vulnerability survey format

Upload: eolbielen

Post on 03-Apr-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/29/2019 Vulnerability Survey Format

    1/8

    ANNEXURE-C : FORMAT FOR RECONNAISSANCE OF EXISTING

    BUILDINGS

    Building Identification

    GENERAL INFORMATION

    Building name:_________________________________________________

    Ownership: Public Private

    Owner name: __________________________________________________

    Address: ______________________________________________________

    _____________________________________________________________

    1. Building type

    Earthen building Stone in mud mortar

    Stone in cement mortar Brick masonry in mud mortar

    Brick masonry in cement mortar RCC Frame Building

    RCC Frame-shear wall BuildingMixed construction (specify):______________________________________

    2. Usage of the building

    Residential Business Offices Public Storage

    Others (specify):_______________________________

    3. Number of occupants (approximately):______________________

    4. Building location

    Isolated Internal End Corner

    5. Plan dimensions:

  • 7/29/2019 Vulnerability Survey Format

    2/8

    6. Total number of stories:

    7. Average inter-storey height:

    8. Construction age:

    9. Building construction quality

    Good Average Poor

    10. Building condition and maintenance

    Good Average Poor

    11. Building site located at

    Hill top High slope of hill Mild slope Plain

    River bed Others (specify):_________________________________

    12. Soil type

    Rock / Hard soil Medium soil Soft soil

    Reclaimed/filled land Partially filled land Loose sand

    Others (Specify): _____________________________

    13. Ground Water Table depth _______________________

    14. Gap between adjacent buildings: ________________________

    15. Plan of building:

    Symmetric Asymmetric

    16. Reentrant corner is:

    Less than 15% more than 15%

    17. Regularity in elevation:

    Regular irregular

  • 7/29/2019 Vulnerability Survey Format

    3/8

    If irregular, approximate Shape in elevation is of the type

    Percentage reduction/increase in dimensions: ________________________

    18. Location of staircase in building is

    Symmetric Asymmetric

    19. Staircase is

    Separated from main structure Connected to main structure

    If connected to main structure, it is

    Enclosed by rigid walls Not enclosed by rigid walls

    20. Basement provided: Yes No

    21. Overhang length: ________________________________________

    22 Parapet height: ___________

    Secured against falling Yes No

  • 7/29/2019 Vulnerability Survey Format

    4/8

    MASONRY BUILDING

    1. Type of construction

    Engineered construction Non-Engineered construction

    2. Layout of masonry (Tick in case of stone masonry)

    Random rubble Half dressed stone Ashlar masonry

    3. Through stones (Tick in case of random rubble masonry)

    Provided Not provided

    4. Earthquake resistant features provided in the buildingLintel band Roof band Plinth band

    Vertical reinforcement at

    Corners Junctions Jambs of openings

    5. Minimum pier dimensions: ___________________________________

    6. Existence of floating walls

    Yes No

    7. Foundation type

    Strip foundation Raft foundation Pile foundation

    Others (specify):_____________________________________

    8. Foundation material used for construction

    Stone Brick Cement concrete RCC

    9. Percentage openings in main walls: ________________________

  • 7/29/2019 Vulnerability Survey Format

    5/8

    10. Thickness of

    Exterior wall _________mm Interior wall _________mm

    11. Roof type

    Flat roof Sloping roof Hipped Roof

    12. If sloping provided, then

    Ties provided Yes No

    Bracing provided Yes No

    Roof and Gable band provided Yes No

    13. Roofing material used

    RCC slab Tiles Corrugated iron sheeting

    Asbestos sheeting Others, specify____________________

    14. Inspection accuracy

    From outside only Contacted owner also

    Partial Complete

    Names of the surveyors: Date:

    1. 2.

  • 7/29/2019 Vulnerability Survey Format

    6/8

    RCC BUILDING

    1. Irregularities in structure

    Open ground floor Floating columns Mezzanine floor

    Heavy mass at roof Partially filled panels Floating shear walls

    Any other(Specify): _______________________________________________

    _______________________________________________________________

    2. Designed by

    Architect Structural engineer Mason

    3. Enhanced ductility design: Yes No

    4. Column size at ground floor: __________________

    5. Beam size: ________________________________

    6. Spans between columns: _____________________

    7. Shear wall(s) provided: Yes No

    If provided, Symmetrically asymmetrically

    Thickness of shear wall ________________________________

    8. Infill type

    Brick masonry Stone masonry Solid concrete blocks

    Hollow concrete blocks Timber

    Any other(Specify): ___________________________________

    Thickness of Infill

    Exterior________________ Interior________________

    9. Basement Provided: Yes No

  • 7/29/2019 Vulnerability Survey Format

    7/8

    10. Inspection accuracy

    From outside only Contacted owner also

    Partial Complete

    Names of the surveyors: Date:

    1. 2.

    Sketch of building plan

  • 7/29/2019 Vulnerability Survey Format

    8/8

    Sketch of building elevation