venmar avs wall controls - icf-and-more-ok.com... 90310 residential products group, 550 lemire...

5
WALL CONTROLS All Venmar AVS wall controls are user-friendly. ey were created for people who want to maximise the benefits of their residential ventilation unit. With Venmar AVS wall controls, the homeowner’s specific needs are fulfilled. MAIN CONTROLS VC0101 SMART SET MODE PREF Operation Modes SMART Mode Our latest innovation! This mode optimizes automatically the ventilation functions to ensure reaching an unsurpassed comfort in the house. VENT Mode In this mode, the air exchange with the outside is performed with the speed (OFF, MIN or MAX) or with a 20, 30 or 40-minute per hour cycle, according to the user’s choice. RECIRC Mode In this mode, the user decides to recirculate the air inside his house (OFF, MIN, MAX or OFF, MAX, according to the unit). PROG Mode The ventilation unit operation is factory set for alls 4 periods (morning, day, evening and night), for week days and week end days. However, these settings can be modified by the user to meet his own needs. ALTITUDE Part no. 40445 Automatic and programmable control (keeps in memory all ventilation settings even aſter a power failure) Digital display with backlight (blue or green) Day, hour and periods of the day displayed • Dynamic exchange and recirculation indicators, and also indoor and outdoors temperature Maintenance indicator VC0119 DECO-TOUCH Part no. 40400 Allows the user to choose either the manual modes or the automatic mode (dehumidistat) 1” x 1” LCD display Digital display with blue backlighting Dynamic exchange and recirculation* indicators Interior relative humidity displayed Maintenance indicator Operation Modes RECIRC Mode* In this mode, the air is recirculated inside the house at high speed. 20 min/h Mode The ventilation unit exchanges air intermittently on a one-hour cycle as follows: OFF for 40 min. (or recirculation* on high or low speed for 40 min.) and then exchanges air during 20 min. on low speed. Repeats cycle after the 20 min. of air exchange. Min Mode Air is exchanged with the outside on low speed. Max Mode Air is exchanged with the outside on high speed. Hygrometer In the operating modes listed above, select a dehumidistat override so that if the relative humidity (RH) in the house exceeds the RH setting previously stored, the ventilation unit will exchange in high speed until the target indoor RH setting is reached. * Recirculation is not available to alll units. For more details, please refer to the compatibility chart on last pages. Due to the constant evolution of our technologies, it may be possible that some control functions are not compatible to some earlier unit models. For more details, please refer to the compatibility chart on last pages.

Upload: others

Post on 17-Jun-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Venmar AVS Wall Controls - icf-and-more-ok.com... 90310 Residential Products Group, 550 Lemire Blvd., Drummondville, Qc, Canada J2C 7W9 - Tel.: 1-800-567-3855 Fax: 1-800-567-1715 Model

WALL CONTROLS

All Venmar AVS wall controls are user-friendly. Th ey were created for people who want to maximise the benefi ts of their residential ventilation unit. With Venmar AVS wall controls, the homeowner’s specifi c needs are fulfi lled.

MAIN CONTROLS

VC0101

SMARTSETMODEPREF

Operation ModesSMART Mode

Our latest innovation! This mode optimizes automatically the ventilation functions to ensure reaching an unsurpassed comfort in the house.

VENT ModeIn this mode, the air exchange with the outside is performed with the speed (OFF, MIN or MAX) or with a 20, 30 or 40-minute per hour cycle, according to the user’s choice.

RECIRC ModeIn this mode, the user decides to recirculate the air inside his house (OFF, MIN, MAX or OFF, MAX, according to the unit).

PROG ModeThe ventilation unit operation is factory set for alls 4 periods (morning, day, evening and night), for week days and week end days. However, these settings can be modified by the user to meet his own needs.

ALTITUDEPart no. 40445

• Automatic and programmable control (keeps in memoryall ventilation settings even aft er a power failure)

• Digital display with backlight (blue or green)• Day, hour and periods of the day displayed• Dynamic exchange and recirculation indicators, and also indoor and

outdoors temperature• Maintenance indicator

VC0119

DECO-TOUCHPart no. 40400

• Allows the user to choose either the manual modes orthe automatic mode (dehumidistat)

• 1” x 1” LCD display• Digital display with blue backlighting• Dynamic exchange and recirculation* indicators• Interior relative humidity displayed• Maintenance indicator

Operation ModesRECIRC Mode*In this mode, the air is recirculated inside the house at high speed.

20 min/h ModeThe ventilation unit exchanges air intermittently on a one-hour cycle as follows: OFF for 40 min. (or recirculation* on high or low speed for 40 min.) and then exchanges air during 20 min. on low speed. Repeats cycle after the 20 min. of air exchange.

Min Mode

Air is exchanged with the outside on low speed.

Max Mode

Air is exchanged with the outside on high speed.

HygrometerIn the operating modes listed above, select a dehumidistat override so that if the relative humidity (RH) in the house exceeds the RH setting previously stored, the ventilation unit will exchange in high speed until the target indoor RH setting is reached.

* Recirculation is not available to alll units. For more details, please refer to the compatibility chart on last pages.

Due to the constant evolution of our technologies, it may be possible that some control functions are not compatible to some earlier unit models. For more details, please refer to the compatibility chart on last pages.

Page 2: Venmar AVS Wall Controls - icf-and-more-ok.com... 90310 Residential Products Group, 550 Lemire Blvd., Drummondville, Qc, Canada J2C 7W9 - Tel.: 1-800-567-3855 Fax: 1-800-567-1715 Model

MAIN CONTROLS (CONT’D)

- -5°C23°F

5°C41°F

C OM

FOR

TZ

ON

E

-20°C-4°F

OFF MIN MAX

#XXX

XX

01/98

VC0086

CONSTRUCTO

ConstructoPart no. 40350

Th e Constructo main control adjusts the air supply speed using the sliding button: OFF, MIN (low speed air exchange) and MAX (high speed air exchange). Also, the maximum humidity level for your house is selected by the knob.

INTERMITTENT

MAXMIN

VC0124

L-T

Lite-Touch ConstructoPart no. 40370

Th e light indicator of this wall control shows clearly in wich operating mode the unit is.Th is push-button control has three functions:• Intermittent (unit is OFF during 40 minutes and then perform low

speed air exchange with the outdoors during 20 minutes)• Min (low speed air exchange)• Max (high speed air exchange)NOTE: Wall control appearance may slightly vary.

RECIRCULATION

MAXMIN

VC0145

S-T

Simple-Touch ConstructoPart no. 40390

Th e light indicator of this wall control shows clearly in wich operating mode the unit is.Th is push-button control has three functions:• Recirculation (stops exchanging air with the outdoors and recirculates

indoor air at high speed)• Min (low speed air exchange)• Max (high speed air exchange)NOTE: Wall control appearance may slightly vary.

Page 3: Venmar AVS Wall Controls - icf-and-more-ok.com... 90310 Residential Products Group, 550 Lemire Blvd., Drummondville, Qc, Canada J2C 7W9 - Tel.: 1-800-567-3855 Fax: 1-800-567-1715 Model

VC0009

DehumidistatPart no. 11297

Th e knob allows to adjust the maximum desired indoor humidity level during fall, winter and spring. Th is control is graduated in relative humidity percentage degrees. When a higher humidity level is detected, the unit turns on high speed until the situation is corrected.

AUXILIARY CONTROLS

OFF

10

TurnPast

VC0017

20

3040

50

60

MINUTES

HOLD

60-minute mechanical timerPart no. 00910

Th is timer allows for 10 to 60 minutes of high speed operation, to expel rapidly indoor stale air. Can be installed in bathrooms kitchen or laundry room.

VC0141

20-minute lighted push buttonPart no. 12030

Th is timer allows the unit to provide 20 minutes of high speed ventilation at the push of a button, to expel rapidly indoor stale air. Lighted when activated, up to fi ve of them can be installed (e.g.: in bathroom, kitchen, laundry room, etc.).NOTE: Push button appearance may slightly vary.

VC0143

20/40/60 minute push buttonPart no. 03364

Th is timer allows the unit to turn on high speed during 20, 40 or 60 minutes to expel rapidly indoor stale air. Within 2 seconds, press once for 20 minutes, twice for 40 minutes or three times for a 60-minute activation. Press another time to deactivate.NOTE: Push button appearance may slightly vary.

Page 4: Venmar AVS Wall Controls - icf-and-more-ok.com... 90310 Residential Products Group, 550 Lemire Blvd., Drummondville, Qc, Canada J2C 7W9 - Tel.: 1-800-567-3855 Fax: 1-800-567-1715 Model

WA

LL

CO

NT

RO

L C

OM

PAT

IBIL

ITY

CH

AR

T

The

Deh

umid

ista

t, 60

-min

ute

cran

k tim

er a

nd 2

0-m

inut

e pu

sh-b

utto

n tim

er a

re c

ompa

tible

with

all

units

.

Com

patib

le

Not

com

patib

le

Lette

rs a

nd

num

bers

Thi

s co

de is

the

seria

l num

ber

of th

e ve

ntila

tion

unit;

con

side

r on

ly th

e le

tters

and

nu

mbe

rs m

entio

ned,

not

the

“xxx

”. E

. g.:

AV

S E

15 E

CM

ER

V w

ith s

eria

l num

ber

PJ0

5150

0040

07 is

fully

com

patib

le w

ith

Alti

tude

ver

sion

4.0

3 an

d D

eco-

Touc

h ve

rsio

n 2.

04 (

PJ0

515

is h

ighe

r th

an P

J051

4).

NO

TE

1:

Wal

l con

trol

incl

udin

g co

nfig

urab

le lo

w s

peed

rec

ircul

atio

n in

inte

rmitt

ent m

ode.

NO

TE

2:

Low

spe

ed r

ecirc

ulat

ion

in in

term

itten

t mod

e st

arts

with

this

uni

t ser

ial n

umbe

r. H

owev

er, t

his

cont

rol r

emai

ns c

ompa

tible

with

uni

ts w

ith s

eria

l num

ber

unde

r th

is o

ne.

NO

TE

3:

Rec

ircul

atio

n m

ode

is n

ot a

vaila

ble

for

this

uni

t.N

OT

E 4

: T

he c

ompa

tibili

ty s

tart

s fr

om th

at u

nit s

eria

l num

ber.

Sub

ject

to c

hang

e w

ithou

t prio

r no

tice.

Mod

el n

o.N

ame

Alti

tude

ver

sion

3.0

1M

odel

no.

404

40

Alti

tude

ver

sion

4.0

4M

odel

no.

404

45(N

OT

E 1

)

Dec

o-To

uch

vers

ion

2.01

Mod

el n

o. 4

0395

Dec

o-To

uch

vers

ion

2.04

Mod

el n

o. 4

0400

(NO

TE

1)

Lite

-Tou

ch

Con

stru

cto

Sim

ple-

Touc

h C

onst

ruct

oC

onst

ruct

o20

/40/

60

min

utes

4391

1A

VS

E15

EC

M E

RV

PJ0

514x

xxxx

xx (

NO

TE

2)

PJ0

514x

xxxx

xx (

NO

TE

2)

4390

1A

VS

E15

EC

M H

RV

PA04

14xx

xxxx

x (N

OT

E 2

)PA

0414

xxxx

xxx

(NO

TE

2)

4313

5A

VS

E15

HR

VP

C01

14xx

xxxx

x (N

OT

E 2

)P

C01

14xx

xxxx

x (N

OT

E 2

)

4112

6A

VS

E10

HR

VP

E01

14xx

xxxx

x (N

OT

E 2

)P

E01

14xx

xxxx

x (N

OT

E 2

)

4540

0 &

484

001.

8 H

E &

2.6

HE

4670

0 &

477

00D

uo 1

.5 &

Duo

2.0

4612

1 &

471

21N

ovof

it 1.

5ES

& N

ovof

it 2.

0ES

4416

2 &

441

63K

7 E

RV

Qx0

114x

xxxx

xx (

NO

TE

2)

Qx0

114x

xxxx

xx (

NO

TE

2)

4415

2 &

441

53K

8 H

RV

Qx0

114x

xxxx

xx (

NO

TE

2)

Qx0

114x

xxxx

xx (

NO

TE

2)

4450

0 &

445

02K

10 H

RV

Qx0

114x

xxxx

xx (

NO

TE

2)

Qx0

114x

xxxx

xx (

NO

TE

2)

4415

0K

7 H

RV

4612

1 &

160

1702

HR

V C

onst

ruct

o 1.

5ES

NO

TE

3N

OT

E 3

4712

1H

RV

Con

stru

cto

2.0E

SN

OT

E 3

NO

TE

3

4711

5E

RV

Con

stru

cto

2.0E

SN

OT

E 3

NO

TE

3

4672

0 &

467

25S

olo

1.5E

S

4772

0S

olo

2.0E

S

4150

2 &

415

00A

VS

Con

stru

cto

1.0

HR

Vxx

xx08

08xx

xxx

NO

TE

4B

x081

4xxx

xxxx

(N

OT

E 2

)xx

xx08

08xx

xxx

NO

TE

4B

x081

4xxx

xxxx

(N

OT

E 2

)

4150

6 &

415

04A

VS

Con

stru

cto

1.0

ER

Vxx

xx08

08xx

xxx

NO

TE

4B

x081

4xxx

xxxx

(N

OT

E 2

)xx

xx08

08xx

xxx

NO

TE

4B

x081

4xxx

xxxx

(N

OT

E 2

)

4155

4 &

415

56A

VS

C12

ER

V

4155

0 &

415

52A

VS

C12

HR

V

4170

2A

VS

S10

ER

Vpl

us

4170

0A

VS

S10

ER

VN

OT

E 3

NO

TE

3

4170

4A

VS

S10

c E

RV

H50

100H

& H

5010

0EH

5010

0H &

H50

100E

Gx0

314x

xxxx

(N

OT

E 2

)G

x031

4xxx

xx (

NO

TE

2)

Page 5: Venmar AVS Wall Controls - icf-and-more-ok.com... 90310 Residential Products Group, 550 Lemire Blvd., Drummondville, Qc, Canada J2C 7W9 - Tel.: 1-800-567-3855 Fax: 1-800-567-1715 Model

WA

LL

CO

NT

RO

L C

OM

PAT

IBIL

ITY

CH

AR

T

The

Deh

umid

ista

t, 60

-min

ute

cran

k tim

er a

nd 2

0-m

inut

e pu

sh-b

utto

n tim

er a

re c

ompa

tible

with

all

units

.

Com

patib

le

Not

com

patib

le

Lette

rs a

nd

num

bers

Thi

s co

de is

the

seria

l num

ber

of th

e ve

ntila

tion

unit;

con

side

r on

ly th

e le

tters

and

nu

mbe

rs m

entio

ned,

not

the

“xxx

”. E

. g.:

AV

S C

onst

ruct

o 1.

2 E

RV

with

ser

ial n

umbe

r LC

0115

2444

567

is fu

lly c

ompa

tible

with

Alti

tude

ver

sion

4.0

3 an

d D

eco-

Touc

h ve

rsio

n 2.

04 (L

C01

15 is

hig

her t

han

Lx01

14).

NO

TE

1:

Wal

l con

trol

incl

udin

g co

nfig

urab

le lo

w s

peed

rec

ircul

atio

n in

inte

rmitt

ent m

ode.

NO

TE

2:

Com

patib

le b

ut lo

w s

peed

rec

ircul

atio

n in

inte

rmitt

ent m

ode

is n

ot a

vaila

ble

for

this

uni

t.N

OT

E 3

: T

he c

ompa

tibili

ty s

tart

s fr

om th

at u

nit s

eria

l num

ber,

but r

ecirc

ulat

ion

mod

e is

not

ava

ilabl

e fo

r th

is u

nit.

NO

TE

4:

Low

spe

ed r

ecirc

ulat

ion

in in

term

itten

t mod

e st

arts

with

this

uni

t ser

ial n

umbe

r. H

owev

er, t

his

cont

rol r

emai

ns c

ompa

tible

with

uni

ts w

ith s

eria

l num

ber

unde

r th

is o

ne.

Sub

ject

to c

hang

e w

ithou

t prio

r no

tice. ww

w.ve

nmar

.ca90

310

Resid

entia

l Pro

duct

s Gro

up, 5

50 L

emire

Blvd

., Dru

mm

ondv

ille,

Qc, C

anad

a J2

C 7W

9 - T

el.: 1

-800

-567

-385

5 Fa

x: 1-

800-

567-

1715

Mod

el n

o.N

ame

Alti

tude

ver

sion

3.0

1M

odel

no.

404

40

Alti

tude

ver

sion

4.0

4M

odel

no.

404

45(N

OT

E 1

)

Dec

o-To

uch

vers

ion

2.01

Mod

el n

o. 4

0395

Dec

o-To

uch

vers

ion

2.04

Mod

el n

o. 4

0400

(NO

TE

1)

Lite

-Tou

ch

Con

stru

cto

Sim

ple-

Touc

h C

onst

ruct

oC

onst

ruct

o20

/40/

60

min

utes

4391

1 &

439

10A

VS

ER

V E

KO

1.5

NO

TE

2N

OT

E 2

4390

1 &

439

00A

VS

HR

V E

KO

1.5

NO

TE

2N

OT

E 2

4313

0A

VS

Con

stru

cto

1.5V

PC

1312

11xx

xxx

NO

TE

3P

C13

1211

xxxx

x N

OT

E 3

4112

1A

VS

Nov

ofit

1.0

NO

TE

2N

OT

E 2

4370

0, 4

3710

, & 4

5700

AV

S D

uo 1

.4, A

VS

Duo

1.2

& A

VS

Duo

1.9

4411

2, 4

4133

Kub

ix E

RV

NO

TE

2N

OT

E 2

4410

2, 4

4103

Kub

ix H

RV

Plu

sN

OT

E 2

NO

TE

2

4415

0K

ubix

HR

V

4311

0 &

160

1602

HR

V C

onst

ruct

o 1.

5

4511

0 &

160

1612

HR

V C

onst

ruct

o 2.

0

4311

5 &

451

15E

RV

Con

stru

cto

Qua

ttro

1.5

& Q

uattr

o 2.

0

4372

0 &

467

25S

olo

1.5

4572

0 &

457

25S

olo

2.0

4155

6 &

415

54A

VS

Con

stru

cto

1.2

ER

VL

x011

4xxx

xxxx

N

OT

E 4

Lx0

114x

xxxx

xxN

OT

E 4

4340

01.

3 H

E

4330

030

55 C

ompa

ct

4530

045

85 C

ompa

ct