Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T. Cease Cease Industrial Consulting Charleston, SC [email protected] [email protected]

Upload: phamtruc

Post on 31-Jan-2018

223 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

Using Vibration Analysis To

Identify & Help Correct An ID Fan

Foundation Problem

Barry T. Cease

Cease Industrial Consulting

Charleston, SC

[email protected]

[email protected]

Page 2: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

MACHINE & PROBLEM DESCRIPTION

• Large induced draft fan, directly driven by a VFD controlled induction motor.

• Normal operating speeds were from 500 – 900 rpm with most typical being 600 – 800 rpm.

• Job began with a call to balance this fan.

• Others had tried unsuccessfully to balance it in the past.

• Plant had run the motor solo prior to my arrival and solo motor levels were significantly lower leading us to believe the problem wasn’t the motor.

2 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 3: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

PHOTO OF FAN FROM REAR

3 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 4: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

ON-SITE INSPECTION & INITIAL DATA, p1

• Prior to any vibration measurements, on-site inspection of the

B fan during operation noted significant movement/vibration at

the fan & motor bearings but also at the concrete foundation

surrounding the entire machine.

• The plant had two seemingly identical ID Fans (A & B)

operating about 100 ft from one another. Only the “B” fan had

a vibration problem.

• Vibration data was collected using both seismic & proximity

probes that were permanently mounted at the bearings.

• Only the seismic data showed a significant vibration problem.

Vibration levels at the proximity probes were not excessive.

4 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 5: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

ON-SITE INSPECTION & INITIAL DATA, p2

• Vibration spectral data showed dominant vibration occurring

at 1x rpm with no significant vibration occurring at any other

frequency.

• Coast-down data showed 1x rpm levels increasing

significantly with increasing speed.

• 1x Peak/Phase data showed high in-phase vibration in the

horizontal direction at both motor & fan.

• Vibration levels in the horizontal direction across the entire

machine were much higher than either the vertical & axial

directions (see profile plots).

5 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 6: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

INITIAL OA VIBRATION PROFILES - A & B ID FANS

6 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 7: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

INITIAL 1X RPM VIBRATION PROFILES - A & B ID FANS

7 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 8: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

INITIAL WAVEFORM DATA - A & B ID FANS

8 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 9: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

INITIAL SPECTRAL DATA – A & B ID FANS

9 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 10: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

0

30

60

90

120

150

180

210

240

270

300

330

360

0.00

2.00

4.00

6.00

8.00

10.00

12.00

600 650 700 750 800 850 900 950

PH

AS

E A

NG

LE

ID

EG

)

1X

RP

M V

IBR

AT

ION

(M

ILL

S-P

K-P

K)

FAN SPEED (RPM)

COASTDOWN DATA BEFORE BALANCING - B ID FAN

FIH-PK FOH-PK Unbalance FIH-PH FOH-PH

Note the departure from

expected unbalance

curve past ~ 800 rpm

“Region of change”

Notable change in slope

of coast-down curve

> 800 rpm

No significant

change in phase

curve until higher

speed > 825 rpm

COASTDOWN DATA, BEFORE BALANCING – B ID FAN

10 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 11: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

INITIAL BALANCE PLAN

• Due to production concerns, balancing of the fan took place weeks later at a time better suited for the plant (lower demand).

• Due to the non-linear nature of the coast-down data collected, a two-step balancing process was decided upon as follows:

1) Initial balancing would be performed at the slower speed of 675 rpm.

2) Final (trim) balancing would be performed as needed at a higher speed (800 to 900 rpm).

• By first balancing the fan at a lower speed, we would lower the dynamic forces present at higher speeds and hopefully avoid the non-linear aspects of the system.

11 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 12: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

1ST BALANCE DATA,

675 RPM (DEC 2010)

BALANCE CALCULATIONS, SINGLE-PLANE 2013

Magnitude Angle (deg)

Reference/Original Vector (O): 3.33 130.5

Trial Weight (TW): 64 240

Original + Trial Vector (O+T): 1.39 64

Trial Vector (T): 3.05 24.7

Alpha (angle between O & T): 25

Correction Weight (+Alpha): 69.8 265

Correction Weight (-Alpha): 69.8 215

Balance Sensitivity (TW/T): 21.0

Phase Lag (+Alpha): 134

Phase Lag (-Alpha): 85

12/13/2010 675 RPM - MILLS

0

0.5

1

1.5

2

2.5

3

-3 -2 -1 0 1

O+T

O

T

CW = TW * O / T

θ CW = θ TW + α

SENSITIVITY = TW / T or CW / T

PHASE LAG = θ CW - θ O

Original or Reference

Vector (O)

Original plus Trial

Vector (O+T)

Trial Vector (T)

α

12 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 13: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

COASTDOWN DATA, BEFORE & AFTER 1ST BALANCING

13 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 14: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

INITIAL BALANCE RESULTS & CONCLUSIONS

• Balancing of fan reduced 1x rpm vibration levels by 80 to 85% with final levels at or very near 1 mills-pk-pk.

• Fan was run thru its normal operating speed range after the initial balance @ 675 rpm and even at 900 rpm, its levels were acceptable so no trim balance was necessary.

• Conclusions from the balance report listed concerns as to the integrity of the foundation due to the following:

1) Significant vibration felt in the surrounding area (pedestals, foundation & ground) around the fan prior to balancing.

2) Much higher horizontal versus vertical or axial levels across entire machine.

3) Extreme difficulty experienced by others who previously attempted to balance this fan.

• Recommendation was made to have the foundation evaluated by a civil engineering firm and follow their recommendations towards improving its stiffness & integrity.

14 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 15: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

DECISION MADE TO EVALUATE &

IMPROVE FOUNDATION, p1

• Fan was balanced six times over two years due to high 1x rpm

vibration.

• Each time balancing successfully reduced vibration @ 1x rpm,

but it didn’t take long until high vibration returned (3 to 6

months) and balancing was needed again.

• During this time no significant problems were noted from the

A ID Fan nearby which experienced the same operating

conditions.

15 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 16: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

DECISION MADE TO EVALUATE &

IMPROVE FOUNDATION, p2

• The decision was made to evaluate & correct as necessary the

potential foundation problem.

• The civil engineering firm that originally installed the fan was

contracted to perform the evaluation.

• Cease Industrial Consulting was contracted to assist the civil

engineering firm as needed in pinpointing problems with the

foundation.

16 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 17: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

TEST SETUP – ODS ANALYSIS OF FAN

• After consultation with a structural engineer at the civil engineering firm, a test setup for an in-depth ODS analysis of the fan foundation was decided upon as follows:

1) Prior to the ODS analysis, the fan would be balanced to a very low level of unbalance (< 1 mill vibration).

2) A known amount of unbalance (50 oz @ 56” radius 2,800 oz-in of unbalance) would then be intentionally placed at a known location on the fan wheel to provide a known,dominant dynamic force within the system.

3) The fan would then be run at a constant speed of 900 rpm and ODS measurements would be collected on the fan & motor bearings, bases, pedestals & all over the surrounding foundation to provide a good “picture” for how the entire machine/foundation system vibrated when subjected to a known dynamic force.

4) Because we knew the exact amount of applied force (4,000 lbs @ 900 rpm) and exactly where it was applied (thru the fan bearings), the measured vibration levels (deflections) at each point could be used as experimental data to aid the accuracy of an FEA analysis of the fan/foundation system.

17 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 18: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

FOH (50Y) @ 5.1 MILLS

FOV (50Z) @ 1.5 MILLS

FIV (1Z) @ 1.5 MILLS

FIH (1Y) @ 4.0 MILLS

INBOARD

CONCRETE

PEDESTAL

OUTBOARD

CONCRETE

PEDESTAL

FOUNDATION

MOTOR

ODS Model of B ID Fan. Vibration levels are at 1x rpm (~ 900 rpm). Condition is with ~ 50 oz weight attached to fan wheel

at ~ 56” radius (2,800 oz-in of unbalance) applying an estimated centrifugal force of 4,000 lbs on the machine in the radial

directions. Note how vertical foundation levels are similar to vertical measurements at fan bearings.

MOH (3Y) @ 3.2 MILLS

FOUNDATION

(164Z) @ 1.5

MILLS

FOUNDATION

(103Z) @ 1.3

MILLS

18 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 19: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

FOUNDATION IMPROVEMENTS

• An FEA analysis of the fan/motor/foundation system was performed

with the ODS test data being used to refine the FEA model.

• The foundation was improved by adding 6-ea new piles on either

side of both the inboard & outboard concrete pedestals (see figure

below).

• Large masses composed of a rebar/concrete matrix were added &

attached to the new piles. These new masses were also attached to

the existing pedestals.

• The table below shows data pertaining to both the old & new

foundation designs:

19 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 20: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

COMPARE OLD & NEW

FOUNDATIONS

Weight (lbs/tons) Foundation/Rotor Ratio

Fan Rotor Weight 34,000/17

Old Foundation Design 99,000/50 2.85:1

New Foundation Design 156,000/78 4.5:1

Industry Recommendations ≥ 4:1

20 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 21: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

Added

piles &

mass

(inboard)

Inboard

Pedestal

Outboard

Pedestal Top View

Side View of inboard

piles & mass

Added

piles &

mass

(outboard)

X’s show pile

locations

Side View of outboard

piles & mass

Rebar

matrix &

connection

to existing

pedestal

21 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 22: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

FAN BALANCE SENSITIVITY CALCULATIONS:

BEFORE & AFTER FOUNDATION MODIFICATIONS

BALANCE DATE FAN BALANCE SPEED

(RPM)

BALANCE

SENSITIVITY

(OZ/MILLS-PK-PK)

12/13/10 – “B” ID FAN 675 21

5/18/11 – “B” ID FAN 800 17

8/18/11 – “B” ID FAN 800 21

5/18/12 – “B” ID FAN 750 19

5/18/12 – “B” ID FAN 885 11

8/5/12 – “B” ID FAN 900 10

11/2/12 – “A” ID FAN 894 31

11/6/12 – “B” ID FAN 900 36

After Foundation

Modifications

Before Foundation

Modifications

A Fan measurement

(sister machine)

22 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 23: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

WHY DID THIS MODIFICATION WORK?

• From Newton’s 2nd Law Of Motion: F = m * a or when we rearrange the equation we get the following: a = F/m

• Thus, when we increase the mass (m), in general, we will lower the acceleration levels (a).

• Also, from Hooke’s Law: F = k * x and rearranging this equation we get the following: x = F/k

• Thus, when we increase the stiffness (k), in general, we will lower the displacement levels (x).

• By upgrading the foundation we may very well have moved a potential fan natural frequency higher (> 900 rpm) thus reducing or eliminating its amplification of our vibration levels.

23 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 24: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

PHOTO OF FAN PRIOR TO FOUNDATION

MODIFICATIONS

24 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 25: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

PHOTO OF FAN AFTER FOUNDATION

MODIFICATIONS

Additional mass & piles added to

either side of both inboard &

outboard concrete pedestals

25 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem

Page 26: Using Vibration Analysis To Identify & Help In Correcting ... Fan Foundation 1214.pdf · Using Vibration Analysis To Identify & Help Correct An ID Fan Foundation Problem Barry T

SUMMARY

• Vibration analysis was used successfully to identify a

weak foundation for a large ID fan.

• ODS analysis was used both as a visual aid to the

foundation problem and to help refine an FEA model

of the fan/foundation system.

• The effectiveness of the redesigned foundation has

been proved by much higher balance sensitivity

measurements on the fan at identical speeds and by

the fact that the fan has run for well over a year now

with no balance problems.

26 Cease Industrial Consulting - Correcting An ID Fan Foundation Problem