Connect the System Charger Set to the H200 Wireless Orthosis and the H200 Wireless Control Unit simultaneously. Charge the H200 Wireless System daily. Charging the H200 Wireless System Bioness Inc. 25103 Rye Canyon Loop Valencia, CA 91355 Telephone: 800.211.9136 or 661.211.9136 Email: [email protected] Website: www.bioness.com User's Reference Card H200 Wireless Orthosis Displays System On Status Light Flashes Green Stimulation On Stim Light Flashes Yellow Stimulation Paused Stim Light Steady Yellow Faulty Electrode Contact Status Light Flashes Red Hardware/Software Error; Charging Error Status Light Steady Red_ 612-00976-001 Rev. A 02/2018 Bioness Europe B.V. Stationsweg 41 3331 LR Zwijndrecht, The Netherlands Telephone: +31.78.625.6088 Website: www.bioness.com Putting on the H200 Wireless Orthosis 3 4 5 6 2 1 4 5 6 3 Wet and attach the cloth electrodes. Position the Orthosis on a stable surface, and put your hand into the spiral end. The Thenar (with attached electrode) should rest at the base of your thumb. Position the wrist bridge comfortably on the back of your wrist. Place your forearm in the Orthosis flexor support. Close the extensor wing. Fasten the wrist strap, if appropriate. 2 1 Control Unit Charging Displays Flashes Yellow Low Battery Rotating Green Circle Charging Horizontal Green Line Fully Charged Orthosis Charging Displays Status Light Flashes Yellow Low Battery Status Light Flashes Yellow and Green Charging Status Light Steady Green Fully Charged H200 Wireless Orthosis H200 Wireless Control Unit System Charger Set See User’s Guide

Upload: others

Post on 12-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: User's Reference Card · Low Battery Status Light Flashes Yellow and Green Charging Status Light Steady Green Fully Charged H200 Wireless Orthosis H200 Wireless Control Unit System

Connect the System Charger Set to the H200 Wireless Orthosis and the H200 Wireless Control Unit simultaneously. Charge the H200 Wireless System daily.

Charging the H200 Wireless System

Bioness Inc.25103 Rye Canyon LoopValencia, CA 91355Telephone: 800.211.9136 or 661.211.9136Email: [email protected]: www.bioness.com

User's Reference Card

H200 Wireless Orthosis Displays

System OnStatus Light

Flashes Green

Stimulation OnStim Light

Flashes Yellow

Stimulation PausedStim Light

Steady Yellow

Faulty ElectrodeContact

Status Light Flashes Red

Hardware/SoftwareError; Charging ErrorStatus Light Steady Red_

612-

0097

6-00

1 R

ev. A

02

/201

8

Bioness Europe B.V. Stationsweg 413331 LR Zwijndrecht, The NetherlandsTelephone: +31.78.625.6088 Website: www.bioness.com

Putting on the H200 Wireless Orthosis

3 4 5 621

4

5

6

3

Wet and attach the cloth electrodes.Position the Orthosis on a stable surface, and put your hand into the spiral end. The Thenar (with attached electrode) should rest at the base of your thumb.Position the wrist bridge comfortably on the back of your wrist.Place your forearm in the Orthosis flexor support.Close the extensor wing.Fasten the wrist strap, if appropriate.

2

1

Control Unit Charging Displays

Flashes Yellow Low Battery

Rotating Green Circle Charging

Horizontal Green Line Fully Charged

Orthosis Charging Displays

Status Light Flashes Yellow Low Battery

Status Light Flashes Yellow and Green Charging

Status Light Steady Green Fully Charged

H200 Wireless Orthosis

H200 Wireless Control Unit

System Charger Set

See User’s Guide

Page 2: User's Reference Card · Low Battery Status Light Flashes Yellow and Green Charging Status Light Steady Green Fully Charged H200 Wireless Orthosis H200 Wireless Control Unit System

H200 Wireless Control Unit Displays

On/Off Button Flashes Green System is On

Trigger Button Flashes Yellow Rapidly Stimulation is On

Trigger Button is a Steady Yellow Stimulation is Paused

Program 1 Indicator is Green Program 1 Selected

Program 2 Indicator is Green Program 2 Selected

Control Unit Status Indicator is a Steady RedControl Unit Malfunction: Charging Error; Registration Error; Software Error

RF Communication Indicator Flashes Red RF Communication Error

Operating the H200 Wireless System

1 Turn on the system. Press the on/off button. Test the position of the Orthosis. Press and hold the stimulation test button once to test the extensor muscles. Release the button and press and hold again to test the flexor muscles. Repeat as needed. Select Program 1 or Program 2. Press the Program 1 or Program 2 selection button on the side of the Control Unit. The selected program indicator will be GREEN: or .If necessary, adjust the stimulation intensity level. Press the plus or minus button to increase/decrease stimulation intensity in the Orthosis.Start a program. Press the trigger button on the Control Unit or the trigger button on the Orthosis to turn on stimulation. To pause/resume a program, press the trigger button on the Control Unit or the trigger button on the Orthosis. Note: Neuroprosthesis Programs cannot be paused. Pressing the trigger button when stimulation is on initiates the next phase of the program. To turn off stimulation, press the

on/off button.

2

3

4

5

H200® Wireless, Bioness, the Bioness Logo® and LiveOn® are trademarks of Bioness Inc. in the United States or other countries. | www.bioness.com

15

4

On/Off Button Trigger Button

Intensity Adjustment Buttons

Program 2 Indicator

Program 1 Indicator RF Communication Indicator

Control Unit Status Indicator

Program 1 Selection ButtonProgram 2 Selection Button

Mute Button

Stimulation Test Button

3

2Intensity Level

For a complete list of all contraindications, warnings, adverse reactions, precautions, and care instructions please review the User’s Guide found at www.bioness.com.

Rx Only (US Only)

©2018