Reference
0063 - Critical holdover clock trbl detected
A critical trouble has been detected with the holdover clock. This could include aproblem with the reference input and stratum clock cards.
Example
RLGHNCXA21W 96:07:02 11:02:30 EST EAGLE 35.0.0 *C 0100.0063 *C CLOCK Critical holdover clock trbl detected
Alarm Level: Critical
Recovery
Check for any visual alarms.
Note any visual alarms and refer to the Maintenance manual for Holdover ClockTroubleshooting Procedures to perform the corrective action procedures.
0064 - Major holdover clock trouble detected
A major trouble has been detected with the holdover clock. This could include aproblem with the reference input and/or stratum clock cards.
Example
RLGHNCXA21W 96:07:02 11:02:30 EST EAGLE 35.0.0 ** 0100.0064 ** CLOCK Major holdover clock trouble detected
Alarm Level: Major
Recovery
Check for any visual alarms.
Note any visual alarms and refer to the Maintenance manual for Holdover ClockTroubleshooting Procedures to perform the corrective action procedures.
0077 - Card temperature is critical lvl:T2
An HC-MIM card, EPM based card (E5-E1T1, E5-ATM, E5-ENET, ET-IPSM, E5-TSM)EPM-B based card (E5-ATM-B, E5-ENET-B, E5-MCPM-B), or E5-SM8G-B card hasreached an operating temperature that is above the operational limit.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0*C 0100.0077 *C CARD 1102 LIMT1 Card temperature is critical lvl:T2
Alarm Level: Critical
Recovery
UAMs
UAM and UIM Troubleshooting Procedures 3-7
WARNING: There is a very limited time to solve this problem. For an HC-MIMcard, once the card exceeds its operation limit, all the links on the HC-MIMcard will be blocked (ACT-LPO), causing the links to go into local processoroutage. All traffic on the blocked links is re-directed elsewhere in the system(based on the current route provisioning). For information about EPM based,EPM-B based, and E5-SM8G-B cards, see "Changing the High-Capacity CardTemperature Alarm Thresholds" procedure in Database Administration Manual -SS7.
1. Verify that the fan assembly located in that shelf is working properly and that thefan filters are clean.
• Check to make sure there is both A and B power.
• Check the fans.
• Check the fan controller card and verify that all LEDs are green.
For proper operation (as a minimum B power must be present and good fansfor fan 2 and fan 3 must be installed before removing the controller).
• Check the fan filters.
• Replace any hardware in the fan assembly that is not functioning properly.Clean or replace fan filters as needed.
• Replace the fan tray only after checking power, fans, fan filters, and controlcard.
Contact the My Oracle Support (MOS) for assistance.
The hierarchy of maintenance activity is based on Table 3-1. See the Maintenancemanual for card removal/replacement procedures.
Table 3-1 Maintenance Activity Hierarchy
Condition Cntrl LED FAN 1 LED FAN 2 LED FAN 3 LEDAlarmStatus Actions
NormalOperation
Green Green Green Green NoAlarm**
None
A powerfeed fail
Blink RED Alarm* Check thefuse, thepowersource,and cables
Interconnect card ORcircuit fail
Blink RED Alarm* Check thefuse, thepowersource,and cables
B powerfeed fail
Blink RED Alarm* Check thefuse, thepowersource,and cables
UAMs
3-8 EAGLE Unsolicited Alarm and Information Messages Reference
Table 3-1 (Cont.) Maintenance Activity Hierarchy
Condition Cntrl LED FAN 1 LED FAN 2 LED FAN 3 LEDAlarmStatus Actions
Fan 1 fail Green RED Alarm* Make surethat thereis A power
Make surethat thereis B powerand thatFan 2 andFan 3 areoperatingproperly.
Replacethe fan.
Fan 2 fail Green RED Alarm* Make surethat thereis both Aand Bpower
Make surethat Fan 1and Fan 3areoperatingproperly
Replacethe fan
Fan 3 fail Green RED Alarm* Make surethat thereis B power
Make surethat thereis A powerand thatFan 1 andFan 2 areoperatingproperly
Replacethe fan
Fan 1Removed
Green Blink Alarm* Make surethat thefan isseatedproperly
Replacethe fan
UAMs
UAM and UIM Troubleshooting Procedures 3-9
Table 3-1 (Cont.) Maintenance Activity Hierarchy
Condition Cntrl LED FAN 1 LED FAN 2 LED FAN 3 LEDAlarmStatus Actions
Fan 2Removed
Green Blink Alarm* Make surethat thefan isseatedproperly
Replacethe fan
Fan 3Removed
Green Blink Alarm* Make surethat thefan isseatedproperly
Replacethe fan
Controllercardpartial fail
RED Alarm* Make surethere isboth Aand Bpower.
Make surethe fansareworkingproperly
RemoveFan 1
Replacethe FanTrayController
Controllercard fail
OFF OFF OFF OFF Alarm* Make surethere isboth Aand Bpower
Make surethe fansareworkingproperly
RemoveFan 1
Replacethe FanTrayController
Interconnect Failure
Replaceshelf
UAMs
3-10 EAGLE Unsolicited Alarm and Information Messages Reference
Note:
• *If there is no alarm for this condition, it is likely that the relay on theInterconnect card has failed (opened).
• **If there is an alarm when all 4 LEDs are green, it is likely that the relayon the Interconnect card has failed (closed).
• Try replacing the controller before replacing the fan tray.
2. If the fan unit is working properly, employ additional cooling methods to the cardreporting a high-operating temperature.
3. This Critical Temperature Alarm will remain in the system until the operationaltemperature of the HC-MIM card (HC Blade), EPM based card (E5-E1T1, E5-ATM,E5-ENET, ET-IPSM, E5-TSM) EPM-B based card (E5-ATM-B, E5-ENET-B, E5-MCPM-B), or E5-SM8G-B card goes below the critical temperature threshold.
4. If this procedure did not clear the fault, contact the My Oracle Support (MOS).
0078 - Card temperature exceeds nominal lvl:T1
An HC-MIM card, EPM based card (E5-E1T1, E5-ATM, E5-ENET, E5-IPSM, E5-TSM),EPM-B based card (E5-ATM-B, E5-ENET-B, E5-MCPM-B), or E5-SM8G-B card hasreached an operating temperature that is above the pre-defined limit.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0078 ** CARD 1102 LIMT1 Card temperature exceeds nominal lvl:T1
Alarm Level: Major
Recovery
warning: There is a very limited time to solve this problem. Once the cardexceeds its operation limit, all the links on the HC-MIM card will be blocked(ACT-LPO), causing the links to go into local processor outage. All traffic onthe blocked links is re-directed elsewhere in the system (based on the currentroute provisioning). For information about EPM based, EPM-B based, and E5-SM8G-B cards, see "Changing the High-Capacity Card Temperature AlarmThresholds" procedure in Database Administration Manual - SS7.
1. Enter the following command to verify the temperature threshold defaults arewithin the correct range for the card:
rtrv-th-alm
For HC-MIM cards, the maximum operating temperature is 82 degrees Celsius. ForEPM based cards (E5-E1T1, E5-ATM, E5-ENET, ET-IPSM, E5-TSM), the maximumoperating temperature is 95 degrees Celsius. For EPM-B based cards (E5-ATM-B,E5-ENET-B, E5-MCPM-B) and E5-SM8G-B cards, maximum operating temperatureis 90 degrees Celsius. Temperature Level 1 threshold (Thermal Alarm Level 1) andTemperature Level 2 threshold (Thermal Alarm Level 2) are user configurable.Temperature Level 1 threshold can be configured between 73%–92% (default is92%) of maximum operating temperature of the card and Temperature Level 2
UAMs
UAM and UIM Troubleshooting Procedures 3-11
threshold can be configured between 74%–100% (default is 100%) of maximumoperating temperature of the card.
If the thresholds are set incorrectly (or to temporarily suppress the alarm), go to 2.If the thresholds are correct, go to 3.
2. The threshold can be reset by entering the following command:
chg-th-alm:thermallv1c=xxxx
where:xxxx is temperature.
3. Skip this step for EPM-based cards. Verify that the fan assembly located in thatshelf is working properly and that the fan filters are clean.
• Check to make sure there is both A and B power.
• Check the fans.
• Check the fan controller card and verify that all LEDs are green.
For proper operation (as a minimum B power must be present and good fansfor fan 2 and fan 3 must be installed before removing the controller).
• Check the fan filters.
• Replace any hardware in the fan assembly that is not functioning properly.Clean or replace fan filters as needed.
• Replace the fan tray only after checking power, fans, fan filters, and controlcard.
Contact the My Oracle Support (MOS) for assistance.
The hierarchy of maintenance activity is based on Table 3-2. See the Maintenancemanual for card removal/replacement procedures.
Table 3-2 Maintenance Activity Hierarchy
Condition Cntrl LED FAN 1 LED FAN 2 LED FAN 3 LEDAlarmStatus Actions
NormalOperation
Green Green Green Green NoAlarm**
None
A powerfeed fail
Blink RED Alarm* Check thefuse, thepowersource,andcables.
Interconnect card ORcircuit fail
Blink RED Alarm* Check thefuse, thepowersource,andcables.
UAMs
3-12 EAGLE Unsolicited Alarm and Information Messages Reference
Table 3-2 (Cont.) Maintenance Activity Hierarchy
Condition Cntrl LED FAN 1 LED FAN 2 LED FAN 3 LEDAlarmStatus Actions
B powerfeed fail
Blink RED Alarm* Check thefuse, thepowersource,andcables.
Fan 1 fail Green RED Alarm* Make surethat thereis Apower.
Make surethat thereis B powerand thatFan 2 andFan 3 areoperatingproperly.
Replacethe fan.
Fan 2 fail Green RED Alarm* Make surethat thereis both Aand Bpower.
Make surethat Fan 1and Fan 3areoperatingproperly.
Replacethe fan.
Fan 3 fail Green RED Alarm* Make surethat thereis B power.
Make surethat thereis A powerand thatFan 1 andFan 2 areoperatingproperly.
Replacethe fan.
UAMs
UAM and UIM Troubleshooting Procedures 3-13
Table 3-2 (Cont.) Maintenance Activity Hierarchy
Condition Cntrl LED FAN 1 LED FAN 2 LED FAN 3 LEDAlarmStatus Actions
Fan 1Removed
Green Blink Alarm* Make surethat thefan isseatedproperly.
Replacethe fan.
Fan 2Removed
Green Blink Alarm* Make surethat thefan isseatedproperly.
Replacethe fan.
Fan 3Removed
Green Blink Alarm* Make surethat thefan isseatedproperly.
Replacethe fan.
Controllercardpartial fail
RED Alarm* Make surethere isboth Aand Bpower.
Make surethe fansareworkingproperly.
RemoveFan 1.
Replacethe FanTrayController.
UAMs
3-14 EAGLE Unsolicited Alarm and Information Messages Reference
Table 3-2 (Cont.) Maintenance Activity Hierarchy
Condition Cntrl LED FAN 1 LED FAN 2 LED FAN 3 LEDAlarmStatus Actions
Controllercard fail.
OFF OFF OFF OFF Alarm* Make surethere isboth Aand Bpower.
Make surethe fansareworkingproperly.
RemoveFan 1.
Replacethe FanTrayController.
Interconnect Failure
Replaceshelf.
Note:
• * If there is no alarm for this condition, it is likely that the relay on theInterconnect card has failed (opened).
• ** If there is an alarm when all 4 LEDs are green, it is likely that the relayon the Interconnect card has failed (closed).
• Try replacing the controller before replacing the fan tray.
4. If the fan unit is working properly, employ additional cooling methods to the cardreporting a high-operating temperature.
5. If the running temperature of the HC-MIM card, EPM based card (E5-E1T1, E5-ATM, E5-ENET, E5-IPSM, E5-TSM), EPM-B based card (E5-ATM-B, E5-ENET-B, E5-MCPM-B), or E5-SM8G-B card exceeds its operational limit, UAM 0077 isgenerated. HC-MIM links go into Local Processor Outage (LPO). For informationabout EPM based, EPM-B based, and E5-SM8G-B cards, see "Changing the High-Capacity Card Temperature Alarm Thresholds" procedure in DatabaseAdministration Manual - SS7.
6. This Temperature Alarm will remain in the system until the operationaltemperature of the HC-MIM card (HC Blade), EPM based card (E5-E1T1, E5-ATM,E5-ENET, E5-IPSM, E5-TSM), EPM-B based card (E5-ATM-B, E5-ENET-B, E5-MCPM-B), or E5-SM8G-B card returns to normal levels.
7. If performing the steps in this procedure did not clear the fault, contact the MyOracle Support (MOS) for assistance.
8. If the threshold was changed in 2 to temporarily suppress the alarm, enter thefollowing command to reset the threshold to the original setting:
UAMs
UAM and UIM Troubleshooting Procedures 3-15
chg-th-alm:thermallv1c=xxxx
where:xxxx is temperature.
0080 - Shelf FAN bit is OFF
The Eagle Shelf FAN bit is not turned on.
Example
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890 xxxx.0080 *C CARD 1103 LIMT1 Shelf FAN bit is OFF
Alarm Level: Major
Recovery
To turn the Shelf FAN bit on, use the following command:
chg-shlf
0081 - Shelf FAN bit is ON
The Eagle Shelf FAN bit is turned on. This UAM is an informational message thatconfirms that the feature is restored to operational status
Example
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890 xxxx.0081 *C CARD 1103 LIMT1 Shelf FAN bit is ON
Alarm Level: Normal
Recovery
This message indicates that the feature previously was OFF and now has been turnedON.
No further action is necessary.
0082 - Alarm in Fuse panel
A blown fuse has been detected in the fuse panel located on top of the designatedframe.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0082 ** FUSE PANEL 11xx Alarm in Fuse panel
Alarm Level: Major
Recovery
1. Locate the fuse and alarm panel (FAP) indicated in the alarm message.
2. Look at the set of fuses and find the fuse with the “flag” standing out.
UAMs
3-16 EAGLE Unsolicited Alarm and Information Messages Reference
This indicates the fuse is blown. Replace the fuse with a GMT 3 amp or 1 amp(depending on the type being replaced). See the Installation Manual for the correctfuse type.
Caution: Arbitrarily removing a good fuse will cause all cards serviced by theremoved fuse to fail. Verify the fuse output before pulling a fuse that appearsto be good.
3. If no fuses appear to be blown, use a VOM and measure the voltage outputs on therear of the panel (refer to the Installation Manual for voltage test points).
4. If the fuse blows again, visually inspect the shelf backplanes for shorts or metallicdebris.
5. If nothing can be found visually, put all cards serviced by the affected fuse out ofservice with the following command:
rmv-card:loc=x
where x is the card location stenciled on the shelf of the system.
6. Unplug the cards serviced by the affected fuse.
7. Replace the fuse.
8. Plug in each card one at a time.
As each card is plugged in, verify the fuse does not blow. When the fuse does blow,replace the card just plugged in.
9. Replace the fuse again.
10. Continue plugging in the remaining cards, verifying the fuse does not blow witheach card.
Each time the fuse does blow, replace the card and continue. There may be morethan one card at fault. If you encounter a card which blows the fuse, do not stop theprocedure. Continue until all cards have been plugged in. Refer to the Maintenancemanual for card removal/replacement procedures.
11. If all the cards are plugged in and the fault has cleared, place the affected cardsback into service by entering the following command:
rst-card:loc=x
where x is the card location stenciled on the shelf of the system.
12. If this does not clear the fault, contact the My Oracle Support (MOS).
0084 - IP Connection Unavailable
The TCP/IP and SIGTRAN protocols both have an IP layer. This UAM indicates thateither a TCP/IP socket or an SCTP/IP (SIGTRAN) association is unavailable.
Example
RLGHNCXA03W 09-11-06 16:28:08 EST EAGLE5 41.1.0** 1234.0084 ** IP7CONN LONGSOCKETNAME1 IP Connection Unavailable
UAMs
UAM and UIM Troubleshooting Procedures 3-17
Alarm Level: Major
Recovery
There are six recovery procedures for this UAM. The first two procedures are forTCP/IP socket problems; the third procedure is for SCTP/IP (SIGTRAN) problems.Read the UAM to see which entity has been affected, then refer to the followingscenarios to help determine which procedure to use:
• Use the Recovery procedure for EDCMs running STC GPLwhen an IP applicationsocket is out of service due to an IP link down (Ethernet problem) or due to theSTC card.
• Use the Recovery procedure for DSM with EPAP or ELAP when an IP link isdown. The link may be a DSM (Database Service Module) to MPS link.
• Use the Recovery procedure for IPLMx, IPGWx, and IPSG when failure at the IPlevel is affecting associations used for SS7-over-IP (SIGTRAN) links.
• Use the Recovery procedure for MCP or MCPHCwhen UAM 0084 says that theproblem is MCP or MCPHC.
• Use the Recovery procedure for OAMHCwhen UAM 0084 says that the problemis OAMHC.
• Use the Recovery procedure for SNMP when UAM 0084 says that the problem isSNMP.
Recovery procedure for EDCMs running STC GPL
In this scenario, this message typically occurs if STC port does not get a DHCP leasefrom IMF/ESP side. However, it could also be due to bad hardware or bad port onSTC card. This error may be due to mis-configured IMF/ESP switches that may notsend DHCP lease to STC card.
1. Use the rept-stat-card command to view STC status.
The following is an example of a possible output:
tekelecstp 07-05-06 15:40:32 EST EAGLE 37.0.0
CARD VERSION TYPE GPL PST SST AST 1103 128-002-000 STC ERTHC IS-NR Active ----- ALARM STATUS = No Alarms. IMTPCI GPL version = 128-002-000 BLVXW6 GPL version = 128-002-000 BLDIAG6 GPL version = 128-002-000 BLBEPM GPL version = 128-002-000 BLCPLD GPL version = 128-002-000 IMT BUS A = Conn IMT BUS B = Conn CLOCK A = Active CLOCK B = Idle CLOCK I = Idle MBD BIP STATUS = Valid MOTHER BOARD ID = EPM A DBD STATUS = Valid DBD TYPE = 1G ENET DBD MEMORY SIZE = 512M HW VERIFICATION CODE = ---- CURRENT TEMPERATURE = 51C (124F)
UAMs
3-18 EAGLE Unsolicited Alarm and Information Messages Reference
PEAK TEMPERATURE: = 51C (124F) [02-09-20 10:48] EROUTE % OCCUP = 0% NTP broadcast = VALID STC IP PORT A: IS-NR Active ----- ALARM STATUS = No Alarms. STC IP PORT B: OOS-MT Unavail ----- ALARM STATUS = ** 0084 IP Connection Unavailable ERROR STATUS = DHCP Lease. Physical Link.
Command Completed.;
If the STC is in service and one of the ports is showing UAM0084, then this port isnot getting the address from the DHCP server.
2. If rept-stat-card shows that both ports are in UAM0084 state then use thenetstat –I command to determine if the Ethernet interfaces are up.
a. If they are up, then IMF/ESP support should be involved to find out why thisport is not getting the DHCP.
b. If the concerned ports are not up, then it could be a hardware issue, replace thecard. See the Maintenance Manual,Appendix A, Card Removal/ReplacementProcedures.
3. If the alarm is not cleared, contact the My Oracle Support (MOS).
Recovery procedure for DSM with EPAP or ELAP
1. Use the rep-stat-mps command to obtain MPS status.
The following is an example of a possible output:
> rept-stat-mps
Command Accepted - Processing peliscaa00w 04-08-13 11:11:04 EDT EAGLE 29.0.2-46.33.1 rept-stat-mps Command entered at terminal #2.;
peliscaa00w 04-08-13 11:11:04 EDT EAGLE 29.0.2-46.33.1 VERSION PST SST AST ELAP A 002-002-000 IS-NR Active ----- CRITICAL PLATFORM ALARM DATA = No Alarms MAJOR PLATFORM ALARM DATA = No Alarms MINOR PLATFORM ALARM DATA = No Alarms CRITICAL APPLICATION ALARM DATA = No Alarms MAJOR APPLICATION ALARM DATA = No Alarms MINOR APPLICATION ALARM DATA = No Alarms ALARM STATUS = No Alarms. VERSION PST SST AST ELAP B 002-002-000 IS-NR Standby ----- CRITICAL PLATFORM ALARM DATA = No Alarms MAJOR PLATFORM ALARM DATA = No Alarms MINOR PLATFORM ALARM DATA = No Alarms CRITICAL APPLICATION ALARM DATA = No Alarms MAJOR APPLICATION ALARM DATA = No Alarms MINOR APPLICATION ALARM DATA = No Alarms ALARM STATUS = No Alarms. CARD PST SST LNP STAT
UAMs
UAM and UIM Troubleshooting Procedures 3-19
1101 P IS-NR Active ACT 1103 IS-NR Active ACT CARD 1101 ALARM STATUS = No Alarms. DSM PORT A: ALARM STATUS = ** 0084 IP Connection Unavailable DSM PORT B: ALARM STATUS = ** 0084 IP Connection Unavailable CARD 1103 ALARM STATUS = No Alarms. DSM PORT A: ALARM STATUS = ** 0084 IP Connection Unavailable DSM PORT B: ALARM STATUS = ** 0084 IP Connection Unavailable Command Completed.;
2. Use the rept-stat-db:display=all:db=mps to determine the “LEVEL” onthe DSM cards are not incrementing.
The following is an example of a possible output:
> rept-stat-db:display=all:db=mps Command Accepted - Processing peliscaa00w 04-08-13 11:14:32 EDT EAGLE 29.0.2-46.33.1 rept-stat-db:display=all:db=mps Command entered at terminal #2.;
peliscaa00w 04-08-13 11:14:32 EDT EAGLE 29.0.2-46.33.1
ELAP A ( ACTV ) C BIRTHDATE LEVEL EXCEPTION - ----------------- ---------- -------------- RTDB Y 04-08-13 02:32:02 1264 - RTDB-EAGLE 04-08-13 02:29:22 1264 -
ELAP B ( STDBY ) C BIRTHDATE LEVEL EXCEPTION - ----------------- ---------- -------------- RTDB Y 04-08-13 02:32:02 1264 - RTDB-EAGLE 04-08-13 02:29:22 1264 - EAGLE RTDB REPORT CARD/APPL LOC C BIRTHDATE LEVEL EXCEPTION --------- ---- - ----------------- ---------- -------------- VSCCP 1101 Y 04-08-13 02:29:22 1108 - VSCCP 1103 Y 04-08-13 02:29:22 1108 -;
3. Execute rept-stat-trbl:display=timestamp to see if all of the UAM 0084occurred at nearly the same time.
If all of the DSMs are reporting IP connection unavailable and all of the alarmscame in at one time, check whether the associated EPAP or ELAP has a problem. Ifso, go to 7.
4. Perform the following to verify IP network connectivity.
a. Use the following command to ping the local host:
pass:loc=XXXX:cmd=”ping 127.0.0.1”
This is the loopback address and testing it will indicate if networking support isfunctioning.
b. Ping the MPS using:
UAMs
3-20 EAGLE Unsolicited Alarm and Information Messages Reference
pass:loc=XXXX:cmd=”ping 192.168.120.100” for 100 Megabit Network
pass:loc=XXXX:cmd=”ping 192.168.120.200” for 100 Megabit Network
pass:loc=XXXX:cmd=”ping 192.168.121.100” for 10 Megabit Network
pass:loc=XXXX:cmd=”ping 192.168.121.200” for 10 Megabit Network
Example of a possible output:
192.168.120.100 for EPAP A, via DSM Port A / 100 Megabit Network192.168.120.200 for EPAP B, via DSM Port A / 100 Megabit Network,192.168.121.100 for EPAP A, via DSM Port B / 10 Megabit Network,192.168.121.200 for EPAP B, via DSM Port B / 10 Megabit Network
c. If the ping command is not working, verify the IP network cabling.
Note: The network between the MPS and the DSMs is a private network.
d. Replace the DSM card if you can’t ping the local host and the IP network hasbeen verified.
See the Maintenance Manual, Appendix A, Card Removal/Replacement Procedures.
Note: This step applies to a single DSM having IP connection unavailable.
5. If all of the DSMs are reporting IP connection unavailable, reboot the "primary"DSM card. If no primary card is available go to 3. If only one card is reporting IPconnection unavailable, use the init command to take down the card and reload it.See the Commands Manual for the INIT-CARD command.
6. Power cycle the hubs between the MPS and the EAGLE STP.
7. Task to be completed by either the customer or an Engineer from the LSMS/MPS group:Run a syscheck on the EPAP or ELAP.
8. Task to be completed by either the customer or an Engineer from the LSMS/MPS group:Switch activity on the EPAP or ELAP.
If this action does not clear the alarm, continue to 9.
9. Task to be completed by either the customer or an Engineer from the LSMS/MPS group:Stop and restart the software on the EPAP or ELAP.
In case of failure of the Active EPAP, the Standby EPAP takes over the role of ActiveEPAP and continues to provision the database. If the main DSM network fails, theActive EPAP switches to the backup DSM network to continue provisioning theService Module cards. The switchover to the backup DSM network is possible onlywhen all connectivity is lost on the main DSM network. In case of HUB failure,impact on the provisioning may be partial, so switchover to the backupprovisioning network might not be automatically triggered. At any given time,there is only one Active EPAP using one DSM network per EPAP system.
If this action does not clear the alarm, continue to 10.
10. If these steps do not clear the fault, contact the My Oracle Support (MOS).
UAMs
UAM and UIM Troubleshooting Procedures 3-21
When the IP connection recovers you will see an IP Connection Availablemessage.
UAM: 1481.0085 DSM A 1101 IP Connection Available1482.0085 DSM B 1101 IP Connection Available
Recovery procedure for IPLMx, IPGWx, and IPSG
1. Enter the rept-stat-card:loc=<location>:mode=full command.
Example of command and possible output:
rept-stat-card:loc=1301:mode=full Command entered at terminal #3.;
eagle10212 01-05-27 07:44:48 EST ??.?.?-63.18.0 CARD VERSION TYPE GPL PST SST AST 1301 067-018-000 DCM IPLIM IS-NR Active ----- ALARM STATUS = No Alarms. BPDCM GPL version = 133-009-000 IMT BUS A = Conn IMT BUS B = Conn CLOCK A = Active CLOCK B = Idle CLOCK I = Idle MBD BIP STATUS = Valid MOTHER BOARD ID = SS EDCM DBD STATUS = Valid DBD TYPE = None DBD MEMORY SIZE = 0M HW VERIFICATION CODE = ---- SIGNALING LINK STATUS SLK PST LS CLLI A OOS-MT e3e4 ----------- B OOS-MT e3e4 ----------- IPLNK STATUS IPLNK IPADDR STATUS PST A 10.254.110.9 DOWN OOS-MT B 192.168.51.14 UP IS-NR ASSOCIATION STATUS ANAME PST SST ipl1301a OOS-MT CONNECTING ipl1301b OOS-MT CONNECTING TVG STATUS SNM TVG RESULT = 24 hr: G-----, 5 min: ------ SLAN TVG RESULT = 24 hr: ------, 5 min: ------ SCCP TVG RESULT = 24 hr: ------, 5 min: ------ INM TVG RESULT = 24 hr: G-----, 5 min: ------
Command Completed.
2. If the hardware interface is down, there is nothing more you can do. Contact the farend, which is where the problem must be resolved. If the hardware interface is up,execute the following commands to get more troubleshooting information:
a. Errors (collisions, etc.) on the network interface?
netstat -d 0/1t
UAMs
3-22 EAGLE Unsolicited Alarm and Information Messages Reference
b. Far end reachable?
ping
traceroute
c. Near end and far end use same SCTP CRC?
netstat –p sctp
rtrv-sg-opts
3. Failure at the lower IP level causes problems for the Application Servers (AS)higher in the SCTP/IP stack, so you can use the rep-stat-as command to getmore information about the association status.
4. Contact the My Oracle Support (MOS).
Recovery procedure for MCP or MCPHC
In this scenario, the message typically occurs if the Measurements application loses theconnection with the measurements FTP server. The error could be caused by a networkconnectivity problem or a misconfiguration of the FTP server parameters.
1. Enter the rtrv-ftp-serv command. If a measurement server is listed, verify theparameters.
Example of command and possible output:
rtrv-ftp-serv Command entered at terminal #6.;
e1061001 11-09-30 02:31:38 MST EAGLE5 44.0.0-64.10.0
APP IPADDR LOGIN PRIO PATH -------- --------------- --------------- ---- ---- meas 10.241.14.62 eagleuser 1 /meas/reports
FTP SERV table is (1 of 10) 10% full;
2. If the output does not show an entry for the meas application, configure ameasurements FTP server in accordance with the “Adding an FTP Server”procedure in Database Administration Manual - System Management to clear thealarm.
3. Verify connectivity with the FTP server with the ping command. Enter thepass:loc=<mcp>:cmd=”ping <server ipaddr>” command.
Example of command and possible output:
> pass:loc=1105:cmd="ping 10.241.14.62"
Command Accepted - Processing
e1061001 11-09-30 02:53:17 MST EAGLE5 44.0.0-64.10.0 pass:loc=1105:cmd="ping 10.241.14.62" Command entered at terminal #6.;
e1061001 11-09-30 02:53:17 MST EAGLE5 44.0.0-64.10.0
UAMs
UAM and UIM Troubleshooting Procedures 3-23
PASS: Command sent to card;
e1061001 11-09-30 02:53:17 MST EAGLE5 44.0.0-64.10.0
PING command in progress
;
e1061001 11-09-30 02:53:18 MST EAGLE5 44.0.0-64.10.0
;
e1061001 11-09-30 02:53:20 MST EAGLE5 44.0.0-64.10.0 PING 10.241.14.62: 56 data bytes 64 bytes from 10.241.14.62: icmp_seq=0. time=5. ms 64 bytes from 10.241.14.62: icmp_seq=1. time=5. ms 64 bytes from 10.241.14.62: icmp_seq=2. time=5. ms ----10.241.14.62 PING Statistics---- 3 packets transmitted, 3 packets received, 0% packet loss round-trip (ms) min/avg/max = 5/5/5
PING command complete
;
If the ping test fails, verify the physical network connectivity between the Eagleand the FTP server.
4. If the ping command is successful, attempt to transfer a file to the FTP server. Enterthe pass:loc=<mcp>:cmd=”ftptest –a meas” command.
Example of command and possible output:
> pass:loc=1105:cmd="ftptest -a meas"Command Accepted - Processing e1061001 11-09-30 02:56:02 MST EAGLE5 44.0.0-64.10.0 pass:loc=1105:cmd="ftptest -a meas" Command entered at terminal #6.; e1061001 11-09-30 02:56:02 MST EAGLE5 44.0.0-64.10.0 PASS: Command sent to card; e1061001 11-09-30 02:56:02 MST EAGLE5 44.0.0-64.10.0 FTPTEST: Command In Progress; e1061001 11-09-30 02:56:02 MST EAGLE5 44.0.0-64.10.0 FTP Interface Test Test Results: PASS Server IP: 10.241.14.62 FTP Error: 0 Segment: 190004fa Diag Msg:
FTPTEST: Command Complete
;
5. If the alarm is not cleared, try the FTP from another system and verify the login anddirectory. If this is unsuccessful, contact the My Oracle Support (MOS).
UAMs
3-24 EAGLE Unsolicited Alarm and Information Messages Reference
Recovery procedure for OAMHC
In this scenario, the message typically occurs if the Measurements application or theSNMP application loses the connection with the measurements host server. The errorcould be caused by a network connectivity problem or a misconfiguration of the serverparameters.
1. Enter the rtrv-ctrl-feat command.
Example of command and possible output:
rtrv-ctrl-featCommand entered at terminal #4.;
tekelecstp1 12-09-22 01:53:11 EST EAGLE5 45.0.0-64.42.0The following features have been permanently enabled:
Feature Name Partnum Status QuantityRoutesets 893006405 on 10000Telnet 893005701 on ----EAGLE5 Product 893007101 on ----HC-MIM SLK Capacity 893012707 on 64EAGLE OA&M IP Security 893400001 on ----Integrated Measurements 893037301 on ----EAGLE SNMP 893040401 on ----
2. If the Integrated Measurements feature is enabled, perform Recovery Procedure forIntegrated Measurements. If the Eagle SNMP feature is enabled, perform RecoveryProcedure for SNMP.
Recovery procedure for Integrated Measurements
In this scenario, the message typically occurs if the Integrated Measurementsapplication loses the connection with the measurements FTP server. The error could becaused by a network connectivity problem or a misconfiguration of the FTP serverparameters.
1. Enter the rtrv-ftp-serv command. If a measurement server is listed, verify theparameters.
Example of command and possible output:
rtrv-ftp-servCommand entered at terminal #6.;e1061001 12-09-30 02:31:38 EST EAGLE5 45.0.0-64.44.0APP IPADDR LOGIN PRIO PATH-------- --------------- --------------- ---- ----meas 10.241.14.62 eagleuser 1 /meas/reportsFTP SERV table is (1 of 10) 10% full;
2. If the output does not show an entry for the meas application, configure ameasurements FTP server in accordance with the “Adding an FTP Server”procedure in Database Administration Manual - System Management to clear thealarm.
3. Verify connectivity with the FTP server with the ping command. Enter thepass:loc=[1113 | 1115]:cmd="ping <server ipaddr>" command.
UAMs
UAM and UIM Troubleshooting Procedures 3-25
Example of command and possible output:
> pass:loc=1105:cmd="ping 10.241.14.62"
Command Accepted - Processing
e1061001 11-09-30 02:53:17 MST EAGLE5 44.0.0-64.10.0 pass:loc=1105:cmd="ping 10.241.14.62" Command entered at terminal #6.;
e1061001 11-09-30 02:53:17 MST EAGLE5 44.0.0-64.10.0 PASS: Command sent to card;
e1061001 11-09-30 02:53:17 MST EAGLE5 44.0.0-64.10.0
PING command in progress
;
e1061001 11-09-30 02:53:18 MST EAGLE5 44.0.0-64.10.0
;
e1061001 11-09-30 02:53:20 MST EAGLE5 44.0.0-64.10.0 PING 10.241.14.62: 56 data bytes 64 bytes from 10.241.14.62: icmp_seq=0. time=5. ms 64 bytes from 10.241.14.62: icmp_seq=1. time=5. ms 64 bytes from 10.241.14.62: icmp_seq=2. time=5. ms ----10.241.14.62 PING Statistics---- 3 packets transmitted, 3 packets received, 0% packet loss round-trip (ms) min/avg/max = 5/5/5
PING command complete
;
If the ping test fails, verify the physical network connectivity between the Eagleand the FTP server.
4. If the ping command is successful, attempt to transfer a file to the FTP server. Enterthe pass:loc=[1113 | 1115]:cmd="ftptest -a meas"command.
Example of command and possible output:
> pass:loc=1113:cmd="ftptest -a meas"
Command Accepted – Processing
e1061001 12-09-30 02:56:02 EST EAGLE5 45.0.0-64.44.0pass:loc=1113:cmd="ftptest -a meas"Command entered at terminal #6.;
e1061001 12-09-30 02:56:02 EST EAGLE5 45.0.0-64.44.0PASS: Command sent to card;
e1061001 12-09-30 02:56:02 EST EAGLE5 45.0.0-64.44.0FTPTEST: Command In Progress;
UAMs
3-26 EAGLE Unsolicited Alarm and Information Messages Reference
e1061001 12-09-30 02:56:02 EST EAGLE5 45.0.0-64.44.0FTP Interface Test Test Results: PASS Server IP: 10.241.14.62 FTP Error: 0 Segment: 190004fa Diag Msg:
FTPTEST: Command Complete;
5. If the alarm is not cleared, try the FTP from another system and verify the login anddirectory. If this is unsuccessful, contact the My Oracle Support (MOS).
Recovery procedure for SNMP
In this scenario, the message typically occurs if the SNMP application loses theconnection with the host servers. The error could be caused by a network connectivityproblem or a misconfiguration of the SNMP server parameters.
1. Enter the rtrv-snmp-host command. If server is listed, verify the parameters.
Example of command and possible output:
rtrv-snmp-hostCommand entered at terminal #6.;
e1061001 12-09-30 08:58:40 EST EAGLE5 45.0.0-64.44.0IPADDR 10.25.60.20 HOST snmp-host-houston CMDPORT 161 TRAPPORT 162 HB 60 TRAPCOMM public
IPADDR 10.25.60.19 HOST snmp-host-dallas CMDPORT 161 TRAPPORT 162 HB 60 TRAPCOMM public
SNMP HOST table is (2 of 2) 100% full;
2. If the output does not show a configured SNMP host entry, configure an SNMPhost in accordance with the “Adding an FTP Server” procedure in DatabaseAdministration Manual - System Management to clear the alarm.
3. Verify connectivity with the host servers with the ping command. Enter thepass:loc=[1113 | 1115]:cmd="ping <server ipaddr>" command.
Example of command and possible output:
> pass:loc=1113:cmd="ping 10.25.60.20"
Command Accepted – Processing
e1061001 12-09-30 02:53:17 EST EAGLE5 45.0.0-64.44.0
UAMs
UAM and UIM Troubleshooting Procedures 3-27
pass:loc=1113:cmd="ping 10.25.60.20"Command entered at terminal #6.;
e1061001 12-09-30 02:53:17 EST EAGLE5 45.0.0-64.44.0PASS: Command sent to card;
e1061001 12-09-30 02:53:17 EST EAGLE5 45.0.0-64.44.0PING command in progress;
e1061001 12-09-30 02:53:18 EST EAGLE5 45.0.0-64.44.0;
e1061001 12-09-30 02:53:20 EST EAGLE5 45.0.0-64.44.0PING 10.25.60.20: 56 data bytes64 bytes from 10.25.60.20: icmp_seq=0. time=5. ms64 bytes from 10.25.60.20: icmp_seq=1. time=5. ms64 bytes from 10.25.60.20: icmp_seq=2. time=5. ms----10.25.60.20 PING Statistics----3 packets transmitted, 3 packets received, 0% packet lossround-trip (ms) min/avg/max = 5/5/5
PING command complete
If the ping test fails, verify the physical network connectivity between the EAGLEand the host servers.
4. If the alarm is not cleared, contact the My Oracle Support (MOS).
0088 - Clocks A and B TSCs are out of sync
It was detected by the OAM that clocks A and B have been out of synch for a excessiveperiod of time. This alarm indicates the clock sources being used for TSCSYNC featurehave failed or a hardware failure in the OAM card. This may impact the EAGLEIntegrated Monitoring Support feature functionality.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0** 0014.0088 ** CARD 1113 EOAM Clocks A and B are out of sync
Alarm Level: Major
Recovery
1. Check the status of the OAM card by entering the following command:
rept-stat-card:loc=xxxx
where xxxx is the card location in the output.
2. Verify the status of the system clocks with the rept-stat-clock command. IfEagle is reporting the clock alarm indicating a problem with clock sources, thencheck the status of the clock sources, the cables, and termination points. Refer to Clock System Alarms for additional details on handling clock-specific UAMs.
3. Reseat the OAM card.
4. If the problem persists, replace the OAM card.
UAMs
3-28 EAGLE Unsolicited Alarm and Information Messages Reference
Refer to Maintenance Guide for card removal/replacement procedures.
0092 - MDAL not responding
This message indicates a problem with the maintenance disk and alarm card (MDAL).
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0*C 0014.0092 *C CARD 1117 MDAL MDAL not responding
Alarm Level: Critical
Recovery
1. Check the status of the MDAL card by entering the command:
rept-stat-card:loc=x
where x is the card location stenciled on the shelf of the system.
Example of the output using card location 1117:
RLGHNCXA03W 00-09-27 16:43:42 ESTCARD VERSION TYPE APPL PST SST AST1117 ----------- MDAL -------- OOS-MT Isolated -----Command Completed.
2. Reseat the MDAL card.
3. If the problem persists, replace the MDAL card.
Refer to the Maintenance Manual, Appendix A, Card Removal/Replacement Procedures.
0099 - Incompatible HW for provisioned slot
An MPL card is in a slot provisioned for a different card type and application. Thecard is automatically inhibited.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0099 ** CARD 1201 SS7ANSI Incompatible HW for provisioned slot HW VERIFICATION CODE: xxx
Alarm Level: Major
Recovery
1. If this message contains the optional line ‘HW VERIFICATION CODE: xxx’:
a. See Hardware Verification Codes in UAMsthe section on hardware verificationcodes in the Unsolicited Alarms and Information Messages manual and decode thexxx value.
Correct the indicated problem. A card with Verification Code 002, 003, 004, or102 may possibly begin to boot continually before this alarm is displayed.
b. After correcting the problem, the card will be in out-of-service maintenance-disabled state (OOS-MT-DSBLD).
UAMs
UAM and UIM Troubleshooting Procedures 3-29
Restore the card back to in-service normal state (IS-NR) with the alw-cardcommand.
2. If this message does not contain the optional line ‘HWVERIFICATIONCODE: xxx’,perform either of the following steps:
a. Replace the MPL card with a DCM card.
Refer to the Maintenance manual for card removal/replacement procedures.
b. Re-provision the slot for a LIMDS0 card.
Refer to the Database Administration Manual - System Management manual for thecorrect procedures.
0108 - Major IMT failure detected
A major fault has been detected on one of the IMT buses. A major fault consists ofthree or more faults on the IMT bus.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0108 ** IMTBUS A Major IMT failure detected Card 1101, 1102, 1107, 1108
Alarm Level: Major
Recovery
1. Enter the following command to check the status of the IMT:
rept-stat-imt
If the entire IMT is down, continue with 6.
2. Visually check the IMTLEDS on the front of the cards.
A red LED or LEDs denotes an IMT fault. If the top LED of the pair is red, there isa fault on IMT A. If the bottom LED is red, there is a fault on IMT B. See Figure 3-1.
UAMs
3-30 EAGLE Unsolicited Alarm and Information Messages Reference
Figure 3-1 Card LEDs
3. Note the card location or locations for cards with a red LED(s).
4. Using the card location(s) noted in 3, enter the following command to connect thecard(s) back to the IMT:
conn-imt : loc =x : bus = y
where x is the card location stenciled on the shelf of the system, and y is the IMTbus to be returned to service.
UAMs
UAM and UIM Troubleshooting Procedures 3-31
The following message appears using card location 1106 and IMT bus A:
RLGHNCXA03W 00-02-07 11:02:30 EST EAGLE 35.0.0 Connect IMT Bus A command issued to card 1106
5. If the connection command is successful, the Card connected message appears.
RLGHNCXA03W 00-02-07 11:02:30 EST EAGLE 35.0.0 0100.0006 IMT BUS A Card connected to IMT
6. If the fault does not clear, enter the following command:
inh-imt:bus=x
where x = faulty IMT bus.
warning: This command removes the faulty IMT bus from service, causingall cards to disconnect from the designated bus. 8 must be completed once 6 isperformed. If the technician has any questions about using this command,contact the My Oracle Support (MOS).
7. Enter the following command to test the IMT bus:
tst-imt:bus=x
where x = the inhibited IMT bus.
An example of the output follows:
RLGHNCXA03W 97-09-27 12:47:07 EST EAGLE 35.0.0IMT Fault Isolation Bus BFault Location Probable Cause Failure(s)Card 1201 Card 1201 Pass-through Test FailedCard 1301 Card 1301 Pass-through Test Failed
Note: When tst-imt completes, either through normal termination of thecommand or because the command is aborted, 8MUST be completed.
8. Enter the following command to change the state of inhibited IMT to IS-ANR:
alw-imt:bus=x
where x = the inhibited IMT bus.
9. Reseat the affected card(s).
Probable causes are listed in order of most probable to least probable. The listedcomponents should be reseated in order listed by the output of the tst-imtcommand.
warning: Reseating or replacing a LIM will cause both links on the card tofail. If the card is a LIM, place the links on the LIM out of service by enteringthe dact-slk command.
10. If the fault does not clear, replace the affected card(s).
UAMs
3-32 EAGLE Unsolicited Alarm and Information Messages Reference
Probable causes are listed in order of most probable to least probable. The listedcomponents should be replaced in order listed by the output of the tst-imtcommand.
11. If the fault does not clear, replace the IPMX card servicing the affected card(s).
Caution: Replacing an IPMX card causes the IMT to go down. (IPMX in Slot09 affects IMT A and IPMX in Slot 10 affects IMTB.)
12. If the fault has cleared and any of these cards are LIMs, place the links assigned tothese cards back into service using the act-slk command.
13. If these steps do not clear the fault, contact the My Oracle Support (MOS).
Refer to the Maintenance manual for card removal/replacement procedures.
0111 - Failure on both IMT A and IMT B
A major fault occurred on one IMT bus and a minor fault has occurred on the other.Or, there is a minor fault on both IMT buses. A minor fault occurs when one or twocards are disconnected from the IMT bus. A major fault occurs when three or morecards are disconnected from the IMT bus.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0111 ** IMT SYSTEM Failure on both IMT A and IMT B
Alarm Level: Major
Recovery
Check the status of the IMTs by entering the rept-stat-imt command.
Contact the My Oracle Support (MOS).
0112 - Major failures detected on both IMTs
Major faults have been detected on both IMT buses.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0* C0100.0112 *C IMT SYSTEM Major failures detected on both IMTs
Alarm Level: Critical
Recovery
Check the status of the IMTs by entering the rept-stat-imt command.
Contact the My Oracle Support (MOS).
0115 - Linkset IP TPS threshold exceeded
This message indicates that the actual linkset transaction rate exceeds the provisionedlinkset IPSGTPS.
This message indicates that the actual linkset transaction rate exceeds the linksetcapacity alarm threshold defined by lsusealm, tpsalmtype, slktps
UAMs
UAM and UIM Troubleshooting Procedures 3-33
(rsvdslktps or maxslktps based on tpsalmtype) parameters and the number oflinks in the linkset.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0** 0014.0115 ** LSN lsgw1103 Linkset IP TPS threshold exceeded
Alarm Level: Major
Recovery
1. Enter this command to display the current and peak IPSGTPS utilization of thelinkset specified in the output: rept-stat-iptps
Example of the output:
eagle10115 03-05-06 09:49:20 EST EAGLE 31.6.0 IP TPS USAGE REPORT THRESH CONFIG TPS PEAK PEAKTIMESTAMP ----------------------------------------------------------------- SYSTEM CLLI1234567 100% 100000 TX: 4127 4550 03-05-05 09:49:19 RCV: 3962 4450 03-05-05 09:49:19 ----------------------------------------------------------------- LSN LSGW1101 80% 4000 TX: 3700 4000 03-05-05 09:49:19 RCV: 3650 4000 03-05-05 09:49:19 LSGW1103 80% 500 TX: 427 550 03-05-05 09:49:19 RCV: 312 450 03-05-05 09:49:19 ----------------------------------------------------------------- Command Completed.
2. Enter the rtrv-ls:lsn=xxxxxx command, where xxxxxx is the linkset name, toreview current lsusealm, tpsalmtype (TPSALM), rsvdslktps andmaxslktps parameter values and the number of links in the linkset:
Searching link set table on disk - please wait...
Command Accepted - Processing
eagle11 16-10-13 12:11:41 EST EAGLE 46.3.0.0.1-68.27.0 rtrv-ls:lsn=lab2m2pa Command entered at terminal #1.;
eagle11 16-10-13 12:11:42 EST EAGLE 46.3.0.0.1-68.27.0
L3T SLT GWS GWS GWS LSN APCN (SS7) SCRN SET SET BEI LST LNKS ACT MES DIS SLSCI NIS lab2m2pa 02000 none 1 2 no B 1 off off off no off
SPCN CLLI TFATCABMLQ MTPRSE ASL8 ---------------- ----------- 1 --- ---
SLSRSB RANDSLS ITUTFR 1 off off
IPSG IPGWAPC GTTMODE CGGTMOD PCT CHGMTP3OPC
UAMs
3-34 EAGLE Unsolicited Alarm and Information Messages Reference
yes no SysDflt no off on
ADAPTER RSVDSLKTPS MAXSLKTPS m2pa 500 500
TPSALM LSUSEALM SLKUSEALM rsvdslktps 100% 80%
LOC LINK SLC TYPE ANAME 1216 A2 0 IPSG lab2m2pa
Link set table is (16 of 1024) 2% full.
;
3. Refer to Commands User's Guide to interpret the output.
If the linkset has adequate bandwidth, then the IPTPS for the linkset can beincreased (using the chg-ls command), provided the current IPGWxIPSG systemIPTPS setting allows for this. The IPTPSLS alarm threshold percent (lsusealm) canalso be adjusted if allowed by the current setting. If the linkset does not haveadequate bandwidth, then more links or different routing strategies may berequired to correct the problem.
0120 - ENUM SYSTEM is not available
This message indicates none of the ENUM cards is Active/IS-NR.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 *C 0002.0120 *C ENUM SYSTEM ENUM SYSTEM is not available
Alarm Level: Critical.
Recovery
Activate (Active/IS-NR) any one of the ENUM cards in the system.
0121 - ENUM SYSTEM is available
This message indicates half or more of the configured ENUM cards are in IS-NR state.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 0002.0121 ENUM SYSTEM ENUM SYSTEM is available
Alarm Level: None. The message is informational only.
Recovery
No further action necessary.
0122 - ENUM SYSTEM normal, card(s) abnormal
This message indicates the Active/IS-NR number of ENUM cards is less than half ofthe configured ENUM cards.
UAMs
UAM and UIM Troubleshooting Procedures 3-35
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 ** 0002.0122 ** ENUM SYSTEM ENUM SYSTEM normal, card(s) abnormal
Alarm Level: Major.
Recovery
Activate (Active/IS-NR) half or more ENUM cards in the system.
0123 - ENUM SYSTEM is removed
This message indicates all the ENUM cards are deleted from the system.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 0002.0123 ENUM SYSTEM ENUM SYSTEM is removed
Alarm Level: None. The message is informational only.
Recovery
No further action necessary.
0124 - ENUM Threshold -Level1 exceeded
This message indicates the card TPS exceeds the configured level-1 value inENUMOPTS.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 * 0002.0124 * CARD xxxx ENUMHC ENUM Threshold -Level1 exceeded
Alarm Level: Minor.
Recovery
Reduce the card TPS below the configured level-1 value in ENUMOPTS.
0125 - ENUM Threshold -Level 2 exceeded
This message indicates the card TPS exceeds the configured level-2 value inENUMOPTS.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 ** 0002.0125 ** CARD xxxx ENUMHC ENUM Threshold –Level 2 exceeded
Alarm Level: Major.
Recovery
Reduce the card TPS below the configured level-2 value in ENUMOPTS.
UAMs
3-36 EAGLE Unsolicited Alarm and Information Messages Reference
0126 - ENUM Threshold Condition cleared
This message indicates the card TPS has been reduced to below the configured level-1value in ENUMOPTS.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 0002.0126 CARD xxxx ENUMHC ENUM Threshold Condition cleared
Alarm Level: None. The message is informational only.
Recovery
No further action necessary.
0127 - ENUM card capacity exceeded
This message indicates the card TPS exceeds the maximum allowable TPS (4000) on asingle ENUM card.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 *C 0002.0127 *C CARD xxxx ENUMHC ENUM card capacity exceeded
Alarm Level:Critical
Recovery
Reduce the card TPS below the maximum allowed card TPS.
0128 - All clocks have failed
A fault has been detected on all system clocks.
Example
RLGHNCXA21W 00-12-07 11:02:30 EST EAGLE 35.0.0*C 0100.0128 *C CLOCK SYSTEM All clocks have failed
Alarm Level: Critical
Recovery
1. Verify the status of the clock with the rept-stat-clk command.
If both clocks are idle, check the source clock into the system. Follow localmaintenance procedures to repair the source clock.
2. Verify the clock cables are connected to the shelf backplane (refer to the InstallationManual for cable location).
If any cables are loose, reconnect the cable.
3. If the clock source is not at fault, try reseating the TDM cards.
4. If the message appears again, replace the TDM cards.
Refer to the Maintenance manual for card removal/replacement procedures.
UAMs
UAM and UIM Troubleshooting Procedures 3-37
5. If the fault still does not clear, contact the My Oracle Support (MOS).
0129 - ENUM Card TPS is normal
This message indicates the card TPS is normal.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 0002.0129 CARD xxxx ENUMHC ENUM Card TPS is normal
Alarm Level: None. The message is informational only.
Recovery
No further action necessary.
0132 - Loading failed: table not found
This indicates an error in an upgrade procedure. Either an incorrect file or table wasentered. This message could also indicate the file or table being loaded is corruptedand is not recognized by the system.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0** 0014.0132 ** CARD 1304 SCCP Loading failed: table not found
Alarm Level: Major
Recovery
Contact the My Oracle Support (MOS).
0133 - Loading failed: data read Error
An error occurred on the active MASP while data tables were loaded.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0** 0014.0133 ** CARD 1304 SCCP Loading failed: data read error
Alarm Level: Major
Recovery
1. To verify that both databases are at the same level and are not corrupted, enter:
rept-stat-db
Example output for a corrupted database
bothwagm03w 99-01-08 19:52:08 EST EAGLE 35.0.0 rept-stat-lsms Command entered at terminal #1.; bothwagm03w 99-01-08 19:52:08 EST EAGLE 35.0.0 GPL PST SST AST -------------------------------------------------------------------- LSMS SYSTEM IS-NR Active -----
UAMs
3-38 EAGLE Unsolicited Alarm and Information Messages Reference
TDM TRM 8 IS-NR Active ----- TDM TRM 9 IS-NR Active ----- OAP A 023-065-000 IS-NR Active ----- OAP B 023-065-000 IS-NR Active ----- Q.3 Assoc A1 IS-NR Active ----- Q.3 Assoc B1 IS-NR Active ----- LSMS SYSTEM ALARM STATUS = No Alarms. OAP A ALARM STATUS = No Alarms. OAP B ALARM STATUS = No Alarms. Q.3 Assoc A1 ALARM STATUS = No Alarms. Q.3 Assoc B1 ALARM STATUS = No Alarms. Command Completed.;
2. To verify the integrity of the database, enter:
aud-data
3. If there is a problem with the database, follow the procedures in the DatabaseAdministration Manual - System Management for resolving database inconsistencies.
4. If the problem still exists, contact the My Oracle Support (MOS).
0134 - Loading failed: bad checksum returned
The GPL checksum, which is used to verify the data, indicates an error during filetransfer. The file (GPL) needs to be downloaded again.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0** 0014.0134 ** CARD 1304 SCCP Loading failed: bad checksum returned
Alarm Level: Major
Recovery
1. Reseat the indicated card.
This may have caused the transmission error.
2. When the card has been reseated, it attempts to reload automatically.
3. If the download fails again, contact the My Oracle Support (MOS).
0135 - Loading failed: GPL load timeout
There was a timeout caused by the loading process.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0** 0014.0135 ** CARD 1304 SCCP Loading failed: GPL load timeout
Alarm Level: Major
Recovery
1. Verify the card is properly seated.
If not, reseat the indicated card.
UAMs
UAM and UIM Troubleshooting Procedures 3-39
2. If the card is properly seated, the problem corrects itself.
No further action is necessary.
0136 - Loading failed: data load timeout
The download process timed out on the MASP. This could be caused by animproperly programmed BIP on the daughterboard of the card being loaded.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0** 0014.0136 ** CARD 1304 SCCP Loading failed: data load timeout
Alarm Level: Major
Recovery
1. Use the rtrv-bip command (debug command) to verify the BIP on the appliqueof the indicated card.
Refer to the Commands Manual for details on how to use this command.
2. If the BIP is invalid, it must be reprogrammed.
Contact the My Oracle Support (MOS). You will need to know the part number,revision level, and serial number of the card.
3. The card can be reprogrammed with instructions from the Customer Care Center,or the Customer Care Center can dial into the system and reprogram the cardremotely.
4. If the BIP is valid, reseat the card.
This should correct the problem. If not, contact the My Oracle Support (MOS).
0137 - Loading failed: invalid GPL
This message indicates that the GPL file is corrupt or there was a failure in the IMTbus.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0** 0014.0137 ** CARD 1304 SCCP Loading failed: invalid GPL
Alarm Level: Major
Recovery
1. This problem should correct itself.
2. If the problem still exists, contact the My Oracle Support (MOS).
0138 - Loading failed: GPL format error
This message indicates a corrupted GPL file.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0** 0014.0138 ** CARD 1304 SCCP Loading failed: GPL format error
UAMs
3-40 EAGLE Unsolicited Alarm and Information Messages Reference
Alarm Level: Major
Recovery
Contact the My Oracle Support (MOS).
0139 - Loading failed: disk read prep error
This message indicates the GPL version is not current, and incompatible with thesystem load.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0** 0014.0139 ** CARD 1304 SCCP Loading failed: disk read prep error
Alarm Level: Major
Recovery
Refer to the upgrade procedure sent with the software.
If this procedure was followed correctly, and the problem still exists, contact the MyOracle Support (MOS).
0140 - Loading failed: disk read response error
This message indicates there was an error in reading the fixed disk.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0** 0014.0140 ** CARD 1304 SCCP Loading failed:disk read response error
Alarm Level: Major
Recovery
1. If the disk was just installed in the system, try the load again.
2. If the problem occurs again, contact the My Oracle Support (MOS).
0141 - Loading failed: disk read failed
This message indicates there was a failure while reading the fixed disk on the activeTDM.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0** 0014.0141 ** CARD 1304 SCCP Loading failed: disk read failed
Alarm Level: Major
Recovery
1. Try the load again.
2. If the problem persists, replace the TDM with the corrupted media.
Refer to the Maintenance manual for card removal/replacement procedures.
3. If this message appears again, contact the My Oracle Support (MOS).
UAMs
UAM and UIM Troubleshooting Procedures 3-41
0152 - LIM(s) have been denied STPLAN service
This message indicates that a link interface module (LIM) has been denied STPLANservice and cannot send messages to an application communication module (ACM)due to underprovisioning. More ACMs are required. There should be approximatelyone ACM for 30-32 LIMs. However, this ratio depends upon the traffic load.
Example
RLGHNCXA21W 00-12-07 11:02:30 EST EAGLE 35.0.0** 0100.0152 ** SLAN SYSTEM LIM(s) have been denied STPLAN service
Alarm Level: Major
Recovery
1. Use the rept-stat-slan command to determine which LIMs have been deniedSTPLAN service.
Note: Make sure the problem persists. Adding new LIM cards can cause thiscondition temporarily.
2. Add ACMs one at a time.
Monitor the performance of the STPLAN subsystem with the rept-stat-slancommand to determine if additional cards are needed.
0153 - STPLAN not available
This message indicates that no application communication modules (ACMs) are inservice.
Example
RLGHNCXA21W 00-12-07 11:02:30 EST EAGLE 35.0.0*C 0100.0153 *C SLAN SYSTEM STPLAN not available
Alarm Level: Critical
Recovery
1. To determine the status of the ACMs, enter:
rept-stat-slan
Example of the output:
tekelecstp 00-04-23 13:36:07 EST EAGLE 35.0.0SLAN Subsystem Report IS-ANR Active -----SLAN Cards Configured= 2 Cards IS-NR= 2CARD VERSION PST SST AST HOST Cap. EAGLE Cap.-------------------------------------------------------------------------1206 021-010-000 IS-NR Active ---- 42% 16%1104 021-010-000 IS-NR Active ALMINH 36% 12%-------------------------------------------------------------------------AVERAGE USAGE per HOST CAPACITY = 39%AVERAGE USAGE per EAGLE CAPACITY = 14%CARDS DENIED SLAN SEVICE:
UAMs
3-42 EAGLE Unsolicited Alarm and Information Messages Reference
1101, 1204Command Completed
2. Use the init-card command to reinitialize any cards OOS-MT.
3. Enter the following command to determine if the card(s) have returned to IS-NR.
If not, reseat the card(s).rept-stat-slan
4. If any card(s) remain OOS-MT, replace the card(s).
Refer to the Maintenance Manual, Appendix A, Card Removal/Replacement Procedures.
0157 - OA&M IP Security feature risk detected
This UAM indicates the OA&M IP Security feature is currently (R46.4 or earlier) ON,and there is 1 or more FTP Servers or Telnet terminals not using SSH.
The EAGLE OA&M IP Security feature entry is used to control only the alarming if theSSH for terminals or Security of FTP Server entries is OFF. SSH for terminals andSecurity of FTP Server entries are controlled via the SECU-DFLT:SSH parameter andSECUIRTY parameter against the FTP servers entries, respectively.
Example
eagle11 17-12-07 09:22:34 EST EAGLE 46.5.0.0.0-0.0.0* 1988.0157 * SECURITY SYSTEM OA&M IP Security feature risk detected
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. To clear this alarm, either turn ON the SSH for terminals and security for all FTPsever entries, or turn the EAGLE OA&M IP Security feature OFF.
2. Run the rtrv-secu-dflt and chg-secu-dflt commands to view and modifythe SSH parameter value.
3. Run rtrv-ftp-serv and chg-ftp-serv commands to view and modify theSECURITY parameter values for the FTP servers entries.
4. Run the rtrv-ctrl-feat and chg-ctrl-feat commands to view and modifythe EAGLE OA&M IP Security feature status.
0158 - OA&M IP Security feature risk cleared
This UAM indicates the OA&M IP Security feature risk alarm has been cleared.
Example
eagle11 17-12-07 09:22:48 EST EAGLE 46.5.0.0.0-0.0.0 1991.0158 SECURITY SYSTEM OA&M IP Security feature risk cleared;
Alarm Level: No alarm condition. The message is informational only.
Recovery
No further action is necessary.
UAMs
UAM and UIM Troubleshooting Procedures 3-43
0162 - 1116-P, 1116-S clocks failed
This message indicates that both BITS clocks have failed on the TDM card located inslot 1116.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0162 ** CLOCK SYSTEM 1116-P, 1116-S clocks failed
Alarm Level: Major
Recovery
1. Use the rept-stat-clk command to determine the current clock configuration.
Example of the output:
tekelecstp 00-04-23 13:34:15 EST EAGLE 35.0.0 CARD LOC= 1114 (Standby ) CARD LOC= 1116 (Active ) PRIMARY BITS = ------ PRIMARY BITS = Fault SECONDARY BITS = ------ SECONDARY BITS = Fault PST SST AST SYSTEM CLOCK IS-NR Idle ------ # Cards using CLK A = 0 # Cards with bad CLK A = 8 # Cards using CLK B = 0 # Cards with bad CLK B = 8 # Cards using CLK I = 8 Command Completed
2. Reseat the TDM card in slot 1116.
3. If the problem persists, replace the TDM card in slot 1116.
Refer to the Maintenance manual for card removal/replacement procedures.
0164 - 1114-S, 1116-S clocks failed
This message indicates the secondary BITS clock source has failed on both the activeand standby TDM cards.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0164 ** CLOCK SYSTEM 1114-S, 1116-S clocks failed
Alarm Level: Major
Recovery
1. Use the rept-stat-clk command to determine the current clock status.
Example of the output:
tekelecstp 00-04-23 13:34:15 EST EAGLE 35.0.0 CARD LOC= 1114 (Isolated ) CARD LOC= 1116 (Active ) PRIMARY BITS = Fault PRIMARY BITS = Active SECONDARY BITS = Fault SECONDARY BITS = Fault PST SST AST SYSTEM CLOCK IS-NR ACTIVE ALMINH # Cards using CLK A = 9 # Cards with bad CLK A = 0
UAMs
3-44 EAGLE Unsolicited Alarm and Information Messages Reference
# Cards using CLK B = 0 # Cards with bad CLK B = 9 # Cards using CLK I = 0 Command Completed
2. Follow local procedures to troubleshoot and repair the secondary BITS clock.
3. If this message appears again, contact the My Oracle Support (MOS).
0166 - 1114-S, 1116-P, 1116-S clocks failed
This message indicates the following clocks failed:
• The secondary clock on the TDM card in slot 1114.
• The primary clock on the TDM card in slot 1116.
• The secondary clock on the TDM card in slot 1116.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0166 ** CLOCK SYSTEM 1114-S, 1116-P, 1116-S clocks failed
Alarm Level: Major
Recovery
1. Use the rept-stat-clk command to determine the current clock configuration.
Example of the output:
tekelecstp 00-04-23 13:34:15 EST EAGLE 35.0.0 CARD LOC= 1114 (Active ) CARD LOC= 1116 (Isolated ) PRIMARY BITS = Active PRIMARY BITS = Fault SECONDARY BITS = Fault SECONDARY BITS = Fault PST SST AST SYSTEM CLOCK IS-NR ACTIVE ALMINH # Cards using CLK A = 9 # Cards with bad CLK A = 0 # Cards using CLK B = 0 # Cards with bad CLK B = 9 # Cards using CLK I = 0 Command Completed
2. Follow local procedures to troubleshoot and repair the BITS clock.
3. If one of the reference clocks is still not functioning, replace the TDM card(s).
Refer to the Maintenance Manual,Appendix A, Card Removal/Replacement Procedures.
0169 - 1114-P, 1116-P clocks failed
This message indicates the primary BITS clock on the TDM cards in slots 1114 andslot 1116 have failed.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0169 ** CLOCK SYSTEM 1114-P, 1116-P clocks failed
Alarm Level: Major
Recovery
UAMs
UAM and UIM Troubleshooting Procedures 3-45
1. Use the rept-stat-clk command to determine the current clock configuration.
Example of the output:
tekelecstp 00-04-23 13:34:15 EST EAGLE 35.0.0 CARD LOC= 1114 (Isolated ) CARD LOC= 1116 (Active ) PRIMARY BITS = Fault PRIMARY BITS = Fault SECONDARY BITS = Fault SECONDARY BITS = Active PST SST AST SYSTEM CLOCK IS-NR ACTIVE ALMINH # Cards using CLK A = 9 # Cards with bad CLK A = 0 # Cards using CLK B = 0 # Cards with bad CLK B = 9 # Cards using CLK I = 0 Command Completed
2. Follow local procedures to troubleshoot and repair the BITS clock.
3. If one of the reference clocks is still not functioning, reseat the associated TDMcard.
Make sure the system clock reference is active on the other TDM card.
4. If one of the reference clocks is still not functioning, replace the TDM card.
Refer to the Maintenance manual for card removal/replacement procedures.
0170 - 1114-P, 1116-P, 1116-S clocks failed
This message indicates the following clocks failed:
• The primary clock on the TDM card in slot 1114.
• The primary clock on the TDM card in slot 1116.
• The secondary clock on the TDM card in slot 1116.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0170 ** CLOCK SYSTEM 1114-P, 1116-P, 1116-S clocks failed
Alarm Level: Major
Recovery
1. Use the rept-stat-clk command to determine the current clock configuration.
Example of the output:
tekelecstp 00-04-23 13:34:15 EST EAGLE 35.0.0 CARD LOC= 1114 (Standby ) CARD LOC= 1116 (Isolated ) PRIMARY BITS = ------ PRIMARY BITS = Fault SECONDARY BITS = ------ SECONDARY BITS = Active PST SST AST SYSTEM CLOCK IS-NR ACTIVE ALMINH # Cards using CLK A = 9 # Cards with bad CLK A = 0 # Cards using CLK B = 0 # Cards with bad CLK B = 9 # Cards using CLK I = 0 Command Completed
UAMs
3-46 EAGLE Unsolicited Alarm and Information Messages Reference
2. Follow local procedures to troubleshoot and repair the BITS clock.
3. If one of the reference clocks is still not functioning, reseat the associated TDMcard.
Make sure the system clock reference is active on the other TDM card.
4. If one of the reference clocks is still not functioning, replace the TDM card.
Refer to the Maintenance Manual,Appendix A, Card Removal/Replacement Procedures.
0171 - 1114-P, 1114-S clocks failed
This message indicates the primary and secondary BITS clocks on the TDM card inslot 1114 have failed.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0171 ** CLOCK SYSTEM 1114-P, 1114-S clocks failed
Alarm Level: Major
Recovery
1. Use the rept-stat-clk command to determine the current clock configuration.
Example of the output:
tekelecstp 00-04-23 13:34:15 EST EAGLE 35.0.0 CARD LOC= 1114 (Isolated ) CARD LOC= 1116 (Active ) PRIMARY BITS = Fault PRIMARY BITS = Fault SECONDARY BITS = Fault SECONDARY BITS = Active PST SST AST SYSTEM CLOCK IS-NR ACTIVE ALMINH # Cards using CLK A = 9 # Cards with bad CLK A = 0 # Cards using CLK B = 0 # Cards with bad CLK B = 9 # Cards using CLK I = 0 Command Completed
2. Follow local procedures to troubleshoot and repair the BITS clock.
3. If one of the reference clocks is still not functioning, reseat the associated TDMcard.
Make sure the system clock reference is active on the other TDM card.
4. If one of the reference clocks is still not functioning, replace the TDM card.
Refer to the Maintenance manual for card removal/replacement procedures.
0172 - 1114-P, 1114-S, 1116-S clocks failed
This message indicates the following clocks failed:
• The primary clock on the TDM card in slot 1114.
• The secondary clock on the TDM card in slot 1114.
• The secondary clock on the TDM card in slot 1116.
UAMs
UAM and UIM Troubleshooting Procedures 3-47
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0172 ** CLOCK SYSTEM 1114-P, 1114-S, 1116-S clocks failed
Alarm Level: Major
Recovery
1. Use the rept-stat-clk command to determine the current clock configuration.
Example of the output:
tekelecstp 00-04-23 13:34:15 EST EAGLE 35.0.0 CARD LOC= 1114 (Isolated ) CARD LOC= 1116 (Isolated ) PRIMARY BITS = Fault PRIMARY BITS = Fault SECONDARY BITS = Fault SECONDARY BITS = Active PST SST AST SYSTEM CLOCK IS-NR ACTIVE ALMINH # Cards using CLK A = 9 # Cards with bad CLK A = 0 # Cards using CLK B = 0 # Cards with bad CLK B = 9 # Cards using CLK I = 0 Command Completed
2. Follow local procedures to troubleshoot and repair the secondary BITS clock.
3. If one of the reference clocks is still not functioning, reseat that TDM card.
4. If one of the reference clocks is still not functioning, replace the TDM card.
Refer to the Maintenance Manual,Appendix A, Card Removal/Replacement Procedures.
0173 - 1114-P, 1114-S, 1116-P clocks failed
This message indicates the following clocks failed:
• The primary clock on the TDM card in slot 1114.
• The secondary clock on the TDM card in slot 1114.
• The primary clock on the TDM card in slot 1116.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0173 ** CLOCK SYSTEM 1114-P, 1114-S, 1116-P clocks failed
Alarm Level: Major
Recovery
1. Use the rept-stat-clk command to determine the current clock configuration.
Example of the output:
tekelecstp 00-04-23 13:34:15 EST EAGLE 35.0.0 CARD LOC= 1114 (Isolated ) CARD LOC= 1116 (Active ) PRIMARY BITS = Fault PRIMARY BITS = Fault SECONDARY BITS = Fault SECONDARY BITS = Active PST SST AST SYSTEM CLOCK IS-NR ACTIVE ALMINH
UAMs
3-48 EAGLE Unsolicited Alarm and Information Messages Reference
# Cards using CLK A = 9 # Cards with bad CLK A = 0 # Cards using CLK B = 0 # Cards with bad CLK B = 9 # Cards using CLK I = 0 Command Completed
2. Follow local procedures to troubleshoot and repair the primary BITS clock.
3. If one of the reference clocks is still not functioning, reseat the associated TDMcard.
4. If one of the reference clocks is still not functioning, replace the associated TDMcard.
Refer to the Maintenance Manual,Appendix A, Card Removal/Replacement Procedures.
0185 - 1116-PHS, 1116-SHS clocks failed
This message indicates that both E1/T1 High Speed clocks have failed for the TDMcard located in slot 1116.
Example
station1234 99-03-05 16:28:08 EST EAGLE 31.6.0 ** 0052.0185 ** HS CLOCK SYSTEM 1116-PHS, 1116-SHS clocks failed
Alarm Level: Major
Recovery
1. Use the rept-stat-clk command to determine the current clock configuration.
Example of the output:
rept-stat-clk Command entered at terminal #3.; tekelecstp 99-03-05 13:34:15 EST EAGLE 31.6.0 CARD LOC= 1114 (Active ) CARD LOC= 1116 (Isolated ) PRIMARY BITS = Active PRIMARY BITS = ----- SECONDARY BITS = Idle SECONDARY BITS = ----- HS PRIMARY CLK = Active HS PRIMARY CLK = ----- HS SECONDARY CLK = Idle HS SECONDARY CLK = ----- HS CLK TYPE = E1 UNFRAMED HS CLK TYPE = ----- HS CLK LINELEN = SHORTHAUL HS CLK LINELEN = ----- PST SST AST SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using CLK A = 009 # Cards with bad CLK A = 000 # Cards using CLK B = 000 # Cards with bad CLK B = 009 # Cards using CLK I = 000 PST SST AST HS SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using HSCLK A = 001 # Cards with bad HSCLK A = 000 # Cards using HSCLK B = 000 # Cards with bad HSCLK B = 002 # Cards using HSCLK I = 000 Command Completed.;
2. Reseat the TDM card in slot 1116.
UAMs
UAM and UIM Troubleshooting Procedures 3-49
3. If the problem persists, replace the TDM card in slot 1116.
Refer to the Maintenance manual for card removal/replacement procedures.
0187 - 1114-SHS, 1116-SHS clocks failed
This message indicates the secondary E1/T1 High Speed clock source has failed forboth the active and standby TDM cards.
Example
station1234 99-03-05 16:28:08 EST EAGLE 31.6.0 ** 0052.0187 ** HS CLOCK SYSTEM 1114-SHS, 1116-SHS clocks failed
Alarm Level: Major
Recovery
1. Use the rept-stat-clk command to determine the current clock status.
Example of the output:
rept-stat-clk Command entered at terminal #3.; tekelecstp 99-03-05 13:34:15 EST EAGLE 31.6.0 CARD LOC= 1114 (Active ) CARD LOC= 1116 (Isolated ) PRIMARY BITS = Active PRIMARY BITS = ----- SECONDARY BITS = Idle SECONDARY BITS = ----- HS PRIMARY CLK = Active HS PRIMARY CLK = ----- HS SECONDARY CLK = Idle HS SECONDARY CLK = ----- HS CLK TYPE = E1 UNFRAMED HS CLK TYPE = ----- HS CLK LINELEN = SHORTHAUL HS CLK LINELEN = ----- PST SST AST SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using CLK A = 009 # Cards with bad CLK A = 000 # Cards using CLK B = 000 # Cards with bad CLK B = 009 # Cards using CLK I = 000 PST SST AST HS SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using HSCLK A = 001 # Cards with bad HSCLK A = 000 # Cards using HSCLK B = 000 # Cards with bad HSCLK B = 002 # Cards using HSCLK I = 000 Command Completed.;
2. Follow local procedures to troubleshoot and repair the secondary E1/T1 HighSpeed clock.
3. If this message appears again, contact the My Oracle Support (MOS).
0189 - 1114-SHS, 1116-PHS,1116-SHS clocks failed
This message indicates the following High Speed clocks failed:
• The secondary High Speed clock for the TDM card in slot 1114
• The primary High Speed clock for the TDM card in slot 1116
UAMs
3-50 EAGLE Unsolicited Alarm and Information Messages Reference
• The secondary High Speed clock for the TDM card in slot 1116
Example
station1234 99-03-05 16:28:08 EST EAGLE 31.6.0 ** 0052.0189 ** HS CLOCK SYSTEM 1114-SHS, 1116-PHS,1116-SHS clocks failed
Alarm Level: Major
Recovery
1. Use the rept-stat-clk command to determine the current clock configuration.
Example of the output:
rept-stat-clk Command entered at terminal #3.; tekelecstp 99-03-05 13:34:15 EST EAGLE 31.6.0 CARD LOC= 1114 (Active ) CARD LOC= 1116 (Isolated ) PRIMARY BITS = Active PRIMARY BITS = ----- SECONDARY BITS = Idle SECONDARY BITS = ----- HS PRIMARY CLK = Active HS PRIMARY CLK = ----- HS SECONDARY CLK = Idle HS SECONDARY CLK = ----- HS CLK TYPE = E1 UNFRAMED HS CLK TYPE = ----- HS CLK LINELEN = SHORTHAUL HS CLK LINELEN = ----- PST SST AST SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using CLK A = 009 # Cards with bad CLK A = 000 # Cards using CLK B = 000 # Cards with bad CLK B = 009 # Cards using CLK I = 000 PST SST AST HS SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using HSCLK A = 001 # Cards with bad HSCLK A = 000 # Cards using HSCLK B = 000 # Cards with bad HSCLK B = 002 # Cards using HSCLK I = 000 Command Completed.
2. Follow local procedures to troubleshoot and repair the E1/T1 High Speed clocks.
3. If one of the reference clocks is still not functioning, replace the TDM card(s).
Refer to the Maintenance Manual, Appendix A, Card Removal/Replacement Procedures.
0192 - 1114-PHS, 1116-PHS clocks failed
This message indicates the primary E1/T1 High Speed clocks for the TDM cards inslots 1114 and 1116 have failed.
Example
station1234 99-03-05 16:28:08 EST EAGLE 31.6.0 ** 0052.0192 ** HS CLOCK SYSTEM 1114-PHS, 1116-PHS clocks failed
Alarm Level: Major
Recovery
1. Use the rept-stat-clk command to determine the current clock configuration.
UAMs
UAM and UIM Troubleshooting Procedures 3-51
Example of the output:
rept-stat-clk Command entered at terminal #3.; tekelecstp 99-03-05 13:34:15 EST EAGLE 31.6.0 CARD LOC= 1114 (Active ) CARD LOC= 1116 (Isolated ) PRIMARY BITS = Active PRIMARY BITS = ----- SECONDARY BITS = Idle SECONDARY BITS = ----- HS PRIMARY CLK = Active HS PRIMARY CLK = ----- HS SECONDARY CLK = Idle HS SECONDARY CLK = ----- HS CLK TYPE = E1 UNFRAMED HS CLK TYPE = ----- HS CLK LINELEN = SHORTHAUL HS CLK LINELEN = ----- PST SST AST SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using CLK A = 009 # Cards with bad CLK A = 000 # Cards using CLK B = 000 # Cards with bad CLK B = 009 # Cards using CLK I = 000 PST SST AST HS SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using HSCLK A = 001 # Cards with bad HSCLK A = 000 # Cards using HSCLK B = 000 # Cards with bad HSCLK B = 002 # Cards using HSCLK I = 000 Command Completed.;
2. Follow local procedures to troubleshoot and repair the E1/T1 High Speed clocks.
3. If one of the reference clocks is still not functioning, reseat the associated TDMcard.
Make sure the system clock reference is active on the other TDM card.
4. If one of the reference clocks is still not functioning, replace the TDM card.
Refer to the Maintenance Manual, Appendix A, Card Removal/Replacement Procedures.
0193 - 1114-PHS, 1116-PHS,1116-SHS clks failed
This message indicates the following clocks failed:
• The primary High Speed clock for the TDM card in slot 1114
• The primary High Speed clock for the TDM card in slot 1116
• The secondary High Speed clock for the TDM card in slot 1116
Example
station1234 99-03-05 16:28:08 EST EAGLE 31.6.0 ** 0052.0193 ** HS CLOCK SYSTEM 1114-PHS, 1116-PHS,1116-SHS clks failed
Alarm Level: Major
Recovery
1. Use the rept-stat-clk command to determine the current clock configuration.
Example of the output:
UAMs
3-52 EAGLE Unsolicited Alarm and Information Messages Reference
rept-stat-clk Command entered at terminal #3.; tekelecstp 99-03-05 13:34:15 EST EAGLE 31.6.0 CARD LOC= 1114 (Active ) CARD LOC= 1116 (Isolated ) PRIMARY BITS = Active PRIMARY BITS = ----- SECONDARY BITS = Idle SECONDARY BITS = ----- HS PRIMARY CLK = Active HS PRIMARY CLK = ----- HS SECONDARY CLK = Idle HS SECONDARY CLK = ----- HS CLK TYPE = E1 UNFRAMED HS CLK TYPE = ----- HS CLK LINELEN = SHORTHAUL HS CLK LINELEN = ----- PST SST AST SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using CLK A = 009 # Cards with bad CLK A = 000 # Cards using CLK B = 000 # Cards with bad CLK B = 009 # Cards using CLK I = 000 PST SST AST HS SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using HSCLK A = 001 # Cards with bad HSCLK A = 000 # Cards using HSCLK B = 000 # Cards with bad HSCLK B = 002 # Cards using HSCLK I = 000 Command Completed.
2. Follow local procedures to troubleshoot and repair the E1/T1 High Speed clocks.
3. If one of the reference clocks is still not functioning, reseat the associated TDMcard.
Make sure the system clock reference is active on the other TDM card.
4. If one of the reference clocks is still not functioning, replace the TDM card.
Refer to the Maintenance Manual, Appendix A, Card Removal/Replacement Procedures.
0194 - 1114-PHS, 1114-SHS clocks failed
This message indicates the primary and secondary E1/T1 High Speed clocks for theTDM card in slot 1114 have failed.
Example
station1234 99-03-05 16:28:08 EST EAGLE 31.6.0 ** 0052.0194 ** HS CLOCK SYSTEM 1114-PHS, 1114-SHS clocks failed
Alarm Level: Major
Recovery
1. Use the rept-stat-clk command to determine the current clock configuration.
Example of the output:
rept-stat-clk Command entered at terminal #3.; tekelecstp 99-03-05 13:34:15 EST EAGLE 31.6.0 CARD LOC= 1114 (Active ) CARD LOC= 1116 (Isolated ) PRIMARY BITS = Active PRIMARY BITS = -----
UAMs
UAM and UIM Troubleshooting Procedures 3-53
SECONDARY BITS = Idle SECONDARY BITS = ----- HS PRIMARY CLK = Active HS PRIMARY CLK = ----- HS SECONDARY CLK = Idle HS SECONDARY CLK = ----- HS CLK TYPE = E1 UNFRAMED HS CLK TYPE = ----- HS CLK LINELEN = SHORTHAUL HS CLK LINELEN = ----- PST SST AST SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using CLK A = 009 # Cards with bad CLK A = 000 # Cards using CLK B = 000 # Cards with bad CLK B = 009 # Cards using CLK I = 000 PST SST AST HS SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using HSCLK A = 001 # Cards with bad HSCLK A = 000 # Cards using HSCLK B = 000 # Cards with bad HSCLK B = 002 # Cards using HSCLK I = 000 Command Completed.;
2. Follow local procedures to troubleshoot and repair the E1/T1 High Speed clocks.
3. If one of the reference clocks is still not functioning, reseat the associated TDMcard.
Make sure the system clock reference is active on the other TDM card.
4. If one of the reference clocks is still not functioning, replace the TDM card.
Refer to the Maintenance Manual, Appendix A, Card Removal/Replacement Procedures.
0195 - 1114-PHS, 1114-SHS,1116-SHS clks failed
This message indicates the following clocks failed:
• The primary High Speed clock for the TDM card in slot 1114
• The secondary High Speed clock for the TDM card in slot 1114
• The secondary High Speed clock for the TDM card in slot 1116
Example
station1234 99-03-05 16:28:08 EST EAGLE 31.6.0 ** 0052.0194 ** HS CLOCK SYSTEM 1114-PHS, 1114-SHS clocks failed
Alarm Level: Major
Recovery
1. Use the rept-stat-clk command to determine the current clock configuration.
Example of the output:
rept-stat-clk Command entered at terminal #3.; tekelecstp 99-03-05 13:34:15 EST EAGLE 31.6.0 CARD LOC= 1114 (Active ) CARD LOC= 1116 (Isolated ) PRIMARY BITS = Active PRIMARY BITS = ----- SECONDARY BITS = Idle SECONDARY BITS = -----
UAMs
3-54 EAGLE Unsolicited Alarm and Information Messages Reference
HS PRIMARY CLK = Active HS PRIMARY CLK = ----- HS SECONDARY CLK = Idle HS SECONDARY CLK = ----- HS CLK TYPE = E1 UNFRAMED HS CLK TYPE = ----- HS CLK LINELEN = SHORTHAUL HS CLK LINELEN = ----- PST SST AST SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using CLK A = 009 # Cards with bad CLK A = 000 # Cards using CLK B = 000 # Cards with bad CLK B = 009 # Cards using CLK I = 000 PST SST AST HS SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using HSCLK A = 001 # Cards with bad HSCLK A = 000 # Cards using HSCLK B = 000 # Cards with bad HSCLK B = 002 # Cards using HSCLK I = 000 Command Completed.
2. Follow local procedures to troubleshoot and repair the secondary E1/T1 HighSpeed clock.
3. If one of the reference clocks is still not functioning, reseat that TDM card.
4. If one of the reference clocks is still not functioning, replace the TDM card.
Refer to the Maintenance Manual, Appendix A, Card Removal/Replacement Procedures.
0196 - 1114-PHS, 1114-SHS,1116-PHS clks failed
This message indicates the following clocks failed:
• The primary High Speed clock for the TDM card in slot 1114
• The secondary High Speed clock for the TDM card in slot 1114
• The primary High Speed clock for the TDM card in slot 1116
Example
station1234 99-03-05 16:28:08 EST EAGLE 31.6.0 ** 0052.0196 ** HS CLOCK SYSTEM 1114-PHS, 1114-SHS,1116-PHS clks failed
Alarm Level: Major
Recovery
1. Use the rept-stat-clk command to determine the current clock configuration.
Example of the output:
rept-stat-clk Command entered at terminal #3.; tekelecstp 99-03-05 13:34:15 EST EAGLE 31.6.0 CARD LOC= 1114 (Active ) CARD LOC= 1116 (Isolated ) PRIMARY BITS = Active PRIMARY BITS = ----- SECONDARY BITS = Idle SECONDARY BITS = ----- HS PRIMARY CLK = Active HS PRIMARY CLK = ----- HS SECONDARY CLK = Idle HS SECONDARY CLK = ----- HS CLK TYPE = E1 UNFRAMED HS CLK TYPE = ----- HS CLK LINELEN = SHORTHAUL HS CLK LINELEN = -----
UAMs
UAM and UIM Troubleshooting Procedures 3-55
PST SST AST SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using CLK A = 009 # Cards with bad CLK A = 000 # Cards using CLK B = 000 # Cards with bad CLK B = 009 # Cards using CLK I = 000 PST SST AST HS SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using HSCLK A = 001 # Cards with bad HSCLK A = 000 # Cards using HSCLK B = 000 # Cards with bad HSCLK B = 002 # Cards using HSCLK I = 000 Command Completed.;
2. Follow local procedures to troubleshoot and repair the primary E1/T1 High Speedclock.
3. If one of the reference clocks is still not functioning, reseat the associated TDMcard.
4. If one of the reference clocks is still not functioning, replace the associated TDMcard.
Refer to the Maintenance Manual, Appendix A, Card Removal/Replacement Procedures.
0197 - All high speed clocks have failed
A fault has been detected on all high speed system clocks.
Example
RLGHNCXA21W 00-12-07 11:02:30 EST EAGLE 31.6.0*C 0100.0197 *C HS CLOCK SYSTEM All high speed clocks have failed
Alarm Level: Critical
Recovery
1. Verify the status of the clock with the rept-stat-clk command.
If both clocks are idle, check the source clock into the system. Follow localmaintenance procedures to repair the source clock.
2. Verify the clock cables are connected to the shelf backplane (refer to the InstallationManual for cable location).
If any cables are loose, reconnect the cable.
3. If the clock source is not at fault, try reseating the TDM cards.
4. If the message appears again, replace the TDM cards.
Refer to the Maintenance manual for card removal/replacement procedures.
5. If the fault still does not clear, contact the My Oracle Support (MOS).
0201 - REPT-LKF: remote NE loopback
This message indicates the link is in loopback. This alarm is repeated every 15 minutesuntil the loopback is deactivated.
UAMs
3-56 EAGLE Unsolicited Alarm and Information Messages Reference
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0201 ** SLK 1205,A nc00027 REPT-LKF:remote NE loopback SLC=01 FECLLI=A1234567890 CLASS=MTP2
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
If the loopback was established in error, enter the following command, specifying thelocation and port from the output message:
dact-lbp:loc=xxxx:port=y
where xxxx = the card location from the outputy = the port A or B from the output.
0202 - REPT-LKF: HWP - too many link interrupts
This message indicates the link has had numerous interruptions.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.202 ** SLK 1205,A nc00027 REPT-LKF:HWP - too many link interrupts SLC=01 FECLLI=A1234567890 CLASS=SAAL
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
1. The number of interruptions has exceeded the threshold.
This situation can be caused by excessive noise from unshielded cables, loose ordisconnected cables.
2. Check the physical connections to the specified card.
3. Follow local procedures to test the link facilities.
0203 - REPT-LKF: lost data
The signaling link has lost data.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0203 ** SLK 1205,A nc00027 REPT-LKF:lost data SLC=03 FECLLI=testclli CLASS=MTP2
Note: The Class parameter in the example is optional.
Alarm Level: Major
UAMs
UAM and UIM Troubleshooting Procedures 3-57
Recovery
1. Check the physical connections to the signaling link.
2. Using an analyzer, test for level 1 and level 2 functions.
Follow local procedures to test and return links to service.
0204 - REPT-LKF: XER - ERM threshold exceeded
The signal unit error rate monitor (ERM) has exceeded the threshold because there aretoo many errors on the link.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0204 ** SLK 1205,A nc00027 REPT-LKF:XER-ERM threshold exceeded SLC=01 FECLLI=A1234567890 CLASS=SAAL
Alarm Level: Major
Recovery
Follow local procedures to test the link facilities.
0205 - REPT-LKF: APF - lvl-2 T1 expd (ready)
The signaling link did not receive a fill-in or message signal unit after the provingperiod.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0313.0205 ** SLK 1205,A nc00027 REPT-LKF:APF-lvl-2 T1 expd (ready) SLC=03 FECLLI=testclli CLASS=MTP2
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
If the problem persists, follow local procedures to determine why the far-end is notresponding correctly.
0206 - REPT-LKF: APF - lvl-2 T1 expd (not ready)
The signaling link did not receive a fill-in or message signal unit after the provingperiod.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0313.0206 ** SLK 1205,A nc00027 REPT-LKF:APF - lvl-2 T1 expd (not ready) SLC=01 FECLLI=A1234567890 CLASS=SAAL
Note: The Class parameter in the example is optional.
Alarm Level: Major
UAMs
3-58 EAGLE Unsolicited Alarm and Information Messages Reference
Recovery
1. If the problem persists, follow local procedures to determine why the far-end is notresponding correctly.
0207 - REPT-LKF: APF - lvl-2 T3 expired
The link did not receive an SIN or an SIE before the T3 timer expired.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0207 ** SLK 1205,A nc00027 REPT-LKF:APF - lvl-2 T3 expired SLC=03 FECLLI=testclli CLASS=MTP2
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
If the problem persists, follow local procedures to determine why the far-end is notresponding correctly.
0208 - REPT-LKF: APF - lvl-2 T2 expired
The link did not receive an SIN, SIE, or SIOS.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0208 ** SLK 1205,A nc00027 REPT-LKF:APF - lvl-2 T2 expired SLC=03 FECLLI=testclli CLASS=SAAL
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
If the problem persists, follow local procedures to determine why the far-end is notresponding correctly.
0209 - REPT-LKF: APF - failed proving period
The signaling link has failed the proving period.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0209 ** SLK 1205,A nc00027 REPT-LKF: APF - failed proving period SLC=03 FECLLI=testclli CLASS=MTP2
Note: The Class parameter in the example is optional.
Alarm Level: Major
UAMs
UAM and UIM Troubleshooting Procedures 3-59
Recovery
If the problem persists, follow local procedures to determine why the far-end is notresponding correctly.
0210 - REPT-LKF: OSA - received SIO
The signaling terminal has received the status indication Out of Alignment from thefar end.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0210 ** SLK 1205,A nc00027 REPT-LKF: OSA - received SIO SLC=03 FECLLI=testclli CLASS=SAAL
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
If the problem persists, follow local procedures to determine why the far-end is notresponding correctly.
0211 - REPT-LKF: OSA - received SIN
The signaling terminal has received the status indication normal proving from the farend.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0211 ** SLK 1205,A nc00027 REPT-LKF: OSA - received SIN SLC=03 FECLLI=testclli CLASS=MTP2
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
If the problem persists, follow local procedures to determine why the far-end is notresponding correctly.
0212 - REPT-LKF: OSA - received SIE
The signaling terminal has received the status indication emergency alignment, fromthe far end.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0212 ** SLK 1205,A nc00027 REPT-LKF: OSA - received SIE SLC=03 FECLLI=testclli CLASS=SAAL
Note: The Class parameter in the example is optional.
UAMs
3-60 EAGLE Unsolicited Alarm and Information Messages Reference
Alarm Level: Major
Recovery
If the problem persists, follow local procedures to determine why the far-end is notresponding correctly.
0213 - REPT-LKF: OSA - received SIOS
The signaling link has received the status indication out of service from the far end.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0213 ** SLK 1205,A nc00027 REPT-LKF: OSA - received SIOS SLC=03 FECLLI=testclli CLASS=MTP2
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
If the problem persists, follow local procedures to determine why the far-end is notresponding correctly.
0214 - REPT-LKF: ABN - rcvd 2 of 3 invalid BSN
The link has received 2 out of 3 invalid backward sequence numbers (BSNs) from thefar end.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0214 ** SLK 1205,A nc00027 REPT-LKF: ABN - rcvd 2 of 3 invalid BSN SLC=03 FECLLI=testclli CLASS=SAAL
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
If the problem persists, follow local procedures to determine why the far-end is notresponding correctly.
0215 - REPT-LKF: ABN - rcvd 2 of 3 invalid FIB
The signaling link has received 2 out of 3 invalid forward indicator bits (FIB) from thefar end.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0215 ** SLK 1205,A nc00027 REPT-LKF: ABN-rcvd 2 of 3 invalid FIB SLC=03 FECLLI=testclli CLASS=MTP2
Note: The Class parameter in the example is optional.
UAMs
UAM and UIM Troubleshooting Procedures 3-61
Alarm Level: Major
Recovery
If the problem persists, follow local procedures to determine why the far-end is notresponding correctly.
0216 - REPT-LKF: remote congestion timeout
The remote node has been in congestion too long. The T6 timer has timed out.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0216 ** SLK 1205,A nc00027 REPT-LKF:remote congestion timeout SLC=03 FECLLI=testclli CLASS=SAAL
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
If the problem persists, follow local procedures to determine why the far end is notresponding correctly.
1. Enter rept-stat-card:mode=full:loc=xxxx to determine if the signalinglink is M2PA. If so, continue to 2. If not, skip to 3.
2. If this alarm is raised for IPSG M2PA signaling links, do the following:
a. Enter the rept-stat-iptps and msucount –l commands to determine howmuch traffic is received and transmitted on the M2PA links.
b. Enter the rtrv-ls command to determine the amount of rsvdslktps andmaxslktps traffic that the M2PA signaling link can receive based on what isprovisioned. (The rsvdslktps is the reserved-per-signaling-link TPS for IPSGlinkset; this indicates the minimum guaranteed capacity for each link in thelinkset. The maxslktps is the maximum-per-signaling-link TPS; this indicatesthe maximum traffic permitted when sufficient unused capacity is present onthe host card.)
c. Determine if the value exceeds the incoming traffic rate that the near end canaccept. If the value is incorrect, enter the chg-ls command to increase ordecrease the minimum and maximum TPS for the M2PA signaling link.
Note: This step applies to only IPSG M2PA links and not to IPLIM M2PAlinks.
3. If the problem persists, follow local procedures to determine why the far end is notresponding correctly.
0217 - REPT-LKF: XDA - excess acknowledge delay
The T7 timer has timed out. Either there is too much incoming traffic on M2PAsignaling links, or the far end node is taking too long to acknowledge the messagessent to it by the signaling terminal.
UAMs
3-62 EAGLE Unsolicited Alarm and Information Messages Reference
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0217 ** SLK 1205,A nc00027 REPT-LKF: XDA-excess acknowledge delay SLC=03 FECLLI=testclli CLASS=MTP2
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
1. Enter rept-stat-card:mode=full:loc=xxxx to determine if the signalinglink is M2PA. If so, continue to 2. If not, skip to 3.
2. If this alarm is raised for M2PA signaling links, do the following:
a. Enter the rept-stat-iptps and msucount –l commands to determine howmuch traffic is received and transmitted on the M2PA links.
b. Enter the rtrv-ls command to determine the amount of rsvdslktps andmaxslktps traffic that the M2PA signaling link can receive based on what isprovisioned. (The rsvdslktps is the reserved-per-signaling-link TPS for IPSGlinkset; this indicates the minimum guaranteed capacity for each link in thelinkset. The maxslktps is the maximum-per-signaling-link TPS; this indicatesthe maximum traffic permitted when sufficient unused capacity is present onthe host card.)
c. If the value is incorrect to handle the incoming traffic rate, enter the chg-lscommand to increase or decrease the minimum and maximum TPS for theM2PA signaling link.
3. If the problem persists, follow local procedures to determine why the far end is notresponding correctly.
0218 - REPT-LKF: COO - rcvd changeover order
The signaling link has received a changeover order from the far end.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0218 ** SLK 1205,A nc00027 REPT-LKF:COO-rcvd changeover order SLC=03 FECLLI=testclli CLASS=SAAL
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
If the problem persists, follow local procedures to determine why the far-end is notresponding correctly.
UAMs
UAM and UIM Troubleshooting Procedures 3-63
0219 - REPT-LKF: false congestion restart
This message indicates the signaling link has entered a congestion state even thoughthe traffic on the linkset is not high enough to cause congestion. For example, if thelink has a high number of retransmissions, the throughput on the link could dropenough to cause congestion on the link. A T31 timer has started. If the link stays incongestion for a specified period, the link is restarted.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0** 0014.0219 ** SLK 1205,A nc00027 REPT-LKF:false congestion restart SLC=03 FECLLI=testclli CLASS=MTP2
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
1. Activate measurements using the chg-meas:collect=on command.
This starts measurements collection.
2. If the link is placed OOS-MT, use the measurements collected over the appropriatetime period to determine the cause, and determine which action is now necessary.
Note: Refer to the Measurements Manual for traffic measurements information.
0220 - REPT-LKF: MTP link restart delayed
This message indicates that a link has gone in and out-of-service. To avoid links goingin and out-of-service repeatedly, the EAGLE system uses level 3 T32 timer procedure,which delays restarting a link if the link has an unstable history.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0220 ** SLK 1205,A nc00027 REPT-LKF:MTP link restart delayed SLC=03 FECLLI=testclli CLASS=SAAL
Note: The Class parameter in the example is optional. SS7IPGW and IPLIMlinks are considered high-speed links by the EAGLE 5 ISS system. They arereported as CLASS=SAAL.
Alarm Level: Major
Recovery
The link should become available.
If the problem persists, contact the My Oracle Support (MOS).
UAMs
3-64 EAGLE Unsolicited Alarm and Information Messages Reference
0222 - REPT-LKF: remote FE loopback
This message indicates that the specified link has been looped back from the far-end.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0222 ** SLK 1205,A nc00027 REPT-LKF:remote FE loopback SLC=03 FECLLI=testclli CLASS=MTP2
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
If you wish to stop the loopback testing, notify the far-end to stop the testing.
0224 - REPT-LKF: link test failed
This message indicates that the specified link was automatically removed from service(OOS) because of a failed signaling link test.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0224 ** SLK 1205,A nc00027 REPT-LKF:link test failed SLC=03 FECLLI=testclli CLASS=MTP2
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
1. Check the physical connections to the signaling link.
2. Follow local procedures to check link data at both ends.
3. Using an analyzer, test for level 1 and level 2 functions.
Follow local procedures to test and return links to service.
0230 - REPT-LKF: local blocked - thermal
All links to the HC MIM are blocked because the the temperature of the HC MIM isabove operational limits.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0230 ** SLK 1205,A nc00027 REPT-LKF: local blocked - thermal SLC=03 FECLLI=testclli CLASS=MTP2
Alarm Level: Major
Recovery
Review the output.
UAMs
UAM and UIM Troubleshooting Procedures 3-65
Correct the associated alarms to clear this alarm.
0232 - REPT-LKF: remote blocked
The link is blocked due to an event at the far-end.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0232 ** SLK 1205,A nc00027 REPT-LKF: remote blocked SLC=03 FECLLI=testclli CLASS=MTP2
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
Contact the far-end office to verify a processor outage and correct.
0233 - REPT-LINK-MANUAV: local blocked
A local technician has put the signaling link in processor outage.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0233 ** SLK 1205,A nc00027 REPT-LINK-MANUAV: local blocked SLC=03 FECLLI=testclli CLASS=SAAL
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
1. Verify the condition is not intentional.
If it is not intentionally blocked, enter the following command to place the link inservice: ublk-slk:loc=xxxx:port=y where xxxx is the card location y is theport
2. This should place the processor back into service.
The following message should appear.
RLGHNCXA03W 00-02-07 11:11:28 EST EAGLE 35.0.0Local processor outage being cleared.
0234 - REPT-LKF: RMI remote inhibited
The link has been remotely inhibited by a technician at the far-end office.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0234 ** SLK 1205,A nc00027 REPT-LKF: RMI remote inhibited SLC=03 FECLLI=testclli CLASS=MTP2
UAMs
3-66 EAGLE Unsolicited Alarm and Information Messages Reference
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
Contact the far-end office to verify the reason for inhibiting the link.
0235 - REPT-LINK-MGTINH: local inhibited
The link has been inhibited locally by a technician.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0235 ** SLK 1205,A nc00027 REPT-LINK-MGTINH: local inhibited SLC=03 FECLLI=testclli CLASS=SAAL
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
1. Ensure the link should not be inhibited.
Enter the following command to place the link in service:
unhb-slk:loc=xxxx:port=y
where xxxx is the card location y is the port
2. The link should begin transmitting and receiving MSUs.
The following message should appear.
RLGHNCXA03W 00-02-07 11:11:28 EST EAGLE 35.0.0Allow link message sent to card.
0236 - REPT-LKF: not aligned
The signaling link has lost alignment. It can no longer carry traffic.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0236 ** SLK 1205,A nc00027 REPT-LKF: not aligned SLC=03 FECLLI=testclli CLASS=MTP2
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
1. Put the link into a local loopback state.
UAMs
UAM and UIM Troubleshooting Procedures 3-67
2. If the link does not align, enter the following command to determine the status ofthe card:
rept-stat-card
3. If the card has reinitialized, the system software will restore the card.
If both links on the card are out of service, but the card is IS-NR (In-Service-Normal), reseat the card.
4. If the links restore after reseating the card, this procedure is complete.
5. If the links do not restore after reseating the card, enter the following command:
rmv-card:loc=xxxx
where xxxx = the card location.
6. After the command is complete, enter the following command:
rst-card:loc=xxxx
where xxxx = the card location.
7. If the links restore after restoring the card, this procedure is complete.
8. If the fault does not clear, replace the indicated card.
Refer to the Maintenance manual for card removal/replacement procedures.
9. If the link aligns when it is in a loopback state, enter the following command todetermine the DPC of the far end office:
rtrv-slk:loc=xxxx
where xxxx = the card location. Contact the far end office to determine if the troubleis at that end.
10. If the fault does not clear, determine if any other links on the same carrier areaffected.
If other links on the same carrier are affected, you may have trouble in your carrier.
11. Using measurements, review the activity over the last day and determine if therewere a number of retransmits, message losses and so forth.
Use this data to isolate the problem to the appropriate level (MTP level 2, MTPlevel 3, and so forth). Use your company maintenance procedures for testing andclearing faults in carriers.
0237 - REPT-LKF: LM Timer NO-CREDIT expired
The remote node has held the local node in a no-credit state for too long.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0237 ** SLK 1205,A nc00027 REPT-LKF: LM Timer NO-CREDIT expired SLC=03 FECLLI=testclli CLASS=SAAL
Note: The Class parameter in the example is optional.
UAMs
3-68 EAGLE Unsolicited Alarm and Information Messages Reference
Alarm Level: Major
Recovery
Contact the far-end office to test and correct the link congestion problem.
0238 - REPT-LKF: XDA-Timer NO-RESPONSE expired
The far end is not responding to the outgoing POLL messages.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0238 ** SLK 1205,A nc00027 REPT-LKF: Timer NO-RESPONSE expired SLC=03 FECLLI=testclli CLASS=MTP2
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
Contact the far-end office to determine why no STAT messages are being sent.
0239 - REPT-LKF: MBL-local processor outage
Indicates a spontaneous or management-initiated processor outage.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0239 ** SLK 1205,A nc00027 REPT-LKF:MBL - local processor outage SLC=03 FECLLI=testclli CLASS=MTP2
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
1. Enter the following command to determine whether the outage was spontaneousor management-initiated:
rept-stat-slk:l2stats=both
2. Analyze the output.
If the processor outage was spontaneous, contact the My Oracle Support (MOS).
0240 - REPT-LKF: rcvd remote processor outage
The far end sent an END processor outage protocol data unit (PDU).
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0240 ** SLK 1205,A nc00027 REPT-LKF: rcvd remote processor outage SLC=03 FECLLI=testclli CLASS=MTP2
UAMs
UAM and UIM Troubleshooting Procedures 3-69
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
Contact the far-end office to verify a processor outage and the cause.
0241 - REPT-LKF: rcvd remote out of service
The far end sent an END out of service protocol data unit (PDU).
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0241 ** SLK 1205,A nc00027 REPT-LKF: rcvd remote out of service SLC=03 FECLLI=testclli CLASS=MTP2
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
Contact the far-end office to correct the problem.
0242 - REPT-LKF:rcvd remote protocol error
A protocol error has occurred on the far end.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0242 ** SLK 1205,A nc00027 REPT-LKF:rcvd remote protocol error SLC=03 FECLLI=testclli CLASS=MTP2
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
Contact the far-end office to test and correct the problem.
0243 - REPT-LKF:rcvd remote mgmt inititated
The MAAL layer (not a user) on the far end released a link.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0243 ** SLK 1205,A nc00027 REPT-LKF:rcvd remote mgmt inititated SLC=03 FECLLI=testclli CLASS=MTP2
Note: The Class parameter in the example is optional.
UAMs
3-70 EAGLE Unsolicited Alarm and Information Messages Reference
Alarm Level: Major
Recovery
Contact the far-end office for the details about releasing the link.
0244 - REPT-LKF: FAC – DS1/E1 LOS failure
A level 1 facility outage: loss of signal.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0244 ** SLK 1205,A nc00027 REPT-LKF: FAC – DS1/E1 LOS failure SLC=03 FECLLI=testclli CLASS=MTP2
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
1. Enter the following command to display the service data:
rept-stat-slk:l2stats=both
2. Check the physical connections to the signaling link.
3. Using an analyzer, test for level 1 and level 2 functions.
Follow local procedures to test and return links to service.
0245 - REPT-LKF: FAC – DS1/E1 LOF failure
A level 1 facility outage: loss of frame.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0245 ** SLK 1205,A nc00027 REPT-LKF: FAC – DS1/E1 LOF failure SLC=03 FECLLI=testclli CLASS=MTP2
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
1. Enter the following command to display the service data:
rept-stat-slk:l2stats=both
2. Check the physical connections to the signaling link.
3. Using an analyzer, test for level 1 and level 2 functions.
Follow local procedures to test and return links to service.
UAMs
UAM and UIM Troubleshooting Procedures 3-71
0246 - REPT-LKF: FAC – DS1/E1 LCD failure
A level 1 facility outage: loss of cell delineation.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0246 ** SLK 1205,A nc00027 REPT-LKF: FAC – DS1/E1 LCD failure SLC=03 FECLLI=testclli CLASS=MTP2
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
1. Enter the following command to display the service data:
rept-stat-slk:l2stats=both
2. Check the physical connections to the signaling link.
3. Using an analyzer, test for level 1 and level 2 functions.
Follow local procedures to test and return links to service.
0247 - REPT-LKF: XER - ISERM threshold exceeded
The in-service error rate monitor (ISERM) maintains a counter to estimate the PDUerror rate. The ISERM counter exceeded the estimated threshold.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0247 ** SLK 1205,A nc00027 REPT-LKF:XER - ISERM threshold exceeded SLC=03 FECLLI=testclli CLASS=MTP
Note: The Class parameter in the example is optional.
Alarm Level: Major
Recovery
Contact the far-end office to determine why the error rate is so high.
0248 - DDL Unstable
This alarm indicates the DDL unstable has been detected.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 ** 0002.0248 ** Card 1212 DDL Unstable
Alarm Level: Major
UAMs
3-72 EAGLE Unsolicited Alarm and Information Messages Reference
Recovery
Contact Customer Service.
0249 - DDL Stable
This indicates the DDL is no longer unstable.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 0002.0249 * Card 1212 DDL Stable
Alarm Level: None
No further action necessary.
0261 - MPS unavailable
This message indicates that the EAGLE 5 ISS system is unable to communicate withthe MPS or the MPS has an internal failure.
Example
station1234 99-03-30 16:28:08 EST EAGLE 35.0.0*C 3535.0261 *C MPS A MPS unavailable
Alarm Level: Critical
Recovery
1. This message reports that communication with the MPS is not occurring.
You should verify the MPS is operating and the IP link is functioning byperforming the following steps.
2. Verify the IP connection from the MPS to Eagle is operating.
If not, restore the communication link between the them.
3. Once the communications link with the MPS is assured, verify the status of theMPS.
The following example shows a possible system response when a specified DSMcard is queried with the rept-stat-mps command. rept-stat-mps:loc=1205
rlghncxa03w 01-03-07 10:23:93 EST EAGLE 35.0.0 CARD VERSION TYPE PST SST AST 1205 ----------- DSM OOS-MT-DSBLD Manual ----- DSM PORT A OOS-MT Unavail ----- ALARM STATUS = ** 0084 IP Connection Unavailable DSM PORT B OOS-MT Unavail ----- ALARM STATUS = ** 0084 IP Connection Unavailable INP STAT = ------- CARD ALARM STATUS = No Alarms. DSM MEMORY USAGE = 0% Command Completed. ;
UAMs
UAM and UIM Troubleshooting Procedures 3-73
Determine from the output whether the MPS is active and available for service. If itis not, refer to the ELAP Administration and LNP Feature Actiivation or EPAPAdministration Manual about restoring an MPS server to the active state.
0262 - GTT Duplicate Actn processing stopped
The Service Module card received too many MSUs requiring GTT Duplicate Actionsat one time. As a result, the Service Module card was generating more duplicate MSUsthan the card could handle. To prevent the number of duplicates from overwhelmingthe Service Module card, the card stopped processing GTT Duplicate Actions.
Example
** 0002.0262 ** SCCP SYSTEM GTT Duplicate Actn processing stopped Service: GTT
Alarm Level: Major
Recovery
The Service Module card will begin processing GTT Duplicate Actions again with nofurther action. To prevent the problem from occurring again, do the following:
1. Run the rept-stat-sccp command to see the location of the Service Modulecards that are not processing GTT Duplicate Actions. Note that this command doesnot display the GTT Actions that resulted in the disabling of GTT DuplicateActions.
2. To reduce the chance of the overwhelming the Service Module card, do one of thefollowing:
• Provision fewer GTT Duplicate Actions so that the Service Module card doesnot generate excess duplicate messages.
• Rearrange the location of LIM and Service Module cards so that the traffic isevenly distributed among the Service Module cards.
0276 - Insufficient HW for IP7 provisioning
The DCM or EDCM does not have enough memory to provision for sockets andassociations.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0276 ** CARD 1115 DCM Insufficient HW for IP7 provisioning HW VERIFICATION CODE: xxx
Alarm Level: Major
Recovery
1. If this message contains the optional line ‘HW VERIFICATIONCODE: xxx’:
a. Decode the xxx value and correct the indicated problem.
See Hardware Verification Codes in UAMsthe section on hardware verificationcodes in the Unsolicited Alarms and Information Messages manual.
b. After correcting the problem, the card will be in out-of-service maintenancedisabled state (OOS-MT-DSBLD).
UAMs
3-74 EAGLE Unsolicited Alarm and Information Messages Reference
Restore the card back to in-service normal state (IS-NR) with the alw-cardcommand.
If this message does not contain the optional line ‘HW VERIFICATIONCODE: xxx’,continue with the next step.
2. Verify the DCM/EDCM hardware.
Verify the provisioning rules.
Table 3-3 Maximum Sockets/Associations per Card
Card TypeSocket toAssociation Ratio
MaximumAssociations Maximum Sockets
DCM 8:1 50 4
EDCM 1:1 50 50
3. If necessary, reduce the number of associations to four or less for DCMs or 50 orless for EDCMs.
Refer to the Database Administration Manual - IP7 Secure Gateway for detailedprovisioning information.
0277 - AS Unavailable
This Application Server (AS) is not available to carry service traffic. All ASPs in thisAS are not available to carry service traffic.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0277 ** IP7 as3 AS Unavailable
Alarm Level: Major
Recovery
1. If the connection is in service, enter this command to generate a report of the ASassociation status: rept-stat-as:asname="application_server_name"
2. If the connection is not in service, there is nothing more you can do to fix theproblem without further information from the far end, because the far end node isin control of this state.
0283 - LNP Ported LRNs approaching Feat. Cap.
The number of LNP ported LRNs is greater than the capacity this feature supports.
This UAM appears when the DSMVSCCP cards are cold-restarted after theELAPRTDBs were pre-populated offline with LRN totals that exceed the LRNQuantity Feature keys capacities that are currently configured for the EAGLE 5 ISS.
Example
RLGHNCXA21W 03-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0283 ** CARD 1115 DCM LNP Ported LRNs approaching Feat. Cap.
Alarm Level: Major
UAMs
UAM and UIM Troubleshooting Procedures 3-75
Recovery
1. Enter the following command to verify the quantity of LRNs specified for thissystem:
rtrv-ctrl-feat
2. Either reduce the number of LRNs to the level specified by the output of 1, orrespecify the capacity with the enable-ctrl-feat command.
0285 - LNP Ported NPAs approaching Feat. Cap.
The number of LNP ported NPANXXs is greater than the capacity this featuresupports.
This UAM appears when the DSMVSCCP cards are cold-restarted after theELAPRTDBs were pre-populated offline with NPANXX totals that exceed theNPANXX Quantity Feature keys capacities that are currently configured for theEAGLE 5 ISS.
Example
RLGHNCXA21W 03-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0285 ** CARD 1115 DCM LNP Ported NPAs approaching Feat. Cap.
Alarm Level: Major
Recovery
1. Enter the following command to verify the quantity of NPANXXs specified for thissystem:
rtrv-ctrl-feat
2. Either reduce the number of NPANXXs to the level specified by the output of 1, orrespecify the capacity with the enable-ctrl-feat command.
0287 - RTDB Table Level 2 FAK Cap Exceeded
This UAM warns the customer that the total TNs in the LNP database has reached95% of the LNP database Feature Access Key (FAK) capacity.
Example
RLGHNCXA21W 03-02-07 11:02:30 EST EAGLE 35.0.0*C 0100.0287 *C LNP 1115 DCM RTDB Table Level 2 FAK Cap Exceeded TABLE: TN Threshold Value: 95% Exceeds 88320000 of 96000000
Alarm Level: Critical
Recovery
1. Enter the following command to verify the database threshold:
rtrv-th-alm
If the threshold is below 95% go to 2.
2. Enter the following command:
chg-th-alm:lnptndblv2=xxxx
UAMs
3-76 EAGLE Unsolicited Alarm and Information Messages Reference
where xxxx=percentage.
3. If the threshold is at 95% contact the My Oracle Support (MOS).
0288 - RTDB Table Level 1 FAK Cap exceeded
This UAM warns the customer that the total TNs in the LNP database has reached80% of the LNP database Feature Access Key (FAK) capacity.
Example
RLGHNCXA21W 03-02-07 11:02:30 ESTEAGLE 35.0.0 ** 0100.0288 ** LNP 1115 DCM RTDB Table Level 1 FAK Cap Exceeded TABLE: TN Threshold Value: 80% Exceeds 76800000 of 96000000
Alarm Level: Major
Recovery
1. Enter the following command to verify the database threshold:
rtrv-th-alm
If the threshold is below 80% go to 2.
2. Enter the following command:
chg-th-alm:lnptndblv2=xxxx
where xxxx=percentage.
3. If the threshold is at 80% contact the My Oracle Support (MOS).
0291 - GLS is at minimum service limit
Only one TSM configured for generic loader services (GLS) is in service. When thismodule fails, GLS is unavailable.
Generic loader services (GLS) are used to download gateway screening data to theLIMs. GLS consists of TSM cards configured with GLS software. They are onlyneeded when LIMs or TSMs must be reloaded.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0291 ** GLS SYSTEM GLS is at minimum service limit
Alarm Level: Major
Recovery
1. Use the rept-stat-card command to verify status of the TSM cards providingGLS.
This command identifies the cards still IS-NR (In-Service – Normal) and thosecards which are out of service. For example, enter:
rept-stat-card
2. Use the init-card command to reinitialize the card and force gateway screening(GWS) data to be downloaded from the active MASP to the TSM.
UAMs
UAM and UIM Troubleshooting Procedures 3-77
3. After GWS data has been successfully downloaded, use rept-stat-card toverify the card(s) have returned to service.
4. If the card(s) do not return to IS-NR, then reseat the card(s).
5. If the card(s) still do not return to IS-NR, replace the card(s).
Refer to the Maintenance Manual, Appendix A, Card Removal/Replacement Procedures.
0292 - GLS is not available
Generic loading services (GLS) is not able to function; the EAGLE 5 ISS may not beperforming gateway screening (GWS).
At least one card should be returned to IS-NR status. This makes GLS available andchanges the alarm level to major (0291 - GLS is at minimum service limit). The alarmclears after two TSM cards have returned to IS-NR.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0*C 0100 0292 *C GLS SYSTEM GLS is not available
Alarm Level: Critical
Recovery
1. Use the rept-stat-card command to verify status of the TSM cards providingGLS.
For example, enter:
rept-stat-card
Example of the output:
RLGHNCXA03W 00-09-27 16:43:42 EST EAGLE 31.3.0CARD VERSION TYPE APPL PST SST AST1113 022-000-000 MCAP OAM IS-NR Active -----1114 ----------- TDM -------- ----- ----- -----1115 022-000-000 MCAP OAM IS-NR Standby -----1116 ----------- TDM -------- ----- ----- -----1117 ----------- MDAL -------- IS-NR Standby -----1204 022-000-000 LIMOCU SS7ANSI OOS-MT Isolated -----1205 022-000-000 LIMOCU SS7ANSI IS-NR Active -----1206 022-000-000 LIMOCU SS7ANSI OOS-MT Isolated -----1212 022-000-000 ACMENET STPLAN IS-NR Active -----1216 022-000-000 TSM SCCP IS-ANR Standby -----1218 022-000-000 TSM GLS OOS-MT Isolated -----1312 022-000-000 LIMDS0 SS7ANSI IS-NR Active -----1313 022-000-000 LIMOCU SS7ANSI OOS-MT Idle -----Command Completed.
2. Use the init-card command to reinitialize the card and force gateway screening(GWS) data to be downloaded from the active MASP to the TSM.
3. The following message should appear.
RLGHNCXA03W 00-02-07 11:11:28 EST EAGLE 35.0.0Init Card command issued to card 1218
UAMs
3-78 EAGLE Unsolicited Alarm and Information Messages Reference
4. After GWS data has been successfully downloaded, use rept-stat-card toverify the card(s) have returned to service.
5. If the card(s) do not return to IS-NR, then reseat the card(s).
6. If the card(s) still do not return to IS-NR, replace the card(s).
Refer to the Maintenance Manual,Appendix A, Card Removal/Replacement Procedures.
0297 - Incorrect port configuration
This message indicates that a MPL card with more than ports A and B provisioned hasbeen replaced with a 2 port DS0-A LIM card. This alarm is also generated if an MPLcard is placed in a LIM slot which has either port A or port B provisioned as non-56Kbps link speed.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0297 ** CARD 1108 SS7ML Incorrect LIM port configuration HW VERIFICATION CODE: xxx
Alarm Level: Major
Recovery
1. If this message contains the optional line ‘HWVERIFICATIONCODE: xxx’:
• Decode the xxx value and correct the indicated problem.
See Hardware Verification Codes in UAMsthe section on hardware verificationcodes in the Unsolicited Alarms and Information Messages manual.
• After correcting the problem, the card will be in out-of-service maintenancedisabled state (OOS-MT-DSBLD).
Restore the card back to in-service normal state (IS-NR) with the alw-cardcommand.
2. If this message does not contain the optional line ‘HWVERIFICATIONCODE: xxx’,perform either of the following:
• Replace the LIMDS0-A card with an MPL card.
OR
• This card has only 2 ports.
Re-provision this DS0-A card and provision only ports A and B. Refer to theDatabase Administration Manual - SS7 to fix the incorrect port configuration.
0300 - TVG Grant Failure
This message indicates that for some card in the system, the grant mechanism (as partof the Multicast Capacity Feature) failed for at least 60 seconds, or more than one timefor a 15-second period. A TVG granter failure is defined as a TVG request thatcompletes with a time-out (hardware or software) and/or a status value where theGranter Present bit is not set.
Example
UAMs
UAM and UIM Troubleshooting Procedures 3-79
RLGHNCXA21W 09-04-06 11:55:14 EST EAGLE5 40.3.0-62.15.21** 0016.0300 ** CARD 1203 SS7ML TVG Grant Failure INFO: SCCP --N---;
An alternate output may be displayed when more than one service is denied.
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 6054.0300 ** CARD 3106 IPLHC TVG Grant Failure INFO: +SLAN --N---;
where the "+" sign (INFO: +SLAN --N---) indicates more than one service.
Alarm Level: Major
Recovery
1. Enter the following command to verify the status of the TVG granter:
rept-stat-card:loc=xxxx:mode=full
wherexxxx is the card location identified in the output.
Example of the output:
tekelecstp 08-09-25 12:06:24 IST EST EAGLE 39.2.0 CARD VERSION TYPE GPL PST SST AST 1204 131-016-000 LIME1 SS7HC IS-NR Active ----- ALARM STATUS = No Alarms. IMTPCI GPL version = 131-007-000 BLVXW6 GPL version = 131-009-000 BLDIAG6 GPL version = 131-008-000 BLBEPM GPL version = 128-021-000 PLDPMC1 GPL version = 128-021-000 BLCPLD GPL version = 128-021-000 IMT BUS A = Conn IMT BUS B = Conn CLOCK A = Active CLOCK B = Fault CLOCK I = Idle HS CLOCK A = Fault HS CLOCK B = Fault HS CLOCK I = Idle MBD BIP STATUS = Valid MOTHER BOARD ID = EPM A DBD STATUS = Valid DBD TYPE = E1T1 DBD MEMORY SIZE = 512M HW VERIFICATION CODE = ---- CARD WARNING = OBSOLETE FRAMER CURRENT TEMPERATURE = 36C ( 97F) PEAK TEMPERATURE: = 37C ( 99F) [04-01-05 11:33] SIGNALING LINK STATUS SLK PST LS CLLI A OOS-MT-DSBLD lsb ----------- TVG STATUS SNM TVG RESULT = 24 hr: ------, 5 min: ------ SLAN TVG RESULT = 24 hr: ------, 5 min: ------ SCCP TVG RESULT = 24 hr: ------, 5 min: ------ INM TVG RESULT = 24 hr: ------, 5 min: ------
UAMs
3-80 EAGLE Unsolicited Alarm and Information Messages Reference
Command Completed.;
2. The group ticket voucher status is displayed in these fields:
SCCP TVG RESULT (for SCCP messages)SLAN TVG RESULT (for STPLAN messages)INM TVG RESULT (for INM messages)SNM TVG RESULT (for SNM messages)
Note: SNM represents network management messages received by theEAGLE (for example, TFP). INM represents network management eventsinternal event processing.
Group ticket voucher status output is displayed as a series of these letters:
GService Granted. Indicates normal system behavior.
DService Denied. Indicates an overload, but the group ticket voucher hardware andsoftware are working correctly.
NNo granter in the system. For GTT or STPLAN traffic, there may be no TSM-SCCP cards or ACMs in the system. If there are TSM-SCCP cards or ACMs in thesystem, then a serious failure is indicated (hardware or software bug or hardwarefailure)
HHardware time-out. Indicates the hardware timed out waiting for a group ticketvoucher packet to return. Group ticket voucher packets can be lost when a card isplugged in or booted. This is a serious condition if cards have not been connectingor disconnecting from the IMT.
SSoftware time-out. No result was ever returned from hardware, indicating aprobable hardware failure.
IInvalid result from hardware.
0308 - Node isolated due to SLK failures
The EAGLE 5 ISS is isolated from other signaling points. All system links are down.Possible causes are as follows:
• Primary and secondary clock sources have failed.
• Signaling links have been manually cancelled.
• All cards have been manually inhibited.
• Both IMT busses have failed.
Example
UAMs
UAM and UIM Troubleshooting Procedures 3-81
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0*C 0100.0308 *C SYSTEM Node isolated due to SLK failures
Alarm Level: Critical
Recovery
1. Contact the My Oracle Support (MOS).
2. Restore the signaling links to service by entering the following:
act-slk:loc=xx:port=x
The following message should appear:
RLGHNCXA03W 00-02-07 11:11:28 EST EAGLE 35.0.0Activate SLK message sent to card
3. Enter the following to restore the cards:
rst-card:loc=xxxx
Note: The card locations (xxxx) must be specified and the command repeatedfor each card.
Automatic recovery of the SLKs should occur.
4. Activate measurements using the chg-meas:collect=on command.
This starts measurements collection.
Note: Refer to the Measurements Manual for traffic measurements information.
0313 - DPC is prohibited
Traffic to the DPC is prohibited. Possible causes:
• All routes to this DPC are unavailable.
• Adjacent point code link failures or nonadjacent failure in the route.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 ** 0044.0313 *C DPCN24 001-001-001 DPC is prohibited LSN=lsn012345 Prohibited SS 5, 20
Legend
ALLOWED SSAllowed subsystem
BLOCKED SSBlocked subsystem
UAMs
3-82 EAGLE Unsolicited Alarm and Information Messages Reference
LSNLinkset name. The name must be unique.
PROHIBITED SSProhibited subsystem
UNBLOCKED SSUnblocked subsystem
Alarm Level: Critical
Recovery
1. Enter the rept-stat-rte command using the DPC specified from the outputmessage to determine which linkset has a problem.
2. Enter the rept-stat-ls using the linkset name specified from the output of Step1 to determine which link(s) could have a problem.
3. Use local procedures to test the link facilities.
0318 - REPT-LKSTO: Link set prohibited
This message indicates a linkset is out of service.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0** 0014.0318 ** LSN a54646 REPT-LKSTO: Link set prohibited
Alarm Level: Major
Recovery
1. Verify the link status using the rept-stat-slk command.
For example, enter:
rept-stat-slk:loc=1203:port=b
Example of the output:
RLGHNCX A03W 00-02-07 12:02:36 EST EAGLE 35.0.0 SLK LSN CLLI PST SST AST 1203,B nsp1 ls02clli OOS-MT Unavail ---- ALARM STATUS = No alarm UNAVAIL REASON = FL NA LI RI Command Completed.
2. Check the UNAVAIL REASON field in the output of the rept-stat-slkcommand.
Following is an explanation of the UNAVAIL REASON codes:
FC – The signaling link is unavailable because of false congestion.
FL – The signaling link has a fault.
NA – The signaling link is not aligned.
UAMs
UAM and UIM Troubleshooting Procedures 3-83
LI – The signaling link has been inhibited locallyRI – The signaling link has beeninhibited remotely.
LB – The signaling link has been blocked locally.
RB – The signaling link has been blocked remotely.
RD(xx.xxx) – The signaling link is unavailable because of a restart delay to preventsignaling link oscillation. The number in parentheses indicates the amount of time,in seconds, remaining in the restart delay period. The link is restarted automaticallyafter this amount of time has elapsed.
3. If the UNAVAIL REASON indicates an alignment problem or fault, activate aloopback using the act-lpb command, or use a physical loopback.
(For a V.35, you must use an appropriate physical V.35 loopback.) If the signalinglink aligns, contact the far-end to correct the problem.
4. If the UNAVAIL REASON still indicates an alignment problem or fault, check thestatus of the card by entering the rept-stat-card command for the specifiedcard.
5. If the rept-stat-card command indicates a problem with the card, reset thecard by entering the init-card command with the specified card location.
If the card still does not align, try first reseating the card, then replacing the card.Refer to the Maintenance Manual,Appendix A, Card Removal/Replacement Procedures.
6. If the UNAVAIL REASON indicates a locally inhibited link, enter the unhb-slkcommand with the specified card location.
7. If the UNAVAIL REASON indicates a locally blocked link, enter the ublk-slkcommand with the specified card location.
8. If the signaling is blocked or inhibited remotely, contact the far-end to place the linkin-service.
0319 - REPT-MTPLP-DET: Circ rte det(cong)
The system automatically tests for circular routing when congestion occurs on anANSI signaling link. If the routing data was provisioned incorrectly, or was corrupted,MSUs could be routed in an endless circular route. The incorrect routing data could beon the system or at a remote STP. This message indicates that circular routing hasbeen detected.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890*C 0044.0319 *C RTXN24 001-101-001 REPT-MTPLP-DET: Circ rte det(cong) OPCA= 007-001-000 XMIT LSN=ls04 RC=20 RCV LSN=lsna05 MEMBER=011-210-004
Alarm Level: Critical
Recovery
UAMs
3-84 EAGLE Unsolicited Alarm and Information Messages Reference
1. Enter the following command to check the routing information for the specifiedDPC:
rtrv-rte
If the problem is in the routing table of an adjacent node, contact the node(identified in the rtrv-rte command output) to resolve the circular routingproblem. If the routing information is correct, continue with 4. If there is an error inthe routing information, continue with 2.
2. Enter the following command to delete the route in the error message from thedatabase:
dlt-rte:aaaa=xxx-xxx-xxx:lsn=yyyy
whereaaa = dpc,dpca,dpci, ordpcn xxx-xxx-xxx = destination point code andyyyy = thelinkset name associated with the route.
3. To enter the correct route information, refer to Database Administration - SS7 User'sGuide for the procedure on adding a route to the SS7 configuration.
4. Enter the following command to reset the destination circular routing status:
rst-dstn:dpc=x-x-x
wherex-x-x = the destination point code of the destination.
0320 - REPT-MTPLP-SUST: Sustained circ rt(cong)
The system automatically tests for circular routing when congestion occurs on anANSI signaling link. If the routing data was provisioned incorrectly, or was corrupted,MSUs could be routed in an endless circular route. The incorrect routing data could beon the system or at a remote STP. This message indicates that circular routing hasbeen detected.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0*C 0014.0320 *C DPC 011-210-* REPT-MTPLP-SUST: Sustained circ rt(cong) XMT LSN=ls01 RC=10 RCV LSN=ls14 MEMBER=011-210-007
Alarm Level: Critical
Recovery
1. Enter the following command to check the routing information for the specifiedDPC:
rtrv-rte
If the problem is in the routing table of an adjacent node, contact the node(identified in the rtrv-rte command output) to resolve the circular routingproblem. If the routing information is correct, continue with 4. If there is an error inthe routing information, continue with 2.
2. Enter the following command to delete the route in the error message from thedatabase:
dlt-rte:aaaa=xxx-xxx-xxx:lsn=yyyy
UAMs
UAM and UIM Troubleshooting Procedures 3-85
where aaa = dpc, dpca, dpci, or dpcn xxx-xxx-xxx = destination point code and yyyy =the linkset name associated with the route.
3. Refer to the "Adding a Route" procedures in Database Administration Manual - SS7 toenter the correct route information.
4. Enter the following command to reset the destination circular routing status:
rst-dstn:dpc=x-x-x
where x-x-x = the destination point code of the destination.
0325 - DPC subsystem is blocked
The DPC subsystem is blocked due to administrative action.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0*C 0014.0325 *C DPC 144-201-001 DPC subsystem is blocked LSN=nc00027 Prohibited SS 1, 5, 18 Allowed SS 3, 6 Blocked SS 100, 103 Unblocked SS 2, 102, 221
Legend
ALLOWED SSAllowed subsystem
BLOCKED SSBlocked subsystem
LSNLinkset name. The name must be unique.
PROHIBITED SSProhibited subsystem
UNBLOCKED SSUnblocked subsystem
Alarm Level: Critical
Recovery
Contact the far-end to correct the problem.
0326 - DPC subsystem is prohibited
The indicated DPC Subsystem is prohibited.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0*C 0014.0326 *C DPC 144-201-001 DPC subsystem is prohibited LSN=nc00027 Prohibited SS 1, 5, 18 Allowed SS 3, 6
UAMs
3-86 EAGLE Unsolicited Alarm and Information Messages Reference
Blocked SS 100, 103 Unblocked SS 2, 102, 221
Legend
ALLOWED SSAllowed subsystem
BLOCKED SSBlocked subsystem
LSNLinkset name. The name must be unique.
PROHIBITED SSProhibited subsystem
UNBLOCKED SSUnblocked subsystem
Alarm Level: Critical
Recovery
Contact the far-end to correct the problem.
0330 - System SCCP TPS Threshold exceeded
This message indicates the Eagle has exceeded its TPS (Transactions Per Second)message transport rate threshold. For every 30 seconds the Eagle is above thethreshold, an ATH (Application Trouble Handler) reports the minimum, maximumand average TPS value seen during the past 30-second period.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0330 ** SCCP SYSTEM System SCCP TPS Threshold exceeded
Alarm Level: Major
Recovery
1. Use rept-stat-sccp to determine the status of the SCCP subsystem.
This command also identifies which SCCP cards are OOS-MT. For example, enter:
rept-stat-sccp
Example of the output:
eaglestp 00-10-24 20:38:58 EST EAGLE 35.0.0 SCCP SUBSYSTEM REPORT IS-NR Ovflw-1 ----- SCCP Cards Configured= 4 Cards IS-NR= 4 System TCP Alarm Threshold = 80% Total capacity System Peak SCCP Load = 3000 TPS System Total SCCP Capacity = 5000 TPS CARD VERSION PST SST AST MSU USAGE CPU USAGE ------------------------------------------------------------------------- 1212 021-001-000 IS-NR ACTIVE ALMINH 47% 32% -------------------------------------------------------------------------
UAMs
UAM and UIM Troubleshooting Procedures 3-87
SCCP Service Average MSU Capacity = 47% Average CPU Capacity = 32% Command Completed.
Use the command rept-stat-sccp:mode=perf to retrieve the maximum andaverage values, if desired.
2. The user may clear this alarm by raising the threshold limit to a value greater thanthe maximum value.
In this case, the alarm stops immediately. You should use the rtrv-th-almcommand to list the threshold rate, and you may use the chg-th-alm commandto change the threshold value.
3. The user should evaluate this new traffic level and determine whether additionalSCCP cards are required to maintain the TPS level the system is processing.
4. Use the rept-stat-card command to display the card status and maintenanceactivity states.
Examine the report for any cards that may be OOS-MT.
5. Use the init-card command to initialize any cards(s) that are OOS-MT.
This causes the card(s) to reload the MTP data as well as GTT data tables.
6. Again using the rept-stat-sccp command, verify the card(s) have returned toservice.
If any card(s) have failed to return to IS-NR, reseat the card(s).
7. If any card(s) remain OOS-MT, replace the card(s).
Refer to the Maintenance manual for card removal/replacement procedures.
0331 - SCCP is not available
The SCCP subsystem is not available to any LIM(s). All TSM/DSM-SCCP cards havefailed.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0*C 0100.0331 *C SCCP SYSTEM SCCP is not available
Alarm Level: Critical
Recovery
1. Use rept-stat-sccp command to determine the status of the SCCP subsystem.
This command also identifies which TSM/DSM cards are OOS-MT. For example,enter:
rept-stat-sccp
Example of the output:
RLGHNCXA03W 00-02-07 16:10:50 EST EAGLE 35.0.0SCCP SUBSYSTEM REPORT IS-NR Active -----SCCP Cards Configured= 1 Cards IS-NR= 1 Capacity Threshold = 100%
UAMs
3-88 EAGLE Unsolicited Alarm and Information Messages Reference
CARD VERSION PST SST AST MSU USAGE CPU USAGE ---------------------------------------------------------------------1212 021-001-000 IS-NR Active ALMINH 47% 32% ---------------------------------------------------------------------SCCP Service Average MSU Capacity = 47% Average CPU Capacity = 32% Command Completed
2. Reinitialize any card(s) not in an IS-NR state using the init-card command.
3. After the card(s) have been reloaded, use the rept-stat-sccp command toverify the SCCP subsystem has returned to full capacity.
4. If any card(s) fail to return to IS-NR, reseat the card(s).
5. If the card(s) still do not return to IS-NR, replace the card(s).
Refer to the Maintenance Manual, Appendix A, Card Removal/Replacement Procedures.
0332 - DPC Subsystem is prohibited and blocked
A subsystem is both prohibited and blocked as reported by the network.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0*C 0014.0332 *C DPC 144-201-001 DPC Subsystem is prohibited and blocked LSN=nc00027 Prohibited SS 1, 5, 18 Allowed SS 3, 6 Blocked SS 100, 103 Unblocked SS 2, 102, 221
Legend
ALLOWED SSAllowed subsystem
BLOCKED SSBlocked subsystem
LSNLinkset name. The name must be unique.
PROHIBITED SSProhibited subsystem
UNBLOCKED SSUnblocked subsystem
Alarm Level: Critical
Recovery
Contact the far-end to test and correct the problem.
0334 - DPC Subsystem is Abnormal
The indicated DPC subsystem is not reachable through the normal route.
Example
UAMs
UAM and UIM Troubleshooting Procedures 3-89
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0*C 0014.0334 *C DPC 144-201-001 DPC Subsystem is Abnormal LSN=nc00027 Prohibited SS 1, 5, 18 Allowed SS 3, 6 Blocked SS 100, 103 Unblocked SS 2, 102, 221
Legend
ALLOWED SSAllowed subsystem
BLOCKED SSBlocked subsystem
LSNLinkset name. The name must be unique.
PROHIBITED SSProhibited subsystem
UNBLOCKED SSUnblocked subsystem
Alarm Level: Critical
Recovery
1. Enter the rept-stat-rte command using the DPC specified from the outputmessage to determine which linkset has a problem.
2. Enter the rept-stat-ls using the linkset name specified from the output of Step1 to determine which link(s) could have a problem.
3. Use local procedures to test the link facilities.
0336 - LIM(s) have been denied SCCP service
Some LIM(s) are using the SCCP subsystem, but others have been denied service. Thisis due to underprovisioning, and will require more Service Module cards to be added.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0* 0100.0336 ** SCCP SYSTEM LIM(s) have been denied SCCP service
Alarm Level: Major
Recovery
1. Use rept-stat-sccp command to determine which LIMs have been deniedSCCP service.
For example, enter:
rept-stat-sccp
Example of the output:
UAMs
3-90 EAGLE Unsolicited Alarm and Information Messages Reference
RLGHNCXA03W 00-02-07 16:10:50 EST EAGLE 35.0.0SCCP SUBSYSTEM REPORT IS-NR Active -----SCCP Cards Configured= 1 Cards IS-NR= 1 Capacity Threshold = 100%CARD VERSION PST SST AST MSU USAGE CPU USAGE ---------------------------------------------------------------------1212 021-001-000 IS-NR Active ALMINH 47% 32% ---------------------------------------------------------------------SCCP Service Average MSU Capacity = 47% Average CPU Capacity = 32% Command Completed
2. Add TSM/DSM-SCCP cards one at a time.
Monitor the performance of the SCCP subsystem with the rept-stat-sccpcommand to determine whether additional cards are needed.
0338 - X-LIST space full-entry(s) discarded
This message indicates that the total number of dynamic status exception list (x-list)entries for cluster routing has exceeded the maximum number configured. No moreentries can be added to the list. This can occur because the maximum number of x-listentries is set too low, the timer that eliminates x-list entries after a specified period isset too long, or the x-list needs to be culled.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0* 0100.0338 ** XLIST X-LIST space full-entry(s) discarded
Alarm Level: Major
Recovery
1. To display the system-wide parameters for cluster routing, enter the rtrv-stpopts command.
Example of the output:
RLGHNCXA03W 00-07-23 16:02:34 EST EAGLE. 31.3.0 STP OPTIONS-------------------------MTPT31CTL 1MTPLT1 yesMTPLTCTDPCQ 3MTPLTST 10000MTPXLQ 500MTPXLET 0100MTPXLOT 90%MTPDPCQ 2000TFATFRPR 1000MTPRSI yesMTPRSIT 5000
The mtpxlq parameter is the total number of dynamic status exception list (x-list)entries the EAGLE 5 ISS maintains. There are 2500 total table entries. The defaultvalues allow for 2000 entries for provisioned destinations and 500 for x-list entries.(If you increase the number of x-list entries, you must decrease the number ofDPCs that can be provisioned by changing the mtpdpcq parameter.) The mtpxletparameter is the maximum amount of time the EAGLE 5 ISS maintains anunreferenced x-list entry.
UAMs
UAM and UIM Troubleshooting Procedures 3-91
2. Use the chg-stpopts to change the number of x-list entries or the x-list expirationtimer.
3. If the problem persists, use the dact-rstst command to eliminate specific x-listentries.
0341 - OAP Unavailable
This message indicates that the EAGLE 5 ISS system is unable to communicate withthe OAP or the OAP has an internal failure.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0341 ** OAP B OAP Unavailable
Alarm Level: Major
Recovery
1. Enter the command to determine the status of the OAP(s):
rept-stat-seas
Example of the output:
RLGHNCXA03W 00-04-17 14:59:11 EST EAGLE 35.0.0 GPL PST SST AST---------------------------------------------------------------------SEAS SYSTEM IS-ANR Restricted -----TDM TRM 6 IS-NR Active -----TDM TRM 9 IS-NR Active -----OAP A 220-001-000 IS-NR Active -----OAP B ----------- OOS-MT Isolated -----X25 Link A1 IS-NR Active -----X25 Link B1 OS-MT Fault -----SEAS SYSTEM ALARM STATUS = ** 0362 LSMS is at min service limitOAP A ALARM STATUS = No Alarms.OAP B ALARM STATUS = ** 0341 OAP unavailableX25 ALARM STATUS = No Alarms.X25 ALARM STATUS = ** 0358 LSMS Q.3 association unavailableX25 A1 PVCs IS-NR = 1,2,3X25 A1 PVCs OOS-MT = ---X25 B1 PVCs IS-NR = ---X25 B1 PVCs OOS-MT = 1,2,3Command Completed.
Refer to the Commands Manual to interpret the output.
Note: If the OAP has an internal failure, yet it can still communicate with thesystem, the state for the OAP appears in the output as OOS-MT/Fault insteadof OOS-MT/Isolated. For instance, if the OAP has a hard disk failure the statewould appear as OOS-MT/Fault. If the hard disk is full, it will notcommunicate.
2. If the OAP has a hard disk failure or the hard disk is full, contact the My OracleSupport (MOS).
UAMs
3-92 EAGLE Unsolicited Alarm and Information Messages Reference
3. If the OAP(s) are out-of-service, check the physical connections.
See the Installation Manual for more information about these system components.
4. Check for any fuse alarms on the Fuse and Alarm Panel in the OAP frame.
There are two 7.5 amp fuses for each OAP. The fuses for OAP1 are marked “Fuse1A” and “Fuse 1B”. The fuses for OAP2 are marked “Fuse 2A” and “Fuse 2B”. Ifthere is a fuse alarm, replace the fuses for the OAP that is unavailable. Also, makesure the two 10 amp breakers are not tripped.
5. Enter the command to verify that the SEAS ports are functioning:
rept-stat-trm
Example of the output:
RLGHNCXA03W 00-02-07 09:50:17 EST EAGLE 35.0.0TRM PST SST AST1 IS-NR Active -----2 IS-NR Active -----3 IS-NR Active -----4 OOS-MT-DSBLD MANUAL -----5 IS-NR Active -----6 IS-NR Active -----7 IS-NR Active -----8 IS-NR Active -----9 IS-NR Active -----10 IS-NR Active -----11 IS-NR Active -----12 IS-NR Active -----13 OOS-MT-DSBLD MANUAL -----14 OOS-MT-DSBLD MANUAL -----15 OOS-MT-DSBLD MANUAL -----16 OOS-MT-DSBLD MANUAL -----Command Completed.
Use the output from 1 (TRM) to identify the OAP ports. Refer to the CommandsManual to interpret the output.
6. If a SEAS port is OOS-MT-DSBLD, enable the port with this command:
rst-trm:trm=x
where x is the OAP port number. If this action corrects the problem, you are donewith this procedure.
7. If the problem persists, verify that the OAP cables are connected to the correctSEASTDM port(s).
8. If the problem persists, verify that the OAP cables are connected to the correct OAPserial ports.
9. Verify the RS-232 parameters are configured properly for the SEAS port byentering the rtrv-trm command for the specified port.
The port should be configured to 19200 baud, even parity, one stop bit, andhardware flow control.
10. If the problem still persists, reset the OAP by entering the init-oap command.
UAMs
UAM and UIM Troubleshooting Procedures 3-93
The OAP comes back in-service within five minutes and the system clears thealarm.
11. If the problem is still not corrected, reseat the TDM card.
If the OAP still does not respond, replace the TDM card. Refer to the MaintenanceManual,Appendix A, Card Removal/Replacement Procedures.
12. If the OAP is still not available, contact the My Oracle Support (MOS).
0342 - SEAS UAL unavailable
This message indicates the SEAS User Application Layer (UAL) process on the OAP isnot running. Layer 4 (UPL) is not available for the specified OAP.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0342 ** SEAS OAP B SEAS UAL unavailable
Alarm Level: Major
Recovery
1. The UAL should recover automatically by restarting.
2. Enter this command to verify the status of the OAP(s):
rept-stat-seas
Example of the output:
RLGHNCXA03W 00-04-17 14:59:11 EST EAGLE 35.0.0 GPL PST SST AST---------------------------------------------------------------------SEAS SYSTEM IS-ANR Restricted -----TDM TRM 6 IS-NR Active -----TDM TRM 9 IS-NR Active -----OAP A 220-001-000 IS-NR Active -----OAP B ----------- OOS-MT Isolated -----X25 Link A1 IS-NR Active -----X25 Link B1 OS-MT Fault -----SEAS SYSTEM ALARM STATUS = ** 0362 LSMS is at min service limitOAP A ALARM STATUS = No Alarms.OAP B ALARM STATUS = ** 0342 SEAS UAL unavailableX25 ALARM STATUS = No Alarms.X25 ALARM STATUS = ** 0358 LSMS Q.3 association unavailableX25 A1 PVCs IS-NR = 1,2,3X25 A1 PVCs OOS-MT = ---X25 B1 PVCs IS-NR = ---X25 B1 PVCs OOS-MT = 1,2,3Command Completed.
Refer to the Commands Manual to interpret the output.
3. If the UAL does not recover, contact the SEAC to test from their equipment to thelocal synchronous modem.
Make sure the X.25 link is activated at their end and the link tests withinspecifications. If possible, have the SEAC or PDN swap X.25 cards at their end witha known good card.
UAMs
3-94 EAGLE Unsolicited Alarm and Information Messages Reference
4. If the problem persists, contact the My Oracle Support (MOS).
0343 - SEAS X.25 Link unavailable
This message indicates the X.25 link to the specified OAP is down. Layer 2 is notavailable for the indicated SEAS X.25 link.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0343 ** X25 Link A1 SEAS X.25 Link unavailable
Alarm Level: Major
Recovery
1. Enter the command to determine the status of the SEAS subsystem:
rept-stat-seas
Example of the output:
RLGHNCXA03W 00-04-17 14:59:11 EST EAGLE 35.0.0 GPL PST SST AST---------------------------------------------------------------------SEAS SYSTEM IS-ANR Restricted -----TDM TRM 6 IS-NR Active -----TDM TRM 9 IS-NR Active -----OAP A 220-001-000 IS-NR Active -----OAP B ----------- OOS-MT Isolated -----X25 Link A1 IS-NR Active -----X25 Link B1 OS-MT Fault -----SEAS SYSTEM ALARM STATUS = ** 0362 LSMS is at min service limitOAP A ALARM STATUS = No Alarms.OAP B ALARM STATUS = ** 0341 OAP unavailableX25 ALARM STATUS = No Alarms.X25 ALARM STATUS = ** 0343 SEAS X.25 Link unavailableX25 A1 PVCs IS-NR = 1,2,3X25 A1 PVCs OOS-MT = ---X25 B1 PVCs IS-NR = ---X25 B1 PVCs OOS-MT = 1,2,3Command Completed.
Refer to the Commands Manual to interpret the output.
2. Check the connections from the synchronous modem (in the OAP frame) to theOAP.
See the Installation Manual for more information about these system components. Ifthe connections are firmly seated, test and if necessary, replace the modem.
3. Determine the status of the X.25 link by entering the following command:
rept-stat-seas
where x is the appropriate TRM number from 1.
Example of the output:
RLGHNCXA03W 00-01-04 15:59:06 EST EAGLE 35.0.0SEAS COMPONENT PST SST AST
UAMs
UAM and UIM Troubleshooting Procedures 3-95
-----------------------------------------------------------SEAS Interface IS_ANR Restricted ------TRM = 2 IS-NR Active ------OAP = A IS-NR Active ------X25 port = A1 IS-NR Active ALMINHPVCs IS-NR = 1, 3PVCs OOS-MT = 2OAP GPL = 022-003-000ALARM STATUS = * 0344 PVC unavailable.Command Completed.
Refer to the Commands Manual to interpret the output.
4. If the problem persists, contact the SEAC to test from their equipment to the localsynchronous modem.
Make sure the X.25 link is activated at their end and the link tests withinspecifications. If possible, have the SEAC or PDN swap X.25 cards at their end witha known good card.
5. If the problem still persists, reset the OAP by entering the init-oap command.
The OAP comes back in-service within three minutes and the system clears thealarm.
6. Determine the status of the X.25 link by entering the command:
rept-stat-seas
where x is the appropriate TRM number from Step 1.
7. If the X.25 link is still unavailable, contact the My Oracle Support (MOS).
0345 - All SEAS UAL sessions unavailable
This message indicates the X.25 User Application Layer (UAL) is not available. If allPVCs for the indicated X.25 link have failed, UAL is no longer available, or all UALsessions are unavailable.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0345 ** SEAS X25 Link B1 All SEAS UAL sessions unavailable
Alarm Level: Major
Recovery
1. Enter this command to determine the status of the OAP(s):
rept-stat-seas
Example of the output:
RLGHNCXA03W 00-04-17 14:59:11 EST EAGLE 35.0.0 GPL PST SST AST---------------------------------------------------------------------SEAS SYSTEM IS-ANR Restricted -----TDM TRM 6 IS-NR Active -----TDM TRM 9 IS-NR Active -----OAP A 220-001-000 IS-NR Active -----
UAMs
3-96 EAGLE Unsolicited Alarm and Information Messages Reference
OAP B ----------- OOS-MT Isolated -----X25 Link A1 IS-NR Active -----X25 Link B1 OS-MT Fault -----SEAS SYSTEM ALARM STATUS = ** 0362 LSMS is at min service limitOAP A ALARM STATUS = No Alarms.OAP B ALARM STATUS = ** 0341 OAP unavailableX25 ALARM STATUS = No Alarms.X25 ALARM STATUS = ** 0345 All SEAS UAL sessions unavailableX25 A1 PVCs IS-NR = 1,2,3X25 A1 PVCs OOS-MT = ---X25 B1 PVCs IS-NR = ---X25 B1 PVCs OOS-MT = 1,2,3Command Completed.
2. Contact the SEAC to verify the X.25 PVCs are correctly configured and activated.
The SEAC should also deactivate and activate the X.25 link.
3. If the problem persists, reset the OAP by entering the init-oap command.
The OAP comes back in-service within three minutes and the system clears thealarm.
4. If the problem persists, contact the SEAC to test from their equipment to the localsynchronous modem.
5. If the X.25 UAL is still not available, contact the My Oracle Support (MOS).
0348 - SEAS is at min service limit
This message indicates that some part of the SEAS subsystem has failed. When thereare two OAPs, this could mean that one OAP has failed, or some part of the path tothe SEAC for that OAP has failed. When there is only one OAP with two X.25 links tothe SEAC and two connections to the TDM serial ports, either one of the X.25 linkshas failed, or one of the serial port connections to the TDM has failed. One morefailure in either case will cause the SEAS subsystem to fail.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0348 ** SEAS SYSTEM SEAS is at min service limit
Alarm Level: Major
Recovery
1. Determine the status of the OAP(s) by entering the following command:
rept-stat-seas
Example of the output:
RLGHNCXA03W 00-04-17 14:59:11 EST EAGLE 35.0.0 GPL PST SST AST---------------------------------------------------------------------SEAS SYSTEM IS-ANR Restricted -----TDM TRM 6 IS-NR Active -----TDM TRM 9 IS-NR Active -----OAP A 220-001-000 IS-NR Active -----OAP B ----------- OOS-MT Isolated -----X25 Link A1 IS-NR Active -----
UAMs
UAM and UIM Troubleshooting Procedures 3-97
X25 Link B1 OS-MT Fault -----SEAS SYSTEM ALARM STATUS = ** 0348 SEAS is at min service limitOAP A ALARM STATUS = No Alarms.OAP B ALARM STATUS = ** 0341 OAP unavailableX25 ALARM STATUS = No Alarms.X25 ALARM STATUS = ** 0358 LSMS Q.3 association unavailableX25 A1 PVCs IS-NR = 1,2,3X25 A1 PVCs OOS-MT = ---X25 B1 PVCs IS-NR = ---X25 B1 PVCs OOS-MT = 1,2,3
Refer to the Commands Manual to interpret the output.
2. If 0341 OAP unavailable is displayed, follow recovery procedure 0341 - OAPUnavailable.
3. If 0343 SEAS X.25
Link unavailable is displayed, follow recovery procedure 0343 - SEAS X.25 Linkunavailable.
4. If 0354 OAP TDM Port unavailable is displayed, follow recovery procedure 0354 - One OAP terminal unavailable.
5. If the OAP(s) are out-of-service check the physical connections.
See the for more information about these system components. If the connections arefirmly seated, test and if necessary, replace the modem.
6. Check for any fuse alarms on the Fuse and Alarm Panel in the OAP frame.
There are two 7.5 amp fuses for each OAP. The fuses for OAP1 are marked “Fuse1A” and “Fuse 1B”. The fuses for OAP2 are marked “Fuse 2A” and “Fuse 2B”. Ifthere is a fuse alarm, replace the fuses for the OAP that is unavailable. Also, makesure the two 10 amp breakers are not tripped.
7. Ensure that the other serial port devices are functioning by entering the followingcommand:
rept-stat-trm
Example of the output:
RLGHNCXA03W 00-02-07 09:50:17 EST EAGLE 35.0.0TRM PST SST AST1 IS-NR Active -----2 IS-NR Active -----3 IS-NR Active -----4 OOS-MT-DSBLD MANUAL -----5 IS-NR Active -----6 IS-NR Active -----7 IS-NR Active -----8 IS-NR Active -----9 IS-NR Active -----10 IS-NR Active -----11 IS-NR Active -----12 IS-NR Active -----13 OOS-MT-DSBLD MANUAL -----14 OOS-MT-DSBLD MANUAL -----15 OOS-MT-DSBLD MANUAL -----
UAMs
3-98 EAGLE Unsolicited Alarm and Information Messages Reference
16 OOS-MT-DSBLD MANUAL -----Command Completed.
Refer to the Commands Manual to interpret the output.
8. Enable the terminal port with the following command:
rst-trm:trm=x
where xis the OAP port number. If this action corrects the problem, you are donewith this procedure.
9. Enter the following command to inhibit the unavailable OAP terminal displayed inthe output from 1:
inh-trm:trm=x
where x is the port number.
Note: The force parameter is required for the last OAP terminal inhibited.
10. If the problem persists, enter the following command to reset the OAP:
init-oap:oap=x
where x is the OAP to be initialized. Verify that the OAP comes back in-servicewithin five minutes and the system clears the alarm. If this clears the alarm,continue with 14.
11. Enter the following command for the inhibited OAP terminal:
chg-trm:trm=x:type=none
where x is the port number.
12. If the problem is still not corrected, reseat the TDM card.
If the OAP still does not respond, replace the TDM card. Refer to the MaintenanceManual,Appendix A, Card Removal/Replacement Procedures.
13. Enter the following command for each OAP terminal inhibited:
chg-trm:trm=x:type=oap
where x is the port number.
14. Enter the command to return the OAP terminals to the in-service state:
alw-trm:trm=x
where x is the port number.
15. If the problem persists, contact the SEAC to test from their equipment to the localsynchronous modem.
16. If the problem is still not corrected, contact the My Oracle Support (MOS).
0349 - SEAS unavailable
This message indicates that the EAGLE 5 ISS system is unable to communicate withthe SEAS subsystem.
UAMs
UAM and UIM Troubleshooting Procedures 3-99
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0*C 0100.0349 *C SEAS SYSTEM SEAS unavailable
Alarm Level: Critical
Recovery
1. Enter the following command to determine the status of the OAP(s):
rept-stat-seas
Following is an example of the output:
RLGHNCXA03W 00-04-17 14:59:11 EST EAGLE 35.0.0 GPL PST SST AST---------------------------------------------------------------------SEAS SYSTEM IS-ANR Restricted -----TDM TRM 6 IS-NR Active -----TDM TRM 9 IS-NR Active -----OAP A 220-001-000 IS-NR Active -----OAP B ----------- OOS-MT Isolated -----X25 Link A1 IS-NR Active -----X25 Link B1 OS-MT Fault -----SEAS SYSTEM ALARM STATUS = *C 0349 SEAS unavailableOAP A ALARM STATUS = No Alarms.OAP B ALARM STATUS = ** 0341 OAP unavailableX25 ALARM STATUS = No Alarms.X25 ALARM STATUS = ** 0358 LSMS Q.3 association unavailableX25 A1 PVCs IS-NR = 1,2,3X25 A1 PVCs OOS-MT = ---X25 B1 PVCs IS-NR = ---X25 B1 PVCs OOS-MT = 1,2,3Command Completed.
Refer to the Commands Manual to interpret the output.
2. If the OAP(s) are out-of-service, check the physical connections.
See the Installation Manual for more information about these system components. Ifthe connections are firmly seated, test and if necessary, replace the modem.
3. If 0341 OAP unavailable is displayed, follow recovery procedure 0341 - OAPUnavailable.
4. If 0342 SEAS UAL unavailable is displayed, follow recovery procedure 0342 -SEAS UAL unavailable.
5. If 0343 SEAS X.25 Link unavailable is displayed, follow recovery procedure 0343 - SEAS X.25 Link unavailable.
6. If 0345 All SEASUAL sessions unavailable is displayed, follow recovery procedure 0345 - All SEAS UAL sessions unavailable.
7. If 0350 OAP terminals inhibited is displayed, follow recovery procedure 0350 - OAP terminals inhibited.
8. Check for any fuse alarms on the Fuse and Alarm Panel in the OAP frame.
UAMs
3-100 EAGLE Unsolicited Alarm and Information Messages Reference
There are two 7.5 amp fuses for each OAP. The fuses for OAP1 are marked “Fuse1A” and “Fuse 1B”. The fuses for OAP2 are marked “Fuse 2A” and “Fuse 2B”. Ifthere is a fuse alarm, replace the fuses for the OAP that is unavailable. Also, makesure the two 10 amp breakers are not tripped.
9. Enter the following command to verify the status of the other serial port devices:
rept-stat-trm
Example of the output:
RLGHNCXA03W 00-02-07 09:50:17 EST EAGLE 35.0.0TRM PST SST AST1 IS-NR Active -----2 IS-NR Active -----3 IS-NR Active -----4 OOS-MT-DSBLD MANUAL -----5 IS-NR Active -----6 IS-NR Active -----7 IS-NR Active -----8 IS-NR Active -----9 IS-NR Active -----10 IS-NR Active -----11 IS-NR Active -----12 IS-NR Active -----13 OOS-MT-DSBLD MANUAL -----14 OOS-MT-DSBLD MANUAL -----15 OOS-MT-DSBLD MANUAL -----16 OOS-MT-DSBLD MANUAL -----Command Completed.
Refer to the Commands Manual to interpret the output.
10. Enable the terminal port with the following command:
rst-trm:trm=x
where x is the serial port number. If this action corrects the problem, you are donewith this procedure.
11. Enter the following command to inhibit the unavailable OAP terminal displayed inthe output from 1:
inh-trm:trm=x
where x is the port number.
Note: The force parameter is required for the last OAP terminal inhibited.
12. If the problem persists, enter this command to reset the OAP:
init-oap:oap=x
where x is the OAP to be initialized. Verify that the OAP comes back in-servicewithin five minutes and the system clears the alarm. If this clears the alarm,continue with 14.
13. Enter the following command for the inhibited OAP terminal:
chg-trm:trm=x:type=none
UAMs
UAM and UIM Troubleshooting Procedures 3-101
where x is the port number.
14. If the problem is still not corrected, reseat the TDM card.
If the OAP still does not respond, replace the TDM card. Refer to the MaintenanceManual,Appendix A, Card Removal/Replacement Procedures.
15. Enter the following command for each OAP terminal inhibited:
chg-trm:trm=x:type=oap
where x is the port number.
16. Enter the following command to return the OAP terminals to the in-service state:
alw-trm:trm=x
where x is the port number.
17. If the problem persists, contact the SEAC to test from their equipment to the localX.25 equipment.
18. If the OAP is still not available, contact the My Oracle Support (MOS).
0350 - OAP terminals inhibited
This message indicates that the OAP terminals are inhibited.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0*C 0100.0350 *C SEAS SYSTEM OAP terminals inhibited
Alarm Level: Critical
Recovery
1. Enter the following command to determine which ports are inhibited:
rept-stat-seas
Following is an example of the output:
RLGHNCXA03W 00-04-17 14:59:11 EST EAGLE 35.0.0 GPL PST SST AST---------------------------------------------------------------------SEAS SYSTEM IS-ANR Restricted -----TDM TRM 6 IS-NR Active -----TDM TRM 9 IS-NR Active -----OAP A 220-001-000 IS-NR Active -----OAP B ----------- OOS-MT Isolated -----X25 Link A1 IS-NR Active -----X25 Link B1 OS-MT Fault -----SEAS SYSTEM ALARM STATUS = *C 0350 OAP terminals inhibitedOAP A ALARM STATUS = No Alarms.OAP B ALARM STATUS = ** 0341 OAP unavailableX25 ALARM STATUS = No Alarms.X25 ALARM STATUS = ** 0358 LSMS Q.3 association unavailableX25 A1 PVCs IS-NR = 1,2,3X25 A1 PVCs OOS-MT = ---X25 B1 PVCs IS-NR = ---
UAMs
3-102 EAGLE Unsolicited Alarm and Information Messages Reference
X25 B1 PVCs OOS-MT = 1,2,3Command Completed.
Refer to the Commands Manual to interpret the output.
2. Enter the following command to verify that the other serial port devices arefunctioning:
rept-stat-trm
Following is an example of the output:
RLGHNCXA03W 00-02-07 09:50:17 EST EAGLE 35.0.0 TRM PST SST AST 1 IS-NR Active ----- 2 IS-NR Active ----- 3 IS-NR Active ALMINH 4 IS-NR Active ----- 5 OOS-MT-DSBLD Manual ----- 6 IS-NR Active ----- 7 IS-NR Active ----- 8 IS-NR Active ----- 9 IS-NR Active ----- 10 IS-NR Active ----- 11 IS-NR Active ALMINH 12 IS-NR Active ----- 13 IS-NR Active ----- 14 IS-NR Active ----- 15 IS-NR Active ----- 16 IS-NR Active ----- Command Completed
Refer to the Commands Manual to interpret the output.
3. If only the SEAS port(s) are not functioning, enable the SEAS port(s) with thefollowing command:
rst-trm:trm=x
where x is the OAP port number. If this action corrects the problem, you are donewith this procedure.
4. Enter the following command to inhibit the unavailable OAP terminal displayed inthe output from 1:
inh-trm:trm=x
where x is the port number.
Note: The force parameter is required for the last OAP terminal inhibited.
5. Enter the following command for the inhibited OAP terminal:
chg-trm:trm=x:type=none
where x is the port number.
6. If the problem is still not corrected, reseat the TDM card.
UAMs
UAM and UIM Troubleshooting Procedures 3-103
If the problem persists, replace the TDM card. Refer to the Maintenance manual forcard removal/replacement procedures.
7. Enter the following command for each OAP terminal inhibited:
chg-trm:trm=x:type=oap
where x is the port number.
8. Enter the following command to return the OAP terminals to the in-service state:
alw-trm:trm=x
where x is the port number.
0354 - One OAP terminal unavailable
This message indicates that the OAP terminal specified in the output message is notavailable.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0354 ** OAP B One OAP terminal unavailable
Alarm Level: Major
Recovery
1. Enter the following command to determine which port is unavailable:
rept-stat-seas
Following is an example of the output:
RLGHNCXA03W 00-04-17 14:59:11 EST EAGLE 35.0.0 GPL PST SST AST---------------------------------------------------------------------SEAS SYSTEM IS-ANR Restricted -----TDM TRM 6 IS-NR Active -----TDM TRM 9 IS-NR Active -----OAP A 220-001-000 IS-NR Active -----OAP B ----------- OOS-MT Isolated -----X25 Link A1 IS-NR Active -----X25 Link B1 OS-MT Fault -----SEAS SYSTEM ALARM STATUS = ** 0362 LSMS is at min service limitOAP A ALARM STATUS = No Alarms.OAP B ALARM STATUS = ** 0354 One OAP terminal unavailableX25 ALARM STATUS = No Alarms.X25 ALARM STATUS = ** 0358 LSMS Q.3 association unavailableX25 A1 PVCs IS-NR = 1,2,3X25 A1 PVCs OOS-MT = ---X25 B1 PVCs IS-NR = ---X25 B1 PVCs OOS-MT = 1,2,3Command Completed.
Refer to the Commands Manual to interpret the output.
2. Enter the following command to verify that the other ports are functioning:
rept-stat-trm
UAMs
3-104 EAGLE Unsolicited Alarm and Information Messages Reference
Following is an example of the output:
RLGHNCXA03W 00-02-07 09:50:17 EST EAGLE 35.0.0TRM PST SST AST1 IS-NR Active -----2 IS-NR Active -----3 IS-NR Active -----4 OOS-MT-DSBLD MANUAL -----5 IS-NR Active -----6 IS-NR Active -----7 IS-NR Active -----8 IS-NR Active -----9 IS-NR Active -----10 IS-NR Active -----11 IS-NR Active -----12 IS-NR Active -----13 OOS-MT-DSBLD MANUAL -----14 OOS-MT-DSBLD MANUAL -----15 OOS-MT-DSBLD MANUAL -----16 OOS-MT-DSBLD MANUAL -----Command Completed.
Refer to the Commands Manual to interpret the output.
3. Enable the terminal port with the following command:
rst-trm:trm=x
where x is the serial port number. If this action corrects the problem, you are donewith this procedure.
4. Check the physical connections between the OAP and the system.
Make sure the connectors are firmly seated. If this action corrects the problem, youare done with this procedure.
5. Enter the following command to inhibit the unavailable OAP terminal displayed inthe output from 1:
inh-trm:trm=x
where x is the port number.
Note: The force parameter is required for the last OAP terminal inhibited.
6. If the problem persists, enter the following command to reset the OAP:
init-oap:oap=x
where x is the OAP to be initialized. Verify that the OAP comes back in-servicewithin five minutes and the system clears the alarm. If this clears the alarm,continue with 10.
7. Enter the following command for the inhibited OAP terminal:
chg-trm:trm=x:type=none
where x is the port number.
8. If the problem is still not corrected, reseat the TDM card.
UAMs
UAM and UIM Troubleshooting Procedures 3-105
If the OAP still does not respond, replace the TDM card. Refer to the Maintenancemanual for card removal/replacement procedures.
9. Enter the following command for each OAP terminal inhibited:
chg-trm:trm=x:type=oap
where x is the port number.
10. Enter the following command to return the OAP terminals to the in-service state:
alw-trm:trm=x
where x is the port number.
11. If the problem is still not corrected, contact the My Oracle Support (MOS).
0356 - LSMS is unavailable
There are no communication paths available to the LSMS. This condition is reachedwhen all OAP terminals are manually inhibited or all LSMS associations are down.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0*C 0014.0356 *C LSMS SYSTEM LSMS is unavailable
Alarm Level: Critical
Recovery
1. Enter the command to verify the status of the terminals:
rept-stat-trm
Example of the output:
RLGHNCXA03W 00-02-07 09:50:17 EST EAGLE 35.0.0TRM PST SST AST1 IS-NR Active -----2 IS-NR Active -----3 IS-NR Active -----4 OOS-MT-DSBLD MANUAL -----5 IS-NR Active -----6 IS-NR Active -----7 IS-NR Active -----8 IS-NR Active -----9 IS-NR Active -----10 IS-NR Active -----11 IS-NR Active -----12 IS-NR Active -----13 OOS-MT-DSBLD MANUAL -----14 OOS-MT-DSBLD MANUAL -----15 OOS-MT-DSBLD MANUAL -----16 OOS-MT-DSBLD MANUAL -----Command Completed.
Refer to the Commands Manual to interpret the output.
2. Enable the terminal port with the following command:
alw-trm:trm=x
UAMs
3-106 EAGLE Unsolicited Alarm and Information Messages Reference
where x is the serial port number. If this action corrects the problem, you are donewith this procedure.
3. Check the physical connections between the OAP and the LSMS.
Make sure the connectors are firmly seated.
4. Check the physical connections between the OAP and the system.
Make sure the connectors are firmly seated.
5. Enter the command to verify the status of the LSMS:
rept-stat-lsms
Sample output:
RLGHNCXA03W 00-04-17 14:59:11 EST Release 31.3.0 GPL PST SST AST---------------------------------------------------------------------LSMS SYSTEM IS-ANR Restricted -----TDM TRM 6 IS-NR Active -----OAP A 220-001-000 OOS-MT Isolated -----OAP B ----------- OOS-MT Isolated -----Q.3 Assoc A1 IS-NR Active -----Q.3 Assoc B1 OS-MT Fault -----LSMS SYSTEM ALARM STATUS = *C 0356 LSMS is unavailableOAP A ALARM STATUS = No Alarms.OAP B ALARM STATUS = ** 0341 OAP unavailableQ.3 Assoc A1 ALARM STATUS = No Alarms.Q.3 Assoc B1 ALARM STATUS = ** 0358 LSMS Q.3 association unavailableCommand Completed.
Refer to the Commands Manual to interpret the output.
6. If the problem still persists, reset the OAP by entering the command:
init-oap:oap=x
where x is a,b, or both. See the Commands Manual for the correct usage. Thisprocedure is complete if the OAP comes back in-service within five minutes andthe system clears the alarm.
7. Enter the command to verify the status of the LSMS:
rept-stat-lsms
Refer to 5 for a sample output.
8. Enter the command to inhibit the unavailable OAP terminal displayed in theoutput from 1:
inh-trm:trm=x
where x is the port number.
Note: The force parameter is required for the last OAP terminal inhibited.
9. Enter the command for the inhibited OAP terminal:
UAMs
UAM and UIM Troubleshooting Procedures 3-107
chg-trm:trm=x:type=none
where x is the port number.
10. If the problem is still not corrected, reseat the TDM card.
If the OAP still does not respond, replace the TDM card. Refer to the Maintenancemanual for card removal/replacement procedures.
11. Enter the command for each OAP terminal inhibited:
chg-trm:trm=x:type=oap
where x is the port number.
12. Enter this command to return the OAP terminals to the in-service state:
alw-trm:trm=x
where x is the port number.
13. Enter the command to verify the status of the LSMS:
rept-stat-lsms
Refer to 5 for a sample output.
14. If the LSMS is still not available, contact the My Oracle Support (MOS).
0358 - LSMS connection unavailable
An LSMS connection is not available.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0** 0014.0358 ** LSMS Q.3 Assoc. A1 LSMS connection unavailable
Alarm Level: Major
Recovery
1. Check the physical connections between the OAP and the LSMS.
Make sure the connectors are firmly seated.
2. Enter the following command to verify the status of the LSMS:
rept-stat-lsms
A sample output follows:
RLGHNCXA03W 00-04-17 14:59:11 EST Release 31.3.0 GPL PST SST AST---------------------------------------------------------------------LSMS SYSTEM IS-ANR Restricted -----TDM TRM 6 IS-NR Active -----OAP A 220-001-000 OOS-MT Isolated -----OAP B ----------- OOS-MT Isolated -----Q.3 Assoc A1 IS-NR Active -----Q.3 Assoc B1 OS-MT Fault -----LSMS SYSTEM ALARM STATUS = ** 0362 LSMS is at min service limitOAP A ALARM STATUS = No Alarms.
UAMs
3-108 EAGLE Unsolicited Alarm and Information Messages Reference
OAP B ALARM STATUS = ** 0341 OAP unavailableQ.3 Assoc A1 ALARM STATUS = No Alarms.Q.3 Assoc B1 ALARM STATUS = ** 0358 LSMS connection unavailableCommand Completed.
Refer to the Commands Manual to interpret the output.
3. If the problem still persists, reset the OAP by entering the following command:
init-oap:oap=x
where x is a,b or both. See the Commands Manual for the correct usage. Thisprocedure is complete if the OAP comes back in-service within three minutes andthe system clears the alarm.
4. Enter the following command to verify the status of the LSMS:
rept-stat-lsms
Refer to 2 for a sample output.
5. Enter the following command to inhibit the unavailable OAP terminal displayed inthe output from 1:
inh-trm:trm=xwhere x is the port number.
Note: The force parameter is required for the last OAP terminal inhibited.
6. Enter the following command for the inhibited OAP terminal:
chg-trm:trm=x:type=none
where x is the port number.
7. If the problem is still not corrected, reseat the TDM card.
If the OAP still does not respond, replace the TDM card. Refer to the Maintenancemanual for card removal/replacement procedures.
8. Enter the following command for each OAP terminal inhibited:
chg-trm:trm=x:type=oap
where x is the port number.
9. Enter the following command to return the OAP terminals to the in-service state:
alw-trm:trm=x
where x is the port number.
10. Enter the following command to verify the status of the LSMS:
rept-stat-lsms
Refer to 2 for a sample output.
11. If the LSMS connection is still not available, contact the My Oracle Support (MOS).
UAMs
UAM and UIM Troubleshooting Procedures 3-109
0360 - EMS Agent unavailable
An EMS agent is not available.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0360 ** OAP B EMS Agent unavailable
Alarm Level: Major
Recovery
1. Reset the OAP by entering the following command:
init-oap:oap=x
where x is a, b, or both. Refer to the Commands Manual for the correct usage. Thisprocedure is complete if the OAP comes back in-service within five minutes andthe system clears the alarm.
2. Enter the following command to determine the reason for the failure: rept-stat-lsms
Following is an example of the output:
RLGHNCXA03W 00-04-17 14:59:11 EST Release 31.3.0 GPL PST SST AST---------------------------------------------------------------------LSMS SYSTEM IS-ANR Restricted -----TDM TRM 6 IS-NR Active -----OAP A 220-001-000 OOS-MT Isolated -----OAP B ----------- OOS-MT Isolated -----Q.3 Assoc A1 IS-NR Active -----Q.3 Assoc B1 OS-MT Fault -----LSMS SYSTEM ALARM STATUS = ** 0362 LSMS is at min service limitOAP A ALARM STATUS = No Alarms.OAP B ALARM STATUS = ** 0360 EMS Agent unavailableQ.3 Assoc A1 ALARM STATUS = No Alarms.Q.3 Assoc B1 ALARM STATUS = ** 0358 LSMS Q.3 association unavailableCommand Completed.
Refer to the Commands Manual to interpret the output.
3. Enter the following command to inhibit the unavailable OAP terminal displayed inthe output from Step 2:
inh-trm:trm=x
where x is the port number.
Note: The force parameter is required for the last OAP terminal inhibited.
4. Enter the following command for the inhibited OAP terminal:
chg-trm:trm=x:type=none
where x is the port number.
UAMs
3-110 EAGLE Unsolicited Alarm and Information Messages Reference
5. If the problem is still not corrected, reseat the TDM card.
If the OAP still does not respond, replace the TDM card. Refer to the Maintenancemanual for card removal/replacement procedures.
6. Enter the following command for each OAP terminal inhibited:
chg-trm:trm=x:type=oap
where x is the port number.
7. Enter the following command to return the OAP terminals to the in-service state:
alw-trm:trm=x
where x is the port number.
8. If the EMS agent is still not available, contact the My Oracle Support (MOS).
0362 - LSMS is at min. service limit
Only one communication path is available to the LSMS.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0** 0014.0362 ** LSMS SYSTEM LSMS is at min. service limit
Alarm Level: Major
Recovery
1. Enter the following command to determine the reason for the failure:
rept-stat-lsms
Following is an example of the output:
GPL PST SST ASTRLGHNCXA03W 00-04-17 14:59:11 EST Release 31.3.0---------------------------------------------------------------------LSMS SYSTEM IS-ANR Restricted -----TDM TRM 6 IS-NR Active -----OAP A 220-001-000 OOS-MT Isolated -----OAP B ----------- OOS-MT Isolated -----Q.3 Assoc A1 IS-NR Active -----Q.3 Assoc B1 OS-MT Fault -----LSMS SYSTEM ALARM STATUS = ** 0362 LSMS is at min service limitOAP A ALARM STATUS = No Alarms.OAP B ALARM STATUS = ** 0341 OAP unavailableQ.3 Assoc A1 ALARM STATUS = No Alarms.Q.3 Assoc B1 ALARM STATUS = ** 0358 LSMS Q.3 association unavailableCommand Completed.
Refer to the Commands Manual to interpret the output.
2. If 0341 OAP unavailable is displayed, follow recovery procedure 0341 - OAPUnavailable.
3. If 0358 LSMS Q.3 association unavailable is displayed, follow recoveryprocedure 0358 - LSMS connection unavailable.
UAMs
UAM and UIM Troubleshooting Procedures 3-111
4. If 0354 OAP TDM Port unavailable is displayed, follow recovery procedure 0354 - One OAP terminal unavailable.
5. If the problem is not solved, contact the My Oracle Support (MOS).
0367 - Temp Key(s) expiring soon
This alarm indicates that one or more temporary keys used to enable a controlledfeature will expire within the next seven days.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 5.0.0-32.0.0** 0100.0367 SYSTEM Temp Key(s) expiring soon
Alarm Level: Major
Recovery
1. Enter the following command to retrieve information about controlled features:rtrv-ctrl-feat:enable=temp
The output of the rtrv-ctrl-feat:enable=temp command displaysinformation about the number of days left for temporarily enabled features.
Following is an example of the output:
The following features have been temporarily enabled:RLGHNCXA03W 99-01-07 00:57:31 EST EAGLE 5.0.0-32.0.0Feature Name Partnum Status Quantity Trial Period LeftTPS 893000140 on 4000 6 days 5 hrs 3 mins
2. If you do nothing within the remaining trial period, the critical alarm, “0368 - TempKey(s) have expired” will display when the trial period expires.
3. If you wish to acquire this feature permanently, you can purchase it from Tekelec.
The alarm will be cleared when the purchased feature is enabled using theenable-ctrl-feat command.
0368 - Temp Key(s) have expired
This alarm indicates that one or more temporary keys used to enable a controlledfeature have expired.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 5.0.0-32.0.0*C 0100.0368 SYSTEM Temp Key(s) have expired
Alarm Level: Critical
Recovery
1. Enter the following command to retrieve information about controlled features:rtrv-ctrl-feat:expired=yes
The output of the rtrv-ctrl-feat:expired=yes command displaysinformation about expired temporarily enabled features.
Following is an example of the output:
UAMs
3-112 EAGLE Unsolicited Alarm and Information Messages Reference
RLGHNCXA03W 99-01-07 00:57:31 EST EAGLE 5.0.0-32.0.0The following features have expired temporary keys:Feature Name Part NumTPS 8930000140
2. You can enter the chg-ctrl-feat:partnum=893xxxxxx:alarm=clearcommand to clear this alarm.
3. If you wish to acquire this feature permanently, you can purchase it from Tekelecand enable it using the enable-ctrl-feat command.
The alarm will clear when the purchased feature is installed with a permanent key.
0369 - REPT-T1F:FAC-T1 unavailable
There is a problem at the far end and the far end is not communicating with theEAGLE 5 ISS.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0369 ** T1/J1PORT 1201,2 REPT-T1F:FAC-T1 unavailable
Alarm Level: Major
Recovery
1. Contact the far-end office to determine the cause and to correct the problem.
0370 - Critical Platform Failure(s)
This message indicates the application running in the MPS server has detected acritical platform failure. The Alarm Data in the message contains a 16-characterhexadecimal string in the format of h’1xxxxxxxxxxxxxxx’. This alarm will be resetwhen UAM #250, MPS Available is issued.
Example
station1234 00-09-30 16:28:08 EST EAGLE 35.0.0*C 0259.0370 *C MPS B Critical Platform Failure(s) ALARM DATA = h'1000000000000008'
Alarm Level: Critical
Recovery
1. To decode the ALARMDATA included in this alarm, write down the Alarm Datastring.
2. To decode the alarm and for the correct procedure to solve the problem, refer to theMPS Platform Software and Maintenance Manual.
3. This alarm will be reset when the problem is resolved and you receive UIM #250MPS Available.
0371 - Critical Application Failure(s)
This message indicates the application running in the MPS server has detected acritical application failure. The Alarm Data in the message contains a 16-character
UAMs
UAM and UIM Troubleshooting Procedures 3-113
hexadecimal string in the format of h’2xxxxxxxxxxxxxxx’. This alarm will be resetwhen UAM #250, MPS Available is issued.
Example
station1234 00-09-30 16:28:08 EST EAGLE 35.0.0*C 0259.0371 *C MPS B Critical Application Failure(s) ALARM DATA = h'2000000000000001'
Alarm Level: Critical
Recovery
1. To decode the ALARMDATA included in this alarm, write down the Alarm Datastring.
2. To decode the alarm and for the correct procedure to solve the problem, refer to theMPS Platform Software and Maintenance Manual.
3. This alarm will be reset when the problem is resolved and you receive UIM #250MPS Available.
0372 - Major Platform Failure(s)
This message indicates the application running in the MPS server has detected a majorplatform failure. The Alarm Data in the message contains a 16-character hexadecimalstring in the format of h’3xxxxxxxxxxxxxxx’. This alarm will be reset when UAM #250,MPS Available is issued.
Example
station1234 00-09-30 16:28:08 EST EAGLE 35.0.0** 0259.0372 ** MPS B Major Platform Failure(s) ALARM DATA = h'3000000000000002'
Alarm Level: Major
Recovery
1. To decode the ALARMDATA included in this alarm, write down the Alarm Datastring.
2. To decode the alarm and for the correct procedure to solve the problem, refer to theMPS Platform Software and Maintenance Manual.
3. This alarm will be reset when the problem is resolved and you receive UIM #250MPS Available.
0373 - Major Application Failure(s)
This message indicates the application running in the MPS server has detected a majorapplication failure. The Alarm Data in the message contains a 16-characterhexadecimal string in the format of h’4xxxxxxxxxxxxxxx’. This alarm will be resetwhen UAM #250, MPS Available is issued.
Example
station1234 00-09-30 16:28:08 EST EAGLE 35.0.0** 0259.0373 ** MPS B Major Application Failure(s) ALARM DATA = h'4000000000000008'
Alarm Level: Major
UAMs
3-114 EAGLE Unsolicited Alarm and Information Messages Reference
Recovery
1. To decode the ALARMDATA included in this alarm, write down the Alarm Datastring.
2. To decode the alarm and for the correct procedure to solve the problem, refer to theMPS Platform Software and Maintenance Manual.
3. This alarm will be reset when the problem is resolved and you receive UIM #250MPS Available.
0376 - REPT-T1F:FAC-T1 LOS failure
No signal is being received on the T1 Port.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0376 ** T1PORT 1201,2 REPT-T1F:FAC-T1 LOS failure
Alarm Level: Major
Recovery
Check the physical connections.
0377 - REPT-T1F:FAC-T1 LOF failure
The 7-bit frame alignment signal does not match the pattern the EAGLE 5 ISS isexpecting.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0377 ** T1PORT 1201,2 REPT-T1F:FAC-T1 LOF failure
Alarm Level: Major
Recovery
Contact the far-end office to correct their framing problem.
0378 - REPT-T1F:FAC-T1 Remote Alarm
This indicates there is some type of failure on the far end.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0378 ** T1PORT 1201,2 REPT-T1F:FAC-T1 Remote Alarm
Alarm Level: Major
Recovery
Contact the far-end office to determine the cause and correct the problem.
0379 - REPT-T1F:FAC-T1 Alarm
The far end is transmitting an alarm indication signal (AIS) due to an excessive biterror rate, loss of signal, or loss of frame.
Example
UAMs
UAM and UIM Troubleshooting Procedures 3-115
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0377 ** T1PORT 1201,2 REPT-T1F:FAC-T1 Alarm
Alarm Level: Major
Recovery
Contact the far-end office to determine the cause of the AIS and to correct theproblem.
0381 - REPT-E1F:FAC-E1 LOS failure
No signal is being received on the signaling link.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0381 ** E1PORT 1201,2 REPT-E1F:FAC-E1 LOS failure
Alarm Level: Major
Recovery
Check the physical connections.
0382 - REPT-E1F:FAC-E1 LOF failure
The 7-bit frame alignment signal does not match the pattern the EAGLE 5 ISS isexpecting.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0382 ** E1PORT 1201,2 REPT-E1F:FAC-E1 LOF failure
Alarm Level: Major
Recovery
Contact the far-end office to correct their framing problem.
0383 - REPT-E1F:FAC-E1 AIS detected
The far end is transmitting an alarm indication signal (AIS) due to an excessive biterror rate, loss of signal, or loss of frame.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0383 ** E1PORT 1201,2 REPT-E1F:FAC-E1 AIS detected
Alarm Level: Major
Recovery
Contact the far-end office to determine the cause of the AIS and to correct theproblem.
0384 - REPT-E1F:FAC-E1 Far End Failure
This indicates there is some type of failure on the far end.
Example
UAMs
3-116 EAGLE Unsolicited Alarm and Information Messages Reference
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0384 ** E1PORT 1201,2 REPT-E1F:FAC-E1 Far End Failure
Alarm Level: Major
Recovery
Contact the far-end office to determine the cause and to correct the problem.
0385 - REPT-E1F:FAC-E1 10E-3 BER failed
A framing bit error rate is maintained for in-service links because the error rate is high.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0385 ** E1PORT 1201,2 REPT-E1F:FAC-E1 10E-3 BER failed
Alarm Level: Major
Recovery
Contact the far-end office to determine the cause of the high framing bit error rate.
0387- REPT-E1F:FAC-E1 unavailable
There is a problem at the far end and the far end is not communicating with theEAGLE 5 ISS.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0387 ** E1PORT 1201,2 REPT-E1F:FAC-E1 unavailable
Alarm Level: Major
Recovery
Contact the far-end office to determine the cause and to correct the problem.
0389 - Card Responding Normally
This message indicates the clearing of a prior card problem.
Example
0014.0389 CARD 1201 Card Responding Normally
Alarm Level: No alarm condition. The message is informational only.
Recovery
No further action is necessary.
0390 - Illegal Address Error
This message indicates an HMUX (High Speed Multiplexer) illegal address error. TheATH (Application Trouble Handler) displays this alarm when an HMUX-assignedshelf ID address, which was received from OAM and written to the Assigned ShelfAddress Register, did not match the value read from the Assigned Shelf AddressRegister. Furthermore, the error was not corrected after an automatic attempt tocorrect the address discrepancy.
UAMs
UAM and UIM Troubleshooting Procedures 3-117
Example
station1234 00-11-30 16:28:08 EST EAGLE 35.0.0** 0012.0390 ** CARD 1109 HMUX Illegal Address Error
Alarm Level: Major
Recovery
1. Reset the HMUX card in question by entering the command:
init-mux:loc=xy09 (or loc=xy10)
This command resets the card, but it does not take down the IMT bus on which thecard resides; operation of the bus is unaffected by this command.
2. If the problem persists, then you should reseat the HMUX card in question.
Remember that this action will take down the IMT bus of the HMUX card.
3. If the problem remains, the card must be replaced.
Contact the My Oracle Support (MOS).
0391 - Card not responding Error
This message indicates an HMUX (High Speed Multiplexer)/HIPR (High-Speed IMTPacket Router) is not responding. This alarm is displayed when an HMUX/HIPR in aprovisioned shelf card does not respond.
Example
station1234 00-11-30 16:28:08 EST EAGLE 35.0.0** 0012.0391 ** CARD 1109 HIPR Card not responding Error
Alarm Level: Major
Recovery
1. Reset the HMUX/HIPR card in question by entering the command:
init-mux:loc=xy09 (or loc=xy10)
This command resets the card, but it does not take down the IMT bus on which thecard resides; operation of the bus is unaffected by this command.
2. If the problem persists, then you should reseat the HMUX/HIPR card in question.
Remember that this action will take down the IMT bus of the HMUX/HIPR card.
3. If the problem remains, the card must be replaced.
Contact the My Oracle Support (MOS).
0392 - OA&M IP Security feature is OFF
The Eagle OA&M IP Security Enhancements Feature is not turned on. One of thefollowing occurred: and OAM init, or OAM role change, or the chg-ctrl-featcommand turned the feature off.
With this feature not operating, you do not have the tools to securely pass data acrossan otherwise non-secure network. Until the Eagle OA&M IP Security EnhancementsFeature is restored, the Eagle cannot provide secure connections from approved
UAMs
3-118 EAGLE Unsolicited Alarm and Information Messages Reference
clients, and does not protect sensitive passwords and information while in transitbetween the Eagle and a host.
Example
eagle11 17-12-07 09:23:41 EST EAGLE 46.5.0.0.0-0.0.0 2001.0392 SECURITY SYSTEM OA&M IP Security feature status is OFF;
Alarm Level: Major
Recovery
To restore the OA&M IP Security Enhancements feature, you turn it on permanently.
To turn the feature on, use the command.
enable-ctrl-feat
0395 - INP Subsystem is not available
The INP subsystem is not available. There are no IS-NRVSCCP cards associated withthis INP subsystem. The INP subsystem was not taken off-line via command.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 39.2.0*C 0056.0395 *C INP SYSTEM INP Subsystem is not available
Alarm Level: Critical
Recovery
1. Enter the following command to verify the status and location of the subsystemcards:
rept-stat-mps
2. Enter the following command to move the VSCCP cards to an ACTIVE status ifloading is successful:
rst-card:loc=xxxx
where xxxx is the location of the OOS-MT-DSBLDVSCCP card(s) identified in 1.
3. Enter the following command to verify the status and location of the subsystemcards:
rept-stat-mps
4. Verify the VSCCP card(s) reset in 2 are IS-NR.
If not, reseat the card(s).
5. If any card(s) remain OOS-MT, replace the card(s).
Refer to the Maintenance manual for card removal/replacement procedures.
0396 - INP Subsystem is disabled
The INP subsystem has been manually disabled using the inh-map-ss command.
Example
UAMs
UAM and UIM Troubleshooting Procedures 3-119
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 39.2.0*C 0056.0396 *C INP SYSTEM INP Subsystem is disabled
Alarm Level: Critical
Recovery
1. Enter this command to verify the status and location of the INP subsystem cards:
rept-stat-mps
2. Enter this command to to reserve the subsystem number and to change the state ofthe INP subsystem status to on-line:
ent-ss-appl:appl=inp:ssn=xx:stat=online
where xx is primary subsystem number.
3. Enter this command to change the state of the INP subsystem to on-line:
alw-map-ss:ssn=xx
where xx is primary subsystem number.
4. Enter this command to verify the status of the INP subsystem:
rept-stat-mps
0403 - 1114 E1/T1 clock requires TDM-GTI
This message indicates that the high speed clock is provisioned as T1 framed, E1framed, or E1 unframed. A non TDM-GTI card has been placed in this system whererecovered clocks are provisioned. The TDM-GTI version of the TDM card is required.
Example
station1234 99-03-05 16:28:08 EST EAGLE 35.0.0 ** 0052.0403 ** HS CLOCK SYSTEM 1114 E1/T1 clock requires TDM-GTI
Alarm Level: Major
Recovery
Perform one of the following:
• Replace the card in location 1114 with a TDM-GTI card. Refer to the Maintenancemanual for card removal/replacement procedures for the replacement procedure.
OR
• Use the chg-clkoptschg-stpopts command to change the hsclksrc parameterto RS422. Refer to the Commands Manual for proper usage of the command.
0404 - 1116 E1/T1 clock requires TDM-GTI
This message indicates that the high speed clock is provisioned as T1 framed, E1framed, or E1 unframed. A non TDM-GTI card has been placed in this system whererecovered clocks are provisioned. The TDM-GTI version of the TDM card is required.
Example
UAMs
3-120 EAGLE Unsolicited Alarm and Information Messages Reference
station1234 99-03-05 16:28:08 EST EAGLE 35.0.0** 0052.0404 ** HS CLOCK SYSTEM 1116 E1/T1 clock requires TDM-GTI
Alarm Level: Major
Recovery
Perform one of the following:
• Replace the card in location 1116 with a TDM-GTI card. Refer to the Maintenancemanual for card removal/replacement procedures for the replacement procedure.
OR
• Use the chg-clkoptschg-stpopts command to change the HSCLKSRCparameter to RS422. Refer to the Commands Manual for proper usage of thecommand.
0405 - 1114, 1116 E1/T1 clock requires TDM-GTI
This message indicates that the high speed clock is provisioned as T1 framed, E1framed, or E1 unframed. A non TDM-GTI card has been placed in this system in slots1114 and 1116 where recovered clocks are provisioned. The TDM-GTI version of theTDM card is required.
Example
station1234 99-03-05 16:28:08 EST EAGLE 35.0.0** 0052.0405 ** HS CLOCK SYSTEM 1114, 1116 E1/T1 clock requires TDM-GTI
Alarm Level: Major
Recovery
Perform one of the following:
• Replace the cards in locations 1114 and 1116 with a TDM-GTI card. Refer to theMaintenance manual for card removal/replacement procedures for thereplacement procedure.
OR
• Use the chg-clkoptschg-stpopts command to change the HSCLKSRCparameter to RS422. Refer to the Commands Manual for proper usage of thecommand.
0406 - 1114 Clock selection mismatch
This message indicates that the database has been restored and the provisioned clocksdo not match what is running on the TDM.
Example
station1234 99-03-05 16:28:08 EST EAGLE 31.6.0 ** 0052.0406 ** HS CLOCK SYSTEM 1114 Clock selection mismatch
Alarm Level: Major
Recovery
1. Enter the following command to determine the current clock settings on the TDM:
UAMs
UAM and UIM Troubleshooting Procedures 3-121
rept-stat-clk
Following is an example of the output:
rept-stat-clk Command entered at terminal #3.; tekelecstp 99-03-05 13:34:15 EST EAGLE 31.6.0 CARD LOC= 1114 (Active ) CARD LOC= 1116 (Isolated ) PRIMARY BITS = Active PRIMARY BITS = ----- SECONDARY BITS = Idle SECONDARY BITS = ----- HS PRIMARY CLK = Active HS PRIMARY CLK = ----- HS SECONDARY CLK = Idle HS SECONDARY CLK = ----- HS CLK TYPE = E1 UNFRAMED HS CLK TYPE = ----- HS CLK LINELEN = SHORTHAUL HS CLK LINELEN = ----- PST SST AST SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using CLK A = 009 # Cards with bad CLK A = 000 # Cards using CLK B = 000 # Cards with bad CLK B = 009 # Cards using CLK I = 000 PST SST AST HS SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using HSCLK A = 001 # Cards with bad HSCLK A = 000 # Cards using HSCLK B = 000 # Cards with bad HSCLK B = 002 # Cards using HSCLK I = 000 Command Completed.
2. Use the chg-clkoptschg-stpopts command to update the database to matchthe output displayed when you issued the previous command.
Refer to the Commands Manual for proper usage of the command.
0407 - 1116 Clock selection mismatch
This message indicates that the database has been restored and the provisioned clocksdo not match what is running on the TDM.
Example
station1234 99-03-05 16:28:08 EST EAGLE 31.6.0 ** 0052.0407 ** HS CLOCK SYSTEM 1116 Clock selection mismatch
Alarm Level: Major
Recovery
1. Enter the following command to determine the current clock settings on the TDM:
rept-stat-clk
Following is an example of the output:
rept-stat-clk Command entered at terminal #3.; tekelecstp 99-03-05 13:34:15 EST EAGLE 31.6.0 CARD LOC= 1114 (Active ) CARD LOC= 1116 (Isolated ) PRIMARY BITS = Active PRIMARY BITS = -----
UAMs
3-122 EAGLE Unsolicited Alarm and Information Messages Reference
SECONDARY BITS = Idle SECONDARY BITS = ----- HS PRIMARY CLK = Active HS PRIMARY CLK = ----- HS SECONDARY CLK = Idle HS SECONDARY CLK = ----- HS CLK TYPE = E1 UNFRAMED HS CLK TYPE = ----- HS CLK LINELEN = SHORTHAUL HS CLK LINELEN = ----- PST SST AST SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using CLK A = 009 # Cards with bad CLK A = 000 # Cards using CLK B = 000 # Cards with bad CLK B = 009 # Cards using CLK I = 000 PST SST AST HS SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using HSCLK A = 001 # Cards with bad HSCLK A = 000 # Cards using HSCLK B = 000 # Cards with bad HSCLK B = 002 # Cards using HSCLK I = 000 Command Completed.
2. Use the chg-clkoptschg-stpopts command to update the database to matchthe output displayed when you issued the previous command.
Refer to the Commands Manual for proper usage of the command.
0408 - 1114, 1116 Clock selection mismatch
This message indicates that the database has been restored and the provisioned clocksdo not match what is running on the TDM.
Example
station1234 99-03-05 16:28:08 EST EAGLE 31.6.0 ** 0052.0408 ** HS CLOCK SYSTEM 1114, 1116 Clock selection mismatch
Alarm Level: Major
Recovery
1. Enter the following command to determine the current clock settings on the TDM:
rept-stat-clk
Following is an example of the output:
rept-stat-clk Command entered at terminal #3.; tekelecstp 99-03-05 13:34:15 EST EAGLE 31.6.0 CARD LOC= 1114 (Active ) CARD LOC= 1116 (Isolated ) PRIMARY BITS = Active PRIMARY BITS = ----- SECONDARY BITS = Idle SECONDARY BITS = ----- HS PRIMARY CLK = Active HS PRIMARY CLK = ----- HS SECONDARY CLK = Idle HS SECONDARY CLK = ----- HS CLK TYPE = E1 UNFRAMED HS CLK TYPE = ----- HS CLK LINELEN = SHORTHAUL HS CLK LINELEN = ----- PST SST AST SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using CLK A = 009 # Cards with bad CLK A = 000 # Cards using CLK B = 000 # Cards with bad CLK B = 009 # Cards using CLK I = 000
UAMs
UAM and UIM Troubleshooting Procedures 3-123
PST SST AST HS SYSTEM CLOCK IS-NR ACTIVE ALMINH ALARM STATUS = No Alarms. # Cards using HSCLK A = 001 # Cards with bad HSCLK A = 000 # Cards using HSCLK B = 000 # Cards with bad HSCLK B = 002 # Cards using HSCLK I = 000 Command Completed.
2. Use the chg-clkoptschg-stpopts command to update the database to matchthe output displayed when you issued the previous command.
Refer to the Commands Manual for proper usage of the command.
0422 - Insufficient extended memory
At least one SCCP card does not have enough memory for the LNP application.Loading of the SCCP card is automatically inhibited.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0422 ** CARD 1113 SCCP Insufficient extended memory HW VERIFICATION CODE: xxx
Alarm Level: Major
Recovery
1. If this message contains the optional line ‘HWVERIFICATIONCODE: xxx’:
a. Decode the xxx value and correct the indicated problem.
See Hardware Verification Codes in UAMsthe section on hardware verificationcodes in the Unsolicited Alarms and Information Messages manual.
b. After correcting the problem, the card will be in out-of-service maintenancedisabled state (OOS-MT-DSBLD).
Restore the card back to in-service normal state (IS-NR) with the alw-cardcommand. If this message does not contain the optional line‘HWVERIFICATIONCODE: xxx’, continue with the next step.
2. Verify the SCCP hardware.
Verify the SCCP cards have at least 256M of memory.
3. If necessary, replace the SCCP card with the correct combination of motherboardand daughterboard.
Refer to the Maintenance manual for card removal/replacement procedures.
0424 - LNP Subsystem is not available
The LNP subsystem is not available. There are no IS-NRSCCP cards associated withthis LNP subsystem. The LNP subsystem was not taken off-line via command.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0*C 0056.0424 *C LNP SYSTEM LNP Subsystem is not available
UAMs
3-124 EAGLE Unsolicited Alarm and Information Messages Reference
Alarm Level: Critical
Recovery
1. Enter the following command to verify the status and location of the subsystemcards:
rept-stat-lnp
2. Enter the following command to move the SCCP cards to an ACTIVE status ifloading is successful:
rst-card:loc=xxxx
where xxxx is the location of the OOS-MT-DSBLD SCCP card(s) identified in 1.
3. Enter the following command to verify the status and location of the subsystemcards:
rept-stat-lnp
4. Verify the SCCP card(s) reset in 2 are IS-NR.
If not, reseat the card(s).
5. If any card(s) remain OOS-MT, replace the card(s).
Refer to the Maintenance manual for card removal/replacement procedures.
0427 - LNP Subsystem degraded, card(s) abnormal
One or more LNP cards goes out of service in (N or N+1) configuration or not IS-NR.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 46.0.0** 0056.0427 ** LNP SYSTEM LNP Subsystem degraded, card(s) abnormal
Alarm Level: Major.
Recovery
1. Restore the one or more LNP out of service cards in (N or N+1) configuration ornot IS-NR.
0428 - INP Subsystem degraded, card(s) abnormal
One or more INP cards goes out of service in (N or N+1) configuration or not IS-NR.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 46.0.00056.0428 INP SYSTEM INP Subsystem degraded, card(s) abnormal
Alarm Level: Major.
Recovery
1. Restore the one or more INP out of service cards in (N or N+1) configuration or notIS-NR.
UAMs
UAM and UIM Troubleshooting Procedures 3-125
0429 - ATINPQ Subsystem degraded, card(s) abnormal
One or more ATINPQ cards goes out of service in (N or N+1) configuration or not IS-NR.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 46.0.00056.0429 ATINPQ SYSTEM ATINPQ Subsystem degraded, card(s) abnormal
Alarm Level: Major.
Recovery
1. Restore the one or more ATINPQ out of service cards in (N or N+1) configurationor not IS-NR.
0435 - LNP Subsystem is disabled
The LNP subsystem has been manually disabled using the inh-map-ss command.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.0*C 0056.0435 *C LNP SYSTEM LNP Subsystem is disabled
Alarm Level: Critical
Recovery
1. Enter the following command to verify the status and location of the LNPsubsystem cards:
rept-stat-lnp
2. Enter the following command to change the state of the LNP subsystem status toon-line:
ent-ss-appl:appl=lnp:ssn=xx:stat=online
where xx is primary subsystem number.
3. Enter the following command to change the state of the LNP subsystem to on-line:
alw-map-ss:ssn=xx
where xx is primary subsystem number.
4. Enter the following command to verify the status of the LNP subsystem:
rept-stat-lnp
0436 - LNP ACG node overload
This message indicates that the number of LNP subsystem queries has exceeded thesupported level.
Example
station1234 94-03-30 16:28:08 EST EAGLE 35.0.0** 0056.0436 ** LNP SYSTEM LNP ACG node overload
UAMs
3-126 EAGLE Unsolicited Alarm and Information Messages Reference
Alarm Level: Major
Recovery
1. Enter the following command to verify the status, quantity, and capacity of theSCCP cards:
rept-stat-lnp
2. Refer to the ELAP Administration and LNP Feature Activation to verify thatprovisioning rules are being followed.
3. If the problem persists, contact the My Oracle Support (MOS).
0437 - System SCCP TPS Capacity Exceeded
This message indicates the Eagle has exceeded its TPS (Transactions Per Second)message transport rate. The alarm will not stop until the TPS rate is below its ratedTPS for the system for a period of 30 seconds. The alarm is cleared by the UIM #329“SCCP capacity normal, card(s) abnormal”.
Example
RLGHNCXA21W 00-11-07 11:02:30 EST EAGLE 35.0.0*C 0100.0437 *C SYSTEM System SCCP TPS Capacity Exceeded
Alarm Level: Critical
Recovery
1. Use rept-stat-sccp to determine the status of the SCCP subsystem.
This command also identifies which SCCP cards are OOS-MT. For example, enter:
rept-stat-sccp
Example of the output:
eaglestp 00-10-24 20:38:58 EST EAGLE 35.0.0 SCCP SUBSYSTEM REPORT IS-NR Ovflw-1 ----- SCCP Cards Configured= 4 Cards IS-NR= 4 System TCP Alarm Threshold = 80% Total capacity System Peak SCCP Load = 3000 TPS System Total SCCP Capacity = 5000 TPS CARD VERSION PST SST AST MSU USAGE CPU USAGE ------------------------------------------------------------------------- 1212 021-001-000 IS-NR ACTIVE ALMINH 47% 32% ------------------------------------------------------------------------- SCCP Service Average MSU Capacity = 47% Average CPU Capacity = 32% Command Completed.
2. The user should evaluate this new traffic level and determine whether additionalSCCP cards are required to maintain the TPS level the system is processing.
0438 - Degraded Mode, Invalid OAM HW config
This UAM alarm occurs when the system does not have the required baselinehardware. Baseline hardware required includes TDM-10 or greater. The alarm recursevery minute. Also, the act_upgrade command is rejected if alarm is present.
UAMs
UAM and UIM Troubleshooting Procedures 3-127
Example
RLGHNCXA21W 02-12-07 12:01:43 EST EAGLE 35.0.0 *C 0014.0438 *C SECULOG 1114 Degraded Mode, Invalid OAM HW config
Alarm Level: Critical
Recovery
Ensure that the Eagle has the required hardware baseline, that is, the TDM-10 orgreater is installed.
0441 - Incorrect MBD - CPU
A card (TSM/DSM) does not have the required hardware configuration for theapplication, or a TSM is attempting to load in a slot provisioned for SCCP GPLs.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0441 ** CARD 1108 VSCCP Incorrect MBD - CPU HW VERIFICATION CODE: xxx
Alarm Level: Major
Recovery
1. If this message contains the optional line ‘HWVERIFICATIONCODE: xxx’:
• Decode the xxx value and correct the indicated problem.
See Hardware Verification Codes in UAMsthe section on hardware verificationcodes in the Unsolicited Alarms and Information Messages manual.
• After correcting the problem, the card will be in out-of-service maintenancedisabled state (OOS-MT-DSBLD).
Restore the card back to in-service normal state (IS-NR) with the alw-cardcommand.
If this message does not contain the optional line ‘HWVERIFICATIONCODE:xxx’, continue with the next step.
2. Verify the hardware.
Verify the card(s) (TSM/DSM) have the correct motherboard/daughterboardcombination.
3. If necessary, replace the card(s) (TSM/DSM) card with the correct combination ofmotherboard and daughterboard.
Refer to the Maintenance manual for card removal/replacement procedures.
0442 - RTDB database capacity is 90% full
EPAP database capacity alarms are triggered by allocated capacity, whereas EAGLEalarms are triggered by provisioned capacity.
Allocated Capacity refers to the amount of memory that is currently dedicated tostoring each RTDB entity-type. For instance when the very first DN is added to theEPAP RTDB, the EPAP allocates a block of memory large enough to store 6 millionDNs. Although most of this memory is not in-use (provisioned) it has been
UAMs
3-128 EAGLE Unsolicited Alarm and Information Messages Reference
demarcated for future use and cannot be utilized to store other non-DN entities (suchas IMSIs or DN-Blocks, etc).
Provisioned Capacity refers to the provisioned RTDB entries versus the max RTDBentries allowed on an EAGLE SM card by the EPAP/ELAP related quantity featuresactivated on EAGLE. EAGLE RTDB capacity alarms are triggered when theprovisioned capacity passes the 80% and 90% levels. Furthermore, if the EAGLE RTDBprovisioned capacity is below 80% and the allocation of the next memory block byEPAP would cause overallocation of the DSM Memory on an EPAP SM card, theEAGLE will report the 80% capacity alarm for that card.
Example
RLGHNCXA21W 14-05-07 11:02:30 EST EAGLE 46.0.00100.0442 *C CARD 1108 VSCCP RTDB database capacity is 90% full
Alarm Level:Critical
Recovery
1. For ELAP, perform the following:
a. Use the rept-stat-sccp command to identify all SCCP cards.
tekelecstp 000623 13:34:22 EST EAGLE5 36.0.0 SCCP SUBSYSTEM REPORT IS-NR Active SCCP ALARM STATUS = No Alarms INPQ SUBSYSTEM REPORT IS-ANR Restricted ----- ASSUMING MATE’S LOAD INPQ: SSN STATUS = Allowed MATE SSN STATUS = Prohibited INPQ ALARM STATUS = No Alarms GFLEX SERVICE REPORT IS-ANR Active GFLEX ALARM STATUS = No Alarms MNP SERVICE REPORT IS-ANR Active MNP ALARM STATUS = No Alarms
SCCP Cards Configured=4 Cards IS-NR=2 System TPS Alarm Threshold = 100% Total Capacity System Peak SCCP Load = 3000 TPS System Total SCCP Capacity = 5000 TPS
CARD VERSION PST SST AST MSU USAGE CPU USAGE -------------------------- 1212 101-001-000 IS-NR Active ALMINH 45% 30% 1301 P 101-001-000 IS-NR Active ------ 35% 40% 1305 ----------- OOS-MT Isolated ------ 0% 0% 2112 ----------- OOS-MT-DSBLD Manual ------ 0% 0% --------------------------- SCCP Service Average MSU Capacity = 40% Average CPU Capacity = 35%
AVERAGE CPU USAGE PER SERVICE: GTT = 15% GFLEX = 5% MNP = 10% INPMR = 2% INPQ = 3%
TOTAL SERVICE STATISTICS: FAIL REROUTE\ FORWARD
UAMs
UAM and UIM Troubleshooting Procedures 3-129
SERVICE SUCCESS ERRORS RATIO WARNINGS TO GTT TOTAL GTT: 1995 5 0% - - 2000 GFLEX: 500 1 0% 4 10 515 MNP: 800 0 0% 2 3 805 INPMR: 50 5 0% 0 15 70 INPQ: 499 1 0% - - 500
Command Completed.;
b. Use the rept-stat-card:loc=xxxx:mode=full command to determinedaughterboard memory on each SCCP card.
wherexxxx is the SCCP card location. Verify the DSM’s database memory size.
rlghncxa03w 05-07-27 16:43:42 EST EAGLE 30.0.0CARD VERSION TYPE APPL PST SST AST1113 023-102-000 GPSM EOAM IS-NR Active ----- ALARM STATUS = No Alarms. BPDCM GPL version = 023-001-000 IMT BUS A = Conn IMT BUS B = Conn CLOCK A = Active CLOCK B = Idle CLOCK I = Idle MBD BIP STATUS = valid DB STATUS = valid DBD MEMORY SIZE = 256M TROUBLE TEXT VER. = Rev 1.6Command Completed.;
c. Use the rtrv-ctrl-feat command to verify the LNP Database featurequantity purchased for this system.
d. Refer to ELAP Administration and LNP Feature Activation Guide to view the DSMrequirements for the LNP telephone number quantity verified under rtrv-ctrl-feat. Contact your Oracle Communications Sales Representative orAccount Representative if larger DSMs are needed.
Proceed to next step if DSM capacity is not the issue.
e. From the ELAP GUI, execute View RTDB Status and verify the ELAP isreporting the same alarm as the EAGLE.
f. Verify the TN Counts listed on the GUI.
g. Go to View LNP Qty Features on the ELAP GUI and verify the LNP ported TNs.This value should reflect the same information as seen under rtrv-ctrl-feat in theEAGLE.
h. If the TN Count under View RTDB Status is 90% of the LNP ported TNs shownunder View LNP Qty Features, this is the cause of the UAM 0442 – RTDBdatabase capacity is 90% full.
UAMs
3-130 EAGLE Unsolicited Alarm and Information Messages Reference
i. If the TN Count is not 90% of the LNP ported TNs, check to see if the NPANXXor LRN Counts are 90% of the LNP ported NPANXXs or LRNs values.
j. Reduce the number of either TNs, LRNs, or NPANXXs by utilizing features/tools on the LSMS. Refer to Database Administrator's Guide for LSMS.
k. If reducing the number of TNs, LRNs, or NPANXXs is not a viable option,increase the LNP telephone number quantity. Refer to the section "Activatingthe LNP Feature on the EAGLE" in Administration and LNP Feature ActivationGuide for ELAP. Contact My Oracle Support (MOS) if you do not currently havethe next higher TN quantity key.
2. For EPAP, perform the following:
a. Use the rtrv-stpopts command to determine the status of EPAP dataquantity related options. The following example shows the status of theEPAP240M Feature:
Command Accepted - Processing tekelecstp 16-03-16 12:05:53 MST EAGLE5 46.3.0.0.0-68.14.0 STP OPTIONS ------------------------------- EPAP240M off;
b. Use the rtrv-ctrl-feat:status=on command to determine the status ofEPAP data related features that are currently activated. The following exampleshows the status of the EPAP Data Split feature:
rlghncxa03w 12-03-13 16:40:40 EST EAGLE 46.4.0The following features have been permanently enabled:
Feature Name Partnum Status Quantity
EPAP Data Split 893039801 on ----Dual ExAP Config 893040501 on ----;
c. Run the rtrv-bip:loc=<> command and use the part number of the card todetermine the hardware type:
Command Accepted - Processing
eagle1 16-10-03 18:31:34 EST EAGLE 46.3.0.0.1-68.27.0 rtrv-bip:loc=1317 Command entered at terminal #13.;
eagle1 16-10-03 18:31:34 EST EAGLE 46.3.0.0.1-68.27.0 -------------------------------------------------------------------------- Location: 1317 - MBD
Part Number: 870-2990-01 Revision: F Week/Year: 14/2012 Serial Number: 10212145089
Software Match ID: EG - 001 Max Power Rating : 1537mA --------------------------------------------------------------------------
UAMs
UAM and UIM Troubleshooting Procedures 3-131
END OF REPORT;
See the "Hardware Baseline EAGLE Release 45.0 - 46.x" table in HardwareReference for card part numbers.
d. Run the rept-stat-card:mode=full:loc=<> command and use the GPLname to determine the GPL type (32-bit or 64-bit) the card is running.
See Chapter 3, "Introduction" in Database Administration - System Management todetermine the GPL types.
Command Accepted - Processing
eagle1 16-10-03 18:18:12 EST EAGLE 46.3.0.0.1-68.27.0 rept-stat-card:mode=full:loc=1317 Command entered at terminal #13.;
eagle1 16-10-03 18:18:12 EST EAGLE 46.3.0.0.1-68.27.0 CARD VERSION TYPE GPL PST SST AST 1317 138-022-000 DSM SCCP64 IS-NR Active ----- ALARM STATUS = No Alarms. BLDC64 GPL version = 138-023-000 IMT BUS A = Conn IMT BUS B = Disc CLOCK A = Active CLOCK B = Fault CLOCK I = Idle MBD BIP STATUS = Valid MOTHER BOARD ID = SMXG B DBD STATUS = Valid DBD TYPE = None DBD MEMORY SIZE = 8192M HW VERIFICATION CODE = ---- CURRENT TEMPERATURE = 28C ( 83F) PEAK TEMPERATURE: = 32C ( 90F) [16-09-21 02:02] SCCP % OCCUP = 0% SCCP SM DATA TYPE = DN APPLICATION SERVICING MFC MFC SNM REQ STATUS = 24 hr: ---, 5 min: --- INM REQ STATUS = 24 hr: ---, 5 min: --- MTP3 REQ STATUS = 24 hr: ---, 5 min: --- SFLOG REQ STATUS = 24 hr: ---, 5 min: --- IPLNK STATUS IPLNK IPADDR STATUS PST A 192.168.120.13 UP IS-NR B 192.168.121.13 UP IS-NR DSM IP CONNECTION PORT PST SST A IS-NR Active B IS-NR Active
Command Completed.;
e. Refer to the "EAGLE Feature and EPAP DB Capacity Combinations" table inDatabase Administration - GTT User's Guide to determine the maximum RTDB
UAMs
3-132 EAGLE Unsolicited Alarm and Information Messages Reference
capacity based on the installed hardware and EPAP Quantity features activatedin the system.
f. Do one of the following:
• Reduce the size of the database to match the installed hardware capacities.
• Obtain and install a larger capacity SM card.
• Obtain and activate the appropriate EPAP Quantity features.
• Verify that the SM card is running the appropriate GPL type (32-bit or 64-bit).
g. If the SM card requires 64-bit GPLs and the card is currently running 32-bitGPLs, see "Conversion of SM8G-B Cards" or "Conversion of SLIC Cards" inDatabase Administration - System Management User's Guide to convert 32-bit GPLsto 64-bit.
0443 - RTDB database corrupted
A RTDB database is corrupt. The calculated checksum did not match the checksumvalue stored for one or more records.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0* 0100.0443 * CARD 1108 VSCCP RTDB database corrupted
Alarm Level:Minor
Recovery
1. Enter the following command to verify the status of the RTDB database:
rept-stat-db:display=all:db=mps
Caution: If more than one card is corrupt, perform 2 through 5 to completionfor one card at a time.
2. Enter the following command to verify the status of the corrupt card:
rept-stat-card:loc=xxxx
Where xxxx is the location of the card identified in the output.
3. Examine the output from 2 Verify that the SST (secondary state of the card) is notRestrict.
If the SST is Restrict, do not continue with this procedure. Contact the MyOracle Support (MOS).
4. Enter the following command to correct the VSCCP card.
This command reinitializes the card and forces the card to load the current level ofthe database. Wait for the reload to complete before continuing.
init-card:loc=xxxx
Where xxxx is the location of the card identified in output.
UAMs
UAM and UIM Troubleshooting Procedures 3-133
5. Enter the following command to verify that the database is the same level as theother cards in the system:
rept-stat-db:display=all:db=mps
6. If the problem persists, contact the My Oracle Support (MOS).
0446 - RTDB database capacity is 80% full
EPAP database capacity alarms are triggered by allocated capacity, whereas EAGLEalarms are triggered by provisioned capacity.
Allocated Capacity refers to the amount of memory that is currently dedicated tostoring each RTDB entity-type. For instance when the very first DN is added to theEPAP RTDB, the EPAP allocates a block of memory large enough to store 6 millionDNs. Although most of this memory is not in-use (provisioned) it has beendemarcated for future use and cannot be utilized to store other non-DN entities (suchas IMSIs or DN-Blocks, etc.).
Provisioned Capacity refers to the provisioned RTDB entries versus the max RTDBentries allowed on an EAGLE SM card by the EPAP/ELAP related quantity featuresactivated on EAGLE. EAGLE RTDB capacity alarms are triggered when theprovisioned capacity passes the 80% and 90% levels. Furthermore, if the EAGLE RTDBprovisioned capacity is below 80% and the allocation of the next memory block byEPAP would cause overallocation of the DSM Memory on an EPAP SM card, theEAGLE will report the 80% capacity alarm for that card.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0.0* 0100.0446 * CARD 1108 VSCCP RTDB database capacity is 80% full
Alarm Level: Minor
Recovery
1. For ELAP, perform the following from the EAGLE STP:
a. Use the rept-stat-sccp command to identify all SCCP cards.
tekelecstp 000623 13:34:22 EST EAGLE5 36.0.0 SCCP SUBSYSTEM REPORT IS-NR Active SCCP ALARM STATUS = No Alarms INPQ SUBSYSTEM REPORT IS-ANR Restricted ----- ASSUMING MATE’S LOAD INPQ: SSN STATUS = Allowed MATE SSN STATUS = Prohibited INPQ ALARM STATUS = No Alarms GFLEX SERVICE REPORT IS-ANR Active GFLEX ALARM STATUS = No Alarms MNP SERVICE REPORT IS-ANR Active MNP ALARM STATUS = No Alarms
SCCP Cards Configured=4 Cards IS-NR=2 System TPS Alarm Threshold = 100% Total Capacity System Peak SCCP Load = 3000 TPS System Total SCCP Capacity = 5000 TPS
CARD VERSION PST SST AST MSU USAGE CPU USAGE -------------------------- 1212 101-001-000 IS-NR Active ALMINH 45%
UAMs
3-134 EAGLE Unsolicited Alarm and Information Messages Reference
30% 1301 P 101-001-000 IS-NR Active ------ 35% 40% 1305 ----------- OOS-MT Isolated ------ 0% 0% 2112 ----------- OOS-MT-DSBLD Manual ------ 0% 0% --------------------------- SCCP Service Average MSU Capacity = 40% Average CPU Capacity = 35%
AVERAGE CPU USAGE PER SERVICE: GTT = 15% GFLEX = 5% MNP = 10% INPMR = 2% INPQ = 3%
TOTAL SERVICE STATISTICS: FAIL REROUTE\ FORWARD SERVICE SUCCESS ERRORS RATIO WARNINGS TO GTT TOTAL GTT: 1995 5 0% - - 2000 GFLEX: 500 1 0% 4 10 515 MNP: 800 0 0% 2 3 805 INPMR: 50 5 0% 0 15 70 INPQ: 499 1 0% - - 500
Command Completed.;
b. Use the rept-stat-card:loc=xxxx:mode=full command to determinedaughterboard memory for each SCCP card.
where xxxx is the SCCP card location.
rlghncxa03w 05-07-27 16:43:42 EST EAGLE 30.0.0CARD VERSION TYPE APPL PST SST AST1113 023-102-000 GPSM EOAM IS-NR Active ----- ALARM STATUS = No Alarms. BPDCM GPL version = 023-001-000 IMT BUS A = Conn IMT BUS B = Conn CLOCK A = Active CLOCK B = Idle CLOCK I = Idle MBD BIP STATUS = valid DB STATUS = valid DBD MEMORY SIZE = 256M TROUBLE TEXT VER. = Rev 1.6Command Completed.;
c. Use the rtrv-ctrl-feat command to verify the LNP Database featurequantity purchased for this system.
d. Refer to ELAP Administration and LNP Feature Activation to view the DSMrequirements for the LNP telephone number quantity verified under rtrv-ctrl-
UAMs
UAM and UIM Troubleshooting Procedures 3-135
feat. Contact your Sales Representative or Account Representative if largerDSMs are needed.
Proceed to next step if DSM capacity is not the issue.
e. From the ELAP GUI, execute View RTDB Status and verify the ELAP isreporting the same alarm as the EAGLE.
f. Verify the TN Counts listed on the GUI.
g. Go to View LNP Qty Features on the ELAP GUI and verify the LNP portedTNs. This value should reflect the same information as seen under rtrv-ctrl-feat in the EAGLE.
h. If the TN Count under View RTDB Status is 80% of the LNP ported TNsshown under View LNP Qty Features, this is the cause of the UAM 0446 –RTDB database capacity is 80% full.
i. If the TN Count is not 80% of the LNP ported TNs, check to see if the NPANXXor LRN Counts are 80% of the LNP ported NPANXXs or LRNs values.
j. Reduce the number of either TNs, LRNs, or NPANXXs by utilizing features/tools on the LSMS. Refer to Database Administration Guide for LSMS.
k. If reducing the number of TNs, LRNs, or NPANXXs is not a viable option,increase the LNP telephone number quantity. Refer to the section Activating theLNP Feature on the EAGLE in ELAP Administration and LNP Feature Activation.
Contact My Oracle Support (MOS), if you do not currently have the next higherTN quantity key.
2. For EPAP, perform the following:
a. Use the rtrv-stpopts command to determine the status of EPAP dataquantity related options. The following example shows the status of theEPAP240M Feature:
Command Accepted - Processing tekelecstp 16-03-16 12:05:53 MST EAGLE5 46.3.0.0.0-68.14.0 STP OPTIONS ------------------------------- EPAP240M off;
b. Use the rtrv-ctrl-feat:status=on command to determine the status ofEPAP data related features that are currently activated. The following exampleshows the status of the EPAP Data Split feature:
rlghncxa03w 12-03-13 16:40:40 EST EAGLE 46.4.0The following features have been permanently enabled:
Feature Name Partnum Status Quantity
EPAP Data Split 893039801 on ----Dual ExAP Config 893040501 on ----;
c. Run the rtrv-bip:loc=<> command and use the part number of the card todetermine the hardware type:
UAMs
3-136 EAGLE Unsolicited Alarm and Information Messages Reference
Command Accepted - Processing
eagle1 16-10-03 18:31:34 EST EAGLE 46.3.0.0.1-68.27.0 rtrv-bip:loc=1317 Command entered at terminal #13.;
eagle1 16-10-03 18:31:34 EST EAGLE 46.3.0.0.1-68.27.0 -------------------------------------------------------------------------- Location: 1317 - MBD
Part Number: 870-2990-01 Revision: F Week/Year: 14/2012 Serial Number: 10212145089
Software Match ID: EG - 001 Max Power Rating : 1537mA -------------------------------------------------------------------------- END OF REPORT;
See the "Hardware Baseline EAGLE Release 45.0 - 46.x" table in HardwareReference for card part numbers.
d. Run the rept-stat-card:mode=full:loc=<> command and use the GPLname to determine the GPL type (32-bit or 64-bit) the card is running.
See Chapter 3, "Introduction" in Database Administration - System Management todetermine the GPL types.
Command Accepted - Processing
eagle1 16-10-03 18:18:12 EST EAGLE 46.3.0.0.1-68.27.0 rept-stat-card:mode=full:loc=1317 Command entered at terminal #13.;
eagle1 16-10-03 18:18:12 EST EAGLE 46.3.0.0.1-68.27.0 CARD VERSION TYPE GPL PST SST AST 1317 138-022-000 DSM SCCP64 IS-NR Active ----- ALARM STATUS = No Alarms. BLDC64 GPL version = 138-023-000 IMT BUS A = Conn IMT BUS B = Disc CLOCK A = Active CLOCK B = Fault CLOCK I = Idle MBD BIP STATUS = Valid MOTHER BOARD ID = SMXG B DBD STATUS = Valid DBD TYPE = None DBD MEMORY SIZE = 8192M HW VERIFICATION CODE = ---- CURRENT TEMPERATURE = 28C ( 83F) PEAK TEMPERATURE: = 32C ( 90F) [16-09-21 02:02] SCCP % OCCUP = 0% SCCP SM DATA TYPE = DN APPLICATION SERVICING MFC MFC
UAMs
UAM and UIM Troubleshooting Procedures 3-137
SNM REQ STATUS = 24 hr: ---, 5 min: --- INM REQ STATUS = 24 hr: ---, 5 min: --- MTP3 REQ STATUS = 24 hr: ---, 5 min: --- SFLOG REQ STATUS = 24 hr: ---, 5 min: --- IPLNK STATUS IPLNK IPADDR STATUS PST A 192.168.120.13 UP IS-NR B 192.168.121.13 UP IS-NR DSM IP CONNECTION PORT PST SST A IS-NR Active B IS-NR Active
Command Completed.;
e. Refer to the "EAGLE Feature and EPAP DB Capacity Combinations" table inDatabase Administration - GTT User's Guide to determine the maximum RTDBcapacity based on the installed hardware and EPAP Quantity features activatedin the system.
f. Do one of the following:
• Reduce the size of the database to match the installed hardware capacities.
• Obtain and install a larger capacity SM card.
• Obtain and activate the appropriate EPAP Quantity features.
• Verify that the SM card is running the appropriate GPL type (32-bit or 64-bit).
g. If the SM card requires 64-bit GPLs and the card is currently running 32-bitGPLs, see "Conversion of SM8G-B Cards" or "Conversion of SLIC Cards" inDatabase Administration - System Management User's Guide to convert 32-bit GPLsto 64-bit.
0449 - RTDB resynchronization in progress
This message indicates that the MPS database resynchronization is in process.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0449 ** CARD 1108 VSCCP RTDB resynchronization in progress
Alarm Level: Major
Recovery
When the resynchronization is complete, the RTDB database has beencorrected message is displayed.
0445 - RTDB database has been correctedNo further action is necessary
If the MPS has been inhibited, the generic clearing alarm 0500 is displayed.Otherwise, when the resynchronization is complete, the 0445 - RTDB databasehas been corrected message is displayed.
UAMs
3-138 EAGLE Unsolicited Alarm and Information Messages Reference
0450 - Invalid HW for Integrated GLS
The Integrated GLS Feature requires E5-based control cards. This UAM is generatedwhen legacy control cards are installed in the standby MASP location after theIntegrated GLS feature is turned on. This action changes the GLS subsystem state toIS-ANR.
Example
* 0002.0450 * GLS System Invalid HW for Integrated GLS
Alarm Level: Major
Recovery
Replace the legacy control cards (labeled GPSM-II and TDM on the cards) with E5-based control cards (labeled E5-MASP) when enabling the Integrated GLS Feature.
0451 - RTDB reload required
The RTDB database on the DSM card needs to be reloaded because the resynch logdoes not contain all of the required updates.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0451 ** CARD 1108 VSCCP RTDB reload required
Alarm Level: Major
Recovery
1. Enter the following command to verify the status of the RTDB:
rept-stat-db:display=all:db=mps
2. Enter the following command to correct the VSCCP card.
This command reinitializes the card and forces the card to load the current level ofthe database:
init-card:loc=xxxx
where xxxx is the location of the card identified in output.
3. When the reload is complete, the RTDB database has been correctedmessage is displayed.
0445 - RTDB database has been correctedNo further action is necessary
4. If the problem persists, contact the My Oracle Support (MOS).
0452 - Exceeded Service Error Threshold Lvl 1
This UAM is generated when the EAGLE 5 ISS detects SCCP or Application trafficfailure rates greater than the defined level 1 Service Error Threshold.
UAMs
UAM and UIM Troubleshooting Procedures 3-139
Note: UAM 527 is also expected when the errors exceed the threshold level(UAM452/453). These alarms are auto-cleared when the error condition abates(below threshold level1 for UAM 452 and level 2 for UAM 453)
Example
RLGHNCXA21W 00-11-07 11:02:30 EST EAGLE 35.0.0** 0014.0452 ** SCCP SYSTEM Exceeded Service Error Threshold Lvl 1
Alarm Level: Major
Recovery
1. Enter the following command to verify the database threshold:
rtrv-th-alm
2. Enter the following command to verify the Fail Ratio of the service in question:
rept-stat-sccp
3. Enter the following command up to three times to ensure all DSMs are acceptingupdates:
rept-stat-db:display=all:db=mps
• If the DSMs are accepting updates, proceed to 4.
• If the DSMs are not accepting the updates and they all stopped at the samelevel, inspect the respective EPAP or ELAP application attached to the EAGLE,and correct any issues on the EPAP or ELAP application.
4. Enter the following command to retrieve records from the active or standby Alarmand UIM logs generated by the Maintenance system:
rtrv-log:type=xxx
where: xxx=ALL, ALARM, or UIM.
For more information on available parameters, refer to the Commands Manual.
5. For further assistance, contact the My Oracle Support (MOS).
0453 - Exceeded Service Error Threshold Lvl 2
This UAM is generated when the EAGLE 5 ISS detects SCCP or Application trafficfailure rates greater than the defined level 2 Service Error Threshold.
Note: UAM 527 is also expected when the errors exceed the threshold level(UAM 452/453). These alarms are auto-cleared when the error conditionabates (below threshold level1 for UAM 452 and level 2 for UAM 453)
Example
RLGHNCXA21W 00-11-07 11:02:30 EST EAGLE 35.0.0*C 0014.0453 *C SCCP SYSTEM Exceeded Service Error Threshold Lvl 2
Alarm Level: Critical
UAMs
3-140 EAGLE Unsolicited Alarm and Information Messages Reference
Recovery
1. Enter the following command to verify the database threshold:
rtrv-th-alm
2. Enter the following command to verify the Fail Ratio of the service in question:
rept-stat-sccp
3. Enter the following command up to three times to ensure all DSMs are acceptingupdates:
rept-stat-db:display=all:db=mps
• If the DSMs are accepting updates, proceed to the next step.
• If the DSMs are not accepting the updates and they all stopped at the samelevel, inspect the respective EPAP or ELAP application attached to the EAGLE.Correct any issues on the EPAP or ELAP application.
4. Enter the following command to retrieve records from the active or standby Alarmand UIM logs generated by the Maintenance system:
rtrv-log:type=xxx
where: xxx=ALL, ALARM, or UIM.
For more information on available parameters, refer to the Commands Manual.
5. For further assistance, contact the My Oracle Support (MOS).
0455 - EIR Subsystem is not available
The EIR subsystem is not available. No IS-NRVSCCP cards are associated with thisEIR subsystem. No VSCCP cards have an Active EIR status; all are either out-ofservice (OOS) or loading. The EIR subsystem was not taken off-line via command.
Example
RLGHNCXA21W 03-08-18 12:01:43 EST EAGLE 35.0.0*C 0056.0455 *C EIR SYSTEM EIR Subsystem is not available
Alarm Level: Critical
Recovery
1. Enter the following command to verify the status and location of the subsystemcards:
rept-stat-mps
2. Enter the following command to move the VSCCP cards to an ACTIVE status ifloading is successful:
rst-card:loc=xxxx
where xxxx is the location of the OOS-MT-DSBLDVSCCP card(s) identified in 1.
3. Enter the following command to verify the status and location of the subsystemcards:
UAMs
UAM and UIM Troubleshooting Procedures 3-141
rept-stat-mps
4. Verify the VSCCP card(s) reset in 2 are IS-NR.
If not, reseat the card(s).
5. If any card(s) remain OOS-MT, replace the card(s).
Refer to the Maintenance manual for card removal/replacement procedures.
0456 - EIR Subsystem is disabled
The EIR subsystem has been manually disabled with the inh-map-ss command. AllIS-NR (in service normal) cards have EIR status of Offline, with at least one card IS-NR.
Example
RLGHNCXA21W 03-08-18 12:01:43 EST EAGLE 35.0.0*C 0056.0456 *C EIR SYSTEM EIR Subsystem is disabled
Alarm Level: Critical
Recovery
1. Enter the following command to verify the status and location of the EIRsubsystem cards:
rept-stat-mps
2. Enter the following command to reserve the subsystem number and to change thestate of the EIR subsystem status to on-line:
ent-ss-appl:appl=eir:ssn=xx:stat=online
where xx is primary subsystem number.
3. Enter the following command to change the state of the EIR subsystem to on-line:
alw-map-ss:ssn=xx
where xx is primary subsystem number.
4. Enter the following command to verify the status of the EIR subsystem:
rept-stat-mps
0460 - EIR Subsystem degraded, card(s) abnormal
One or more EIR cards goes out of service in (N or N+1) configuration or not IS-NR.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 46.0.00056.0460 EIR SYSTEM EIR Subsystem degraded, card(s) abnormal
Alarm Level: Major.
Recovery
1. Restore the one or more EIR out of service cards in (N or N+1) configuration or notIS-NR.
UAMs
3-142 EAGLE Unsolicited Alarm and Information Messages Reference
0466 - STC Network Unavailable
This indicates the network connected to the STC (port A/B) is inaccessible.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0466 ** CARD 1201 STC STC Network Unavailable
Alarm Level: Major
Recovery
Re-association should take place automatically.
If it does not, contact the My Oracle Support (MOS).
0468 - All STC Networks Unavailable
All connections off all the STC cards (port A/B) are inaccessible.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 *C 0014.0468 *C EROUTE System All STC Networks Unavailable
Alarm Level: Critical
Recovery
Re-association should take place automatically.
If it does not, contact the My Oracle Support (MOS).
0469 - All STC Cards Unavailable
All the STC cards are not accessible.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 *C 0014.0469 *C EROUTE System All STC Cards unavailable
Alarm Level: Critical
Recovery
1. Determine if all STC cards are out of service by entering the following command:
rept-stat-card
2. Reinitialize the STC cards by entering the following command:
init-card:appl=eroute
3. If the fault has not cleared, reseat each faulty STC card.
4. If the alarm is not cleared, contact the My Oracle Support (MOS).
Refer to the Maintenance manual for card removal/replacement procedures.
UAMs
UAM and UIM Troubleshooting Procedures 3-143
0473 - EROUTE System Capacity Exceeded
The EROUTE system has reached a rate higher than its capacity. There is thepossibility of a loss of traffic monitoring.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0473 ** EROUTE System EROUTE System Capacity Exceeded
Alarm Level: Major
Recovery
1. Decrease the number of links being monitored until more STC cards are added tothe System.
2. Refer to the Database Administration Manual - Features for the correct procedure onadding STC cards.
0482 - Card(s) have been denied EROUTE service
EROUTE service is being denied service because there is a shortage of STC cards.
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0482 ** EROUTE System Card(s) have been denied EROUTE service
Alarm Level: Major
Recovery
1. Enter the following command to determine the cards that are denied EROUTEservice: rept-stat-mon
2. Refer to the Database Administration Manual - Features for the correct procedure onadding STC cards.
0483 - DEIR System is not available
The S13 Feature is not ON or the System has no S23 card in ACTIVE/IS_NR.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 *C 0002.0483 *C DEIR SYSTEM DEIR System is not available
Alarm Level: Critical
Recovery
1. Activate (Active/IS-NR) any of the DEIR cards in the system.
0484 - DEIR System normal, card(s) abnormal
The number of active S13 cards ( i.e. in IS-NR state) is less than half the configured S13cards.
UAMs
3-144 EAGLE Unsolicited Alarm and Information Messages Reference
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 * 0002.0484 * DEIR SYSTEM DEIR System normal, card(s) abnormal
Alarm Level: Major
Recovery
1. Activate (Active/IS-NR) half or more DEIR cards in the system.
0485 - DEIR System is available
The number of active (Active/IS-NR) S13 cards is equal to or more than half of theconfigured S13 cards.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 0003.0485 DEIR SYSTEM DEIR System is available
Alarm Level: None
Recovery
No further action necessary.
0486 - DEIR Threshold - Level1 exceeded
The DEIR Card TPS has exceeded configured level-1 value in DEIROPTS.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 * 0002.0486 * DEIR SYSTEM DEIR Threshold - Level1 exceeded
Alarm Level: Minor
Recovery
1. Reduce the card TPS below configured level-1 value in DEIROPTS.
0487 - DEIR System Threshold - Level2 exceeded
The DEIR Card TPS has exceeded configured level-2 value in DEIROPTS.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 ** 0002.0487 ** DEIR SYSTEM DEIR System Threshold - Level2 exceeded
Alarm Level: Major
Recovery
UAMs
UAM and UIM Troubleshooting Procedures 3-145
1. Reduce Card TPS below configured level-2 value in DEIROPTS.
0488 - DEIR Threshold Condition Cleared
The DEIR Card TPS is below configured level-1 value in DEIROPTS..
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 0002.0488 DEIR SYSTEM DEIR Threshold Condition Cleared
Alarm Level: None
Recovery
No further action necessary.
0489 - DEIR capacity exceeded
The DEIR Card TPS has exceeded the maximum allowable cards TPS (8000).
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 *C 0002.0489 *C DEIR SYSTEM DEIR capacity exceeded
Alarm Level: Critical
Recovery
1. Reduce the card TPS below the overall cards TPS.
0490 - DEIR normal
The S13 card capacity has returned to normal.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 0002.0490 DEIR SYSTEM DEIR normal
Alarm Level: None
Recovery
No further action necessary.
0491 - Connection TPS exceeded
The connection present on the DEIR Card has exceeded the maximum allowableconnection TPS (MaxTPS) configured in the DCONN table.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890
UAMs
3-146 EAGLE Unsolicited Alarm and Information Messages Reference
** 0002.0491 ** DEIR SYSTEM Connection TPS exceeded
Alarm Level: Major
Recovery
1. Reduce the connection TPS to below the configured MaxTPS for that connection inthe DCONN table.
0492 - Connection TPS normal
The TPS on a connection present DEIR card is below or equal to the maximum allowedTPS (MaxTPS) configured in the DCONN table.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 0002.0492 DEIR SYSTEM Connection TPS normal
Alarm Level: None
Recovery
No further action necessary.
0493 - Diameter Connection Down
The SCTP association is Open (open=yes) and the Diameter connection status is down.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 ** 0004.0493 ** DCONN DCNAME1 Diameter Connection Down
Alarm Level: Major
Recovery
1. Get the diameter connection UP.
0494 - Diameter Connection UP
The SCTP association is Open (open=yes) and the Diameter connection status is UP.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 0003.0494 DEIR SYSTEM Diameter Connection UP
Alarm Level: None
Recovery
No further action is necessary.
UAMs
UAM and UIM Troubleshooting Procedures 3-147
0495 - Diameter Connection Closed
The Diameter connection or SCTP association for a diameter connection is closed.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 0002.0495 DEIR SYSTEM Diameter Connection Closed
Alarm Level: None
Recovery
No further action necessary.
0496 - DEIR System is removed
The last S13 card has been deleted from the system.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 0002.0496 DEIR SYSTEM DEIR System is removed
Alarm Level: None.
Recovery
No further action is necessary.
0497 - REPT-J1F:FAC-J1 LOS failure
This alarm is present when no signal is being received on the signaling link.
Example
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890** 0123.0497 ** J1PORT 1103,2 REPT-J1F:FAC-J1 LOS failure
Alarm Level: Major
Recovery
Check the physical connections.
0498 - REPT-J1F:FAC-J1 LOF failure
The 7-bit frame alignment signal does not match the pattern the EAGLE is expecting.
Example
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890** 0124.0498 ** J1PORT 1103,2 REPT-J1F:FAC-J1 LOF failure
Alarm Level: Major
UAMs
3-148 EAGLE Unsolicited Alarm and Information Messages Reference
Recovery
Contact the far-end office to correct their framing problem.
0499 - REPT-J1F:FAC-J1 Remote Alarm
This alarm is present when there is some type of failure on the far end.
Example
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890** 0125.0499 ** J1PORT 1103,2 REPT-J1F:FAC-J1 Remote Alarm
Alarm Level: Major
Recovery
Contact the far-end office to determine the cause and correct the problem.
0501 - OAM ITT sample Minor Alarm
This is an alarm clearing output that applies to Minor setting alarms. The alarm for theindicated device is being cleared.
Example
tekelecstp 01-01-19 14:56:48 EST EAGLE 34.00045.0501 DLK 1104,A1 Alarm for this entity is being cleared
Note: The output can vary significantly. The output varies depending onwhich device the alarm is being cleared. In this example the alarm is beingcleared for a Data Link.
Alarm Level: No alarm condition. The message is informational only.
Recovery
No further action is necessary.
0502 - OAM ITT sample Minor Alarm
This is an alarm clearing output that applies to Minor alarms. The alarm for theindicated device is being cleared.
Example
tekelecstp 01-01-19 14:56:48 EST EAGLE 34.00045.0502 DLK 1104,A1 Alarm for this entity is being cleared
Note: The output can vary significantly. The output varies depending onwhich device the alarm is being cleared. In this example the alarm is beingcleared for a Data Link.
Alarm Level: No alarm condition. The message is informational only.
Recovery
No further action is necessary.
UAMs
UAM and UIM Troubleshooting Procedures 3-149
0503 - OAM ITT sample Critical Alarm
This is an alarm clearing output that applies to Major alarms. The alarm for theindicated device is being cleared.
Example
tekelecstp 01-01-19 14:56:48 EST EAGLE 34.00045.0503 DLK 1104,A1 Alarm for this entity is being cleared
Note: The output can vary significantly. The output varies depending onwhich device the alarm is being cleared. In this example the alarm is beingcleared for a Data Link.
Alarm Level: No alarm condition. The message is informational only.
Recovery
No further action is necessary.
0504 - REPT-J1F:FAC-J1 Alarm
This alarm is present when the J1 port becomes unavailable.
Example
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890** 0126.0504 ** J1PORT 1103,2 REPT-J1F:FAC-J1 Alarm
Alarm Level: Major
Recovery
Contact the far-end office to determine the cause and correct the problem.
0505 - RRCVRY-J1F:FAC-J1 available
This alarm is present when the J1 port is back in-service.
Example
1 2 3 4 5 6 7 8123456789012345678901234567890123456789012345678901234567890123456789012345678900127.0505 J1PORT 1103,2 REPT-J1F::FAC-J1 available
Alarm Level: Normal
Recovery
None.
0506 - REPT-J1F:FAC-J1 unavailable
This alarm is present when the J1 port goes down.
Example
UAMs
3-150 EAGLE Unsolicited Alarm and Information Messages Reference
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890** 0128.0506 ** T1/J1PORT 1103,2 REPT-J1F::FAC-J1 unavailable
Alarm Level: Major
Recovery
When the J1 port becomes available.
0514 - Standby MASP inhibited
This message indicates that the standby OAM is inhibited. Database updates will berejected until the standby OAM is allowed.
Example
RLGHNCXA3W 00-11-06 10:55:49 EST EAGLE 35.0.0** 0076.0514 ** CARD 1115 OAM Standby MASP inhibited
Alarm Level: Major
Recovery
1. Verify the status of the OAM entering a rept-stat-card command.
2. Enter the following command to allow the card:
alw-card:loc=xxxx
where xxxx = card location (1115 or 1113)
3. If the card is restored, you have completed this procedure.
If the card is not restored, check and follow the output to correct the problem, thenenter the alw-card command.
4. If the problem persists, contact the My Oracle Support (MOS).
0517 - Degraded Mode - multiple cards failed
The Measurements Platform subsystem is degraded because more than one MCPMcard is out of service. The Measurements Platform subsystem can successfullycomplete all of its work, but may have no spare MCPM.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0** 0100.0517 ** MEAS SYSTEM Degraded Mode - multiple cards failed
Alarm Level: Major
Recovery
1. Enter the following command to determine the status of the MCPM cards:
rept-stat-meas
2. Reinitialize the faulty card using the command.
init-card
UAMs
UAM and UIM Troubleshooting Procedures 3-151
3. If the fault has not cleared, reseat the faulty card.
4. If the fault has not cleared, replace the faulty MCPM card.
5. Repeat 2 through 4 for each faulty MCPM card.
Refer to the Maintenance manual for card removal/replacement procedures.
0518 - Measurements subsystem unavailable
The Measurements Platform subsystem is not available. All MCPM cards are out ofservice.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0*C 0100.0518 *C MEAS SYSTEM Measurements subsystem unavailable
Alarm Level: Critical
Recovery
1. Enter the following command to determine the status of the MCPM cards:
rept-stat-meas
2. Reinitialize the faulty MCPM card using the init-card command.
3. If the fault has not cleared, reseat the faulty card.
4. If the fault has not cleared, replace the faulty MCPM card.
5. Repeat 2 through 4 for each faulty MCPM card.
Refer to the Maintenance manual for card removal/replacement procedures.
0520 - Frame power usage reached LVL3
Frame power usage reached 98% of threshold value.
Example
RLGHNCXA3W 00-11-06 10:55:49 EST EAGLE 35.0.0*C 0002.0520 *C FRAME CF01 Frame power usage reached LVL3
Alarm Level: Critical
Recovery
1. Verify that the Frame Power Threshold value is properly configured for the framefor which UAM is generated using the following command:
rtrv-frm-pwr
2. Verify that the card population is correct for that particular frame using thefollowing command:
rtrv-stp:display-power
3. Contact the My Oracle Support (MOS), about the generated UAM.
UAMs
3-152 EAGLE Unsolicited Alarm and Information Messages Reference
0521 - Frame power usage reached LVL2
Frame power usage reached 95% but is below 98% of threshold value.
Example
RLGHNCXA3W 00-11-06 10:55:49 EST EAGLE 35.0.0** 0002.0521 ** FRAME CF01 Frame power usage reached LVL2
Alarm Level: Major
Recovery
1. Verify that the Frame Power Threshold value is properly configured for the framefor which UAM is generated using the following command:
rtrv-frm-pwr
2. Verify that the card population is correct for that particular frame using thefollowing command:
rtrv-stp:display-power
3. Contact the My Oracle Support (MOS), about the generated UAM.
0528 - Service is not available
The specified SCCP service is not available. No IS-NRSCCP cards are associated withthis specified SCCP service. No SCCP cards providing the specified service have aservice status of Active.
Example
RLGHNCXA3W 00-11-06 10:55:49 EST EAGLE 34.3.0*C 0056.0528 *C GFLEX SERVICE Service is not available
Alarm Level: Critical
Recovery
1. Enter the following command to verify the status and location of the SCCP servicecards:
rept-stat-sccp
2. Enter the following command to move the SCCP service card to an ACTIVE statusif loading is successful:
rst-card:loc-xxxx
where: xxxx is the location of the OOS-MT-DSBLDSCCP card(s) identified in 1.
3. Enter the following command to verify the status and location of the SCCP servicecards:
rept-stat-sccp
4. Verify the SCCP card(s) reset in 2 are IS-NR.
If not, reseat the card(s).
UAMs
UAM and UIM Troubleshooting Procedures 3-153
5. If any card(s) remain OOS-MT, replace the card(s).
Note: Refer to the Maintenance manual for card removal/replacementprocedures. for card replacement procedures.
0529 - Service is disabled
The specified SCCP service has been manually disabled with the chg-sccp-servcommand. All IS-NR cards providing the service have service status of Offline.
Example
RLGHNCXA3W 00-11-06 10:55:49 EST EAGLE 34.3.0*C 0056.0529 *C GFLEX SERVICE Service is disabled
Alarm Level: Critical
Recovery
1. Enter the following command to verify the status and location of the SCCP servicecards:
rept-stat-sccp
2. Enter the following command to change the state of the SCCP service status to on-line:
chg-sccp-serv:serv-xxxx:state=online
where: xxxx is the SCCP service name.
3. Enter the following command to verify the status of the SCCP service cards:
rept-stat-sccp
0534 - RTX is prohibited
Traffic to the DPC through this exception route set is prohibited. Possible causes are asfollows:
• All routes in this exception route set are unavailable.
• Adjacent point code link failures or nonadjacent failure exist in the route.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890*C 0044.0534 *C RTXN24 001-101-001 RTX is prohibited ILSN=lsn012345
Alarm Level: Critical
Recovery
1. Enter the following command using the DPC and RTX class/criterion specifiedfrom the output message to determine which linkset has a problem:
rept-stat-rtx:dpc=<dpc>:<class>=<criterion>
UAMs
3-154 EAGLE Unsolicited Alarm and Information Messages Reference
2. Enter the following command using the linkset name specified from the output of 1to determine which link(s) could have a problem:
rept-stat-ls
3. Use local procedures to test the link facilities.
0537 - Ethernet error threshold exceeded
There are two types of error that can generate UAM 0537:
• Too much data received on the port.
• An Ethernet interface experiences excessive errors at the physical layer, such asCRC or framing errors. This error is issued when the Ethernet statistics indicateerrors occurring in any 15-second window. The alarm will clear when no errorshave occurred in the previous 15 second window. In full-duplex mode, collisionswill not be ignored but when configured for half-duplex mode, they will beignored, since collisions are expected in half-duplex mode. When collisions occurrepeatedly for the same packet more than 16 times then the “excess collisions”error count is pegged.
Example
RLGHNCXA21W 06-12-07 12:01:43 EST EAGLE 35.6.0 ** 2315.0537 ** ENET 1201,B Ethernet error threshold exceeded
Alarm Level: Major
Recovery
This error may be due to
• Too much incoming data for the port to handle.
• Faulty hardware; an EAGLE card, cable, or immediate IP switch/router.
• Configuration mismatch problems; the following items should match on bothends:
– Duplex
– Speed
– Ethernet type
– Autonegotiate used on EAGLE or immediate IP switch/router (it isrecommended to lock down your IP connection and do not useAUTONEGOTIATE)
1. Perform this step if UAM 0537 is issued and the card boots; otherwise, skip to 2. Ifthe card boots, the problem is probably too much incoming data on the port.Deactivate the port that has too much data using the dact-ip-lnk:loc=xxxx:port=xxxx command. Fix the network problem, then reactivatethe port using the act-ip-lnk:loc=xxxx:port=xxxx.
UAMs
UAM and UIM Troubleshooting Procedures 3-155
Note: An external hardware failure can cause IP overload on the portresulting in card boot. This problem is uncommon, but can occur when aproblem with the customer network overwhelms the Ethernet port with astorm of traffic. The solution is to resolve the network problem. The dact-ip-lnk:loc=xxxx:port=xxxx also makes it possible to deactivate a badEthernet port so the other port can work.
2. Use the following command to determine the current EAGLE configuration for theIP card reporting the errors.
rtrv-ip-lnk:loc=xxxx
wherexxxx is the card location identified in the error message.
3. Use the netstat -d pass command to view the driver statistics for the localinterface.
• For the A ethernet interface, pass:loc=XXXX:cmd="netstat -d 0"
• For the B ethernet interface, pass:loc=XXXX:cmd="netstat -d 1"
where xxxx is the card location identified in the error message.
Table 3-4 and Table 3-5 show the errors that show up on the DCM/DSM/EDCM/SSEDCM and E5-ENET/E5-ENET-B card types. Because the boards use differentethernet chips, the statistics that are available are different.
Table 3-4 See (DCM/DSM/EDCM/SSEDCM) Ethernet Error Statistics
Statistic Peg Description Half Duplexthreshold count
Full Duplexthreshold count
overflow Number of timesthe RX FIFOoverflowed forframes received.
1 1
CRC errors Number of framesreceived ordiscarded with CRCerrors but noframing errors.
1 1
short frame Number of framesreceived ordiscarded withcarrier sense or RX-D.V. activity lessthan the“ShortEventMaxTime” (74-82 bit times).
1 1
oversize frame Number of receiveframes with greaterthan the 1518 bytemaximum framesize.
1 1
UAMs
3-156 EAGLE Unsolicited Alarm and Information Messages Reference
Table 3-4 (Cont.) See (DCM/DSM/EDCM/SSEDCM) Ethernet Error Statistics
Statistic Peg Description Half Duplexthreshold count
Full Duplexthreshold count
terminal count Receive DMA triedto receive more thanthe buffer capacity.
1 1
excess collisions Number of times aframe collided 16times withoutsuccessfultransmission.
1 1
underflow Count of transmitunderflow errors.
1 1
CS error Number of timesthe transmitter hadtransmit dataavailable and wasready to transmitbut had to defertransmission due tocarrier sense goingHIGH. (Tx defercount in the Seedata sheet).
n/a 1
alignment error Number of framesreceived ordiscarded with botha framing error anda CRC error.
1 1
very long event Number of timesthe transmitter isactive for greaterthan the MAUJabber LockupProtection Timerallows ([4-7ms] at 10Mbit and [0.4 –0.75ms] at 100 Mb.11rxerrorNumber oftimes RXERR isasserted by theEthernet PHY.
1 1
num_job_q_full Number of timesthe net task jobqueue was full.
1 1
rxerror Number of timesRXERR is assertedby the EthernetPHY.
1 1
UAMs
UAM and UIM Troubleshooting Procedures 3-157
Table 3-5 GEI (E5-ENET/E5-ENET-B) Ethernet Error Statistics
Statistic Peg Description Half Duplexthreshold count
Full Duplexthreshold count
crcerrs Number of receiveframes with CRCerrors.
1 1
algnerrc Number of receiveframes withalignment errors(the frame is not aninteger number ofbytes in length).
1 1
rxerrc Number of framesreceived in whichI_RX_ER wasasserted by the PHY.
1 1
ecol When 16 or morecollisions haveoccurred on a frame,this registerincrements,regardless of thevalue of collisionthreshold.
1 1
tncrs This register countsthe number ofsuccessful frametransmissions inwhich the internalcarrier sense signalfrom the PHY wasnot asserted withinone slot time of startof transmission.
n/a 1
tuc Transmit underruncount.
1 1
rlec This register countsreceive length errorevents.
1 1
rnbc The number oftimes that frameswere received whenthere were noavailable buffers inhost memory tostore those frames.
1 1
UAMs
3-158 EAGLE Unsolicited Alarm and Information Messages Reference
Table 3-5 (Cont.) GEI (E5-ENET/E5-ENET-B) Ethernet Error Statistics
Statistic Peg Description Half Duplexthreshold count
Full Duplexthreshold count
ruc This register countsthe number ofreceived frames thatpassed addressfiltering, and wereless than minimumsize (64 bytes from<DestinationAddress> through<CRC>,inclusively), andhad a valid CRC.
1 1
roc This register countsthe number ofreceived frameswith valid CRC fieldthat passed addressfiltering, and weregreater thanmaximum size.
1 1
4. If the error is due to configuration problems, correct the configurationso theEAGLE and the IP switch/router match.
5. If the configuration matches on both ends of the IP segment, replace the EAGLEcard as identified in the error message.
If replacing the card does not fix the issue, begin local procedures to verify the localIP segment.
0539 - Ethernet Interface Down
An Ethernet interface is reporting that it is down.
Example
RLGHNCXA21W 06-12-09 12:01:43 EST EAGLE 40.1 ** 2315.0539 ** DLK 1201,B1 IPSG Ethernet Interface Down
Alarm Level: Major
Recovery
An Ethernet interface is provisioned (rtrv-ip-lnk reports a non-zero IP address andthe card on which the Ethernet resides is in service), but the interface is reporting thatit is down.
If this UAM comes from the E5-OAM card and rept-stat-meas command outputshows this E5-OAM card as Primary, a loss of reports on the measurement server ispossible and MASP swap must be done manually.
If this UAM comes from the E5-OAM card, rept-stat-card shows this card isactive, and rtrv-ctrl-feat command output shows the SNMP feature is activated,a loss of SNMP traps is possible. MASP swap must be done manually.
UAMs
UAM and UIM Troubleshooting Procedures 3-159
0541 - MSU cksum error threshold exceeded
One or more MSU checksum validation errors have been reported by a LIM or SCCPcard during internal card integrity checks.
A LIM or SCCP card has reported a checksum validation failure for a MSU receivedfrom another card. The failure may be due to a hardware problem or other issueaffecting the data transfer path on a particular card. It may indicate a problem withdata corruption in an MSU sent to or received from another card.
The alarm is raised when a checksum validation failure occurs during internal cardintegrity checks. It remains active in the system until the Run-Time Diagnosticsubsystem (RTD) statistics are reset and no further indications of MSU checksumvalidation failures are reported.
Example
RLGHNCXA21W 06-12-07 12:01:43 EST EAGLE 35.6.0 *C 2315.0541 *C RTD SYSTEM MSU cksum error threshold exceeded
Alarm Level: Critical
Recovery
1. Issue the following command with no parameters to obtain the Run-TimeDiagnostic subsystem (RTD) report.
Note: Save all command outputs and reports obtained during this procedureto provide to My Oracle Support (MOS).
rept-stat-rtd
Following is an example output of the rept-stat-rtd command.
RLGHNCXA21W 06-12-07 12:01:43 EST EAGLE 35.6.0 Retrieving data from the cards…
RTD SUBSYSTEM REPORT IS-ANR Active ----- RTD ALARM STATUS = 541 MSU cksum error threshold exceeded MSU Validation Statistics ============================== Total Rx Total Rx Total CARD Error Validated Tx 1101 275 275 710 1102 0 200 200 1103 0 200 1000 1105 0 1360 275 1107 0 200 100 1108 0 100 100
2. Record the timestamp reported for the alarm.
3. Record the locations for cards reporting 1 or more errors in the Total Rx Errorcolumn.
4. Determine if a single error or multiple errors were reported when the alarmoccurred.
UAMs
3-160 EAGLE Unsolicited Alarm and Information Messages Reference
• Multiple errors - if multiple cards report errors or a single card reports morethan 1 error in the Total Rx Error column.
• Single error - if only 1 card reports errors and the value in the Total RxError column is 1.
5. Issue the following command for each card reporting 1 or more errors in 1
rept-stat-rtd:loc=xxxx
Where xxxx is the card location determined from the output in 1.
The following is an example output of a card summary for card 1101.
rept-stat-rtd:loc=1101
RLGHNCXA21W 06-12-07 12:01:43 EST EAGLE 35.6.0 Retrieving data from card …
CARD SUMMARY: 1101 Last Alarm Timestamp: 06-12-07 12:01:43 MSU Validation Statistics ================================= Total Rx Total Rx Total Tx SRC/DEST Error Validated CARD 1102 100 100 100 1103 0 0 0 1105 75 75 360 1107 100 100 200 1108 0 50 50
6. Issue the following command to clear the RTD statistics
rept-stat-rtd:reset=yes:force=yes
Following is an example output of the command.
rept-stat-rtd:reset=yes
RLGHNCXA21W 06-12-07 12:09:43 EST EAGLE 35.6.0 Reset all RTD statistics sent to each card
COMMAND COMPLETE
7. Issue the following command with no parameters to obtain the Run-TimeDiagnostic subsystem (RTD) report.
rept-stat-rtd
Following is an example output of the command showing no alarms.
RLGHNCXA21W 06-12-07 12:10:43 EST EAGLE 35.6.0 Retrieving data from the cards…
RTD SUBSYSTEM REPORT IS-NR Active ----- RTD ALARM STATUS = No Alarms MSU Validation Statistics ============================== Total Rx Total Rx Total CARD Error Validated Tx
UAMs
UAM and UIM Troubleshooting Procedures 3-161
1101 0 275 710 1102 0 200 200 1103 0 200 1000 1105 0 1360 275 1107 0 200 100 1108 0 100 100
Note that the alarm did clear.
8. Have all command outputs and reports obtained during this procedure available.
This information will be used by the Customer Care Center in determining thecause of the alarm and monitoring the system for errors.
9. If RTD alarm status reported in step 7 indicates that the alarm did not clear, thenproceed with below steps. Otherwise, continue to 26
10. Enter the rtrv-log:dir=bkwd:snum=1355:num=10 command to retrieve the10 latest UIM 1355 records.
11. Count the total number of times a particular card location appeared in the 10 UIM1355 samples collected in the previous step, either as the source or as thedestination location.
For example, if card 1102 appeared as the source location in 4 UIM 1355 samples,and card 1102 appeared as the destination location in 6 UIM 1355 samples, thencard 1102 appeared a total of 10 times in 10 UIM 1355 samples.
12. Notify My Oracle Support (MOS) of the occurrence of the alarm immediately ifnone of the locations appeared exactly 10 times. Otherwise, proceed with the nextstep.
13. If more than one location appeared 10 times, go to step 18. If only one card locationappeared 10 times, then go to the next step.
14. Inhibit the card location that appeared 10 times.
15. Enter the rept-stat-rtd:reset=yes:force=yes command to reset the RTDalarm.
16. Enter the rept-stat-rtd command to verify the RTD alarm status.
17. Notify My Oracle Support (MOS) of the occurrence of the alarm immediately if theprevious steps did not clear the RTD alarm. Otherwise, go to 26.
18. Inhibit the card location that appeared 10 times as the source card location in theUIM 1355 samples collected in 10.
19. Enter the rept-stat-rtd:reset=yes:force=yes command to reset the RTDalarm.
20. Enter the rept-stat-rtd command to verify the RTD alarm status.
21. If the previous steps did not clear the RTD alarm, allow the card location that waspreviously inhibited and bring it back in service.
22. Inhibit the card location that appeared 10 times as the source card location in theUIM 1355 samples collected in 10.
UAMs
3-162 EAGLE Unsolicited Alarm and Information Messages Reference
23. Enter the rept-stat-rtd:reset=yes:force=yes command to reset the RTDalarm.
24. Enter the rept-stat-rtd command to verify the RTD alarm status.
25. Notify My Oracle Support (MOS) of the occurrence of the alarm immediately if theprevious steps did not clear the RTD alarm. Otherwise, go to the next step.
26. Notify My Oracle Support (MOS) of the occurrence of the alarm within 1 businessday, along with captures covering the recovery steps performed and all necessarysystem logs (UIM, UAM, seculog, trouble, obit, etc.) covering the incident.
0546 - SEAS Terminal Unavailable
This message indicates that the EAGLE 5 ISS system is unable to communicate withthe SEAS subsystem.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 37.5.0* 0043.0546 ** TERMINAL 17 SEAS Terminal Unavailable
Alarm Level: Major
Recovery
1. Enter the following command to determine the status of the SEAS terminal(s):
rept-stat-seas
Following are some examples of possible outputs:
• Both Terminals Down (Duplex)
> rept-stat-seas
tekelecstp 20-01-16 12:50:00 GMT UNKNOWN ??.?.?-58.32.0 rept-stat-seas Command entered at terminal #25. ;
Command Accepted - Processing tekelecstp 20-01-16 12:50:00 GMT UNKNOWN ??.?.?-58.32.0 SEAS SYSTEM PST SST AST ------------------------------------------------------------------------- OOS-MT Fault -----
ALARM STATUS = *C 0349 SEAS unavailable
TERM IPADDR PORT PST SST AST ------------------------------------------------------------------------- 26 192.168.63.235 1600 OOS-MT Disc -----
ALARM STATUS = ** 0546 SEAS Terminal unavailable
24 192.168.63.235 1700 OOS-MT Disc
UAMs
UAM and UIM Troubleshooting Procedures 3-163
-----
ALARM STATUS = ** 0546 SEAS Terminal unavailable
Command Completed. ;
• One Terminal Up (Duplex)
> rept-stat-seas
tekelecstp 20-01-16 12:50:00 GMT UNKNOWN ??.?.?-58.32.0 rept-stat-seas Command entered at terminal #25. ;
Command Accepted - Processing tekelecstp 20-01-16 12:50:00 GMT UNKNOWN ??.?.?-58.32.0 SEAS SYSTEM PST SST AST ------------------------------------------------------------------------- IS-ANR Restrict -----
ALARM STATUS = ** 0348 SEAS is at min service limit
TERM IPADDR PORT PST SST AST ------------------------------------------------------------------------- 26 192.168.63.235 1600 IS-NR Active -----
ALARM STATUS = No Alarms.
24 192.168.63.235 1700 OOS-MT Disc -----
ALARM STATUS = ** 0546 SEAS Terminal unavailable
Command Completed. ;
• One Terminal Down (Simplex)
> rept-stat-seas
tekelecstp 20-01-16 12:50:00 GMT UNKNOWN ??.?.?-58.32.0 rept-stat-seas Command entered at terminal #25. ;
Command Accepted - Processing tekelecstp 20-01-16 12:50:00 GMT UNKNOWN ??.?.?-58.32.0 SEAS SYSTEM PST SST AST ------------------------------------------------------------------------- OOS-MT Fault
UAMs
3-164 EAGLE Unsolicited Alarm and Information Messages Reference
-----
ALARM STATUS = *C 0349 SEAS unavailable
TERM IPADDR PORT PST SST AST ------------------------------------------------------------------------- 26 192.168.63.235 1600 OOS-MT Disc -----
ALARM STATUS = ** 0546 SEAS Terminal unavailable
Command Completed.
Refer to the Commands Manual to interpret the output.
2. Verify that the IP addresses and ports are correct.
Correct any discrepancy found.
3. Check the physical connections.
See the Installation Manual for more information about these system components. Ifthe connections are firmly seated.
4. Check for any fuse alarms on the Fuse and Alarm Panel in the frame.
5. Check that all terminals for the IPSM card are inhibited before inhibiting the cardfor replacement.
6. Replace the E5-IPSM card. Refer to the Maintenance manual for card removal/replacement procedures.
0547 - Service degraded
One or more SS cards goes out of service in (N or N+1) configuration or not IS-NR.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 46.0.00056.0547 APSS Service degraded
Alarm Level: Major.
Recovery
1. Restore the one or more SS out of service cards in (N or N+1) configuration or notIS-NR.
0548 - GTT HexTree DB corrupted. TPS derated
This message indicates there is a memory corruption in the HexTree DB that isaffecting the lookup of GTT translations.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 ** 0002.0548 ** CARD 1203 GTT HexTree DB corrupted. TPS derated
UAMs
UAM and UIM Troubleshooting Procedures 3-165
Alarm Level: No alarm condition. The message is informational only.
Recovery
Reboot the card or turn OFF GTTHITPS.
0549 - GTT HexTree DB incoherent. TPS derated
This message indicates the HexTree DB could not be updated successfully on theRADB command and the DB is incoherent..
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 ** 0002.0549 ** CARD 1203 GTT HexTree DB incoherent. TPS derated
Alarm Level: No alarm condition. The message is informational only.
Recovery
Reboot the card or turn OFF GTTHITPS.
0550 - GTT HexTree DB alarm cleared
This message indicates the HexTree DB error has been cleared.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 0002.0550 CARD 1203 GTT HexTree DB alarm cleared
Alarm Level: No alarm condition. The message is informational only.
Recovery
This message indicates a previous fault has been corrected.
No further action is necessary.
0551 - V-Flex Subsystem is not available
No SCCP cards have a V-Flex status of Active. (All SCCP cards are OOS or loading)
Example
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 37.6.0 *C 0056.0551 *C VFLEX SYSTEM VFLEX Subsystem is not available
Alarm Level: Critical.
Recovery
1. The V-Flex feature must be turned on and activated.
0552 - V-Flex Subsystem is disabled
All IS-NR SCCP cards have V-Flex status of Offline (with at least 1 card IS-NR). INH-MAP-SS command has been executed.
Example
UAMs
3-166 EAGLE Unsolicited Alarm and Information Messages Reference
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 37.6.0 *C 0056.0552 *C VFLEX SYSTEM VFLEX Subsystem is disabled
Alarm Level: Critical.
Recovery
1. The V-Flex feature must be enabled and turned on.
0556 - V-Flex Subsystem degraded, card(s) abnormal
One or more V-Flex cards goes out of service in (N or N+1) configuration or not IS-NR.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 46.0.00056.0556 VFLEX Subsystem VFLX Subsystem degraded, cards abnormal
Alarm Level: Major.
Recovery
1. Restore the one or more V-Flex out of service cards in (N or N+1) configuration ornot IS-NR.
0561 - Can't establish Hi Bit rate;All HW OK
This message is issued if the system cannot establish high bit rate operation when it isequipped with HIPR2 cards at all MUX locations and the HIPR2 High Rate Modefeature is ON.
Note: This UAM might appear during transition phase when the HIPR2 HighRate Mode feature status has changed, but eventually it will be cleared if highbit rate is established on both IMT buses.
Example
RLGHNCXA21W 09-02-07 12:01:43 EST EAGLE 41.1.0*C 5025.0561 *C SYSTEM Can't establish Hi Bit rate;All HW OK
Alarm Level: Critical
Recovery
1. Verify the status of the cards using the command: rept-stat-mux.
Example of the output:
CARD TYPE PST SST AST BITRATE BITRATE (OPER) (ACT) ------------------------------------------------------------------------ 1109 HIPR2 IS-ANR Restrict ----- HIGH LOW 1110 HIPR2 IS-NR Active ----- HIGH HIGH 1209 HIPR2 IS-ANR Restrict ----- HIGH LOW 1210 HIPR2 IS-NR Active ----- HIGH HIGH 1309 HIPR2 IS-ANR Restrict ----- HIGH LOW 1310 HIPR2 IS-NR Active ----- HIGH HIGH Command Completed.
UAMs
UAM and UIM Troubleshooting Procedures 3-167
2. Replace any faulty HIPR2 cards with a new HIPR2 card.
Refer to the Maintenance manual, Appendix A, Card Removal/Replacement Proceduresfor information on replacing the HIPR2 cards.
3. If the alarm does not clear, contact the My Oracle Support (MOS).
0563 - IMT Bit rate mismatch detected
This message indicates that the the IMT Bus A and B are operating at different bitrates. This can occur if the BERT Test fails for only one bus, or if some of the HIPR2cards have been replaced with HMUX/HIPR cards after the HIPR2 High Rate Modefeature was turned ON.
Note: This UAM might appear during transition phase when the HIPR2 HighRate Mode feature status has changed, but eventually it will be cleared if highbit rate is established on both IMT buses.
Example
RLGHNCXA21W 09-02-07 12:01:43 EST EAGLE 41.1.0** 0590.0563 ** IMT SYSTEM IMT Bit rate mismatch detected
Alarm Level: Major
Recovery
1. Verify the card status. Enter this command: rept-stat-mux.
Example of the output:
CARD TYPE PST SST AST BITRATE BITRATE (OPER) (ACT) ------------------------------------------------------------------------ 1109 HIPR2 IS-ANR Restrict ----- HIGH LOW 1110 HIPR2 IS-NR Active ----- HIGH HIGH 1209 HIPR2 IS-ANR Restrict ----- HIGH LOW 1210 HIPR2 IS-NR Active ----- HIGH HIGH 1309 HIPR2 IS-ANR Restrict ----- HIGH LOW 1310 HIPR2 IS-NR Active ----- HIGH HIGH Command Completed.
2. Enter the command to verify the IMT status: rept-stat-imt.
Example of the output:
IMT PST SST AST A IS-ANR Restrict ----- ALARM STATUS = No alarms
IMT PST SST AST B IS-NR Active ----- ALARM STATUS = No alarms
Command Completed.
3. Replace the faulty HIPR2 card or replace the HMUX/HIPR cards with HIPR2cards.
UAMs
3-168 EAGLE Unsolicited Alarm and Information Messages Reference
0565 - ATINPQ Subsystem is not available
The ATINP subsystem is not available. There are no IS-NR SCCP cards associated withthis ATINP subsystem. The ATINP subsystem was not taken off-line via command.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 39.2.0*C 0056.0565 *C ATINP SYSTEM ATINPQ Subsystem is not available
Alarm Level: Critical
Recovery
1. Enter the following command to verify the status and location of the subsystemcards:
rept-stat-mps
2. Enter the following command to move the SCCP cards to an ACTIVE status ifloading is successful:
rst-card:loc=xxxx
where xxxx is the location of the OOS-MT-DSBLD SCCP card(s) identified in 1.
3. Enter the following command to verify the status and location of the subsystemcards:
rept-stat-mps
4. Verify the SCCP card(s) reset in 2 are IS-NR.
If not, reseat the card(s).
5. If any card(s) remain OOS-MT, replace the card(s).
Refer to the Maintenance manual for card removal/replacement procedures.
0566 - ATINPQ Subsystem is disabled
The ATINP subsystem has been manually disabled using the inh-map-ss command.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 39.2.0*C 0056.0566 *C ATINP SYSTEM ATINPQ Subsystem is disabled
Alarm Level: Critical
Recovery
1. Enter the following command to verify the status and location of the ATINPsubsystem cards:
rept-stat-mps
2. Enter the following command to to reserve the subsystem number and to changethe state of the ATINP subsystem status to on-line:
ent-ss-appl:appl=ATINPQ:ssn=xx:stat=online
UAMs
UAM and UIM Troubleshooting Procedures 3-169
where xx is primary subsystem number.
3. Enter the following command to activate the ATINP subsystem and to bring it on-line:
alw-map-ss:ssn=xx
where xx is primary subsystem number.
4. Enter the following command to verify the status of the ATINP subsystem:
rept-stat-mps
0570 - Incompatible flash image for sys rel
The new card inserted into system with a flash image is not compatible with thesystem release. The card is auto-inhibited. A manual flash download is required.
Example
isht01 09-07-21 09:19:16 EST EAGLE5 41.1 ALARM STATUS = ** 0570 Incompatible flash image for sys rel 99 Inserted H/W is not compatible with the provisioned slot HW VERIFICATION CODE: 98
Alarm Level: Major
Recovery
1. Enter the command to load and activate the approved GPL onto the inhibited card:
flash-card:code=appr:loc=xxxx:force=yes
where xxxx is the card location used in the previous step. The optional force=yesis used to force the command to work on an IS-NR card. Links provisioned on thecard are inhibited during command execution. The card and inhibited links arerestored to their previous state when the command is completed.
Example of the output using card location 1105:
tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Downloading BLBIOS on card 1105.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Card 1105 download BLBIOS complete.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Downloading BLDIAG on card 1105.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Card 1105 download BLDIAG complete.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Downloading PLDE1T1 on card 1105.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Card 1105 download PLDE1T1 complete.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Downloading IMTPCI on card 1105.
UAMs
3-170 EAGLE Unsolicited Alarm and Information Messages Reference
; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Card 1105 download IMTPCI complete.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Downloading BLVXW on card 1105.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Card 1105 download BLVXW complete.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Downloading PLDPMC1 on card 1105.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Card 1105 download PLDPMC1 complete.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Activating BLBIOS on card 1105.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Card 1105 activation BLBIOS complete.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Activating BLDIAG on card 1105.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Card 1105 activation BLDIAG complete.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Activating PLDE1T1 on card 1105.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Card 1105 activation PLDE1T1 complete.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Activating IMTPCI on card 1105.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Card 1105 activation IMTPCI complete.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Activating BLVXW on card 1105.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Card 1105 activation BLVXW complete.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Activating PLDPMC1 on card 1105.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Card 1105 activation PLDPMC1 complete.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Downloading BLCPLD on card 1105.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Card 1105 download BLCPLD complete.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Activating BLCPLD on card 1105.;
UAMs
UAM and UIM Troubleshooting Procedures 3-171
tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Card 1105 activation BLCPLD complete.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Command Completed.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Canceling links on card 1105.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Inhibiting card 1105.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 Rel 34.0.0 Flash Card: Downloading BPMPL on card 1105.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Card 1105 download BPMPL complete.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Allowing card 1105.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Activating BPMPL on card 1105.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Card 1105 activation BPMPL complete.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Flash Card: Activating links on card 1105.; tekelecstp 05-04-11 01:52:11 EST EAGLE5 34.0.0 Command Completed.;
2. Enter the command to put the card that was inhibited in 1 back into service:
alw-card:loc=xxxx
where xxxx is the card location used in 1.
Example of the output:
RLGHNCXA03W 00-06-05 11:11:28 EDT EAGLE 35.0.0Card has been allowed.
Note: Allow the card to run for 5 minutes before continuing.
3. Enter the command to activate all links on the card.
act-slk:loc=xxxx:link=y
where xxxx is the card location identified in the output and y is the link.
4. Enter the command to verify all links on the card are active.
rept-stat-slk:loc=xxxx:link=y
where xxxx is the card location identified in the output and y is the link
5. Enter the command to verify the approved GPLs match the running GPLs:
UAMs
3-172 EAGLE Unsolicited Alarm and Information Messages Reference
rept-stat-gpl:gpl=xxxxxxx
where xxxxxxx is the GPL identified in the output.
6. If the GPLs match, you have completed this procedure.
If the GPLs do not match, continue with the following step.
7. Repeat this procedure for each card that shows ALM in the output.
8. If the same card shows in an alarm condition after executing the procedure, pleasecontact the My Oracle Support (MOS).
0573 - BERT Test Failed
This message is displayed when the BERT diagnostic test, which is initiated by theHIPR2 card as a part of the IMT bus alignment process, has failed. This message mayindicate that a HIPR2 card has failed; it may also indicate that there is a bad high rateFibre-Channel cable, or that the high rate Fibre-Channel cables have not been installed.
Example
RLGHNCXA21W 09-02-07 12:01:43 EST EAGLE 41.1.0** 0590.0573 ** Card 1109 BERT Test Failed
Alarm Level: Major
Recovery
1. Determine the status of the HIPR2 cards using the command: rept-stat-mux.
Replace any faulty HIPR2 card with a new HIPR2 card.
2. Verify that the high rate Fibre-Channel cables have been installed.
3. Inspect the cables and verify that the cable connections are secure.
4. The BERT test will run again during the bus alignment. Once the BERT Test issuccessful, the alarm will be cleared.
5. Contact the My Oracle Support (MOS) for more information.
0575 - Card type not HIPR2
This message is displayed when the HIPR2 High Rate Mode feature is ON and a non-HIPR2 card has replaced the HIPR2 card.
Example
RLGHNCXA21W 09-02-07 12:01:43 EST EAGLE 41.1.0** 0590.0575 ** Card 1309 Card type not HIPR2
Alarm Level: Major
Recovery
This alarm will be cleared when:
1. The HIPR/HMUX card is replaced with a HIPR2 card.
2. The HIPR2 High Rate Mode feature is turned OFF.
UAMs
UAM and UIM Troubleshooting Procedures 3-173
0576 - All FC Network Unavailable
This indicates that the FC Network is down on all FC enabled cards.
Example
RLGHNCXA21W 00-12-09 12:01:43 EST EAGLE 40.1 ** 0100.0576 ** FCS All FC Network Unavailable
Alarm Level: Major
Recovery
Re-association should take place automatically.
If it does not, contact the My Oracle Support (MOS).
0588 - FC Port De-activated
This indicates that FC enabled Card CPU Idle reached Threshold level 1 anddeactivated the FCS IP port (see Example 1) or if negotiation for data rate and trafficflow do not result in 100 Mbps and full duplex mode for the FC port (see Example 2).
Example 1
RLGHNCXA21W 00-12-09 12:01:43 EST EAGLE 40.1** 0705.0588 ** DLK 1106,B1 IPSG FC Port De-activated REASON: Onset of CPU Congestion
Example 2
RLGHNCXA21W 00-12-09 12:01:43 EST EAGLE 40.1 ** 0772.0588 ** DLK 1106,B1 IPSG FC Port De-activated REASON: Auto-Neg Fails
Alarm Level: Major
Recovery - Onset of CPU Congestion
No action necessary.
Recovery - Auto-Negotiation Fails
Corrective action needs to be taken at the switch to auto-negotiate successfully withFast Copy Ports, for data rate and traffic as 100 Mbps/Full Duplex.
0592 - AIQ Subsystem is not available
The AIQ subsystem is not available. There are no IS-NR SCCP cards associated withthis AIQ subsystem. The AIQ subsystem was not taken off-line via command.
Example
RLGHNCXA21W 00-02-10 12:01:43 EST EAGLE 42.0.0*C 0135.0592 *C LSS AIQ Subsystem is not available;
Alarm Level: Critical
Recovery
1. Enter the following command to verify the status and location of the subsystemcards:
UAMs
3-174 EAGLE Unsolicited Alarm and Information Messages Reference
rept-stat-sccp
2. Enter the following command to move the SCCP cards to an ACTIVE status ifloading is successful:
rst-card:loc=xxxx
where xxxx is the location of the OOS-MT-DSBLD SCCP card(s) identified in 1.
3. Enter the following command to verify the status and location of the subsystemcards:
rept-stat-sccp
4. Verify the VSCCP card(s) reset in 2 are IS-NR.
If not, reseat the card(s).
5. If any card(s) remain OOS-MT, replace the card(s).
Refer to the Maintenance manual for card removal/replacement procedures.
0593 - AIQ: Subsystem is disabled
The AIQ subsystem has been manually disabled using the inh-map-ss command.
Example
RLGHNCXA21W 00-02-10 12:01:43 EST EAGLE 42.0.0*C 1571.0593 *C LSS AIQ Subsystem is disabled;
Alarm Level: Critical
Recovery
1. Enter this command to verify the status and location of the AIQ subsystem cards:
rept-stat-sccp
2. Enter this command to to reserve the subsystem number and to change the state ofthe AIQ subsystem status to on-line:
ent-ss-appl:appl=aiq:ssn=xx:stat=online
where xx is primary subsystem number.
3. Enter this command to change the state of the AIQ subsystem to on-line:
alw-map-ss:ssn=xx
where xx is primary subsystem number.
4. Enter this command to verify the status of the AIQ subsystem:
rept-stat-sccp
0598 - Subsystem degraded, card(s) abnormal
One or more SS cards goes out of service in (N or N+1) configuration or not IS-NR.
Example
UAMs
UAM and UIM Troubleshooting Procedures 3-175
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 46.0.00056.0598 Subsystem Subsystem degraded, cards abnormal
Alarm Level: Major.
Recovery
1. Restore the one or more SS out of service cards in (N or N+1) configuration or notIS-NR.
0619 - SIP SYSTEM is not available
This alarm indicates SIP feature is not ON and System has no SIP card that isActive/IS-NR.
Example
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890 *C 0002.0619 *C SIP SYSTEM SIP System is not available
Alarm Level: Critical
Recovery
1. Enter the following command to verify the status and location of the SIP card:rept-stat-sip.
2. Enter the following command to move the SIP card to an ACTIVE status if loadingis successful: rst-card:loc=xxx where xxxx is the location of the SIP cardidentified in Step 1.
3. Enter the following command to verify the status and location of the SIP card:rept-stat-sip.
4. Verify the SIP card reset in 2 are ACTIVE/IS-NR.
5. If the SIP card remains INACTIVE, replace the card. Refer to Maintenance Guide forcard removal/replacement procedures.
0620 - SIP SYSTEM is available
This message indicates that at least one SIP card is ACTIVE/IS-NR.
Example
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890 0002.0620 SIP SYSTEM SIP SYSTEM is available
Alarm Level: No alarm condition. The message is informational only.
Recovery
No further action is necessary.
0622 - SIP Threshold - Level1
This UAM is generated when the EAGLE detects SIP Congestion Level 1 based on thethreshold set in TH-ALM table for the SIP card.
UAMs
3-176 EAGLE Unsolicited Alarm and Information Messages Reference
Example
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890 0002.0622 SIP SYSTEM SIP Threshold - Level1
Alarm Level: Minor
Recovery
1. Use rept-stat-sip command to determine the status of the SIP SYSTEM. If theTPS is beyond the allowed limit, decrease the TPS.
2. Follow the procedures to add more SIP cards to handle the increased SIP traffic.
0623 - SIP Threshold - Level2
This UAM is generated when the EAGLE 5 detects SIP Congestion Level 2 based onthe threshold set in TH-ALM table for the SIP card.
Example
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890 0002.0623 SIP SYSTEM SIP Threshold - Level2
Alarm Level: Major
Recovery
1. Use rept-stat-sip command to determine the status of the SIP SYSTEM. If theTPS is beyond the allowed limit, decrease the TPS.
2. Follow the procedures to add more SIP cards to handle the increased SIP traffic.
0624 - SIP Threshold Condition Cleared
This UAM is generated when the SIP Threshold congestion is cleared.
Example
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890 0002.0624 SIP SYSTEM SIP Threshold Condition Cleared
Alarm Level: No Alarm Condition.
Recovery
This alarm indicates a previous fault has been corrected.
No further action is necessary.
0625 - SIP SYSTEM normal, card(s) abnormal
This message indicates that the number of active SIP cards (i.e. in IS-NR state) is lessthan half of the configured SIP cards.
Example
UAMs
UAM and UIM Troubleshooting Procedures 3-177
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890 0002.0625 SIP SYSTEM SIP SYSTEM normal, card(s) abnormal
Alarm Level: NO alarm condition. The message is informational only.
Recovery
1. Enter the following command to determine which SIP cards are out of service:rept-stat-sip.
2. Use the init-card command to reinitialize any SIP cards OOS-MT.
3. Use the rept-stat-sip command again to determine if the card(s) have returnedto IS-NR. If not, reseat the card(s).
4. If the SIP card remains OOS-MT, replace the card(s). Refer to Maintenance for cardremoval/replacement procedures.
0626 - SIP Threshold Level Critical
This message indicates that there is a Congestion Level of Critical based on thethreshold set in TH-ALM table for the SIP card.
Example
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890 0002.0626 SIP SYSTEM SIP Threshold Level Critical
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. Use rept-stat-sip command to determine the status of the SIP SYSTEM. If theTPS is beyond the allowed limit, decrease the TPS.
2. Follow the procedures to add more SIP cards to handle the increased SIP traffic.
0627 - SFLOG SYSTEM is not available
This message indicates the system has no SFLOG card that is Active/IS_NR status.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 *C yyyy.0627 *C SFLOG SYSTEM SFLOG SYSTEM is not available
Alarm Level: Critical.
Recovery
Activate (Active/IS-NR) any one of the SFLOG card in the system.
0628 - SFLOG SYSTEM is available
This message indicates the system has at least one SFLOG card that is Active/IS_NRstatus.
UAMs
3-178 EAGLE Unsolicited Alarm and Information Messages Reference
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 yyyy.0628 SFLOG SYSTEM SFLOG SYSTEM is available
Alarm Level: Normal.
Recovery
No further action necessary.
0629 - SFLOG SYSTEM is removed
This message indicates that all SFLOG cards are deleted from the system.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 yyyy.0629 SFLOG SYSTEM SFLOG SYSTEM is removed
Alarm Level: Normal.
Recovery
No further action necessary.
0630 - Throttle Threshold - exceeded
This message indicates the Throttle threshold for a particular Throttling GTT Actionhas exceeded. Any new messages hitting this Throttling Action will be discarded forthe remaining duration of the current 30-second window. This alarm is issued for eachThrottling Action for which the threshold has exceeded.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 ** yyyy.0630 ** TA – abc Throttle Threshold – exceeded
Alarm Level: Major.
Recovery
Review and modify the throttle threshold for the Throttle GTT action if it is notcurrently set appropriately to handle the desired traffic volume.
1. Use the rept-stat-sfthrot command to verify the Throttle Action status.
2. Use the rtrv-gttact and chg-gttact commands to review and modify theThrottle Action settings.
0631 - Throttle Threshold - cleared
This message indicates the Throttle threshold for a particular Throttling GTT Action,or alarm threshold for UAM 0632, has cleared.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 yyyy.0631 TA – abc Throttle Threshold - cleared
UAMs
UAM and UIM Troubleshooting Procedures 3-179
Alarm Level: Normal.
Recovery
No further action necessary.
0632 - Alarm Threshold - exceeded
This message indicates the system wide alarm threshold for the throttling GTT Actionhas exceeded.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 * yyyy.0632 * SCCP SYSTEM Alarm Threshold – exceeded
Alarm Level: Minor.
Recovery
1. Use the rept-stat-sfthrot command to verify the number of MSUs currentlyreceived by the throttling GTT Action in the 30-second window.
Example of the output:
Command Accepted - Processing tklc1181001 16-01-08 05:40:53 MST EAGLE5 46.3.0.0.0-68.8.0 rept-stat-sfthrot Command entered at terminal #3.; tklc1181001 16-01-08 05:40:53 MST EAGLE5 46.3.0.0.0-68.8.0
SCCP Cards Configured= 5 Cards IS-NR= 5 Average CPU Usage = 5%
CARD VERSION PST SST AST TPS
-------------------------------------------------------------------------- 2201 138-008-000 IS-NR Active ----- 0 2213 138-008-000 IS-NR Active ----- 0 2217 P 138-008-000 IS-NR Active ----- 0 2317 138-008-000 IS-NR Active ----- 0 1111 138-008-000 IS-NR Active ----- 116
PER TA TPS STATISTICS:
========================================================================== CURRENT 30 SECS PREVIOUS 30 SECS ---------------------- ---------------------- TA STATUS SUCCESS DISCARD SUCCESS DISCARD -------------------------------------------------------------------------- throt1 ALLOWED 0 0 0 0 throt2 ALLOWED 0 0 0 0
Command Completed.;
UAMs
3-180 EAGLE Unsolicited Alarm and Information Messages Reference
2. Use the rtrv-gttact command to display throttle threshold (THRESHOLD)configured for the throttling GTT Action.
3. Use the rtrv-th-alm command to display the system wide alarm thresholdpercentage (SFTHROTTHRESH) configured for throttling GTT Actions.
4. No action is required if the throttle threshold for the throttling GTT Action andsystem wide alarm threshold percentage for throttling GTT Actions are configuredas necessary.
5. Use the chg-gttact command to update the throttle threshold if the throttlethreshold currently configured for the throttling GTT Action is not adequate.
6. Use the chg-th-alm command to update the system wide alarm thresholdpercentage for throttling GTT Actions, if a higher alarm threshold percentage needsto be set.
0633 - Alarm Threshold - cleared
This message indicates the system wide alarm threshold has cleared.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 yyyy.0633 SCCP SYSTEM Alarm Threshold - cleared
Alarm Level: Normal.
Recovery
No further action necessary.
0901 - Card DB load timeout, check GLS SS
This message indicates that the database of a card or subsystem has been in atransition for 9 minutes. This alarm shows the unavailability of the GLS subsystem. Ifthe Integrated GLS feature is OFF or not yet enabled, this alarm shows that noTSM/E5-TSM is in IS-NR state or no TSM/E5-TSM card is responding to GWSrequests. If the Integrated GLS feature is ON, this alarm shows that the E5-OAM cardsare not performing the GLS functionality properly.
Example
tekelecstp 02-09-21 17:09:58 EST EAGLE5 42.0.2-63.38.33** 0076.0901 ** CARD 1201 SS7ANSI Card DB load timeout, check GLS SS
Alarm Level: Major
Recovery
1. Use the rtrv-ctrl-feat command to check the state of Integrated GLS feature.If the Integrated GLS feature is enabled and ON, the GLS subsystem is running. Goto step 6.
2. If the Integrated GLS feature is OFF or not yet enabled, the GLS subsystem is acollection of TSM/E5-TSM cards running the GLS application. Verify that at leastone TSM/E5-TSM card is in IS-NR state using the rept-stat-card:appl=glscommand.
UAMs
UAM and UIM Troubleshooting Procedures 3-181
3. If TSM/E5-TSM card(s) are not in IS-NR state, enter the init-card:appl=glscommand to boot the GLS subsystem.
4. Verify that the cards come back in service. Use the rept-stat-card:appl=glscommand.
5.Run the rept-stat-db:display=all command to identify which cards are intransition, and note all cards that are in transition state (T column set to "Y"). If thetransition is not cleared, turn the Integrated GLS feature ON again, then contact the My Oracle Support (MOS).
Example of rept-stat-db command:
tekelecstp 02-09-21 16:01:58 EST EAGLE5 42.0.2-63.38.33 DATABASE STATUS: >> NOT OK (DMS) << TDM 1114 ( STDBY) TDM 1116 ( ACTV ) C LEVEL TIME LAST BACKUP C LEVEL TIME LAST BACKUP - -------- ---------------------- - -------- ---------------------- FD BKUP Y 22 02-09-07 13:33:18 EST Y 1 - - FD CRNT Y 71 Y 71 MCAP 1113 MCAP 1115 - -------- - -------- RD BKUP - - - - - - - - USB BKP - - - - - - - -
CARD/APPL LOC C T LEVEL TIME LAST UPDATE EXCEPTION --------- ---- - - ---------- ----------------- -------------- VSCCP 1101 Y N 71 02-09-20 13:25:06 - MCP 1104 - - - - - - CCS7ITU 1105 Y N 71 02-09-20 13:25:06 - MCP 1107 - - - - - - VSCCP 1111 Y N 71 02-09-20 13:25:06 - OAM-RMV 1113 - - - - - - TDM-CRNT 1114 Y N 71 02-09-20 13:25:06 - TDM-BKUP 1114 Y - 22 02-08-31 10:31:00 DIFF LEVEL OAM-RMV 1115 - - - - - - OAM-USB 1115 - - - - - - TDM-CRNT 1116 Y N 71 02-09-20 13:25:06 - TDM-BKUP 1116 Y - 1 00-00-00 00:00:00 DIFF LEVEL
6. If the Integrated GLS feature is ON, turn it OFF with the CHG-CTRL-FEAT:partnum=893038901:status=OFF command.
7. Wait for 5 minutes, and use the rept-stat-db:display=all command toverify that there are no cards in transition. Turn the Integrated GLS feature back onusing the CHG-CTRL-FEAT:partnum=893038901:status=ON command.
8. If the problem persists, contact the My Oracle Support (MOS).
0903 - IP Link A is down
This message indicates that an IP application socket is out of service due to a IP linkdown (ethernet problem) or due to the signaling link being deactivated.
Example
RLGHNCXA03W 01-01-10 16:28:08 EST EAGLE 35.0.0** 0046.0903 ** CARD 1111 EBDADCM IP Link A is down
UAMs
3-182 EAGLE Unsolicited Alarm and Information Messages Reference
Alarm Level: Major
Recovery
1. Enter the following command to determine the IP address of the link:
rtrv-ip-lnk:loc=xxxx:port=a
Where xxxx is the card identified in the alarm output.
2. Enter the following command to retrieve the name of the local host:
rtrv-ip-host:ipadr=xxxx.xxxx.xxxx.xxxx
Where xxxx.xxxx.xxxx.xxxx = the link IP address from 1.
3. Enter the following command to get the name of the remote host:
rtrv-appl-sock:lhost=xxxxxxxx
Where xxxxxxxx = local host name from 2.
4. Enter the following command to test the TCP/IP connection:
pass:loc=xxxx:cmd=”ping yyyyyyyyyy”
Where: xxxx = Card location from the alarm output. yyyyyyyyyy = logical name ofthe remote host from 3.
5. If the ping command fails, perform the following checks:
a. Check the remote host hardware and software.
b. Use your company procedures to check the network.
c. Check cable connections at the IP7 Secure Gateway and at the remote host.
6. If the UNAVAILREASON still indicates an alignment problem, enter the followingcommand:
rept-stat-slk:loc=xxxx:port=a
Where xxxx is the card identified in the alarm output. If the DCM card is not OOS-MT, proceed to 8.
7. If the DCM card is OOS-MT, do the following, using the rept-stat-cardcommand to check for card IS-NR state after each action:
a. Reinitialize card using the init-card command.
b. Reseat the card.
c. Replace the card.
Refer to the Maintenance manual for card removal/replacement procedures.
8. If the fault is not cleared, contact the My Oracle Support (MOS).
0905 - IP Link B is down
This message indicates that an IP application socket is out of service due to a IP linkdown (ethernet problem) or due to the signaling link being deactivated.
UAMs
UAM and UIM Troubleshooting Procedures 3-183
Example
RLGHNCXA03W 01-01-10 16:28:08 EST EAGLE 35.0.0** 0046.0905 ** CARD 1111 EBDADCM IP Link B is down
Alarm Level: Major
Recovery
1. Enter the following command to determine the IP address of the link:
rtrv-ip-lnk:loc=xxxx:port=b
Where xxxx is the card identified in the alarm output.
2. Enter the following command to retrieve the name of the local host:
rtrv-ip-host:ipadr=xxxx.xxxx.xxxx.xxxx
Where xxxx.xxxx.xxxx.xxxx = the link IP address from 1.
3. Enter the following command to get the name of the remote host:
rtrv-appl-sock:lhost=xxxxxxxx
Where xxxxxxxx = local host name from 2.
4. Enter the following command to test the TCP/IP connection:
pass:loc=xxxx:cmd=”ping yyyyyyyyyy”
Where: xxxx = Card location from the alarm output. yyyyyyyyyy = logical name ofthe remote host from 3.
5. If the ping command fails, perform the following checks:
• Check the remote host hardware and software.
• Use your company procedures to check the network.
• Check cable connections at the IP7 Secure Gateway and at the remote host.
6. If the UNAVAILREASON still indicates an alignment problem, enter the followingcommand:
rept-stat-slk:loc=xxxx:port=b
Where xxxx is the card identified in the alarm output. If the DCM card is not OOS-MT, proceed to 8.
7. If the DCM card is OOS-MT, do the following, using the rept-stat-cardcommand to check for card IS-NR state after each action:
• Reinitialize card using the init-card command
• Reseat the card
• Replace the card
Refer to the Maintenance manual for card removal/replacement procedures.
8. If the fault is not cleared, contact the My Oracle Support (MOS).
UAMs
3-184 EAGLE Unsolicited Alarm and Information Messages Reference
0908 - HW cannot support purchased TPS rate
This message indicates that the purchased transactions per second (TPS) rate runningon the DCM(s) is higher than can be supported by you current hardware.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 5.0.0-32.0.0 ** 0100.0908 ** CARD 1101 SS7IPGW HW cannot support purchased TPS rate ASSY SN: 102199815a1234
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 5.0.0-32.0.0
** 0100.0908 ** CARD 1101 SS7IPGW HW cannot support purchased TPS rate
ASSY SN: 102199815a1234
Alarm Level: Major
Recovery
1. Upgrade your DCM hardware.
This alarm can be cleared only when the concerned DCM hardware is unplugged.
2. Contact the My Oracle Support (MOS), for information about upgrading yourDCM hardware.
0911 - Dynamic database is inconsistent
The dynamic database (DDB) audit (whether running automatically or on-demand)has detected that checksums are inconsistent. This means that one or more cards donot concur with the current network configuration. (The UIM lists a maximum of fouraffected cards.)
The dynamic database audit looks for checksum errors in dynamic database tables onLIM and Service Module cards. The fixed database, which is entered via the OAMcard, includes all provisionable tables and options. The dynamic database hasinformation about the state of those static-database entries (for example, which linksare actually available). Each LIM and Service Module card has a copy of the fixeddatabase and the dynamic database. The entries in the tables in the dynamic databaseon each card change as network conditions change. Cards calculate and recorddynamic database checksums in real time as updates are applied.
If the dynamic database is being updated during the dynamic database audit, then theinconsistent checksums might not indicate a true problem. To ensure that all dynamicdatabase changes have been received and applied, the OAM processes audit repliesafter a required quiet period.
Note:
You can use the “DDBAUDTIMER” SS7OPTS option to enable and disable thebackground audit.
Typically, when the dynamic database copies are consistent among all the cards exceptone, then there is a problem on that one card. It is possible, however, for one card tohave the correct information when the other cards do not (for example, a card mighthave a link on it that is actually available when the other cards incorrectly show the
UAMs
UAM and UIM Troubleshooting Procedures 3-185
link as unavailable). When this alarm occurs, further troubleshooting is necessary todetermine the actual status of the routes, links, linksets, and subsystems.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 41.0** 0100.0911 ** SYSTEM Dynamic database is inconsistent Card 1101, 1102, 1107, 1108, ... (3 others)
Alarm Level: Major
Recovery
The Eagle cannot automatically determine which cards are inconsistent. Do thefollowing to address a dynamic-database inconsistency alarm:
1. Run the rept-stat-ddb command to display the last dynamic database auditreport.
2. Initialize the affected cards identified in the dynamic database audit report:
a. If a small number of cards are reported inconsistent, initialize them using theinit-card:loc= command. You should initialize the affected cardsimmediately.
b. If all cards of the same type report inconsistencies, initialize them using theinit-card:appl=command.
Caution: This command could affect service as it will boot all the appl cardsat the same time (for example, the command could cause loss of SCCP if theinit-card:appl=VSCCPcommand is run).
3. Run the rept-stat-card:mode=full:loc= command on each card identifiedas inconsistent to verify the card is IS-NR.
4. If a large number of cards of various types report inconsistent, you might need toissue the init-network or the init-sys command to clear the inconsistency.
Caution: These commandswill cause a nodal outage.
5. After the cards are initialized, run the aud-data:type=DDB command. If thereport shows no inconsistency, then the problem is fixed.
6. Next, you can use the dbg-ddb command to troubleshoot the problem. Theparameters to use in the dbg-ddb command depend on the type of dynamicdatabase update that was missed (route/link/linkset).
When a system reports dynamic database inconsistencies, first check the IMT busesstatistics to make sure they are clean. This is important because multicast updatesresulting from network activity transit via the IMT buses and any outstanding issueon this part of the system may lead some cards to miss the updates and OAM toreport dynamic database inconsistencies. When a checksum is identified to beincorrect and is updated by a wild write audit, you may want to know that adynamic database inconsistency reported on a card was due to a wild write (ratherthan any other cause, such as a missed multicast). In the scenario where one or agroup of cards miss a dynamic database update related to a network state change,then the counter collecting the total number of update misses is incremented. Usethe dbg-ddb command to retrieve this counter.
UAMs
3-186 EAGLE Unsolicited Alarm and Information Messages Reference
7. Contact the My Oracle Support (MOS).
UIMsThe following are UIMs that may be displayed.
1000 - MTP rcvd UPU - user part is not SCCP
The system forwarded a unit data (UDT) message to a distant node that does notsupport SCCP. In response, the distant node sent back a user part unavailable (UPU)message.
The message provides the affected point code (which sent the UPU), as well as theservice information octet (SIO) field of the message and the cause code.
All fields are in decimal values. The SIO field values applicable to this message are:
03 – SCCP
04 – Telephone User Part (TUP)
05 – ISDN User Part (ISUP)
06 – Data User Part (call and circuit related messages)
07 – Data User Part (facility registration and cancellation)
08 – MTP Testing User Part
The message also provides the value for the User Part that was unavailable (UPU=).The values shown above apply to this field as well.
The Cause Codes (Unavail Cause =) applicable to this message are:
000 – Unknown
001 – Unequipped Remote User
002 – Inaccessible User Part
Unequipped remote user indicates the distant node is not equipped for SCCP.Inaccessible user part indicates that the distant node is equipped with SCCPcapability, but there has been a failure in SCCP making it impossible to handlemessages sent to it by MTP.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0 0100.1000 CARD 1201,A INFO MTP rcvd UPU - user part is not SCCPSIO=03 OPC=003-232-000 DPC=001-004-000 AFTPC=004-000-001 UPU=03 UNAVAIL CAUSE=001 LSN=A1234567
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1020 - IARCDPN NPP Service is off
This message is issued when the IARCDPN NPP service is called for at run-time, butthe service status is currently set to OFF instead of ON.
Example
UIMs
UAM and UIM Troubleshooting Procedures 3-187
RLGHNCXA21W 09-07-21 16:20:19 EST EAGLE 41.1.0 0002.1020 CARD 1113 INFO IARCDPN NPP Service is off Report Date:09-07-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
Use the chg-npp-serv command to change the service status to ON. Enter chg-npp-serv:srvn=iarcdpn:status=on.
1021 - IARCGPN NPP Service is off
This message is issued when the IARCGPN NPP service is called for at run-time, butthe service status is currently set to OFF instead of ON.
Example
RLGHNCXA21W 09-07-21 16:20:19 EST EAGLE 41.1.0 0002.1021 CARD 1113 INFO IARCGPN NPP Service is off Report Date:09-07-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
Use the chg-npp-serv command to change the service status to ON. Enter chg-npp-serv:srvn=iarcgpn:status=on.
1022 - System Meas. limit exceeded for LSONISMT
This UIM alarm is issued when the either of these limits is exceeded:
• Maximum of 3000 LSONISMT measurements, or
• Maximum of 100 ISUP message type measurements per linkset.
Example
RLGHNCXA21W 00-04-18 19:09:14 EST EAGLE 31.3.00140.1022 SYSTEM INFO System Meas. limit exceeded for LSONISMT
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. Each link in a linkset collects measurements for 100 ISUP message typemeasurements.
Only the first 100 types collected per linkset are reported. Those links that are notreported in the LSONISMT Report have their counts added to the totals in theLSORIGNI Gateway Report and the STP Report (MSUDSCRD field).
2. If the system total exceeds 3000, only the first 3000 collected are reported in theLSONISMT Gateway Report.
Any counts not included in this report are added to the totals in the LSORIGNIGateway Report and the STP Report (MSUDSCRD field).
UIMs
3-188 EAGLE Unsolicited Alarm and Information Messages Reference
1026 - System Meas Limit exceeded for LSORIGNI
This gateway related data has exceeded its threshold for the accumulation interval.
Example
RLGHNCXA21W 00-04-18 19:05:43 EST EAGLE 31.3.00128.1026 CARD 1105 INFO System Meas Limit exceeded for LSORGNI
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1027 - System Meas Limit exceeded for LSDESTNI
This gateway related data has exceeded its threshold for the accumulation interval.
Example
RLGHNCXA21W 00-04-18 19:05:43 EST EAGLE 31.3.00128.1027 CARD 1105 INFO System Meas Limit exceeded for LSDESTNI
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1028 - System Meas. Limit exceeded for ORIGNI/NINC
This gateway related data has exceeded its threshold for the accumulation interval.
Example
RLGHNCXA21W 00-04-18 19:05:43 EST EAGLE 31.3.00128.1028 CARD 1105 INFO System Meas. Limit exceeded for ORIGNI/NINC
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1030 - Inh EIR SS request already outstanding
An inh-map-ss command is already entered and queued.
For more information about the inh-map-ss command, refer to the CommandsManual.
Example
RLGHNCXA21W 03-08-18 19:09:14 EST EAGLE 31.3.00140.1030 CARD 1201 INFO Inh EIR SS request already outstanding
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
UIMs
UAM and UIM Troubleshooting Procedures 3-189
1031 - Failure Inhibiting EIR SS
The inh-map-ss command was unsuccessful in taking the EIR subsystem off-line.For more information about the inh-map-ss command, refer to the CommandsManual.
Example
RLGHNCXA21W 03-08-18 19:09:14 EST EAGLE 31.3.00140.1031 CARD 1201 INFO Failure Inhibiting EIR SS
Alarm Level: No alarm condition. The message is informational only.
Recovery
Enter the inh-map-ss command specifying the force=yes parameter.
1032 - Set ETS Mismatch
There is a discontinuity between the ETS broadcast and what the card expects. Adiscontinuity can occur when both OAM cards are booted at the same time and ETSgets reset to zero.
Example
RLGHNCXA21W 03-08-18 19:09:14 EST EAGLE 31.3.00140.1032 CARD 1201 INFO Set ETS Mismatch
Alarm Level: No alarm condition. The message is informational only.
Recovery
The affected LIM/ATM/STC card recalibrates to the new ETS value and shouldcontinue to operate correctly.
If not, this is a reference point for possible invalid timestamps to Sentinel.
1061 - Meas sync not allowed from old version
This UIM is generated when the secondary MCP receives measurements data from aprimary MCP that is running an older version of the software. This message indicatesthat measurements data was discarded by the secondary MCP due to the versionmismatch. This problem occurs during a system upgrade to a new release.
Example
RLGHNCXA21W 00-04-18 19:09:14 EST EAGLE 31.4.00140.1061 CARD 1201 INFO Meas sync not allowed from old version
Alarm Level: No alarm condition. The message is informational only.
Recovery
This UIM should only occur during an upgrade.
Complete the upgrade per approved procedure.
1062 - String Data Dump
A screen set was created with too many rows.
Example
UIMs
3-190 EAGLE Unsolicited Alarm and Information Messages Reference
12345678901234567890123456789012345678901234567890123456789012345678901234567890 9912.1062 CARD 1113 INFO a50 too large Report Date:14-08-01 Time:13:32:14
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. This message indicates that the screen set is too large to be loaded.
Remove some of the entries (one entry at a time).
2. If the screen set is still too large, use the rtrv-scrset command to see if there areany unnecessary entries already in the screen set that can be deleted.
3. Retry adding to the screen set with the chg-scrset command.
If the message appears again, your screen set is too large. Try a different screen setor change the existing screen set.
1063 - SCCP screen set is too large
The screen set is too large to fit on a LIM or SCCP card and has failed loading.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 5946.1063 CARD 1113 INFO SCCP screen set is too large Report Date:14-08-02 Time:17:01:45
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. This message indicates that the screen set is too large to be loaded to a LIM orSCCP.
Remove some of the entries (one entry at a time).
2. If the screen set is still too large, use the rtrv-scrset command to see if there areany unnecessary entries already in the screen set that can be deleted.
3. Retry adding to the screen set with the chg-scrset command.
If the message appears again, your screen set is too large. Try a different screen setor change the existing screen set.
1072 - SLTC failure: no response
The signaling link test control has reported “No Response” received for a signalinglink test message (SLTM) sent to the far end.
Example
tekelecstp 13-07-11 06:06:31 EST EAGLE5 44.0.4-64.34.24 5757.1072 CARD 4205,B1 INFO SLTC failure: no response
Alarm Level: No alarm condition. The message is informational only.
Recovery
Contact the far-end to find out why there is no response to the SLTM.
UIMs
UAM and UIM Troubleshooting Procedures 3-191
1075 - MTP: link bypassed SLT phase
The link has aligned and may be brought into service without a successful signalinglink test (SLT).
Example
RLGHNCXA21W 00-04-18 19:09:14 EST EAGLE 31.3.00140.1075 CARD 1201,A INFO MTP: link bypassed SLT phase
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. Enter the rtrv-slk command with the card location and port shown in thismessage (for example, card location 1201, port A).
Example of the output:
tekelecstp 00-02-19 21:17:04 EST EAGLE 35.0.0rtrv-slk:loc = 1202:port = aCommand entered at terminal #3. tekelecstp 94-02-19 21:17:04 EST EAGLE 35.0.0 L2T L1 PCR PCRLOC PORT LSN SLC TYPE SET BPS MODE TSET ECM N1 N21201 A lsa1 0 LIMV35 2 64000 DTE --- PCR --- 3800
2. Use the rtrv-ls command using the linkset name (lsn) displayed in the output of 1.
Example of the output:
> rtrv-ls:lsn = lsa1tekelecstp 00-06-10 11:43:04 EST EAGLE 35.0.0 SCR L3T SLT LSN APCA (SS7) SET SET SET BEI LST LNKS GWSA GWSM GWSD DOMAIN lsa1 240-020-000 scr1 1 1 yes A 4 off off off SS7 TFATCABMLQ 2 L2T L1 PCR PCR LOC PORT SLC TYPE SET BPS MODE TSET ECM N1 N2 1201 a 3 LIMV35 2 64000 DTE --- BASIC --- ----- 1205 b 0 LIMDS0 1 56000 --- --- BASIC --- ----- b 1 LIMOCU 1 56000 --- --- BASIC --- ----- 1211 a 2 LIMDS0 1 56000 --- --- BASIC --- ----- Link set table is (114 of 255) 45% full.
3. Enter the rtrv-slt command with the sltset parameter and the value shown inthe SLTSET column from the output of Step 2 to determine whether the signalinglink test message is on or off.
4. If the signaling link test message is off, enter the chg-slt command with the sltsetparameter and the value used in Step 3, and the enabled=on parameter.
5. If the signaling link test message is on, enter the rept-stat-card command toverify the status of the card that contains the specified signaling link.
The status of the card should be IS-NR (In-Service - Normal).
UIMs
3-192 EAGLE Unsolicited Alarm and Information Messages Reference
6. If the card is out of service, put it back into service by entering the rst-cardcommand.
7. If the fault is not cleared, enter the rept-stat-slk command to verify the statusof the signaling link.
The status of the signaling should be IS-NR (In-Service - Normal).
8. If the signaling link is out of service, enter the act-slk command to put thesignaling link back into service.
9. If the fault is not cleared, enter the tst-slk command specifying the signalinglink that generated this message.
10. If the fault is not cleared, contact the My Oracle Support (MOS).
1080 - disk measurement status unreadable
The active MASP could not determine the measurement collection status so that themeasurements task could perform routine polling and measurement collection. If themeasurement collection status cannot be determined, the routine polling andmeasurement collection tasks cannot be performed.
Example
RLGHNCXA21W 00-04-18 19:10:54 EST EAGLE 31.3.00145.1080 CARD 1116 INFO disk measurement status unreadable
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. Enter the rept-meas command.
If the rept-meas command fails, a system problem is the likely cause.
a. If any messages are generated with the rept-meas command failure, take theappropriate action for that message.
b. If no messages are generated, contact the My Oracle Support (MOS).
2. If the rept-meas command is rejected with a system busy message, the disk isreserved by another command (for example, copy-disk).
Check to see if another command is running (copy-disk or a chg-db command).
1081 - MTP: Changeback T5 timeout
When a link changes back, the EAGLE 5 ISS sends up to six changeback declarationmessages and starts the T4 timer. The EAGLE 5 ISS waits for a changebackacknowledgment message for each of these declarations. If the T4 timer expires beforethe EAGLE 5 ISS receives an acknowledgment message, the EAGLE 5 ISS sends thechangeback declaration message again and starts the T5 timer. If the T5 timer expiresbefore the EAGLE 5 ISS receives an acknowledgment message, this message isgenerated and the EAGLE 5 ISS restarts traffic on the link.
Example
RLGHNCXA21W 00-04-18 19:11:03 EST EAGLE 31.3.00146.1081 CARD 1105, A INFO MTP: Changeback T5 timeout
UIMs
UAM and UIM Troubleshooting Procedures 3-193
Alarm Level: No alarm condition. The message is informational only.
Recovery
The system restarts traffic and no further action is necessary.
1082 - Amem single bit error report
This message indicates that an SCCP, GLSHC, SIP or S13 (DEIR) card encountered asingle bit dynamic ram error. This message gives the user a record of single bit errorsfor the last 24 hours.
Example
RLGHNCXA21W 14-05-18 19:12:00 EST EAGLE 46.0.00147.1082 CARD 1101 INFO Amem single bit error reportAny Errors : YES current hour-------v24 Hour History : NNNYNN NNNNNN NNNNYN NYNNNY
Alarm Level: No alarm condition. The message is informational only.
Recovery
There is no immediate action needed, but the message indicates that the error wasencountered and corrected.
If many errors are reported then the card may be beginning to fail and should betargeted for replacement in the future.
1083 - REPT COND: system alive
This message is a periodic system message indicating that the system is alive.
Example
RLGHNCXA21W 00-04-18 19:12:00 EST EAGLE 31.3.00147.1083 SYSTEM INFO REPT COND: system alive
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1086 - LFS test aborted with OAM switchover
The link fault sectionalization (LFS) test aborted with OAM switch over.
Example
RLGHNCXA21W 14-05-18 19:11:03 EST EAGLE 46.0.01111.1086 CARD 1115 LFS test terminated with OAM switch over
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1087 - MTP RSTRT rcvd unexpected user traffic
This message indicates the system encountered traffic during the MTP Restart process.
UIMs
3-194 EAGLE Unsolicited Alarm and Information Messages Reference
Example
RLGHNCXA21W 00-04-18 19:12:00 EST EAGLE 31.3.00147.1087 CARD 1101 INFO MTP RSTRT rcvd unexpected user trafficReport Date:00-03-30 Time: 16:27:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
There is no immediate action needed, but the message indicates that the error wasencountered.
1088 - REPT-MTP-RSTRT MTP Restart started
This message indicates that a full MTP Restart has begun.
Example
RLGHNCXA21W 00-04-18 19:12:00 EST EAGLE 31.3.00147.1088 CARD 1101 INFO REPT-MTP-RSTRT MTP Restart startedReport Date:00-03-30 Time: 16:27:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
There is no immediate action needed, but the message indicates that MTP Restart hasbegun.
1089 - RCVRY-MTP-RSTRT MTP Restart completed
This message indicates a full MTP Restart is complete.
Example
RLGHNCXA21W 00-04-18 19:12:00 EST EAGLE 31.3.0
0147.1089 CARD 1101 INFO RCVRY-MTP-RSTRT MTP Restart completed
Report Date:00-03-30 Time: 16:27:19 :
Alarm Level: No alarm condition. The message is informational only.
Recovery
There is no immediate action needed, but the message indicates that MTP Restart iscomplete.
1095 - ITU GWY:GRS buffer full
This message indicates the circuit group reset (GRS) buffer is full.
Example
station5 00-04-18 19:12:00 EST EAGLE 31.3.00110.1095 CARD 1205,B INFO ITU GWY:GRS buffer full
Alarm Level: No alarm condition. The message is informational only.
Recovery
There is no immediate action needed, but the message indicates that the error wasencountered.
UIMs
UAM and UIM Troubleshooting Procedures 3-195
1096 - ITU GWY:RSC buffer full
This message indicates the reset circuit (RSC) buffer is full.
Example
station5 00-04-18 19:12:00 EST EAGLE 31.3.00110.1096 CARD 1205,B INFO ITU GWY: RSC buffer full
Alarm Level: No alarm condition. The message is informational only.
Recovery
There is no immediate action needed, but the message indicates that the error wasencountered.
1097 - ITU GWY:CGB buffer full
This message indicates the circuit group blocking (CGB) buffer is full.
Example
station5 00-04-18 19:12:00 EST EAGLE 31.3.00110.1097 CARD 1205,B INFO ITU GWY: CGB buffer full
Alarm Level: No alarm condition. The message is informational only.
Recovery
There is no immediate action needed, but the message indicates that the error wasencountered.
1098 - Unexpected disk access timeout
This message is used to determine whether there are problems with the disk accesssystem.
Example
station5 00-04-18 19:12:00 EST EAGLE 31.3.00110.1098 CARD 1113 INFO Unexpected disk access timeout
Alarm Level: No alarm condition. The message is informational only.
Recovery
If the target disk is the same CARD that corresponds to the GPSM-II, there is asoftware timing issue that needs to be addressed.
If the target disk is the mate GPSM-II/TDM or the removable and access is physicallyimpossible, no action is necessary.
1099 - String Data Dump
This is a generic UIM. The informational message in the UIM varies.
Example
FTP Transfer Failed due to network congestion
Alarm Level: No alarm condition. The message is informational only.
UIMs
3-196 EAGLE Unsolicited Alarm and Information Messages Reference
Recovery
No action is necessary.
1101 - SDRAM Single Bit Error Report
This message indicates SDRAM memory on HIPR (or IMTPCI) is detecting Single BitErrors (SBEs). This may be an indication that the card should be replaced (memorybecoming faulty) before Multi Bit Errors (MBEs) begin to occur, which results in anOBIT of the card.
Example
RLGHNCXA21W 02-07-21 16:20:19 EST EAGLE 35.0 0024.1101 CARD 1109 INFO SDRAM single bit error report Any Errors : YES current hour------v 24 Hour History : NNNYNN NNNNNN NNNNYN NYNNNY Microengine Count : 12345678 PCI Count : 12345678 StrongARM Count : 12345678 Report Date:02-07-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
The card generating the error may need replacement. Refer to the Maintenance manualfor card removal/replacement procedures. Contact the My Oracle Support (MOS).
1104 - IP Connection Failed
Reports that either an attempt to connect to an IP server failed, or that a client socketfailed to establish a connection with the system (IP7 Secure Gateway).
Example
RLGHNCXA03W 99-04-10 16:28:08 EST EAGLE 35.0.00003.1104 DCM 1213,A IP Connection Failed RIPADDR = 123.123.123.123 RPORT = 1314 LIPADDR = 123.123.123.124 LPORT = 1315 SNAME=LONGSOCKETNAME1 Report Date: 02-04-10 Time: 16:27:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
Reports on connection status can be obtained for each DCM card with the followingcommands:
pass:loc=xxxx:cmd=”connmgr -l” displays the connection manager eventlog.pass:loc=xxxx:cmd=”connmgr -c” displays socket client data.pass:loc=xxxx:cmd=”connmgr -s” displays socket server data.
UIMs
UAM and UIM Troubleshooting Procedures 3-197
1105 - REPT EVT:IMT GPL reloading
This message indicates the IMT software download procedure is initiated. This is thefirst message that the system displays.
Example
RLGHNCXA21W 00-04-18 18:59:58 EST EAGLE 31.3.00105.1105 SYSTEM INFO REPT EVT:IMT GPL reloading cards loaded : 1 of 25
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1106 - REPT COND:IMT GPL reloading
This message displays the progress of the IMT software downloading procedure.
Example
RLGHNCXA21W 00-04-18 18:59:58 EST EAGLE 31.3.00105.1106 SYSTEM INFO REPT COND:IMT GPL reloading cards loaded : 10 of 25
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1114 - Database BACKUP started
A local database backup is beginning. This UIM follows the issue of the chg-db:action=backup command.
Example
RLGHNCXA21W 00-06-18 19:12:00 EST EAGLE 31.3.00147.1114 CARD 1201,A INFO Database BACKUP started
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1115 - Database RESTORE started
A local database restore is beginning. This UIM follows the issue of the chg-db:action=restore command.
Example
RLGHNCXA21W 00-06-18 19:12:00 EST EAGLE 31.3.00147.1115 CARD 1201,A INFO Database RESTORE started
Alarm Level: No alarm condition. The message is informational only.
Recovery
UIMs
3-198 EAGLE Unsolicited Alarm and Information Messages Reference
No action is necessary.
1116 - Database action ended - OK
A local database backup or restore has successfully completed. This UIM follows theissue of the chg-db command.
Example
RLGHNCXA21W 00-06-18 19:12:00 EST EAGLE 31.3.00147.1116 CARD 1201,A INFO Database action ended - OK
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1117 - Database action ended - FAIL
This error message indicates that one or more cards specified in the init-flash/act-flash command is out of phase with the command.
Example
RLGHNCXA21W 00-06-18 19:12:00 EST EAGLE 31.3.00147.1117 CARD 1201,A INFO Database action ended - FAILED
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1118 - TOD change affects MEAS collection
This message indicates that due to a time change, the measurements in a specificperiod may be inaccurate.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 0020.1118 CARD 1106 INFO TOD change affects MEAS collection Report Date:02-07-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1119 - Cards out of phase with flash procedure
This message indicates that the collection sequence has been disrupted and the 60-minute and/or 30-minute data may be inaccurate.
Example
123456789012345678901234567890123456789012345678901234567890123456789012345678900020.1119 CARD 1115 INFO Cards out of phase with flash procedure Card List: 1101, 1201, 1302, 2103, 2204, ... (2 others) Report Date:02-07-21 Time:16:20:19
UIMs
UAM and UIM Troubleshooting Procedures 3-199
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1120 - TRBL Queue is full:elements overwritten
This message indicates that too many UIMs per second are being output. One or moremight be lost.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1120 CARD 1113 INFO RBL Queue is full;elements overwritten
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1124 - SIP: Dgts truncated in 302 response
SIP 302 response shall encode only 30 digits in dialed string/telephone number and 25digits in RN. The remaining digits shall be truncated.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 0014.1124 CARD 1103,B INFO Dgts truncated in 302 response CNAME= conn1 Branch ID = z9hG4bKnashds8 RURI: INVITE sip:+1 206 [email protected]:5070;user=phone
Report Date:10-10-12 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No further action is required.
1132 - SLAN DLK ping test completed
This message indicates that the manual TCP/IP ping test has completed. The ping testis initiated by the tst-dlk command.
Example
RLGHNCXA21W 00-06-18 19:12:00 EST EAGLE 31.3.00147.1132 CARD 1201 INFO SLAN DLK ping test completed.TESTS REQUESTED= 0 PASSED COUNT=0 FAILED COUNT =00AVR RND TRIP=0 MAX RND TRIP=06 MIN RND TRIP=0 HOST IPADDR =194.4.201.50
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. If the test passes with FAILEDCOUNT = 00, no further action is necessary.
UIMs
3-200 EAGLE Unsolicited Alarm and Information Messages Reference
2. If the test fails:
a. confirm that IP addresses are correct
b. confirm with the end user that their equipment and software is up andfunctioning properly
c. have the end user check their network and their cable connections
d. check the cable connections at the EAGLE 5 ISS
e. Contact the My Oracle Support (MOS).
1133 - Diameter msg decode failed
This message indicates that the Diameter message parsing has failed. This may because by:
• ECR Message does not have IMEI AVP or a value in IMEI AVP
• CER Message does not have mandatory AVP present
• DPR message received does not have disconnect cause AVP present
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 xxxx.1133 CARD 1103,B INFO Diameter msg decode failed DCNAME= dcon1 Command Code=(R) AVP Code= Origin Host= host1 Error Cause= avp not present
Alarm Level: No alarm condition. The message is informational only.
1134 - Diameter msg encode Failed
This message indicates that the Diameter message Encoding has failed.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 xxxx.1134 CARD 1101,B INFO Diameter msg encode failed DCNAME=dcon2 Command Code= (A) Origin Host=host1 Error Cause=Invalid IMEI digits
Alarm Level: No alarm condition. The message is informational only.
1135 - Invalid diameter Msg received
This message indicates that the Diameter message received is not supported by theEAGLE.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890
UIMs
UAM and UIM Troubleshooting Procedures 3-201
xxxx.1135 CARD 1101,B INFO Invalid Diameter Msg received DCNAME= dcon1 Command Code= 4022 (R) Origin Host=--- Error Cause=---
Alarm Level: No alarm condition. The message is informational only.
1136 - Invalid Diameter Msg length
This message indicates one of the following conditions:
1. The total Diameter message length specified in the diameter header does notmatch the actual diameter message length.
2. The diameter message length is greater than the maximum length of 448 bytessupported by current EIR S13/S13's implementation.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 xxxx.1136 CARD 1101,B INFO Invalid Diameter Msg length DCNAME= dcon1 Command Code= (R) Origin Host=--- Error Cause=---
Alarm Level: No alarm condition. The message is informational only.
1137 - Diameter AVP Decode Fail
This message indicates an invalid length for the IMEI/IMSI AVP has received.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 xxxx.1137 CARD 1101,B INFO Diameter AVP Decode Fail DCNAME= dcon1 Command Code= (R) AVP Code= Origin Host=--- Error Cause=AVP Decode Error
Alarm Level: No alarm condition. The message is informational only.
1138 - Connection Refused
This message indicates that the Origin host and Origin Realm AVPs in the CERmessage does not match the host and real values provisioned in the IPAPSOCK table.The Source IP Address of the CER does not match the IP Address present in the Host-IP-Address AVP. This may be cause by:
• Origin Host Mismatch
• Origin Realm Mismatch
• IP Address Mismatch
• No common Application
UIMs
3-202 EAGLE Unsolicited Alarm and Information Messages Reference
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 xxxx.1138 CARD 1101,B INFO Connection Refused DCNAME= dcon1 Command Code= (R) Origin Realm=aricent.com Error Cause=Origin Realm Mismatch
Alarm Level: No alarm condition. The message is informational only.
1139 - DEIROPTS: DEIR Global Response is ON
This message indicates that the DEIR Global response is ON.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 6056.1139 CARD 1115 INFO DEIROPTS: DEIR Global Response is ON
Alarm Level: No alarm condition. The message is informational only.
1140 - DEIROPTS: DEIR Global Response is OFF
This message indicates that the DEIR Global response is OFF.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 6056.1140 CARD 1115 INFO DEIROPTS: DEIR Global Response is OFF
Alarm Level: No alarm condition. The message is informational only.
1141 - AIN INP Qry rejected: AINPQ is OFF
The EAGLE 5 ISS has rejected an ANSI INP query that is decoded as an AIN querybecause the appropriate AINPQ (ANSI INP Query) feature key is not on.
Example
6812.1141 CARD 1103 INFO AIN INP Qry rejected: AINPQ is OFF TRANSLATED PC= 001-001-001 TRANSLATED SS=002 CDPA: NI=0 RI=0 GTI=02 SSNI=1 PCI=1 TT=006 NP=-- NAI=--- ADDR=234567 PC= 003-003-001 SSN=002 CGPA: NI=0 RI=1 GTI=00 SSNI=1 PCI=1 PC= 002-002-001 SSN=002 LSN=ls221
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. If you want to support the AINPQ feature, issue the following commands toprocess ANSI AIN queries: enable-ctrl-feat:partnum:893017801:fak=<ANSI-41 INP Query FAK>
2. Enter chg-ctrl-feat:partnum:893017801:status=on command.
UIMs
UAM and UIM Troubleshooting Procedures 3-203
3. If you do not want to support the AINPQ feature, ignore this informationalmessage.
4. For additional information or assistance about the AINPQ or any feature topurchase, contact the My Oracle Support (MOS).
1142 - GWS Strip Stop Action Failed
GWS Strip stop action has failed to de-encapsulate the MSU.
Example
6812.1142 CARD 1103 INFO GWS Strip Stop Action Failed Report Date:13-10-10 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. Send the redirected MSU for the STRIP action to be applied.
2. Verify that the filtering criteria of the 'STRIP' action matches the parametersencoded by REDIRECT stop action.
1143 - GTT(FLOBR) failure: duplicate settype
This message indicates that any one of the MBR GTT Settypes (IMSI\MSISDN\VLRnb\SMRPOA\SMRPDA) is found twice in the FLOBR search path, and the fallback is setto "NO" in the last matched translation. This results in GTT failure.
Example
0018.1143 CARD 1103 INFO GTT(FLOBR) failure: duplicate settype SIO=03 OPC=4-123-5 DPC=6-018-7 CDPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1 TT=25 NP=04 NAI=010 ADDR=123456789012345678901 PC=3-026-5 SSN=005 CGPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1 TT=100 NP=07 NAI=012 ADDR=012345678901234567890 PC=----------- SSN=004 LSN=ls2314n2 GTTSETIDX=211 215
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. Update the FLOBR GTT search path configuration via the chg-gta command sothat the same MBR GTT settype is not encountered in the search path again.
1144 - GTT(FLOBR) warning: duplicate settype
This message indicates that any one of the MBR GTT Settypes (IMSI\MSISDN\VLRnb\SMRPOA\SMRPDA) is found twice in the FLOBR search path, and the fallback is setto "Yes" in the last matched translation. GTT is then performed on the basis of the lastmatched translation. This is a successful scenario.
Example
0028.1144 CARD 1103 INFO GTT(FLOBR) warning: duplicate settype SIO=03 OPC=4-123-5 DPC=6-018-7
UIMs
3-204 EAGLE Unsolicited Alarm and Information Messages Reference
CDPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1 TT=25 NP=04 NAI=010 ADDR=123456789012345678901 PC=3-026-5 SSN=005 CGPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1 TT=100 NP=07 NAI=012 ADDR=012345678901234567890 PC=----------- SSN=004 LSN=ls2314n2 GTTSETIDX=211 215
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. Update the FLOBR GTT search path configuration via the chg-gta command sothat the same MBR GTT settype is not encountered in the search path again.
1145 - MBR decoding failed
This message indicates that there is a problem with decoding the TCAP portion of theincoming MSU. The UIM information displays the error reason and the parametervalue. The GTT will be performed on the basis of the "fallback" value set in the lastmatched translation.
Example
0018.1145 CARD 1103 INFO MBR decoding failed Reason= MSISDN decoding failed (Extension bit is zero) OPC=4-123-5 DPC=6-018-7 CDPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1 TT=25 NP=04 NAI=010 ADDR=123456789012345678901 PC=3-026-5 SSN=005 CGPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1 TT=100 NP=07 NAI=012 ADDR=012345678901234567890 PC=----------- SSN=004 Op-Code=2 PKG-Type= TC BEGIN(0x62) Comp-Type= Invoke(0xA1) MAP PARAM: NP=1 NON=1 Ext-Bit=0 MAP Digits=12345678912
Report Date:15-07-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1146 - REPT-XLST-TIMO: X-LIST entry expired
This message indicates that the timer has expired for an x-list entry and that entry hasbeen removed.
Example
RLGHNCXA21W 00-06-18 19:12:00 EST EAGLE 31.3.00147.1146 CARD 1201 INFO REPT-XLST-TIMO:X-LIST entry expired DPC=001-001-001
Alarm Level: No alarm condition. The message is informational only.
UIMs
UAM and UIM Troubleshooting Procedures 3-205
Recovery
No further action is necessary.
1149 - SLK Level-3 T19 timer expired
The link has been down for 5 minutes or the timer T19 has timed out.
Example
RLGHNCXA21W 00-06-18 19:12:00 EST EAGLE 31.3.00147.1149 CARD 1201,A INFO SLK Level-3 T19 timer expired
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. Activate measurements using the chg-meas:collect=on command.
This starts measurements collection.
2. If the link is placed OOS-MT, use the measurements collected over the appropriatetime period to determine the cause, and determine which action is now necessary.
Note: Refer to the Measurements Manual for traffic measurements information.
1150 - SLK Inhibit Denied
The request to inhibit the link has been denied.
Example
• The following is an example of an error occurring at the near end.
RLGHNCXA21W 03-12-22 21:49:03 EST EAGLE 40.1 7271.1150 CARD 1202,A INFO SLK Inhibit denied Source: Local Reason: Only one link available in the linkset Report Date:03-12-22 Time:21:49:03
• The following is an example of an error occurring at the far end.
RLGHNCXA21W 03-12-22 21:49:03 EST EAGLE 40.1 7271.1150 CARD 1202,A INFO SLK Inhibit denied Source: Remote Reason: Unknown Report Date:03-12-22 Time:21:49:03
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. If denied locally, inhibiting the link would cause the far end to prohibit the pointcode. If remotely denied, contact the far-end office to determine the cause and tocorrect the problem.
UIMs
3-206 EAGLE Unsolicited Alarm and Information Messages Reference
1151 - SLK Inhibit Response Timeout
The system has sent a link inhibit request, but no inhibit acknowledge was received.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1151 CARD 1205,A nc00027 SLK Inhibit Response Timeout
Alarm Level: No alarm condition. The message is informational only.
Recovery
Try the inhibit command again.
If still unsuccessful, contact the far-end office and verify the status.
1152 - SLK Uninhibit Denied
The far end has denied the craftsperson’s request to uninhibit the link.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1152 CARD 1205,A nc00027 SLK Uninhibit Denied
Alarm Level: No alarm condition. The message is informational only.
Recovery
Contact the far end office to determine why this was denied.
1153 - SLK Uninhibit Response Timeout
An uninhibit request was sent, but an uninhibit acknowledge was not received.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1153 CARD 1205,A nc00027 SLK Uninhibit Response Timeout
Alarm Level: No alarm condition. The message is informational only.
Recovery
Try the uninhibit request again.
If still unsuccessful, contact the far-end.
1154 - MSU received threshold exceeded
This UIM is produced by the OAM. It is produced whenever the cumulative count ofMSUs received due to gateway screening on a given linkset exceeds the specified GWSactivity threshold (MSU_recvd_threshold) within a specified time period.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1154 SYSTEM INFO MSU-received threshold exceeded
UIMs
UAM and UIM Troubleshooting Procedures 3-207
Alarm Level: No alarm condition. The message is informational only.
Recovery
No further action is necessary.
1155 - MSU-rejected threshold exceeded
This UIM is produced by the OAM. It is produced whenever the cumulative count ofMSUs discarded due to gateway screening on a given linkset exceeds the specifiedGWS activity threshold (MSU_reject_threshold) within a specified time period.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1155 SYSTEM INFO MSU-rejected threshold exceeded
Alarm Level: No alarm condition. The message is informational only.
Recovery
No further action is necessary.
1156 - Minor congestion event detected
This message is issued when a HIPR2 card detects a minor congestion event. Acongestion event is one 10 millisecond time slice that exceeds the specified busutilization for that time slice on a segment as detected by the HIPR2.
Example
RLGHNCXA21W 09-02-07 12:01:43 EST EAGLE 41.1.0 0023.1156 CARD 1109 INFO Minor congestion event detected Report Date:09-02-07 Time:12:01:43
Alarm Level: No alarm condition. The message is informational only.
Recovery
Although no action is required, the message can serve as a notification that thisparticular section of the IMT bus is reaching its saturation.
Contact the My Oracle Support (MOS) for more information.
1157 - Major congestion event detected
This message is issued whenever a HIPR2 card detects a major congestion event. Acongestion event is one 10 millisecond time slice that exceeds the specified busutilization for that time slice on that segment.
Example
RLGHNCXA21W 09-02-07 12:01:43 EST EAGLE 41.1.0 0023.1157 CARD 1109 INFO Major congestion event detected Report Date:09-02-07 Time:12:01:43
Alarm Level: No alarm condition. The message is informational only.
Recovery
UIMs
3-208 EAGLE Unsolicited Alarm and Information Messages Reference
Although no action is required, the message can serve as a notification that thisparticular section of the IMT bus is reaching its saturation.
Contact the My Oracle Support (MOS) for more information.
1158 - Minor HIPR2 switching capacity reached
This message is issued when the minor switching rate is observed by the HIPR2 card.This rate is a measure of the switching capacity of the HIPR2 card.
Example
RLGHNCXA21W 09-02-07 12:01:43 EST EAGLE 41.1.0 0023.1158 CARD 1109 INFO Minor HIPR2 switching capacity reached Report Date:09-02-07 Time:12:01:43
Alarm Level: No alarm condition. The message is informational only.
Recovery
Contact the My Oracle Support (MOS).
1159 - Major HIPR2 switching capacity reached
This message is issued when the major switching rate is observed by the HIPR2 card.This rate is a measure of the switching capacity of the HIPR2 card.
Example
RLGHNCXA21W 09-02-07 12:01:43 EST EAGLE 41.1.0 0023.1159 CARD 1109 INFO Major HIPR2 switching capacity reached Report Date:09-02-07 Time:12:01:43
Alarm Level: No alarm condition. The message is informational only.
Recovery
Contact the My Oracle Support (MOS).
1164 - Inh LNP SS request already outstanding
An inh-map-ss command is already entered and queued.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1164 SYSTEM INFO Inh LNP SS request already outstanding
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1166 - ACG Node Overload Level Change
The SCM has detected that the node overload level for the system has changed.
Example
UIMs
UAM and UIM Troubleshooting Procedures 3-209
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1166 SYSTEM INFO ACG Node Overload Level ChangeOLD ACG LEVEL= 0 NEW ACG LEVEL= 10
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1167 - SIP connection established
This message indicates that the SIP connection has been established.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 0014.1167 CARD 1101 INFO SIP connection established Connection Name : tcp1101d Report Date:10-10-12 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1168 - SIP connection terminated
This message indicates that the SIP connection has been terminated.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 0014.1168 CARD 1101 INFO SIP connection terminated Connection Name : tcp1101d Report Date:10-10-12 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1170 - OAMHC Meas transition complete.
The full capabilities of the E5-OAM Integrated Measurements feature are availablenow. The Measurements Platform, if in use before the transition, has been replaced bythe the E5-OAM Integrated Measurements feature.
Example
RLGHNCXA21W 09-11-17 12:01:43 EST EAGLE 42.0.0 yyyy.1170 SYSTEM INFO OAMHC Meas transition complete. Report Date:09-11-17 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action required.
UIMs
3-210 EAGLE Unsolicited Alarm and Information Messages Reference
1171 - Schd UI Rpt disbld-link cnt exceeds 700
To prevent sending too much information to the terminal during the time available,the E5-OAM Measurements Interface feature disables UI reports whenever thenumber of provisioned links is greater than 700 .
Example
RLGHNCXA21W 09-11-17 16:20:19 EST EAGLE 42.0.0 0014.1171 SYSTEM INFO Schd UI Rpt disbld-link cnt exceeds 700
Report Date:09-11-17 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action required.
1172 - REPT-OVSZMSG: MTP MSU too large to rte
An oversized MTP MSU was received and discarded.
Example
0056.1172 CARD 1113 INFO REPT-OVSZMSG: SCCP MSU too large to rte LEN=50 SIO=04 OPC= 016-032-048 DPC= 032-032-048 SCCP MT=012 CDPA: AI=04 PC= 016-032-048 SSN=004 TT=004 ADDR=43210FEDCBA9876543210 CGPA: AI=04 PC= 016-032-048 SSN=004 TT=004 ADDR=0123456789ABCDEF01234 LSN=ls211 Report Date:12-12-15 Time:11:03:31;
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1174 - Inh INP SS request alrdy outstanding
An inh-map-ss command is already entered and queued.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1174 SYSTEM INFO Inh INP SS request alrdy outstanding
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
UIMs
UAM and UIM Troubleshooting Procedures 3-211
1176 - Unexpected DB version - Using UDT
This message indicates that an unexpected DB version was received from the MPSduring the database download. As a result, the UDP-based Data Transfer protocol willbe used to transfer the database from the MPS to the Eagle 5.
Example
0020.1176 CARD 1113 INFO Unexpected DB version – using UDT Report Date:02-07-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1185 - GTI input clock anomalies detected
This message indicates additional high speed clock diagnostic data is availablealthough the high speed clocks are valid.
Example
RLGHNCXA21W 03-01-06 13:46:23 EST EAGLE 35.0.0 0379.1185 CARD 1113 INFO GTI input clock anomalies detected Reporting TDM Location : 1114 GTI Clock Status Register : H'0021 Primary LIU Violation Count : 56 Secondary LIU Violation Count : 129 GTI Status Register : H'0022 Report Date:03-01-05 Time:13:46:25
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1186 - Meas data load failure: old version
This message can be generated if the primary MCP is running an older version of theGPL than the secondary MCP. This could possibly occur in an upgrade failure orupgrade back out procedure.
Example
RLGHNCXA21W 02-07-21 16:20:19 EST EAGLE 31.3.0 0002.1186 CARD 1103 INFO Meas data load failure: old version Report Date:02-07-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
Boot the primary and/or secondary MCPs with the approved GPL version of thesystem release.
UIMs
3-212 EAGLE Unsolicited Alarm and Information Messages Reference
1187 - Table Checksum Mismatch
This message indicates additional diagnostic information in the event of a GPL or aspecific table corruption alarm. Whenever a GPL corruption alarm (UAM 0040) israised during the GPL Audit or a subset data corruption alarm (UIM 1188) is raisedduring static data Audit, this UIM 1187 is also output to provide the Table ID,Reference Checksum, and Calculated Checksum of the GPL or the specific tableinquestion.
Example
RLGHNCXA21W 07-01-06 13:46:23 EST EAGLE 41.0.0 0014.1187 CARD 1113 INFO Table Checksum Mismatch TBL ID = 136 CALC CHKSUM=H’B7C0 REF CHKSUM=H’4A5F
Alarm Level: No alarm condition. The message is informational only.
Recovery
Refer to the recovery procedure for the appropriate UAM that accompanied thisalarm.
1188 - DB Subset Checksum Mismatch
This message indicates additional diagnostic information in the event of DBcorruption alarm (UAM 35, 38, or 427). Whenever a DB corruption is detected duringthe DB audit, this UIM 1188 is also output to provide the Table ID, ReferenceChecksum, and Calculated Checksum of the DB Subset in question.
Example
RLGHNCXA21W 03-01-06 13:46:23 EST EAGLE 35.0.0 0008.1188 CARD 1113 INFO DB Subset Checksum Mismatch SUBSET = 3 CALC CHKSUM = H'abcd REF CHKSUM = H' Report Date:03-01-06 Time:13:46:25
Alarm Level: No alarm condition. The message is informational only.
Recovery
Refer to the recovery procedure for the appropriate UAM that accompanied thisalarm.
1194 - IP Connection Refused, RHOST mismatch
This message indicates that an association in MATCH validation mode cannot beestablished due to mismatch in configured RHOST or ARHOST with the INITmessage contents.
Example
station1234 09-09-21 16:28:08 EST Rel 41.0.0-62.6.0 0003.1194 CARD 1213,A INFO IP Connection Refused, RHOST mismatch RIPADDR = 123.123.123.123 RPORT = 1314 LIPADDR = 123.123.123.124 LPORT = 1315 SNAME = LONGSOCKETNAME1
UIMs
UAM and UIM Troubleshooting Procedures 3-213
Alarm Level: No alarm condition. The message is informational only.
Recovery
Check ARHOST provisioning.
Reports on connection status can be obtained for each DCM card with the followingcommands:
pass:loc=xxxx:cmd=”connmgr -l” displays the connection manager eventlog.pass:loc=xxxx:cmd=”connmgr -c” displays socket client data.pass:loc=xxxx:cmd=”connmgr -s” displays socket server data.
1197 - IP Connection refused
Reports that an attempt to connect to an IP client was rejected by the client.
Example
RLGHNCXA03W 99-04-10 16:28:08 EST EAGLE 35.0.00003.1197 DCM 1213,A IP Connection refusedRIPADDR = 123.123.123.123RPORT = 1314LIPADDR = 123.123.123.124 LPORT = 1315SNAME=UnknownReport Date: 02-04-10 Time: 16:27:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
Reports on connection status can be obtained for each DCM card with the followingcommands:
pass:loc=xxxx:cmd=”connmgr -l” displays the connection manager eventlog.pass:loc=xxxx:cmd=”connmgr -c” displays socket client data.pass:loc=xxxx:cmd=”connmgr -s” displays socket server data.
1198 - IP Connection, Cannot resolve RHOST(S)
Reports that an attempt to connect to an IP client failed because the hostname, RHOSTand ARHOST (if configured), could not be found on the IP network.
Example
RLGHNCXA03W 02-07-21 16:20:19 EST EAGLE 41.0.0 0003.1198 CARD 1213,A INFO IP Connection, Cannot resolve RHOST(S) RIPADDR = Unknown RPORT = 1314 LIPADDR = 123.123.123.124 LPORT = 1315 SNAME = LONGSOCKETNAME1 Report Date:02-07-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
UIMs
3-214 EAGLE Unsolicited Alarm and Information Messages Reference
Recovery
No action necessary.
Reports on connection status can be obtained for each DCM card with the followingcommands:
pass:loc=xxxx:cmd=”connmgr -l” displays the connection manager eventlog.pass:loc=xxxx:cmd=”connmgr -c” displays socket client data.pass:loc=xxxx:cmd=”connmgr -s” displays socket server data.
1199 - LNP DTH Measurements Discarded for DPC
Reports that LNP DTH measurements are being discarded because the capacity of theSSP DTH table has been exceeded.
Example
RLGHNCXA03W 00-04-10 16:28:08 EST EAGLE 35.0.01234.1199 SYSTEM INFO LNP DTH Measurements Discarded for DPCDPC=001-001-001Non-Zero Measurements Discarded: Yes
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. If the Non-Zero Measurements Discarded flag is set No, the discardedmeasurements are all zero, no action is necessary.
Note: If the Non-Zero Measurements Discarded flag is set Yes, Daily LNPMeasurements will be lost for the specified DPC from the time of the LIM1199 occurrence until the end of the day.
2. To retrieve the prior hour LNP SSP measurement pegs. Refer to the MeasurementsManual.
To retrieve the prior hour LNP measurements or other specific periods, set theAccessible Collection Period: Last or Specific.
Example: rept-meas:type=mtch:enttye=lnp:period=last
1200 - INW ALT card as first to be preloaded
Reports the alternate card the system selected to be loaded with GPLs and data.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1200 SYSTEM INFO INW ALT card as first to be preloadedCARD=1203 GPL=SS7ANSI
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
UIMs
UAM and UIM Troubleshooting Procedures 3-215
1201 - INW MAIN card as last to be reset
Reports the main card the system selected to be loaded with GPLs and data.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1201 SYSTEM INFO INW MAIN card as last to be resetCARD=1203 GPL=SS7ANSI
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1202 - INW Asserted DDL inhibition
Reports that card cross loading is inhibited.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1202 SYSTEM INFO INW Asserted DDL inhibitionCARD=1203 GPL=SS7ANSI
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1203 - INW Card reset command issued
Reports that a card reset command has been issued.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1203 SYSTEM INFO INW Card reset command issuedCARD=1203 GPL=SS7ANSI
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1204 - INW Waiting for card loading validation
Reports that INW is waiting for validation of card loading.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1204 SYSTEM INFO INW Waiting for card loading validationCARD=1203 GPL=SS7ANSI
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
UIMs
3-216 EAGLE Unsolicited Alarm and Information Messages Reference
1205 - INW Detected card loaded
Reports that INW has detected a successful completion of a card loading.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1205 SYSTEM INFO INW Detected card loadedCARD=1203 GPL=SS7ANSI
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1206 - INW Detected card reset or removed
Reports that INW has detected the reset or removal of a card.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1206 SYSTEM INFO INW Detected card reset or removedCARD=1203 GPL=SS7ANSI
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1207 - INW Allowed card to skip DDL inhibited
Reports that a card is being allowed to crossload.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1207 SYSTEM INFO INW Allowed card to skip DDL inhibitedCARD=1203 GPL=SS7ANSI
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1208 - INW Removed DDL inhibition
Reports that INW has removed the Dynamic Data Loading (DDL) inhibition on a card.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1208 SYSTEM INFO INW Removed DDL inhibitionCARD=1203 GPL=SS7ANSI
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
UIMs
UAM and UIM Troubleshooting Procedures 3-217
1209 - INW Need to reset/remove/inhibit card
Reports that card must be manually reset, removed, or inhibited.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1209 SYSTEM INFO INW Need to reset/remove/inhibit cardCARD=1203 GPL=SS7ANSI
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1210 - INW Card failed to reset
Reports that card has failed to reset.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1210 SYSTEM INFO INW Card failed to resetCARD=1203 GPL=SS7ANSI
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1211 - INW Failed to assert DDL inhibition
Reports that a DDL inhibition has failed.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1211 SYSTEM INFO INW Failed to assert DDL inhibitionCARD=1203 GPL=SS7ANSI
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1212 - INW Failed to remove DDL inhibition
Reports that an attempt to remove DDL inhibition has failed.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1212 SYSTEM INFO INW Failed to remove DDL inhibitionCARD=1203 GPL=SS7ANSI
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
UIMs
3-218 EAGLE Unsolicited Alarm and Information Messages Reference
1213- INW Card failed to DDL crossload
Reports that a card failed to DDL crossload.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014. SYSTEM INFO INW Card failed to DDL crossloadCARD=1203 GPL=SS7ANSI
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1214 - INW Allowed card to DDL crossload
Reports that a card was allowed to crossload.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1214 SYSTEM INFO INW Allowed card to DDL crossloadCARD=1203 GPL=SS7ANSI
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1233 - MTP Invalid ITU TFR RCVD
This message indicates an ITU TFR (Transfer Restricted) procedure was received on alinkset that is not configured to receive these procedures.
Example
RLGHNCXA21W 00-11-18 19:12:00 EST EAGLE 35.0.00147.1233 CARD 1201,A INFO MTP Invalid ITU TFR RCVDOPC=001-001-001 CPC=002-002-002LSN=lsn01a
Legend
CPCConcerned point code
LSNLinkset name
OPCOrigination point code
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. Verify whether the MTP (Message Transfer Part) is supposed to support anITUTFR on the linkset on which it was received.
UIMs
UAM and UIM Troubleshooting Procedures 3-219
The ITUTFR procedure is valid for ITU national linksets only. As currentlyconfigured, the linkset does not accept TFRs.
2. If ITUTFRs are to be accepted on the linkset, you must reconfigure the linkset toaccept them.
Use the itutfr=on parameter in the chg-ls command to enable the transferrestricted procedure. You must specify this parameter on each ITU national linksetyou want to receive ITUTFRs.
1234 - LNP Day Meas. Discarded for NPANXX
This message is indicates that the Daily LNP NPANXX measurement counts areincorrect because of discards due to provisioning.
Example
station5 00-04-18 19:12:00 EST EAGLE 31.00002.1234 CARD 1201 INFO LNP Day Meas. Discarded for NPANXX
Alarm Level: No alarm condition. The message is informational only.
Recovery
Correct counts can be derived via calculation from LNP queries - discards - LRN pegs.
1235 - Unable to connect Primary SFLOG Server
This message indicates the connection to Primary SFLOG server cannot be established.
Example
0002.1235 CARD 1201 INFO Unable to connect Primary SFLOG server IP: 123.678.123.467 FTP Error: 24 File Name: tekelecstp_sflog_150429_031655.pcap
Report Date: 15-04-30 Time: 16:27:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1236 - Unable to connect both SFLOG Servers
This message indicates the connection to the Primary and Secondary SFLOG serverscannot be established.
Example
0002.1236 CARD 1202 INFO Unable to connect both SFLOG servers IP: 123.678.123.467 FTP Error: 11 File Name: tekelecstp_sflog_150429_031655.pcap
Report Date: 15-04-30 Time: 16:27:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
UIMs
3-220 EAGLE Unsolicited Alarm and Information Messages Reference
1237 - Dynamic database audit not current
The dynamic database audit cannot determine whether the dynamic database isinconsistent because there has not been the required quiet period (500 milliseconds bydefault) to perform the audit. There are always inconsistencies among the copies of thedynamic database on the LIM and Service Module cards while the networks isupdating the cards.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1237 SYSTEM INFO Dynamic database audit not current
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. Determine whether there are issues with links, point codes, linksets, or SSN that arecausing network status changes. If so, use your site's normal procedures to addressthe problems.
2. Contact the My Oracle Support (MOS).
1238 - Full LNP database reload initiated
This message indicates that a cold restart is required for a TSM/BLM card. In thiscase, the entire LNP database is reloaded to the card.
Example
station1234 96-08-01 16:28:08 EST EAGLE 35.0.01234.1238 SYSTEM INFO Full LNP database reload initiated:CARD=1101 GPL=SCCP CAUSE=<xxxxxxxx>
where <xxxxxxxx> is one of the following parameters:
Table 3-6 CAUSE Parameters
Parameter Description
XILINX M256 Xilinx version has changed.
POWER ON Power on reset.
DB VER LNP database version has changed.
DB LVL Database level is not supported or differenceexceeds incremental loading capability.
HW ERR Hardware error bit checks on the card fail.
CHECKSUM Checksum comparisons of the LNP databasefail.
NO AUDIT Unable to perform LNP DB audit. LNP auditnot on or excessive number of unknownchecksums.
UIMs
UAM and UIM Troubleshooting Procedures 3-221
Table 3-6 (Cont.) CAUSE Parameters
Parameter Description
USER REQ User initiated init-card or init-sys commandreload type cold.
OTHER Other or unknown.
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. If this UIM indicates that there is a hardware error or the database checksum testfailed, there may be a hardware problem.
When this condition repeats (the board resets and displays the same conditionsagain), do the following:
a. Reseat the card.
b. Replace the card to determine if it is defective.
2. For additional support, contact the My Oracle Support (MOS).
1239 - Ntwrk Card Reload Failed during Upg
This message indicates the OAM has determined that a card has failed to load.
Example
xxxx.1239 SYSTEM INFO Ntwrk Card Reload Failed during Upg CARD=1103 GPL=SS7ANSI Report Date:02-01-08 Time:01:24:34
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. Manually download card(s) running non-approved flash.
1240 - MAP SCCP Validation Fail
This message indicates that the MAP and SCCP parameter validation performed bySCPVAL GTT Action has failed. Look for the validation failure reason printed by theUIM.
Example
5072.1240 CARD 1105 INFO GTT Action MAP-SCCP validation FAILED Cause: SMRPDA-CDPA Digits Mismatch OPC= 7-101-0 DPC= 1-001-0 CDPA: NI=0 RI=0 GTI=04 SSNI=0 PCI=1 TT=010 NP=01 NAI=004 ADDR=9192051234 PC= 1-001-0 SSN=--- CGPA: NI=0 RI=1 GTI=00 SSNI=1 PCI=1 PC= 7-101-0 SSN=008 SMRPDA: NP=1 NON=1 ADDR=9192056000 LSN=ls710100 Op-Code= 46 GTT Action Set=scpval1
UIMs
3-222 EAGLE Unsolicited Alarm and Information Messages Reference
Report Date:15-08-01 Time:15:50:30
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1241 - SCCP Card logging capacity exceeded
This message indicates the SCCP card logging capacity has been exceeded.
Example
XXXX.1241 CARD XXXX INFO SCCP Card logging capacity exceeded
Alarm Level: No alarm condition. The message is informational only.
Recovery
Reduce the card logging below the recommended capacity level.
1251 - Measurements data copy failure
Measurements data is copied to all MCPM cards after collection. Measurements datacopy to a Secondary MCPM failed.
Example
station5 00-04-18 19:12:00 EST EAGLE 31.3.00002.1251 CARD 1201 INFO Measurements data copy failure
Alarm Level: No alarm condition. The message is informational only.
Recovery
There is no immediate action needed, but the message indicates that the error wasencountered.
1252 - Report generation failure
This message is generated by the Primary MCPM. The measurement report identifiedin the output message did not generate.
Example
station5 00-04-18 19:12:00 EST EAGLE 31.3.00002.1252 CARD 1201 INFO Report generation failureIP:111.111.111.111 FTP Error: XXXXFile Name: tues_serv.csv
Alarm Level: No alarm condition. The message is informational only.
Recovery
Enter the rept-ftp-meas command to manually initiate the generation and FTPtransfer of the indicated measurement report.
Refer to the Commands Manual for the correct usage of this command.
UIMs
UAM and UIM Troubleshooting Procedures 3-223
1253 - Report transfer failure FTP Server
This message is generated by the Primary MCPM. The FTP transfer of the indicatedreport failed.
Example
station5 00-04-18 19:12:00 EST EAGLE 31.3.00002.1253 CARD 1201,A INFO Report transfer failure FTP ServerIP:111.111.111.111 FTP Error: XXXXFile Name: tues_serv.csv
Alarm Level: No alarm condition. The message is informational only.
Recovery
Enter the rept-ftp-meas command to manually initiate the generation and FTPtransfer of the indicated measurement report. Refer to the Commands Manual for thecorrect usage of this command.
1254 - Scheduled transfer failure
This message is generated by the Primary MCPM. Some of the reports scheduled to begenerated and transferred were not transferred.
Example
station5 00-04-18 19:12:00 EST EAGLE 31.3.00002.1254 CARD 1201 INFO Scheduled transfer failure
Alarm Level: No alarm condition. The message is informational only.
Recovery
Enter the rept-ftp-meas command to manually initiate the generation and FTPtransfer of the affected measurement report. Refer to the Commands Manual for thecorrect usage of this command.
1257 - DB restore has cleared and Disabled PDS
A DB restore has rendered the data on PDS table obsolete. The PDS table will beupdated when the OAM is rebooted.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00014.1257 SYSTEM INFO DB restore has cleared and Disabled PDS
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1298 - SIP message decode failed
SIP message parsing FAILS. Examples of decoding fail:
1. TEL-URI with a Local Number does not contain a "phone-context" parameter
2. SIP-URI does not contain "user=phone" parameter
UIMs
3-224 EAGLE Unsolicited Alarm and Information Messages Reference
3. SIP INVITE does not have E164 num
Example
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890 0014.1298 CARD 1103,B INFO SIP msg decode failed CSeq No: 96781 Cname: tcp1107d Reason: Incorrect Content-Length Header Report Date:10-10-12 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1305 - MTP rcvd UPU - User SCCP, Cause invalid
This message is generated for a UPU message for a SCCP user when the unavailabilitycause indicates a SCCP translation exists for a node that does not have a SCCP userpart.
Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.00100.1305 CARD 1201,A INFO MTP rcvd UPU - user SCCP, Cause invalidSIO=03 OPC=003-232-000 DPC=001-004-000AFTPC=004-000-001 UPU=03 UNAVAIL CAUSE=001LSN=A1234567
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1306 - GSMOPTS: EIR Global Response is ON
The EIR Global Response Type is on. The EIR Global Response Type is set by the chg-gsmopts command and the eirgrsp parameter.
The Global Response Type is used to override the response that is returned to the MSC(Mobile Switching Center). The default value is OFF. When this parameter to OFF, thenormal list logic is applied to the IMEI. If the Global Response Type is set to a valueother than OFF, there is no list logic processing, and the response corresponding to theeirgrsp value is sent to the MSC.
For more information about eirgrsp, refer to the chg-gsmopts command in theCommands Manual.
Example
RLGHNCXA21W 03-08-18 19:09:14 EST EAGLE 31.3.00140.1306 CARD 1201 INFO GSMOPTS: EIR Global Response is ON
Alarm Level: No alarm condition. The message is informational only.
Recovery
No corrective action is required.
UIMs
UAM and UIM Troubleshooting Procedures 3-225
1307 - GSMOPTS: EIR Global Response is OFF
The EIR Global Response Type is off. The EIR Global Response Type is set by thechg-gsmopts command and the eirgrspparameter.
The Global Response Type is used to override the response that is returned to the MSC(Mobile Switching Center). The default value is OFF. When this parameter to OFF, thenormal list logic is applied to the IMEI. If the Global Response Type is set to a valueother than OFF, there is no list logic processing, and the response corresponding to theeirgrsp value is sent to the MSC.
For more information about eirgrsp, refer to the chg-gsmopts command in theCommands Manual.
Example
RLGHNCXA21W 03-08-18 19:09:14 EST EAGLE 31.3.00140.1307 CARD 1201 INFO GSMOPTS: EIR Global Response is OFF
Alarm Level: No alarm condition. The message is informational only.
Recovery
No corrective action is required.
1308 - Updates inhibited: Target-Cell CRC Fail
This message appears if the new source-cell and the target-cell checksums do notmatch. This message, similar to UIM 1239, but including the table id, shall be issued bythe Eagle User Interface (UI) for each event.
Example
station1234 96-08-01 16:28:08 EST EAGLE 34.0.0 1234.1308 SYSTEM INFO Updates inhibited:Target-Cell CRC Fail CARD=1107 TABLE=50 OFFSET=XXXX TRGT CRC=1423697
Alarm Level: No alarm condition. The message is informational only.
Recovery
This is an automatic process and no action is necessary.
1309 - Updates inhibited: Source-Cell CRC Fail
If the source cell fails validation this message, similar to UIM 1239, but including thetable ID, shall be issued by the Eagle User Interface (UI) for each event.
Example
station1234 96-08-01 16:28:08 EST EAGLE 34.0.0 1234.1309 SYSTEM INFO Updates inhibited:Source-Cell CRC Fail CARD=1107 TABLE=50 OFFSET=XXXX
Alarm Level: No alarm condition. The message is informational only.
Recovery
This is an automatic process and no action is necessary.
UIMs
3-226 EAGLE Unsolicited Alarm and Information Messages Reference
1310 - System Meas. Limit exceeded for LRN
This UIM is issued if the Measurements Platform is not enabled and if the number ofprovisioned LRNs exceeds 100,000. When the limit of 100,000 is exceeded, this UIM isnotification that the LNP LRN measurements report will be truncated, and additionalLRN measurements will not be collected or reported.
Example
RLGHNCXA21W 00-04-18 19:09:14 EST EAGLE 31.3.00140.1310 CARD 1201 INFO System Meas. Limit exceeded for LRN
Alarm Level: No alarm condition. The message is informational only.
Recovery
You have two options if this UIM appears:
• Install the Measurements Platform to increase the reporting limits, or
• If you have any unused LRN entries, you can remove them such that the numberof provisioned LRNs does not exceed the limit of 100,000.
1311 - System Meas. Limit exceeded for NPANXX
This UIM is issued if the Measurements Platform is not enabled and if the number ofprovisioned NPANXXs exceeds 150,000. When the limit of 150,000 is exceeded, thisUIM is notification that the LNP NPANXX measurements report will be truncated,and additional NPANXX measurements will not be collected or reported.
Example
RLGHNCXA21W 00-04-18 19:09:14 EST EAGLE 31.3.00140.1311 CARD 1201 INFO System Meas. limit exceeded for NPANXX
Alarm Level: No alarm condition. The message is informational only.
Recovery
You have two options if this UIM appears:
• Install the Measurements Platform to increase the reporting limits, or
• If you have any unused NPANXX entries, you can remove them such that thenumber of provisioned NPANXXs does not exceed the limit of 150,000.
1312 - LSS: Interrogation Type missing
This UIM occurs when the Interrogation type is missing from the SRI.
Example
RLGHNCXA21W 00-04-18 19:09:14 EST EAGLE 33.2.00140.1312 Application Subsystem 1201 INFO LSS: Interrogation Type missing
Alarm Level: No alarm condition. The message is informational only.
Recovery
Modify the SRI to include the Interrogation Type parameter.
UIMs
UAM and UIM Troubleshooting Procedures 3-227
1313 - LSS: Invalid Interrogation Type
This UIM occurs when the SRI Interrogation Type is not valid for NT NumberTranslation.
Example
RLGHNCXA21W 00-04-18 19:09:14 EST EAGLE 33.2.00140.1313 Application Subsystem 1201 INFO LSS: Invalid Interrogation Type
Alarm Level: No alarm condition. The message is informational only.
Recovery
Set the Interrogation Type to 30 for NP Number Translation queries.
1314 - LSS: MSISDN missing
This UIM occurs when the SRI does not contain MSISDN parameter.
Example
RLGHNCXA21W 00-04-18 19:09:14 EST EAGLE 31.3.00140.1314 Application Subsystem 1201 INFO LSS: MSISDN missing
Alarm Level: No alarm condition. The message is informational only.
Recovery
Modify the SRI to include the MSISDN parameter.
1315 - ICNP: Response PC prohibited
This UIM occurs when the OPC of the IAM for processing is not accessible.
Example
RLGHNCXA21W 00-04-18 19:09:14 EST EAGLE 31.3.00140.1315 CARD 1201 INFO ICNP: Response PC prohibited
Alarm Level: No alarm condition. The message is informational only.
Recovery
If this UIM appears, take these actions:
1. Check the status of the point code via rept-stat-dstn.
2. Perform provisioning and maintenance activities to make the point code allowed.
1316 - ICNP: Invalid Message received
This UIM occurs when an unexpected ISUP message is received.
Example
RLGHNCXA21W 00-04-18 19:09:14 EST EAGLE 33.2.00140.1316 CARD 1201 INFO ICNP: Invalid Message received
Alarm Level: No alarm condition. The message is informational only.
Recovery
UIMs
3-228 EAGLE Unsolicited Alarm and Information Messages Reference
Modify the originator of the message to send valid ISUP messages for this feature(IAM, SAM, REL, RLC) only.
1317 - ICNP: Response PC unknown
This UIM occurs when the OPC of the IAM for processing is not known..
Example
RLGHNCXA21W 00-04-18 19:09:14 EST EAGLE 33.2.00140.1317 CARD 1201 INFO ICNP: Response PC unknown
Alarm Level: No alarm condition. The message is informational only.
Recovery
If this UIM appears, take these actions:
• Check the point code using the rtrv-dstn command.
• Perform provisioning activities to make the point code allowed.
1318 - ICNP: OPC/DPC correlation problem
This UIM occurs when the DPC of the IAM is not the True or Secondary Point Codeassigned to the OPC in the routing table.
Example
RLGHNCXA21W 00-04-18 19:09:14 EST EAGLE 33.2.00140.1318 CARD 1201 INFO ICNP: OPC/DPC correlation problem
Alarm Level: No alarm condition. The message is informational only.
Recovery
Make sure that the OPC is using the True or Secondary Point code assigned to it in therouting table as the DPC of the IAM.
1319 - ICNP: IDCA not reachable
This UIM when the required IDCA application is not currently reachable.
Example
RLGHNCXA21W 00-04-18 19:09:14 EST EAGLE 31.3.00140.1319 CARD 1201 INFO ICNP: IDCA is not reachable
Alarm Level: No alarm condition. The message is informational only.
Recovery
If this UIM appears, take these actions:
• Bring the IDCA application online.
• Verify the connection between the EAGLE and IDCA.
UIMs
UAM and UIM Troubleshooting Procedures 3-229
1320 - FPT value unprovisioned for frame
This UIM is periodically raised at hourly intervals, starting at the system initializationtime, for all the provisioned frames if the Frame Power Threshold value is notprovisioned for that frame.
Example
RLGHNCXA21W 00-04-18 19:05:43 EST EAGLE 35.00021.1320 CARD 1113 INFO FTP value unprovisioned for frame CF00
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. Verify that the Frame Power Threshold value is not configured for the provisionedframe for which the UIM is generated by using the following command:
rtrv-frm-pwr
2. Configure the appropriate Frame Power Threshold value for the frame using thefollowing command:
ent-frm-pwr
Otherwise, contact the My Oracle Support (MOS) about the generated UIM.
1321 - Eagle RTDB Birthdate Mismatch
This message appears if the EAGLE 5 ISS connects to an ELAP and the birthdates donot match between the RTDB on the ELAP and the RTDB on the EAGLE 5 ISS.
Example
RLGHNCXA21W 00-04-18 19:09:14 EST EAGLE 35.0.00008.1321 SYSTEM INFO Eagle RTDB Birthdate Mismatch
Alarm Level: No alarm condition. The message is informational only.
Recovery
Contact the My Oracle Support (MOS).
1322 - Eagle RTDB Levels Invalid
This message appears if the EAGLE 5 ISS connects to an ELAP and the ELAP's RTDBdb-level is less-than the EAGLE 5 ISS's RTDB db-level.
Example
RLGHNCXA21W 00-04-18 19:09:14 EST EAGLE 35.0.00008.1322 SYSTEM INFO Eagle RTDB Levels Invalid
Alarm Level: No alarm condition. The message is informational only.
Recovery
Contact the My Oracle Support (MOS).
UIMs
3-230 EAGLE Unsolicited Alarm and Information Messages Reference
1323 - Eagle/Elap TN Quantity Mismatch
This message appears if the EAGLE 5 ISS connects to an ELAP that has a greaternumber of TNs provisioned than the EAGLE 5 ISS's quantity keys allow.
Example
RLGHNCXA21W 00-04-18 19:09:14 EST EAGLE 35.0.00008.1323 SYSTEM INFO Eagle/Elap TN Quantity Mismatch
Alarm Level: No alarm condition. The message is informational only.
Recovery
Contact the My Oracle Support (MOS).
1324 - Eagle/Elap NPANXX Quantity Mismatch
This message appears if the EAGLE 5 ISS connects to an ELAP that has a greaternumber of NPANXXs provisioned than the EAGLE 5 ISS's quantity keys allow.
Example
RLGHNCXA21W 00-04-18 19:09:14 EST EAGLE 35.0.00008.1324 SYSTEM INFO Eagle/Elap NPANXX Quantity Mismatch
Alarm Level: No alarm condition. The message is informational only.
Recovery
Contact the My Oracle Support (MOS).
1325 - Eagle/Elap LRN Quantity Mismatch
This message appears if the EAGLE 5 ISS connects to an ELAP that has a greaternumber of LRN s provisioned than the EAGLE 5 ISS's quantity keys allow.
Example
RLGHNCXA21W 00-04-18 19:09:14 EST EAGLE 35.0.00008.1325 SYSTEM INFO Eagle/Elap LRN Quantity Mismatch
Alarm Level: No alarm condition. The message is informational only.
Recovery
Contact the My Oracle Support (MOS).
1326 - Eagle RTDB Depth Alert
RTDB data is stored as inverse tree structures the trees have a maximum depthallowed. This alarm indicates that the maximum depth has been reached for a tree. Ifthe alarm was initiated during a data update, the update will continually fail untilthere is manual intervention.
Example
RLGHNCXA21W 00-04-18 19:09:14 EST EAGLE 35.0.00008.1326 SYSTEM INFO Eagle RTDB Depth Alert
Alarm Level: No alarm condition. The message is informational only.
UIMs
UAM and UIM Troubleshooting Procedures 3-231
Recovery
Contact the My Oracle Support (MOS).
1331 - IP Route Table Entry Conflict
A conflict exists between user configured static IP routes and dynamically addedroutes. (The Integrate Message Feeder application monitoring dynamically createshost specific IP routes to an IMFVIP address.) There are two scenarios in which such aconflict can result:
1. If an Integrated Message Feeder application receives a service accept message andattempts to add a host specific IP route for the IP address received in the serviceaccept message and there is an user configured static IP route (entered by ent-ip-rteEAGLE 5 ISS command) whose destination is the same IP address, thenthe route is not added and the UIM is sent indicating the route and result.
2. If a user enters a host specific IP route using the ent-ip-rte command andthere currently exists a dynamically added route with the same destination IPaddress, then the dynamic route is deleted, the static route is added, and this UIMindicating the result is generated.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00003.1331 CARD 1213 INFO IP Route Table Entry ConflictDynamic IP Route Add FailDestination = 172.130.155.110Gateway = 172.120.154.111Mask = 255.255.255.255Report “Date:02-02-21 Time:02:07:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
Resolve the IP Address conflict.
One must either change the Integrated Message Feeder application VIP address ordelete the static IP address using the following command:
dlt-ip-rte
1333 - UA RCVD MSG DISCARDED
When processing a received PDU at the UA L2 layer, various errors can be detectedwhich cause the MSU to be pegged and discarded. The SG responds to a number ofthese MSU’s with error messages and transmits them to the customer. Some scenariosexist where a received PDU causes an error to be pegged, the message to be discarded,and the SG to not respond with an error message. A new UIM is issued when a PDUexcluding UA ERROR messages is received at the UA L2 layer and results in the SGdiscarding the message plus pegging an error count. The generation of this UIM ispaced (every 30 seconds), and in situations where multiple messages are discardedwithin a 30 second window of time, a UIM is only generated for the first messagediscarded.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 38.0.0 0003.1333 CARD 1305,A INFO UA RCVD MSG DISCARDED IP CONNECTION NAME=LONGCONNECTNAME ADPTR=M3UA
UIMs
3-232 EAGLE Unsolicited Alarm and Information Messages Reference
REASON=Large MSU for IP Sig Not Supported SIO=0D OPC=1-1-1 DPC=2-2-2 Report Date:yy-mm-dd Time:hh:mm:ss
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. The following table summarizes why the UIM was issued.
The “reason” text in the UIM identifies why the UIM was displayed. Look at thereason and take action based on that field. Most of the time, to correct the issue, thecustomer needs to stop issuing the message. The UIM’s diagnostic field usuallyindicates which message was received.
Table 3-7 SG Received Messages Discarded
REASON MSGDISCARDED AND PEGGED UIM ’REASON’ TEXT UIM ‘DIAGNOSTIC’ TEXT
PDU received with invalidversion
Invalid Version (ErrorCode=0x01)
<msg rcvd> Rcvd;Version=<version valuercvd>
Ex. ASP-Inactive Rcvd;Version=0x02
1. PDU has unsupportedclass
3. PDU received was SUACLDT/CLDR on an M3UAAssociation
Unsupported Message Class(Error Code=0x03)
Class=<Message ClassValue>; Type=<MessageType Value> Ex: Class=0x09;Type=0x01
PDU has unsupported type Unsupported Message Type(Error Code=0x04)
Type=<Msg Type Value >;Class=<Message ClassValue >
Ex: Type=0x15; Class=0x02
ASP-ACTIVE contains anunsupported traffic modeType.
Unsupported Traffic Mode(Error Code=0x05)
<MSG> Rcvd;Mode=<traffic modereceived >
Ex : ASP-Active Rcvd;Mode=0x03
1. PDU received wasDAVA/DUNA/DRST/DUPU in the ASP-Inactive/ASP-Active States(endnodes shouldn’t generatethese)
2. ASP-UP received while inASP-ACTIVE state
3. ASP-ACTIVE receivedwhile in ASP-DOWN state
Unexpected Message (ErrorCode=0x06)
1. DUNA Msg Rcvd
2. DAVA Msg Rcvd
3. DRST Msg Rcvd
4. DUPU Msg Rcvd
5. ASP-UP Rcvd while inASP-Act State
6. ASP-Act Rcvd while inASP-Down State
UIMs
UAM and UIM Troubleshooting Procedures 3-233
Table 3-7 (Cont.) SG Received Messages Discarded
REASON MSGDISCARDED AND PEGGED UIM ’REASON’ TEXT UIM ‘DIAGNOSTIC’ TEXT
1. PDU could not bedecoded or invalid length.
2. ASP-UP-ACK/ASP-DOWN-ACK/
ASP-ACTIVE-ACK/ASP-INACTIVE-ACK receivedin the ASP-Inactive/ASP-Active States while in servermode (not client)
3. ASP-INACTIVE-ACKreceived while in clientmode and in ASP-ACTIVEstate
4. DATA contains multiplerouting contexts
Protocol Error (ErrorCode=0x07)
1. <Message> Decode Failed
2. <Message> Encode Failed
3. <Message> LengthInvalid
4. ASP-UP-Ack Rcvd
5. ASP-Down-Ack Rcvd
6. ASP-Active-Ack Rcvd
7. ASP-Inactive-Ack Rcvd
8. M3UA to MTP3Conversion Failed
ASP-UP received on aconnection this isDeactivated or Blocked.
Refused ManagmentBlocking (Error Code=0x0d)
ASP-Active Rcvd when SLKOOS-MT-DSBLD
Sent if a UA Message isreceived with an invalidparameter value.
Invalid Parameter Value(Error Code=0x11)
<msg rcvd> Rcvd;Value=<parameter valuercvd >
Ex. ASP-Inactive Rcvd;Value=0x00000009
PDU has fixed lengthparameters of incorrect size
Parameter Field Error (ErrorCode=0x12)
<msg rcvd> Rcvd;Length=<invalid parameterlength >
Ex. ASP-Inactive Rcvd;Length=0x0200
Sent if a UA messagereceived contains an invalidparameter.
Unexpected Parameter(Error Code=0x13)
<msg rcvd> Rcvd; ParmTag=<parameter tag rcvd >
Ex. DATA Rcvd; ParmTag=0x0500
Invalid NetworkAppearance value receivedin a M3UA message
Invalid NetworkAppearance (ErrorCode=0x15)
<Msg Type> Rcvd;NA=<NA value rcvd >
Ex: DAUD Rcvd;NA=0x00000011
1. PDU is missing one ormore mandatory parameters
2. DATA contains norouting context and theassociation the PDU wasreceived on is configuredwith more than 1 routingcontext
Missing Parameter (ErrorCode=0x16)
1. <Msg Type> Rcvd;Missing Tag=<tag value >
2. Hdr Len Invalid
UIMs
3-234 EAGLE Unsolicited Alarm and Information Messages Reference
Table 3-7 (Cont.) SG Received Messages Discarded
REASON MSGDISCARDED AND PEGGED UIM ’REASON’ TEXT UIM ‘DIAGNOSTIC’ TEXT
1. ASP-ACTIVE receivedwith routing context but norouting key(s) areprovisioned for linkset
2. PDU contains one ormore routing contexts thatcould not be matched to oneassociated with theconnection the PDU wasreceived on
Invalid Routing Context(Error Code=0x19)
For this error code, useexisting UIM “MismatchedUA Routing Context” onlyif the message is stillprocessed. If the message isdiscarded, issue UIMformat 62.
<msg rcvd> Rcvd;RC=<routing contextvalue>
Ex: DAUD Rcvd;RC=0x00000008
DATA received while in theASP-Inactive State (servermode)
Invalid ASP State DATA Rcvd while in ASP-Inact State
A message was discardedand there is no error code.
No ERR Received Reason Unknown
2. Otherwise change the M2PA version at the M2PA peer to match the versionconfigured for the signaling link/association at the Eagle.
3. If the fault is not cleared contact the My Oracle Support (MOS).
1334 - UA TX MSG DISCARDED
The generation of this UIM is paced (every 30 seconds), and in situations wheremultiple messages are discarded within a 30-second window of time, a UIM is onlygenerated for the first transmitted message that is discarded.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 37.0.0 0003.1334 CARD 1305,A INFO UA TX MSG DISCARDED IP CONNECTION NAME=LONGCONNECTNAME ADPTR=M3UA REASON=M3UA Conversion Error SIO=0D OPC=1-1-1 DPC=2-2-2 Report Date:yy-mm-dd Time:hh:mm:ss
Alarm Level: No alarm condition. The message is informational only.
Recovery
Correct the problem based on the “reason” text displayed.
The reasons listed in this UIM cause a discard in the transmit path.
Table 3-8 SG Messages Discarded in the Transmit Path
UIM ’REASON’ TEXT UIM SPECIFIC TEXT
M3UA Conversion Error MTP3 to M3UA Conversion Failed
UIMs
UAM and UIM Troubleshooting Procedures 3-235
1335 - Table Information
An update to the SCCP contained an invalid table identifier.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 35.0.00003.1335 CARD 1105 INFO Table InformationTable 4294967296 Invalid Table IDReport Date:02-07-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1336 - UA ERROR MSG RECEIVED
This UIM is issued for message discards in the transmit path. The generation of thisUIM is paced (every 30 seconds), and in situations where multiple messages arediscarded within a 30-second window of time, a UIM is only generated for the firsttransmitted message that was discarded.
This UIM is being displayed because the customer is sending an error message to theSG. The following is a list of all the possible error codes that can appear in the UIM forreceived UA ERROR messages. Each one has the error code appended in parenthesis.
• Invalid Version (0x01)
• Unsupported Message Class (0x03)
• Unsupported Message Type (0x04)
• Unsupported Traffic Mode (0x05)
• Unexpected Message (0x06)
• Protocol Error (0x07)
• Invalid Stream Identifier (0x09)
• Refused Management Blocking (0x0d)
• ASP Identifier Required (0x0e)
• Invalid ASP Identifier (0x0f)
• Invalid Parameter Value (0x11)
• Parameter Field Error (0x12)
• Unexpected Parameter (0x13)
• Destination Status Unknown (0x14)
• Invalid Network Appearance (0x15)
• Missing Parameter (0x16)
• Invalid Routing Context (0x19)
UIMs
3-236 EAGLE Unsolicited Alarm and Information Messages Reference
• No Configured AS for ASP (0x1a)
• Subsystem Status Unknown (0x1b)
• Invalid Loadsharing Label (0x1c)
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 38.0.00003.1336 CARD 1305,A INFO UA ERROR MSG RECEIVED IP CONNECTION NAME=association1 ADPTR=M3UA ERROR CODE=Missing Parameter (0x16) Report Date:02-07-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
Contact far end node and investigate reason for error.
1340 - REPT COND: TRBL resynch required
Under conditions of prolonged, high alarm activity the alarm processing capacity ofthe EAGLE 5 ISS can be reached. In an effort to keep the internal state machinecurrent, alarms normally generated to the UI are discarded.
Under this scenario, when alarm processing recovers sufficiently, this message isgenerated to indicate to the attached network or element management systems thatthey should resynchronize with the EAGLE 5 ISS.
The generation of this message is expected to be limited to large configurations duringsevere outages, and the expected occurrence rate of this message is low; however, ithas been added as a precaution. Although alarms may have been discarded, theinternal alarm state of the EAGLE 5 ISS has been maintained and is stable.
Example
tekelecstp 99-03-09 12:01:43 EST EAGLE 35.0.05061.1340 SYSTEM INFO REPT COND: TRBL resynch required
Alarm Level: No alarm condition. The message is informational only.
Recovery
The attached network or element management systems (such as Harris NetBoss)should use this message as an indication that they should perform the followingcommand to synchronize alarm status with the EAGLE 5 ISS:
rept-stat-trbl
Note:
Network or element management systems attached through terminalsconfigured as EMSALM type terminals must not filter this message. See thechg-trm command in the Commands Manual for further details.
1.
2. Use the following command to check whether GTT selectors in the arrived MSUare provisioned in SCCPOPTS table:
UIMs
UAM and UIM Troubleshooting Procedures 3-237
rtrv=sccpopts
3. If the SCCPOPTS table does not have an entry with the GTT selectors in thearrived MSU, use the following command to add a record with the GTT selectorsin the arrived MSU to the SCCPOPTS table:
ent-sccpopts
1345 - CRD Auto-Clear Sent to All MTP Cards
EAGLE 5 ISS generates this UIM when Circular Route Auto-Recovery procedureclears the Circular Route Detection (CRD) status of a destination that was markedprohibited.
Example
RLGHNCXA21W 03-04-18 19:02:05 EST EAGLE 36.0.01234.1345 CARD 1203 INFO CRD Auto-Clear Sent to All MTP CardsDPC=001-001-001Report Date:06-06-19 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1347 - IS-41 Digits - Bad Encoding Scheme
EAGLE 5 ISS has rejected the ANSI IS 41 INP Query message, because the encodingscheme of the DIGITS parameter of the ANSI IS-41 TCAP portion is invalid.
Example
tklc1091301 07-01-19 03:31:57 EST EAGLE5 36.0.0-57.9.06925.1347 CARD 2113 INFO IS-41 Digits - Bad Encoding SchemeSIO=83 OPC= 0-000-0-aa DPC= 5-090-5-aaCDPA: AI=d3 SSN=250 TT=025ADDR=197055512340CGPA: AI=c3 PC= 1-137-4-aa SSN=250DATA=23 e2 21 c7 04 00 00 00 00 e8 19 e917 cf 01 00 d1 02 09 3e f2 0e 84 0c01 01 12 0f 76 18 79 70LSN=ls1102n0Report Date:07-01-19 Time:03:31:57
Alarm Level: No Alarm condition. Message is for information only.
Recovery
Ensure ANSI IS 41 INP Query message contains only digits with BCD encodingscheme.
1348 - IS-41 Number of dgts exceeds the maximum
EAGLE 5 ISS has rejected the ANSI IS 41 INP Query message; because the number ofdigits in the DIGITS parameter exceeds 21 digits.
Example
tklc1091301 07-01-19 03:34:40 EST EAGLE5 36.0.0-57.9.06936.1348 CARD 2317 INFO IS-41 Num of dgts exceeds the maximum
UIMs
3-238 EAGLE Unsolicited Alarm and Information Messages Reference
SIO=83 OPC= 0-000-0-aa DPC= 5-090-5-aaCDPA: AI=d3 SSN=250 TT=025ADDR=197055512340CGPA: AI=c3 PC= 1-137-4-aa SSN=250DATA=27 e2 25 c7 04 00 00 00 00 e8 1d e91b cf 01 00 d1 02 09 3e f2 12 84 1001 01 11 18 76 18 79 70LSN=ls1102n0Report Date:07-01-19 Time:03:34:40
Alarm Level: No Alarm condition. Message is for information only.
Recovery
Ensure ANSI IS 41 INP Query message’s DIGITS parameter contains less than 21digits.
1349 - MSU invalid size – discarded
An MSU less than 5 bytes or greater than 279 bytes was detected by the MTP layer 3software in an ATM card. A four byte MSU may cause the ATM connection to bounce(four byte PDUs are used for SSCF control). MSU length limit is 279 bytes.
Example
2864.1349 CARD 6112,A INFO MSU invalid size - discarded LEN=114 SIO=93 OPC= 227-040-000 DPC= 209-122-150 DATA=09 81 03 0c 15 09 89 06 0a 21 80 95 97 10 89 09 89 95 0a 21 80 95 89 30 03 44 62 42 LSN=n209068063 Report Date:13-11-09 Time:09:48:33
Note: The length of the MSU (for example, LEN=114) includes the length ofthe SIF plus some other parameters. The length of these other parametersvaries depending on the protocol managed by the LIM card issuing the UIM.
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1350 - Discrd Rcvd Lrg MSU CTRL-FEAT Off
IPL receives on a M2PA connection a large MSU greater than 272 bytes and the featureis not enabled.
Example
0047.1350 CARD 1113 INFO Discrd Rcvd Large MSU CTRL-FEAT Off LEN=50 SIO=04 OPC= 016-032-048 DPC= 032-032-048 DATA=01 02 03 04 05 06 07 08 09 0a 0b 0c 0d 0e 0f 10 11 12 13 14 15 16 17 18 19 1a 1b 1c LSN=ls211 Report Date:12-12-15 Time:11:01:50;
UIMs
UAM and UIM Troubleshooting Procedures 3-239
Note: The length of the MSU (for example, LEN=50) includes the length ofthe SIF plus some other parameters. The length of these other parametersvaries depending on the protocol managed by the LIM card issuing the UIM.
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. Enter the following command to retrieve information about controlled features:
rtrv-ctrl-feat
The output of the rtrv-ctrl-feat command displays information about theenabled features.
2. The alarm will be cleared when the feature is enabled using the enable-ctrl-feat command.
1351 - Discrd Trans Lrg MSU Unsupported SLK
An MSU less than 5 bytes or greater than 279 bytes was detected by the MTP layer 3software in an ATM card. A four-byte MSU may cause the ATM connection to bounce(four byte PDUs are used for SSCF control). The MSU length limit is 279 bytes. IN thiscase, an SSEDCM-IPLIM SAAL/TALI signaling link receives from IMT a large MSUgreater than 272 bytes. The discard occurs on the outbound card.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 37.0.00003.1351 CARD 1105,B INFO Discrd Trans Lrg MSU Unsupported SLK LEN=475 SIO=0D OPC=001-001-001 DPC=002-002-002 LSN=ABCD123 Report Date:yy-mm-dd Time:hh:mm:ss
Note: The length of the MSU (for example, LEN=50) includes the length ofthe SIF plus some other parameters. The length of these other parametersvaries depending on the protocol managed by the LIM card issuing the UIM.
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1352 - Discrd Rcvd Lrg MSU Unsptd Outbnd SLK
An IP7 GPL receives a large MSU greater than 272 bytes, the BICC controlled feature ison, there are available routes for the destination point code, but selected outboundcard does not support large MSUs.
Example
0049.1352 CARD 1113 INFO Discrd Rcvd Lrg MSU Unsprtd Outbnd SLK LEN=50 SIO=04 OPC= 016-032-048 DPC= 032-032-048 DATA=01 02 03 04 05 06 07 08 09 0a 0b 0c 0d 0e 0f 10 11 12 13 14 15 16 17 18
UIMs
3-240 EAGLE Unsolicited Alarm and Information Messages Reference
19 1a 1b 1c LSN=ls211 Report Date:12-12-15 Time:11:02:11;
Note: The length of the MSU (for example, LEN=50) includes the length ofthe SIF plus some other parameters. The length of these other parametersvaries depending on the protocol managed by the LIM card issuing the UIM.
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1353 - DTA Bypassed for Rcvd Lrg MSU
An IP7 GPL receives a large MSU that triggers DTA processing instead of convertingthe MSU (the MSU is routed normally, DTA is bypassed).
Example
0050.1353 CARD 1113 INFO DTA Bypassed for Rcvd Large MSU LEN=50 SIO=04 OPC= 016-032-048 DPC= 032-032-048 DATA=01 02 03 04 05 06 07 08 09 0a 0b 0c 0d 0e 0f 10 11 12 13 14 15 16 17 18 19 1a 1b 1c LSN=ls211 Report Date:12-12-15 Time:11:02:21;
Note: The length of the MSU (for example, LEN=50) includes the length ofthe SIF plus some other parameters. The length of these other parametersvaries depending on the protocol managed by the LIM card issuing the UIM.
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1354 - STPLAN Copy Bypassed for Lrg MSU
An IP7 GPL receives a large MSU that triggers STPLAN copy instead of copying theMSU (STPLAN is bypassed).
Example
0051.1354 CARD 1113 INFO STPLAN Copy Bypassed for Large MSU LEN=50 SIO=04 OPC= 016-032-048 DPC= 032-032-048 DATA=01 02 03 04 05 06 07 08 09 0a 0b 0c 0d 0e 0f 10 11 12 13 14 15 16 17 18 19 1a 1b 1c LSN=ls211 Report Date:12-12-15 Time:11:02:31;
UIMs
UAM and UIM Troubleshooting Procedures 3-241
Note: The length of the MSU (for example, LEN=50) includes the length ofthe SIF plus some other parameters. The length of these other parametersvaries depending on the protocol managed by the LIM card issuing the UIM.
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1356 - EXT BERT terminated with OAM switchover
This message is issued when the Extended BERT is aborted due to OAM switchover.
Example
RLGHNCXA21W 09-09-07 16:20:19 EST EAGLE 42.0.0 0023.1356 CARD 1115 INFO EXT BERT terminated with OAM switchover Report Date:09-09-07 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1357 - Negotiation at 100Mbps/Full Duplex failed
The negotiation for data rate and traffic flow did not result in 100 Mbps and fullduplex mode respectively, for all data links.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 37.0.00010.1357 CARD 1103 INFO Negotiation at 100Mbps/Full Duplex failed DLK configuration: SPEED = 100 Mbps, DUPLEX = HALF Report Date:00-02-07 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
Use a valid combination of speed and duplex parameters on the card and Ethernetswitch for configuring a data link. An invalid combination may cause link degradationand unreliable behavior.
1358 - MSU discarded - too big after MTP conv.
• When ITUI or ITUN MSU, routed to ANSI or ITUN24 network, with SI less thanor equal to 5 is received on any card type where the original MSU is of sufficientsize that when the 14-bit point codes are converted to 24-bit point codes theresulting converted MSU will have SIF greater than 272 bytes.
• When ITUI or ITUN MSU, routed to ANSI or ITUN24 network, with SI rangingfrom 6 to 15 is received on any non-IP card type where the original MSU is ofsufficient size that when the 14-bit point codes are converted to 24-bit point codesthe resulting converted MSU will have SIF greater than 272 bytes. The MSU willbe discarded even if the outbound linkset is on IP card type and Large MSUSupport is enabled (Large MSU for IP Sig, Feature P/N 893018401) because
UIMs
3-242 EAGLE Unsolicited Alarm and Information Messages Reference
conversion is performed on the inbound card, so both the inbound and outboundcards must be able to support MSU greater than 272 bytes.
• When ITUI or ITUN MSU, routed to ANSI or ITUN24 network, with SI rangingfrom 6 to 15 is received on any IP card type where the original MSU is of sufficientsize that when the 14-bit point codes are converted to 24-bit point codes theresulting converted MSU will have SIF greater than 4095 bytes.
Example
0055.1358 CARD 1113 INFO MSU discarded - too big after MTP conv. LEN=50 SIO=04 OPC= 016-032-048 DPC= 032-032-048 DATA=01 02 03 04 05 06 07 08 09 0a 0b 0c 0d 0e 0f 10 11 12 13 14 15 16 17 18 19 1a 1b 1c LSN=ls211 Report Date:12-12-15 Time:11:03:11;
Note: The length of the MSU (for example, LEN=50) includes the length ofthe SIF plus some other parameters. The length of these other parametersvaries depending on the protocol managed by the LIM card issuing the UIM.
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action required.
1359 - SCCP Looping Detected
When a SCCP Looping condition is found, the mode of operation of the loopset will benotify or discard (based on provisioning). The mode of operation either only notifiesthe user (via this UIM), or notifies the user (via this UIM) and discards the MSU. Thedata shown in the output will be from the original MSU, before any GTT modificationswere applied to it.
A hop counter violation message is also sent by EAGLE to the UDTS. The messageindicates either ANSI or ITU Networks based on the provisioned GTT Translationpoint code type.
Example
nbsa01 12-01-23 19:41:10 BRA EAGLE5 41.1.1-62.67.1 0527.1359 CARD 3217 INFO SCCP Looping Detected SIO=83 OPC= 000-004-666 DPC= 000-006-500 SCCP MSG TYPE=09 CDPA: NI=0 RI=0 GTI=04 SSNI=1 PCI=0 TT=000 NP=01 NAI=004 ADDR=554197388383 PC=-------------- SSN=008 CGPA: NI=0 RI=0 GTI=04 SSNI=1 PCI=0 TT=000 NP=01 NAI=004 ADDR=551181134001 PC=-------------- SSN=008 LSN=ylrjo1 GTTSETIDX=(0) Report Date:12-01-23 Time:19:41:00
Alarm Level: No alarm condition. The message is informational only.
UIMs
UAM and UIM Troubleshooting Procedures 3-243
Recovery
Analysis of measurements and messages is required to ensure messages are correctlybeing discarded.
Note: Entering the wrong data in the SCCP Loop Table and/or incorrectlyconnecting a GTT translation with a particular SCCP Loop Table entry couldresult in unwanted traffic loss.
Refer to the Commands Manual for more information using ENT/CHG/DEL/RTRV-LOOPSET commands.
1. Remove invalid or unwanted entries from the SCCP Loop Tables.
2. Create a valid SCCP Loop Table entry for a GTT translation if the available tablesare valid for other translations, but not the one in error.
3. Set the "notify only" mode until confidence is gained in the EAGLE SCCP LoopTables, this is also the recommended setting for initial provisioning with asubsequent change.
4. Periodic auditing of UIMs to ensure that valid messages are not being discarded.
1360 - Inv SR-5129 msg rcvd, Bad Src.
An SR-5129 message was received with a bad source name in the message header.
Example
station1234 06-12-21 16:28:08 EST Rel 37.5.0-58.12.0 0020.1360 SYSTEM INFO Inv SR-5129 msg rcvd, Bad Src. Terminal = 17 Name = SNAMNJCCSM1YSA701 Report Date:06-12-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1361 - Inv SR-5129 msg rcvd, Bad Dst.
An SR-5129 message was received with a bad destination name in the message header.
Example
station1234 06-12-21 16:28:08 EST Rel 37.5.0-58.12.0 0020.1361 SYSTEM INFO Inv SR-5129 msg rcvd, Bad Dst. Terminal = 17 Name = SNAMNJCCSM1YSA701 Report Date:06-12-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
UIMs
3-244 EAGLE Unsolicited Alarm and Information Messages Reference
1362 - Inv SR-5129 msg rcvd, Bad Ver.
An SR-5129 message was received with a bad version in the message header.
Example
station1234 06-12-21 16:28:08 EST Rel 37.5.0-58.12.0 0020.1362 SYSTEM INFO Inv SR-5129 msg rcvd, Bad Ver. Terminal = 17 Ver = xxxx Report Date:06-12-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1363 - SR-5129 Err Msg rcvd Err Code 1(Bad Src)
An SR-5129 Error Message received with Error Code as 1 (Bad Source).
Example
station1234 06-12-21 16:28:08 EST Rel 37.5.0-58.12.0 0020.1363 SYSTEM INFO Inv SR-5129 Err Msg rcvd Err Code 1(Bad Src) Terminal = 17 Report Date:06-12-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1364 - SR-5129 Err Msg rcvd Err Code 2(Bad Dst)
An SR-5129 Error Message received with Error Code as 2 (Bad Destination).
Example
station1234 06-12-21 16:28:08 EST Rel 37.5.0-58.12.0 0020.1364 SYSTEM INFO Inv SR-5129 Err Msg rcvd Err Code 2(Bad Dst) Terminal = 17 Report Date:06-12-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1365 - SR-5129 Err Msg rcvd Err Code 3(Bad Ver)
An SR-5129 Error Message received with Error Code as 3 (Bad Version).
Example
UIMs
UAM and UIM Troubleshooting Procedures 3-245
station1234 06-12-21 16:28:08 EST Rel 37.5.0-58.12.0 0020.1365 SYSTEM INFO Inv SR-5129 Err Msg rcvd Err Code 3(Bad Ver) Terminal = 17 Report Date:06-12-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1366 - SR-5129 Err Msg rcvd Err Code Other
An SR-5129 Error Message received with Error Code other than 1, 2 and 3.
Example
station1234 06-12-21 16:28:08 EST Rel 37.5.0-58.12.0 0020.1366 SYSTEM INFO Inv SR-5129 Err Msg rcvd Err Code Other Terminal = 17 Report Date:06-12-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1367 - SOIP connection failed.
Failed to start SOIP connection.
Example
station1234 06-12-21 16:28:08 EST Rel 37.5.0-58.12.0 0009.1367 SYSTEM INFO SOIP connection failed. Terminal=17 IPADDR=192.168.57.52 PORT = 2336 Report Date:06-12-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1368 - Inv SR-5129 msg rcvd, Other
An SR-5129 Message Received with error other than Bad Source Name, BadDestination Name and Bad Version in the Message Header.
Example
station1234 06-12-21 16:28:08 EST Rel 37.5.0-58.12.0 0020.1368 SYSTEM INFO Inv SR-5129 msg rcvd, Other Terminal = 17 Report Date:06-12-21 Time:16:20:19
UIMs
3-246 EAGLE Unsolicited Alarm and Information Messages Reference
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1369 - ISUP IAM decode failed
An ISUP IAM decode failed with error other than Bad Source Name, Bad DestinationName, and Bad Version in the Message Header.
Example
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890 0020.1369 CARD 1201,A INFO ISUP IAM decode failed SIO=3 OPC=&&-001-001-001 DPC=&&-002-002-002 DATA=26 80 03 09 0e 06 09 00fe 08 50 55 43 00 LSN=LS0032
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1370 - ISUP IAM Cld Pty decode failed
An ISUP IAM Cld Pty decode failed with error other than Bad Source Name, BadDestination Name and Bad Version in the Message Header.
Example
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890 0020.1370 CARD 1201,A INFO ISUP IAM Cld Pty decode failed SIO=3 OPC=&&-001-001-001 DPC=&&-002-002-002 DATA=26 80 03 09 0e 06 09 00fe 08 50 55 43 00 LSN=LS0032
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1371 - ISUP encode Failed
An ISUP encode failed with error other than Bad Source Name, Bad Destination Nameand Bad Version in the Message Header.
Example
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890 0020.1371 CARD 1201,A INFO ISUP encode failed SIO=3 OPC=&&-001-001-001 DPC=&&-002-002-002 DATA=26 80 03 09 0e 06 09 00fe 08 50 55 43 00 LSN=LS0032
UIMs
UAM and UIM Troubleshooting Procedures 3-247
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1372 - SLTC Failure-SLTM not sent, Invalid SIO
The EAGLE attempted to send SLTM with SIO=2 for ITU APC.
Example
RLGHNCXA21W 00-02-07 12:01:43 EST EAGLE 37.0.01230.1372 CARD 1201,A INFO SLTC Failure-SLTM not sent, Invalid SIO ADJ PC=001-001-001 SLC=02 LEN=0f DATA=01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Report Date:00-02-07 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
Change the sltset corresponding to the link/port to the one that has sio=1 (RegularSLTM message).
Note: Special maintenance messages are not supported for ITU PCs.
1373 - TFC Generated for Congested Link
Implementation of auto decrementing of congestion abatement is multicast to all MTPcards (SRC and DEST).
In both ANSI and ITU networks, UIM 1373 indicates the level of congestion; forexample, CONG STATUS=001 is a lower level of congestion than CONG STATUS=003(the highest level of congestion).
For M3UA links, signaling congestion (SCON) network-management messages alsoreport congestion:
• In an ANSI network, the value in the SCON always matches the value in UIM1373.
• In a non-ANSI (ITU) network, SCON messages report only 0 (not congested) or 1(congested), so the congestion value reported in UIM 1373 can differ from thevalue in the SCON. For example, if UIM 1373 reports CONG STATUS=002 orCONG STATUS=003, then the value in the related SCON will be 1 (not 2 or 3).
Example
station1234 02-07-21 16:28:08 EST Rel 37.0.0 -46.12.0 8441.1373 CARD 1101,A INFO TFC Generated for Congested Link DPC= 001-115-000 CPC= 008-001-001 CONG SLK: 1305,A3 CONG STATUS=001 Report Date:07-01-05 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. Use local troubleshooting procedures to determine the cause for congestion.
UIMs
3-248 EAGLE Unsolicited Alarm and Information Messages Reference
1374 - SMS B-Party address decode failed
An error was detected during decode of SMS message destination address.
Example
tekelecstp 02-03-20 07:40:50 EST EAGLE 39.1.0-61.4.0 6815.1374 CARD 1103 INFO SMS B-Party Address decode failed SIO=83 OPC= 002-002-001 DPC= 009-008-007 CDPA: AI=8b SSN=002 TT=006 ADDR=110000 CGPA: AI=43 PC= 002-002-001 SSN=002 DATA=49 e2 47 c7 04 47 04 25 1e e8 3f e9 3d cf 01 e9 d1 02 09 35 f2 34 9f 69 01 00 9f 74 02 00 00 89 LSN=ls221 Report Date:02-03-20 Time:07:40:50
Alarm Level: No alarm condition. The message is informational only.
Recovery
The message should be analyzed to determine the error, and the originating nodeshould be contacted to send corrected message.
When processing MSU for SMS MO, this UIM is generated when one of the followingoccurs:
• Mandatory SM-RP-UI parameter is absent from the MO ForwardSM message.
• The TPDU type is SMS-SUBMIT and the parameter length is less then 4 + numberof digit bytes specified in the number of digit field.
• The TPDU type is SMS-COMMAND and the parameter length is less then 7 +number of digit bytes specified in the number of digit field.
• Number of digits is 0 or greater than 20.
1375 - SMS B-party Failed to modify TCAP MSU
The formatted outbound digit string length generated by SMS NP for encoding theTCAP message exceeded system limits.The formatted outbound digit string lengthgenerated by SMS NP or MO SMS B-Party Routing for encoding the TCAP messageexceeded system limits.
Example
tekelecstp 02-03-20 07:40:50 EST EAGLE 39.1.0-61.4.0 6815.1375 CARD 1103 INFO SMS B-party Failed to modify TCAP MSU SIO=83 OPC= 002-002-001 DPC= 009-008-007 CDPA: AI=8b SSN=002 TT=006 ADDR=110000 CGPA: AI=43 PC= 002-002-001 SSN=002 DATA=49 e2 47 c7 04 47 04 25 1e e8 3f e9 3d cf 01 e9 d1 02 09 35 f2 34 9f 69 01 00 9f 74 02 00 00 89 LSN=ls221 Report Date:02-03-20 Time:07:40:50
Alarm Level: No alarm condition. The message is informational only.
UIMs
UAM and UIM Troubleshooting Procedures 3-249
Recovery
The message and outbound digits formatting options should be analyzed to determinethe error and the originating node or the requested outbound digit formatting optionshould be modified to correct the encoding error.
This UIM is generated when processing MSU for SMS MO and TCAP message neededto be expanded to accommodate new digits and either
• New SM-RP-UI parameter length exceeds 127 digits.
• The length of new parameter sequence, Invoke component, component portion orTCAP package exceeds 127 bytes.
• The SCCP user data length (TCAP payload size) exceeds 255 bytes.
• The MSU length exceeds 279 bytes.
1376 - SMS Failed to modify B-Party digits
During processing of SMS message, the formatted outbound digit string lengthexceeded limit for number of digits.
This message is raised when:
• During processing of SMS message, the formatted outbound digit string lengthexceeded limit for number of digits.
• For MO SMS B-Party routing, AMGTT data provisioned in the GTT Table entrycorresponding to MAP B-Party number is used to modify MAP B-Party digits. Ifoutbound length exceeds 20 or becomes less than 0.
Example
tekelecstp 02-03-20 07:40:50 EST EAGLE 39.1.0-61.4.0 6815.1376 CARD 1103 INFO SMS Failed to modify B-Party digits SIO=83 OPC= 002-002-001 DPC= 009-008-007 CDPA: AI=8b SSN=002 TT=006 ADDR=110000 CGPA: AI=43 PC= 002-002-001 SSN=002 DATA=49 e2 47 c7 04 47 04 25 1e e8 3f e9 3d cf 01 e9 d1 02 09 35 f2 34 9f 69 01 00 9f 74 02 00 00 89 LSN=ls221 Report Date:02-03-20 Time:07:40:50
Alarm Level: No alarm condition. The message is informational only.
Recovery
The message and the digit format provisioning should be analyzed to determine theerror and the originating node or the requested outbound digit formatting optionshould be modified to correct the encoding error. For MO SMS B-Party Routing,AMGTT data (NSDD/NPDD/NSDS/NPDS) provisioned in GTT entry correspondingto MAP B-Party number should be modified to correct the encoding error.
This UIM is generated when SMS NP or MO SMS B-Party Routing feature generatedan outbound digit string for encode in TCAP message, which exceeded 20 digits inlength or is less than 0 digits in length forcing SMS NP/MO SMS B-Party Routing toroute original MSU.
UIMs
3-250 EAGLE Unsolicited Alarm and Information Messages Reference
1378 - Inh VFlex SS request already outstanding
A second attempt to inhibit the V-Flex subsystem has been made while the first is stillbeing processed. The second attempt will be ignored.
Example
tekelecstp 07-03-09 12:01:43 EST EAGLE 37.6.05061.1378 SYSTEM INFO Inh VFlex SS request already outstanding
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1379 - Failure Inhibiting VFlex SS
The attempted inhibit of the V-Flex subsystem failed. A response SOG was notreceived from the mate.
Example
tekelecstp 07-03-09 12:01:43 EST EAGLE 37.6.05061.1379 SYSTEM INFO Failure Inhibiting VFlex SS
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1380 - VFLEX: No RN digits provisioned
The digits in the VMS at the requested VMRN index were not provisioned. Theprovisioning information for the VMS ID accessed via the MSU information should beverified.
Example
RLGHNCXA21W 07-07-21 12:01:43 EST EAGLE 37.6.0 0002.1380 SYSTEM INFO VFlex: RN is not provisioned SIO=03 OPC=001-001-001 DPC=002-002-002 SCCP MSG TYPE=04 CDPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1 TT=250 NP=04 NAI=010 ADDR=1234567890901 PC=003-003-003 SSN=005 CGPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1 TT=100 NP=07 NAI=012 ADDR=012345677890 PC=001-001-001 SSN=004 LSN=ABCD123 GTTSET=3 203 46 Report Date:07-07-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
Verify the VMS ID accessed via the MSU information.
UIMs
UAM and UIM Troubleshooting Procedures 3-251
1381 - VFlex: CD entry not found
The call decision table entry matching the incoming MSU criteria is not found. Calldecision tree provisioning should be updated.
Example
RLGHNCXA21W 07-07-21 12:01:43 EST EAGLE 37.6.0 0002.1381 SYSTEM INFO VFlex: CD entry not found SIO=03 OPC=001-001-001 DPC=002-002-002 SCCP MSG TYPE=04 CDPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1 TT=250 NP=04 NAI=010 ADDR=1234567890901 PC=003-003-003 SSN=005 CGPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1 TT=100 NP=07 NAI=012 ADDR=012345677890 PC=001-001-001 SSN=004 LSN=ABCD123 GTTSET=3 203 46 Report Date:07-07-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
Call decision tree provisioning should be updated.
1382 - Too many digits for DRA parameter
Too many digits in the DRA parameter to encode.
Example
RLGHNCXA21W 07-07-21 12:01:43 EST EAGLE 37.6.0 0002.1382 SYSTEM INFO Too many digits for DRA parameter SIO=03 OPC=001-001-001 DPC=002-002-002 SCCP MSG TYPE=04 CDPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1 TT=250 NP=04 NAI=010 ADDR=1234567890901 PC=003-003-003 SSN=005 CGPA: NI=1 RI=0 GTI=04 SSNI=0 PCI=1 TT=100 NP=07 NAI=012 ADDR=012345677890 PC=001-001-001 SSN=004 LSN=ABCD123 GTTSET=3 203 46 Report Date:07-07-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
Decrease the number of RN digits or modify the querying node to send fewer digits inDN.
1383 - SLTC Failed: No route to APC on linkset
An SLTC message is sent/received for a linkset that is not in the route-set of its APC.
Example
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890 8606.1383 CARD 1105,B INFO SLTC Failed: No route to APC on linkset
UIMs
3-252 EAGLE Unsolicited Alarm and Information Messages Reference
ADJ PC= 002-14-00 SLC=000 LEN=002 DATA=11 77 Report Date:02-04-01 Time:17:40:42
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1392 - IDPRCDPN(X) NPP SERVICE is OFF
The status of the IDPRCDPN(X) NPP service is OFF while processing an IDP message.
Example
1 2 3 4 5 6 7 8 12345678901234567890123456789012345678901234567890123456789012345678901234567890 tekelecstp 20-12-11 03:56:48 WET UNKNOWN ??.?.?-64.12.0 5090.1392 CARD 1105 INFO IDPRCDPN(X) NPP SERVICE is OFF Report Date:20-12-11 Time:03:56:48
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. Enter the following command to check the status of the IDPRCDPN(X) service:rtrv-npp-serv:srvn=idprcdpn:mode=full
The following is an example of a possible output.
rtrv-npp-serv:srvn=idprcdpn:mode=full tekelecstp 11-01-28 08:34:00 EST 43.0.0-63.51.0 rtrv-npp-serv:srvn=idprcdpn:mode=full Command entered at terminal #4. SERVICE STATUS SA PRECEDENCE FNAI NAI ------------------------------------------------------ idprcdpn off cdial 10 unkn 0 ccncchk 100 intl 4 cdpnnp 80 natl 3 lacck 60 nai1 none cgpnsvcrqd 60 nai2 none asdlkup 50 nai3 none grnlkup 50 cgpnasdrqd 50 cgpngrnrqd 50 inprtg 95 skgtartg 50 DELIMITERS dlma=none dlmb=none dlmc=none dlmd=none dlme=none dlmf=none dlmg=none dlmh=none dlmi=none dlmj=none dlmk=none dlml=none dlmm=none dlmn=none dlmo=none dlmp=none ;
UIMs
UAM and UIM Troubleshooting Procedures 3-253
2. Use the following command to enable the IDPRCGPN(X) NPP service: chg-npp-serv:srvn=idprcgpn:mode=full
This is an example of a possible output.
rtrv-npp-serv:srvn=idprcgpn:mode=full tekelecstp 11-01-28 08:37:46 EST 43.0.0-63.51.0 rtrv-npp-serv:srvn=idprcgpn:mode=full Command entered at terminal #4. SERVICE STATUS SA PRECEDENCE FNAI NAI ------------------------------------------------------ idprcgpn off cdial 10 unkn 0 cgpnnp 80 intl 4 asdlkup 50 natl 3 grnlkup 50 nai1 none blklstqry 90 nai2 none blklstrly 90 nai3 none cgpnrtg 70 inprtg 95 DELIMITERS dlma=none dlmb=none dlmc=none dlmd=none dlme=none dlmf=none dlmg=none dlmh=none dlmi=none dlmj=none dlmk=none dlml=none dlmm=none dlmn=none dlmo=none dlmp=none ;
1393 - IDPRCGPN NPP SERVICE is OFF
The status of the IDPRCGPN NPPservice is OFF while processing an IDP message.
Example
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890 tekelecstp 20-12-11 03:56:48 WET UNKNOWN ??.?.?-63.33.0 5090.1392 CARD 1105 INFO IDPRCDPN NPP SERVICE is Off Report Date:20-12-11 Time:03:56:48
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. Enter the following command to check the status of the IDPRCGPN service: rtrv-npp-serv:srvn=idprcgpn
The following is an example of a possible output.
tekelecstp 08-06-17 11:54:09 EST 39.0.0 rtrv-npp-serv:srvn=idprcgpn Command entered at terminal #4. SERVICE STATUS FNAI NAI SA PRECEDENCE _________________________________________________________ idprcgpn off unkn 0 cgpnnp 100 intl 4 natl 3 nai1 none
UIMs
3-254 EAGLE Unsolicited Alarm and Information Messages Reference
nai2 none nai3 none;
2. Use the following command to enable the IDPRCDPN service: chg-npp-serv:srvn=idprcgpn:status=ON
1394 - Flushing undelivered MSUs
The destination EAGLE card for an SS7 message is not reachable by the originationEAGLE card and the dynamic database is not updated to reflect the unreachablestatus.
Example
tekelecstp 02-01-05 20:39:14 MST EAGLE 41.0 0010.1394 CARD 1108 INFO Flushing undelivered MSUs Card List: 1101, 1201, 1302, 2103, 2204 LSN=lg1104a0 Report Date:02-01-05 Time:20:39:14;
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. Enter the following command to check the IMT bus status for both the source anddestination card.
rept-stat-card:loc=x:mode=full
wherex is the card location. The source card is identified in the message. Thedestination card can be obtained from the linkset name in UIM.
Note: There could be several cards involved with the linkset name and thusthey all should be checked.
Following is an example of the possible output using card 1106:
RLGHNCXA21W 08-01-21 12:01:43 EST EAGLE 38.0.0 CARD VERSION TYPE APPL PST SST AST 1106 021-101-000 TSM SCCP IS-NR Active ----- ALARM STATUS = No Alarms. IMT VERSION = 021-001-000 PROM VERSION = 021-001-000 IMT BUS A = Conn IMT BUS B = Conn CLOCK A = Active CLOCK B = Idle CLOCK I = Idle MBD BIP STATUS = valid DB STATUS = valid DBD MEMORY SIZE = 64M SCCP SERVICE = 1201, 1214, 1215, 1217, 1102 SCCP % OCCUP = 0% SLK A PST = OOS-MT LS=ls11234567 CLLI= SLK B PST = OOS-MT LS=ls11345678 CLLI= SNM TVG RESULT = 24 hr: ------, 5 min: ------ SLAN TVG RESULT = 24 hr: ------, 5 min: ------
UIMs
UAM and UIM Troubleshooting Procedures 3-255
SCCP TVG RESULT = 24 hr: ------, 5 min: ------ Command Completed.
2. Make sure the cards are correctly connected to both A and B buses of the IMT.
1395 - Inh ATINPQ SS request alrdy outstanding
A second attempt to inhibit the ATINPQ subsystem has been made while the first isstill being processed. The second attempt will be ignored.
Example
station1234 06-12-21 16:28:08 EST Rel 39.2.0 0020.1395 CARD 1106 INFO Inh ATINPQ SS request alrdy outstanding
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1396 - Failure Inhibiting ATINPQ SS
The attempted inhibit of the ATINPQ subsystem failed. A response SOG was notreceived from the mate.
Example
station1234 06-12-21 16:28:08 EST Rel 39.2.0 0020.1396 CARD 1106 INFO Failure Inhibiting ATINPQ SS
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1407 - Unexpected SI in TIF Stop Action
An MSU is received by TIF/TIF2/TIF3 stop action that is not ISUP. MSUs delivered toa TIF stop action that are not ISUP (SI=5) or TUP (SI=4) shall be routed withoutmodification.
Example
RLGHNCXA21W 09-09-21 16:20:19 GMT EAGLE5 39.2.0 0017.1407 CARD 1103,A INFO Unexpected SI in TIF Stop Action SIO=08 OPC=001-001-001 DPC=s-002-002-002 DATA=12 34 56 78 90 12 34 56 78 90 12 34 56 78 90 12 34 56 78 90 12 34 56 78 12 34 SR=scrb LSN=ABCD123 Report Date:09-09-21 Time:16:20:19
Legend
DATAInformation from the upper layers of SCCP management
UIMs
3-256 EAGLE Unsolicited Alarm and Information Messages Reference
DPCDestination point code
LSNLinkset name. The name must be unique.
OPCOrigination point code
SIOService information octet
SRScreening reference name
Alarm Level: No alarm condition. The message is informational only.
Recovery
The TIF Support of TUP feature is not turned on.
1408 - TIF: Modified MSU too large to route
The MSU is too large to transmit after modification (>273 bytes from SIO onward). Theoriginal MSU is routed without modification.
Example
RLGHNCXA21W 09-09-21 16:20:19 GMT EAGLE5 39.2.0 0017.1408 CARD 1103,A INFO TIF: Modified MSU too large to route SIO=03 OPC=001-001-001 DPC=002-002-002 DATA=26 80 03 09 0e 06 09 00 fe 08 50 55 05 43 00 00 00 00 00 LSN=ABCD123 Report Date:09-09-21 Time:16:20:19
Legend
DATAInformation from the upper layers of SCCP management
DPCDestination point code
LSNLinkset name. The name must be unique.
OPCOrigination point code
SIOService information octet
SRScreening reference name
Alarm Level: No alarm condition. The message is informational only.
UIMs
UAM and UIM Troubleshooting Procedures 3-257
Recovery
No action necessary.
1410 - MOSMS: Migrated Subscriber with no entity
There is no entity defined in the RTDB for the migrated subscriber. The subscriber isfound migrated and the migration prefix has to be the entity resulted from RTDBlookup.
Example
tekelecstp 02-03-20 07:40:50 EST EAGLE 40.1 6815.1410 CARD 1103 INFO MOSMS: Migrated Subscriber with no entity SIO=83 OPC= 002-002-001 DPC= 009-008-007 CDPA: AI=8b SSN=002 TT=006 ADDR=110000 CGPA: AI=43 PC= 002-002-001 SSN=002 DATA=49 e2 47 c7 04 47 04 25 1e e8 3f e9 3d cf 01 e9 d1 02 09 35 f2 34 9f 69 01 00 9f 74 02 00 00 89 LSN=ls221 Report Date:02-03-20 Time:07:40:50
Alarm Level: No Alarm condition. Message is for information only.
Recovery
Ensure the subscriber has an Entity in the Database, or change MOIGMPFX value ofIS41SMSOPTS Table.
1411 - TIF CgPN NS Failure: CC mismatch in DN
A CC mismatch in DN occurred during TIF framework conversion. The CgPN will notbe modified.
Example
tekelecstp 02-03-20 07:40:50 EST EAGLE 41.0 0226.1411 CARD 1101 INFO TIF CgPN NS Failure: CC mismatch in DN International CGPN: 911111012345678 EPAP DN : 899111632226337 Report Date:08-09-10 Time:16:20:19
Alarm Level: No Alarm condition. Message is for information only.
Recovery
Verify the Public and Private DNs CC match. If the CCs do not match, reconcile theissue within the subscriber database.
1416 - MAP Missing Mandatory Parameters
MOSMS Feature could not decode the GSM MAP message, since there are missingmandatory parameters in the TCAP portion of the message. e.g. SM-RP-UI or SM-RP-OA.
Example
UIMs
3-258 EAGLE Unsolicited Alarm and Information Messages Reference
tekelecstp 02-03-20 07:40:50 EST EAGLE 40.1 6815.1416 CARD 1103 INFO MAP Missing Mandatory Parameters SIO=83 OPC= 002-002-001 DPC= 009-008-007 CDPA: AI=8b SSN=002 TT=006 ADDR=110000 CGPA: AI=43 PC= 002-002-001 SSN=002 DATA=49 e2 47 c7 04 47 04 25 1e e8 3f e9 3d cf 01 e9 d1 02 09 35 f2 34 9f 69 01 00 9f 74 02 00 00 89 LSN=ls221 Report Date:02-03-20 Time:07:40:50
Alarm Level: No Alarm condition. Message is for information only.
Recovery
Ensure the message contains all mandatory parameters.
1417 - PublicKey doesn’t match known-host file
This message indicates that the SSH public key that is exchanged between the host andserver has changed. This could be due to a legitimate configuration change on theserver, or it could be caused by a security breach, such as a man-in-the-middle attack.
If strict-host-key-checking is in effect, the connection will be rejected. Otherwise, thenew key will be automatically added to the known-host file
Example
RLGHNCXA21W 13-07-30 21:18:09 EDT EAGLE5 45.0.0-64.70.10130.1417 CARD 1113 INFO PublicKey doesnt match known-host fileFTP Server IP Address = xxx.xxx.xxx.xxx;
Alarm Level: No alarm condition. The message is informational only.
Recovery
Contact the server system administrator to determine if the host key change islegitimate.
1424 - IMT A [B] requested to re-align at LOW [HIGH] Rate
This message is issued when a rate change request is sent by the OAM to the HIPR2cards on a particular bus (to re-align at the requested rate). The HIPR2 cards willinitiate the alignment protocol on receiving the request.
Example
RLGHNCXA21W 09-02-07 12:01:43 EST EAGLE 41.1.0 0023.1424 CARD 1115 INFO IMT A requested to re-align at HIGH Rate Report Date:09-02-07 Time:12:01:43
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
UIMs
UAM and UIM Troubleshooting Procedures 3-259
1425 - SMS A-party Address decode failed
Decoding fields of the SMS_OOA parameter of IS41 SMDPP message failed.
Example
tekelecstp 02-03-20 07:40:50 EST EAGLE 40.1 6815.1425 CARD 1103 INFO SMS A-party Address decode failed SIO=83 OPC= 002-002-001 DPC= 009-008-007 CDPA: AI=8b SSN=002 TT=006 ADDR=110000 CGPA: AI=43 PC= 002-002-001 SSN=002 DATA=49 e2 47 c7 04 47 04 25 1e e8 3f e9 3d cf 01 e9 d1 02 09 35 f2 34 9f 69 01 00 9f 74 02 00 00 89 LSN=ls221 Report Date:02-03-20 Time:07:40:50
Alarm Level: No Alarm condition. Message is for information only.
Recovery
Ensure that SMDPP message contains properly formatted SMS_OOA parameter.
1426 - S-Port: Missing GRN for srvc prtd subs
Service Portability required RTDB data “GRN” to format outbound digits, which wasnot found.
Example 1
0017.1042 CARD 1103,A INFO S-Port: Missing GRN for srvc prtd subs SIO=03 OPC=001-001-001 DPC=002-002-002 INCM DN: 4605500 COND DN: 19194605500 LSN=ABCD123
Example 2
6850.1426 CARD 1103 INFO S-Port: Missing GRN for srvc prtd subs SIO=83 OPC= 002-002-001 DPC= 009-008-007 CDPA: AI=8b SSN=002 TT=006 ADDR=987654 CGPA: AI=09 PC=-------------- SSN=003 INCM DN: 4605500 COND DN: 19194605500 LSN=ABCD123
Alarm Level: No alarm condition. The message is informational only.
Recovery
Verify that a GRN has been provisioned for the conditioned DN (specified in theCOND DN field in the UIM output) in EPAP.
1427 - IAR CdPN parameter invalid or not found
This message is issued when the IAR Base feature cannot find a CdPN parameterwithin a message, when it cannot decode the parameter after it finds it, or when theparameter does not contain the required information in a usable format.
UIMs
3-260 EAGLE Unsolicited Alarm and Information Messages Reference
Example
RLGHNCXA21W 09-07-21 16:20:19 EST EAGLE 41.1.0 0002.1427 CARD 1113 INFO IAR CdPN parameter invalid or not found Report Date:09-07-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1428 - IAR CgPN parameter invalid or not found
This message is issued when the IAR Base feature cannot find the CgPN parameterwithin a message, when it cannot decode the parameter after it finds it, or when theparameter does not contain the required information in a usable format.
Example
RLGHNCXA21W 09-07-21 16:20:19 EST EAGLE 41.1.0 0002.1428 CARD 1113 INFO IAR CgPN parameter invalid or not found Report Date:09-07-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1429 - IAR TRIGTYPE invalid or not found
This message is issued when the IAR Base feature cannot find the TRIGTYPEparameter within a message, when it cannot decode the parameter after it finds it, orwhen the parameter does not contain the required information in a usable format.
Example
RLGHNCXA21W 09-07-21 16:20:19 EST EAGLE 41.1.0 0002.1429 CARD 1113 INFO IAR TRIGTYPE invalid or not found Report Date:09-07-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1430 - IAR CdPN parameter encoding failed
This message is issued when the IAR Base feature cannot encode the message aftermodifying its CdPN parameter. One way that this can occur without invalid data iswhen a CdPN parameter length increases, and the containing message grows toolarge.
Example
RLGHNCXA21W 09-07-21 16:20:19 EST EAGLE 41.1.0 0002.1430 CARD 1113 INFO IAR CdPN parameter encoding failed
UIMs
UAM and UIM Troubleshooting Procedures 3-261
Report Date:09-07-21 Time:16:20:19
Alarm Level: No Alarm condition. Message is for information only.
Recovery
No action necessary.
1431 - IAR CgPN parameter encoding failed
This message is issued when the IAR Base feature cannot encode the message aftermodifying its CgPN parameter. One way that this can occur without invalid data iswhen a CgPN parameter length increases, and the containing message grows toolarge.
Example
RLGHNCXA21W 09-07-21 16:20:19 EST EAGLE 41.1.0 0002.1431 CARD 1113 INFO IAR CgPN parameter encoding failed Report Date:09-07-21 Time:16:20:19
Alarm Level: No Alarm condition. Message is for information only.
Recovery
No action necessary.
1433 - AIQ: Inhibit request already pending
An inh-map-ss command is already entered and queued.
Example
RLGHNCXA21W 00-02-10 12:01:43 EST EAGLE 42.0.00014.1433 SYSTEM INFO AIQ: Inhibit request already pending
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1434 - AIQ: Failure Inhibiting SS
The inh-map-ss command did not take the AIQ subsystem off-line.
Example
RLGHNCXA21W 00-02-10 12:01:43 EST EAGLE 42.0.00014.1434 SYSTEM INFO AIQ: Failure Inhibiting SS
Alarm Level: No alarm condition. The message is informational only.
Recovery
Enter the inh-map-ss command with the force parameter.
1435 - AIQ: TriggerType not provisioned
This message indicates that the AIQ subsystem received an AIQ message where thevalue of the TriggerType parameter is not provisioned in the AIQOPTS table.
UIMs
3-262 EAGLE Unsolicited Alarm and Information Messages Reference
Example
5193.1435 CARD 1105 INFO AIQ: TriggerType not provisioned SIO=83 OPC= 001-001-001 DPC= 009-008-007 CDPA: AI=cb SSN=014 TT=004 ADDR=9873946354 CGPA: AI=cb PC= 001-001-001 SSN=014 DATA=3f e2 3d c7 04 00 01 02 03 e8 35 e9 33 cf 01 2a d1 02 09 40 f2 29 81 07 00 00 00 00 00 00 00 84 LSN=ls1 Report Date:20-08-29 Time:02:55:22
Alarm Level: No alarm condition. The message is informational only.
Recovery
Ensure the AIQ message’s TriggerType parameter value is one of those provisioned inthe AIQOPTS table.
1436 - AIQ: Unsupported Digits(Dialed) length
This message indicates that the AIQ subsystem received an AIQ message where thelength of the Digits(Dialed) parameter is outside of the range provisioned in theAIQOPTS table.
Example
0643.1436 CARD 1105 INFO AIQ: Unsupported Digits(Dialed) length SIO=83 OPC= 001-001-001 DPC= 009-008-007 CDPA: AI=cb SSN=014 TT=004 ADDR=9873946354 CGPA: AI=cb PC= 001-001-001 SSN=014 DATA=3f e2 3d c7 04 00 01 02 03 e8 35 e9 33 cf 01 2a d1 02 09 40 f2 29 81 07 00 00 00 00 00 00 00 84 LSN=ls1 Report Date:20-08-29 Time:03:04:25
Alarm Level: No alarm condition. The message is informational only.
Recovery
Ensure the AIQ message’s Digits(Dialed) parameter length is within the rangeprovisioned in the AIQOPTS table.
1437 - IMT [A|B]: Rate change not initiated
This message is issued when the IMT Rate change could not proceed due to bus beingin alarming state.
Example
RLGHNCXA21W 09-02-07 12:01:43 EST EAGLE 41.1.0 0023.1437 CARD 1115 INFO IMT A: Rate change not initiated Report Date:09-02-07 Time:12:01:43
Alarm Level: No alarm condition. The message is informational only.
Recovery
UIMs
UAM and UIM Troubleshooting Procedures 3-263
Although no action is required, this message can serve as a notification to verify statusof the IMT bus and to start recovery procedures if needed.
1. Enter the rept-stat-imt command to verify the status of the IMT bus.
2. Replace any faulty cards with a new HIPR2 card.
3. Contact the My Oracle Support (MOS) for more information.
1439 - SIP card exceeded threshold TPS
The alarm indicates that the SIP card has reached maximum TPS.
Example
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890 xxxx.1439 CARD 1106 INFO SIP card exceeded threshold TPS Report Date:13-09-03 Time:18:57:35
Alarm Level: No alarm condition. The message is informational only.
Recovery
Traffic must be reduced to the SIP card. Failure to reduce SIP card traffic may result intraffic or card failure.
1440 - G-Flex MLR: Op with bad MSISDN skipped
The G-Flex MLR Function encountered an MSISDN parameter that contains fewerthan 5 digits or more than 15 digits
Example
station1234 06-12-21 16:28:08 EST Rel 42.0.0 0020.1440 CARD 1106 INFO G-Flex MLR: Op with bad MSISDN skipped
Alarm Level: No alarm condition. The message is informational only.
Recovery
Abnormal length of the MSISDN indicates a configuration issue on the far-end node,which can be confirmed with a message trace.
1441 - IP Info mismatch, card reset required
The card stated in the message has an IP mismatch and must be reset. This occurswhen the database is updated and a manual reset must be performed for the newlyprovisioned values to be used.
The IP configuration commands support the MCAP locations when OAMHC isrunning. Usually these commands require the target card to be inhibited, however forMCAP locations, the command is expected to be run while the card is IS-NR. Sincethese commands result in a database update, they require the MCAP to be IS-NR.Once the database has been modified, manual reset of the card must be performed forthe newly provisioned values to be used. A notice is displayed to the user regardingthe reset requirement for an MCAP location. If the MCAP location is not reset, then a
UIMs
3-264 EAGLE Unsolicited Alarm and Information Messages Reference
UIM is displayed once every hour indicating that the card has an IP Mismatch andmust be reset.
Example
RLGHNCXA03W 10-01-11 16:20:19 EST EAGLE 42.0.0 0020.1441 CARD 1113 INFO Active OAM IP mismatch, 1113 reset req Report Date:10-01-11 Time:16:20:19
0020.1441 CARD 1113 INFO Standby OAM IP mismatch, 1115 reset req Report Date:10-01-11 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
Reset the card in the appropriate slot as specified in the message text.
1442 - Invalid EMP SCR Message Received
This UIM indicates that the EAGLE 5 ISS received and rejected an invalid ServiceConfiguration Request (SCR) EMP message. The UIM includes the IP address wherethe request originated and the reason the EAGLE 5 ISS rejected the SCR message.
Example
0020.1442 CARD 1106,A INFO Invalid EMP SCR Message Received MSG Length=6 REQ EMP Version=4 RSP EMP Version=4 REQ Transaction ID=123 RSP Transaction ID=123 IMF IP Address= 172.21.48.15 Reason=Invalid Message Length Report Date:10-02-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary if there is only one occurrence. If the condition continues, usethe information provided in the message to debug the problem.
1445 - LNP Day Meas. Discarded for LRN
This message is indicates that the Daily LNR measurement counts are incorrectbecause of discards due to provisioning.
Example
RLGHNCXA03W 10-01-11 16:20:19 EST EAGLE 42.0.0 0020.1015 CARD 1106 INFO LNP Day Meas. Discarded for LRN Report Date:02-07-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action required.
1449 - Binding Failed for screen set: <screen set name>
This UIM indicates a screen-set binding failure in Gateway Screening (GWS).
UIMs
UAM and UIM Troubleshooting Procedures 3-265
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 0023.1449 CARD 1105 INFO Binding Failed for screen set: ayyy Report Date:11-05-26 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
Refer to the UIM for the name of the failed screen set. The LIM or Service Module cardregenerates a binding request.
1450 - IDPRCDPN CDPN Encoding Failed
This UIM is raised if IDPRCDPN encoding fails.
Example
1 2 3 4 5 6 7 812345678901234567890123456789012345678901234567890123456789012345678901234567890 eagle4 02-03-06 14:31:03 MST UNKNOWN ??.?.?-64.19.0 9442.XXXX CARD 1105 INFO IDPR CDPN encoding failed SIO=03 OPC= 1-010-1 DPC= 1-001-1 CDPA: AI=0b SSN=051 TT=025 ADDR=9900112233 CGPA: AI=4a PC=-------------- SSN=051 INCM DN: 9992222226 COND DN: 9992222226 LSN=itu1 Report Date:02-03-06 Time:14:31:03
Alarm Level: No alarm condition. The message is informational only.
Recovery
One or more of following actions must be taken:
1. The Formatting Action list in the NPP Action Set that processed the IDP Querymust be corrected.
2. The data associated with DN in the RTDB must be corrected.
3. The message must have enough space for the CDPN parameter expansion.
1451 - IDPRCGPN CGPN Encoding Failed
This UIM is raised if IDPRCGPN encoding fails.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 9452.1451 CARD 1105 INFO IDPR CGPN encoding failed SIO=03 OPC= 1-010-1 DPC= 1-001-1 CDPA: AI=0b SSN=051 TT=025 ADDR=9900112233 CGPA: AI=4a PC=-------------- SSN=051 INCM DN: 9992222227 COND DN: 9992222227 LSN=itu1 Report Date:02-03-06 Time:14:37:31
UIMs
3-266 EAGLE Unsolicited Alarm and Information Messages Reference
Alarm Level: No alarm condition. The message is informational only.
Recovery
One or more of following actions must be taken:
1. The Formatting Action list in the NPP Action Set that processed the IDP Querymust be corrected.
2. The data associated with DN in the RTDB must be corrected.
3. The message must have enough space for the CGPN parameter expansion.
1452 - Invalid IP Address from SCTP Heartbeat Response
This UIM indicates an SCTP layer received a Heartbeat Response (HB) with a sourceIP address that did not match the IP address from where the original HB message wassent.
Example
1 2 3 4 5 6 7 8123456789012345678901234567890123456789012345678901234567890123456789012345678900388.1452 CARD 1308,A INFO SCTP HB ACK from unexpected IP address HB RESP IPADDR = 10.254.111.21 HB RESP PORT = 4002 HB INFO IPADDR = 10.254.111.21 HB INFO PORT = 4002 SNAME = sg1308b Report Date:12-07-10 Time:13:45:24
Alarm Level: No alarm condition. The message is informational only.
Recovery
Correct the IP network setup for the SCTP association.
1453 - EE Collection started
This UIM indicates collection has started on a network card when Eagle Eyes proper isin Active state.
Example
1 2 3 4 5 6 7 8123456789012345678901234567890123456789012345678901234567890123456789012345678900023.1453 CARD 1105 INFO Collection started on card
Alarm Level: No alarm condition. The message is informational only.
Recovery
None.
1454 - EE Collection end
This UIM indicates the collection ends when Eagle Eyes proper enters idle state.
UIMs
UAM and UIM Troubleshooting Procedures 3-267
Note: EAGLE may not output this UIM when Eagle Eye Collectiontermination is initiated by the system based on the set capture limit (SECLIM,PKTLIM, and KBLIM).
Example
1 2 3 4 5 6 7 8123456789012345678901234567890123456789012345678901234567890123456789012345678900023.1454 CARD 1105 INFO EE Collection end
Alarm Level: No alarm condition. The message is informational only.
Recovery
None.
1455 - EE Queue full, Packets Dropped
This UIM indicates the message queue on the GEDTI card is full; no more packets canbe enqueued..
Example
1 2 3 4 5 6 7 8123456789012345678901234567890123456789012345678901234567890123456789012345678900023.1455 CARD 1105 INFO EE Queue Full Packets Dropped
Alarm Level: No alarm condition. The message is informational only.
Recovery
None.
1456 - Hub Congested, Packets Dropped
This UIM indicates the message queue between the GEDTI and EEPC is full.
Example
1 2 3 4 5 6 7 8123456789012345678901234567890123456789012345678901234567890123456789012345678900023.1456 CARD 1105 INFO Hub Congested Packets Dropped
Alarm Level: No alarm condition. The message is informational only.
Recovery
None.
1457 - GEDTI Port Enabled
This UIM indicates the GEDTI port is enabled on the IPSM card.
Example
1 2 3 4 5 6 7 8123456789012345678901234567890123456789012345678901234567890123456789012345678909671.1457 CARD 1112 INFO GEDTI Port Enable PORT = 5555
UIMs
3-268 EAGLE Unsolicited Alarm and Information Messages Reference
Alarm Level: No alarm condition. The message is informational only.
Recovery
None.
1458 - GEDTI Port Disabled
This UIM indicates the GEDTI port is disabled on the IPSM card.
Example
1 2 3 4 5 6 7 8123456789012345678901234567890123456789012345678901234567890123456789012345678909642.1458 CARD 1112 INFO GEDTI Port Disabled PORT = 5555
Alarm Level: No alarm condition. The message is informational only.
Recovery
When the GEDTI port is enabled.
1459 - TCP Connection lost b/w IPSM and EEPC
This UIM indicates the TCP Connection between the IPSM card and network card hasbeen lost.
Example
1 2 3 4 5 6 7 8123456789012345678901234567890123456789012345678901234567890123456789012345678900023.1459 CARD 1105 INFO TCP Connection lost b/w IPSM and EEPC SESSION ID = 1
Alarm Level: No alarm condition. The message is informational only.
Recovery
When the TCP Connection is re-established.
1460 - GWS Duplicate Stop Action Failed
This message indicates the gateway screening (GWS) Duplicate and Route stop actionfailed to duplicate an incoming MSU.
Example
5347.1460 CARD 1103 INFO GWS Duplicate Stop Action Failed Report Date:13-10-10 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No further action is required.
1461 - Link status on card needs re-sync
This message indicates the Link status on the card needs to be re-synched and thesystem has initiated a re-synchronization.
UIMs
UAM and UIM Troubleshooting Procedures 3-269
Example
0020.1461 CARD 1106 INFO Link status on card needs re-sync Card=xxxx Port=xxx Report Date:02-07-21 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
1462 - EE not Configured
This message indicates the EE capture does not start when the network card undercapture is not configured as Eagle Eyes Proper.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 0023.1462 CARD 1105 INFO EE not Configured
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1463 - ENUM connection established
This message indicates the ENUM connection has come into IS-NR state.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 xxxx.1463 CARD 1463 INFO ENUM connection established Connection Name : enum1101 Report Date: 06-05-14 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1464 - ENUM connection terminated
This message indicates the ENUM connection has gone down.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 xxxx.1464 CARD 1464 INFO ENUM connection terminated Connection Name : enum1101 Report Date:06-05-14 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1466 - ENUM Dflt Prof & query type mismatch
The Default ENUM Profile response type and incoming query type do not match.
Example
UIMs
3-270 EAGLE Unsolicited Alarm and Information Messages Reference
12345678901234567890123456789012345678901234567890123456789012345678901234567890 xxxx.1466 CARD 1466 INFO ENUM Dflt Prof & query type mismatch Report Date: 06-05-14 Time:18:57:35
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1467 - ENUM msg decode failed
This message indicates an ENUM message validation has FAILED.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 xxxx.1467 CARD 1467,B INFO ENUM msg decode failed Reason: Response Recieved Header: QR(1) Domain: ---- IP : 10.248.13.3 QType : ---- Entity ID: ---- Report Date:06-05-14 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1468 - ENUM rcvd invalid msg
This message indicates the ENUM has received a query with unsupported fieldvalues.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 xxxx.1468 CARD 1468,B INFO ENUM rcvd invalid msg Reason: Invalid Domain Header: QR(0) Domain: e164.abcd IP : 10.248.13.3 QType : NAPTR(35) Entity ID: ---- Report Date: 06-05-14 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1469 - ENUM request rejected
This message indicates an ENUM request rejected is coming from invalid IP addresses.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 xxxx.1469 CARD 1469,B INFO ENUM request rejected
UIMs
UAM and UIM Troubleshooting Procedures 3-271
Reason: Unauthorized ENUM Client Header: ---- Domain: ---- IP : 10.248.13.9 QType : ---- Entity ID: ---- Report Date: 06-05-14 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1471 - ENUM matching prof for qry not found
This message indicates the ENUM Profile Table is missing an entry of a matchingENUM query type.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 xxxx.1471 CARD 1471,B INFO ENUM matching prof for qry not found Reason: Queried Response type not found Header: QR(0) Domain: e164.arpa IP : 10.248.13.3 QType : NAPTR(35) Entity ID: 123456 Report Date: 06-05-14 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1472 - SCTP Buffer full timer expired, Restart
This message indicates the SCTP Buffer full timer has expired and requires a restart.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 xxxx.1472 CARD 1104 INFO SCTP Buffer full timer expired, Restart Report Date: 06-05-14 Time:16:20:19
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1473 - Unable to connect to socket
This message indicates the EAGLE is unable to connect to the EAGLE ApplicationProcessor. Verify the IP configuration for connectivity to the far end.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 0002.1473 CARD 1113 INFO Unable to connect to socket Report Date:02-07-21 Time:16:20:19
UIMs
3-272 EAGLE Unsolicited Alarm and Information Messages Reference
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1475 - TOBR Multiple Comp: Translation found
This message indicates a translation has been found for more than one componenteven if its priority numbers are lower than the first component.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 5902.1475 CARD 1101 INFO TOBR Multiple Comp: Translation found SIO=03 OPC= 6-006-1 DPC= 7-007-7 SCCP MSG TYPE=09 CDPA: NI=0 RI=0 GTI=00 SSNI=0 PCI=1 PC= 3-132-5 SSN=--- CGPA: NI=0 RI=1 GTI=00 SSNI=1 PCI=1 PC= 0-141-7 SSN=146 LSN=ls661 GTTSETIDX=2 Report Date:16-12-07 Time:11:20:32
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1476 - TCAPMulComp: Dup Opcode MSU discarded
This message indicates the duplicate in a TCAP Message with the same Opcode inmore than one component has been discarded.
Example
12345678901234567890123456789012345678901234567890123456789012345678901234567890 5902.1476 CARD 1101 INFO TCAPMulComp: Dup Opcode MSU discarded SIO=03 OPC= 6-006-1 DPC= 7-007-7 SCCP MSG TYPE=09 CDPA: NI=0 RI=0 GTI=00 SSNI=0 PCI=1 PC= 3-132-5 SSN=--- CGPA: NI=0 RI=1 GTI=00 SSNI=1 PCI=1 PC= 0-141-7 SSN=146 LSN=ls661 GTTSETIDX=2 Report Date:16-12-07 Time:11:20:32
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action is necessary.
1491 - Terminal enabled
This message indicates that the specified telnet terminal has been successfully selectedby a user via telnet.
Example
UIMs
UAM and UIM Troubleshooting Procedures 3-273
RLGHNCXA21W 00-04-18 18:59:30 EST EAGLE 31.3.00105.1491 SYSTEM INFO Terminal enabled.TERMINAL 20
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1492 - Terminal failed
This message indicates that the specified telnet terminal has been disconnected.
Example
RLGHNCXA21W 00-04-18 18:59:30 EST EAGLE 31.3.00105.1492 SYSTEM INFO Terminal failed.TERMINAL 20
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
1493 - SSH Host Keys Regenerated
This message indicates that the OA&M IP Security Enhancements feature hassuccessfully generated new host pubic/private key pairs. This occurs during coldrestarts of an IPSM card. During initialization, this UIM displays the new key.
Note:
This UIM indicates a new public/private key is in effect. The old key is nowinvalid. The new key must be installed on SSH clients (on the FTRA) beforeany connections are permitted.
Example
RLGHNCXA21W 03-08-18 18:59:30 EST EAGLE 30.2.00105.1493 SYSTEM INFO SSH Host Keys RegeneratedDSA Server Host Key FTRA-formatted Fingerprint=xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx
Alarm Level: No alarm condition. The message is informational only.
Recovery
1. Record the DSA Server Host KeyFTRA-formatted fingerprint that is in the last lineof the UIM.
2. Save the fingerprint.
The fingerprint will be installed on the FTRA if the FTP Retrieve and Replacefeature is used.
UIMs
3-274 EAGLE Unsolicited Alarm and Information Messages Reference
Note:
Refer to the FTP-Based Table Retrieve Application (FTRA) User Guide for thefingerprint installation procedure.
1494 - SSH Host Keys Loaded
This message indicates that the OA&M IP Security Enhancements feature hassuccessfully preserved existing host pubic/private key pairs. This occurs duringreloads, init-card, and alw-card operations. During initialization, this UIM shows thestate of the existing host key.
Example
RLGHNCXA21W 03-08-18 18:59:30 EST EAGLE 30.2.00105.1494 SYSTEM INFO SSH Host Keys LoadedDSA Server Host Key FTRA-formatted Fingerprint=xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx
Alarm Level: No alarm condition. The message is informational only.
Recovery
No action necessary.
UIMs
UAM and UIM Troubleshooting Procedures 3-275
UIMs
3-276 Unsolicited Alarm and Information Messages Reference
AUAM Balancing Matrix
The tables in this appendix are in alphabetical order and list Critical, Major, Minor, andNormal alarms that appear for device conditions, and indicate the clearing alarm thatappears when each condition is resolved in the system. (Some device conditions arecategorized as Normal, and have an associated clearing alarm when the devicechanges to another Normal condition.)
Note: A generic clearing alarm, UAM 0500 “Alarm for this entitiy is beingcleared,” addresses scenarios where an alarm used to silently remove an activealarm did not make sense for the condition that was being cleared. This UAMis a generic alarm clearing output that applies to all setting alarms (Critical,Major, and Minor).
AIQ System AlarmsTable A-1 shows the AIQ System alarms and the clearing alarm that appears wheneach condition is resolved.
Table A-1 AIQ System Alarms
Critical Normal
UAM
Text UAM
Text
0592 AIQ Subsystem is not available 0595 AIQ Subsystem is available
0594 AIQ Subsystem normal, card(s)abnormal
0593 AIQ Subsystem is disabled 0596 AIQ Subsystem is removed
0594 AIQ Subsystem normal, card(s)abnormal
Minor Normal
0594 AIQ Subsystem normal, card(s)abnormal
0595 AIQ Subsystem is available
0596 AIQ Subsystem is removed
ATINP System AlarmsTable A-2 shows the critical and minor ATINP System alarms and the clearing alarmthat appears when each condition is resolved.
UAM Balancing Matrix A-1
Table A-2 ATINP System Alarms
Critical Normal
UAM
Text UAM
Text
0565 ATINPQ Subsystem is not available 0568
0569
ATINPQ Subsystem is available
ATINPQ Subsystem is removed
0566 ATINPQ Subsystem is disabled 0568
0569
ATINPQ Subsystem is available
ATINPQ Subsystem is removed
Major Normal
0429 ATINPQ Subsystem degraded,card(s) abnormal
0568
0569
ATINPQ Subsystem is available
ATINPQ Subsystem is removed
Minor Normal
0567 ATINPQ Subsystem normal,card(s)abnormal
0568
0569
ATINPQ Subsystem is available
ATINPQ Subsystem is removed
Card AlarmsTable A-3 shows the critical, major, and minor card alarms and the clearing alarm thatappears when each condition is resolved.
Table A-3 Card Alarms
Critical Normal
UAM
Text UAM
Text
0077 Card temperature is critical lvl:T2 0079 Card temperature again at nominallevels
0092 MDAL not responding 0093 MDAL alarm cleared
0127 ENUM card capacity exceeded 0126 ENUM Threshold Condition cleared
0442 RTDB database capacity is 95% full 0447 RTDB database capacity alarmcleared
Major Normal
UAM
Text UAM
Text
0001 Card has reset 0014 Card is present
0096 Card has been reloaded
0008 Active MASP has become isolated 0009 MASP became active
Card Alarms
A-2 EAGLE Unsolicited Alarm and Information Messages Reference
Table A-3 (Cont.) Card Alarms
0010 MASP became standby
0012 Invalid HW for IntegratedMeasurements
0519 Measurements subsystem available
0013 Card is isolated from the system 0014 Card is present
0096 Card has been reloaded
0031 HIPR2 detected a major CongestedSecond
0032 HIPR2 Congestion cleared
0053 Standby TDM failure 0054 Standby TDM failure cleared
0078 Card temperature exceeds nominallvl:T1
0079 Card temperature again at nominallevels
0088 Clocks A and B TSCs are out of sync 0089 Clocks A and B TSCs areresynchronized
0125 ENUM Threshold -Level 2 exceeded 0126 ENUM Threshold Condition cleared
0132 Loading failed: table not found 0096 Card has been reloaded
0133 Loading failed: data read error
0134 Loading failed: bad checksumreturned
0135 Loading failed: GPL load timeout
0136 Loading failed: data load timeout
0137 Loading failed: invalid GPL
0138 Loading failed: GPL format error
0139 Loading failed: disk read prep error
0140 Loading failed: disk read responseerror
0141 Loading failed: disk read failed
0300 TVG Grant Failure 0301 TVG Grant Recovery
0306 SNM Overload Onset 0307 SNM Overload Abated
0043 Incorrect feature configuration 0423 Card reload attempted
0047 Card type not valid for application
0099 Incompatible HW for provisionedslot
Card Alarms
UAM Balancing Matrix A-3
Table A-3 (Cont.) Card Alarms
0276 Insufficient HW for IP7 provisioning
0297 Incorrect port configuration
0422 Insufficient extended memory
0441 Incorrect MDB – CPU
0446 RTDB database capacity is 80% full 0447 RTDB database capacity alarmcleared
0449 RTDB resynchronization in progress 0445 RTDB database has been corrected
0500 Alarm for this entitiy is being cleared
0443 RTDB database is corrupted 0445 RTDB database has been corrected
0451 RTDB reload is required
0514 Standby MASP is inhibited 0515 Standby MASP is allowed
0901 CardDB load timeout, check GLScard
0902 CardDB is stable
0903 IPLink A is down 0904 IPLink A is up
0905 IPLink B is down 0906 IPLink B is up
0908 HW cannot support purchased TPSrate
0907 HW limiting TPS rate alarm cleared
0051 TSC Sync is in simplex mode 0052 TSC sync feature is available
0466 STC Network Unavailable 0467 STC Network Available
0088 Clocks A and B TSCs are out of sync 0089 Clocks A and B TSCs areresynchronized
0390 Illegal Address Error 0388 Illegal Address Error Cleared
0391 Card not responding Error 0389 Card responding normally
0573 BERT Test Failed 0574 BERT Test Passed
0575 Card type not HIPR2 0500 Alarm for this entity is being cleared
0548 GTT HexTree DB corrupted. TPSderated
0550 GTT HexTree DB alarm cleared
0549 GTT HexTree DB incoherent. TPSderated
Minor Normal
Card Alarms
A-4 EAGLE Unsolicited Alarm and Information Messages Reference
Table A-3 (Cont.) Card Alarms
UAM
Text UAM
Text
0022 Clock B for card failed, Clock Anormal
0025 Clock B for card normal
0023 Clocks A and B for card failed 0026 Clocks A and B for card normal
0030 HIPR2 detected a minor CongestedSecond
0032 HIPR2 Congestion cleared
0034 Card database is inconsistent 0033 Card database has been corrected
0035 Card database is corrupted
0037 Card backup database is inconsistent 0036 Card backup database has beencorrected
0038 Card backup database is corrupted
0044 Real time clock battery low 0045 Real time clock battery restored
0055 Persistent device state tbl corrupt 0057 Persistent device state tbl corrected
0056 Persistent device state tbl diff ver
0102 Motherboard BIP invalid 0103 Motherboard BIP valid
0124 ENUM Threshold -Level1 exceeded 0126 ENUM Threshold Condition cleared
0145 HS Clock A for card failed, B normal 0148 High Speed Clock A for card normal
0146 HS Clock B for card failed, A normal 0149 High Speed Clock B for card normal
0147 High Speed Clocks A and B for cardfailed
0159 High Speed Clocks A and B for cardnormal
0298 Card not using config. SCTP csummethod
0299 Config. SCTP csum method alarmcleared
0304 REPT-NMTSK-DSCD: SNMDiscard Onset
0305 RECVY-NMTSK-DSCD: SNMDiscard Abated
0444 RTDB database is inconsistent 0445 RTDB database has been corrected
0448 RTDB database incoherent
0466 STC Network Unavailable 0467 STC Network Available
0480 Timestamp Invalid 0481 Timestamp Valid
0498 Sanity monitoring is disabled 0499 Sanity monitoring is enabled
0130 Card successfully loaded with data
0400 Alarm cleared by deleting card
Card Alarms
UAM Balancing Matrix A-5
Table A-3 (Cont.) Card Alarms
0294 REPT-ALMINH: alarm outputPERM inhibit
0295 REPT-ALMINH: alarm outputenabled
0296 REPT-ALMINH: alarm outputTEMP inhibit
0570 Incompatible flash image for sys rel 0423 Card reload attempted
0579 FC Network Unavailable 0580 FC Network Available
0581 Loss of heartbeat 0582 Heartbeat Available
0590 Fast Copy Application De-activated 0591 Fast Copy Application Activated
CDT (Customer Defined Trouble) AlarmsTable A-4 shows the critical, major, minor, and normal card alarms and the clearingalarm that appears when each condition is resolved.
Table A-4 CDT (Customer Defined Trouble) Alarms
Critical Normal
UAM
Text UAM
Text
0058 Critical customer trouble detected 0062 Customer trouble cleared
Major Normal
0059 Major customer trouble detected 0062 Customer trouble cleared
Minor Normal
0060 Minor customer trouble detected 0062 Customer trouble cleared
Normal Normal
0061 Customer trouble detected 0062 Customer trouble cleared
Clock (Holdover Clock) AlarmsTable A-5 shows the critical, major, and minor Holdover Clock alarms and the clearingalarm that appears when each condition is resolved.
Table A-5 Clock (Holdover) Alarms
Critical Normal
CDT (Customer Defined Trouble) Alarms
A-6 EAGLE Unsolicited Alarm and Information Messages Reference
Table A-5 (Cont.) Clock (Holdover) Alarms
UAM
Text UAM
Text
0063 Critical holdover clock trbl detected 0066 Holdover clock trouble cleared
Major Normal
0064 Major holdover clock troubledetected
0066 Holdover clock trouble cleared
Minor Normal
UAM
Text UAM
Text
0065 Minor holdover clock troubledetected
0066 Holdover clock trouble cleared
Clock System AlarmsTable A-6 shows the critical, major, and minor clock alarms and the clearing alarm thatappears when each condition is resolved.
Table A-6 Clock System Alarms
Critical Normal
UAM
Text UAM
Text
0128 All clocks have failed 0113 Clock alarm(s) cleared
Major Normal
UAM
Text UAM
Text
0162 1116-P, 1116-S clocks failed 0113 Clock alarms cleared
0164 1114-S, 1116-S clocks failed
0166 1114-S, 1116-P, 1116-S clocks failed
0169 1114-P, 1116-P clocks failed
0170 1114-P, 1116-P, 1116-S clocks failed
0171 1114-P, 1114-S clocks failed
0172 1114-P, 1114-S, 1116-S clocks failed
0173 1114-P, 1114-S, 1116-P clocks failed
Minor Normal
Clock System Alarms
UAM Balancing Matrix A-7
Table A-6 (Cont.) Clock System Alarms
UAM
Text UAM
Text
0160 1116-S clock failed 0113 Clock alarms cleared
0161 1116-P clock failed
0163 1114-S clock failed
0165 1114-S, 1116-P clocks failed
0167 1114-P clock failed
0168 1114-P, 1116-S clocks failed
DCM AlarmsTable A-7 shows the major DCM alarm and the clearing alarm that appears when thecondition is resolved.
Table A-7 DCM Alarms
Major Normal
UAM
Text UAM
Text
0084 IP Connection Unavailable 0085 IP Connection Available
DLK AlarmsTable A-8 shows the major and minor DLK alarm and the clearing alarm that appearswhen the condition is resolved.
Table A-8 DLK Alarms
Major Normal
UAM
Text UAM
Text
0537 Ethernet error threshold exceeded 0538 Ethernet error threshold cleared
0539 Ethernet Interface Down 0540 Ethernet Interface Up
0588 FC Port De-activated 0589 FC Port Activated
Minor Normal
UAM
Text UAM
Text
0155 STPLAN connection unavailable 0156 STPLAN connection available
DCM Alarms
A-8 EAGLE Unsolicited Alarm and Information Messages Reference
Table A-8 (Cont.) DLK Alarms
0536 IP Connection Excess Retranmists 0084 IP Connection Available
0085 IP Connection Available
DPC AlarmsTable A-9 shows the critical, minor, and normal DPC alarms and the clearing alarmthat appears when each condition is resolved.
Table A-9 DPC Alarms
Critical Other Alarm ConditionsWhich Clear Given Alarm
Normal
UAM
Text UAM
Text UAM
Text
0313 DPC is prohibited 0312 DPC is restricted 0311 DPC is allowed
0319 REPT-MTPLP-DET:Circ rte det(cong)
0402 Alarm cleared bydeleting route
0334 DPC subsystem isAbnormal
Minor Other Alarm ConditionsWhich Clear Given Alarm
Normal
UAM
Text UAM
Text UAM
Text
0312 DPC is restricted 0313 DPC is prohibited 0311 DPC is allowed
0319 REPT-MTPLP-DET:Circ rte det(cong)
0402 Alarm cleared bydeleting route
0334 DPC subsystem isAbnormal
Normal Other Alarm ConditionsWhich Clear Given Alarm
Normal
0315 Route is restricted 0316 Route is prohibited 0314 Route is allowed
0319 REPT-MTPLP-DET:Circ rte det(cong)
0402 Alarm cleared bydeleting route
0316 Route is prohibited 0315 Route is restricted 0314 Route is allowed
0319 REPT-MTPLP-DET:Circ rte det(cong)
0402 Alarm cleared bydeleting route
DPC Alarms
UAM Balancing Matrix A-9
DPC System AlarmsTable A-10 shows the critical and normal DPC System alarms and the clearing alarmthat appears when each condition is resolved.
Table A-10 DPC System Alarms
Critical Other Alarm ConditionsWhich Clear Given Alarm
Normal
UAM
Text UAM
Text UAM
Text
0325 DPC subsystem isblocked
0312 DPC is restricted 0324 DPC subsystem isallowed
0319 REPT-MTPLP-DET:Circ rte det(cong)
0327 DPC subsystem hasbeen deleted
0326 DPC subsystem isprohibited
0333 DPC subsystem isNormal
0332 DPC subsystem isprohibited andblocked
0334 DPC subsystem isAbnormal
0326 DPC subsystem isprohibited
0312 DPC is restricted 0324 DPC subsystem isallowed
0319 REPT-MTPLP-DET:Circ rte det(cong)
0327 DPC subsystem hasbeen deleted
0325 DPC subsystem isblocked
0333 DPC subsystem isNormal
0332 DPC subsystem isprohibited andblocked
0334 DPC subsystem isAbnormal
0332 DPC subsystem isprohibited andblocked
0312 DPC is restricted 0324 DPC subsystem isallowed
0319 REPT-MTPLP-DET:Circ rte det(cong)
0327 DPC subsystem hasbeen deleted
0325 DPC subsystem isblocked
0333 DPC subsystem isNormal
0326 DPC subsystem isprohibited
DPC System Alarms
A-10 EAGLE Unsolicited Alarm and Information Messages Reference
Table A-10 (Cont.) DPC System Alarms
0334 DPC subsystem isAbnormal
0334 DPC subsystem isAbnormal
0319 REPT-MTPLP-DET:Circ rte det(cong)
0324 DPC subsystem isallowed
0327 DPC subsystem hasbeen deleted
0333 DPC subsystem isNormal
0319 REPT-MTPLP-DET:Circ rte det(cong)
0340 RCVRY-MTPLP-RST: Circ rte statuscleared
0320 REPT-MTPLP-SUST:Sustained circ rt(cong)
0340 RCVRY-MTPLP-RST: Circ rte statuscleared
0337 DPC-SS1 statuschanged
1 When DPC subsystem transitions between prohibited and block to either blocked or prohibited only, thisUAM is raised.
DSM AlarmsTable A-11 shows the major DSM alarm and the clearing alarm that appears when thecondition is resolved.
Table A-11 DSM Alarms
Major Normal
UAM
Text UAM
Text
0084 IP Connection Unavailable 0085 IP Connection Available
E1 Port AlarmsTable A-12 shows the major E1 alarms and the clearing alarm that appears when eachcondition is resolved.
Table A-12 E1 Port Alarms
Major Normal
UAM
Text UAM
Text
DSM Alarms
UAM Balancing Matrix A-11
Table A-12 (Cont.) E1 Port Alarms
0381 REPT-E1F:FAC-E1LOS failure 0386 RCVRY-E1F:FAC-E1 available
0382 REPT-E1F:FAC-E1LOF failure
0383 REPT-E1F:FAC-E1AIS detected
0384 REPT-E1F:FAC-E1 Far End failure
0385 REPT-E1F:FAC-E1 10E-3 BER failed
0387 REPT-E1F:FAC-E1 unavailable
EIR AlarmsTable A-13 shows the critical and minor EIR alarms and the clearing alarm thatappears when each condition is resolved.
Table A-13 EIR Alarms
Critical Normal
UAM
Text UAM
Text
0455 EIR System is not available 0458 EIR Subsystem is available
0459 EIR Subsystem is removed
0456 EIR Subsystem is disabled 0458 EIR Subsystem is available
0459 EIR Subsystem is removed
Major Normal
0460 EIR Subsystem degraded, card(s)abnormal
0458 EIR Subsystem is available
0459 EIR Subsystem is removed
Minor Normal
0457 EIR Subsystem normal,card(s)abnormal
0458 EIR Subsystem is available
0459 EIR Subsystem is removed
ENET System AlarmsTable A-14 shows the ENET System alarms and the clearing alarm that appears wheneach condition is resolved.
Table A-14 ENET System Alarms
Major Normal
EIR Alarms
A-12 EAGLE Unsolicited Alarm and Information Messages Reference
Table A-14 (Cont.) ENET System Alarms
UAM
Text UAM
Text
0537 Ethernet error threshold exceeded 0538 Ethernet error threshold cleared
0539 Ethernet Interface Down 0540 Ethernet Interface Up
Minor Normal
0536 IP Connection Excess Retranmists 0085 IP Connection Available
ENUM System AlarmsTable A-15 shows the ENUM System alarms and the clearing alarm that appears wheneach condition is resolved.
Table A-15 ENUM System Alarms
Critical Normal
UAM
Text UAM
Text
0120 ENUM SYSTEM is not available 0121 ENUM SYSTEM is available
0123 ENUM SYSTEM is removed
Major Normal
0122 ENUM SYSTEM normal, card(s)abnormal
0121 ENUM SYSTEM is available
0123 ENUM SYSTEM is removed
EROUTE AlarmsTable A-16 shows the critical, major, and minor EROUTE alarms and the clearingalarm that appears when each condition is resolved.
Table A-16 EROUTE Alarms
Critical Normal
UAM
Text UAM
Text
0468 All STC Networks Unavailable 0470 EROUTE is Removed
0469 All STC Cards Unavailable 0471 EROUTE System is Available
Major Normal
0473 EROUTE System Capacity Exceeded 0470 EROUTE is Removed
ENUM System Alarms
UAM Balancing Matrix A-13
Table A-16 (Cont.) EROUTE Alarms
0482 Card(s) have been denied EROUTEservice
0471 EROUTE System is Available
Minor Normal
0472 EROUTE System ThresholdExceeded
0470 EROUTE is Removed
0471 EROUTE System is Available
0474 EROUTE capacity normal, card(s)abnormal
0470 EROUTE is Removed
0471 EROUTE System is Available
0475 NTP Time Unavailable 0476 NTP Time Available
Ethernet Error Threshold AlarmsTable A-17 shows the major ethernet error threshold alarms and the clearing alarmthat appears when each condition is resolved.
Table A-17 Ethernet Error Threshold Alarms
Major Normal
0537 Ethernet error threshold exceeded 538 Ethernet error threshold cleared
0539 Ethernet Interface Down 0540 Ethernet Interface Up
Fast Copy System AlarmsTable A-18 shows the major and minor Fast Copy System alarms and the clearingalarm that appears when the condition is resolved.
Table A-18 Fast Copy System Alarms
Major Normal
UAM
Text UAM
Text
0576 All FC Network Unavailable 0577 All FC cards removed
0578 FC System is Available
Minor Normal
597 FC System is Deactivated 0578 FC System is Available
Frame AlarmsTable A-19 shows the major Frame alarms and the clearing alarms that appear whenthe condition is resolved.
Ethernet Error Threshold Alarms
A-14 EAGLE Unsolicited Alarm and Information Messages Reference
Table A-19 Frame Alarms
Critical Normal
UAM
Text UAM
Text
0520 Frame power usage reached LVL3 0523 Frame power usage normal
Major Normal
UAM
Text UAM
Text
0521 Frame power usage reached LVL2 0523 Frame power usage normal
Minor Normal
UAM
Text UAM
Text
0522 Frame power usage reached LVL1 0523 Frame power usage normal
Fuse AlarmsTable A-20 shows the major fuse alarm and the clearing alarm that appears when thecondition is resolved.
Table A-20 Fuse Alarms
Major Normal
UAM
Text UAM
Text
0082 Alarm in fuse panel 0083 Fuse panel alarm has cleared
GLS AlarmsTable A-21 shows the critical and major GLS alarms and the clearing alarm thatappears when each condition is resolved.
Table A-21 GLS Alarms
Critical Normal
UAM
Text UAM
Text
0292 GLS is not available 0290 GLS is available
0293 GLS have been removed from thesystem
Fuse Alarms
UAM Balancing Matrix A-15
Table A-21 (Cont.) GLS Alarms
Major Normal
0291 GLS is at minimum service limit 0290 GLS is available
0293 GLS have been removed from thesystem
0450 Invalid HW for Integrated GLS 0290 GLS is available
GPL AlarmsTable A-22 shows the minor GPL alarms and the clearing alarm that appears wheneach condition is resolved.
Table A-22 GPL Alarms
Critical Normal
UAM
Text UAM
Text
0002 Card is not running approved GPL 0003 Alarm cleared for GPL
0004 Card is running non-activated GPL 0005 Alarm cleared running non-activatedGPL
0040 GPL is corrupted 0039 GPL has been corrected
Group Broadcast Alarmsshows the critical and minor Group Broadcast alarms and the clearing alarm thatappears when each condition is resolved.
Table A-23 Group Broadcast Alarms
Critical Normal
0015 Group Broadcast Registration Failed 0017 Group Broadcast RegistrationSucceeded
Minor Normal
0016 Single IMT Bus GB Registration 0017 Group Broadcast RegistrationSucceeded
GTT AlarmsTable A-24 shows the major GTT alarm and the clearing alarm that appears when thecondition is resolved.
GPL Alarms
A-16 EAGLE Unsolicited Alarm and Information Messages Reference
Table A-24 GTT System Alarms
Critical Normal
UAM
Text UAM
Text
0630 Throttle Threshold - exceeded 0631 Throttle Threshold - cleared
HS Clock System AlarmsTable A-25 shows the critical, major, and minor HS Clock System alarms and theclearing alarm that appears when each condition is resolved.
Table A-25 HS Clock System Alarms
Critical Normal
UAM
Text UAM
Text
0197 All high speed clocks have failed 0198 High Speed clock alarm(s) cleared
Major Normal
UAM
Text UAM
Text
0185 1116-PHS, 1116-SHS clocks failed 0198 High Speed clock alarm(s) cleared
0187 1114-SHS, 1116-SHS clocks failed
0189 1114-SHS, 1116-PHS,1116-SHS clksfailed
0192 1114-PHS, 1116-PHS clocks failed
0193 1114-PHS, 1116-PHS,1116-SHS clksfailed
0194 1114-PHS, 1114-SHS clocks failed
0195 1114-PHS, 1114-SHS, 1116-SHS clksfailed
0196 1114-PHS, 1114-SHS, 1116-PHS clksfailed
403 1114 E1/T1 clock requires TDM-GTI 409 Clock configuration corrected
404 1116 E1/T1 clock requires TDM-GTI
405 1114, 116 E1/T1 clock requires TDM-GTI
406 1114 Clock selection mismatch
HS Clock System Alarms
UAM Balancing Matrix A-17
Table A-25 (Cont.) HS Clock System Alarms
407 1116 Clock selection mismatch
408 1114, 1116 Clock selection mismatch
Minor Normal
UAM
Text UAM
Text
0183 1116-SHS clock failed 0198 High speed clock alarm(s) cleared
0184 1116-PHS clock failed
0186 1114-SHS clock failed
0188 1114-SHS, 1116-PHS clocks failed
0190 1114-PHS clock failed
0191 1114-PHS, 1116-SHS clocks failed
IMT Bus AlarmsTable A-26 shows the major, minor, and normal IMT Bus alarms and the clearingalarm that appears when each condition is resolved.
Table A-26 IMT Bus Alarms
Major Normal
UAM
Text UAM
Text
0108 Major IMT failure detected 0106 IMT bus alarm cleared
Minor Normal
0107 Minor IMT failure detected 0106 IMT bus alarm cleared
Normal Normal
0098 IMT inhibited 0097 IMT allowed
IMT System AlarmsTable A-27 shows the critical, major, and minor IMT System alarms and the clearingalarm that appears when each condition is resolved.
Table A-27 IMT System Alarms
Critical Normal
IMT Bus Alarms
A-18 EAGLE Unsolicited Alarm and Information Messages Reference
Table A-27 (Cont.) IMT System Alarms
UAM
Text UAM
Text
0112 Major failures detected on both IMTs 0109 All IMT system level alarms cleared
Major Normal
0028 IMT Bus util rate exceeds majorthresh
0029 IMT Bus utilization threshold cleared
0111 Failure on both IMT A and IMT B 0109 All IMT system level alarms cleared
0563 IMT Bit rate mismatch detected 0564 IMT Bit rate mismatch cleared
Minor Normal
0027 IMT Bus util rate exceeds minorthresh
0029 IMT Bus utilization threshold cleared
0110 Failure detected on one IMT bus 0109 All IMT system level alarms cleared
INP System AlarmsTable A-28 shows the critical and minor NP System alarms and the clearing alarm thatappears when each condition is resolved.
Table A-28 INP System Alarms
Critical Normal
UAM
Text UAM
Text
0395 INP Subsystem is not available 0394 INP Subsystem is available
0396 INP Subsystem is disabled 0397 INP Subsystem is removed
Major Normal
0428 INP Subsystem degraded, card(s)abnormal
0394 INP Subsystem is available
Minor Normal
0398 INP Subsystem normal, card(s)abnormal
0394 INP Subsystem is available
0397 INP Subsystem is removed
IP7CONN AlarmsTable A-29 shows the major and minor IP Connection alarms and the clearing alarmthat appears when each condition is resolved.
INP System Alarms
UAM Balancing Matrix A-19
Table A-29 IP Connection Alarms
Major Normal
UAM
Text UAM
Text
0084 IP Connection Unavailable 0085 IP Connection Available
0087 IP Connection manually removed
Minor Normal
0086 IP Connection Congested 0085 IP Connection Available
0087 IP Connection manually removed
0535 IP Connection Restricted 0085 IP Connection Available
0536 IP Connection Excess Retransmits 0085 IP Connection Available
IP7 AlarmsTable A-30 shows the major and minor IP Connection alarms and the clearing alarmthat appears when each condition is resolved.
Table A-30 IP Connection Alarms
Major Normal
UAM
Text UAM
Text
0277 AS Unavailable 0278 AS Available
Minor Normal
0279 AS Restricted 0280 AS Unrestricted
Linkset AlarmsTable A-31 shows the Linkset alarm and the clearing alarms that appears when thecondition is resolved.
Table A-31 Linkset Alarms
Major Normal
UAM
Text UAM
Text
0115 Linkset IP TPS threshold exceeded 0118 Linkset IP TPS threshold normal
0318 REPT-LKSTO: link set prohibited 0317 RCVRY-LKSTO: link set allowed
IP7 Alarms
A-20 EAGLE Unsolicited Alarm and Information Messages Reference
Table A-31 (Cont.) Linkset Alarms
0399 RRCVRY-LKSTO:Alarm clr’d bydeleting SLK
0560 REPT-LKSTO: link set restricted 0317 REPT-LKSTO: link set restricted
LNP System AlarmsTable A-32 shows the critical and major LNP System alarms and the clearing alarmthat appears when each condition is resolved.
Table A-32 LNP System Alarms
Critical Normal
UAM
Text UAM
Text
0424 LNP Subsystem is not available 0426 LNP Subsystem is available
0435 LNP Subsystem is disabled 0434 LNP Subsystem is removed
0287 RTDB Table Level 2 FAK Capexceeded
0289 RTDB Table FAK Capacity Normal
Major Normal
0283 LNP Ported NPAs approaching Feat.Capacity
0284 LNP Ported NPAs Capacity Normal
0285 LNP Ported LRNs approaching Feat.Capacity
0286 LNP Ported LRNs Capacity Normal
0288 RTDB Table Level 1 FAK Capexceeded
0289 RTDB Table FAK Capacity Normal
0427 LNP Subsystem degraded, card(s)abnormal
0426 LNP Subsystem is available
0436 LNPACG node overload 0426 LNP Subsystem is available
Minor Normal
0425 LNP Subsystem normal, card(s)abnormal
0426 LNP Subsystem is available
LSMS Connection AlarmsTable A-33 shows the critical and major LSMS Connection alarms and the clearingalarm that appears when each condition is resolved.
LNP System Alarms
UAM Balancing Matrix A-21
Table A-33 LSMS Connection Alarms
Critical Normal
UAM
Text UAM
Text
0041 LNPDB Maintenance required. 0042 LSMS bulk load complete.
Major Normal
0358 LSMS connection unavailable 0359 LSMS connection available
LSMS System AlarmsTable A-34 shows the critical and major LSMS System alarms and the clearing alarmthat appears when each condition is resolved.
Table A-34 LSMS System Alarms
Critical Normal
UAM
Text UAM
Text
0356 LSMS unavailable 0355 LSMS is available
0357 All OAP terminals are removed
0350 OAP terminals inhibited 0355 LSMS is available
0357 All OAP terminals are removed
Major Normal
0341 OAP unavailable 0353 OAP is available
0354 One OAP terminal unavailable 0357 All OAP terminals are removed
0362 LSMS is at min service limit 0355 LSMS is available
0357 All OAP terminals are removed
MCPM AlarmsTable A-35 shows the major MCPM alarm and the clearing alarm that appears whenthe condition is resolved.
Table A-35 MCPM Alarms
Major Normal
UAM
Text UAM
Text
LSMS System Alarms
A-22 EAGLE Unsolicited Alarm and Information Messages Reference
Table A-35 (Cont.) MCPM Alarms
0084 IP Connection Unavailable 0085 IP Connection Available
MEAS System AlarmsTable A-36 shows the critical, major, and minor MEAS System alarms and the clearingalarm that appears when each condition is resolved.
Table A-36 MEAS System Alarms
Critical Normal
UAM
Text UAM
Text
0518 Measurements subsystemunavailable
0519 Measurements subsystem available
Major Normal
0517 Degraded Mode - multiple cardsfailed
0519 Measurements subsystem available
Minor Normal
0516 Degraded Mode - 1 card failed 0519 Measurements subsystem available
MPS (ELAP/EPAP) AlarmsTable A-37 shows the critical, major, and minor MPS (ELAP/EPAP) alarms and theclearing alarm that appears when each condition is resolved.
Table A-37 MPS (ELAP/EPAP) Alarms
Critical Normal
UAM
Text UAM
Text
0370 Critical Platform Failure(s) 0250 MPS available
0371 Critical Application Failure(s)
0261 MPS unavailable
Major Normal
0372 Major Platform Failure(s) 0250 MPS available
0373 Major Application Failure(s)
Minor Normal
0374 Minor Platform Failure(s) 0250 MPS available
MEAS System Alarms
UAM Balancing Matrix A-23
Table A-37 (Cont.) MPS (ELAP/EPAP) Alarms
0375 Minor Application Failure(s)
Note:
Critical Platform/Application alarms cause the MPS to go OOS-MT andMajor/Minor Platform/Applications alarms cause the MPS to go IS-ANR.
MPS Alarm SupportThe MPS running software Release 2.0 (ELAP) or higher, Release 27.0 will supportMPS alarms (370-375), as well as UAMs 442-451 against a card.
Table A-38 MPS Alarm Support
Release 27.0 and higher
UAM # Format
0442
0446
0447
CARD
0443-0445
0448-0451
CARD
0370-0375 MPS1
0250 MPS2
RTX System AlarmsTable A-39 shows the major RTX system alarms and the clearing alarm that appearswhen the condition is resolved.
Table A-39 RTX System Alarms
Critical Other alarm conditionswhich clear givenalarm
Normal
UAM
Text UAM
Text
0534 RTX is prohibited 0533
RTX is restricted 0532 RTX is allowed
0319
REPT-MTPLP-DET:Circ rte det(cong)
0402 Alarm cleared bydeleting route
MPS Alarm Support
A-24 EAGLE Unsolicited Alarm and Information Messages Reference
Table A-39 (Cont.) RTX System Alarms
Minor Other alarm conditionswhich clear givenalarm
Normal
UAM
Text UAM
Text
0533 RTX is restricted 0534
RTX is prohibited 0532 RTX is allowed
0319
REPT-MTPLP-DET:Circ rte det(cong)
0402 Alarm cleared bydeleting route
SCCP Service AlarmsTable A-40 shows the critical, major, and minor SCCP service alarms and the clearingalarm that appears when each condition is resolved.
Table A-40 SCCP Service Alarms
Critical Normal
UAM
Text UAM
Text
0528 Service is not available 0526 Service is available
0530 Service is removed
0529 Service is disabled 0526 Service is available
0530 Service is removed
Major Normal
0547 Service degraded 0526 Service is available
0530 Service is removed
Minor Normal
0527 Service abnormal 0526 Service is available
0530 Service is removed
SCCP System AlarmsTable A-41 shows the critical, major, and minor SCCP system alarms and the clearingalarm that appears when each condition is resolved.
Table A-41 SCCP System Alarms
Critical Normal
SCCP Service Alarms
UAM Balancing Matrix A-25
Table A-41 (Cont.) SCCP System Alarms
UAM
Text UAM
Text
0331 SCCP is not available 0328 SCCP is available
0335 SCCP is removed
0437 System SCCP TPS CapacityExceeded
0329 System SCCP TPS normal
0453 Exceeded Service Error Threshold Lvl2
0454 Service Error Threshold AlarmCleared
Major Normal
0262 GTT Duplicate Actn processingstopped
0263 GTT Duplicate Actn processingresumed
0336 LIM(s) have been denied SCCPservice
0328 SCCP is available
0335 SCCP is removed
0452 Exceeded Service Error Threshold Lvl1
0454 Service Error Threshold AlarmCleared
Minor Normal
0330 System SCCP TPS Thresholdexceeded
0329 System SCCP TPS normal
0335 SCCP is removed
0632 Alarm Threshold - exceeded 0631 Throttle Threshold - cleared
0633 Alarm Threshold - cleared
SCTP Retransmit AlarmsTable A-42 shows the critical, major, and minor SCTP retransmit alarms and theclearing alarm that appears when each condition is resolved.
Table A-42 SCTP Retransmit Alarms
Minorl Normal
UAM
Text UAM
Text
0536 IP Connection Excess Retransmits 0085 IP Connection Available
SEAS OAP AlarmsTable A-43 shows the major and minor SEAS OAP alarms and the clearing alarm thatappears when each condition is resolved.
SCTP Retransmit Alarms
A-26 EAGLE Unsolicited Alarm and Information Messages Reference
Table A-43 SEAS Major OAP Alarms
Major Normal
UAM
Text UAM
Text
0341 OAP unavailable 0353 OAP is available
0342 SEASUAL unavailable
0354 One OAP terminal unavailable
0360 EMS Agent unavailable 0361 EMS Agent available
Table A-44 SEAS Minor OAP Alarms
Minor Normal
UAM
Text UAM
Text
0364 Configuration data checksummismatch
0365 Configuration data checksum alarmcleared
0363 OAP filesystem full 0361 EMS Agent available
SEAS System AlarmsTable A-45 shows the critical and major SEAS System alarms and the clearing alarmthat appears when each condition is resolved.
Table A-45 SEAS System Alarms
Critical Normal
UAM
Text UAM
Text
0349 SEAS unavailable 0351 SEAS is available
0350 OAP terminals inhibited 0352 SEAS is removed
Major Normal
0348 SEAS is at min service limit 0351 SEAS is available
0352 SEAS is removed
SEAS X25 AlarmsTable A-46 shows the major and minor SEAS X25 alarms and the clearing alarm thatappears when each condition is resolved.
SEAS System Alarms
UAM Balancing Matrix A-27
Table A-46 SEAS X25 Alarms
Major Normal
UAM
Text UAM
Text
0343 SEAS X.25 Link unavailable 0347 SEAS X.25 Link is available
0345 All SEAS UAL sessions unavailable
Minor Normal
0344 SEASPVC unavailable 0347 SEAS X.25 Link is available
0346 SEASUAL session unavailable
Security Log AlarmTable A-47 shows the minor and normal Security Log alarms and the clearing alarmthat appears when each condition is resolved.
Table A-47 Security Log Alarms
Minor Normal
UAM
Text UAM
Text
0174 %full threshold reached-uploadrequired
0177 Security log exception cleared
0175 LOGGUFROVFL-SECUL–G -upload required
0176 Stby security log – upload required
Normal Normal
0178 Security log failed 0177 Security log exception cleared
Security System AlarmsTable A-48 shows the major Security System alarm and the clearing alarm that appearswhen the condition is resolved.
Table A-48 Security System Alarms
Major Normal
UAM
Text UAM
Text
Security Log Alarm
A-28 EAGLE Unsolicited Alarm and Information Messages Reference
Table A-48 (Cont.) Security System Alarms
0392 OA&M IP Security feature status isOFF
0393 OA&M IP Security feature status isON
0199 OA&M IP Security feature disabled
Minor Normal
0157 OA&M Security Feature Riskdetected
0158 OA&M Security Feature Risk cleared
SFLOG System AlarmsTable A-49 shows the critical SFLOG system alarm and the clearing alarm thatappears when the condition is resolved.
Table A-49 SFLOG System Alarms
Critical Normal
UAM
Text UAM
Text
0627 SFLOG SYSTEM is not available 0628 SFLOG SYSTEM is available
0629 SFLOG SYSTEM is removed
SLK AlarmsTable A-50 shows the major, minor, and normal SLK alarms and the clearing alarmthat appears when each condition is resolved.
Table A-50 SLK Alarms
Major Normal
UAM
Text UAM
Text
0201 REPT-LKF: remote NE loopback 0223 REPT-LKF: remote NE loopbackcleared
0401 Alarm cleared by deleting SLK
0202 REPT-LKF: HWP -too manyinterrupts
0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0203 REPT-LKF: lost data 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0204 REPT-LKF: XER-ERM thresholdexceeded
0200 RCVRY-LKF: link available
SFLOG System Alarms
UAM Balancing Matrix A-29
Table A-50 (Cont.) SLK Alarms
0401 Alarm cleared by deleting SLK
0205 REPT-LKF: APF - lvl-2 T1 expd(ready)
0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0206 REPT-LKF: APF -lvl-2 T1 expd(notready)
0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0207 REPT-LKF: APF - lvl-2 T3 expired 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0208 REPT-LKF: APF - lvl-2 T2 expired 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0209 REPT-LKF: APF - failed provingperiod
0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0210 REPT-LKF: OSA - received SIO 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0211 REPT-LKF: OSA - received SIN 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0212 REPT-LKF: OSA - received SIE 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0213 REPT-LKF: OSA - received SIOS 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0214 REPT-LKF: ABN - rcvd 2 of 3 invalidBSN
0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0215 REPT-LKF: ABN - rcvd 2 of 3 invalidFIB
0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0216 REPT-LKF: remote congestiontimeout
0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0217 REPT-LKF: XDA - excessacknowledge delay
0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0218 REPT-LKF: COO - rcvd changeoverorder
0200 RCVRY-LKF: link available
SLK Alarms
A-30 EAGLE Unsolicited Alarm and Information Messages Reference
Table A-50 (Cont.) SLK Alarms
0401 Alarm cleared by deleting SLK
0219 REPT-LKF: false congestion restart 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0222 REPT-LKF: remote FE loopback 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0224 REPT-LKF: link test failed 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0230 REPT-LKF: local blocked - thermal 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0232 REPT-LKF: remote blocked 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0233 REPT-LINK-MANUAV: localblocked
0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0234 REPT-LKF: RMI remote inhibited 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0235 REPT-LINK-MGTINH: localinhibited
0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0236 REPT-LKF: not aligned 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0237 REPT-LKF: LM Timer NO-CREDITexpired
0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0238 REPT-LKF: XDA-Timer NO-RESPONSE expired
0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0239 REPT-LKF: MBL - local processoroutage
0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0240 REPT-LKF: rcvd remote processoroutage
0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0241 REPT-LKF: rcvd remote out ofservice
0200 RCVRY-LKF: link available
SLK Alarms
UAM Balancing Matrix A-31
Table A-50 (Cont.) SLK Alarms
0401 Alarm cleared by deleting SLK
0242 REPT-LKF: rcvd remote protocolerror
0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0243 REPT-LKF: rcvd remote mgmntinitiated
0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0244 REPT-LKF: FAC - DS1/E1 LOSfailure
0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0245 REPT-LKF: FAC - DS1/E1 LOFfailure
0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0246 REPT-LKF: FAC - DS1/E1 LCDfailure
0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0247 REPT-LKF: XER - ISERM thresholdexceeded
0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
Minor Normal
UAM
Text UAM
Text
0116 Link expected IP TPS thresholdexceeded
0119 LinkIPTPS threshold normal
0477 Congestion: Copy Function De-activated
0479 Link not monitored
0531 Insufficient HW Copy FunctionInhibited
0478 Copy Function Activated
0479 Link not monitored
0583 Unexpected SAM Received 0584 Expected SAM Received
Normal Normal
UAM
Text UAM
Text
0264 REPT-LINK-CGST: congestion level0 to 1
0269 RCVRY-LINK-CGST:congestion hascleared
0265 REPT-LINK-CGST: congestion level1 to 2
0268 RCVRY-LINK-CGST:congestionlevel 2 to 1
SLK Alarms
A-32 EAGLE Unsolicited Alarm and Information Messages Reference
Table A-50 (Cont.) SLK Alarms
0269 RCVRY-LINK-CGST:congestion hascleared
0266 REPT-LINK-CGST: congestion level2 to 3
0267 RCVRY-LINK-CGST:congestionlevel 3 to 2
0269 RCVRY-LINK-CGST:congestion hascleared
0270 REPT-LINK-CGST: discard level 0 to1
0275 RVCRY-LINK-CGST: discard hascleared
0271 REPT-LINK-CGST: discard level 1 to2
0274 RVCRY-LINK-CGST: discard level 2to 1
0275 RVCRY-LINK-CGST: discard hascleared
0272 REPT-LINK-CGST: discard level 2 to3
0273 RVCRY-LINK-CGST: discard level 3to 2
0275 RVCRY-LINK-CGST: discard hascleared
STPLAN AlarmsTable A-51 shows the critical and major STPLAN alarms and the clearing alarm thatappears when each condition is resolved.
Table A-51 STPLAN Alarms
Critical Normal
UAM
Text UAM
Text
0153 STPLAN not available 0150 STPLAN is available
0154 STPLAN is removed
Major Normal
0152 LIM(s) have been denied STPLANservice
0150 STPLAN is available
0154 STPLAN is removed
Minor Normal
0151 STPLAN capacity normal, card(s)abnormal
0150 STPLAN is available
0154 STPLAN is removed
STPLAN Alarms
UAM Balancing Matrix A-33
<subsystem> System AlarmsTable A-52 shows system alarms that may occur for different subystems and theclearing alarm that appears when each condition is resolved. The name of thesubsystem varies.
Table A-52 <subsystem> System Alarms
Critical Normal
UAM
Text UAM
Text
0592 <subsystem> Subsystem is notavailable
0595 <subsystem> Subsystem is available
0594 <subsystem> Subsystem normal,card(s) abnormal
0593 <subsystem> Subsystem is disabled 0596 <subsystem> Subsystem is removed
0594 <subsystem> Subsystem normal,card(s) abnormal
Major Normal
0598 <subsystem> degraded, card(s)abnormal
0595 <subsystem> Subsystem is available
0596 <subsystem> Subsystem is removed
Minor Normal
0594 <subsystem> Subsystem normal,card(s) abnormal
0595 <subsystem> Subsystem is available
0596 <subsystem> Subsystem is removed
System AlarmsTable A-53 shows the critical, major, and minor System alarms and the clearing alarmthat appears when each condition is resolved.
Table A-53 System Alarms
Critical Normal
UAM
Text UAM
Text
0308 Node isolated due to SLK failures 0309 Node is no longer isolated
0368 Temp Keys(s) have expired. 0366 Temp Key(s) expiration alarm cleared
0438 Degraded Mode, Invalid OAM HWconfig
0439 Exiting Degraded Mode
0561 Can't establish Hi Bit rate;All HW OK 0562 Hi Bit rate established
<subsystem> System Alarms
A-34 EAGLE Unsolicited Alarm and Information Messages Reference
Table A-53 (Cont.) System Alarms
Major Normal
0011 Entering forced simplex mode 0018 Exiting forced simplex mode
0367 Temp Keys(s) expiring soon. 0366 Temp Key(s) expiration alarm cleared
0911 Dynamic database is inconsistent 0912 Dynamic database is now consistent
Minor Normal
0302 Cooling fan failure 0303 Cooling fans normal
System GPL AlarmsTable A-54 shows the minor GPL alarms and the clearing alarm that appears wheneach condition is resolved.
Table A-54 System GPL Alarms
Minor Normal
UAM
Text UAM
Text
0143 System release GPL(s) not approved 0142 System release alarm cleared
0144 System release version unknown
T1 Port AlarmsTable A-55 shows the major T1 alarms and the clearing alarm that appears when eachcondition is resolved.
Table A-55 T1 Port Alarms
Major Normal
UAM
Text UAM
Text
0369 REPT-T1F:FAC-T1 unavailable 0380 RCVRY-T1F:FAC-T1 available
0376 REPT-T1F:FAC-T1LOS failure
0377 REPT-T1F:FAC-T1LOF failure
0378 REPT-T1F:FAC-T1 Remote Alarm
0379 REPT-T1F:FAC-T1Alarm
System GPL Alarms
UAM Balancing Matrix A-35
Terminal AlarmsTable A-56 shows the minor Terminal alarm and the clearing alarm that appears whenthe condition is resolved.
Table A-56 Terminal Alarms
Minor Normal
UAM
Text UAM
Text
0048 Terminal failed 0046 Terminal enabled
V-Flex System AlarmsTable A-57 shows the major and minor X-LIST alarms and the clearing alarm thatappears when each condition is resolved.
Table A-57 V-Flex System Alarms
Critical Normal
UAM
Text UAM
Text
0551 V-Flex Subsystem is not available 0554 VFLEX Subsystem is available
0555 VFLEX Subsystem is removed
0552 VFLEX Subsystem is disabled 0554 VFLEX Subsystem is available
0555 VFLEX Subsystem is removed
Major Normal
0556 V-Flex Subsystem degraded, card(s)abnormal
0554 VFLEX Subsystem is available
0555 VFLEX Subsystem is removed
Minor Normal
0553 VFLX Subsystem normal, card(s)abnormal
0554 VFLEX Subsystem is available
0555 VFLEX Subsystem is removed
X-LIST AlarmsTable A-58 shows the major and minor X-LIST alarms and the clearing alarm thatappears when each condition is resolved.
Table A-58 X-LIST Alarms
Major Normal
Terminal Alarms
A-36 EAGLE Unsolicited Alarm and Information Messages Reference
Table A-58 (Cont.) X-LIST Alarms
UAM
Text UAM
Text
0338 X-LIST space full-entry(s) discarded 0339 X-LIST space full condition abated
Minor Normal
0321 X-LIST occupancy thresholdexceeded
0322 X-List occupancy below threshold
X-LIST Alarms
UAM Balancing Matrix A-37
X-LIST Alarms
A-38 Unsolicited Alarm and Information Messages Reference
BUnsolicited Output Message Groups
This appendix provides a list of the unsolicited alarm messages (UAMs) andunsolicited information messages (UIMs) generated by the EAGLE and the outputgroups to which these messages are assigned. The output message groups are shownin alphabetical order.
These messages are broadcast to the EAGLE terminals. To control which terminalsthese messages are broadcast, the messages have been placed into these outputmessage groups. The chg-trm command is used to control to which terminals thesegroups of output messages are broadcast. For details about using the chg-trmcommand, see the “Changing Terminal Characteristics” procedure in DatabaseAdministration - System Management User's Guide, or the chg-trm commanddescription in Commands User's Guide.
Scheduled Measurements for systems up to 700 links are sent to the Traffic UnsolicitedOutput Message Group and are not included in this appendix. No other unsolicitedoutput is sent to this output group. Refer to Measurements Reference for trafficmeasurements information. Refer to System Administration - System Management User'sGuide for information on configuring the measurements terminal for systems up to 700links.
Each table contains the number of the UAM or UIM, the alarm level assigned to themessage, and the text of the message.
Application Subsystem Unsolicited Output Message Group
Table B-1 Application Subsystem Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0283 Major LNP Ported LRNs approaching Feat. Capacity
0284 None LNP Ported LRNs Capacity Normal
0285 Major LNP Ported NPAs approaching Feat. Capacity
0286 None LNP Ported NPAs Capacity Normal
0287 Critical RTDB Table Level 2 FAK Cap Exceeded
0288 Major RTDB Table Level 1 FAK Cap Exceeded
0289 None RTDB Table FAK Capacity Normal
0394 None INP Subsystem is available
0395 Critical INP Subsystem is not available
Unsolicited Output Message Groups B-1
Table B-1 (Cont.) Application Subsystem Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0396 Critical INP Subsystem is disabled
0397 None INP Subsystem is removed
0398 Minor INP Subsystem normal, card(s) abnormal
0424 Critical LNP Subsystem is not available
0425 Minor LNP Subsystem normal, card(s) abnormal
0426 None LNP Subsystem is available
0427 Major LNP Subsystem degraded, card(s) abnormal
0428 Major INP Subsystem degraded, card(s) abnormal
0429 Major ATINPQ Subsystem degraded, card(s) abnormal
0434 None LNP Subsystem is removed
0435 Critical LNP Subsystem is disabled
0436 Major LNPACG node overload
0452 Major Exceeded Service Error Threshold Lvl 1
0453 Critical Exceeded Service Error Threshold Lvl 2
0454 Normal Service Error Threshold Alarm Cleared
0455 Critical EIR Subsystem is not available
0456 Critical EIR Subsystem is disabled
0457 Minor EIR Subsystem normal, card(s) abnormal
0458 None EIR Subsystem is available
0459 None EIR Subsystem removed
0460 Major EIR Subsystem degraded, card(s) abnormal
0500 None Alarm for this entity is being cleared
0526 None Service is available
0527 Minor Service abnormal
0528 Critical Service is not available
0529 Critical Service is disabled
0530 None Service is removed
0547 Major Service degraded
0551 Critical V-Flex Subsystem is not available
Application Subsystem Unsolicited Output Message Group
B-2 EAGLE Unsolicited Alarm and Information Messages Reference
Table B-1 (Cont.) Application Subsystem Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0552 Critical V-Flex Subsystem is disabled
0553 Minor V-Flex Subsystem normal, card(s) abnormal
0554 None V-Flex Subsystem is available
0555 None V-Flex Subsystem is removed
0556 Major V-Flex Subsystem degraded, card(s) abnormal
0565 Critical ATINPQ Subsystem is not available
0566 Critical ATINPQ Subsystem is disabled
0567 Minor ATINPQ Subsystem normal, card(s) abnormal
0568 None ATINPQ Subsystem is available
0569 None ATINPQ Subsystem is removed
0598 Major Subsystem degraded, card(s) abnormal
1030 None Inh EIR SS request already outstanding
1031 None Failure Inhibiting EIR SS
1102 None Invalid Length for Map IMEI Parameter
1103 None LSS:No Map IMEI Parameter present
1121 None LNP rcvd query from unknown CGPA PC
1122 None LNP rcvd query with undefined TT
1123 None LNP rcvd query with Message Relay TT
1124 None SIP: Dgts truncated in 302 response
1139 None DEIROPTS: DEIR Global Response is ON
1140 None DEIROPTS: DEIR Global Response is OFF
1164 None Inh LNP SS request already outstanding
1166 None ACG Node Overload Level Change
1169 None SCCP rcvd inv TCAP portion
1174 None Inh Local SS request already outstanding
1242 None Conv to intl num - Dflt CC not found
1243 None Conv to intl num - Dflt NC not found
1244 None Conv to intl num - Dflt MCC not found
1245 None Conv to intl num - Dflt MNC not found
Application Subsystem Unsolicited Output Message Group
Unsolicited Output Message Groups B-3
Table B-1 (Cont.) Application Subsystem Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
1246 None Invalid length of conditioned digits
1247 None Conversion of MGT to IMSI not possible
1255 None IS-41LNP Qry rejected: WNP is OFF
1256 None NP Circular Route detected
1260 None LSS: Unsupported TCAP msg type
1261 None LSS: Invalid len in transaction portion
1262 None LSS: Invalid len in dialogue portion
1263 None LSS: Invalid len in component portion
1264 None LSS: No originating transaction ID
1265 None LSS: Invalid transaction ID len
1266 None LSS: Destination transaction ID in Begin
1267 None LSS: No External element
1268 None LSS: No External Object Identifier
1269 None LSS: Not Structured Dialogue
1270 None LSS: No External ASN1-Type
1271 None LSS: No Dialogue Request
1272 None LSS: No Application Context Name
1273 None LSS: No ACN Object Identifier
1274 None LSS: No component portion
1275 None LSS: First component not an Invoke
1276 None LSS: No Invoke ID
1277 None LSS: No operation code
1278 None LSS: No parameter (set/sequence)
1279 None LSS: Unsupported network type
1280 None LSS: Unsupported SCCP msg type
1282 None LSS: Unsupported SCCPCDPAGTI
1283 None LSS: Unsupported SCCPCGPARI
1284 None LSS: Unknown SSPPC
Application Subsystem Unsolicited Output Message Group
B-4 EAGLE Unsolicited Alarm and Information Messages Reference
Table B-1 (Cont.) Application Subsystem Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
1285 None LSS: No SCCPCGPASSN
1286 None LSS: Invalid INAP CalledPartyNumber len
1287 None LSS: Unsupported ACN Object ID len
1288 None LSS: Unsupported operation code
1289 None LSS: No parameter sequence
1290 None LSS: No INAP ServiceKey parameter
1291 None LSS: No INAP CalledPartyNumber parameter
1292 None LSS: Parameters out of sequence
1293 None LSS: Linked ID in query
1294 None Invalid digits in MAP MSISDN parameter
1295 None Translation PC is EAGLE's
1296 None Translation PC type is ANSI
1297 None Invalid length of prefix/suffix digits
1298 None SIP message decode failed
1306 None GSMOPTS: EIR Global Response in ON
1307 None GSMOPTS: EIR Global Response in OFF
1342 None ANSIIS-41INP Qry rejected: AINPQ is OFF
1343 None INAPINP Qry rejected: INPQ is OFF
1346 None IS-41 Missing Mandatory Parameters
1347 None IS-41 Digits - Bad Encoding Scheme
1348 None IS-41 Number of dgts exceeds the maximum
1374 None SMS NP Destination address decode failed
SMS B-Party address decode failed
1375 None SMS NP Failed to modify TCAP message
SMS B-Party Failed to modify TCAP MSU
1376 None SMS NP outbound digits length exceeds limit
SMS Failed to modify B-Party digits
1378 None Inh VFlex SS request already outstanding
1379 None Failure Inhibiting VFlex SS
1380 None VFLEX: No RN digits provisioned
Application Subsystem Unsolicited Output Message Group
Unsolicited Output Message Groups B-5
Table B-1 (Cont.) Application Subsystem Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
1381 None VFlex: CD entry not found
1382 None LSS: Too many digits for DRA parameter
1384 None G-Flex MLR: Op without IMSI erroneous
1385 None G-Flex MLR: Op without IMSI skipped
1386 None G-Flex MLR: Op with bad TCAP skipped
1387 None G-Flex MLR: Op with bad IMSI skipped
1395 None Inh ATINPQ SS request alrdy outstanding
1396 None Failure Inhibiting ATINPQ SS
1397 None LSS: Missing Mandatory Parameter
1398 None ATINPQ: Badly formatted Subs Id
1399 None ATINPQ: Subscriber Identity not MSISDN
1400 None LSS: Invalid MSISDN digits length
1401 None LSS: Unsupported numbering plan
1402 None ATINPQ: Invalid Requested Info
1403 None LSS: Dgts truncated in encd parms
1408 None TIF: Modified MSU too large to route
1410 None MOSMS: Migrated Subscriber with no entity
1416 None MAP Missing Mandatory Parameters
1425 None SMS A-party Address decode failed
1426 None S-Port: Missing GRN for srvc prtd subs
1433 None AIQ: Inhibit request already pending
1434 None AIQ: Failure Inhibiting SS
1435 None AIQ: TriggerType not provisioned
1436 None AIQ: : Unsupported Digits(Dialed) length
1439 None SIP card exceeded threshold TPS
1440 None G-Flex MLR: Op with bad MSISDN skipped
1448 None G-Flex MLR: Op w/o IMSI/MSISDN skipped
1450 None IDPRCDPN CDPN Encoding Failed
1451 None IDPRCDPN CGPN Encoding Failed
Application Subsystem Unsolicited Output Message Group
B-6 EAGLE Unsolicited Alarm and Information Messages Reference
Card Unsolicited Output Message Group
Table B-2 Card Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0001 Major Card has reset
0008 Major Active MASP has become isolated
0009 None MASP became active
0010 None MASP became standby
0013 Major Card is isolated from the system
0014 None Card is present
0021 Minor Clock A for card failed, Clock B normal
0022 Minor Clock B for card failed, Clock A normal
0023 Minor Clocks A and B for card failed
0024 None Clock A for card normal
0025 None Clock B for card normal
0026 None Clocks A and B for card normal
0030 Minor HIPR2 detected a minor Congested Second
0031 Major HIPR2 detected a major Congested Second
0032 None HIPR2 Congestion cleared
0033 None Card database has been corrected
0034 Minor Card database is inconsistent
0035 Minor Card database is corrupted
0036 None Card backup database has been corrected
0037 Minor Card backup database is inconsistent
0038 Minor Card backup database is corrupted
0053 Major Standby TDM failure
0054 None Standby TDM failure cleared
0055 Minor Persistent device state tbl corrupt
0056 Minor Persistent device state tbl diff version
0057 None Persistent device state tbl corrected
0077 Critical Card temperature is critical lvl:T2
Card Unsolicited Output Message Group
Unsolicited Output Message Groups B-7
Table B-2 (Cont.) Card Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0078 Major Card temperature above nominal
0079 None Card temperature within nominal levels
0080 Major Shelf FAN bit is OFF
0081 None Shelf FAN bit is ON
0092 Critical MDAL not responding
0093 None MDAL alarm cleared
0096 None Card has been reloaded
0099 Major Incompatible HW for provisioned slot
0102 Minor Motherboard BIP invalid
0103 None Motherboard BIP valid
0124 Minor ENUM Threshold -Level1 exceeded
0125 Major ENUM Threshold -Level2 exceeded
0126 Normal ENUM Threshold Condition cleared
0127 Critical ENUM card capacity exceeded
0129 Normal ENUM card TPS is normal
0130 None Card successfully loaded with data
131 None HW alarm cleared for Intgd Measurements
0132 Major Loading failed: table not found
0133 Major Loading failed: data read Error
0134 Major Loading failed: bad checksum returned
0135 Major Loading failed: GPL load timeout
0136 Major Loading failed: data load timeout
0137 Major Loading failed: invalid GPL
0138 Major Loading failed: GPL format error
0139 Major Loading failed: disk read prep error
0140 Major Loading failed: disk read response error
0141 Major Loading failed: disk read failed
0145 Minor HS Clock A for card failed, B normal
0146 Minor HS Clock B for card failed, A normal
0147 Minor High Speed Clocks A & B for card failed
Card Unsolicited Output Message Group
B-8 EAGLE Unsolicited Alarm and Information Messages Reference
Table B-2 (Cont.) Card Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0148 None High Speed Clock A for card normal
0149 None High Speed Clock B for card normal
0159 None High Speed Clocks A & B for card normal
0297 Major Incorrect LIM port configuration
0298 Minor Card not using config. SCTP csum method
0299 None Config. SCTP csum method alarm cleared
0300 Major TVG Grant Failure
0301 None TVG Grant Recovery
0400 None Alarm cleared by deleting card
0422 Major Insufficient memory for LNP
0423 None Card reload attempted
0441 Major Incorrect MDB - CPU
0442 Critical RTDB database capacity is 95% full
0443 Major RTDB database is corrupted
0444 Minor RTDB database is inconsistent
0445 None RTDB database has been corrected
0446 Major RTDB database capacity is 80% full
0447 None RTDB database memory alarm cleared
0448 Minor RTDB database is incoherent
0449 Major RTDB resynchronization in progress
0450 Major Invalid HW for Integrated GLS
0451 Major RTDB reload is required
0452 Major Exceeded Service Error Threshold Lvl1
0453 Critical Exceeded Service Error Threshold Lvl 2
0454 None Service Error Threshold Alarm Cleared
0486 Minor DEIR Threshold - Level1 exceeded
0487 Major DEIR Threshold - Level2 exceeded
0488 Normal DEIR Threshold Condition Cleared
0489 Critical DEIR capacity exceeded
Card Unsolicited Output Message Group
Unsolicited Output Message Groups B-9
Table B-2 (Cont.) Card Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0490 Normal DEIR normal
0500 None Alarm for this entity is being cleared
0548 Major GTT HexTree DB corrupted. TPS derated
0549 Major GTT HexTree DB incoherent. TPS derated
0550 Normal GTT HexTree DB alarm cleared
0570 Minor Incompatible flash image for sys rel
0573 Major BERT Test Failed
0574 None BERT Test Passed
0575 Major Card type not HIPR2
0622 Minor SIP Threshold - Level1
0623 Major SIP Threshold - Level2
0624 None SIP Threshold condition cleared
0625 None SIP SYSTEM normal, card(s) abnormal
0626 None SIP Threshold Level Critical
0901 Major CardDB load timeout, check GLS card
0902 None CardDB is stable
0903 Major IPLink A is down
0904 None IPLink A is up
0905 Major IPLink B is down
0906 None IPLink B is up
0907 None HW limiting TPS rate alarm cleared
0908 Major HW cannot support purchased TPS rate
1082 None Amem single bit error report
1119 None Cards out of phase with flash procedure
1141 None AIN INP Qry rejected: AINPQ is OFF
1158 None Minor HIPR2 switching capacity reached
1159 None Major HIPR2 switching capacity reached
1238 None Full database reload initiated
1241 None SCCP Card logging capacity exceeded
1298 None SIP message decode failed
Card Unsolicited Output Message Group
B-10 EAGLE Unsolicited Alarm and Information Messages Reference
Table B-2 (Cont.) Card Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
1453 None EE Collection started
1454 None EE Collection end
1455 None EE Queue Full, Package dropped
1456 None Hub Congested, Package dropped
1457 None GEDTI Port enabled
1458 None GEDTI Port disabled
1459 None TCP Connection lost b/w IPSM and EEPC
1462 None EE not configured
1472 None SCTP Buffer full timer expired, Restart
1473 None Unable to connect to socket
1474 None GTT DB reload initiated
Clock Unsolicited Output Message Group
Table B-3 Clock Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0113 None Clock alarm(s) cleared
0128 Critical All clocks have failed
0160 Minor 1116-S clock failed
0161 Minor 1116-P clock failed
0162 Major 1116-P, 1116-S clocks failed
0163 Minor 1114-S clock failed
0164 Major 1114-S, 1116-S clocks failed
0165 Minor 1114-S, 1116-P clocks failed
0166 Major 1114-S, 1116-P, 1116-S clocks failed
0167 Minor 1114-P clock failed
0168 Minor 1114-P, 1116-S clocks failed
0169 Major 1114-P, 1116-P clocks failed
0170 Major 1114-P, 1116-P, 1116-S clocks failed
0171 Major 1114-P, 1114-S clocks failed
Clock Unsolicited Output Message Group
Unsolicited Output Message Groups B-11
Table B-3 (Cont.) Clock Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0172 Major 1114-P, 1114-S, 1116-S clocks failed
0173 Major 1114-P, 1114-S, 1116-P clocks failed
0183 Minor 1116-SHS clock failed
0184 Minor 1116-PHS clock failed
0185 Major 1116-PHS, 1116-SHS clocks failed
0186 Minor 1114-SHS clock failed
0187 Major 1114-SHS, 1116-SHS clocks failed
0188 Minor 1114-SHS, 1116-PHS clocks failed
0189 Major 1114-SHS, 1116-PHS, 1116-SHS clks failed
0190 Minor 1114-PHS clock failed
0191 Minor 1114-PHS, 1116-SHS clocks failed
0192 Major 1114-PHS, 1116-PHS clocks failed
0193 Major 1114-PHS, 1116-PHS, 1116-SHS clks failed
0194 Major 1114-PHS, 1114-SHS clocks failed
0195 Major 1114-PHS, 1114-SHS, 1116-SHS clks failed
0196 Major 1114-PHS, 1114-SHS, 1116-PHS clks failed
0197 Critical All High Speed Clocks have failed
0198 None High Speed Clock Alarm(s) Cleared
0403 Major 1114 E1/T1 clock requires TDM-GTI
0404 Major 1116 E1/T1 clock requires TDM-GTI
0405 Major 1114, 1116 E1/T1 clock requires TDM-GTI
0406 Major 1114 Clock selection mismatch
0407 Major 1116 Clock selection mismatch
0408 Major 1114, 1116 Clock selection mismatch
0409 None Clock configuration corrected
0500 None Alarm for this entitiy is being cleared
1185 None GTI input clock anomalies detected
Clock Unsolicited Output Message Group
B-12 EAGLE Unsolicited Alarm and Information Messages Reference
Database Unsolicited Output Message Group
Table B-4 Database Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
1114 None DatabaseBACKUP started
1115 None DatabaseRESTORE started
1116 None Database action ended - OK
1117 None Database action ended - FAIL
1257 None DB restore has cleared and Disabled PDS
GTT Unsolicited Output Message Group
Table B-5 GTT Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0262 Major GTT Duplicate Actn processing stopped
0263 None GTT Duplicate Actn processing resumed
0328 None SCCP is available
0329 None SCCP capacity normal, card(s) abnormal
0330 Major System SCCP TPS Threshold exceeded
0331 Critical SCCP is not available
0335 None SCCP is removed
0336 Major LIM(s) have been denied SCCP service
0437 Critical System SCCP TPS Capacity Exceeded
0500 None Alarm for this entity is being cleared
0630 Major Throttle Threshold - exceeded
0631 None Throttle Threshold - cleared
0632 Minor Alarm Threshold - exceeded
0633 None Alarm Threshold - cleared
1019 None SCCP rcvd invalid UDTS/XUDTS msg
1020 None IARCDPN NPP Service is off
1021 None IARCGPN NPP Service is off
1023 None SCCP rcvd unknown msg type
Database Unsolicited Output Message Group
Unsolicited Output Message Groups B-13
Table B-5 (Cont.) GTT Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
1024 None SCCP rcvd inv msg length
1025 None SCCP rcvd inv msg class
1029 None SCCP rcvd inv Cld Party - bad GT ind
1033 None SCCP rcvd inv Cld Party - bad network
1034 None SCCP rcvd inv Cld Party - no SSN
1035 None SCCP rsp did not route - invalid GTI
1036 None SCCP rsp did not route - invalid TT
1037 None SCCP rsp did not route - bad Xlation
1038 None SCCP rsp did not route - SSP not True PC
1039 None SCCP rsp did not route - bad Selectors
1040 None ITU <-> ANSI translation not supported
1041 None SCCP did not route - no SSN in msg or DB
1042 None SCCP rcvd inv GT - invalid Trans. Type
1043 None SCCP did not route - bad translation
If the UIMRD field in rtrv-stpopts is set to yes, this message isoutput in the UIM Redirect output group (see Table B-16).
1044 None SCCP did not route - DPC OOS
1045 None SCCP did not route - DPC congested
1046 None SCCP did not route - DPC not in MAP tbl
If the UIMRD field in rtrv-stpopts is set to yes, this message isoutput in the UIM Redirect output group (see Table B-16).
1047 None SCCP did not route - SS OOS
1048 None SCCP did not route - SS congested
1049 None SCCP did not route - SS not in MAP tbl
1050 None SCCP-CNV: Unable to convert ANSICDPAGT
1051 None SCCP-CNV: Unable to convert ANSICGPAGT
1052 None SCCP-CNV: Unable to convert ITUCDPAGT
1053 None SCCP-CNV: Unable to convert ITUCGPAGT
1054 None SCCP rcvd inv LSS - bad SSN
1055 None SCCP rcvd inv SCMG - bad AFTPC
GTT Unsolicited Output Message Group
B-14 EAGLE Unsolicited Alarm and Information Messages Reference
Table B-5 (Cont.) GTT Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
1056 None SCCP rcvd inv SCMG - bad subsystem
1057 None SCCP rcvd inv SCMG - bad length
1058 None SCCP rcvd inv SCMG - bad msg type
1063 None SCCP screen set is too large
1077 None GTT Action TCAP ERROR DISCARDED MSU
1078 None GTT Action DUPLICATE FAILED
1079 None GTT Action FORWARD FAILED
1107 None SCCPXUDT (S) msg: Hop Counter violation
1108 None SCCPXUDT (S) msg: inv opt portion len
1109 None XUDT(S) msg: inv segmentation parm
1143 None GTT(FLOBR) failure: duplicate settype
1144 None GTT(FLOBR) warning: duplicate settype
1145 None MBR decoding failed
1178 None Cnvrsn Discard: Invalid SCCP msg type
1179 None Cnvrsn Discard: CGPA PC alias undefined
1180 None Cnvrsn Discard: Aft. PC alias undefined
1181 None Cnvrsn Discard: Invalid SCMG msg type
1182 None Cnvrsn Discard: Invalid TCAP element
1183 None Cnvrsn Discard: Invalid TCAP element len
1189 None SCCP did not route: DPC not in RTE table
1190 None SCCP rcvd inv Clg Party - bad GT ind
1191 None SCCP rcvd inv Clg Party - bad selectors
1192 None GTT Action UDTS DISCARDED MSU
1193 None GTT Action DISCARD DISCARDED MSU
1195 None SCCP did not route: DPC/SS not in Mapset
1219 None SCCP rcvd inv Cld Party - bad GT ind
1220 None SCCP rcvd inv Cld Party - bad network
1221 None SCCP rcvd inv Cld Party - no SSN
1222 None SCCP rcvd inv Cld Party - bad Selectors
GTT Unsolicited Output Message Group
Unsolicited Output Message Groups B-15
Table B-5 (Cont.) GTT Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
1223 None SCCP rcvd inv Cld Party - bad Xlation
1224 None SCCP rcvd inv Cld Party - bad SSN
1225 None SCCP did not route - DPC OOS
1226 None SCCP did not route - DPC congested
1227 None SCCP did not route - DPC not in MAP tbl
1228 None SCCP did not route - SS OOS
1229 None SCCP did not route - SS congested
1230 None SCCP did not route - SS not in MAP tbl
1231 None SCCP Encode Failure
1232 None SCCP Encode Failure 2
1240 None MAP SCCP Validation Fail
1248 None GSM Map Screening rcvd unknown orig
1249 None SCCP rcvd GSM Map Opcode w/ forbid param
1250 None SCCP rcvd undefined Map Op-Code
1341 None SRI rcvd - GSM2IS41not provisioned
1344 None MSU discarded: In-Service Thresholding
1388 None Invalid prefix/suffix digit len for CdPA
1389 None Invalid prefix/suffix digit len for CgPA
1392 None IDPRCDPN(X) NPP SERVICE is OFF
1393 None IDPRCGPN NPP SERVICE is OFF
1412 None GTT(FLOBR) failure: max search depth
1413 None GTT(FLOBR) failure: duplicate set name
1414 None GTT(FLOBR) warning: max search depth
1415 None GTT(FLOBR) failure: duplicate set name
1418 None SCCP did not route - no SSN in CgPA
1419 None SCCP did not route - no SSN in CdPA
1427 None IAR CdPN parameter invalid or not found
1428 None IAR CgPN parameter invalid or not found
1429 None IAR TRIGTYPE invalid or not found
GTT Unsolicited Output Message Group
B-16 EAGLE Unsolicited Alarm and Information Messages Reference
Table B-5 (Cont.) GTT Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
1430 None IAR CdPN parameter encoding failed
1431 None IAR CgPN parameter encoding failed
1443 None GTT Action FAILED TO SEND TCAP ERROR
1444 None GTT Loadsharing fail: PC not in MRNSET
1446 None XUDT UDT conversion failed
1447 None Cnvrsn Discard: inv segmentation parm
1475 None TOBR Multiple Comp: Translation found
1476 None TCAPMulComp: Dup Opcode MSU discarded
Gateway Screening Unsolicited Output Message Group
Table B-6 GWS Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0290 None GLS is available
0291 Major GLS is at minimum service limit
0292 Critical GLS is not available
0293 None GLS have been removed from the system
0500 None Alarm for this entitiy is being cleared
1005 None GWS rcvd OPC that is not allowed
1006 None GWS rcvd DPC that is not allowed
1007 None GWS rcvd OPC that is blocked
1008 None GWS rcvd DPC that is blocked
1009 None GWS rcvd SIO that is not allowed
1010 None GWS rcvd a priority that is not allowed
1011 None GWS rcvd TFC, AFTPC not in routing tbl
1012 None GWS rcvd Clg Party that is not allowed
1013 None GWS rcvd Cld Party that is not allowed
1014 None GWS rcvd Translation Type not allowed
1015 None GWS rcvd SCMG with not allowed AFTPC
Gateway Screening Unsolicited Output Message Group
Unsolicited Output Message Groups B-17
Table B-6 (Cont.) GWS Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
1060 None Map Screening cannot generate ATIERR
1062 None Text string with screen set name & line #( <screen set name>too large)
1064 None GWS rcvd TFP, AFTPC not in routing tbl
1065 None GWS rcvd TFR, AFTPC not in routing tbl
1066 None GWS rcvd TFA, AFTPC not in routing tbl
1067 None GWS rcvd UPU, AFTPC not in routing tbl
1068 None GWS rcvd RSP, AFTPC not in routing tbl
1069 None GWS rcvd RSR, AFTPC not in routing tbl
1110 None GWS rcvd AFTPC that is not allowed
1111 None GWS rcvd TCA, AFTPC not in routing tbl
1112 None GWS rcvd TCR, AFTPC not in routing tbl
1113 None GWS rcvd TCP, AFTPC not in routing tbl
1125 None GWS rcvd CDPA that could not be RDCTd
1126 None GWS rcvd CGPA that could not be RDCTd
1127 None GWS rcvd AFTPC that could not be RDCTd
1128 None GWS rcvd TT that could not be RDCTd
1142 None GWS Strip Stop Action Failed
1161 None GWS rcvd nonSNM msg in DESTFLD screening
1162 None GWS rcvd nonSCCP msg in CGPA/CDPA screen
1163 None GWS rcvd invalid GTI in TT screening
1215 None GWS rcvd CDPA that could not be CNCFd
1216 None GWS rcvd CGPA that could not be CNCFd
1217 None GWS rcvd AFTPC that could not be CNCFd
1218 None GWS rcvd TT that could not be CNCFd
1258 None Map Screening cannot Forward MSU
1259 None Map Screening cannot Duplicate MSU
1301 None SECMTPMATE - rcvd mate PC on non C-link
1302 None SECMTPSID - rcvd MSU with OPC = SID
Gateway Screening Unsolicited Output Message Group
B-18 EAGLE Unsolicited Alarm and Information Messages Reference
Table B-6 (Cont.) GWS Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
1303 None SECMTPSNM - no rte to OPC/AFTPC
1304 None SECSCCPSCMG - no rte to AFTPC
1407 None Unexpected SI in TIF Stop Action
1449 None Binding Failed for screen set: <screen set name>
1460 None GWS Duplicate Stop Action Failed
Link Maintenance Unsolicited Output Message Group
Table B-7 Link Maintenance Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0084 Major IP Connection Unavailable
0085 None IP Connection Available
0086 Minor IP Connection Congested
0087 None IP Connection manually removed
0115 Major Linkset IP TPS threshold exceeded
0116 Minor Link expected IP TPS threshold exceeded
0118 None Linkset IP TPS normal
0119 None LinkIPTPS normal
0200 None RCVRY-LKF: link available
0201 Major REPT-LKF: remote NE loopback
0202 Major REPT-LKF: HWP - too many link interrupts
0203 Major REPT-LKF: lost data
0204 Major REPT-LKF: XER - SUERM threshold exceeded
0205 Major REPT-LKF: APF - lvl-2 T1 expd (ready)
0206 Major REPT-LKF: APF - lvl-2 T1 expd (not ready)
0207 Major REPT-LKF: APF - lvl-2 T3 expired
0208 Major REPT-LKF: APF - lvl-2 T2 expired
0209 Major REPT-LKF: APF - failed proving period
0210 Major REPT-LKF: OSA - received SIO
Link Maintenance Unsolicited Output Message Group
Unsolicited Output Message Groups B-19
Table B-7 (Cont.) Link Maintenance Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0211 Major REPT-LKF: OSA - received SIN
0212 Major REPT-LKF: OSA - received SIE
0213 Major REPT-LKF: OSA - received SIOS
0214 Major REPT-LKF: ABN - rcvd 2 of 3 invalid BSN
0215 Major REPT-LKF: ABN - rcvd 2 of 3 invalid FIB
0216 Major REPT-LKF: remote congestion timeout
0217 Major REPT-LKF: excess acknowledge delay
0218 Major REPT-LKF: COO - rcvd changeover order
0219 Major REPT-LKF: false congestion restart
0220 Major REPT-LKF: MTP link restart delayed
0222 Major REPT-LKF: remote FE loopback
0223 None REPT-LKF: remote NE loopback cleared
0224 Major REPT-LKF: link test failed
0230 Major REPT-LKF: local blocked - thermal
0232 Major REPT-LKF: remote blocked
0233 Major REPT-LINK-MANUAV: local blocked
0234 Major REPT-LKF: RMI remote inhibited
0235 Major REPT-LINK-MGTINH: local inhibited
0236 Major REPT-LKF: not aligned
0237 Major REPT-LKF: LM Timer NO-CREDIT expired
0238 Major REPT-LKF: XDA-Timer NO-RESPONSE expired
0239 Major REPT-LKF: MBL - local processor outage
0240 Major REPT-LKF: rcvd remote processor outage
0241 Major REPT-LKF: rcvd remote out of service
0242 Major REPT-LKF: rcvd remote protocol error
0243 Major REPT-LKF: rcvd remote mgmnt initiated
0244 Major REPT-LKF: FAC - DS1/E1 LOS failure
0245 Major REPT-LKF: FAC - DS1/E1 LOF failure
Link Maintenance Unsolicited Output Message Group
B-20 EAGLE Unsolicited Alarm and Information Messages Reference
Table B-7 (Cont.) Link Maintenance Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0246 Major REPT-LKF: FAC - DS1/E1 LCD failure
0247 Major REPT-LKF: XER - ISERM threshold exceeded
0264 None REPT-LINK-CGST: congestion level 0 to 1
0265 None REPT-LINK-CGST: congestion level 1 to 2
0266 None REPT-LINK-CGST: congestion level 2 to 3
0267 None RCVRY-LINK-CGST: congestion level 3 to 2
0268 None RCVRY-LINK-CGST: congestion level 2 to 1
0269 None RCVRY-LINK-CGST: congestion has cleared
0270 None REPT-LINK-CGST: discard level 0 to 1
0271 None REPT-LINK-CGST: discard level 1 to 2
0272 None REPT-LINK-CGST: discard level 2 to 3
0273 None RCVRY-LINK-CGST: discard level 3 to 2
0274 None RCVRY-LINK-CGST: discard level 2 to 1
0275 None RCVRY-LINK-CGST: discard has cleared
0304 Minor REPT-NMTSK-DSCD: SNM Discard Onset
0305 None RECVY-NMTSK-DSCD: SNM Discard Abated
0306 Minor SNM Overload Onset
0307 None SNM Overload Abated
0311 None DPC is allowed
0312 Minor DPC is restricted
0313 Critical DPC is prohibited
0314 None Route is allowed
0315 None Route is restricted
0316 None Route is prohibited
0317 None RCVRY-LKSTO: link set allowed
0318 Major REPT-LKSTO: link set prohibited
0319 Critical REPT-MTPLP-DET: Circ rte det(cong)
0320 Critical REPT-MTPLP-SUST: Sustained circ rte(cong)
Link Maintenance Unsolicited Output Message Group
Unsolicited Output Message Groups B-21
Table B-7 (Cont.) Link Maintenance Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0321 Minor X-LIST occupancy threshold exceeded
0322 None X-LIST occupancy below threshold
0324 None DPC subsystem is allowed
0325 Critical DPC subsystem is blocked
0326 Critical DPC subsystem is prohibited
0327 None DPC subsystem has been deleted
0332 Critical DPC Subsystem is prohibited and blocked
0333 None DPC Subsystem is Normal
0334 Critical DPC Subsystem is Abnormal
0337 None DPC-SS status changed
0338 Major X-LIST space full-entry(s) discarded
0339 None X-LIST space full condition abated
0340 None RCVRY-MTPLP-RST:Circ rte status cleared
0369 Major REPT-T1F:FAC-T1 unavailable
0376 Major REPT-T1F:FAC-T1LOS failure
0377 Major REPT-T1F:FAC-T1LOF failure
0378 Major REPT-T1F:FAC-T1 Remote Alarm
0379 Major REPT-T1F:FAC-T1Alarm
0380 None RCVRY-T1F:FAC-T1 available
0381 Major REPT-E1F:FAC-E1LOS failure
0382 Major REPT-E1F:FAC-E1LOF failure
0383 Major REPT-E1F:FAC-E1AIS detected
0384 Major REPT-E1F:FAC-E1 Far End Failure
0385 Major REPT-E1F:FAC-E1 10E-3 BER failed
0386 None RCVRY-E1F:FAC-E1 available
0387 Major REPT-E1F:FAC-E1 unavailable
0399 None RCVRY-LKSTO: Alarm clr'd by deleting SLK
0401 None Alarm cleared by deleting SLK
Link Maintenance Unsolicited Output Message Group
B-22 EAGLE Unsolicited Alarm and Information Messages Reference
Table B-7 (Cont.) Link Maintenance Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0402 None Alarm cleared by deleting route
0491 Major Connection TPS exceeded
0492 Normal Connection TPS normal
0493 Major Diameter Connection Down
0494 Normal Diameter Connection Up
0495 Normal Diameter Connection Closed
0497 Major REPT-J1F:FAC-J1 LOS failure
0498 Major REPT-J1F:FAC-J1 LOF failure
0499 Major REPT-J1F:FAC-J1 Remote Alarm
0500 None Alarm for this entity is being cleared
0504 Major REPT-J1F:FAC-J1 Alarm
0505 Normal RRCVRY-J1F:FAC-J1 available
0506 Major REPT-J1F:FAC-J1 unavailable
0532 None RTX is allowed
0533 Minor RTX is restricted
0534 Critical RTX is prohibited
0535 Minor IP Connection Restricted
0537 Major Ethernet error threshold exceeded
0538 None Ethernet error threshold cleared
0539 Major Ethernet Interface Down
0540 None Ethernet Interface Up
0560 Minor REPT-LKSTO: link set restricted
1016 None MTP Adj PC not in routing table
1018 None REPT-MTPERR: MTP received - invalid SIO
1070 None SLTC failure: invalid Point Code (OPC)
1071 None SLTC failure: invalid SLC
1072 None SLTC failure: no response
1073 None SLTC failure: bad data pattern
1075 None MTP: link bypassed SLT phase
1076 None SLTC failure: invalid Point Code (DPC)
Link Maintenance Unsolicited Output Message Group
Unsolicited Output Message Groups B-23
Table B-7 (Cont.) Link Maintenance Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
1081 None MTP: Changeback T5 timeout
1084 None GWSMSU discarded by redirect function
1085 None GWSMSU too large to be redirected
1086 None LFS test terminated with OAM switch over
1087 None MTPRSTRT rcvd unexpected user traffic
1088 None REPT-MTP-RSTRT: MTP Restart started
1089 None RCVRY-MTP-RSTRT: MTP Restart Completed
1090 None ITUGWY:CPC conversion failure
1091 None ITUGWY:OPC conversion failure
1092 None ITUGWY:H0H1 conversion failure
1093 None ITUGWY:rcvd msg type cannot convert
1094 None ITUGWY:Invalid ISUP msg structure
1095 None ITUGWY:GRS buffer full
1096 None ITUGWY:RSC buffer full
1097 None ITUGWY:CGB buffer full
1100 None GWS rcvd H0/H1 that is not allowed
1104 None IP Connection Failed
1133 None Diameter msg decode failed
1134 None Diameter msg encode failed
1135 None Invalid Diameter msg received
1136 None Invalid Diameter msg length
1137 None Diameter AVP decode failed
1138 None Connection Refused
1146 None REPT-XLST-TIMO: X-LIST entry expired
1147 None MTP Invalid TFA received
1148 None MTP Invalid TFR received
1149 None SLK Level-3 T19 timer expired
1150 None SLK Inhibit denied
Link Maintenance Unsolicited Output Message Group
B-24 EAGLE Unsolicited Alarm and Information Messages Reference
Table B-7 (Cont.) Link Maintenance Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
1151 None SLK Inhibit response timeout
1152 None SLK Uninhibit denied
1153 None SLK Uninhibit response timeout
1154 None MSU-received threshold exceeded
1155 None MSU-rejected threshold exceeded
1160 None GWS rcvd ISUP that is not allowed
1167 None SIP connection established
1168 None SIP connection terminated
1172 None REPT-OVSZMSG: SCCPMSU too large to route
1173 None REPT-OVSZMSG: MTPMSU too large to route
1177 None Cnvrsn Discard: SCCP MSU too large
1184 None Cnvrsn Discard: Invalid SCCP element len
1233 None MTP Invalid ITU TFR RCVD
1305 None MTP rcvd UPU-User SCCP, Cause invalid
1332 None Invalid Initial M2PA FSN Received
1350 None Discrd Rcvd Lrg MSU CTRL-FEAT Off
1351 None Discrd Trans Lrg MSU Unsupported SLK
1352 None Discrd Rcvd Lrg MSU Unsptd Outbnd SLK
1353 None DTA Bypassed for Rcvd Lrg MSU
1354 None STPLAN Copy Bypassed for Lrg MSU
1357 None Negotiation at 100Mbps/Full Duplex failed
1358 None MSU discarded - too big after MTP conv.
1372 None SLTC Failure-SLTM not sent, Invalid SIO
1394 None Flushing undelivered MSUs
1442 None Invalid EMP SCR Message Received
1452 None Invalid IP Address From SCTP Heartbeat Response
Link Maintenance Unsolicited Output Message Group
Unsolicited Output Message Groups B-25
Measurements Maintenance Unsolicited Output Message Group
Table B-8 Measurements Maintenance Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0012 Major Invalid HW for Integrated Measurements
0500 None Alarm for this entitiy is being cleared
0516 Minor Degraded Mode - 1 card failed
0517 Major Degraded Mode - multiple cards failed
0518 Critical Measurements subsystem unavailable
0519 None Measurements subsystem available
1022 None System Meas limit exceeded for LSONISMT
1026 None System Meas. limit exceeded for LSORIGNI
1027 None System Meas. limit exceeded for LSDESTNI
1028 None System Meas. limit exceeded for ORIGNET
1061 None Meas sync not allowed from old version
1080 None disk measurement status unreadable
1186 None Meas data load failure: old version
1199 None LNPDTH Measurements Discarded for DPC
1234 None LNP Day Meas. Discarded for NPANXX
1251 None Measurements data copy failure
1252 None Report generation failure
1253 None Report transfer failure FTP Server
1254 None Scheduled transer failure
1310 None System Meas. Limit exceeded for LRN
1311 None System Meas. Limit exceeded for NPANXX
1417 None PublicKey doesn’t match known-host file
1445 None LNP Day Meas. Discarded for LRN
Measurements Maintenance Unsolicited Output Message Group
B-26 EAGLE Unsolicited Alarm and Information Messages Reference
Monitor Unsolicited Output Message Group
Table B-9 Monitor Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0051 Major TSC sync is in simplex mode
0052 None TSC sync feature is available
0088 Major Clocks A and B TSCs are out of sync
0089 None Clocks A and B TSCs are resynchronized
0468 Critical All STC Networks Unavailable
0469 Critical All STC Cards Unavailable
0470 None EROUTE is Removed
0471 None EROUTE System is Available
0472 Minor EROUTE System Threshold Exceeded
0473 Major EROUTE System Capacity Exceeded
0474 None EROUTE capacity normal card(s) abnormal
0475 Minor NTP Time Unavailable
0476 None NTP Time Available
0477 Minor Congestion: Copy Function De-activated
0478 None Copy Function Activated
0479 None Link not Monitored
0480 Minor Timestamp Invalid
0481 None Timestamp Valid
0482 Major Card(s) have been denied EROUTE service
0500 None Alarm for this entitiy is being cleared
0531 Minor Insufficient HW Copy Function Inhibited
0571 Minor Sentinel socket is inactive
0572 None Sentinel socket is active
0576 Major All FC Network Unavailable
0577 None All FC cards removed
0578 None FC System is Available
0579 Minor FC Network Unavailable
Monitor Unsolicited Output Message Group
Unsolicited Output Message Groups B-27
Table B-9 (Cont.) Monitor Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0580 None FC Network Available
0581 Minor Loss of heartbeat
0582 None Heartbeat Available
0583 Minor Unexpected SAM Received
0584 None Expected SAM Received
0588 Major FC Port De-activated
0589 None FC Port Activated
0590 Minor Fast Copy Application De-activated
0591 None Fast Copy Application Activated
0597 Minor FC System is Deactivated
MPS Unsolicited Output Message Group
Table B-10 MPS Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0041 Critical LNPDB Maintenance required
0042 None LSMS bulk load complete
0250 None MPS available
0261 Critical MPS unavailable
0355 None LSMS is available
0356 Critical LSMS unavailable
0357 None All OAP terminals are removed
0358 Major LSMS connection unavailable
0359 None LSMS connection available
0362 Major LSMS is at min service limit
0370 Critical Critical Platform Failure(s)
0371 Critical Critical Application Failure(s)
0372 Major Major Platform Failure(s)
0373 Major Major Application Failure(s)
MPS Unsolicited Output Message Group
B-28 EAGLE Unsolicited Alarm and Information Messages Reference
Table B-10 (Cont.) MPS Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0374 Minor Minor Platform Failure(s)
0375 Minor Minor Application Failure(s)
0500 None Alarm for this entitiy is being cleared
Program Update Unsolicited Output Message Group
Table B-11 Program Update Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
1083 None REPTCOND: system alive
SEAS Maintenance Unsolicited Output Message Group
Table B-12 SEAS Maintenance Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0341 Major OAP unavailable
0342 Major SEASUAL unavailable
0343 Major SEAS X.25 Link unavailable
0344 Minor SEASPVC unavailable
0345 Major All SEAS UAL sessions unavailable
0346 Minor SEASUAL session unavailable
0347 None SEAS X.25 Link is available
0348 Major SEAS is at min service limit
0349 Critical SEAS unavailable
0350 Critical OAP terminals inhibited
0351 None SEAS is available
0352 None SEAS is removed
0353 None OAP is available
0354 Major One OAP terminal unavailable
0360 Major EMS Agent unavailable
0361 None EMS Agent available
Program Update Unsolicited Output Message Group
Unsolicited Output Message Groups B-29
Table B-12 (Cont.) SEAS Maintenance Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0363 Minor OAP filesystem full
0364 Minor Config. data checksum mismatch
0365 None Config. data checksum alarm cleared
0500 None Alarm for this entitiy is being cleared
1099 None Text string that was received from the OAP
Security Administration Unsolicited Output Message Group
Table B-13 Security Administration Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0174 Minor %full threshold reached - upload required
0175 Minor LOGBUFROVFL-SECULOG -upload required
0176 Minor Stdby security log -- upload required
0177 None Security log exception cleared
0178 None Security log failed
0199 None OA&M IP Security feature disabled
0500 None Alarm for this entitiy is being cleared
1493 None SSH Host Keys Regenerated
1494 None SSH Host Keys Loaded
SLAN Maintenance Unsolicited Output Message Group
Table B-14 SLAN Maintenance Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0150 None STPLAN is available
0151 Minor STPLAN capacity normal, card(s) abnormal
0152 Major LIM(s) have been denied STPLAN service
0153 Critical STPLAN not available
0154 None STPLAN is removed
0155 Minor STPLAN connection unavailable
Security Administration Unsolicited Output Message Group
B-30 EAGLE Unsolicited Alarm and Information Messages Reference
Table B-14 (Cont.) SLAN Maintenance Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
0156 None STPLAN connection available
0500 None Alarm for this entitiy is being cleared
1132 None STPLANDLK ping test completed
System Maintenance Unsolicited Output Message Groups
Table B-15 System Maintenance Unsolicited Output Message Groups
UAM/UIMNumber
Alarm Level Message Text
0002 Minor Card is not running approved GPL
0003 None Alarm cleared for GPL
0004 Minor Card is running non-activated GPL
0005 None Alarm cleared running non-activated GPL
0011 Major Entering forced simplex mode
0018 None Exiting forced simplex mode
0027 Minor IMT Bus util rate exceeds minor thresh
0028 Major IMT Bus util rate exceeds major thresh
0029 None IMT Bus utilization threshold cleared
0039 None GPL has been corrected
0040 Minor GPL is corrupted
0043 Major Incorrect feature configuration
0044 Minor Real time clock battery low
0045 None Real time clock battery restored
0046 None Terminal enabled
0047 Major Card type not valid for application
0048 Minor Terminal failed
0058 Critical Critical customer trouble detected
0059 Major Major customer trouble detected
0060 Minor Minor customer trouble detected
0061 None Customer trouble detected
System Maintenance Unsolicited Output Message Groups
Unsolicited Output Message Groups B-31
Table B-15 (Cont.) System Maintenance Unsolicited Output Message Groups
UAM/UIMNumber
Alarm Level Message Text
0062 None Customer trouble cleared
0063 Critical Critical holdover clock trouble detected
0064 Major Major holdover clock trouble detected
0065 Minor Minor holdover clock trouble detected
0066 None Holdover clock trouble cleared
0077 Critical Card temperature is critical lvl:T2
0078 Major Card temperature above nominal
0079 None Card temperature within nominal levels
0082 Major Alarm in Fuse Panel
0083 None Fuse Panel alarm has cleared
0097 None IMT allowed
0098 None IMT inhibited
0106 None IMT Bus alarm cleared
0107 Minor Minor IMT failure detected
0108 Major Major IMT failure detected
0109 None All IMT System level alarms cleared
0110 Minor Failure detected on one IMT bus
0111 Major Failure on both IMT A and IMT B
0112 Critical Major failures detected on both IMTs
0120 Critical ENUM SYSTEM is not available
0121 None ENUM SYSTEM is available
0122 Major ENUM SYSTEM normal, card(s) abnormal
0123 None ENUM SYSTEM is removed
0142 None System release alarm cleared
0143 Minor System release GPL(s) not approved
0144 Minor System release version unknown
0276 Major Insufficient memory for IP7 provisioning
0277 Major AS Unavailable
0278 None AS Available
System Maintenance Unsolicited Output Message Groups
B-32 EAGLE Unsolicited Alarm and Information Messages Reference
Table B-15 (Cont.) System Maintenance Unsolicited Output Message Groups
UAM/UIMNumber
Alarm Level Message Text
0279 Minor AS Restricted
0280 None AS Unrestricted
0294 None REPT-ALMINH: alarm output PERM inhibit
0295 None REPT-ALMINH: alarm output enabled
0296 None REPT-ALMINH: alarm output TEMP inhibit
0302 Minor Cooling fan failure
0303 None Cooling fan normal
0308 Critical Node isolated due to SLK failures
0309 None Node is no longer isolated
0366 None Temp Key(s) expiration alarm cleared
0367 Major Temp Keys(s) expiring soon
0368 Critical Temp Keys(s) have expired
0388 None Illegal Address Error Cleared
0389 None Card responding normally
0390 Major Illegal Address Error
0391 Major Card not responding Error
0392 Major OA&M IP Security feature is OFF
0393 None OA&M IP Security feature is ON
0438 Critical Degraded Mode, Invalid OAM HW config
0439 None Exiting Degraded Mode
0466 Major STC Network Unavailable
0467 None STC Network Available
0483 Critical DEIR System is not available
0484 Major DEIR System normal, card(s) abnormal
0485 None DIER System is available
0496 None DEIR System is removed
0500 None Alarm for this entitiy is being cleared
0514 Major Standby MASP is inhibited
0515 None Standby MASP is allowed
System Maintenance Unsolicited Output Message Groups
Unsolicited Output Message Groups B-33
Table B-15 (Cont.) System Maintenance Unsolicited Output Message Groups
UAM/UIMNumber
Alarm Level Message Text
0520 Critical Frame power usage reached LVL3
0521 Major Frame power usage reached LVL2
0522 Minor Frame power usage reached LVL1
0523 None Frame power usage normal
0524 None REPT-ALMINH: alarm output TIMED inhibit
0525 None Timed alm inh rdy to expire
0561 Critical Can't establish Hi Bit rate;All HW OK
0562 None High Bit rate established
0563 Major IMT Bit rate mismatch detected
0564 None IMT Bit rate mismatch cleared
0592 Critical <subsystem> Subsystem is not available
0593 Critical <subsystem> Subsystem is disabled
0594 Minor <subsystem> Subsystem normal, card(s) abnormal
0595 None <subsystem> Subsystem is available
0596 None <subsystem> Subsystem is removed
0619 Critical SIP SYSTEM is not available
0620 None SIP SYSTEM is available
0627 Critical SFLOG SYSTEM is not available
0628 None SFLOG SYSTEM is available
0629 None SFLOG SYSTEM is removed
0911 Major Dynamic database is inconsistent
0912 None Dynamic database is now consistent
1000 None MTP rcvd UPU - user part is not SCCP
1001 None MTP rcvd Transfer Controlled (TFC)
1002 None MTP rcvd invalid TFC - status 0
1003 None MTP rcvd invalid H0/H1 code
1004 None MTP rcvd unknown DPC
1059 None Telnet terminal connection disconnected
1098 None Unexpected disk access timeout
System Maintenance Unsolicited Output Message Groups
B-34 EAGLE Unsolicited Alarm and Information Messages Reference
Table B-15 (Cont.) System Maintenance Unsolicited Output Message Groups
UAM/UIMNumber
Alarm Level Message Text
1101 None SDRAM single bit error report
1105 None REPTEVT:IMTGPL reloading
1106 None REPTCOND:IMTGPL reloading
1118 None TOD change affects MEAS collection
1120 None TRBL Queue is full: elements overwritten
1129 None Ported subs SMSC matches Home SMSC Addr
1130 None LOCREQ rcvd - IS412GSM not provisioned
1131 None Invalid digits in IS41MAP Digits parm
1156 None Minor congestion event detected
1157 None Major congestion event detected
1187 None GPL Table Checksum Mismatch
1188 None DB Subset Checksum Mismatch
1194 None IP connection Refused, RHOST mismatch
1196 None IP Connection Congestion Timeout
1197 None IP Connection refused
1198 None IP Connection, Cannot resolve RHOST
1200 None INWALT card as first to be preloaded
1201 None INWMAIN card as last to be reset
1202 None INW Asserted DDL inhibition
1203 None INWCard reset command issued
1204 None INW Waiting for card loading validation
1205 None INW Detected card loaded
1206 None INW Detected card reset or removed
1207 None INW Allowed card to skip DDL inhibited
1208 None INW Removed DDL inhibition
1209 None INWCard must be reset/removed/inhibited
1210 None INWCard failed to reset
1211 None INW Failed to assert DDL inhibition
1212 None INW Failed to remove DDL inhibition
System Maintenance Unsolicited Output Message Groups
Unsolicited Output Message Groups B-35
Table B-15 (Cont.) System Maintenance Unsolicited Output Message Groups
UAM/UIMNumber
Alarm Level Message Text
1213 None INWCard failed to DDL crossload
1214 None INW Allowed card to DDL crossload
1235 None Unable to connect Primary SFLOG Server
1236 None Unable to connect both SFLOG Servers
1237 None Dynamic database audit not current
1239 None Ntwrk Card Reload Failed during Upg
1308 None Updates inhibited: Target-Cell CRC Fail
1309 None Updates inhibited: Source-Cell CRC Fail
1320 None FPT value unprovisioned for frame
1321 None EAGLE RTDB Birthdate Mismatch
1322 None EAGLE RTDB Levels Invalid
1323 None EAGLE/ELAP TN Quantity Mismatch
1324 None EAGLE/ELAP NPANXX Quantity Mismatch
1325 None EAGLE/ELAP LNRN Quantity Mismatch
1326 None EAGLE RTDB Depth Alert
1330 None Mismatched UA Routing Context
1331 None IPRoute Table Entry Conflict
1333 None UA RCVD MSG DISCARDED
1334 None UA TX MSG DISCARDED
1335 None Table Information
1336 None UA ERROR MSG RECEIVED
1337 None UA HEARTBEAT TIMEOUT
1338 None SCCP did not route - no PC in CgPA
1339 None SCCP did not route - no dflt Clg PC Set
1340 None REPTCOND: TRBL resynch required
1349 None MSU invalid size – discarded
1356 None EXT BERT terminated with OAM switchover
1369 None ISUP IAM decode failed
1370 None ISUP IAM Cld Pty decode failed
System Maintenance Unsolicited Output Message Groups
B-36 EAGLE Unsolicited Alarm and Information Messages Reference
Table B-15 (Cont.) System Maintenance Unsolicited Output Message Groups
UAM/UIMNumber
Alarm Level Message Text
1371 None ISUP encode Failed
1377 None SSH session disconnected - server busyl
1424 None IMT A [B] requested to re-align at LOW [HIGH] Rate
1437 None IMT [A|B]: Rate change not initiated
1490 None Telnet terminal connection successful
1491 None Terminal enabled
1492 None Terminal disabled
1170 None OAMHC Meas transition complete
1171 None Schd UI Rpt disbld-link cnt exceeds 700
UIM Redirect Unsolicited Output Message Group
Table B-16 UIM Redirect Unsolicited Output Message Group
UAM/UIMNumber
Alarm Level Message Text
1043 None SCCP did not route - bad translation
1046 None SCCP did not route - DPC not in MAP tbl
The UIM Redirect output message group is used only if the UIMRD field in rtrv-stpopts is setto yes. Otherwise, this message is output in the GTT Unsolicited Output Message Group (see GTT Unsolicited Output Message Group).
UIM Redirect Unsolicited Output Message Group
Unsolicited Output Message Groups B-37
UIM Redirect Unsolicited Output Message Group
B-38 Unsolicited Alarm and Information Messages Reference
CAuto-Inhibit Hardware Verification Codes
This appendix provides a list of the auto-inhibit hardware verification codes used inthe card device format.
Hardware Verification Codes in UAMsThe following table contains a list of the hardware verification codes that appear incertain UAMs, and shows the card or application that it applies to, a description of thecode, and the UAM code with which it is associated.
Table C-1 Auto-Inhibit Hardware Verification Codes
HW VerificationCode
Card orApplicationCode
Description Associated UAMCode
058 SS7IPGW,IPGWI, IPLIM,IPLIMI
E5-ENET or E5-ENET-Bdoes not support > 16associations (IPLIMx).
E5-ENET or E5-ENET-Bdoes not support > 50associations (IPGWx).
422
059 VSCCP MPS database has beendetected to exceed capacityof Service Module extendedmemory (only for GPORT,GFLEX, INP, EIR features).UAMs 281, 283, and 285 areused for LNP and LNPELAP Configurationfeatures.
422
090 Various Flash image on the card isincompatible with thecurrent release of theEAGLE
570
099 E5-TSM E5-TSM card equipped hasone or more daughterboard.
99
101 SS7IPGW,IPGWI, IPLIM,IPLIMI
E5-ENET only supportsSLK link A-7 and B-7.
276
Auto-Inhibit Hardware Verification Codes C-1
Table C-1 (Cont.) Auto-Inhibit Hardware Verification Codes
HW VerificationCode
Card orApplicationCode
Description Associated UAMCode
102* SS7IPGW,IPGWI
Non-DCM detected in slot. 99
103 SS7IPGW,IPGWI, IPLIM,IPLIMI
E5-ENET or E5-ENET-Bdoes not support >16associations (IPLIMx).
E5-ENET or E5-ENET-Bdoes not support >50associations (IPGWx).
276
104 SS7IPGW,IPGWI, IPLIM,IPLIMI
E5-ENET or E5-ENET-Bdoes not support >0 sockets(IPLIMx).
E5-ENET or E5-ENET-Bdoes not support >0 sockets(IPGWx).
276
105 SS7IPGW,IPGWI, IPLIM,IPLIMI
E5-ENET or E5-ENET-Bdoes not support > 0(sockets + associations)(IPLIMx).
E5-ENET or E5-ENET-Bdoes not support > 50(sockets + associations)(IPGWx).
276
106 SS7IPGW,IPGWI, IPLIM,IPLIMI
E5-ENET or E5-ENET-Bdoes not support >3200KbSCTP buffers (IPLIMx).
E5-ENET or E5-ENET-Bdoes not support >3200KbSCTP buffers (IPGWx).
276
124 HC-MIM Card is not an HC-MIM andis provisioned as a T1 card.
99
129 HC-MIM, E5-E1T1
Card does not support CASframing.
297
132 IPLIM, IPLIMI,HC-MIM, E5-E1T1
The actual card in the slotmust be a HC-MIM, highcapacity MIM or LIME1 ifcard is provisioned as aLIME1 card.
99
Hardware Verification Codes in UAMs
C-2 EAGLE Unsolicited Alarm and Information Messages Reference
Table C-1 (Cont.) Auto-Inhibit Hardware Verification Codes
HW VerificationCode
Card orApplicationCode
Description Associated UAMCode
133 HC-MIM, E5-E1T1
The actual card in the slotmust be a high capacityMIM card (either HC-MIMor E5-E1T1) if provisionedwith any un-channelized T1ports.
99
134 E5-E1T1 E5-E1T1 card with SLKprovisioned on link greaterthan 15.
99
135 E5-E1T1 E5-E1T1 card supports only1 SE-HSL link.
276
136 E5-ATM, E5-ATM-B
E5-ATM card port B isprovisioned
297
140 MCPHC MCP card not running withD2G memory
422
141 IPS E5-IPSM card not runningwith D2G memory.
422
142 MCP E5-MCPM-B card notrunning with D4G memory.
422
150 various Card is obsolete. 47
165 VSCCP Hardware configurationdoes not supportconfigured feature set.
99
170 EROUTE Non-E5-ENET/E5-ENET-Bcard detected in slotprovisioned for eroute withcard type STC.
99
171 STPLAN Non-E5-ENET/E5-ENET-Bcard detected in slotprovisioned for STPLANwith card type DCM.
99
Hardware Verification Codes in UAMs
Auto-Inhibit Hardware Verification Codes C-3
Table C-1 (Cont.) Auto-Inhibit Hardware Verification Codes
HW VerificationCode
Card orApplicationCode
Description Associated UAMCode
172 E5-ENET-B cardwith IPSG
An EPM-A based card hasbeen detected ina lotprovisioned for EPM-Bbased card, so the card willbe auto-inhibited and issuea degraded mode alarm.
To permit an E5-ENET to beallowed in a card slotprovisioned for E5-ENET-Band to clear the alarm, achg-card command will berequired to change the cardtype from enetb to enet, orthe E5-ENET card will needto be removed from the slot.
Non-SLIC card detected inslot provisioned for IPSGand card type is SLIC withdata=gtt.
99
174 IPSG SLIC hardware detectedhaving 32-bit flash GPL(BLSLC32) in a slotprovisioned for IPSG andcard type is SLIC withdata=gtt.
99
Hardware Verification Codes in UAMs
C-4 EAGLE Unsolicited Alarm and Information Messages Reference
Table C-1 (Cont.) Auto-Inhibit Hardware Verification Codes
HW VerificationCode
Card orApplicationCode
Description Associated UAMCode
179 E5-ATM-B, E5-ENET-B, E5-E1T1-B
EPM-B based card detectedand MFC is OFF.
MFC option needs to be setto ON in STPOPTS beforeallowing the EPM-B basedcard. Note that theON/OFF format is beingused.
For example, at least oneMFC option needs to be setto ON in STPOPTS beforeallowing an E5-ENET-Bcard. The various optionvalues that support MFCare STPOPTS:ON={mtplti,mtprsi, mtplprst, uimrd,critalminh, dispactalms,rptlnpmrss, rstrdev,cnvcgda, cnvcgdi, cnvcgdn,cnvcgdn24, gtcnvdflt,ansigflex, archbldid, mfc,cnvcgdn16}.
Note: This code is specificto cards that do not supportTVG.
99
180 SCCP, SS7ANSI
DEIR, ENUM,SIP
SCCP card equipped withDCM with MOBR on.
If ports C and D areconfigured, the cardlocation must be populatedwith SLIC cards only.
441
441
Hardware Verification Codes in UAMs
Auto-Inhibit Hardware Verification Codes C-5
Table C-1 (Cont.) Auto-Inhibit Hardware Verification Codes
HW VerificationCode
Card orApplicationCode
Description Associated UAMCode
180 IPLIM, SCCP,SS7ANSI
IPLIM card equipped withdouble slot DCM withMOBR on
-or-
SCCP card equipped withTSM with MOBR on
-or-
SS7ANSI card equippedwith one of the followingwith MOBR on: LIMDS0 /LIMV35 / LIMOCU / LIM-AINF / ILA / EILA /LIME1
441
Hardware Verification Codes in UAMs
C-6 EAGLE Unsolicited Alarm and Information Messages Reference
Index
C
Corrective Maintenance, 1-2
I
Invalid digits in IS41 MAP Digits parm, B-35
P
Preventive Maintenance, 1-2
Index-1