vnx doc

102
Introduction The XML version of the data is encrypted and sent to your service provider. The following information is available in each tab: The storage system configuration display feature provides an easy-to-understand v configuration data generated by the storage system. Note that no configuration da portion of a VNX system is included. Hardware tab - Displays information related to System Information, SPs and replaceable units, drive modules, disk enclosure layout and environment. Software tab - Displays information on all software packages installed, inc of each package. This tab also displays replication software information. Storage tab - Displays information related to storage groups, RAID groups, metaLUNs, pool LUNs, Compression and FAST. SAN tab - Displays information related to any connected hosts (servers), in Mappings, Virtual Machines and Virtual Machine LUN Mappings. View All tab - Displays information from all tabs. View XML Source tab - Includes the XML source information that is sent to y provider in encrypted format. Note: Information highlighted in red requires attention and should be addressed a System Configuration Viewer Engine revision: 1.1.32.1.0042 Introduction Registration Details Issues XML File Information System Information SPs and Ports I_O Module Information Replaceable Units Drive Modules Disk Enclosure Layout Environment Software Packages MirrorView_Asynchronous MirrorView_Synchronous SAN Copy SnapView SnapView sessions and snapshots

Upload: amir-salihovic

Post on 29-Oct-2014

50 views

Category:

Documents


6 download

DESCRIPTION

vnx doc

TRANSCRIPT

Page 1: vnx doc

Introduction

The XML version of the data is encrypted and sent to your service provider.

The following information is available in each tab:

The storage system configuration display feature provides an easy-to-understand view of the XML configuration data generated by the storage system. Note that no configuration data for the File portion of a VNX system is included.

Hardware tab - Displays information related to System Information, SPs and ports, I/O modules, replaceable units, drive modules, disk enclosure layout and environment.

Software tab - Displays information on all software packages installed, including the revision of each package. This tab also displays replication software information.

Storage tab - Displays information related to storage groups, RAID groups, pools, LUNs, metaLUNs, pool LUNs, Compression and FAST.

SAN tab - Displays information related to any connected hosts (servers), initiators, LUN Mappings, Virtual Machines and Virtual Machine LUN Mappings.View All tab - Displays information from all tabs.

View XML Source tab - Includes the XML source information that is sent to your service provider in encrypted format.

Note: Information highlighted in red requires attention and should be addressed as soon as possible.

System Configuration Viewer Engine revision: 1.1.32.1.0042

IntroductionRegistration DetailsIssuesXML File InformationSystem InformationSPs and PortsI_O Module InformationReplaceable UnitsDrive ModulesDisk Enclosure LayoutEnvironmentSoftware PackagesMirrorView_AsynchronousMirrorView_SynchronousSAN CopySnapViewSnapView sessions and snapshots

Page 2: vnx doc

SnapView clonesStorage GroupsRAID GroupsPoolsLUNs OverviewmetaLUN InformationPool LUNsCompressionFAST HostsInitiatorsLUN MappingsVirtual MachinesVirtual Machine LUN Mappings

Page 3: vnx doc

The storage system configuration display feature provides an easy-to-understand view of the XML configuration data generated by the storage system. Note that no configuration data for the File portion of a VNX system is included.

- Displays information related to System Information, SPs and ports, I/O modules, replaceable units, drive

- Displays information on all software packages installed, including the revision of each package. This tab

- Displays information related to storage groups, RAID groups, pools, LUNs, metaLUNs, pool LUNs,

- Displays information related to any connected hosts (servers), initiators, LUN Mappings, Virtual Machines and

- Includes the XML source information that is sent to your service provider in encrypted format.

Page 4: vnx doc

Registration DetailsNo Registration information is available on this storage system 

Page 5: vnx doc

XML File Information

Comments

Generated by SP SPA

Name

Comments

Generated by SP SPA

Name

VNX 5300 username admin

Password emc

MDS switch admin

password cisco

SAN XML DetailsMeta Version 1.0 

Schema Version 02.02 

Configuration Capture and Duplication Feature 

XML Generator ApplicationCCD Feature 

Application Version 7.31.0.4.16 

Application Date 05/22/12 09:18:02

Storage System XML DetailsMeta Version 1.0 

Schema Version 03.08 

Configuration Capture and Duplication Feature 

XML Generator ApplicationCCD Feature 

Application Version 7.31.0.4.16 

Application Date 05/22/12 09:18:03

Page 6: vnx doc

System InformationSystem Information

Model Number VNX5300

Hardware Type VNX

System Type Block

System Name VNX5300-STD

System Serial # CKM00113100934

SPA IP 192.168.1.32

SPB IP 192.168.1.33

Page 7: vnx doc

SPs and PortsSP A SP B

Model

Revision 05.31.000.5.008 05.31.000.5.008

Memory

WWN

IP

Gateway

IPv6

No

SNMP InformationSNMP Is Enabled Disabled Disabled

Comminity String None None

VLAN Details For ManagementPortVLAN Enabled Disabled Disabled

VLAN ID 0 0

Temperature InformationIs Self Temperature Sensor Faulted No No

Is Self Ambient Over Temperature No No

Is Self Shutting Down No No

Is Peer Temperature Sensor Faulted No No

Is Peer Ambient Over Temperature No No

Is Peer Shutting Down No No

Fast Cache InformationIs Faulted

State

Mode

Raid Type

Operation

Operation State

Size

SP Memory Consumption

Storage System Serial Number CKM00113100934 

SP Serial Number CF2J8111600026  CF2J9111500243 

VNX5300 

PROM Revision 6.10.0  6.10.0 

8192  8192 

Statistics Logging Enabled  Enabled 

50:06:01:60:BE:A0:1B:89 

LUN OwnershipDefault number LUNs owned 6   5  

LUNs currently assigned 5   5  

Agent InfoNetwork Name A-IMAGE   B-IMAGE  

192.168.1.32   192.168.1.33  

Subnet Mask 255.255.255.0   255.255.255.0  

192.168.1.254   192.168.1.254  

None   None  

IPv6 Gateway None   None  

ClassicCLI Support

FastCache is not configured on this storage system FastCache enabler is not installed on

this storage system

Page 8: vnx doc

Disks

SP Port Type

Backend Bus Information

SP Bus Speed (Gbps)B 1 0

B 0 128

A 1 0

A 0 128

SP Port Info

A  0  Fibre Channel 

A  1  Fibre Channel 

A  2  Fibre Channel 

A  3  Fibre Channel 

B  0  Fibre Channel 

B  1  Fibre Channel 

B  2  Fibre Channel 

B  3  Fibre Channel 

Page 9: vnx doc

SP A SP BEnabled Enabled

Enabled Enabled

Yes Yes

622MB 622MB

2160MB 2160MB

8 8

0MB 0MB

GWCA Enabled Enabled

SP Cache Information

Read Cache State

Write Cache State

Write Cache Mirrored

Free Memory 0MB   0MB  

Read Cache Size

Write Cache Size

Cache Page Size

Low Watermark 60 

High Watermark 80 

HA Cache Vault Disabled  Disabled 

Opt. RAID 3 Memory Size

Page 10: vnx doc

Speed

WWN

Status

(Gbps) Link8 Up

8 Up

N/A Down

N/A Down

8 Up

8 Up

N/A Down

N/A Down

Backend Bus Information

Available Speeds (Gbps) Is Max Enclosures Exceeded64, 128 No

64, 128 No

64, 128 No

64, 128 No

SP Port Info

50:06:01:60:BE:A0:1B:89:50:06:01:60:3E:A0:1B:89 

50:06:01:60:BE:A0:1B:89:50:06:01:61:3E:A0:1B:89 

50:06:01:60:BE:A0:1B:89:50:06:01:62:3E:A0:1B:89 

50:06:01:60:BE:A0:1B:89:50:06:01:63:3E:A0:1B:89 

50:06:01:60:BE:A0:1B:89:50:06:01:68:3E:A0:1B:89 

50:06:01:60:BE:A0:1B:89:50:06:01:69:3E:A0:1B:89 

50:06:01:60:BE:A0:1B:89:50:06:01:6A:3E:A0:1B:89 

50:06:01:60:BE:A0:1B:89:50:06:01:6B:3E:A0:1B:89 

Page 11: vnx doc

Power Saving Feature DetailsSystem Default Idle Time(min) 30

Min Latency Tolerance 120

Is Global Power Saving Enabled FALSE

Is Power Saving Stats Logging Enabled FALSE

Page 12: vnx doc

Status

Is Switch

HBA Fan-Out

ALPAPort RegisteredOnline

Online

Disabled

Disabled

Online

Online

Disabled

Disabled

Logged InYes   4  4  0 

Yes   4  4  0 

No   0  0  0 

No   0  0  0 

Yes   4  4  0 

Yes   4  4  0 

No   0  0  0 

No   0  0  0 

Page 13: vnx doc

Switch WWN Source ID

None

None

None

None

20:88:00:05:73:F1:72:79:20:02:00:05:73:F1:72:78 

8782336 

20:88:00:05:73:F1:72:79:20:01:00:05:73:F1:72:78 

8781824 

239 

239 

20:88:00:05:73:F1:72:79:20:04:00:05:73:F1:72:78 

8782848 

20:88:00:05:73:F1:72:79:20:03:00:05:73:F1:72:78 

8782592 

239 

239 

Page 14: vnx doc

I/O Module InformationI/O Module

SP Slot ID I/O Module SLIC Type SLIC Class State Sub-State Power State I/O CarrierA Onboard Multi Protocol N/A Onboard Present Good On No

A Onboard Multi Protocol N/A Onboard Present Good On No

A Onboard Multi Protocol N/A Onboard Present Good On No

A Onboard Multi Protocol N/A Onboard Present Good On No

A Onboard Multi Protocol N/A Onboard Present Good On No

A Onboard Multi Protocol N/A Onboard Present Good On No

A 1 Unknown Unknown SLIC Empty Not Present Not Available No

A 0 Unknown Unknown SLIC Empty Not Present Not Available No

B Onboard Multi Protocol N/A Onboard Present Good On No

B Onboard Multi Protocol N/A Onboard Present Good On No

B Onboard Multi Protocol N/A Onboard Present Good On No

B Onboard Multi Protocol N/A Onboard Present Good On No

B Onboard Multi Protocol N/A Onboard Present Good On No

B Onboard Multi Protocol N/A Onboard Present Good On No

B 1 Unknown Unknown SLIC Empty Not Present Not Available No

B 0 Unknown Unknown SLIC Empty Not Present Not Available No

Page 15: vnx doc

I/O Module Physical Port

Is Peer Onboard Inserted Physical Port Logical ID I/O Module Group Role UsageYes 0 0 3 BE Normal

Yes 1 1 3 BE Normal

Yes 2 0 4 FE Special

Yes 3 1 4 FE Normal

Yes 4 2 4 FE Normal

Yes 5 3 4 FE Normal

N/A N/A N/A N/A N/A N/A

N/A N/A N/A N/A N/A N/A

Yes 0 0 3 BE Normal

Yes 1 1 3 BE Normal

Yes 2 0 4 FE Special

Yes 3 1 4 FE Normal

Yes 4 2 4 FE Normal

Yes 5 3 4 FE Normal

N/A N/A N/A N/A N/A N/A

N/A N/A N/A N/A N/A N/A

Page 16: vnx doc

Physical Port

Type State Sub-State Persisted SFP EMC Part NumberSAS Enabled Good Yes None

SAS Enabled Good Yes None

Enabled Good Yes 019-078-042

Enabled Good Yes 019-078-042

Missing SFP is missing Yes None

Missing SFP is missing Yes None

N/A N/A N/A N/A None

N/A N/A N/A N/A None

SAS Enabled Good Yes None

SAS Enabled Good Yes None

Enabled Good Yes 019-078-042

Enabled Good Yes 019-078-042

Missing SFP is missing Yes None

Missing SFP is missing Yes None

N/A N/A N/A N/A None

N/A N/A N/A N/A None

Fibre Channel

Fibre Channel

Fibre Channel

Fibre Channel

Fibre Channel

Fibre Channel

Fibre Channel

Fibre Channel

Page 17: vnx doc

Physical Port

SFP EMC Serial Number SFP Vendor Part Number SFP Vendor Serial NumberNone None None

None None None

0 FTLF8528P2BNV-E5 PKD0VZQ

0 FTLF8528P2BNV-E5 PKC379T

None None None

None None None

None None None

None None None

None None None

None None None

0 FTLF8528P2BNV-E5 PKD128M

0 FTLF8528P2BNV-E5 PKC3967

None None None

None None None

None None None

None None None

Page 18: vnx doc

Replaceable Units

Type Name TLABus 0 Enclosure 2 100-562-904 US1V4112412499

Bus 0 Enclosure 1 100-562-904 US1V4111411065

Bus 0 Enclosure 0 100-562-503 FCNCH111200215

Type Component

EMC

Serial Number916  

916  

918  

Assembly Name Part NumberPower B    Third Gen 400W, Dual +12V P/S    Bus 0 Enclosure 2    071-000-518   

Power A    Third Gen 400W, Dual +12V P/S    Bus 0 Enclosure 2    071-000-518   

Power B    Third Gen 400W, Dual +12V P/S    Bus 0 Enclosure 1    071-000-518   

Power A    Third Gen 400W, Dual +12V P/S    Bus 0 Enclosure 1    071-000-518   

Power B    DUAL 12V P/S WITHOUT FAN    Bus 0 Enclosure 0    071-000-529   

Power A    DUAL 12V P/S WITHOUT FAN    Bus 0 Enclosure 0    071-000-529   

LCC B    15 DRIVE VIPER 6G SAS LCC FRU   Bus 0 Enclosure 2    303-108-000E  

LCC A    15 DRIVE VIPER 6G SAS LCC FRU   Bus 0 Enclosure 2    303-108-000E  

LCC B    15 DRIVE VIPER 6G SAS LCC FRU   Bus 0 Enclosure 1    303-108-000E  

LCC A    15 DRIVE VIPER 6G SAS LCC FRU   Bus 0 Enclosure 1    303-108-000E  

Chassis/Midplane    6G SAS LF DAE VIPER W/FLANGES   Bus 0 Enclosure 2    100-562-904  

Chassis/Midplane    6G SAS LF DAE VIPER W/FLANGES   Bus 0 Enclosure 1    100-562-904  

Chassis/Midplane    SENTRYLITE DUAL SP 8GB DVT AO   Bus 0 Enclosure 0    100-562-503  

SP B    SENTRYSP 1.60GHZ QC CPU   SP B    110-140-408B  

SP A    SENTRYSP 1.60GHZ QC CPU   SP A    110-140-408B  

Page 19: vnx doc

SP A

A B C D StateN/A N/A N/A N/A N/A

N/A N/A N/A N/A N/A

N/A N/A N/A N/A N/A

EMC Vendor

Enclosure Fans

Serial Number Assembly revision Artwork revision Part Number Serial Number  AC794111007125    A08   012   SG7008-710G   AC7111006888  

  AC794111007172    A08   012   SG7008-710G   AC7110907750  

  AC794111303815    A08   012   SG7008-710G   AC7111305111  

  AC794111303816    A08   012   SG7008-710G   AC7111305065  

  AC178111800644    A09   04I   SG7011-710G   AC1111800644  

  AC178111800439    A09   04I   SG7011-710G   AC1111800439  

  US1V2112502096   E11   E   N/A   N/A  

  US1V2112502003   E11   E   N/A   N/A  

  US1V2111400906   E10   E   N/A   N/A  

  US1V2111400913   E10   E   N/A   N/A  

  US1V4112412499   A07   N/A   N/A  

  US1V4111411065   A04   N/A   N/A  

  FCNCH111200215   A06   N/A   N/A  

  CF2J9111500243   B22   N/A   N/A   N/A  

  CF2J8111600026   B21   N/A   N/A   N/A  

Page 20: vnx doc

SP A

SPS LCCN/A N/A Present

N/A N/A Present

N/A N/A N/A

Vendor Manufacturer

Name Location Date03/14/2011

03/14/2011

1/4/2011

1/4/2011

10/5/2011

10/5/2011

4/7/2011

4/7/2011

04/14/2011

04/14/2011

Power Supply SPS CablingPresent   

Present   

Present   

Assembly NumberA08   ACBEL POLYTECH INC.   TANG XIA TOWN, DONG GUAN, CHINA  

A08   ACBEL POLYTECH INC.   TANG XIA TOWN, DONG GUAN, CHINA  

A08   ACBEL POLYTECH INC.   TANG XIA TOWN, DONG GUAN, CHINA  

A08   ACBEL POLYTECH INC.   TANG XIA TOWN, DONG GUAN, CHINA  

A09   ACBEL POLYTECH INC.   MANILA, PHILIPPINES  

A09   ACBEL POLYTECH INC.   MANILA, PHILIPPINES  

N/A   USI   Shanghai,China  

N/A   USI   Shanghai,China  

N/A   USI   Shanghai,China  

N/A   USI   Shanghai,China  

N/A   N/A   N/A   N/A 

N/A   N/A   N/A   N/A 

N/A   N/A   N/A   N/A 

N/A   N/A   N/A   N/A 

N/A   N/A   N/A   N/A 

Page 21: vnx doc

SP A SP B

State1.21 US1V2112502003 N/A N/A

1.21 US1V2111400913 N/A N/A

N/A N/A N/A N/A

Program

Name Revision

LCC revision LCC Serial Number LCC Type Power SupplyPresent   

Present   

Present   

Micro   5.17  

Micro   5.17  

Micro   5.17  

Micro   5.17  

PS FW   0.27  

PS FW   0.27  

CDES   1.21  

CDES   1.21  

CDES   1.21  

CDES   1.21  

N/A   N/A  

N/A   N/A  

N/A   N/A  

BIOS:POST:MCU:MCU BB:PLX8608   6.10:39.50:5.10:1.10:3.04  

BIOS:POST:MCU:MCU BB:PLX8608   6.10:39.50:5.10:1.10:3.04  

Page 22: vnx doc

SP B

SPS LCCN/A N/A Present 1.21 US1V2112502096 N/A

N/A N/A Present 1.21 US1V2111400906 N/A

N/A N/A N/A N/A N/A N/A

SPS Cabling LCC revision LCC Serial Number LCC Type

Page 23: vnx doc

Drive ModulesNumber of Drives 39

Bus Enclosure Slot/Bank Slot RAID Group Size (GB) Drive Type Manufacturer0 0 0 Unbound 268 SAS SEAGATE

0 0 1 Unbound 268 SAS SEAGATE

0 0 2 Unbound 268 SAS SEAGATE

0 0 3 Unbound 268 SAS SEAGATE

0 0 4 0 268 SAS SEAGATE

0 0 5 0 268 SAS SEAGATE

0 0 6 0 268 SAS SEAGATE

0 0 7 0 268 SAS SEAGATE

0 0 8 0 268 SAS SEAGATE

0 0 9 0 268 SAS SEAGATE

0 0 10 0 268 SAS SEAGATE

0 0 11 0 268 SAS SEAGATE

0 0 12 0 268 SAS SEAGATE

0 0 13 0 268 SAS SEAGATE

0 0 14 1 268 SAS SEAGATE

0 1 0 Unbound 268 SAS SEAGATE

0 1 1 Unbound 268 SAS SEAGATE

0 1 2 Unbound 268 SAS SEAGATE

0 1 3 Unbound 268 SAS SEAGATE

0 1 4 Unbound 268 SAS SEAGATE

0 1 5 Unbound 268 SAS SEAGATE

0 1 6 Unbound 268 SAS SEAGATE

0 1 7 Unbound 268 SAS SEAGATE

0 1 8 Unbound 268 SAS SEAGATE

0 1 9 Unbound 268 SAS SEAGATE

0 1 10 Unbound 268 SAS SEAGATE

0 1 11 Unbound 268 SAS SEAGATE

0 1 12 Unbound 268 SAS SEAGATE

0 1 13 Unbound 268 SAS SEAGATE

0 1 14 Unbound 268 SAS SEAGATE

0 2 0 Unbound 268 SAS SEAGATE

0 2 1 Unbound 268 SAS SEAGATE

0 2 2 Unbound 268 SAS SEAGATE

0 2 3 Unbound 268 SAS SEAGATE

0 2 4 Unbound 268 SAS SEAGATE

0 2 5 Unbound 268 SAS SEAGATE

0 2 6 Unbound 268 SAS SEAGATE

0 2 7 Unbound 268 SAS SEAGATE

0 2 8 Unbound 268 SAS SEAGATE

0 2 9 None None None None

0 2 10 None None None None

Page 24: vnx doc

0 2 11 None None None None

0 2 12 None None None None

0 2 13 None None None None

0 2 14 None None None None

Page 25: vnx doc

Model Serial Number Part Number TLA Number Firmware RevisionSTE30065 CLAR300 6SJ1EP6C DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1DRZE DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1E9L7 DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1DJT9 DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1EQSE DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1EQYM DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1EQQS DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1EGE7 DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ0TEGC DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1EQW4 DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1EQYZ DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1EQP4 DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1EQMX DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1DNCA DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1GRX1 DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1NAEP DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1N8BG DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1NCKC DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1NALG DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1J8TC DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1NAEN DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1N8A5 DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1N8AN DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1L7XW DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1JSC6 DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1JYWW DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1KC1R DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1AFQA DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1K3AN DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ2CW4J DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1JR7Z DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1KAML DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1JS3D DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1ERMS DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1KB6T DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ28MCC DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1K890 DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1KC72 DG118032654 5049273 ES0E

STE30065 CLAR300 6SJ1KBC3 DG118032654 5049273 ES0E

None None None None None

None None None None None

Page 26: vnx doc

None None None None None

None None None None None

None None None None None

None None None None None

Page 27: vnx doc

State Hot Spare Replacing Current Speed (Gbps) Maximum Speed (Gbps)Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Enabled N/A 128 128

Enabled N/A 128 128

Enabled N/A 128 128

Enabled N/A 128 128

Enabled N/A 128 128

Enabled N/A 128 128

Enabled N/A 128 128

Enabled N/A 128 128

Enabled N/A 128 128

Enabled N/A 128 128

Hot Spare Ready Inactive 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Unbound N/A 128 128

Empty N/A None None

Empty N/A None None

Page 28: vnx doc

Empty N/A None None

Empty N/A None None

Empty N/A None None

Empty N/A None None

Page 29: vnx doc

Is Hardware Qualified Is Hardware Capable Power Saving StateNo No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Full power

No No Removed

No No Removed

Power Saving

Page 30: vnx doc

No No Removed

No No Removed

No No Removed

No No Removed

Page 31: vnx doc

Disk Enclosure LayoutDisk Enclosure Layout

Front View - RAID Group/(Disk Size)Bus0 Bank ID 0 1 2 3 4 5 6 7

Bus0,Encl2 N/A U U U U U U U U

-268 -268 -268 -268 -268 -268 -268 -268

Bus0,Encl1 N/A U U U U U U U U

-268 -268 -268 -268 -268 -268 -268 -268

Bus0,Encl0 N/A U U U U 0 0 0 0

-268 -268 -268 -268 -268 -268 -268 -268

DG118032654 DG118032654 DG118032654 DG118032654

ES0E ES0E ES0E ES0E

Bus0 Bank ID 0 1 2 3 4 5 6 7

Legend RAID-0    

RAID-1    

RAID-1/0    

RAID-3    

RAID-5    

RAID-6    

Hot Spare    

Individual    

Unbound  U 

Empty    

Page 32: vnx doc

Disk Enclosure Layout

Front View - RAID Group/(Disk Size)8 9 10 11 12 13

U

-268

U U U U U U

-268 -268 -268 -268 -268 -268

0 0 0 0 0 0

-268 -268 -268 -268 -268 -268

DG118032654 DG118032654 DG118032654 DG118032654 DG118032654 DG118032654

ES0E ES0E ES0E ES0E ES0E ES0E

8 9 10 11 12 13

Page 33: vnx doc

Disk Enclosure Layout

Front View - RAID Group/(Disk Size)14

U

-268

1

-268

DG118032654

ES0E

14

Line Number Value1 RAID Group ID

2 (<Size of disk in GB>)

3 CLARiiON Part Number

4 Revision Number

For each disk cell, each row of text is the following

Page 34: vnx doc

EnvironmentSubsystem Environment Information

Input Power - Present (W) Input Power - Rolling Average (W)754 752

Cabinet Environment Information

Cabinet

Input Power (W)

Present

Bus 0 Enclosure 2 130

Bus 0 Enclosure 1 194

Bus 0 Enclosure 0 418

SPS Environment Information

SPS Input Power - Present (W)

Page 35: vnx doc

Cabinet Environment Information

Input Power (W) Inlet Air Temperature (C)

Rolling Average Present Rolling Average

130 18 17

196 19 18

414 19 18

SPS Environment Information

Input Power - Rolling Average (W)

Page 36: vnx doc

Software PackagesCurrent NDUs

Software Revision ActiveNeeds CommitAnalyzerProvider   1.1.0.1.0416   No   Yes  

Base   05.31.000.5.008   No   Yes  

CLIProvider   1.1.0.1.0416   No   Yes  

DriveFirmware   05.31.007.5.005   No   Yes  

EFDCacheEngine   05.31.007.5.006   No   Yes  

FASTCacheConfigs   05.31.007.5.005   No   Yes  

ManagementServer   1.1.0.1.0416   No   Yes  

ManagementUI   1.1.0.1.0387   No   Yes  

MirrorProvider   1.1.0.1.0416   No   Yes  

MirrorView   05.31.007.5.006   No   Yes  

MirrorView/A   05.31.007.5.005   No   Yes  

MLUEngine   05.31.007.5.006   No   Yes  

Navisphere   1.1.0.1.0416   No   Yes  

NDISDriverUpdate   05.31.007.5.005   No   Yes  

PolicyEngine   05.31.007.5.005   No   Yes  

QoSManagerProvider   1.1.0.1.0416   No   Yes  

RecoverPointSplitter   05.31.007.5.005   No   Yes  

RemotelyAnywhere   05.31.5.005   No   Yes  

SANCopy   05.31.007.5.005   No   Yes  

SANCopyProvider   1.1.0.1.0416   No   Yes  

SecurityPolicy   05.31.007.5.005   No   Yes  

SIWRules   1.1.0.1.0416   No   Yes  

SnapCloneProvider   1.1.0.1.0416   No   Yes  

SnapView   05.31.007.5.005   No   Yes  

SnapViewProvider   1.1.0.1.0416   No   Yes  

SNMP   05.31.007.5.005   No   Yes  

SXP36x6gLccFw   01015.006   No   Yes  

VNX-Block-Operating-Environment   05.31.000.5.008   No   Yes  

Page 37: vnx doc

Enablers

Software Active-Compression   Yes  

-SANCopy   Yes  

-ThinProvisioning   Yes  

-Unisphere   Yes  

-UnisphereBlock   Yes  

Page 38: vnx doc

MirrorView/AsynchronousNo Asynchronous Mirrors are configured on this storage system

Asynchronous Mirror enabler is not installed on this storage system. 

Page 39: vnx doc

No Asynchronous Mirrors are configured on this storage system

Asynchronous Mirror enabler is not installed on this storage system. 

Page 40: vnx doc

MirrorView/Synchronous

LUN Name

General Mirror Information

Name Description State Faulted QThreshold Image CountNo Synchronous Mirrors are configured on this storage system

Synchronous Mirror enabler is not installed on this storage system. 

Page 41: vnx doc

General Mirror Information

WriteIntent Log Transitioning Minimum # Images Image StateNo Synchronous Mirrors are configured on this storage system

Synchronous Mirror enabler is not installed on this storage system. 

Page 42: vnx doc

General Mirror Information Primary Image

Recovery Policy Sync Rate Storage System UID LUN UID LUN ConditionNo Synchronous Mirrors are configured on this storage system

Synchronous Mirror enabler is not installed on this storage system. 

Page 43: vnx doc

Secondary Image

Storage System UID LUN UID LUN Condition

Page 44: vnx doc

SAN Copy

Global2

10

4

1024

Descriptor Session

Name ID SP Type Source Targets

Max Sessions

Checkpoint (min)

Buffers per Session

Default Buffer Size

Source Blocks Blocks to CopyNo SAN Copy Sessions are configured on this storage system.

Page 45: vnx doc

Session

Destination

Dest LUN Number Block AddressLUN Name Transfer Count Failure Status Completion TimeNo SAN Copy Sessions are configured on this storage system.

Page 46: vnx doc

Session

Destination

StatusUser Connection Type Actual Connection Type Actual Location Type Initial Throttle

Page 47: vnx doc

Session

CompleteCurrent Throttle Transfer Count Completion Time Failure Status

Page 48: vnx doc

SnapView

Global

SnapCache

Name LUN Is Incremental State Session UID LUN Usage

Snapshot Cache Summary

Storage SystemUnused LUNs None  

Total size (GB) None  

Total used (%) None  

Current Snapshots

Storage SystemNo Snapshots are configured on this storage system

SnapView enabler is not installed on this storage system. 

Page 49: vnx doc

No Snapshots are configured on this storage system

SnapView enabler is not installed on this storage system. 

Page 50: vnx doc

SnapView sessions and snapshots

Name Time Simulation State Persistent

SP Usage

Source LUNsGB #COFW Current

Owner SP

No SnapView Sessions are configured on this storage system

SnapView enabler is not installed on this storage system. 

Page 51: vnx doc

Active SnapshotsNo SnapView Sessions are configured on this storage system

SnapView enabler is not installed on this storage system. 

Page 52: vnx doc

SnapView clones

SP A None

SP B None

None

None

Name UID In Sync Description

Clone Private LUNs Summary InformationMaxClone Groups None  

MaxClones Per Group None  

Available LUNs to Clone 0  1  2  3  4  5  6  7  8  9  4089 

Allow Protected Restore

Driver Version

Quiesce ThresholdNo SnapView Clones are configured on this storage system

SnapView enabler is not installed on this storage system. 

Page 53: vnx doc

Size Source LUNs

Clone Information

Clone LUN Clone ID State Condition Available For IO Is DirtyNo SnapView Clones are configured on this storage system

SnapView enabler is not installed on this storage system. 

Page 54: vnx doc

Clone Information

Percent Synched Recovery Policy Sync Rate Use Protected Restore Is Fractured

Page 55: vnx doc

Storage Groups

Name UID Shareable

LUN Index

Hostdb1 Yes 9 4

8 3

7 2

6 1

5 0

4 9

3 8

2 7

1 6

0 5

db2 Yes 9 4

8 3

7 2

6 1

5 0

4 9

3 8

2 7

1 5

0 6

db3 Yes None None

db4 Yes None None

Storage system0A:6A:4B:7F:9D:72:E1:11:88:50:00:60:16:37:E1:99

24:CA:80:8E:9D:72:E1:11:88:50:00:60:16:37:E1:99

6C:A5:F2:94:9D:72:E1:11:88:50:00:60:16:37:E1:99

6D:A5:F2:94:9D:72:E1:11:88:50:00:60:16:37:E1:99

Page 56: vnx doc

HBA

Path Count Port UID4 A0 20:00:00:25:B5:10:00:6F:20:00:00:25:B5:00:00:6F

B1 20:00:00:25:B5:10:00:6F:20:00:00:25:B5:00:00:6F

A1 20:00:00:25:B5:10:00:6F:20:00:00:25:B5:00:00:6F

B0 20:00:00:25:B5:10:00:6F:20:00:00:25:B5:00:00:6F

4 B1 20:00:00:25:B5:20:00:6F:20:00:00:25:B5:00:00:8F

A1 20:00:00:25:B5:20:00:6F:20:00:00:25:B5:00:00:8F

B0 20:00:00:25:B5:20:00:6F:20:00:00:25:B5:00:00:8F

A0 20:00:00:25:B5:20:00:6F:20:00:00:25:B5:00:00:8F

4 B1 20:00:00:25:B5:30:00:6F:20:00:00:25:B5:00:00:9F

A1 20:00:00:25:B5:30:00:6F:20:00:00:25:B5:00:00:9F

B0 20:00:00:25:B5:30:00:6F:20:00:00:25:B5:00:00:9F

A0 20:00:00:25:B5:30:00:6F:20:00:00:25:B5:00:00:9F

4 B1 20:00:00:25:B5:40:00:6F:20:00:00:25:B5:00:00:7F

A1 20:00:00:25:B5:40:00:6F:20:00:00:25:B5:00:00:7F

B0 20:00:00:25:B5:40:00:6F:20:00:00:25:B5:00:00:7F

A0 20:00:00:25:B5:40:00:6F:20:00:00:25:B5:00:00:7F

Page 57: vnx doc

RAID Groups

RAID Group RAID Type Total Free0 RAID1/0 2799093760 597084160 597084160

1 HotSpare 558854144 0 0

Space in blocks(512 bytes)

Free contiguous

Page 58: vnx doc

RAID Group

LUNsPower Saving EligibleNo 0 1 2 3 4 5 6 7 8 9

No 4089

Page 59: vnx doc

PoolsPools are not configured on this storage system

Page 60: vnx doc

Pools are not configured on this storage system

Page 61: vnx doc

LUNs Overview

Number of LUNs 11

LUN Name LUN ID State RAID TypeSIS0 0 Bound RAID1/0

SIS1 1 Bound RAID1/0

SIS2 2 Bound RAID1/0

SIS3 3 Bound RAID1/0

SIS4 4 Bound RAID1/0

SIS5 5 Bound RAID1/0

SIS6 6 Bound RAID1/0

SIS7 7 Bound RAID1/0

SIS8 8 Bound RAID1/0

SIS9 9 Bound RAID1/0

Hot Spare LUN 4089 4089 Bound Unassigned HS

  

Storage Pool/ RAID GroupRAID Group 0

RAID Group 0

RAID Group 0

RAID Group 0

RAID Group 0

RAID Group 0

RAID Group 0

RAID Group 0

RAID Group 0

RAID Group 0

RAID Group 1

Page 62: vnx doc

Storage Group Auto Assign Auto TrespassDefault Current107520 B B db1, Disabled Disabled

db2

107520 B B db1, Disabled Disabled

db2

107520 B B db1, Disabled Disabled

db2

107520 B B db1, Disabled Disabled

db2

107520 B B db1, Disabled Disabled

db2

107520 A A db1, Disabled Disabled

db2

107520 A A db1, Disabled Disabled

db2

107520 A A db1, Disabled Disabled

db2

107520 A A db1, Disabled Disabled

db2

107520 A A db1, Disabled Disabled

db2

274666 A N/A None Enabled

Capacity (MB) Owner SP

User Capacity (MB)

Page 63: vnx doc

SP Read Cache SP Write Cache FastCache Offset UIDEnabled Enabled N/A 0 60:06:01:60:1A:00:2D:00:A6:83:0E:22:F3:56:

Enabled Enabled N/A 0 60:06:01:60:1A:00:2D:00:A7:83:0E:22:F3:56:

Enabled Enabled N/A 0 60:06:01:60:1A:00:2D:00:A8:83:0E:22:F3:56:

Enabled Enabled N/A 0 60:06:01:60:1A:00:2D:00:A9:83:0E:22:F3:56:

Enabled Enabled N/A 0 60:06:01:60:1A:00:2D:00:AA:83:0E:22:F3:56:

Enabled Enabled N/A 0 60:06:01:60:1A:00:2D:00:AB:83:0E:22:F3:56:

Enabled Enabled N/A 0 60:06:01:60:1A:00:2D:00:AC:83:0E:22:F3:56:

Enabled Enabled N/A 0 60:06:01:60:1A:00:2D:00:AD:83:0E:22:F3:56:

Enabled Enabled N/A 0 60:06:01:60:1A:00:2D:00:AE:83:0E:22:F3:56:

Enabled Enabled N/A 0 60:06:01:60:1A:00:2D:00:AF:83:0E:22:F3:56:

Disabled Disabled N/A 0 60:06:01:60:1A:00:2D:00:F4:B2:87:1B:F4:56:E1:11

Page 64: vnx doc

60:06:01:60:1A:00:2D:00:F4:B2:87:1B:F4:56:E1:11

Page 65: vnx doc

metaLUN InformationSummary

Supported

Name LUN Index Expandable Expanded Total Size Usable Size

Yes 

Number of metaLUNs 0 

Max metaLUNs 512 

Max Components 8 

Max LUNs/Component 32 

metaLUN Detail

No metaLUNs configured on this storage system 

Page 66: vnx doc

Components

Configured Size UID ID LUN Name WWN RAID Group RAID TypeNo metaLUNs configured on this storage system 

Page 67: vnx doc

Pool LUNsNo Pool LUNs configured on this storage system 

Page 68: vnx doc

Compression0

On

Number of Compression Sessions

Compression Feature State 

LUN Name Compression State Percent Complete (%)No Compression Sessions are configured on this storage system.

Page 69: vnx doc

Compression Rate User Capacity (GB) Consumed Capacity (GB) Destination Pool NameNo Compression Sessions are configured on this storage system.

Page 70: vnx doc

No Compression Sessions are configured on this storage system.

Page 71: vnx doc

FAST FAST Sessions have not been configured on this storage system

FAST enabler is not installed on this storage system. 

Page 72: vnx doc

FAST Sessions have not been configured on this storage system

FAST enabler is not installed on this storage system. 

Page 73: vnx doc

Hosts

Host IP ManagedA-IMAGE  192.168.1.32  Yes 

B-IMAGE  192.168.1.33  Yes 

db1.sau.edu.sa  10.98.136.1  No 

db2.sau.edu.sa  10.98.136.2  No 

db3.sau.edu.sa  UNKNOWN  Yes 

db4.sau.edu.sa  UNKNOWN  Yes 

Page 74: vnx doc

Manually LUN

Registered CountPoll TypeNo  N/A  0 

No  N/A  0 

No  Agent  10 

No  Agent  10 

No  N/A  0 

No  N/A  0 

Page 75: vnx doc

Operating System

Page 76: vnx doc

Operating System Version

Page 77: vnx doc

InitiatorsHost IP UID Port

db3.sau.edu.sa UNKNOWN

db3.sau.edu.sa UNKNOWN

db3.sau.edu.sa UNKNOWN

db3.sau.edu.sa UNKNOWN

db1.sau.edu.sa 10.98.136.1

db1.sau.edu.sa 10.98.136.1

db1.sau.edu.sa 10.98.136.1

db1.sau.edu.sa 10.98.136.1

db4.sau.edu.sa UNKNOWN

db4.sau.edu.sa UNKNOWN

db4.sau.edu.sa UNKNOWN

db4.sau.edu.sa UNKNOWN

db2.sau.edu.sa 10.98.136.2

db2.sau.edu.sa 10.98.136.2

db2.sau.edu.sa 10.98.136.2

db2.sau.edu.sa 10.98.136.2

Device Driver20:00:00:25:B5:30:00:6F:20:00:00:25:B5:00:00:9F  B 1

20:00:00:25:B5:30:00:6F:20:00:00:25:B5:00:00:9F  A 1

20:00:00:25:B5:30:00:6F:20:00:00:25:B5:00:00:9F  B 0

20:00:00:25:B5:30:00:6F:20:00:00:25:B5:00:00:9F  A 0

20:00:00:25:B5:10:00:6F:20:00:00:25:B5:00:00:6F  A 0

20:00:00:25:B5:10:00:6F:20:00:00:25:B5:00:00:6F  B 1

20:00:00:25:B5:10:00:6F:20:00:00:25:B5:00:00:6F  A 1

20:00:00:25:B5:10:00:6F:20:00:00:25:B5:00:00:6F  B 0

20:00:00:25:B5:40:00:6F:20:00:00:25:B5:00:00:7F  B 1

20:00:00:25:B5:40:00:6F:20:00:00:25:B5:00:00:7F  A 1

20:00:00:25:B5:40:00:6F:20:00:00:25:B5:00:00:7F  B 0

20:00:00:25:B5:40:00:6F:20:00:00:25:B5:00:00:7F  A 0

20:00:00:25:B5:20:00:6F:20:00:00:25:B5:00:00:8F  B 1

20:00:00:25:B5:20:00:6F:20:00:00:25:B5:00:00:8F  A 1

20:00:00:25:B5:20:00:6F:20:00:00:25:B5:00:00:8F  B 0

20:00:00:25:B5:20:00:6F:20:00:00:25:B5:00:00:8F  A 0

Page 78: vnx doc

Device Name Logged In Registered Initiator Type Comm Path Failover ModeYes Yes CLARiioN Open Yes 4

Yes Yes CLARiioN Open Yes 4

Yes Yes CLARiioN Open Yes 4

Yes Yes CLARiioN Open Yes 4

Yes Yes CLARiioN Open Yes 4

Yes Yes CLARiioN Open Yes 4

Yes Yes CLARiioN Open Yes 4

Yes Yes CLARiioN Open Yes 4

Yes Yes CLARiioN Open Yes 4

Yes Yes CLARiioN Open Yes 4

Yes Yes CLARiioN Open Yes 4

Yes Yes CLARiioN Open Yes 4

Yes Yes CLARiioN Open Yes 4

Yes Yes CLARiioN Open Yes 4

Yes Yes CLARiioN Open Yes 4

Yes Yes CLARiioN Open Yes 4

sg7 

sg8 

sg6 

sg9 

PwrP:sdag 

PwrP:sdw 

PwrP:sdaq 

PwrP:sdm 

sg6 

sg9 

sg7 

sg8 

PwrP:sdw 

PwrP:sdaq 

PwrP:sdm 

PwrP:sdag 

Page 79: vnx doc

Unit SerialNumberArray

Array

Array

Array

Array

Array

Array

Array

Array

Array

Array

Array

Array

Array

Array

Array

Storage Groupdb3 

db3 

db3 

db3 

db1 

db1 

db1 

db1 

db4 

db4 

db4 

db4 

db2 

db2 

db2 

db2 

Page 80: vnx doc

LUN Mappings

Host IP Device Name Physical Drive Name

Logical Drive

InformationNone 

Page 81: vnx doc

Storage System Serial Number LUN Name LUN WWN

Page 82: vnx doc

Virtual Machines

Host IP Virtual Machine NameNone 

Page 83: vnx doc

Virtual Machine ID Guest HostnameNone 

Page 84: vnx doc

Guest Operating System

Guest Host

IP Addresses

Page 85: vnx doc

Virtual Machine LUN Mappings

Virtual Machine Name Virtual Machine ID

Virtual Machine

File Path TypeLUN Mapping NameNone 

Page 86: vnx doc

Disk Total Capacity Committed Space

Disk Mode LUN WWNs

Virtual Machine

(GB) (GB) Logical Drives